Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
N Engl J Med ; 382(8): 697-705, 2020 02 20.
Artículo en Inglés | MEDLINE | ID: mdl-31860793

RESUMEN

BACKGROUND: The causative agents for the current national outbreak of electronic-cigarette, or vaping, product use-associated lung injury (EVALI) have not been established. Detection of toxicants in bronchoalveolar-lavage (BAL) fluid from patients with EVALI can provide direct information on exposure within the lung. METHODS: BAL fluids were collected from 51 patients with EVALI in 16 states and from 99 healthy participants who were part of an ongoing study of smoking involving nonsmokers, exclusive users of e-cigarettes or vaping products, and exclusive cigarette smokers that was initiated in 2015. Using the BAL fluid, we performed isotope dilution mass spectrometry to measure several priority toxicants: vitamin E acetate, plant oils, medium-chain triglyceride oil, coconut oil, petroleum distillates, and diluent terpenes. RESULTS: State and local health departments assigned EVALI case status as confirmed for 25 patients and as probable for 26 patients. Vitamin E acetate was identified in BAL fluid obtained from 48 of 51 case patients (94%) in 16 states but not in such fluid obtained from the healthy comparator group. No other priority toxicants were found in BAL fluid from the case patients or the comparator group, except for coconut oil and limonene, which were found in 1 patient each. Among the case patients for whom laboratory or epidemiologic data were available, 47 of 50 (94%) had detectable tetrahydrocannabinol (THC) or its metabolites in BAL fluid or had reported vaping THC products in the 90 days before the onset of illness. Nicotine or its metabolites were detected in 30 of 47 of the case patients (64%). CONCLUSIONS: Vitamin E acetate was associated with EVALI in a convenience sample of 51 patients in 16 states across the United States. (Funded by the National Cancer Institute and others.).


Asunto(s)
Lesión Pulmonar Aguda/patología , Líquido del Lavado Bronquioalveolar/química , Sistemas Electrónicos de Liberación de Nicotina , Vapeo/efectos adversos , Vitamina E/análisis , Lesión Pulmonar Aguda/etiología , Adolescente , Adulto , Anciano , Fumar Cigarrillos , Aceite de Coco/análisis , Femenino , Humanos , Limoneno/análisis , Masculino , Persona de Mediana Edad , Estados Unidos , Adulto Joven
2.
Molecules ; 21(1): E23, 2015 Dec 24.
Artículo en Inglés | MEDLINE | ID: mdl-26712725

RESUMEN

Asymmetric monomethine cyanines have been extensively used as probes for nucleic acids among other biological systems. Herein we report the synthesis of seven monomethine cyanine dyes that have been successfully prepared with various heterocyclic moieties such as quinoline, benzoxazole, benzothiazole, dimethyl indole, and benz[e]indole adjoining benz[c,d]indol-1-ium, which was found to directly influence their optical and energy profiles. In this study the optical properties vs. structural changes were investigated using nuclear magnetic resonance and computational approaches. The twisted conformation unique to monomethine cyanines was exploited in DNA binding studies where the newly designed sensor displayed an increase in fluorescence when bound in the DNA grooves compared to the unbound form.


Asunto(s)
Carbocianinas/síntesis química , Colorantes Fluorescentes/síntesis química , Ácidos Nucleicos/química , Carbocianinas/química , Biología Computacional/métodos , Colorantes Fluorescentes/química , Espectroscopía de Resonancia Magnética , Estructura Molecular , Fenómenos Ópticos
3.
Front Chem ; 9: 695940, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34476231

RESUMEN

In August 2019, the Centers for Disease Control and Prevention (CDC) received the first reports of lung injuries that were eventually termed e-cigarette, or vaping, product use-associated lung injury (EVALI). As part of the investigation, CDC laboratories rapidly developed assays for analyzing substances in bronchoalveolar lavage (BAL) fluid collected from EVALI case patients. This report describes the development and validation of a high-throughput isotope dilution UHPLC-MS/MS method for measuring a major oxidative stress biomarker, 8-iso-prostaglandin F2α (8-isoprostane), in BAL fluid samples. The method showed good sensitivity, 17.6 pg/ml LOD, and requires only 50 µl of sample volume. The method had high throughput with an analytical run time of 11 min. The within-day and between-day coefficient of variation (CV) were below 2%. Accuracy, calculated from spiked recovery, at three spiking levels, ranged from 95.5-101.8%. This novel UHPLC-MS/MS method characterizes oxidative stress in lung epithelial tissue and thus helps to elucidate potential pathologic processes.

4.
ACS Omega ; 5(19): 10919-10926, 2020 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-32455212

RESUMEN

Oxidative stress (OS) plays a major role in the pathogenesis of various diseases in humans. OS is a result of an imbalance between reactive oxygen species (ROS) and the biologically available antioxidants that prevent or repair damage that ROS inflict on the host cells. ROS are naturally generated during normal mitochondrial respiration and by oxidative burst during the immune response. Many factors may influence OS, including genetics, diet, exercise, and exposure to environmental toxicants (e.g., tobacco smoke). A nonenzymatic peroxidation product of arachidonic acid (AA), 8-iso-PGF2α (8-isoprostane), is a validated biomarker of OS that is present in urine as both glucuronide conjugate and free acid. Previous studies report that the conjugated forms of 8-isoprostane can vary between 30 and 80% of the total 8-isoprostane levels. By hydrolyzing the conjugated forms, it is possible to obtain a total (free + conjugated) measurement of 8-isoprostane in urine samples. Here, we describe a robust, automated, and high-throughput method for measuring total urinary 8-isoprostane using a polymeric weak anion-exchange solid-phase extraction (SPE) and isotope-dilution ultrahigh performance liquid chromatography electrospray ionization-tandem mass spectrometry (UHPLC-MS/MS). This method, using a 96-well plate platform, showed good sensitivity (8.8 pg/mL LOD) and used only 400 µL of the sample volume with a cycle time of 11 min. The inter- and intraday precision, calculated from 20 repeated measurements of two quality control pools, varied from 4 to 10%. Accuracy, calculated from the recovery percentage at three spiking levels, ranged from 92.7 to 106.7%. We modified this method to allow for the exclusive measurement of free 8-isoprostane by removing the hydrolysis step. We measured both free and total 8-isoprostane in urine collected from 30 cigarette smokers (free: 460 ± 78.8 pg/mL; total: 704 ± 108 pg/mL) and 30 nonusers of tobacco products (free: 110 ± 24.2 pg/mL; total: 161 ± 38.7 pg/mL). This method is robust, accurate, and easily adaptable for large population studies.

5.
Int J Hyg Environ Health ; 222(5): 816-823, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-31085112

RESUMEN

BACKGROUND: Electronic cigarette (e-cigarette) conventions regularly bring together thousands of users around the world. In these environments, secondhand exposures to high concentrations of e-cigarette emissions are prevalent. Some biomarkers for tobacco smoke exposure may be used to characterize secondhand e-cigarette exposures in such an environment. METHODS: Participants who did not use any tobacco product attended four separate e-cigarette events for approximately six hours. Urine and saliva samples were collected from participants prior to the event, immediately after the event, 4-h after the event, and the next morning (first void). Urine samples from 34 participants were analyzed for cotinine, trans-3'-hydroxycotinine, S-(3-hydroxypropyl)-N-acetylcysteine (3-HPMA), S-carboxyethyl-N-acetylcysteine (CEMA), select tobacco-specific nitrosamines (TSNAs), and 8-isoprostane. Saliva samples were analyzed for cotinine and trans-3'-hydroxycotinine. RESULTS: Data from 28 of 34 participants were used in the data analysis. Creatinine-adjusted urinary cotinine concentrations increased up to 13-fold and peaked 4-h after completed exposure (range of adjusted geometric means [AGMs] = 0.352-2.31 µg/g creatinine). Salivary cotinine concentrations were also the highest 4-h after completed exposure (range of AGMs = 0.0373-0.167 ng/mL). Salivary cotinine and creatinine-corrected concentrations of urinary cotinine, trans-3'-hydroxycotinine, CEMA, and 3-HPMA varied significantly across sampling times. Urinary and salivary cotinine, urinary trans-3'-hydroxycotinine, and urinary 3-HPMA concentrations also varied significantly across events. CONCLUSION: Secondhand e-cigarette exposures lasting six hours resulted in significant changes in exposure biomarker concentrations of both nicotine and acrolein but did not change exposure to tobacco-specific nitrosamines. Additional research is needed to understand the relationship between biomarker concentrations and environmental concentrations of toxicants in e-cigarette emissions.


Asunto(s)
Sistemas Electrónicos de Liberación de Nicotina , Contaminación por Humo de Tabaco/análisis , Vapeo/efectos adversos , Acetilcisteína/análogos & derivados , Acetilcisteína/metabolismo , Acetilcisteína/orina , Acroleína/análisis , Adulto , Biomarcadores/metabolismo , Biomarcadores/orina , Cotinina/análogos & derivados , Cotinina/metabolismo , Cotinina/orina , Monitoreo del Ambiente , Femenino , Humanos , Masculino
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA