Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 118
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 34(2): 356-365, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36434798

RESUMEN

INTRODUCTION: Critical isthmuses of atypical atrial flutters (AAFLs) are usually located at slow conduction areas that exhibit fractionated electrograms. We tested a novel software, intended for integration with a commercially available navigation system, that automatically detects fractionated electrograms, to identify the critical isthmus in patients with AAFL ablation. METHODS AND RESULTS: All available patients were analyzed; 27 patients with 33 AAFLs were included. The PentaRay NAV catheter (Biosense Webster) was used for mapping. The novel software was retrospectively applied; fractionated points with duration ≥80 ms and bipolar voltage between 0.05 and 0.5 mV were highlighted on the surface of maps. In 10 randomly chosen AAFLs, an expert electrophysiologist evaluated the positive predictive value of the algorithm to detect true fractionation: 74.4%. We tested the capacity of the software to identify areas of fractionation (defined as clusters of ≥3 adjacent points with fractionation) at the critical isthmus of the AAFLs (defined using conventional mapping criteria). An area of fractionation was identified at the critical isthmus in 30 cases (91%). Globally, 144 areas of fractionation (median number per AAFL 4 [3-6]) were identified. Duration of the fractionation or the surface of the areas was not different between areas at critical isthmuses and the rest. Setting the fractionation score filter of the software in nine provided best performance. CONCLUSIONS: The novel software detected areas of fractionation at the critical isthmus in most AAFLs, which may help identify the critical isthmus in clinical practice.


Asunto(s)
Aleteo Atrial , Ablación por Catéter , Humanos , Estudios Retrospectivos , Ablación por Catéter/métodos , Frecuencia Cardíaca , Valor Predictivo de las Pruebas
2.
Europace ; 25(7)2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37366571

RESUMEN

BACKGROUND AND AIMS: Bayesian analyses can provide additional insights into the results of clinical trials, aiding in the decision-making process. We analysed the Substrate Ablation vs. Antiarrhythmic Drug Therapy for Symptomatic Ventricular Tachycardia (SURVIVE-VT) trial using Bayesian survival models. METHODS AND RESULTS: The SURVIVE-VT trial randomized patients with ischaemic cardiomyopathy and monomorphic ventricular tachycardia (VT) to catheter ablation or antiarrhythmic drugs (AAD) as a first-line strategy. The primary outcome was a composite of cardiovascular death, appropriate implantable cardioverter-defibrillator shocks, unplanned heart failure hospitalizations, or severe treatment-related complications. We used informative, skeptical, and non-informative priors with different probabilities of large effects to compute the posterior distributions using Markov Chain Monte Carlo methods. We calculated the probabilities of hazard ratios (HR) being <1, <0.9, and <0.75, as well as 2-year survival estimates. Of the 144 randomized patients, 71 underwent catheter ablation and 73 received AAD. Regardless of the prior, catheter ablation had a >98% probability of reducing the primary outcome (HR < 1) and a >96% probability of achieving a reduction of >10% (HR < 0.9). The probability of a >25% (HR < 0.75) reduction of treatment-related complications was >90%. Catheter ablation had a high probability (>93%) of reducing incessant/slow undetected VT/electric storm, unplanned hospitalizations for ventricular arrhythmias, and overall cardiovascular admissions > 25%, with absolute differences of 15.2%, 21.2%, and 20.2%, respectively. CONCLUSION: In patients with ischaemic cardiomyopathy and VT, catheter ablation as a first-line therapy resulted in a high probability of reducing several clinical outcomes compared to AAD. Our study highlights the value of Bayesian analysis in clinical trials and its potential for guiding treatment decisions. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT03734562.


Asunto(s)
Cardiomiopatías , Ablación por Catéter , Desfibriladores Implantables , Isquemia Miocárdica , Taquicardia Ventricular , Humanos , Antiarrítmicos/efectos adversos , Teorema de Bayes , Cardiomiopatías/complicaciones , Cardiomiopatías/terapia , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Isquemia Miocárdica/complicaciones , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Resultado del Tratamiento
3.
J Cardiovasc Electrophysiol ; 33(12): 2528-2537, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-36116038

RESUMEN

INTRODUCTION: High-power short-duration (HPSD) has been proposed to shorten procedure times while maintaining efficacy and safety. We evaluated the differences in size and geometry between radiofrequency lesions obtained with this method and conventional ones. METHODS AND RESULTS: Twenty-eight sets of 10 perpendicular radiofrequency applications were performed with two commercially available catheters: a temperature-controlled HPSD catheter (QDot-Micro) and a conventional power-controlled catheter (Thermocool SmartTouch) on porcine left ventricle. Different power settings (35, 40, 50, and 90 W), contact force (CF; 10 and 20 g), ablation index (AI; 400 and 550), and application times were combined to create conventional (35-40 W), HPSD (50 W) and very-high-power short-duration (VHPSD; 90 W) lesions, that were cross-sectioned and measured. About 4-s VHPSD lesions were smaller, shallower, and thinner than HPSD performed with the QDot-Micro catheter in any scenario of CF or AI (61 ± 7.8 mm3 , 6.1 ± 0.3 mm wide, and 2.9 ± 0.1 mm deep with 10 g; 72.2 ± 0.5 mm3 , 6.8 ± 0.3 mm wide, and 2.9 ± 0.2 mm deep with 20 g). Conventional and HPSD lesions performed with the temperature-controlled catheter were generally bigger, deeper, and wider than the ones obtained with the power-controlled catheter, as well as more consistent in size. This was especially true with the lower CF and AI scenario, while differences were less notable with other setting combinations. CONCLUSION: VHPSD lesions performed with QDot-Micro catheter were smaller than any other lesions, which is especially attractive for posterior left atrial wall ablation. On the contrary, conventional-powered and HPSD lesions performed with this catheter were equally sized (or even bigger with lower CF and AI objectives), as well as more consistent in size, which would guarantee transmurality in other locations.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Porcinos , Animales , Venas Pulmonares/cirugía , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Temperatura , Catéteres , Resultado del Tratamiento
4.
Europace ; 20(2): 386-391, 2018 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-29300970

RESUMEN

The purpose of this patient survey was to analyse the knowledge, experiences, and attitudes regarding cardiac implantable electronic devices (CIED) in patients with pacemakers, implantable cardioverter-defibrillators (ICDs), or cardiac resynchronization devices. Of the 1644 patients with CIEDs from seven European countries, 88% were over 50 years of age. Most patients (90%) knew what device they were implanted with and felt sufficiently informed about the indications for therapy. As many as 42% of patients needed additional information on the battery replacement and limitations in physical activity. The self-reported incidence of complications was 9%, and among these, a quarter of the respondents felt insufficiently informed about the possibility of complications and their management. The majority of patients (83%) were followed by face-to-face visits, which was the most commonly preferred follow-up strategy by the patients. Nearly 75% of the patients reported improved quality of life after device implantation, but about 40% had worries about their device. Less than 20% had discussed with their physician or thought about device handling in the end-of-life circumstances or end-stage disease. Notably, almost 20% of the ICD patients did not wish to answer the question regarding what they wanted to be done with their ICD in case of end-stage disease, indicating the challenges in approaching these issues.


Asunto(s)
Desfibriladores Implantables , Conocimientos, Actitudes y Práctica en Salud , Cardiopatías/terapia , Marcapaso Artificial , Pacientes/psicología , Adaptación Psicológica , Anciano , Dispositivos de Terapia de Resincronización Cardíaca , Costo de Enfermedad , Europa (Continente) , Femenino , Encuestas de Atención de la Salud , Cardiopatías/fisiopatología , Cardiopatías/psicología , Humanos , Masculino , Persona de Mediana Edad , Educación del Paciente como Asunto , Prioridad del Paciente , Estudios Prospectivos , Falla de Prótesis , Calidad de Vida
5.
Europace ; 20(11): 1719-1753, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-29579186

RESUMEN

The population of patients with congenital heart disease (CHD) is continuously increasing with more and more patients reaching adulthood. A significant portion of these young adults will suffer from arrhythmias due to the underlying congenital heart defect itself or as a sequela of interventional or surgical treatment. The medical community will encounter an increasing challenge as even most of the individuals with complex congenital heart defects nowadays become young adults. Within the past 20 years, management of patients with arrhythmias has gained remarkable progress including pharmacological treatment, catheter ablation, and device therapy. Catheter ablation in patients with CHD has paralleled the advances of this technology in pediatric and adult patients with structurally normal hearts. Growing experience and introduction of new techniques like the 3D mapping systems into clinical practice have been particularly beneficial for this growing population of patients with abnormal cardiac anatomy and physiology. Finally, device therapies allowing maintanence of chronotropic competence and AV conduction, improving haemodynamics by cardiac resynchronization, and preventing sudden death are increasingly used. For pharmacological therapy, ablation procedures, and device therapy decision making requires a deep understanding of the individual pathological anatomy and physiology as well as detailed knowledge on natural history and long-term prognosis of our patients. Composing expert opinions from cardiology and paediatric cardiology as well as from non-invasive and invasive electrophysiology this position paper was designed to state the art in management of young individuals with congenital heart defects and arrhythmias.


Asunto(s)
Arritmias Cardíacas , Procedimientos Quirúrgicos Cardíacos , Cardiología , Muerte Súbita Cardíaca , Cardiopatías Congénitas , Manejo de Atención al Paciente , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiología , Arritmias Cardíacas/terapia , Terapia de Resincronización Cardíaca/métodos , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/métodos , Cardiología/métodos , Cardiología/tendencias , Ablación por Catéter/métodos , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Técnicas Electrofisiológicas Cardíacas/métodos , Europa (Continente) , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/cirugía , Humanos , Manejo de Atención al Paciente/métodos , Manejo de Atención al Paciente/normas , Adulto Joven
6.
Europace ; 19(2): 303-307, 2017 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-28165525

RESUMEN

The purpose of this survey was to assess the current practice in Europe regarding cryoablation for treatment of different cardiac arrhythmias. The data are based on an electronic questionnaire sent to members of the European Heart Rhythm Association Research Network. Responses were received from 49 centres in 18 countries. The results show that cryoablation for supraventricular tachycardia in European centres is an alternative to radiofrequency ablation, which is in accordance with guidelines. There is reasonable consensus regarding clinical results and complications of cryoablation procedure. Some inter-centre variability with respect to patient selection and ablation strategy in cryoablation of atrial fibrillation was demonstrated, underscoring the need for further research.


Asunto(s)
Arritmias Cardíacas/cirugía , Criocirugía/tendencias , Pautas de la Práctica en Medicina/tendencias , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Ablación por Catéter/tendencias , Europa (Continente) , Adhesión a Directriz/tendencias , Encuestas de Atención de la Salud , Disparidades en Atención de Salud/tendencias , Humanos , Guías de Práctica Clínica como Asunto , Resultado del Tratamiento
7.
Europace ; 19(9): 1579-1584, 2017 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-28934410

RESUMEN

The aim of this European Heart Rhythm Association (EHRA) survey was to evaluate clinical practice regarding cardio-oncologic patients, with special focus on patients with cardiac implantable electronic devices (CIEDs) planned for anticancer radiotherapy (RT), among members of the EHRA electrophysiology research network. Of the 36 responding centres, 89% managed patients who were diagnosed or treated oncologically, and this diagnosis affected 1-5% of cardiovascular patients in majority of centres (57%). The main side effects of anticancer therapy in patients treated by cardiologists were thromboembolic complications and left ventricular dysfunction (both reported as 'frequent' by 43% of the centres). The main agents associated with complications were anthracyclines, RT, and monoclonal antibodies. Echocardiography was the most common method of screening for cardiovascular complications (93%), and 10% of the centres did not routinely screen for treatment-induced cardiotoxicity. Opinions on the safe radiation dose, methods of device shielding, and risk calculation prior to RT in CIED patients differed among centres. Precaution measures in high-risk CIED patients were very heterogeneous among centres. Our survey has shown that the awareness of cardiac consequences of anticancer therapy is high, despite relatively low proportion of patients treated oncologically among all cardiovascular patients. There is a consensus of which screening methods should be used for cardiotoxicity of anticancer treatment, but the apprehension of screening necessity is low. Methods of risk assessment and safety measures in CIED patients undergoing RT are very heterogeneous among the European centres, underscoring the need for standardization of the approach to cardio-oncologic patients.


Asunto(s)
Estimulación Cardíaca Artificial , Cardiología/tendencias , Cardioversión Eléctrica/instrumentación , Cardiopatías/terapia , Neoplasias/radioterapia , Marcapaso Artificial , Oncología por Radiación/tendencias , Antineoplásicos/efectos adversos , Estimulación Cardíaca Artificial/efectos adversos , Estimulación Cardíaca Artificial/mortalidad , Muerte Súbita Cardíaca/etiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores Implantables , Remoción de Dispositivos , Cardioversión Eléctrica/efectos adversos , Cardioversión Eléctrica/mortalidad , Europa (Continente)/epidemiología , Encuestas de Atención de la Salud , Cardiopatías/diagnóstico , Cardiopatías/mortalidad , Cardiopatías/fisiopatología , Humanos , Neoplasias/diagnóstico , Neoplasias/mortalidad , Diseño de Prótesis , Falla de Prótesis , Dosis de Radiación , Exposición a la Radiación/efectos adversos , Radioterapia/efectos adversos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
8.
J Cardiovasc Electrophysiol ; 27(4): 482-7, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26749504

RESUMEN

INTRODUCTION: Ultrasound guidance for vascular cannulation seems safer and more effective than an anatomical landmark approach, though it has not gained widespread support partly due to workflow interference of wired probes. A wireless ultrasound transducer (WUST) may overcome this issue. We report the effectiveness, time consumption, and safety of the first-in-human experience in axillary vein cannulation guided with a novel WUST for the implantation of cardiovascular implantable electric devices (CIEDs). METHODS AND RESULTS: After a one-month training period, we routinely performed WUST-guided puncture to all first implants, prospectively registering data from the first 50 patients. We analyzed the time needed for preparing the WUST and for achieving each vein cannulation, and the rate of unsuccessful or accidental arterial punctures and complications. WUST-guided axillary vein access was successful in 49 out of 50 patients, totaling 86 cannulated veins. Median WUST preparation time was 55 [44-62] seconds and median time needed for each venous cannulation was 56 [36-71] seconds. A total of 84.9% of the veins were cannulated at the first attempt. There were 7 unsuccessful puncture attempts and 1 accidental arterial puncture. No pneumothorax, hemothorax, or nervous injury occurred in the 49 successfully cannulated patients. The unsuccessful one (distal subclavian occlusion) developed a minor local subcutaneous emphysema with no confirmed radiologic pneumothorax, not requiring intervention. During a follow-up of 2.5 ± 1.1 months, a patient developed a pocket infection, with no other significant complications. CONCLUSION: Ultrasound-guided axillary vein cannulation using a wireless transducer for the implantation of CIEDs is a feasible, fast, and safe method.


Asunto(s)
Vena Axilar/ultraestructura , Cateterismo Venoso Central/instrumentación , Marcapaso Artificial , Prótesis e Implantes , Ultrasonografía Intervencional/instrumentación , Tecnología Inalámbrica/instrumentación , Anciano , Cateterismo Venoso Central/métodos , Femenino , Humanos , Masculino , Estudios Prospectivos , Implantación de Prótesis/instrumentación , Implantación de Prótesis/métodos , Transductores , Resultado del Tratamiento , Ultrasonografía Intervencional/métodos
9.
Europace ; 18(1): 146-50, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26842735

RESUMEN

The aim of this European Heart Rhythm Association (EHRA) survey was to collect data on the use of wearable cardioverter-defibrillators (WCDs) among members of the EHRA electrophysiology research network. Of the 50 responding centres, 23 (47%) reported WCD use. Devices were fully reimbursed in 17 (43.6%) of 39 respondents, and partially reimbursed in 3 centres (7.7%). Eleven out of 20 centres (55%) reported acceptable patients' compliance (WCD worn for >90% of time). The most common indications for WCD (8 out of 10 centres; 80%) were covering the period until re-implantation of ICD explanted due to infection, in patients with left ventricular impairment due to myocarditis or recent myocardial infarction and those awaiting heart transplantation. Patient life expectancy of <12 months and poor compliance were the most commonly reported contraindications for WCD (24 of 46 centres, 52.2%). The major problems encountered by physicians managing patients with WCD were costs (8 of 18 centres, 44.4%), non-compliance, and incorrect use of WCD. Four of 17 centres (23.5%) reported inappropriate WCD activations in <5% of patients. The first shock success rate in terminating ventricular arrhythmias was 95-100% in 6 of 15 centres (40%), 85-95% in 4 (26.7%), 75-85% in 2 (13.3%), and <75% in 3 centres (20%). The survey has shown that the use of WCD in Europe is still restricted and depends on reimbursement. Patients' compliance remains low. Heterogeneity of indications for WCD among centres underscores the need for further research and a better definition of indications for WCD in specific patient groups.


Asunto(s)
Muerte Súbita Cardíaca/epidemiología , Muerte Súbita Cardíaca/prevención & control , Desfibriladores/estadística & datos numéricos , Electrocardiografía Ambulatoria/instrumentación , Electrocardiografía Ambulatoria/estadística & datos numéricos , Cooperación del Paciente/estadística & datos numéricos , Anciano , Anciano de 80 o más Años , Electrocardiografía Ambulatoria/mortalidad , Europa (Continente)/epidemiología , Femenino , Encuestas de Atención de la Salud , Humanos , Esperanza de Vida , Masculino , Persona de Mediana Edad , Prevalencia , Tasa de Supervivencia , Revisión de Utilización de Recursos
10.
Europace ; 18(6): 873-80, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26506836

RESUMEN

AIMS: The aim of this study was to determine the acute and long-term outcome of radiofrequency catheter ablation (RFCA) for cavotricuspid isthmus-dependent atrial flutter (CTI-AFL) in adults with and without previous cardiac surgery (PCS), and predictors of these outcomes. Structural alterations of the anatomical substrate of the CTI-AFL are observed in post-operative patients, and these may have an impact on the acute success of the ablation and in the long-term. METHODS AND RESULTS: Clinical records of consecutive adults undergoing RFCA of CTI-AFL were analysed. Two main groups were considered: No PCS and PCS patients, who were further subdivided into acquired heart disease (AHD: ischaemic heart disease and valvular/mixed heart disease) and congenital heart disease [CHD: ostium secundum atrial septal defect (OS-ASD) and complex CHD]. Multivariate analysis identified clinical and procedural factors that predicted acute and long-term outcomes. A total of 666 patients (73% men, age 65 ± 12 years) were included: 307 of them with PCS. Ablation was successful in 647 patients (97%), 96% in the PCS group and 98% in the No PCS group (P = 0.13). Regression analysis showed that surgically corrected complex CHD was related to failure of the procedure [odds ratio 5.6; 95% confidence interval (CI) 1.6-18, P = 0.008]. After a follow-up of 45 ± 15 months, recurrences were observed in 90 patients (14%), more frequently in the PCS group: absolute risk of recurrence 18 vs. 10.5%, relative risk 1.71, 95% CI: 1.2-2.5, P = 0.006. Multivariate analysis indicated that the types of PCS [OS-ASD vs. No PCS: hazard ratio (HR) 2.57; 95% CI: 1.1-6.2, P = 0.03 and complex CHD vs. No PCS: HR 2.75; 95% CI: 1.41-5.48, P = 0.004], female gender (HR 1.55; 95% CI: 1.04-2.4, P = 0.048), and severe LV dysfunction (HR 1.36; 95% CI: 1.06-1.67, P = 0.04) were independent predictors of long-term recurrence. CONCLUSION: Radiofrequency catheter ablation of CTI-AFL after surgical correction of AHD and CHD is associated with high acute success rates. The severity of the structural alterations of the underlying heart disease and consequently the type of surgical correction correlates with higher risk for recurrence.


Asunto(s)
Aleteo Atrial/cirugía , Procedimientos Quirúrgicos Cardíacos , Ablación por Catéter , Cardiopatías/complicaciones , Cardiopatías/cirugía , Adulto , Anciano , Supervivencia sin Enfermedad , Electrocardiografía , Femenino , Estudios de Seguimiento , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Oportunidad Relativa , Complicaciones Posoperatorias/epidemiología , Recurrencia , Estudios Retrospectivos , España , Resultado del Tratamiento , Válvula Tricúspide/fisiopatología , Adulto Joven
11.
Europace ; 18(1): 151-5, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26462697

RESUMEN

The purpose of this European Heart Rhythm Association survey was to assess the attitude, level of education, and knowledge concerning oral anticoagulants (OACs) among patients with atrial fibrillation (AF) taking vitamin K antagonists (VKAs), non-VKA oral anticoagulants (NOACs) or antiplatelets. A total of 1147 patients with AF [mean age 66 ± 13 years, 529 (45%) women] from 8 selected European countries responded to this survey. The overall use of OACs and antiplatelets was 77 and 15.3%, respectively. Of the patients taking OACs, 67% were on VKAs, 33% on NOACs, and 17.9% on a combination of OACs and antiplatelets. Among patients on VKAs, 91% correctly stated the target international normalized ratio (INR) level. The proportion of patients on VKA medication who were aware that monthly INR monitoring was required for this treatment and the proportion of patients on NOAC who knew that renal function monitoring at least annually was mandatory for NOACs was 76 and 21%, respectively. An indirect estimation of compliance indicated that 14.5% of patients temporarily discontinued the treatment, and 26.5% of patients reported having missed at least one dose. The survey shows that there is room for improvement regarding education and adherence of patients taking OACs, particularly regarding monitoring requirements for NOACs.


Asunto(s)
Anticoagulantes/administración & dosificación , Fibrilación Atrial/tratamiento farmacológico , Cumplimiento de la Medicación/estadística & datos numéricos , Educación del Paciente como Asunto/estadística & datos numéricos , Conocimiento de la Medicación por el Paciente/estadística & datos numéricos , Tromboembolia/prevención & control , Administración Oral , Anciano , Fibrilación Atrial/epidemiología , Fibrilación Atrial/psicología , Actitud Frente a la Salud , Autoevaluación Diagnóstica , Europa (Continente)/epidemiología , Femenino , Encuestas de Atención de la Salud , Humanos , Masculino , Inhibidores de Agregación Plaquetaria/administración & dosificación , Tromboembolia/epidemiología , Tromboembolia/psicología , Vitamina K/antagonistas & inhibidores
12.
Europace ; 18(3): 463-7, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26899998

RESUMEN

The purpose of this patient survey was to analyse the knowledge about blood thinning medications relative to gender, age, education, and region of residence in patients with atrial fibrillation (AF). A total of 1147 patients with AF [mean age 66 ± 13 years, 529 (45%) women] from eight European countries responded to this survey. Most patients understood that the indication for anticoagulation therapy was to 'thin the blood', but 8.1% responded that the purpose of the medication was to treat the arrhythmia. Patients with college or university grades reported less frequent deviations from their target INR range compared with those without schooling (2.8% vs. 5.1%, P < 0.05). The awareness of anticoagulation-related risk of bleedings was lowest in patients without schooling (38.5%) and highest in those with college and university education (57.0%), P < 0.05. The same pattern was also observed regarding patient's awareness of non-vitamin K antagonist oral anticoagulants (NOACs): 56.5% of the patients with university education and only 20.5% of those without schooling (P < 0.05) knew about NOACs, indicating that information about new anticoagulation therapies remains well below the target. Bleeding events were statistically less frequent in patients on NOACs compared with vitamin K antagonists. The education level and patients' knowledge have a direct influence on the global management of the anticoagulation.


Asunto(s)
Anticoagulantes/administración & dosificación , Fibrilación Atrial/tratamiento farmacológico , Conocimientos, Actitudes y Práctica en Salud , Educación del Paciente como Asunto , Pacientes/psicología , Accidente Cerebrovascular/prevención & control , Administración Oral , Anciano , Anticoagulantes/efectos adversos , Fibrilación Atrial/sangre , Fibrilación Atrial/complicaciones , Coagulación Sanguínea/efectos de los fármacos , Monitoreo de Drogas/métodos , Escolaridad , Europa (Continente) , Femenino , Encuestas de Atención de la Salud , Hemorragia/inducido químicamente , Humanos , Relación Normalizada Internacional , Masculino , Cumplimiento de la Medicación , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Medición de Riesgo , Factores de Riesgo , Accidente Cerebrovascular/etiología , Resultado del Tratamiento , Vitamina K/antagonistas & inhibidores
13.
Pacing Clin Electrophysiol ; 39(7): 633-41, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-27019211

RESUMEN

BACKGROUND: Different types of ventricular arrhythmias (monomorphic ventricular tachycardia [VT], polymorphic VT, or ventricular fibrillation) can be detected by implantable cardiac defibrillators (ICDs) in fast VT zone. The efficacy of antitachycardia pacing (ATP) depends on the type of the treated arrhythmia. We hypothesized that an automatic algorithm based on morphological affinity of ICD far-field electrograms during tachycardia can predict ATP success and the need of shock. METHODS: The algorithm was evaluated on ventricular arrhythmias recorded in CareLink ICD remote monitoring system (Medtronic Inc., Minneapolis, MN, USA). Patients were selected if first ATP programmed was a burst of eight pulses at 88% coupling interval and if a far-field electrogram was available. The algorithm calculated a stability coefficient (SC) for all their stored ATP-treated fast ventricular arrhythmia (VA) episodes (LC 200-300 ms), analyzing the morphology homogeneity of the last eight recorded far-field electrograms before ventricular arrhythmias detection. RESULTS: Inclusion criteria were fulfilled by 717 patients from 29 centers. Three hundred and twenty fast VA were recorded in 103 patients. A higher SC was observed in episodes terminated with the first-ATP (0.78 [0.72-0.84] vs 0.74 [0.60-0.84]; P = 0.006). These differences were especially marked among the 62 episodes of very fast VA (CL ≤250 ms) (0.77 [0.74-0.85] vs 0.64 [0.51-0.8]; P = 0.006). In the multivariate analysis, a SC > 70% was independently associated with a higher likelihood of first-ATP success (odds ratio [OR] = 2.5; [95% confidence interval (CI) = 1.4-4.5], P = 0.001) and a lower need of shock (OR = 0.37; [95% CI = 0.2-0.7], P = 0.002). CONCLUSION: This automatic algorithm (stability coefficient) shows that ATP therapy response can be predicted in fast ventricular arrhythmias through morphology evaluation.


Asunto(s)
Algoritmos , Técnicas Electrofisiológicas Cardíacas/métodos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/prevención & control , Fibrilación Ventricular/diagnóstico , Fibrilación Ventricular/prevención & control , Estimulación Cardíaca Artificial , Desfibriladores Implantables , Diagnóstico por Computador/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud/métodos , Pronóstico , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , España , Terapia Asistida por Computador/métodos , Resultado del Tratamiento
14.
Europace ; 17(9): 1449-53, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26443791

RESUMEN

The management of arrhythmias detected by implantable cardiac devices can be challenging. There are no formal international guidelines to inform decision-making. The purpose of this European Heart Rhythm Association (EHRA) survey was to assess the management of various clinical scenarios among members of the EHRA electrophysiology research network. There were 49 responses to the questionnaire. The survey responses were mainly (81%) from medium-high volume device implanting centres, performing more than 200 total device implants per year. Clinical scenarios were described focusing on four key areas: the implantation of pacemakers for bradyarrhythmia detected on an implantable loop recorder (ILR), the management of patients with ventricular arrhythmia detected by an ILR or pacemaker, the management of atrial fibrillation in patients with pacemakers and cardiac resynchronization therapy devices and the management of ventricular tachycardia in patients with implantable cardioverter-defibrillators.


Asunto(s)
Fibrilación Atrial/terapia , Bradicardia/terapia , Dispositivos de Terapia de Resincronización Cardíaca , Desfibriladores Implantables , Pautas de la Práctica en Medicina/estadística & datos numéricos , Taquicardia Ventricular/terapia , Ablación por Catéter/métodos , Europa (Continente) , Humanos , Sociedades Médicas , Encuestas y Cuestionarios
15.
Europace ; 17(10): 1596-600, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26498718

RESUMEN

The aim of this survey was to provide insight into current practice regarding ablation of persistent atrial fibrillation (AF) among members of the European Heart Rhythm Association electrophysiology research network. Thirty centres responded to the survey. The main ablation technique for first-time ablation was stand-alone pulmonary vein isolation (PVI): in 67% of the centres for persistent but not long-standing AF and in 37% of the centres for long-standing persistent AF as well. Other applied techniques were ablation of fractionated electrograms, placement of linear lesions, stepwise approach until AF termination, and substrate mapping and isolation of low-voltage areas. However, the percentage of centres applying these techniques during first ablation did not exceed 25% for any technique. When stand-alone PVI was performed in patients with persistent but not long-standing AF, the majority (80%) of the centres used an irrigated radiofrequency ablation catheter whereas 20% of the respondents used the cryoballoon. Similar results were reported for ablation of long-standing persistent AF (radiofrequency 90%, cryoballoon 10%). Neither rotor mapping nor one-shot ablation tools were used as the main first-time ablation methods. Systematic search for non-pulmonary vein triggers was performed only in 10% of the centres. Most common 1-year success rate off antiarrhythmic drugs was 50-60%. Only 27% of the centres knew their 5-year results. In conclusion, patients with persistent AF represent a significant proportion of AF patients undergoing ablation. There is a shift towards stand-alone PVI being the primary choice in many centres for first-time ablation in these patients. The wide variation in the use of additional techniques and in the choice of endpoints reflects the uncertainties and lack of guidance regarding the most optimal approach. Procedural success rates are modest and long-term outcomes are unknown in most centres.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/estadística & datos numéricos , Ablación por Catéter/normas , Venas Pulmonares/cirugía , Europa (Continente) , Humanos , Sociedades Médicas , Encuestas y Cuestionarios , Resultado del Tratamiento
16.
Europace ; 17(7): 1149-52, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26116687

RESUMEN

Despite the advent of non-fluoroscopic technologies, fluoroscopy remains the cornerstone of imaging in most interventional electrophysiological procedures, from diagnostic studies to ablation interventions and device implantation. The purpose of the European Heart Rhythm Association survey was to provide an insight into regulatory policies and physicians' clinical practice when using fluoroscopy during ablation procedures and device implantation. The survey has shown that only 50% of the participating centres worked with low frame rates (3-6 frames per second) and that the left anterior oblique projection, with higher radiation exposure for the physician, is used for nearly every ablation target. Although three-dimensional imaging systems may reduce the radiation exposure, most centres never used these systems for standard ablation procedures and a trend is that non-fluoroscopy technologies are even less frequently used than in 2012, when the use of robotic systems was still rare. Even less costly equipment such as lead gloves, lead glass cabins, or radiation absorbing pads are still not routinely used.


Asunto(s)
Desfibriladores Implantables/estadística & datos numéricos , Técnicas Electrofisiológicas Cardíacas/estadística & datos numéricos , Fluoroscopía/estadística & datos numéricos , Implantación de Prótesis/estadística & datos numéricos , Protección Radiológica/estadística & datos numéricos , Radiografía Intervencional/estadística & datos numéricos , Europa (Continente)/epidemiología , Encuestas de Atención de la Salud , Dosis de Radiación
17.
Europace ; 17(1): 148-51, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-25552672

RESUMEN

The purpose of this European Heart Rhythm Association (EHRA) EP wire survey was to evaluate the implementation of the current guidelines for cardiac pacing and cardiac resynchronization therapy (CRT) in Europe. A total of 48 centres replied to the survey, 34 of them (71%) were university hospitals. All responding centres implement CRT in patients with classical indications, i.e. sinus rhythm, New York Heart Association (NYHA) functional class II, III, or ambulatory IV, left ventricular ejection fraction (LVEF) 35%, and left bundle-branch block (LBBB) with QRS duration >150 ms, while 31 centres (67%) would implant a CRT device in patients with the same characteristics but with a non-LBBB pattern. Forty-one centres (89%) would also implant CRT in patients with sinus rhythm, NYHA Class II, III, or ambulatory IV, LVEF <35%, and LBBB with QRS duration between 120 and 150 ms, while only eight centres (17%) would implant the device in patients with the same characteristics but with a non-LBBB pattern. In patients with LVEF <35% and QRS duration below 120 ms, the majority of the centres (80%) would implant a single- or dual-chamber implantable cardioverter-defibrillator, but in nine cases (20%) no device was considered to be indicated. The results of this survey showed a good adherence to some of the current recommendations. Still some reluctance exists when offering the device therapy to patients with QRS duration in the lower range.


Asunto(s)
Estimulación Cardíaca Artificial/estadística & datos numéricos , Estimulación Cardíaca Artificial/normas , Terapia de Resincronización Cardíaca/estadística & datos numéricos , Terapia de Resincronización Cardíaca/normas , Adhesión a Directriz/estadística & datos numéricos , Insuficiencia Cardíaca/prevención & control , Cardiología/normas , Europa (Continente)/epidemiología , Encuestas de Atención de la Salud , Insuficiencia Cardíaca/epidemiología , Humanos , Pautas de la Práctica en Medicina/normas , Pautas de la Práctica en Medicina/estadística & datos numéricos , Prevalencia
18.
Europace ; 17(11): 1727-32, 2015 11.
Artículo en Inglés | MEDLINE | ID: mdl-26462700

RESUMEN

The European Snapshot Survey on Procedural Routines in Atrial Fibrillation Ablation (ESS-PRAFA) is a prospective, multicentre snapshot survey collecting patient-based data on current clinical practices during atrial fibrillation (AF) ablation. The participating centres were asked to prospectively enrol consecutive patients during a 6-week period (from September to October 2014). A web-based case report form was employed to collect information of patients and data of procedures. A total of 455 eligible consecutive patients from 13 countries were enrolled (mean age 59 ± 10.8 years, 28.8% women). Distinct strategies and endpoints were collected for AF ablation procedures. Pulmonary vein isolation (PVI) was performed in 96.7% and served as the endpoint in 91.3% of procedures. A total of 52 (11.5%) patients underwent ablation as first-line therapy. The cryoballoon technique was employed in 31.4% of procedures. Procedure, ablation, and fluoroscopy times differed among various types of AF ablation. Divergences in patient selection and complications were observed among low-, medium-, and high-volume centres. Adverse events were observed in 4.6% of AF ablation procedures. In conclusion, PVI was still the main strategy for AF ablation. Procedure-related complications seemed not to have declined. The centre volume played an important role in patient selection, strategy choice, and had impact on the rate of periprocedural complication.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Criocirugía , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Criocirugía/efectos adversos , Europa (Continente) , Femenino , Fluoroscopía , Encuestas de Atención de la Salud , Hospitales de Alto Volumen , Hospitales de Bajo Volumen , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Complicaciones Posoperatorias/etiología , Pautas de la Práctica en Medicina , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Encuestas y Cuestionarios , Factores de Tiempo , Resultado del Tratamiento
19.
Europace ; 17(11): 1733-8, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26589904

RESUMEN

Clinical practice should follow guidelines and recommendations mainly based on the results of controlled trials, which are often conducted in selected populations and special conditions, whereas clinical practice may be influenced by factors different from controlled scientific studies. Hence, the real-world setting is better assessed by the observational registries enrolling patients for longer periods of time. However, this may be difficult, expensive, and time-consuming. In 2009, the Scientific Initiatives Committee of the European Heart Rhythm Association (EHRA) has instigated a series of surveys covering the controversial issues in clinical electrophysiology (EP). With this in mind, an EHRA EP research network has been created, which included EP centres in Europe among which the surveys on 'hot topic' were circulated. This review summarizes the overall experience conducting EP wires over the past 6 years, categorizing and assessing the topics regarding clinical EP, and evaluating the acceptance and feedback from the responding centres, in order to improve participation in the surveys and better address the research needs and aspirations of the European EP community.


Asunto(s)
Arritmias Cardíacas , Investigación Biomédica/métodos , Encuestas de Atención de la Salud , Comunicación Interdisciplinaria , Cooperación Internacional , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidad , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/terapia , Conducta Cooperativa , Europa (Continente) , Medicina Basada en la Evidencia , Humanos , Pautas de la Práctica en Medicina , Resultado del Tratamiento
20.
Pacing Clin Electrophysiol ; 38(9): 1058-65, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26010612

RESUMEN

BACKGROUND: Ultrasound (US) guidance increases safety and efficacy in vascular cannulation and is considered the standard of care. However, barriers including workflow interference and the need to be assisted by a second operator limit its adoption in clinical routine. The use of wireless US (WUS) may overcome these barriers. The aim of this study was to assess the impact of a novel WUS probe during its initial implantation in an electrophysiology (EP) laboratory. METHODS: Thirty-six patients requiring femoral venous cannulation for EP procedures were included in this single center, prospective, observational study, comparing WUS guidance with the anatomical landmark approach. The primary endpoint was time to successful cannulation. Secondary endpoints included rate of unsuccessful punctures, accidental arterial punctures, and workflow interference. RESULTS: Compared with anatomical landmark approach, WUS guidance significantly reduced mean time to successful cannulation (87.3 ± 94.3 vs 238.1 ± 294.7 seconds, P < 0.01). Workflow interference was predominantly nonexistent or mild and decreased after the first three weeks of use. In addition, WUS guidance improved safety and efficacy, reducing the rate of accidental arterial punctures (0.02 ± 0.1 vs 0.25 ± 0.5 arterial punctures per cannulation, P < 0.05) and unsuccessful attempts (0.26 ± 0.8 vs 1.75 ± 2.1 attempts per cannulation, P < 0.01). CONCLUSIONS: WUS guidance resulted in faster, safer, and more effective femoral venous cannulation than the anatomical landmark approach without adding significant workflow interference. The application of wireless technology in this setting contributed to overcoming some of the barriers preventing a more widespread clinical use of US guidance.


Asunto(s)
Cateterismo/instrumentación , Técnicas Electrofisiológicas Cardíacas/instrumentación , Vena Femoral/diagnóstico por imagen , Ultrasonografía Intervencional/instrumentación , Tecnología Inalámbrica/instrumentación , Flujo de Trabajo , Anciano , Cateterismo/efectos adversos , Cateterismo/métodos , Técnicas Electrofisiológicas Cardíacas/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Punciones/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Transductores/efectos adversos , Ultrasonografía Intervencional/efectos adversos , Lesiones del Sistema Vascular/etiología , Lesiones del Sistema Vascular/prevención & control
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA