Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Graefes Arch Clin Exp Ophthalmol ; 261(7): 2049-2059, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36729331

RESUMEN

PURPOSE: During their initial management, some macular melanocytic lesions can be closely monitored to wait for a documented growth before advocating a treatment by irradiation. However, the visual outcomes of this strategy have not yet been assessed. This study compares the visual outcomes of macular melanocytic lesions that underwent delayed proton beam therapy (PBT) after an initial observation to those treated early. METHODS: A total of 162 patients with suspicious melanocytic lesions whose margins were located within 3 mm of the fovea were recruited from two French ocular oncology centers. RESULTS: Overall, 82 patients treated with PBT within 4 months after the initial visit (early PBT group) were compared to 24 patients treated with delayed PBT (delayed PBT group) and 56 patients not treated with PBT (observation group). Visual acuity was not significantly different between baseline and last visit in the observation group (p = 0.325). Between baseline and last visit, the median [IQR] loss in visual acuity was significant in both the early (0.7 [0.2; 1.8], p < 0.001) and the delayed (0.5 [0.2; 1.5], p < 0.001) PBT groups. After irradiation, there was no significant difference between the early and delayed PBT groups for visual loss (p = 0.575), diameter reduction (p = 0.190), and thickness lowering (p = 0.892). In multivariate analysis, history of diabetes mellitus and Bruch's membrane rupture remained significantly associated with greater visual loss (p = 0.036 and p = 0.002, respectively). CONCLUSION: For small lesions in which there is no clear diagnosis of malignant melanoma, an initial close monitoring to document tumor growth does not impact visual prognosis, despite the potential complications associated with the untreated tumor. However, the survival should remain the main outcome of the treatment of these lesions.


Asunto(s)
Melanoma , Terapia de Protones , Neoplasias de la Úvea , Humanos , Terapia de Protones/efectos adversos , Neoplasias de la Úvea/diagnóstico , Estudios Retrospectivos , Melanoma/diagnóstico , Melanoma/radioterapia , Melanocitos/patología
2.
Support Care Cancer ; 30(10): 8377-8389, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-35513755

RESUMEN

INTRODUCTION: Despite reduction of xerostomia with intensity-modulated compared to conformal X-ray radiotherapy, radiation-induced dental complications continue to occur. Proton therapy is promising in head and neck cancers to further reduce radiation-induced side-effects, but the optimal dental management has not been defined. MATERIAL AND METHODS: Dental management before proton therapy was assessed compared to intensity-modulated radiotherapy based on a bicentric experience, a literature review and illustrative cases. RESULTS: Preserved teeth frequently contain metallic dental restorations (amalgams, crowns, implants). Metals blur CT images, introducing errors in tumour and organ contour during radiotherapy planning. Due to their physical interactions with matter, protons are more sensitive than photons to tissue composition. The composition of restorative materials is rarely documented during radiotherapy planning, introducing dose errors. Manual artefact recontouring, metal artefact-reduction CT algorithms, dual or multi-energy CT and appropriate dose calculation algorithms insufficiently compensate for contour and dose errors during proton therapy. Physical uncertainties may be associated with lower tumour control probability and more side-effects after proton therapy. Metal-induced errors should be quantified and removal of metal restorations discussed on a case by case basis between dental care specialists, radiation oncologists and physicists. Metallic amalgams can be replaced with water-equivalent materials and crowns temporarily removed depending on rehabilitation potential, dental condition and cost. Implants might contraindicate proton therapy if they are in the proton beam path. CONCLUSION: Metallic restorations may more severely affect proton than photon radiotherapy quality. Personalized dental care prior to proton therapy requires multidisciplinary assessment of metal-induced errors before choice of conservation/removal of dental metals and optimal radiotherapy.


Asunto(s)
Atención Odontológica , Neoplasias de Cabeza y Cuello , Neoplasias de Cabeza y Cuello/radioterapia , Humanos , Metales , Terapia de Protones/efectos adversos , Traumatismos por Radiación , Radioterapia de Intensidad Modulada/efectos adversos , Agua
3.
Retina ; 42(10): 1995-2003, 2022 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-35976250

RESUMEN

PURPOSE: To evaluate choriocapillaris alterations following proton beam therapy irradiation using swept-source optical coherence tomography-angiography, and to assess their correlation with the grade of radiation retinopathy (RR). METHODS: Eyes with uveal melanoma evaluated before and after irradiation with proton beam therapy were included, as well as the healthy fellow eye. The gradation of RR was based on a previously published classification. Choriocapillaris flow voids area was analyzed using Phansalkar thresholding. Retinal vascularization was described by foveal avascular zone (FAZ) perimeter, FAZ area, FAZ circularity index, and percentage of nonperfusion area (PAN) in the superficial capillary plexus (SCP) or deep capillary plexus. RESULTS: A total of 157 eyes of 83 patients were analyzed. Overall, there was a significant difference between the control group, the uveal melanoma before proton beam therapy group, and the grades of RR in the uveal melanoma after proton beam therapy group for FAZ perimeter ( P < 0.001), FAZ area ( P < 0.001), FAZ-circularity index ( P < 0.001), PAN-SCP ( P < 0.001), PAN-deep capillary plexus ( P < 0.001), and choriocapillaris flow voids area ( P < 0.001). Moreover, choriocapillaris flow voids area was significantly increased in the early stages of RR ( P = 0.003) and was further significantly correlated with FAZ perimeter ( P < 0.001), FAZ area ( P < 0.001), FAZ-circularity index ( P = 0.010), PAN-SCP ( P < 0.001), and PAN-deep capillary plexus ( P < 0.001). CONCLUSION: Quantitative optical coherence tomography-angiography alterations in the choriocapillaris microvascularization are an early biomarker of RR and are correlated to the severity of the disease.


Asunto(s)
Traumatismos por Radiación , Enfermedades de la Retina , Coroides , Angiografía con Fluoresceína , Humanos , Melanoma , Traumatismos por Radiación/diagnóstico por imagen , Traumatismos por Radiación/etiología , Enfermedades de la Retina/diagnóstico , Enfermedades de la Retina/etiología , Vasos Retinianos , Tomografía de Coherencia Óptica , Neoplasias de la Úvea
4.
Ophthalmology ; 128(1): 152-161, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32574763

RESUMEN

PURPOSE: Normal tissue complication probability (NTCP) models could aid the understanding of dose dependence of radiation-induced toxicities after eye-preserving radiotherapy of choroidal melanomas. We performed NTCP-modeling and established dose-response relationships for visual acuity (VA) deterioration and common late complications after treatments with proton therapy (PT). DESIGN: Retrospective study from single, large referral center. PARTICIPANTS: We considered patients from Nice, France, diagnosed with choroidal melanoma and treated primarily with hypofractionated PT (52 Gy physical dose in 4 fractions). Complete VA deterioration information was available for 1020 patients, and complete information on late complications was available for 991 patients. METHODS: Treatment details, dose-volume histograms (DVHs) for relevant anatomic structures, and patient and tumor characteristics were available from a dedicated ocular database. Least absolute shrinkage and selection operator (LASSO) variable selection was used to identify variables with the strongest impact on each end point, followed by multivariate Cox regressions and logistic regressions to analyze the relationships among dose, clinical characteristics, and clinical outcomes. MAIN OUTCOME MEASURES: Dose-response relationship for VA deterioration and late complications. RESULTS: Dose metrics for several structures (i.e., optic disc, macula, retina, globe, lens, ciliary body) correlated with clinical outcome. The near-maximum dose to the macula showed the strongest correlation with VA deterioration. The near-maximum dose to the retina was the only variable with clear impact on the risk of maculopathy, the dose to 20% of the optic disc had the largest impact on optic neuropathy, dose to 20% of cornea had the largest impact on neovascular glaucoma, and dose to 20% of the ciliary body had the largest impact on ocular hypertension. The volume of the ciliary body receiving 26 Gy was the only variable associated with the risk of cataract, and the volume of retina receiving 52 Gy was associated with the risk of retinal detachment. Optic disc-to-tumor distance was the only variable associated with dry eye syndrome in the absence of DVH for the lachrymal gland. CONCLUSIONS: VA deterioration and specific late complications demonstrated dependence on dose delivered to normal structures in the eye after PT for choroidal melanoma. VA deterioration depended on dose to a range of structures, whereas more specific complications were related to dose metrics for specific structures.


Asunto(s)
Neoplasias de la Coroides/radioterapia , Cristalino/patología , Mácula Lútea/patología , Melanoma/radioterapia , Disco Óptico/patología , Terapia de Protones/métodos , Agudeza Visual , Anciano , Neoplasias de la Coroides/diagnóstico , Femenino , Estudios de Seguimiento , Humanos , Cristalino/efectos de la radiación , Mácula Lútea/efectos de la radiación , Masculino , Melanoma/diagnóstico , Persona de Mediana Edad , Disco Óptico/efectos de la radiación , Dosificación Radioterapéutica , Estudios Retrospectivos
5.
Retina ; 41(2): 277-286, 2021 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-32404844

RESUMEN

PURPOSE: The aim of this study was to compare the functional and anatomical effectiveness of photodynamic therapy (PDT) versus proton beam therapy (PBT) in a real-life setting for the treatment of circumscribed choroidal hemangioma. METHODS: A total of 191 patients with a diagnosis of circumscribed choroidal hemangioma and treated by PBT or PDT were included for analyses. RESULTS: The 119 patients (62.3%) treated by PDT were compared with the 72 patients treated by PBT. The final best-corrected visual acuity did not differ significantly between the two groups (P = 0.932) and final thickness was lower in the PBT compared with the PDT group (P = 0.001). None of the patients treated by PBT needed second-line therapy. In comparison, 53 patients (44.5%) initially treated by PDT required at least one other therapy and were associated with worse final best-corrected visual acuity (P = 0.037). In multivariate analysis, only an initial thickness greater than 3 mm remained significant (P = 0.01) to predict PDT failure with an estimated odds ratio of 2.72, 95% confidence interval (1.25-5.89). CONCLUSION: Photodynamic therapy and PBT provide similar anatomical and functional outcomes for circumscribed choroidal hemangioma ≤3 mm, although multiple sessions are sometimes required for PDT. For tumors >3 mm, PBT seems preferable because it can treat the tumor in only 1 session with better functional and anatomical outcomes.


Asunto(s)
Neoplasias de la Coroides/tratamiento farmacológico , Coroides/patología , Hemangioma/tratamiento farmacológico , Fotoquimioterapia/métodos , Porfirinas/uso terapéutico , Verteporfina/uso terapéutico , Agudeza Visual , Neoplasias de la Coroides/diagnóstico , Femenino , Angiografía con Fluoresceína/métodos , Estudios de Seguimiento , Hemangioma/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Fármacos Fotosensibilizantes/uso terapéutico , Protones , Estudios Retrospectivos , Tomografía de Coherencia Óptica , Resultado del Tratamiento
6.
Nanomedicine ; 23: 102084, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31454552

RESUMEN

Although chemically synthesized ferro/ferrimagnetic nanoparticles have attracted great attention in cancer theranostics, they lack radio-enhancement efficacy due to low targeting and internalization ability. Herein, we investigated the potential of RGD-tagged magnetosomes, bacterial biogenic magnetic nanoparticles naturally coated with a biological membrane and genetically engineered to express an RGD peptide, as tumor radioenhancers for conventional radiotherapy and proton therapy. Although native and RGD-magnetosomes similarly enhanced radiation-induced damage to plasmid DNA, RGD-magnetoprobes were able to boost the efficacy of radiotherapy to a much larger extent than native magnetosomes both on cancer cells and in tumors. Combined to magnetosomes@RGD, proton therapy exceeded the efficacy of X-rays at equivalent doses. Also, increased secondary emissions were measured after irradiation of magnetosomes with protons versus photons. Our results indicate the therapeutic advantage of using functionalized magnetoparticles to sensitize tumors to both X-rays and protons and strengthen the case for developing biogenic magnetoparticles for multimodal nanomedicine in cancer therapy.


Asunto(s)
Magnetosomas/química , Magnetospirillum/química , Neoplasias Experimentales/radioterapia , Oligopéptidos , Fármacos Sensibilizantes a Radiaciones , Animales , Línea Celular Tumoral , Femenino , Humanos , Ratones , Ratones Endogámicos BALB C , Ratones Desnudos , Neoplasias Experimentales/metabolismo , Neoplasias Experimentales/patología , Oligopéptidos/química , Oligopéptidos/farmacología , Terapia de Protones , Fármacos Sensibilizantes a Radiaciones/química , Fármacos Sensibilizantes a Radiaciones/farmacología , Terapia por Rayos X
7.
Graefes Arch Clin Exp Ophthalmol ; 257(6): 1309-1318, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30919076

RESUMEN

BACKGROUND: The management of conjunctival melanoma is challenging and frequently ends in exenteration. The aim of this retrospective study was to evaluate the long-term results of proton beam radiation with regard to various clinical parameters. METHODS: Eighty-nine patients with extended conjunctival melanoma (≥T2) and multifocal bulbar located tumors (T1c/d) were treated consecutively with proton radiotherapy (dose 45 Gy). The following parameters were assessed: TNM stage, tumor origin, local recurrence, performance of exenteration, occurrence of metastases, overall survival, and potential complications. A time-to-event analysis was preformed to the primary endpoints: relapse, metastasis, exenteration, and death by use of Kaplan-Meier cumulative survival estimates and Cox proportional hazards regression that provides hazard ratios and 95% confidence intervals. RESULTS: The median follow-up time was 4.2 years (max. 21.7 years). Local recurrence and metastatic disease occurred in 33% and 16% of patients, respectively. Exenteration-free survival and overall survival tended to be worse in T3 melanoma. No association between tumor origin and local recurrence, metastatic disease, or overall survival was observed. Main complications after proton radiotherapy were sicca-syndrome (30%), secondary glaucoma (11%), and limbal stem cell deficiency (8%). CONCLUSIONS: In summary, proton radiotherapy in conjunctival melanoma is an effective alternative to exenteration, with a 5-year cumulative probability of eye preservation of 69%.


Asunto(s)
Conjuntiva/patología , Neoplasias de la Conjuntiva/radioterapia , Melanoma/radioterapia , Terapia de Protones/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Neoplasias de la Conjuntiva/patología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Melanoma/patología , Persona de Mediana Edad , Estadificación de Neoplasias , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
8.
J Radiol Prot ; 39(1): 250-278, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30721148

RESUMEN

Ambient dose equivalent measurements with radiation protection instruments are associated to large uncertainties, mostly due to the energy dependence of the instrument response and to the dissimilarity between the spectra of the standard calibration source and the workplace field. The purpose of this work is to evaluate its impact on the performance of area and environmental detectors in the proton therapy environment, and to provide practical solutions whenever needed and possible. The study was carried out at the Centre Antoine Lacassagne (CAL) proton therapy site, and included a number of commercially available area detectors and a home-made environmental thermoluminescent dosimeter based on a polyethylene moderator loaded with TLD600H/TLD700H pairs. Monte Carlo simulations were performed with MCNP to calculate, first, missing or partially lacking instrument responses, covering the range of energies involved in proton therapy. Second, neutron and gamma spectra were computed at selected positions in and outside the CAL proton therapy bunkers. Appropriate correction factors were then derived for each detector, workplace location and calibration radionuclide source, which amounts to up to 1.9 and 1.5 for neutron and photon area detectors, respectively, and suggest that common ambient dose equivalent instruments might not meet IEC requirements. The TLD environmental system was calibrated in situ and appropriate correction factors were applied to account for the cosmic spectra. Measurements performed with this system from 2014 to 2017 around the installation were consistent with reference natural background dose data and with pre-operational levels registered at the site before the construction of the building in 1988, showing thus no contribution from the site clinical activities. An in situ verification procedure for the radiation protection instruments was also implemented in 2016 at the low energy treatment room using the QA beam reference conditions. The method presents main methodological, practical and economic advantages over external verifications.


Asunto(s)
Rayos gamma , Neutrones , Terapia de Protones , Exposición a la Radiación/análisis , Monitoreo de Radiación/métodos , Protección Radiológica , Calibración , Simulación por Computador
9.
Ophthalmology ; 125(4): 606-614, 2018 04.
Artículo en Inglés | MEDLINE | ID: mdl-29128229

RESUMEN

PURPOSE: To report on the clinical characteristics and outcomes for patients with iris melanoma using proton therapy. DESIGN: Retrospective study. PARTICIPANTS: One hundred seven patients with iris melanoma from 3 regional ophthalmologic centers. METHODS: A retrospective study was conducted for iris melanoma patients from 3 regional ophthalmologic centers referred to and treated at a single proton therapy facility between 1996 and 2015. MAIN OUTCOME MEASURES: At each follow-up visit, examinations included measurement of best-corrected VA, slit-lamp, examination, indirect ophthalmoscopy, and ultrasound biomicroscopy. RESULTS: With a median follow-up of 49.5 months, 5 of 107 patients experienced a local relapse within a median of 36.3 months. The cumulative incidence of relapse was 7.5% at 5 years. All 5 patients showed involvement of the iridocorneal angle (P = 0.056). Diffuse iris melanoma showed a higher risk of relapse (P = 0.044). Four patients showed out-of-field relapse and 1 showed angular relapse. Three patients were retreated with proton therapy, whereas 2 other patients, one with T1b disease and another with diffuse T3 disease, underwent secondary enucleation. None of the patients experienced metastases nor died of iris melanoma. Vision improved in 59.4% of patients (n = 60/101). However, cataracts occurred in 57.4% of the 54 patients (n = 31) without cataract or implant at diagnosis. Secondary glaucoma was reported in 7.6% of the patients (n = 8), uveitis in 4.7% (n = 5), and hyphema in 3.7% (n = 4). All but 5 cases of complications were mild, transient, and not sight limiting after treatment. Five cases of glaucoma, including 1 with uveitis, were severe and associated with visual deterioration. CONCLUSIONS: Proton therapy showed efficacy and limited morbidity in iris melanomas.


Asunto(s)
Neoplasias del Iris/radioterapia , Melanoma/radioterapia , Terapia de Protones/métodos , Adulto , Anciano , Femenino , Estudios de Seguimiento , Humanos , Neoplasias del Iris/diagnóstico , Neoplasias del Iris/patología , Masculino , Melanoma/diagnóstico , Melanoma/patología , Microscopía Acústica , Persona de Mediana Edad , Recurrencia Local de Neoplasia/patología , Oftalmoscopía , Estudios Retrospectivos , Microscopía con Lámpara de Hendidura , Agudeza Visual
10.
Graefes Arch Clin Exp Ophthalmol ; 252(9): 1515-21, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25038910

RESUMEN

BACKGROUND: To report the clinical features and outcomes of iris melanomas treated by proton beam therapy. MATERIALS AND METHODS: A retrospective study was conducted at the Croix-Rousse University Hospital of Lyon, Department of Ophthalmology, in 36 patients treated by proton beam therapy for presumed (n = 29) and confirmed (n = 7) iris melanomas between July 1997 and October 2010. Ciliary body melanomas with iris involvement were excluded. The patients' mean age was 54.4 years (range, 22-82 years). The average tumor diameter was 3.8 mm (range, 2.5-8.0). The iridocorneal angle was invaded by the tumor in 47% of cases (n = 17), the ciliary body in 17% of cases (n = 6), and the sclera in 3% (n = 1). Raised intraocular pressure was present before treatment in 11.1 % of cases (n = 4). Tumor biopsy was performed in 19% of cases (n = 7). Four patients had undergone an initial incomplete surgical excision of tumor before radiotherapy. Surgical preparation of the eye with tantalum ring positioning had been performed in all cases 3-4 weeks before irradiation. The prescribed dose was 60 Cobalt Gray Equivalent (CGE) of proton beam radiotherapy delivered in four fractions on four consecutive days. RESULTS: The median follow-up was 50 months (mean 60.5, range 15-136). One patient (2.7%) was lost to follow-up. None of the patients showed tumor progression, local recurrence, or metastasis. None of the patients required secondary enucleation. Cataract was developed in 62% of patients, glaucoma in two cases (6%) after irradiation, and hyphema with the aggravation of pre-existing glaucoma in one patient. No patients developed neovascular glaucoma. CONCLUSIONS: Proton beam therapy appears to be the treatment of choice for the conservative treatment of iris melanomas with excellent tumor control and an acceptable rate of complications. Longer follow-up studies on a larger series is necessary to consolidate these results.


Asunto(s)
Neoplasias del Iris/radioterapia , Melanoma/radioterapia , Terapia de Protones , Adulto , Anciano , Anciano de 80 o más Años , Color del Ojo , Femenino , Estudios de Seguimiento , Humanos , Neoplasias del Iris/patología , Masculino , Melanoma/patología , Persona de Mediana Edad , Dosificación Radioterapéutica , Resultado del Tratamiento , Adulto Joven
11.
J Phys Condens Matter ; 36(24)2024 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-38447159

RESUMEN

Radioluminescent silica-based fiber dosimeters offer great advantages for designing miniaturized realtime sensors for high dose-rate dosimetry. Rise and fall kinetics of their response must be properly understood to better assess their performances in terms of measurement speed and repeatability. A standard model of radioluminescence (RL) has already been quantitatively validated for doped silica glasses, but beyond conclusive comparisons with specific experiments, a comprehensive understanding of the processes and parameters determining transient and equilibrium kinetics of RL is still lacking. We analyze in detail the kinetics inherent in the standard RL model. Several asymptotical regimes in the RL growth are demonstrated in the case of a pristine sample (succesive quadratic, linear and power-law time dependencies before the plateau is reached). We show how this situation is modified when a pre-irradiation partly fills traps beforehand. RL growth is then greatly accelerated because of the pre-formation of recombination centers (RCs) from dopant ions, but not due to pre-filling of trapping levels. In all cases, the RL intensity eventually tends to a constant level equal to the pair generation rate, long before all carrier densities themselves reach equilibrium. This occurs late under irradiation, when deep traps get to saturation. The fraction of dopants converted into RCs is then 'frozen' at a lower level the smaller the density of deep traps. Controlling RL kinetics through the engineering of material traps is not an option. Pre-irradiation appears to be the simplest way to obtain accelerated and repeatable kinetics.

12.
Phys Med Biol ; 69(4)2024 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-38211314

RESUMEN

Objective.Determining and verifying the number of monitor units is crucial to achieving the desired dose distribution in radiotherapy and maintaining treatment efficacy. However, current commercial treatment planning system(s) dedicated to ocular passive eyelines in proton therapy do not provide the number of monitor units for patient-specific plan delivery. Performing specific pre-treatment field measurements, which is time and resource consuming, is usually gold-standard practice. This proof-of-concept study reports on the development of a multi-institutional-based generalized model for monitor units determination in proton therapy for eye melanoma treatments.Approach.To cope with the small number of patients being treated in proton centers, three European institutes participated in this study. Measurements data were collected to address output factor differences across the institutes, especially as function of field size, spread-out Bragg peak modulation width, residual range, and air gap. A generic model for monitor units prediction using a large number of 3748 patients and broad diversity in tumor patterns, was evaluated using six popular machine learning algorithms: (i) decision tree; (ii) random forest, (iii) extra trees, (iv) K-nearest neighbors, (v) gradient boosting, and (vi) the support vector regression. Features used as inputs into each machine learning pipeline were: Spread-out Bragg peak width, range, air gap, fraction and calibration doses. Performance measure was scored using the mean absolute error, which was the difference between predicted and real monitor units, as collected from institutional gold-standard methods.Main results.Predictions across algorithms were accurate within 3% uncertainty for up to 85.2% of the plans and within 10% uncertainty for up to 98.6% of the plans with the extra trees algorithm.Significance.A proof-of-concept of using machine learning-based generic monitor units determination in ocular proton therapy has been demonstrated. This could trigger the development of an independent monitor units calculation tool for clinical use.


Asunto(s)
Neoplasias del Ojo , Melanoma , Terapia de Protones , Humanos , Terapia de Protones/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Aprendizaje Automático , Protones , Dosificación Radioterapéutica , Neoplasias del Ojo/radioterapia
13.
Phys Med Biol ; 69(8)2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38252970

RESUMEN

Objective. Ionization chambers, mostly used for beam calibration and for reference dosimetry, can show high recombination effects in pulsed high dose rate proton beams. The aims of this paper are: first, to characterize the linearity response of newly designed asymmetrical beam monitor chambers (ABMC) in a 100-226 MeV pulsed high dose rate per pulse scanned proton beam; and secondly, to calibrate the ABMC with a PPC05 (IBA Dosimetry) plane parallel ionization chamber and compare to calibration with a home-made Faraday cup (FC).Approach. The ABMC response linearity was evaluated with both the FC and a PTW 60019 microDiamond detector. Regarding ionometry-based ABMC calibration, recombination factors were evaluated theoretically, then numerically, and finally experimentally measured in water for a plane parallel ionization chamber PPC05 (IBA Dosimetry) throughkssaturation curves. Finally, ABMC calibration was also achieved with FC and compared to the ionometry method for 7 energies.Main results. Linearity measurements showed that recombination losses in the new ABMC design were well taken into account for the whole range of the machine dose rates. The two-voltage-method was not suitable for recombination correction, but Jaffé's plots analysis was needed, emphasizing the current IAEA TRS-398 reference protocol limitations. Concerning ABMC calibration, FC based absorbed dose estimation and PPC05-based absorbed dose estimation differ by less than 6.3% for the investigated energies.Significance.So far, no update on reference dosimetry protocols is available to estimate the absorbed dose in ionization chambers for clinical high dose rate per pulse pulsed scanned proton beams. This work proposes a validation of the new ABMC design, a method to take into account the recombination effect for ionometry-based ABMC calibration and a comparison with FC dose estimation in this type of proton beams.


Asunto(s)
Protones , Radiactividad , Ciclotrones , Calibración , Radiometría/métodos , Agua
14.
Phys Med Biol ; 68(12)2023 06 13.
Artículo en Inglés | MEDLINE | ID: mdl-37220766

RESUMEN

Objective.The range uncertainty in proton radiotherapy is a limiting factor to achieve optimum dose conformity to the tumour volume. Ionoacoustics is a promising approach forin siturange verification, which would allow to reduce the size of the irradiated volume relative to the tumour volume. The energy deposition of a pulsed proton beam leads to an acoustic pressure wave (ionoacoustics), the detection of which allows conclusion about the distance between the Bragg peak and the acoustic detector. This information can be transferred into a co-registered ultrasound image, marking the Bragg peak position relative to the surrounding anatomy.Approach.A CIRS 3D abdominal phantom was irradiated with 126 MeV protons at a clinical proton therapy centre. Acoustic signals were recorded on the beam axis distal to the Bragg peak with a Cetacean C305X hydrophone. The ionoacoustic measurements were processed with a correlation filter using simulated filter templates. The hydrophone was rigidly attached to an ultrasound device (Interson GP-C01) recording ultrasound images of the irradiated region.Main results.The time of flight obtained from ionoacoustic measurements were transferred to an ultrasound image by means of an optoacoustic calibration measurement. The Bragg peak position was marked in the ultrasound image with a statistical uncertainty ofσ= 0.5 mm of 24 individual measurements depositing 1.2 Gy at the Bragg peak. The difference between the evaluated Bragg peak position and the one obtained from irradiation planning (1.0 mm) is smaller than the typical range uncertainty (≈4 mm) at the given penetration depth (10 cm).Significance.The measurements show that it is possible to determine the Bragg peak position of a clinical proton beam with submillimetre precision and transfer the information to an ultrasound image of the irradiated region. The dose required for this is smaller than that used for a typical irradiation fraction.


Asunto(s)
Terapia de Protones , Protones , Terapia de Protones/métodos , Acústica , Sonido , Fantasmas de Imagen , Dosificación Radioterapéutica , Método de Montecarlo
15.
Int J Radiat Oncol Biol Phys ; 117(2): 357-369, 2023 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-37257661

RESUMEN

PURPOSE: Patients with large uveal melanomas are at major risk of liver metastases. Some patients are reluctant to undergo the standard treatment (ie, immediate enucleation). Proton therapy yields 5-year local control rates and eyeball retention of >85% and ≈20% in large uveal melanomas. Patients with T3/T4 uveal melanomas refusing enucleation were randomized between standard 4 to 13 Gy-fraction or moderately hypofractionated 8 to 6.5 Gy-fraction proton therapy. The main endpoint was the 2-year local recurrence-free survival without enucleation. METHODS AND MATERIALS: A single-masked 1:2 randomized phase 2 trial was conducted between 2015 and 2017 with planned endoresection and distance to the posterior pole as strata. Local events were defined as local relapse, or enucleation due to complications or relapse. RESULTS: The 32 patients, with a mean age of 64 years, had T3/4 (N = 17/15), M1 (N = 2) uveal melanomas, of mean tumor diameter and thickness of 16.5 mm and 9.1 mm, and of posterior location in 56.5%. Median follow-up was 56.7 months. The 2-year local recurrence-free survival rate without enucleation was 79% (95% confidence interval, 65%-96%), similar in both arms. There were 9 enucleations, 3 at relapse and 6 for toxicities. Twelve patients had distant metastases. The 2-year-overall survival was 72% (95% confidence interval, 58%-89%). At baseline, visual acuity by average logarithm value of the minimum angle of resolution was 0.68 and 0.70 in the standard and experimental arms, and at last follow-up 2 and 1.7, with mean differences of 1.44 and 1.01, respectively (P = .39). CONCLUSION: An 8-times 6.5 Gy scheme is feasible without deteriorating local control and with similar toxicity rates in patients with large uveal melanomas. Larger studies incorporating adjuvant treatments are warranted.


Asunto(s)
Melanoma , Terapia de Protones , Neoplasias de la Úvea , Humanos , Persona de Mediana Edad , Terapia de Protones/efectos adversos , Recurrencia Local de Neoplasia , Neoplasias de la Úvea/radioterapia , Neoplasias de la Úvea/patología , Melanoma/radioterapia , Melanoma/patología
16.
Sci Rep ; 13(1): 3609, 2023 Mar 03.
Artículo en Inglés | MEDLINE | ID: mdl-36869125

RESUMEN

We recently proposed a new approach for the real-time monitoring of particle therapy treatments with the goal of achieving high sensitivities on the particle range measurement already at limited counting statistics. This method extends the Prompt Gamma (PG) timing technique to obtain the PG vertex distribution from the exclusive measurement of particle Time-Of-Flight (TOF). It was previously shown, through Monte Carlo simulation, that an original data reconstruction algorithm (Prompt Gamma Time Imaging) allows to combine the response of multiple detectors placed around the target. The sensitivity of this technique depends on both the system time resolution and the beam intensity. At reduced intensities (Single Proton Regime-SPR), a millimetric proton range sensitivity can be achieved, provided the overall PG plus proton TOF can be measured with a 235 ps (FWHM) time resolution. At nominal beam intensities, a sensitivity of a few mm can still be obtained by increasing the number of incident protons included in the monitoring procedure. In this work we focus on the experimental feasibility of PGTI in SPR through the development of a multi-channel, Cherenkov-based PG detector with a targeted time resolution of 235 ps (FWHM): the TOF Imaging ARrAy (TIARA). Since PG emission is a rare phenomenon, TIARA design is led by the concomitant optimisation of its detection efficiency and Signal to Noise Ratio (SNR). The PG module that we developed is composed of a small PbF[Formula: see text] crystal coupled to a silicon photoMultiplier to provide the time stamp of the PG. This module is currently read in time coincidence with a diamond-based beam monitor placed upstream the target/patient to measure the proton time of arrival. TIARA will be eventually composed of 30 identical modules uniformly arranged around the target. The absence of a collimation system and the use of Cherenkov radiators are both crucial to increase the detection efficiency and the SNR, respectively. A first prototype of the TIARA block detector was tested with 63 MeV protons delivered from a cyclotron: a time resolution of 276 ps (FWHM) was obtained, resulting in a proton range sensitivity of 4 mm at 2[Formula: see text] with the acquisition of only 600 PGs. A second prototype was also evaluated with 148 MeV protons delivered from a synchro-cyclotron obtaining a time resolution below 167 ps (FWHM) for the gamma detector. Moreover, using two identical PG modules, it was shown that a uniform sensitivity on the PG profiles would be achievable by combining the response of gamma detectors uniformly distributed around the target. This work provides the experimental proof-of-concept for the development of a high sensitivity detector that can be used to monitor particle therapy treatments and potentially act in real-time if the irradiation does not comply to treatment plan.

17.
Ophthalmologica ; 227(4): 190-6, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22269846

RESUMEN

PURPOSE: To evaluate survival and clinical outcome for patients with a large uveal melanoma treated by either enucleation or proton beam radiotherapy (PBRT). PROCEDURES: This retrospective non-randomized study evaluated 132 consecutive patients with T3 and T4 choroidal melanoma classified according to TNM stage grouping. RESULTS: Cumulative all-cause mortality, melanoma-related mortality and metastasis-free survival were not statistically different between the two groups (log-rank test, p = 0.56, p = 0.99 and p = 0.25, respectively). Eye retention of the tumours treated with PBRT at 5 years was 74% (SD 6.2%). In these patients at diagnosis, 73% of eyes had a best-corrected visual acuity (BCVA) of 0.1 or better. After 12 and 60 months, BCVA of 0.1 or better was observed in 47.5 and 32%, respectively. CONCLUSION AND MESSAGE: Although enucleation is the most common primary treatment for large uveal melanomas, PBRT is an eye-preserving option that may be considered for some patients.


Asunto(s)
Neoplasias de la Coroides/radioterapia , Neoplasias de la Coroides/cirugía , Enucleación del Ojo , Melanoma/radioterapia , Melanoma/cirugía , Radioterapia de Alta Energía , Anciano , Causas de Muerte , Neoplasias de la Coroides/mortalidad , Neoplasias de la Coroides/patología , Femenino , Estudios de Seguimiento , Humanos , Masculino , Melanoma/mortalidad , Melanoma/patología , Persona de Mediana Edad , Estadificación de Neoplasias , Protones , Estudios Retrospectivos , Tasa de Supervivencia , Resultado del Tratamiento , Agudeza Visual/fisiología
19.
Cancers (Basel) ; 14(5)2022 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-35267502

RESUMEN

The eye is an exemplarily challenging organ to treat when considering ocular tumors. It is at the crossroads of several major aims in oncology: tumor control, organ preservation, and functional outcomes including vision and quality of life. The proximity between the tumor and organs that are susceptible to radiation damage explain these challenges. Given a high enough dose of radiation, virtually any cancer will be destroyed with radiotherapy. Yet, the doses inevitably absorbed by normal tissues may lead to complications, the likelihood of which increases with the radiation dose and volume of normal tissues irradiated. Precision radiotherapy allows personalized decision-making algorithms based on patient and tumor characteristics by exploiting the full knowledge of the physics, radiobiology, and the modifications made to the radiotherapy equipment to adapt to the various ocular tumors. Anticipation of the spectrum and severity of radiation-induced complications is crucial to the decision of which technique to use for a given tumor. Radiation can damage the lacrimal gland, eyelashes/eyelids, cornea, lens, macula/retina, optic nerves and chiasma, each having specific dose-response characteristics. The present review is a report of non-cancer effects that may occur following ionizing irradiation involving the eye and orbit and their specific patterns of toxicity for a given radiotherapy modality.

20.
Phys Med Biol ; 67(20)2022 10 03.
Artículo en Inglés | MEDLINE | ID: mdl-36070743

RESUMEN

Objective.Image guidance and precise irradiation are fundamental to ensure the reliability of small animal oncology studies. Accurate positioning of the animal and the in-beam monitoring of the delivered radio-therapeutic treatment necessitate several imaging modalities. In the particular context of proton therapy with a pulsed beam, information on the delivered dose can be retrieved by monitoring the thermoacoustic waves resulting from the brief and local energy deposition induced by a proton beam (ionoacoustics). The objective of this work was to fabricate a multimodal phantom (x-ray, proton, ultrasound, and ionoacoustics) allowing for sufficient imaging contrast for all the modalities.Approach.The phantom anatomical parts were extracted from mouse computed tomography scans and printed using polylactic acid (organs) and a granite/polylactic acid composite (skeleton). The anatomical pieces were encapsulated in silicone rubber to ensure long term stability. The phantom was imaged using x-ray cone-beam computed tomography, proton radiography, ultrasound imaging, and monitoring of a 20 MeV pulsed proton beam using ionoacoustics.Main results.The anatomical parts could be visualized in all the imaging modalities validating the phantom capability to be used for multimodal imaging. Ultrasound images were simulated from the x-ray cone-beam computed tomography and co-registered with ultrasound images obtained before the phantom irradiation and low-resolution ultrasound images of the mouse phantom in the irradiation position, co-registered with ionoacoustic measurements. The latter confirmed the irradiation of a tumor surrogate for which the reconstructed range was found to be in reasonable agreement with the expectation.Significance.This study reports on a realistic small animal phantom which can be used to investigate ionoacoustic range (or dose) verification together with ultrasound, x-ray, and proton imaging. The co-registration between ionoacoustic reconstructions of the impinging proton beam and x-ray imaging is assessed for the first time in a pre-clinical scenario.


Asunto(s)
Terapia de Protones , Animales , Ratones , Fantasmas de Imagen , Impresión Tridimensional , Protones , Reproducibilidad de los Resultados , Elastómeros de Silicona
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA