Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Cardiovasc Electrophysiol ; 34(8): 1698-1705, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37493499

RESUMEN

INTRODUCTION: Among patients with non-valvular atrial fibrillation (AF) and percutaneous left atrial appendage closure (LAAC) undergoing direct current cardioversion (DCCV), the need for and use of LAA imaging and oral anticoagulation (OAC) is unclear. OBJECTIVE: The purpose of this study is to evaluate the real-world use of transesophageal echocardiography (TEE) or cardiac computed tomography angiography (CCTA) before DCCV and use of OAC pre- and post-DCCV in patients with AF status post percutaneous LAAC. METHODS: This retrospective single center study included all patients who underwent DCCV after percutaneous LAAC from 2016 to 2022. Key measures were completion of TEE or CCTA pre-DCCV, OAC use pre- and post-DCCV, incidence of left atrial thrombus (LAT) or device-related thrombus (DRT), incidence of peri-device leak (PDL), and DCCV-related complications (stroke, systemic embolism, device embolization, major bleeding, or death) within 30 days. RESULTS: A total of 76 patients with AF and LAAC underwent 122 cases of DCCV. LAAC consisted of 47 (62%), 28 (37%), and 1 (1%) case of Watchman 2.5, Watchman FLX, and Lariat, respectively. Among the 122 DCCV cases, 31 (25%) cases were identified as "non-guideline based" due to: (1) no OAC for 3 weeks and no LAA imaging within 48 h before DCCV in 12 (10%) cases, (2) no OAC for 4 weeks following DCCV in 16 (13%) cases, or (3) both in 3 (2%) cases. Among the 70 (57%) cases that underwent TEE or CCTA before DCCV, 16 (23%) cases had a PDL with a mean size of 3.0 ± 1.1 mm, and 4 (6%) cases had a LAT/DRT on TEE resulting in cancellation. There were no DCCV-related complications within 30 days. DISCUSSION: There is a widely varied practice pattern of TEE, CCTA, and OAC use with DCCV after LAAC, with a 6% rate of LAT/DRT. LAA imaging before DCCV appears prudent in all cases, especially within 1 year of LAAC, to assess for device position, PDL, and LAT/DRT.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Cardiopatías , Accidente Cerebrovascular , Trombosis , Humanos , Estudios Retrospectivos , Cardioversión Eléctrica/efectos adversos , Apéndice Atrial/diagnóstico por imagen , Trombosis/diagnóstico por imagen , Trombosis/etiología , Trombosis/prevención & control , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/terapia , Ecocardiografía Transesofágica , Resultado del Tratamiento , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Cateterismo Cardíaco/efectos adversos
2.
Pacing Clin Electrophysiol ; 46(7): 745-751, 2023 07.
Artículo en Inglés | MEDLINE | ID: mdl-37221927

RESUMEN

BACKGROUND: Transesophageal echocardiography (TEE) and cardiac computed tomography angiography (CCTA) are currently utilized for left atrial appendage closure (LAAC) planning. During the recent global iodine contrast media shortage in 2022, cardiac magnetic resonance imaging (CMR) was utilized for the first time for LAAC planning. This study sought to assess the utility of CMR versus TEE for LAAC planning. METHODS: This single center retrospective study consisted of all patients who underwent preoperative CMR for LAAC with Watchman FLX or Amplatzer Amulet. Key measures were accuracy of LAA thrombus exclusion, ostial diameter, depth, lobe count, morphology, accuracy of predicted device size, and devices deployed per case. Bland-Altman Analysis was used to compare CMR versus TEE measurements of LAA ostial diameter and depth. RESULTS: 25 patients underwent preoperative CMR for LAAC planning. A total of 24 (96%) cases were successfully completed with 1.2 ± 0.5 devices deployed per case. Among the 18 patients who underwent intraoperative TEE, there was no significant difference between CMR versus TEE in LAA thrombus exclusion (CMR 83% vs. TEE 100% cases, p = .229), lobe count (CMR 1.7 ± 0.8 vs. TEE 1.4 ± 0.6, p = .177), morphology (p = .422), and accuracy of predicted device size (CMR 67% vs. TEE 72% cases, p = 1.000). When comparing the difference between CMR and TEE measurements, Bland-Altman analysis demonstrated no significant difference in LAA ostial diameter (CMR-TEE bias 0.7 mm, 95% CI [-1.1, 2.4], p = .420), but LAA depth was significantly larger with CMR versus TEE (CMR-TEE bias 7.4 mm, 95% CI [1.6, 13.2], p = .015). CONCLUSIONS: CMR is a promising alternative for LAAC planning in cases where TEE or CCTA are contraindicated or unavailable.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Trombosis , Humanos , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Estudios Retrospectivos , Ecocardiografía Transesofágica/métodos , Imagen por Resonancia Magnética , Trombosis/diagnóstico por imagen , Cateterismo Cardíaco , Resultado del Tratamiento
3.
J Mol Cell Cardiol ; 151: 56-71, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33130148

RESUMEN

Atrial fibrillation (AF) occurrence and maintenance is associated with progressive remodeling of electrophysiological (repolarization and conduction) and 3D structural (fibrosis, fiber orientations, and wall thickness) features of the human atria. Significant diversity in AF etiology leads to heterogeneous arrhythmogenic electrophysiological and structural substrates within the 3D structure of the human atria. Since current clinical methods have yet to fully resolve the patient-specific arrhythmogenic substrates, mechanism-based AF treatments remain underdeveloped. Here, we review current knowledge from in-vivo, ex-vivo, and in-vitro human heart studies, and discuss how these studies may provide new insights on the synergy of atrial electrophysiological and 3D structural features in AF maintenance. In-vitro studies on surgically acquired human atrial samples provide a great opportunity to study a wide spectrum of AF pathology, including functional changes in single-cell action potentials, ion channels, and gene/protein expression. However, limited size of the samples prevents evaluation of heterogeneous AF substrates and reentrant mechanisms. In contrast, coronary-perfused ex-vivo human hearts can be studied with state-of-the-art functional and structural technologies, such as high-resolution near-infrared optical mapping and contrast-enhanced MRI. These imaging modalities can resolve atrial arrhythmogenic substrates and their role in reentrant mechanisms maintaining AF and validate clinical approaches. Nonetheless, longitudinal studies are not feasible in explanted human hearts. As no approach is perfect, we suggest that combining the strengths of direct human atrial studies with high fidelity approaches available in the laboratory and in realistic patient-specific computer models would elucidate deeper knowledge of AF mechanisms. We propose that a comprehensive translational pipeline from ex-vivo human heart studies to longitudinal clinically relevant AF animal studies and finally to clinical trials is necessary to identify patient-specific arrhythmogenic substrates and develop novel AF treatments.


Asunto(s)
Fibrilación Atrial/fisiopatología , Fenómenos Electrofisiológicos , Atrios Cardíacos/patología , Atrios Cardíacos/fisiopatología , Imagenología Tridimensional , Miocardio/patología , Inteligencia Artificial , Humanos
4.
J Cardiovasc Electrophysiol ; 32(11): 3027-3034, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34554620

RESUMEN

INTRODUCTION: Defibrillation testing (DT) is recommended during the subcutaneous defibrillator (S-ICD) placement. We sought to compare 10 J shock impedance in sinus rhythm (SR) with 65 J defibrillation impedance and evaluate device position on a postimplant chest X-ray (CXR) using an intermuscular (IM) technique. METHODS: Consecutive S-ICD implantations between 12/2019 and 12/2020 at The Ohio State University were reviewed. All implantations were performed using a two-incision IM technique. Standard DT with 65 J shock and 10 J shock in SR were performed unless contraindicated. The PRAETORIAN score was calculated based on CXR. RESULTS: A total of 37 patients (age: 47.2 ± 15.8 years old, male: n = 26 [70.3%], body mass index: 30.1 ± 6.7 kg/m2 ) underwent IM S-ICD implantation, and of those, 27 (73%) underwent both 65 J shock and 10 J shock in SR. The coefficient of determination (R2 ) between 10 J shock impedance and 65 J shock impedance was 0.84. The mean of an impedance difference was 1.6 ± 4.8 Ω (minimum - 11 and maximum 8). Postimplant CXR was available for 33 out of 37 patients (89.2%). The PRAETORIAN score was less than 90 in all patients and the mean score was 32.7 ± 8.8. CONCLUSION: We demonstrated that 10 J shock impedance in SR correlated well with 65 J defibrillation impedance during IM S-ICD implantation. An IM implantation technique provides excellent generator location on postimplant CXR. The IM technique combined with 10 J shock in SR may be sufficient to predict and ensure the defibrillation efficacy of the S-ICD.


Asunto(s)
Desfibriladores Implantables , Adulto , Arritmias Cardíacas , Cardioversión Eléctrica , Impedancia Eléctrica , Humanos , Masculino , Persona de Mediana Edad , Ohio , Tejido Subcutáneo
5.
J Cardiovasc Electrophysiol ; 32(2): 477-483, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33205561

RESUMEN

INTRODUCTION: Frequent right AQ4ventricular pacing (≥40%) with a transvenous pacemaker (TVP) is associated with the risk of pacing-induced cardiomyopathy (PICM). Leadless pacemakers (LPs) have distinct physical and mechanical differences from TVP. The risk of PICM with LP is not known. To identify incidence, predictors, and long-term outcomes of PICM in LP and TVP patients. METHODS: The study comprised all pacemaker-dependent patients with LP or TVP who had left ventricular ejection fraction (LVEF) of ≥50 from 2014 to 2019. The incidence of PICM (≥10% LVEF drop) was assessed with an echocardiogram. Predictors for PICM were identified using multivariate analysis. Long-term outcomes after cardiac resynchronization (CRT) were assessed in both groups. RESULTS: A total of 131 patients with TVP and 67 with LP comprised the study. All patients in the TVP group and the majority in the LP group underwent atrioventricular node ablation. The mean follow-up duration in TVP and LP groups was 592 ± 549 and 817 ± 600 days, respectively. A total of 18 (13.7%) patients in TVP and 2 (3%) in LP developed PICM after a median duration of 254 (interquartile range: 470) days. The incidence of PICM was significantly higher with TVP compared with LP (p = .02). TVP as pacing modality was a positive (odds ratio [OR]: 1.07) while age was negative (OR: 0.94) predictor for PICM on multivariable analysis. Both patients in LP and all except two in the TVP group responded to CRT. CONCLUSION: Incidence of PICM is significantly lower with LP compared with TVP in pacemaker-dependent patients. Age and TVP as pacing modality were predictors for PICM.


Asunto(s)
Cardiomiopatías , Marcapaso Artificial , Estimulación Cardíaca Artificial/efectos adversos , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/epidemiología , Humanos , Incidencia , Marcapaso Artificial/efectos adversos , Estudios Retrospectivos , Volumen Sistólico , Función Ventricular Izquierda
6.
J Cardiovasc Electrophysiol ; 30(11): 2453-2459, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31502324

RESUMEN

BACKGROUND: An internal risk stratification algorithm was developed to decrease the risk of major adverse cardiac events (MACEs) during lead extractions (LEs). OBJECTIVE: To report upon the impact of a risk stratification algorithm (RISE [RIsk Stratification prior to lead Extraction] protocol) on outcomes of LEs in a high-volume center. METHODS: A retrospective review of a prospectively maintained LEs database was performed to identify features associated with MACEs. On the basis of the retrospective data, the RISE protocol differentiated LEs procedures into "High" and "Low" risk for occurrence of MACEs. High-risk LEs included dual-coil defibrillator lead (≥3 years), pacemaker and single-coil lead (≥5 years), and any StarFix coronary sinus lead. During the prospective evaluation of the RISE protocol, "High-risk" LEs were performed in an operating room (OR) or hybrid laboratory with the cardiac anesthesiologist, OR nursing team, perfusionist in the room, and a cardiac surgeon on the premises. "Low-risk" LEs were performed in the electrophysiology (EP) laboratory with anesthesia provided by EP nursing team. The preintervention (pre-RISE) and postintervention (post-RISE) group spanned 19 and 40 months and consisted of 449 (632 leads) and 751 patients (1055 leads), respectively. The primary outcome of MACEs in the two groups was compared. RESULTS: Protocol compliance was 100%. The primary outcome of MACEs occurred in 15 patients (3.34%) before and 12 (1.6%) after implementation of the RISE protocol (P = .04). CONCLUSION: RISE identified a low-risk group where minimal resources are needed and allowed for rapid intervention in the high-risk group that reduced the consequences of MACEs.


Asunto(s)
Protocolos Clínicos , Desfibriladores Implantables , Remoción de Dispositivos/efectos adversos , Marcapaso Artificial , Complicaciones Posoperatorias/prevención & control , Anciano , Anciano de 80 o más Años , Bases de Datos Factuales , Remoción de Dispositivos/mortalidad , Femenino , Hospitales de Alto Volumen , Humanos , Masculino , Persona de Mediana Edad , Ohio , Complicaciones Posoperatorias/mortalidad , Estudios Prospectivos , Diseño de Prótesis , Mejoramiento de la Calidad , Indicadores de Calidad de la Atención de Salud , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
7.
Europace ; 21(11): 1686-1693, 2019 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-31681964

RESUMEN

AIMS: Patient selection is a key component of securing optimal patient outcomes with leadless pacing. We sought to describe and compare patient characteristics and outcomes of Micra patients with and without a primary pacing indication associated with atrial fibrillation (AF) in the Micra IDE trial. METHODS AND RESULTS: The primary outcome (risk of cardiac failure, pacemaker syndrome, or syncope related to the Micra system or procedure) was compared between successfully implanted patients from the Micra IDE trial with a primary pacing indication associated with AF or history of AF (AF group) and those without (non-AF group). Among 720 patients successfully implanted with Micra, 228 (31.7%) were in the non-AF group. Reasons for selecting VVI pacing in non-AF patients included an expectation for infrequent pacing (66.2%) and advanced age (27.2%). More patients in the non-AF group had a condition that precluded the use of a transvenous pacemaker (9.6% vs. 4.7%, P = 0.013). Atrial fibrillation patients programmed to VVI received significantly more ventricular pacing compared to non-AF patients (median 67.8% vs. 12.6%; P < 0.001). The overall occurrence of the composite outcome at 24 months was 1.8% with no difference between the AF and non-AF groups (hazard ratio 1.36, 95% confidence interval 0.45-4.2; P = 0.59). CONCLUSION: Nearly one-third of patients selected to receive Micra VVI therapy were for indications not associated with AF. Non-AF VVI patients required less frequent pacing compared to patients with AF. Risks associated with VVI therapy were low and did not differ in those with and without AF.


Asunto(s)
Fibrilación Atrial/terapia , Estimulación Cardíaca Artificial/métodos , Ventrículos Cardíacos/fisiopatología , Marcapaso Artificial , Selección de Paciente , Anciano , Fibrilación Atrial/fisiopatología , Diseño de Equipo , Femenino , Humanos , Masculino , Estudios Prospectivos , Resultado del Tratamiento
8.
Pacing Clin Electrophysiol ; 42(1): 58-62, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-30414285

RESUMEN

BACKGROUND: Lead dislodgement (LD) is a well-recognized complication during implantation of cardiac implantable electronic devices (CIEDs). An intraprocedural protocol, referred to as reduction of LD protocol, was developed to reduce the risk of LD. METHODS: The protocol involved (1) inserting a straight stylet down the right atrial lead and applying forward pressure while monitoring for fluoroscopic stability, (2) visualizing all leads during deep inspiration to determine if there is adequate lead redundancy, and (3) having the patient take a deep breath and cough while pacing just at capture threshold to assess for loss of capture in each lead. Any intraprocedural change in the parameters fulfilling the predefined criteria for inadequate lead implantation prompted lead repositioning. Data regarding demographic factors, clinical characteristics, and incidence of LD in the first 30 days after implant was obtained from intramural CIED database. The preintervention (control) group spanned 27 months and consisted of a total of 4,294 leads while the postintervention (intervention) group spanned 17 months and consisted of 2,361 leads implanted. RESULTS: There was no significant difference in the demographic factors and clinical characteristics in the two groups. Protocol compliance was > 90%. There were 44 occurrences of LD (1.02%) before and 10 (0.4%) after implementation of the protocol. The protocol significantly reduced the incidence of LD during the 30 days after implant (P = 0.014). No clinical characteristic predicted the risk of LD. CONCLUSION: Intraprocedural maneuvers performed to assess the adequacy of lead implantation results in reduced risk of LD.


Asunto(s)
Dispositivos de Terapia de Resincronización Cardíaca , Electrodos Implantados , Falla de Equipo , Complicaciones Posoperatorias/prevención & control , Anciano , Electrocardiografía , Femenino , Fluoroscopía , Humanos , Masculino , Estudios Prospectivos , Estudios Retrospectivos , Factores de Riesgo
9.
Pacing Clin Electrophysiol ; 42(12): 1552-1557, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31702059

RESUMEN

BACKGROUND: The perioperative anesthesia care during subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation is still evolving. OBJECTIVE: To assess the feasibility and safety of S-ICD implantation with monitored anesthesia care (MAC) versus general anesthesia (GA) in a tertiary care center. METHODS: This is a single-center retrospective study of patients undergoing S-ICD implantation between October 2012 and May 2019. Patients were categorized into MAC and GA group based on the mode of anesthesia. Procedural success without escalation to GA was the primary endpoint of the study, whereas intraprocedural hemodynamics, need of pharmacological support for hypotension and bradycardia, length of the procedure, stay in the post-anesthesia care unit, and postoperative pain were assessed as secondary endpoints. RESULTS: The study comprises 287 patients with MAC in 111 and GA in 176 patients. Compared to MAC, patients in GA group were younger and had a higher body mass index. All patients had successful S-ICD implantation. Only one patient (0.9%) in the MAC group was converted to GA. Despite a similar baseline heart rate (HR) and mean arterial blood pressure (MAP) in both groups, patients with GA had significantly lower HR and MAP during the procedure and more frequently required pharmacological hemodynamic support. Length of the procedure, stay in the postanesthesia care unit, and postoperative pain was similar in both groups. CONCLUSION: This retrospective experience suggests that implantation of S-ICD is feasible and safe with MAC. Use of GA is associated with more frequent administration of hemodynamic drugs during S-ICD implantation.


Asunto(s)
Anestesia/métodos , Desfibriladores Implantables , Implantación de Prótesis/métodos , Anestesia General , Anestesia Local , Bradicardia/tratamiento farmacológico , Estudios de Factibilidad , Femenino , Hemodinámica , Humanos , Hipotensión/tratamiento farmacológico , Tiempo de Internación/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Tempo Operativo , Dimensión del Dolor , Dolor Postoperatorio/prevención & control , Estudios Retrospectivos
10.
J Cardiovasc Electrophysiol ; 29(10): 1460-1466, 2018 10.
Artículo en Inglés | MEDLINE | ID: mdl-29964312

RESUMEN

BACKGROUND: Cardiac implantable electronic device (CIED) infections associated with large, mobile vegetation adds to the complexity of lead extraction and is associated with significant patient morbidity and mortality. OBJECTIVE: To show the feasibility of concomitant cardiovascular implantable electronic device extraction and vacuum-assisted removal of lead-related vegetations. METHODS: This is a single-center retrospective case series of consecutive patients with persistent bacteremia, sepsis, or endocarditis despite medical therapy who have vegetations >2 cm and subsequently underwent immediate CIED lead extraction after debulking with vacuum-assisted suction. RESULTS: Eight patients underwent successful removal of 17 leads immediately after debulking of vegetations with vacuum-assisted device suction. Debulking procedure was not successful in 1 patient due to inability to direct the vacuum suction device into proper position. There were no intraprocedure complications related to the vacuum-assisted debulking. One patient required open sternotomy for tear of the coronary sinus ostium related to extraction of a left ventricular pacing electrode. There was no mortality within 30 days of the procedure. CONCLUSIONS: Based upon these clinical results, it is feasible for patients with infected CIED systems that have large right-sided vegetations to undergo vacuum-assisted debulking then immediately followed by percutaneous CIED removal in whom surgical removal is considered high risk.


Asunto(s)
Procedimientos Quirúrgicos Cardíacos/efectos adversos , Procedimientos Quirúrgicos Cardíacos/instrumentación , Procedimientos Quirúrgicos de Citorreducción/métodos , Remoción de Dispositivos/métodos , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/instrumentación , Infecciones Relacionadas con Prótesis/terapia , Adulto , Anciano , Procedimientos Quirúrgicos de Citorreducción/efectos adversos , Remoción de Dispositivos/efectos adversos , Ecocardiografía Transesofágica , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/microbiología , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Succión , Resultado del Tratamiento , Vacio , Adulto Joven
12.
Pacing Clin Electrophysiol ; 41(5): 504-510, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-29476660

RESUMEN

BACKGROUND: Atrioventricular junctional (AVJ) ablation and pacemaker implantation are indicated when pharmacotherapy fails to achieve adequate rate control in atrial fibrillation (AF). The purpose of our study is to assess the feasibility and safety of concurrent Micra leadless transcatheter pacemaker implantation and AVJ ablation. METHODS: We retrospectively assessed patients who underwent Micra implantation and concurrent AVJ ablation at three institutions between August 2014 and March 2016. All patients and devices were followed at baseline and at 1, 3, 6, and 12 months postimplantion. RESULTS: Twenty-one patients with permanent AF (median age 77 [range: 62-88], female 15 [71.4%]) underwent successful Micra implantation followed by concurrent AVJ ablation. There was no device dislodgement or malfunction during the 12-month follow-up. Complete 12-month electrical performance data were available in 14 patients (67%). Among patients with the complete data set, median pacing thresholds at implant and at 1, 3, 6, and 12 months were 0.5 V (range: 0.25-0.88), 0.44 V (range: 0.25-2.0), 0.5 V (range: 0.25-1.63), 0.5 V (range: 0.25-1.13), and 0.5 V (range: 0.25-1.13) at a pulse width of 0.24 msec, respectively. Two patients died due to noncardiac causes during follow-up. There were no patients with major device-related complications. CONCLUSIONS: Concurrent Micra implantation and AVJ ablation is feasible and appears safe. There was no device dislodgement, malfunction, or significant pacing threshold rise requiring device reimplantation during the 12-month follow-up. This combined approach can be considered for patients with AF with suboptimal rate control who have failed AF catheter ablation and/or pharmacotherapy.


Asunto(s)
Fibrilación Atrial/cirugía , Nodo Atrioventricular/cirugía , Ablación por Catéter/métodos , Marcapaso Artificial , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/fisiopatología , Nodo Atrioventricular/fisiopatología , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento
13.
Circulation ; 134(6): 486-98, 2016 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-27462069

RESUMEN

BACKGROUND: Adenosine provokes atrial fibrillation (AF) with a higher activation frequency in right atria (RA) versus left atria (LA) in patients, but the underlying molecular and functional substrates are unclear. We tested the hypothesis that adenosine-induced AF is driven by localized reentry in RA areas with highest expression of adenosine A1 receptor and its downstream GIRK (G protein-coupled inwardly rectifying potassium channels) channels (IK,Ado). METHODS: We applied biatrial optical mapping and immunoblot mapping of various atrial regions to reveal the mechanism of adenosine-induced AF in explanted failing and nonfailing human hearts (n=37). RESULTS: Optical mapping of coronary-perfused atria (n=24) revealed that adenosine perfusion (10-100 µmol/L) produced more significant shortening of action potential durations in RA (from 290±45 to 239±41 ms, 17.3±10.4%; P<0.01) than LA (from 307±24 to 286±23 ms, 6.7±6.6%; P<0.01). In 10 hearts, adenosine induced AF (317±116 s) that, when sustained (≥2 minutes), was primarily maintained by 1 to 2 localized reentrant drivers in lateral RA. Tertiapin (10-100 nmol/L), a selective GIRK channel blocker, counteracted adenosine-induced action potential duration shortening and prevented AF induction. Immunoblotting showed that the superior/middle lateral RA had significantly higher adenosine A1 receptor (2.7±1.7-fold; P<0.01) and GIRK4 (1.7±0.8-fold; P<0.05) protein expression than lateral/posterior LA. CONCLUSIONS: This study revealed a 3-fold RA-to-LA adenosine A1 receptor protein expression gradient in the human heart, leading to significantly greater RA versus LA repolarization sensitivity in response to adenosine. Sustained adenosine-induced AF is maintained by reentrant drivers localized in lateral RA regions with the highest adenosine A1 receptor/GIRK4 expression. Selective atrial GIRK channel blockade may effectively treat AF during conditions with increased endogenous adenosine.


Asunto(s)
Adenosina/toxicidad , Fibrilación Atrial/inducido químicamente , Fibrilación Atrial/metabolismo , Canales de Potasio Rectificados Internamente Asociados a la Proteína G/biosíntesis , Atrios Cardíacos/metabolismo , Receptor de Adenosina A1/biosíntesis , Adulto , Anciano , Femenino , Regulación de la Expresión Génica , Corazón/diagnóstico por imagen , Corazón/efectos de los fármacos , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/efectos de los fármacos , Sistema de Conducción Cardíaco/diagnóstico por imagen , Sistema de Conducción Cardíaco/efectos de los fármacos , Sistema de Conducción Cardíaco/metabolismo , Humanos , Masculino , Persona de Mediana Edad , Técnicas de Cultivo de Órganos , Tomografía Computarizada por Tomografía de Emisión de Positrones
14.
Pacing Clin Electrophysiol ; 40(8): 975-976, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28213895

RESUMEN

A 61-year-old woman with symptomatic complete heart block was referred for permanent pacemaker. The presence of a left-sided arteriovenous fistula and right-sided mastectomy with lymph node dissection precluded the implantation of a transvenous pacemaker, and therefore, a leadless pacemaker was recommended. The patient also had an inferior vena cava (IVC) filter. The passage of a 27-French introducer sheath housing the leadless pacemaker through IVC filter was carefully visualized under fluoroscopy and advanced to the right ventricle without any compromise to the filter. This case report shows the safety of passage of large sheaths via the IVC filter.


Asunto(s)
Marcapaso Artificial , Filtros de Vena Cava , Vena Cava Inferior , Diseño de Equipo , Femenino , Humanos , Persona de Mediana Edad , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/métodos
16.
Pacing Clin Electrophysiol ; 39(11): 1246-1253, 2016 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-27549013

RESUMEN

BACKGROUND: Left ventricular lead (LVL) implant success rates have historically ranged between 70.5% and 95.5%. To date, there are few large studies that evaluate LVL implant success utilizing a single family of delivery catheters and leads. The Attain Success study was a prospective nonrandomized multicenter global study with the main objectives of assessing single-system LVL implant success and complication rates. METHODS: Patients undergoing cardiac resynchronization therapy implantation were eligible for enrollment. There was no prespecified level of experience for investigator participation. LVL implant success and complication rates were assessed though 3 months of follow-up. RESULTS: A total of 2,014 patients (69.1 ± 12.0 years, 71% male and 38% atrial fibrillation) were enrolled from 114 centers with a follow-up of 3.5 ± 2.1 months. Coronary sinus cannulation success rate was 96.4% with Attain Family delivery catheters. Implant success rate for Attain Family leads using Attain Family catheters was 94.0%; overall LVL implant success rate was 97.1%. Median procedure time was 4 minutes for cannulation and 9 minutes for LVL placement. Median fluoroscopy time was 17 minutes and median contrast used was 25 cc. There were 55 catheter or LVL-related complications in 53 subjects; the majority were LVL dislodgements (34, 1.7%) and extracardiac stimulation (11, 0.5%). The Kaplan-Meier estimate of the 3-month complication probability was 2.6%. CONCLUSION: This study represents the largest prospective evaluation of LVL implantation to date, revealing a high LVL implant success rate and low complication rate using a single family of leads and delivery catheters.


Asunto(s)
Terapia de Resincronización Cardíaca , Prótesis e Implantes , Anciano , Femenino , Estudios de Seguimiento , Ventrículos Cardíacos , Humanos , Masculino , Complicaciones Posoperatorias , Estudios Prospectivos , Resultado del Tratamiento
17.
Eur Heart J ; 36(35): 2390-401, 2015 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-26059724

RESUMEN

AIMS: The complex architecture of the human atria may create physical substrates for sustained re-entry to drive atrial fibrillation (AF). The existence of sustained, anatomically defined AF drivers in humans has been challenged partly due to the lack of simultaneous endocardial-epicardial (Endo-Epi) mapping coupled with high-resolution 3D structural imaging. METHODS AND RESULTS: Coronary-perfused human right atria from explanted diseased hearts (n = 8, 43-72 years old) were optically mapped simultaneously by three high-resolution CMOS cameras (two aligned Endo-Epi views (330 µm2 resolution) and one panoramic view). 3D gadolinium-enhanced magnetic resonance imaging (GE-MRI, 80 µm3 resolution) revealed the atrial wall structure varied in thickness (1.0 ± 0.7-6.8 ± 2.4 mm), transmural fiber angle differences, and interstitial fibrosis causing transmural activation delay from 23 ± 11 to 43 ± 22 ms at increased pacing rates. Sustained AF (>90 min) was induced by burst pacing during pinacidil (30-100 µM) perfusion. Dual-sided sub-Endo-sub-Epi optical mapping revealed that AF was driven by spatially and temporally stable intramural re-entry with 107 ± 50 ms cycle length and transmural activation delay of 67 ± 31 ms. Intramural re-entrant drivers were captured primarily by sub-Endo mapping, while sub-Epi mapping visualized re-entry or 'breakthrough' patterns. Re-entrant drivers were anchored on 3D micro-anatomic tracks (15.4 ± 2.2 × 6.0 ± 2.3 mm2, 2.9 ± 0.9 mm depth) formed by atrial musculature characterized by increased transmural fiber angle differences and interstitial fibrosis. Targeted radiofrequency ablation of the tracks verified these re-entries as drivers of AF. CONCLUSIONS: Integrated 3D structural-functional mapping of diseased human right atria ex vivo revealed that the complex atrial microstructure caused significant differences between Endo vs. Epi activation during pacing and sustained AF driven by intramural re-entry anchored to fibrosis-insulated atrial bundles.


Asunto(s)
Fibrilación Atrial/patología , Atrios Cardíacos/patología , Adulto , Anciano , Fibrilación Atrial/etiología , Fibrilación Atrial/fisiopatología , Técnicas de Imagen Cardíaca , Medios de Contraste , Mapeo Epicárdico/métodos , Gadolinio , Atrios Cardíacos/fisiopatología , Humanos , Angiografía por Resonancia Magnética/métodos , Persona de Mediana Edad
20.
J Cardiovasc Electrophysiol ; 25(9): 921-929, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24948520

RESUMEN

INTRODUCTION: The success of pulmonary vein isolation (PVI) for atrial fibrillation (AF) may be improved if stable AF sources identified by Focal Impulse and Rotor Mapping (FIRM) are also eliminated. The long-term results of this approach are unclear outside the centers where FIRM was developed; thus, we assessed outcomes of FIRM-guided AF ablation in the first cases at 10 experienced centers. METHODS: We prospectively enrolled n = 78 consecutive patients (61 ± 10 years) undergoing FIRM guided ablation for persistent (n = 48), longstanding persistent (n = 7), or paroxysmal (n = 23) AF. AF recordings from both atria with a 64-pole basket catheter were analyzed using a novel mapping system (Rhythm View(TM) ; Topera Inc., CA, USA). Identified rotors/focal sources were ablated, followed by PVI. RESULTS: Each institution recruited a median of 6 patients, each of whom showed 2.3 ± 0.9 AF rotors/focal sources in diverse locations. 25.3% of all sources were right atrial (RA), and 50.0% of patients had ≥1 RA source. Ablation of all sources required a total of 16.6 ± 11.7 minutes, followed by PVI. On >1 year follow-up with a 3-month blanking period, 1 patient lost to follow-up (median time to 1st recurrence: 245 days, IQR 145-354), single-procedure freedom from AF was 87.5% (patients without prior ablation; 35/40) and 80.5% (all patients; 62/77) and similar for persistent and paroxysmal AF (P = 0.89). CONCLUSIONS: Elimination of patient-specific AF rotors/focal sources produced freedom-from-AF of ≈80% at 1 year at centers new to FIRM. FIRM-guided ablation has a rapid learning curve, yielding similar results to original FIRM reports in each center's first cases.


Asunto(s)
Fibrilación Atrial/fisiopatología , Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sistema de Registros , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA