Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Neuroimage ; 233: 117955, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33716155

RESUMEN

Cerebrovascular reactivity (CVR) reflects the capacity of the brain to meet changing physiological demands and can predict the risk of cerebrovascular diseases. CVR can be obtained by measuring the change in cerebral blood flow (CBF) during a brain stress test where CBF is altered by a vasodilator such as acetazolamide. Although the gold standard to quantify CBF is PET imaging, the procedure is invasive and inaccessible to most patients. Arterial spin labeling (ASL) is a non-invasive and quantitative MRI method to measure CBF, and a consensus guideline has been published for the clinical application of ASL. Despite single post labeling delay (PLD) pseudo-continuous ASL (PCASL) being the recommended ASL technique for CBF quantification, it is sensitive to variations to the arterial transit time (ATT) and labeling efficiency induced by the vasodilator in CVR studies. Multi-PLD ASL controls for the changes in ATT, and velocity selective ASL is in theory insensitive to both ATT and labeling efficiency. Here we investigate CVR using simultaneous 15O-water PET and ASL MRI data from 19 healthy subjects. CVR and CBF measured by the ASL techniques were compared using PET as the reference technique. The impacts of blood T1 and labeling efficiency on ASL were assessed using individual measurements of hematocrit and flow velocity data of the carotid and vertebral arteries measured using phase-contrast MRI. We found that multi-PLD PCASL is the ASL technique most consistent with PET for CVR quantification (group mean CVR of the whole brain = 42±19% and 40±18% respectively). Single-PLD ASL underestimated the CVR of the whole brain significantly by 15±10% compared with PET (p<0.01, paired t-test). Changes in ATT pre- and post-acetazolamide was the principal factor affecting ASL-based CVR quantification. Variations in labeling efficiency and blood T1 had negligible effects.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Encéfalo/metabolismo , Trastornos Cerebrovasculares/metabolismo , Imagen por Resonancia Magnética/normas , Tomografía de Emisión de Positrones/normas , Marcadores de Spin , Adulto , Anciano , Encéfalo/diagnóstico por imagen , Circulación Cerebrovascular/fisiología , Trastornos Cerebrovasculares/diagnóstico por imagen , Femenino , Hematócrito/métodos , Hematócrito/normas , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Radioisótopos de Oxígeno/metabolismo , Tomografía de Emisión de Positrones/métodos , Factores de Tiempo , Agua/metabolismo
2.
Eur J Nucl Med Mol Imaging ; 48(8): 2416-2425, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33416955

RESUMEN

PURPOSE: While sampled or short-frame realizations have shown the potential power of deep learning to reduce radiation dose for PET images, evidence in true injected ultra-low-dose cases is lacking. Therefore, we evaluated deep learning enhancement using a significantly reduced injected radiotracer protocol for amyloid PET/MRI. METHODS: Eighteen participants underwent two separate 18F-florbetaben PET/MRI studies in which an ultra-low-dose (6.64 ± 3.57 MBq, 2.2 ± 1.3% of standard) or a standard-dose (300 ± 14 MBq) was injected. The PET counts from the standard-dose list-mode data were also undersampled to approximate an ultra-low-dose session. A pre-trained convolutional neural network was fine-tuned using MR images and either the injected or sampled ultra-low-dose PET as inputs. Image quality of the enhanced images was evaluated using three metrics (peak signal-to-noise ratio, structural similarity, and root mean square error), as well as the coefficient of variation (CV) for regional standard uptake value ratios (SUVRs). Mean cerebral uptake was correlated across image types to assess the validity of the sampled realizations. To judge clinical performance, four trained readers scored image quality on a five-point scale (using 15% non-inferiority limits for proportion of studies rated 3 or better) and classified cases into amyloid-positive and negative studies. RESULTS: The deep learning-enhanced PET images showed marked improvement on all quality metrics compared with the low-dose images as well as having generally similar regional CVs as the standard-dose. All enhanced images were non-inferior to their standard-dose counterparts. Accuracy for amyloid status was high (97.2% and 91.7% for images enhanced from injected and sampled ultra-low-dose data, respectively) which was similar to intra-reader reproducibility of standard-dose images (98.6%). CONCLUSION: Deep learning methods can synthesize diagnostic-quality PET images from ultra-low injected dose simultaneous PET/MRI data, demonstrating the general validity of sampled realizations and the potential to reduce dose significantly for amyloid imaging.


Asunto(s)
Aprendizaje Profundo , Humanos , Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Tomografía de Emisión de Positrones , Reproducibilidad de los Resultados , Tomografía Computarizada por Rayos X
3.
Eur J Nucl Med Mol Imaging ; 47(9): 2123-2130, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-31938892

RESUMEN

PURPOSE: To assess the safety, biodistribution, and radiation dosimetry of the novel positron emission tomography (PET) radiopharmaceutical 1-((2-fluoro-6-[[18F]]fluorophenyl)sulfonyl)-4-((4-methoxyphenyl)sulfonyl)piperazine ([18F]DASA-23) in healthy volunteers. METHODS: We recruited 5 healthy volunteers who provided a written informed consent. Volunteers were injected with 295.0 ± 8.2 MBq of [18F]DASA-23 intravenously. Immediately following injection, a dynamic scan of the brain was acquired for 15 min. This was followed by serial whole-body PET/MRI scans acquired up to 3 h post-injection. Blood samples were collected at regular intervals, and vital signs monitored pre- and post-radiotracer administration. Regions of interest were drawn around multiple organs, time-activity curves were calculated, and organ uptake and dosimetry were estimated with OLINDA/EXM (version 1.1) software. RESULTS: All subjects tolerated the PET/MRI examination, without adverse reactions to [18F]DASA-23. [18F]DASA-23 passively crossed the blood-brain barrier, followed by rapid clearance from the brain. High accumulation of [18F]DASA-23 was noted in organs such as the gallbladder, liver, small intestine, and urinary bladder, suggesting hepatobiliary and urinary clearance. The effective dose of [18F]DASA-23 was 23.5 ± 5.8 µSv/MBq. CONCLUSION: We successfully completed a pilot first-in-human study of [18F]DASA-23. Our results indicate that [18F]DASA-23 can be used safely in humans to evaluate pyruvate kinase M2 levels. Ongoing studies are evaluating the ability of [18F]DASA-23 to visualize intracranial malignancies, NCT03539731. TRIAL REGISTRATION: ClinicalTrials.gov , NCT03539731 (registered 28 May 2018).


Asunto(s)
Tomografía de Emisión de Positrones , Piruvato Quinasa , Compuestos de Diazonio , Humanos , Piruvato Quinasa/metabolismo , Radiometría , Ácidos Sulfanílicos , Distribución Tisular
4.
J Magn Reson Imaging ; 51(1): 183-194, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31044459

RESUMEN

BACKGROUND: H215 O-positron emission tomography (PET) is considered the reference standard for absolute cerebral blood flow (CBF). However, this technique requires an arterial input function measured through continuous sampling of arterial blood, which is invasive and has limitations with tracer delay and dispersion. PURPOSE: To demonstrate a new noninvasive method to quantify absolute CBF with a PET/MRI hybrid scanner. This blood-free approach, called PC-PET, takes the spatial CBF distribution from a static H215 O-PET scan, and scales it to the whole-brain average CBF value measured by simultaneous phase-contrast MRI. STUDY TYPE: Observational. SUBJECTS: Twelve healthy controls (HC) and 13 patients with Moyamoya disease (MM) as a model of chronic ischemic disease. FIELD STRENGTH/SEQUENCES: 3T/2D cardiac-gated phase-contrast MRI and H215 O-PET. ASSESSMENT: PC-PET CBF values from whole brain (WB), gray matter (GM), and white matter (WM) in HCs were compared with literature values since 2000. CBF and cerebrovascular reactivity (CVR), which is defined as the percent CBF change between baseline and post-acetazolamide (vasodilator) scans, were measured by PC-PET in MM patients and HCs within cortical regions corresponding to major vascular territories. Statistical Tests: Linear, mixed effects models were created to compare CBF and CVR, respectively, between patients and controls, and between different degrees of stenosis. RESULTS: The mean CBF values in WB, GM, and WM in HC were 42 ± 7 ml/100 g/min, 50 ± 7 ml/100 g/min, and 23 ± 3 ml/100 g/min, respectively, which agree well with literature values. Compared with normal regions (57 ± 23%), patients showed significantly decreased CVR in areas with mild/moderate stenosis (47 ± 17%, P = 0.011) and in severe/occluded areas (40 ± 16%, P = 0.016). Data Conclusion: PC-PET identifies differences in cerebrovascular reactivity between healthy controls and cerebrovascular patients. PC-PET is suitable for CBF measurement when arterial blood sampling is not accessible, and warrants comparison to fully quantitative H215 O-PET in future studies. LEVEL OF EVIDENCE: 3 Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2019. J. Magn. Reson. Imaging 2020;51:183-194.


Asunto(s)
Circulación Cerebrovascular/fisiología , Imagen por Resonancia Magnética/métodos , Enfermedad de Moyamoya/diagnóstico por imagen , Enfermedad de Moyamoya/fisiopatología , Imagen Multimodal/métodos , Tomografía de Emisión de Positrones/métodos , Adulto , Encéfalo/diagnóstico por imagen , Encéfalo/fisiopatología , Femenino , Humanos , Masculino , Radioisótopos de Oxígeno
5.
Clin J Sport Med ; 30(1): e11-e14, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-30908328

RESUMEN

A 61-year-old man presented with chronic dorsal foot pain of 9 years that worsened with ambulation. Conventional diagnostic imaging and medical workup were unrevealing, and ankle arthrodesis had been recommended by an orthopedic surgeon for pain relief. Instead, the patient participated in a clinical imaging trial designed for identifying pain generators using whole-body fluorodeoxyglucose (18F-FDG) positron emission tomography/magnetic resonance imaging (PET/MRI). The scan revealed not only high 18F-FDG uptake at the site of pain, but also a hematoma and an inflamed, fibrotic, ruptured plantaris muscle. The fibrotic plantaris likely altered biomechanics with walking, explaining why symptoms worsened with activity. A simple tenotomy of the plantaris tendon was performed to decouple ankle movement from the plantaris injury, resulting in pain relief. This case illustrates the potential of whole-body 18F-FDG PET/MRI to better localize pain generators.


Asunto(s)
Dolor Crónico/etiología , Pie/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Tomografía de Emisión de Positrones/métodos , Tendinopatía/diagnóstico por imagen , Tendinopatía/cirugía , Tenotomía , Imagen de Cuerpo Entero , Fluorodesoxiglucosa F18 , Humanos , Masculino , Persona de Mediana Edad , Músculo Esquelético/diagnóstico por imagen
6.
Stroke ; 50(2): 373-380, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30636572

RESUMEN

Background and Purpose- Noninvasive imaging of brain perfusion has the potential to elucidate pathophysiological mechanisms underlying Moyamoya disease and enable clinical imaging of cerebral blood flow (CBF) to select revascularization therapies for patients. We used hybrid positron emission tomography (PET)/magnetic resonance imaging (MRI) technology to characterize the distribution of hypoperfusion in Moyamoya disease and its relationship to vessel stenosis severity, through comparisons with a normative perfusion database of healthy controls. Methods- To image CBF, we acquired [15O]-water PET as a reference and simultaneously acquired arterial spin labeling (ASL) MRI scans in 20 Moyamoya patients and 15 age-matched, healthy controls on a PET/MRI scanner. The ASL MRI scans included a standard single-delay ASL scan with postlabel delay of 2.0 s and a multidelay scan with 5 postlabel delays (0.7-3.0s) to estimate and account for arterial transit time in CBF quantification. The percent volume of hypoperfusion in patients (determined as the fifth percentile of CBF values in the healthy control database) was the outcome measure in a logistic regression model that included stenosis grade and location. Results- Logistic regression showed that anterior ( P<0.0001) and middle cerebral artery territory regions ( P=0.003) in Moyamoya patients were susceptible to hypoperfusion, whereas posterior regions were not. Cortical regions supplied by arteries with stenosis on MR angiography showed more hypoperfusion than normal arteries ( P=0.001), but the extent of hypoperfusion was not different between mild-moderate versus severe stenosis. Multidelay ASL did not perform differently from [15O]-water PET in detecting perfusion abnormalities, but standard ASL overestimated the extent of hypoperfusion in patients ( P=0.003). Conclusions- This simultaneous PET/MRI study supports the use of multidelay ASL MRI in clinical evaluation of Moyamoya disease in settings where nuclear medicine imaging is not available and application of a normative perfusion database to automatically identify abnormal CBF in patients.


Asunto(s)
Bases de Datos Factuales , Imagen por Resonancia Magnética , Arteria Cerebral Media , Enfermedad de Moyamoya , Tomografía de Emisión de Positrones , Adolescente , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Arteria Cerebral Media/diagnóstico por imagen , Arteria Cerebral Media/fisiopatología , Enfermedad de Moyamoya/diagnóstico por imagen , Enfermedad de Moyamoya/fisiopatología , Marcadores de Spin
7.
Stroke ; 48(9): 2441-2449, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-28765286

RESUMEN

BACKGROUND AND PURPOSE: Arterial spin labeling (ASL) MRI is a promising, noninvasive technique to image cerebral blood flow (CBF) but is difficult to use in cerebrovascular patients with abnormal, long arterial transit times through collateral pathways. To be clinically adopted, ASL must first be optimized and validated against a reference standard in these challenging patient cases. METHODS: We compared standard-delay ASL (post-label delay=2.025 seconds), multidelay ASL (post-label delay=0.7-3.0 seconds), and long-label long-delay ASL acquisitions (post-label delay=4.0 seconds) against simultaneous [15O]-positron emission tomography (PET) CBF maps in 15 Moyamoya patients on a hybrid PET/MRI scanner. Dynamic susceptibility contrast was performed in each patient to identify areas of mild, moderate, and severe time-to-maximum (Tmax) delays. Relative CBF measurements by each ASL scan in 20 cortical regions were compared with the PET reference standard, and correlations were calculated for areas with moderate and severe Tmax delays. RESULTS: Standard-delay ASL underestimated relative CBF by 20% in areas of severe Tmax delays, particularly in anterior and middle territories commonly affected by Moyamoya disease (P<0.001). Arterial transit times correction by multidelay acquisitions led to improved consistency with PET, but still underestimated CBF in the presence of long transit delays (P=0.02). Long-label long-delay ASL scans showed the strongest correlation relative to PET, and there was no difference in mean relative CBF between the modalities, even in areas of severe delays. CONCLUSIONS: Post-label delay times of ≥4 seconds are needed and may be combined with multidelay strategies for robust ASL assessment of CBF in Moyamoya disease.


Asunto(s)
Encéfalo/diagnóstico por imagen , Circulación Cerebrovascular , Enfermedad de Moyamoya/diagnóstico por imagen , Adolescente , Adulto , Encéfalo/irrigación sanguínea , Circulación Colateral , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Imagen Multimodal , Radioisótopos de Oxígeno , Tomografía de Emisión de Positrones , Marcadores de Spin
8.
AJR Am J Roentgenol ; 209(5): 1136-1142, 2017 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-28777652

RESUMEN

OBJECTIVE: Differences in the attenuation correction methods used in PET/CT scanners versus the newly introduced whole-body simultaneous PET/MRI reportedly result in differences in standardized uptake values (SUVs) in the normal skeleton. The aim of the study was to compare the semiquantitative FDG uptake in the normal skeleton using time-of-flight (TOF) PET/MRI versus PET/CT with and without TOF. SUBJECTS AND METHODS: Participants received a single FDG injection and underwent non-TOF and TOF PET/CT (n = 23) or non-TOF PET/CT and TOF PET/MRI (n = 50). Mean SUV (SUVmean) and maximum SUV (SUVmax) were measured from all PET scans for nine normal regions of the skeleton. Pearson correlation coefficients (r) were used to evaluate the SUVmax and SUVmean of normal skeleton between non-TOF and TOF PET/CT, as well as between non-TOF PET/CT and TOF PET/MRI. In addition, percentage differences in SUVmax and SUVmean of the normal skeleton between non-TOF and TOF PET/CT and between non-TOF PET/CT and TOF PET/MRI were evaluated. RESULTS: The SUVmax and SUVmean in the normal skeleton significantly increased between non-TOF and TOF PET/CT, but they significantly decreased between non-TOF PET/CT and TOF PET/MRI. The SUVmax and SUVmean in normal skeleton showed good correlation between non-TOF PET/CT and TOF PET/MRI (SUVmax, r = 0.88; SUVmean, r = 0.91) and showed a similar trend between non-TOF and TOF PET/CT (SUVmax, r = 0.88; SUVmean, r = 0.94). CONCLUSION: In the normal skeleton, SUVmax and SUVmean showed high correlations between PET/MRI and PET/CT. The MRI attenuation correction used in TOF PET/MRI provides reliable semiquantitative measurements in the normal skeleton.


Asunto(s)
Huesos/diagnóstico por imagen , Huesos/metabolismo , Fluorodesoxiglucosa F18/farmacocinética , Imagen por Resonancia Magnética , Tomografía Computarizada por Tomografía de Emisión de Positrones , Radiofármacos/farmacocinética , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Imagen Multimodal , Estudios Prospectivos , Imagen de Cuerpo Entero
9.
Clin Cancer Res ; 27(23): 6467-6478, 2021 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-34475101

RESUMEN

PURPOSE: Pyruvate kinase M2 (PKM2) catalyzes the final step in glycolysis, a key process of cancer metabolism. PKM2 is preferentially expressed by glioblastoma (GBM) cells with minimal expression in healthy brain. We describe the development, validation, and translation of a novel PET tracer to study PKM2 in GBM. We evaluated 1-((2-fluoro-6-[18F]fluorophenyl)sulfonyl)-4-((4-methoxyphenyl)sulfonyl)piperazine ([18F]DASA-23) in cell culture, mouse models of GBM, healthy human volunteers, and patients with GBM. EXPERIMENTAL DESIGN: [18F]DASA-23 was synthesized with a molar activity of 100.47 ± 29.58 GBq/µmol and radiochemical purity >95%. We performed initial testing of [18F]DASA-23 in GBM cell culture and human GBM xenografts implanted orthotopically into mice. Next, we produced [18F]DASA-23 under FDA oversight, and evaluated it in healthy volunteers and a pilot cohort of patients with glioma. RESULTS: In mouse imaging studies, [18F]DASA-23 clearly delineated the U87 GBM from surrounding healthy brain tissue and had a tumor-to-brain ratio of 3.6 ± 0.5. In human volunteers, [18F]DASA-23 crossed the intact blood-brain barrier and was rapidly cleared. In patients with GBM, [18F]DASA-23 successfully outlined tumors visible on contrast-enhanced MRI. The uptake of [18F]DASA-23 was markedly elevated in GBMs compared with normal brain, and it identified a metabolic nonresponder within 1 week of treatment initiation. CONCLUSIONS: We developed and translated [18F]DASA-23 as a new tracer that demonstrated the visualization of aberrantly expressed PKM2 for the first time in human subjects. These results warrant further clinical evaluation of [18F]DASA-23 to assess its utility for imaging therapy-induced normalization of aberrant cancer metabolism.


Asunto(s)
Neoplasias Encefálicas , Glioblastoma , Animales , Neoplasias Encefálicas/patología , Compuestos de Diazonio , Glioblastoma/patología , Glucólisis , Humanos , Ratones , Tomografía de Emisión de Positrones/métodos , Piruvato Quinasa/metabolismo , Ácidos Sulfanílicos
10.
J Nucl Med ; 60(10): 1340-1346, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31123099

RESUMEN

Since the introduction of simultaneous PET/MRI in 2011, there have been significant advancements. In this review, we highlight several technical advancements that have been made primarily in attenuation and motion correction and discuss the status of multiple clinical applications using PET/MRI. This review is based on the experience at the first PET/MRI conference cosponsored by the International Society for Magnetic Resonance in Medicine and the Society of Nuclear Medicine and Molecular Imaging.


Asunto(s)
Imagen Molecular , Tomografía de Emisión de Positrones , Enfermedades Cardiovasculares/diagnóstico por imagen , Chicago , Epilepsia/diagnóstico por imagen , Diseño de Equipo , Corazón/diagnóstico por imagen , Humanos , Aprendizaje Automático , Imagen por Resonancia Magnética/instrumentación , Oncología Médica/métodos , Imagen Molecular/instrumentación , Movimiento (Física) , Imagen Multimodal , Neoplasias/diagnóstico por imagen , Enfermedades Neurodegenerativas/diagnóstico por imagen , Medicina Nuclear/instrumentación , Tomografía de Emisión de Positrones/instrumentación , Nódulo Pulmonar Solitario/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Investigación Biomédica Traslacional , Flujo de Trabajo
11.
J Nucl Med Technol ; 46(2): 151-152, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29273694

RESUMEN

We present a case of memory loss and aphasia in a 72-y-old man and discuss how PET imaging supported a diagnosis of Alzheimer dementia despite conflicting clinical findings.


Asunto(s)
Enfermedad de Alzheimer/diagnóstico por imagen , Enfermedad de Alzheimer/metabolismo , Amiloide/metabolismo , Fluorodesoxiglucosa F18 , Tomografía de Emisión de Positrones , Anciano , Enfermedad de Alzheimer/complicaciones , Humanos , Masculino , Trastornos de la Memoria/complicaciones
12.
J Nucl Med ; 59(6): 967-972, 2018 06.
Artículo en Inglés | MEDLINE | ID: mdl-29097408

RESUMEN

Chronic sciatica is a major cause of disability worldwide, but accurate diagnosis of the causative pathology remains challenging. In this report, the feasibility of an 18F-FDG PET/MRI approach for improved diagnosis of chronic sciatica is presented. Methods:18F-FDG PET/MRI was performed on 9 chronic sciatica patients and 5 healthy volunteers (healthy controls). Region-of-interest analysis using SUVmax was performed, and 18F-FDG uptake in lesions was compared with that in the corresponding areas in healthy controls. Results: Significantly increased 18F-FDG uptake was observed in detected lesions in all patients and was correlated with pain symptoms. 18F-FDG-avid lesions not only were found in impinged spinal nerves but also were associated with nonspinal causes of pain, such as facet joint degeneration, pars defect, or presumed scar neuroma. Conclusion: The feasibility of 18F-FDG PET/MRI for diagnosing pain generators in chronic sciatica was demonstrated, revealing various possible etiologies.


Asunto(s)
Fluorodesoxiglucosa F18 , Imagen por Resonancia Magnética , Imagen Multimodal , Tomografía de Emisión de Positrones , Ciática/diagnóstico por imagen , Columna Vertebral/diagnóstico por imagen , Adulto , Enfermedad Crónica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Dolor/complicaciones , Ciática/complicaciones , Adulto Joven
13.
PLoS One ; 12(1): e0167262, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28103230

RESUMEN

PURPOSE: To compare the conspicuity of malignant lesions between FDG PET/CT and a new simultaneous, time-of-flight (TOF) enabled PET/MRI scanner. METHODS: All patients underwent a single-injection of FDG, followed by a dual imaging protocol consisting of PET/CT followed by TOF PET/MRI. PET/CT and PET/MRI images were evaluated by two readers independently for areas of FDG uptake compatible with malignancy, and then categorized into 5 groups (1: PET/MRI and PET/CT positive; 2: PET/MRI positive, PET/CT positive in retrospect; 3: PET/CT positive, PET/MRI positive in retrospect; 4: PET/MRI positive, PET/CT negative; 5: PET/MRI negative, PET/CT positive) by consensus. Patients with no lesions on either study or greater than 10 lesions based on either modality were excluded from the study. RESULTS: Fifty-two patients (mean±SD age: 58±14 years) underwent the dual imaging protocol; of these, 29 patients with a total of 93 FDG-avid lesions met the inclusion criteria. The majority of lesions (56%) were recorded prospectively in the same location on PET/CT and PET/MRI. About an equal small fraction of lesions were seen on PET/CT but only retrospectively on PET/MRI (9%) and vice versa (12%). More lesions were identified only on PET/MRI but not on PET/CT, even in retrospect (96% vs. 81%, respectively; p = 0.003). Discrepant lesions had lower maximum standardized uptake value (SUVmax) than concordant lesions on both modalities (p<0.001). CONCLUSIONS: While most lesions were identified prospectively on both modalities, significantly more lesions were identified with PET/MRI than with PET/CT.


Asunto(s)
Imagen por Resonancia Magnética/métodos , Neoplasias/diagnóstico por imagen , Tomografía Computarizada por Tomografía de Emisión de Positrones , Tomografía de Emisión de Positrones/métodos , Adulto , Anciano , Anciano de 80 o más Años , Errores Diagnósticos , Femenino , Fluorodesoxiglucosa F18 , Humanos , Masculino , Persona de Mediana Edad , Imagen Multimodal/métodos , Estudios Prospectivos , Radiofármacos , Estudios Retrospectivos
14.
J Nucl Med ; 58(12): 2004-2009, 2017 12.
Artículo en Inglés | MEDLINE | ID: mdl-28572487

RESUMEN

The purpose of this study was to assess safety, biodistribution, and radiation dosimetry in humans for the highly selective σ-1 receptor PET agent 18F-6-(3-fluoropropyl)-3-(2-(azepan-1-yl)ethyl)benzo[d]thiazol-2(3H)-one (18F-FTC-146). Methods: Ten healthy volunteers (5 women, 5 men; age ± SD, 34.3 ± 6.5 y) were recruited, and written informed consent was obtained from all participants. Series of whole-body PET/MRI examinations were acquired for up to 3 h after injection (357.2 ± 48.8 MBq). Blood samples were collected, and standard vital signs (heart rate, pulse oximetry, and body temperature) were monitored at regular intervals. Regions of interest were delineated, time-activity curves were calculated, and organ uptake and dosimetry were estimated. Results: All subjects tolerated the PET/MRI examination well, and no adverse reactions to 18F-FTC-146 were reported. High accumulation of 18F-FTC-146 was observed in σ-1 receptor-dense organs such as the pancreas and spleen, moderate uptake in the brain and myocardium, and low uptake in bone and muscle. High uptake was also observed in the kidneys and bladder, indicating renal tracer clearance. The effective dose of 18F-FTC-146 was 0.0259 ± 0.0034 mSv/MBq (range, 0.0215-0.0301 mSv/MBq). Conclusion: First-in-human studies with clinical-grade 18F-FTC-146 were successful. Injection of 18F-FTC-146 is safe, and absorbed doses are acceptable. The potential of 18F-FTC-146 as an imaging agent for a variety of neuroinflammatory diseases is currently under investigation.


Asunto(s)
Azepinas/farmacocinética , Benzotiazoles/farmacocinética , Radiofármacos/farmacocinética , Adulto , Azepinas/efectos adversos , Azepinas/síntesis química , Benzotiazoles/efectos adversos , Benzotiazoles/síntesis química , Femenino , Voluntarios Sanos , Humanos , Marcaje Isotópico , Imagen por Resonancia Magnética , Masculino , Imagen Multimodal , Radiometría , Radiofármacos/efectos adversos , Radiofármacos/síntesis química , Receptores sigma/efectos de los fármacos , Receptores sigma/metabolismo , Distribución Tisular , Imagen de Cuerpo Entero , Receptor Sigma-1
15.
Mol Imaging Biol ; 18(5): 776-81, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-26884058

RESUMEN

PURPOSE: An integrated positron emission tomography (PET)/magnetic resonance imaging (MRI) scanner with time of flight (TOF) technology is now available for clinical use. The aim of this study is to evaluate the potential of TOF PET in PET/MRI to reduce artifacts in PET images when compared to non-TOF PET/MRI, TOF PET/X-ray computed tomography (CT), and non-TOF PET/CT. PROCEDURES: All patients underwent a single 2-deoxy-2-[(18)F]fluoro-D-glucose ([(18)F]FDG) injection, followed first by PET/CT, and subsequently by PET/MRI. PET/CT exams were requested as standard-of-care for oncological indications. Using the PET acquisitions datasets, 4 series of images (TOF PET/CT, non-TOF PET/CT, TOF PET/MRI, and non-TOF PET/MRI) were reconstructed. These image series were visually evaluated for: (1) dental metal artifacts, (2) breathing artifacts, and (3) pelvic artifacts due to scatter correction errors from high bladder [(18)F]FDG concentration. PET image quality was assessed by a 3-point scale (1-clinically significant artifact, 2-non clinically significant artifact, and 3-no artifact). RESULTS: Twenty-five patients (mean ± SD age: 56 ± 13 years old; female: 10, male: 15) were enrolled. TOF PET/MRI, non-TOF PET/MRI, TOF PET/CT, and non-TOF PET/CT scores 2.8, 2.5, 2.4, and 2.3, respectively for the presence of dental artifacts, 2.8, 2.5, 2.2, and 1.9, respectively, for the presence of breathing artifacts, and 2.7, 1.7, 2.0, and 1.3, respectively, for the presence of pelvic artifacts TOF PET/MRI images showed the highest image quality scores among the 4 datasets of PET images. CONCLUSION: The superior timing resolution and resulting TOF capability of the new PET/MRI scanner improved PET image quality in this cohort by reducing artifacts compared to non-TOF PET/MRI, TOF PET/CT, and non-TOF PET/CT.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/normas , Imagen por Resonancia Magnética/normas , Tomografía de Emisión de Positrones/normas , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Tomografía de Emisión de Positrones/normas , Factores de Tiempo , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA