Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 164
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Clin Chem Lab Med ; 62(5): 958-966, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38000045

RESUMEN

OBJECTIVES: White blood cell (WBC)-related flags are essential for detecting abnormal cells including blasts in automated hematology analyzers (AHAs). Cell population data (CPD) may characterize each WBC population, and customized CPD rules can be also useful for detecting blasts. We evaluated the performance of WBC-related flags, customized CPD rules, and their combination for detecting blasts on the Beckman Coulter DxH 900 AHA (DxH 900, Beckman Coulter, Miami, Florida, USA). METHODS: In a total of 239 samples from patients with hematologic diseases, complete blood count on DxH 900 and manual slide review (MSR) were conducted. The sensitivity, specificity, and efficiency of the five WBC-related flags, nine customized CPD rules, and their combination were evaluated for detecting blasts, in comparison with MSR. RESULTS: Blasts were detected by MSR in 40 out of 239 (16.7 %) samples. The combination of flags and CPD rules showed the highest sensitivity compared with each of flags and CPD rules for detecting blasts (97.5 vs. 72.5 % vs. 92.5 %). Compared with any flag, the combination of flags and CPD rules significantly reduced false-negative samples from 11 to one for detecting blasts (27.5 vs. 2.5 %, p=0.002). CONCLUSIONS: This is the first study that evaluated the performance of both flags and CPD rules on DxH 900. The customized CPD rules as well as the combination of flags and CPD rules outperformed WBC-related flags for detecting blasts on DxH 900. The customized CPD rules can play a complementary role for improving the capability of blast detection on DxH 900.


Asunto(s)
Enfermedades Hematológicas , Hematología , Humanos , Recuento de Células Sanguíneas , Enfermedades Hematológicas/diagnóstico , Leucocitos , Recuento de Leucocitos
2.
Medicina (Kaunas) ; 60(4)2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38674258

RESUMEN

Background and Objectives: The European Kidney Function Consortium (EKFC) equation has been newly proposed for estimating glomerular filtration rate (eGFR) across the spectrum of age. We compared the EKFC equation with the Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations in a large-scale Korean population. Materials and Methods: Using the representative Korean health examination data, the Korea National Health and Nutrition Examination Survey (KNHANES 2008-2021), the records of 91,928 subjects (including 9917 children) were analyzed. We compared the EKFC equation with CKiD, CKD-EPI 2009, and CKD-EPI 2021 equations and investigated their agreement across GFR categories. Results: In the total population, the CKD-EPI 2021 equation yielded the highest eGFR value, followed by the CKD-EPI 2009 and EKFC equations. In children, the distribution of eGFR differed significantly between the EKFC and CKiD equations (p < 0.001), with a wider range of eGFR values found with the CKiD equation. Each equation showed weak or moderate agreement on the frequency of the GFR category (κ = 0.54 between EKFC and CKD-EPI 2021; κ = 0.77 between EKFC and CKD-EPI 2009). The eGFR values found by the EKFC equation showed high or very high correlations with those by the CKiD, CKD-EPI 2009, and CKD-EPI 2021 equations (r = 0.85, 0.97, and 0.97, respectively). As eGFR values increased, bigger differences were observed between equations. Conclusions: This large-scale study demonstrates that the EKFC equation would be applicable across the entire age spectrum in Asian populations. It also underscores that national kidney health would be highly affected by an eGFR equation being implemented. Additional investigation and more caution would be warranted for the transition of eGFR equations.


Asunto(s)
Tasa de Filtración Glomerular , Encuestas Nutricionales , Insuficiencia Renal Crónica , Humanos , República de Corea/epidemiología , Masculino , Femenino , Insuficiencia Renal Crónica/fisiopatología , Insuficiencia Renal Crónica/epidemiología , Niño , Adulto , Persona de Mediana Edad , Adolescente , Anciano , Pruebas de Función Renal/métodos , Pruebas de Función Renal/estadística & datos numéricos , Pruebas de Función Renal/normas , Preescolar , Adulto Joven
3.
Clin Chem Lab Med ; 61(1): 133-141, 2023 01 27.
Artículo en Inglés | MEDLINE | ID: mdl-36306547

RESUMEN

OBJECTIVES: CellaVision DC-1 (DC-1, Sysmex, Kobe, Japan) is a newly launched digital morphology analyzer that was developed mainly for small to medium-volume laboratories. We evaluated the precision, qualitative performance, comparison of cell counts between DC-1 and manual counting, and turnaround time (TAT) of DC-1. METHODS: Using five peripheral blood smear (PBS) slides spanning normal white blood cell (WBC) range, precision and qualitative performance of DC-1 were evaluated according to the Clinical and Laboratory Standards Institute (CLSI) EP15-A3, EP15-Ed3-IG1, and EP12-A2 guidelines. Cell counts of DC-1 and manual counting were compared according to the CLSI EP 09C-ED3 guidelines, and TAT of DC-1 was also compared with TAT of manual counting. RESULTS: DC-1 showed excellent precision (%CV, 0.0-3.5%), high specificity (98.9-100.0%), and high negative predictive value (98.4-100.0%) in 18 cell classes (12 WBC classes and six non-WBC classes). However, DC-1 showed 0% of positive predictive value in seven cell classes (metamyelocytes, myelocytes, promyelocytes, blasts, plasma cells, nucleated red blood cells, and unidentified). The largest absolute mean differences (%) of DC-1 vs. manual counting was 2.74. Total TAT (min:s) was comparable between DC-1 (8:55) and manual counting (8:55). CONCLUSIONS: This is the first study that comprehensively evaluated the performance of DC-1 including its TAT. DC-1 has a reliable performance that can be used in small to medium-volume laboratories for assisting PBS review. However, DC-1 may make unnecessary workload for cell verification in some cell classes.


Asunto(s)
Leucocitos , Humanos , Recuento de Leucocitos , Recuento de Células Sanguíneas , Recuento de Eritrocitos , Valores de Referencia , Reproducibilidad de los Resultados
4.
Clin Chem Lab Med ; 61(10): 1858-1866, 2023 09 26.
Artículo en Inglés | MEDLINE | ID: mdl-37084402

RESUMEN

OBJECTIVES: The EasyCell assistant (Medica, Bedford, MA, USA) is one of the state-of-the-art digital morphology analyzers. We explored the performance of EasyCell assistant in comparison with manual microscopic review and Pentra DX Nexus (Horiba ABX Diagnostics, Montpellier, France). METHODS: In a total of 225 samples (100 normal and 125 abnormal samples), white blood cell (WBC) differentials and platelet (PLT) count estimation by EasyCell assistant were compared with the results by manual microscopic review and Pentra DX Nexus. The manual microscopic review was performed according to the Clinical and Laboratory Standards Institute guidelines (H20-A2). RESULTS: WBC differentials between pre-classification by EasyCell assistant and manual counting showed moderate correlations for neutrophils (r=0.58), lymphocytes (r=0.69), and eosinophils (r=0.51) in all samples. After user verification, they showed mostly high to very high correlations for neutrophils (r=0.74), lymphocytes (r=0.78), eosinophils (r=0.88), and other cells (r=0.91). PLT count by EasyCell assistant highly correlated with that by Pentra DX Nexus (r=0.82). CONCLUSIONS: The performance of EasyCell assistant for WBC differentials and PLT count seems to be acceptable even in abnormal samples with improvement after user verification. The EasyCell assistant, with its reliable performance on WBC differentials and PLT count, would help optimize the workflow of hematology laboratories with reduced workload of manual microscopic review.


Asunto(s)
Hematología , Humanos , Hematología/métodos , Leucocitos , Linfocitos , Recuento de Plaquetas , Laboratorios , Recuento de Leucocitos , Reproducibilidad de los Resultados
5.
Vox Sang ; 117(3): 354-360, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34319591

RESUMEN

BACKGROUND AND OBJECTIVES: Temperature indicators (TIs) are used to monitor the surface temperature of red blood cell (RBC) units. We compared the utility of a newly developed time-temperature indicator (TTI) prototype, Freshzone TTI (FZTTI) (Freshzone, Seoul, South Korea) and two US Food and Drug Administration-approved TIs, Safe-T-Vue 10 (STV10; Temptime Corporation, Morris Plains, NJ) and Blood Temp 10 (BT10; Timestrip UK Ltd, Cambridge, UK). MATERIALS AND METHODS: FZTTI, STV10 and BT10 were attached to 91 RBC units after issue (including eight units that were stored in refrigerators in the ward before transfusion). The time for colour change (CC) was monitored based on the 30-min rule. The CC of FZTTI indicated the total time elapsed since the temperature of RBC units exceeded 10°C, and the CC of STV10 and BT10 indicated that the temperature of RBC units exceeded 10°C. RESULTS: In 83 units, the median time for CC differed significantly between FZTTI and the TIs (51.4 min in FZTTI vs. 13.9 min in STV10 and 10.5 min in BT10, both at p < 0.001). In addition, 95.2% (n = 79) of FZTTI tags changed colour after 30 min of issue, whereas 96.4% (n = 80) of STV10 and 98.8% (n = 82) of BT10 changed colour within 30 min of issue. In the eight units stored in refrigerators, the time for CC between the TTI and TIs was significantly different. CONCLUSION: FZTTI outperformed the TIs, indicating that it is a feasible option for use in transfusion practice.


Asunto(s)
Conservación de la Sangre , Transfusión Sanguínea , Eritrocitos , Hospitales , Humanos , Temperatura
6.
Vox Sang ; 117(3): 399-407, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34318939

RESUMEN

BACKGROUND AND OBJECTIVES: VISION Max (Ortho Clinical Diagnostics, Raritan, NJ) measures anti-A/B isoagglutinin titres using automated column agglutination technology (CAT). We compared tube test (TT) and CAT of VISION Max comprehensively, including failure mode and effect analysis (FMEA), turnaround time (TAT) and cost, and suggested modified CAT (MCAT). MATERIALS AND METHODS: For 100 samples (each 25 for blood type A, B and O with anti-A and anti-B), anti-A/B isoagglutinin titres were measured by TT and CAT (1:2-1:1024 dilution), as well as by MCAT (with agglutination at 1:32 dilution, then perform additional testing from 1:64 to 1:1024). We assessed the agreement and correlation between TT and CAT and compared FMEA (risk priority number [RPN] score), TAT (h:min:sec) and cost (US dollar, US $) among TT, CAT and MCAT. RESULTS: TT and CAT showed overall substantial agreement (k = 0.73) and high correlation (ρ ≥ 0.75) except blood type O with anti-A (ρ = 0.68). Compared with TT, CAT showed lower RPN scores in FMEA and similar TAT and cost (FMEA, 33,700 vs. 184,300; TAT, 15:23:00 vs. 14:26:40; cost, 1377.4 vs. 1312.4, respectively). Regarding FMEA, TAT and cost, MCAT was superior to CAT or TT (43,810; 13:28:00; 899.2, respectively). CONCLUSION: This is the first multidimensional analysis on VISION Max CAT for measuring anti-A/B isoagglutinin titres. The results of anti-A/B isoagglutinin titres by CAT were comparable with those of TT. MCAT would be a safe, time-saving and cost-effective alternative to TT and CAT in high-volume blood bank laboratories.


Asunto(s)
Sistema del Grupo Sanguíneo ABO , Hemaglutininas , Aglutinación , Anticuerpos , Tecnología
7.
Medicina (Kaunas) ; 58(10)2022 Sep 21.
Artículo en Inglés | MEDLINE | ID: mdl-36295478

RESUMEN

Background: Krebs von den Lungen 6 (KL-6) is a novel biomarker for interstitial lung disease, and it reflects acute lung injury. We explored the usefulness of KL-6 to predict clinical outcomes in hospitalized coronavirus disease 2019 (COVID-19) patients. Methods: In a total of 48 hospitalized COVID-19 patients, KL-6 levels were measured using the HISCL KL-6 assay (Sysmex, Kobe, Japan) with the HISCL 5000 automated analyzer (Sysmex). Clinical outcomes (intensive care unit [ICU] admission, ventilator use, extracorporeal membrane oxygenation [ECMO] use, and 30-day mortality) were analyzed according to KL-6 percentiles. Age, initial KL-6 level, Charlson comorbidity index (CCI), and critical disease were compared using the receiver operating characteristic (ROC) curve and Kaplan-Meier methods for clinical outcomes. Results: KL-6 quartiles were associated with ICU admission, ventilator use, and ECMO use (all p < 0.05), except 30-day mortality (p = 0.187). On ROC curve analysis, initial KL-6 level predicted ICU admission, ventilator use, and ECMO use significantly better than age, CCI, and critical disease (all p < 0.05); age, initial KL-6 level, CCI, and critical disease predicted 30-day mortality comparably. On Kaplan−Meier survival analysis, hazard ratios (95% confidence interval) were 4.8 (1.2−19.3) for age, 4.7 (1.1−21.6) for initial KL-6 level, 3.9 (0.9−16.2) for CCI, and 2.1 (0.5−10.3) for critical disease. Conclusions: This study demonstrated that KL-6 could be a useful biomarker to predict clinical outcomes in hospitalized COVID-19 patients. KL-6 may contribute to identifying COVID-19 patients requiring critical care, including ICU admission and ventilator and/or ECMO use.


Asunto(s)
COVID-19 , Enfermedades Pulmonares Intersticiales , Humanos , Preescolar , COVID-19/terapia , Curva ROC , Biomarcadores , Japón/epidemiología
8.
Clin Chem Lab Med ; 59(6): 1099-1106, 2021 05 26.
Artículo en Inglés | MEDLINE | ID: mdl-33470955

RESUMEN

OBJECTIVES: Vision Pro (West Medica, Perchtoldsdorf, Austria) is a recently developed digital morphology analyzer. We evaluated the performance of Vision Pro on white blood cell (WBC) differentials. METHODS: In a total of 200 peripheral blood smear samples (100 normal and 100 abnormal samples), WBC preclassification and reclassification by Vision Pro were evaluated and compared with manual WBC count, according to the Clinical and Laboratory Standards Institute guidelines (H20-A2). RESULTS: The overall sensitivity was high for normal WBCs and nRBCs (80.1-98.0%). The overall specificity and overall efficiency were high for all cell classes (98.1-100.0% and 97.7-99.9%, respectively). The absolute values of mean differences between Vision Pro and manual count ranged from 0.01 to 1.31. In leukopenic samples, those values ranged from 0.09 to 2.01. For normal WBCs, Vision Pro preclassification and manual count showed moderate or high correlations (r=0.52-0.88) except for basophils (r=0.34); after reclassification, the correlation between Vision Pro and manual count was improved (r=0.36-0.90). CONCLUSIONS: This is the first study that evaluated the performance of Vision Pro on WBC differentials. Vision Pro showed reliable analytical performance on WBC differentials with improvement after reclassification. Vision Pro could help improve laboratory workflow.


Asunto(s)
Leucocitos , Proyectos de Investigación , Recuento de Células Sanguíneas , Recuento de Leucocitos , Estándares de Referencia
9.
Am J Kidney Dis ; 76(6): 826-841.e1, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32679151

RESUMEN

RATIONALE & OBJECTIVE: The usefulness of measures of neutrophil gelatinase-associated lipocalin (NGAL) in urine or plasma obtained on clinical laboratory platforms for predicting acute kidney injury (AKI) and AKI requiring dialysis (AKI-D) has not been fully evaluated. We sought to quantitatively summarize published data to evaluate the value of urinary and plasma NGAL for kidney risk prediction. STUDY DESIGN: Literature-based meta-analysis and individual-study-data meta-analysis of diagnostic studies following PRISMA-IPD guidelines. SETTING & STUDY POPULATIONS: Studies of adults investigating AKI, severe AKI, and AKI-D in the setting of cardiac surgery, intensive care, or emergency department care using either urinary or plasma NGAL measured on clinical laboratory platforms. SELECTION CRITERIA FOR STUDIES: PubMed, Web of Science, Cochrane Library, Scopus, and congress abstracts ever published through February 2020 reporting diagnostic test studies of NGAL measured on clinical laboratory platforms to predict AKI. DATA EXTRACTION: Individual-study-data meta-analysis was accomplished by giving authors data specifications tailored to their studies and requesting standardized patient-level data analysis. ANALYTICAL APPROACH: Individual-study-data meta-analysis used a bivariate time-to-event model for interval-censored data from which discriminative ability (AUC) was characterized. NGAL cutoff concentrations at 95% sensitivity, 95% specificity, and optimal sensitivity and specificity were also estimated. Models incorporated as confounders the clinical setting and use versus nonuse of urine output as a criterion for AKI. A literature-based meta-analysis was also performed for all published studies including those for which the authors were unable to provide individual-study data analyses. RESULTS: We included 52 observational studies involving 13,040 patients. We analyzed 30 data sets for the individual-study-data meta-analysis. For AKI, severe AKI, and AKI-D, numbers of events were 837, 304, and 103 for analyses of urinary NGAL, respectively; these values were 705, 271, and 178 for analyses of plasma NGAL. Discriminative performance was similar in both meta-analyses. Individual-study-data meta-analysis AUCs for urinary NGAL were 0.75 (95% CI, 0.73-0.76) and 0.80 (95% CI, 0.79-0.81) for severe AKI and AKI-D, respectively; for plasma NGAL, the corresponding AUCs were 0.80 (95% CI, 0.79-0.81) and 0.86 (95% CI, 0.84-0.86). Cutoff concentrations at 95% specificity for urinary NGAL were>580ng/mL with 27% sensitivity for severe AKI and>589ng/mL with 24% sensitivity for AKI-D. Corresponding cutoffs for plasma NGAL were>364ng/mL with 44% sensitivity and>546ng/mL with 26% sensitivity, respectively. LIMITATIONS: Practice variability in initiation of dialysis. Imperfect harmonization of data across studies. CONCLUSIONS: Urinary and plasma NGAL concentrations may identify patients at high risk for AKI in clinical research and practice. The cutoff concentrations reported in this study require prospective evaluation.


Asunto(s)
Lesión Renal Aguda/diagnóstico , Lipocalina 2/sangre , Diálisis Renal , Lesión Renal Aguda/metabolismo , Lesión Renal Aguda/terapia , Biomarcadores/sangre , Biomarcadores/orina , Humanos , Valor Predictivo de las Pruebas
10.
J Clin Lab Anal ; 34(6): e23242, 2020 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32154615

RESUMEN

BACKGROUND: Although plasma free hemoglobin (fHb) test is important for assessing intravascular hemolysis, it is still dependent on the gold standard Harboe method using manual and labor-intensive spectrometric measurements at the wavelength of 380-415-450 nm. We established an automated fHb assay using a routine chemistry autoanalyzer that can be tuned to a wavelength of 380-416-450 nm. METHODS: The linearity, precision, accuracy, correlation, and sample carryover of fHb measurement using TBA200FRneo method and manual Harboe method were evaluated, respectively. fHb values measured by manual Harboe method were compared with those measured by our new automated TBA200FRneo method. RESULTS: fHb measurements were linear in the range of 0.05~38.75 µmol/L by TBA200FRneo and 0.05~9.69 µmol/L by manual Harboe method. Imprecision analysis (%CV) revealed 0.9~2.8% for TBA200FRneo method and 5.3~13.6% for the manual Harboe method. Comparison analysis showed 0.9986 of correlation coefficient (TBA200FRneo = 0.970 × Harboe + 0.12). In analytical accuracy analysis, the manual Harboe method revealed about 4 times higher average total error % (12.2%) than the TBA200FRneo automated method (2.8%). The sample carryover was -0.0016% in TBA200FRneo method and 0.0038% in Harboe method. CONCLUSIONS: In the measurement of fHb, the automated TBA200FRneo method showed better performance than the conventional Harboe method. It is expected that the automated fHb assay using the routine chemistry analyzer can replace the gold standard Harboe method which is labor-intensive and need an independent spectrophotometry equipment.


Asunto(s)
Análisis Químico de la Sangre/métodos , Hemoglobinas/análisis , Espectrofotometría/métodos , Automatización de Laboratorios , Análisis Químico de la Sangre/instrumentación , Humanos , Espectrofotometría/instrumentación
11.
Vox Sang ; 114(5): 487-494, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31056755

RESUMEN

BACKGROUND AND OBJECTIVES: The 30-min rule has been used to maintain a core temperature (CT) of red-blood-cell (RBC) units below 10°C during transportation. We evaluated the utility of temperature-sensitive indicators (TIs) to monitor the surface temperature (ST) of RBC units and to explore whether TIs can help with compliance with the 30-min rule by extrapolating or correlating temperature change with time. MATERIALS AND METHODS: Two US FDA-approved TIs, Safe-T-Vue 10 (STV10; Temptime Corporation, Morris Plains, NJ, USA) and Timestrip Blood Temp 10 (BT10; Timestrip UK Ltd, Cambridge, UK), were attached to 50 RBC units. After issue, their colour change indicating 10°C was monitored, and temperature excursions were measured by standard reading. In additional 18 RBC units, both ST and CT were monitored simultaneously. RESULTS: In 50 RBC units, 94% of STV10 and 100% of BT10 showed colour change indicating 10°C within 30 min; 4% of STV10 and 18% of BT10 showed it during transportation. The time for colour change indicating 10°C differed significantly between STV10 and BT10 (19·0 vs. 5·6 min, P < 0·001). In additional 18 RBC units, 83·3% of STV10, 100% of BT10 and 88·9% of CT reached 10°C within 30 min, and the time for colour change indicating 10°C was 24·4 min in STV10, 14·6 min in BT 10 and 24·2 min in CT (P < 0·001). CONCLUSION: In two TIs, the time for colour change indicating 10°C varied considerably. To enhance the utility of TIs, further improvement and standardization would be needed.


Asunto(s)
Conservación de la Sangre/normas , Eritrocitos , Temperatura , Conservación de la Sangre/métodos , Humanos , Indicadores y Reactivos
12.
Infection ; 46(1): 113-117, 2018 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-29218569

RESUMEN

PURPOSE: This study aimed to evaluate the clinical significance of toxin positivity and toxin gene load, and the relation between them in the broad spectrum of Clostridium difficile infection (CDI) including colonization, significant diarrhea, and severe disease. METHODS: We included 2671 fecal samples submitted for CDI diagnosis and 180 samples from healthy individuals. The clinical spectrum was categorized as category I (toxigenic C. difficile positive without clinical CDI criteria), category II (mild CDI), and category III (severe CDI). Clinical parameters were compared based on toxin EIA and tcdB C t values. C t values of tcdB PCR for predicting toxin EIA positivity were assessed using receiver-operating characteristic (ROC) curves. RESULTS: The median C t values of tcdB PCR and toxin positivity were not significantly correlated with clinical spectrum of CDI (27.5, 28.2, and 26.1 for tcdB C t and 55.0, 56.6, and 60.9% for toxin EIA positivity in category I, II, and III, respectively, P > 0.05). There were significant differences in the tcdB C t values between toxin EIA-positive and -negative groups (P < 0.001). Optimal cutoff for the tcdB C t value for estimating toxin EIA positivity was 26.3 with 79.3% sensitivity and 83.6% specificity with good area under the curves (AUC, 0.848). CONCLUSIONS: The C t values successfully predicted toxin EIA positivity and could be used as a surrogate for toxin EIA positivity in the diagnostic algorithm and routine analysis. Further studies are needed to validate the clinical significance of tcdB PCR C t value in toxigenic C. difficile colonization and infection.


Asunto(s)
Proteínas Bacterianas/genética , Toxinas Bacterianas/genética , Clostridioides difficile/fisiología , Infecciones por Clostridium/microbiología , Diarrea/microbiología , Carga Genética , Adulto , Anciano , Anciano de 80 o más Años , Proteínas Bacterianas/metabolismo , Toxinas Bacterianas/metabolismo , Clostridioides difficile/genética , Heces/microbiología , Femenino , Humanos , Masculino , Persona de Mediana Edad
13.
Clin Chem Lab Med ; 56(7): 1133-1139, 2018 06 27.
Artículo en Inglés | MEDLINE | ID: mdl-29455185

RESUMEN

BACKGROUND: Hepatitis B virus (HBV) nucleic acid amplification testing (NAAT) is important for the diagnosis and management of HBV infection. We evaluated the analytical performance of the cobas HBV NAAT (Roche Diagnostics GmbH, Mannheim, Germany) on the cobas 4800 System in comparison with COBAS AmpliPrep/COBAS TaqMan HBV Test (CAP/CTM HBV). METHODS: Precision was evaluated using three levels of cobas HBV/HCV/HIV-1 Control Kit, and linearity was evaluated across the anticipated measuring range (10.0-1.0×109 IU/mL) at seven levels using clinical samples. Detection capability, including limit of blank (LOB), limit of detection (LOD) and limit of quantitation (LOQ), was verified using the 4th WHO International Standard for HBV DNA for NAT (NIBSC code: 10/266). Correlation between the two systems was compared using 205 clinical samples (102 sera and 103 EDTA plasma). RESULTS: Repeatability and total imprecision (coefficient of variation) ranged from 0.5% to 3.8% and from 0.5% to 3.5%, respectively. Linearity (coefficient of determination, R2) was 0.999. LOB, LOD and LOQ were all acceptable within the observed proportion rate (85%). Correlation was very high between the two systems in both serum and plasma samples (correlation coefficient [r]=0.995). CONCLUSIONS: The new cobas HBV real-time PCR assay on the cobas 4800 System showed reliable analytical performances.


Asunto(s)
ADN Viral/sangre , Virus de la Hepatitis B/genética , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Carga Viral/métodos , Humanos , Límite de Detección
15.
J Gastroenterol Hepatol ; 33(7): 1370-1378, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29232004

RESUMEN

BACKGROUND AND AIM: Naturally occurring hepatitis B virus variants carrying a deletion in the preS1 start codon region may evolve during long-lasting virus-host interactions in chronic hepatitis B (CHB). The aim of this study was to determine the immune phase-specific prevalent patterns of preS1 start codon deletion variants and related factors during the natural course of CHB. METHODS: A total of 399 CHB patients were enrolled. Genotypic analysis of three different preS1 start codon deletion variants (classified by deletion size: 15-base pair [bp], 18-bp, and 21-bp deletion variants) was performed. RESULTS: PreS1 start codon deletion variants were detected in 155 of 399 patients (38.8%). The predominant variant was a 15-bp deletion in the immune-tolerance phase (18/50, 36%) and an 18-bp deletion in the immune-clearance phase (69/183, 37.7%). A 21-bp deletion was the predominant variant in the low replicative phase (3/25, 12.0%) and reactivated hepatitis Be antigen (HBeAg)-negative phase (22/141, 15.6%). The 15-bp and 18-bp deletion variants were more frequently found in HBeAg-positive patients (P < 0.010 and P < 0.001, respectively), whereas the 21-bp deletion variant was more frequently found in HBeAg-negative patients (P < 0.001). On multiple logistic regression analyses, the 21-bp deletion variant was independently associated with liver cirrhosis (P = 0.006), and the 15-bp deletion variant was significantly related to an incomplete response to antiviral agents (P = 0.012). CONCLUSIONS: The predominant type of preS1 start codon deletion variants changes according to the immune phases of CHB infection, and each variant type is associated with different clinical parameters. PreS1 start codon deletion variants might interact with the host immune response differently according to their variant types.


Asunto(s)
Codón/genética , Eliminación de Gen , Variación Genética , Antígenos de Superficie de la Hepatitis B/genética , Virus de la Hepatitis B/genética , Hepatitis B Crónica/virología , Interacciones Huésped-Patógeno/genética , Precursores de Proteínas/genética , Adulto , Antivirales , Femenino , Técnicas de Genotipaje , Hepatitis B Crónica/inmunología , Humanos , Cirrosis Hepática/genética , Cirrosis Hepática/virología , Modelos Logísticos , Masculino , Persona de Mediana Edad
16.
Scand J Clin Lab Invest ; 78(6): 477-482, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30073867

RESUMEN

Anti-cyclic citrullinated peptide antibodies (anti-CCPs) are important diagnostic markers for rheumatoid arthritis (RA). We evaluated the analytical and clinical performance of the QUANTA Flash CCP3 (INOVA Diagnostics, USA), a fully automated third-generation anti-CCP assay, in comparison with three second-generation anti-CCP (CCP2) assays. A total of 300 sera (67 from RA patients, 64 from other rheumatic diseases, 43 from osteoarthritis [OA], and 126 from other conditions) were tested with QUANTA Flash CCP3, Kallestad Anti-CCP II (Bio-Rad, USA), Elecsys Anti-CCP (Roche Diagnostics GmbH, Germany), and ARCHITECT Anti-CCP (Abbott Diagnostics, USA). Within-run and total imprecision (% coefficient of variation) of the QUANTA Flash CCP3 were <6%, and its linearity was acceptable over the claimed range (4.0-2,749.7 chemiluminescent units). The frequency of anti-CCP was similar between QUANTA Flash CCP3 and the other CCP2 assays in the RA (67.2% vs. 62.7-70.1%), other rheumatic diseases (7.8% vs. 6.3%), and OA (2.3% vs. 0-2.3%) groups. The concordance rate between QUANTA Flash CCP3 and the other assays ranged from 96.3% to 97.7% (kappa from 0.87 to 0.92). For the diagnosis of RA, the sensitivity/specificity was 67.2%/95.7%, 62.7%/98.3%, 70.2%/96.6%, and 67.2%/97.9%, and the areas under the receiver operating characteristic curves were 0.851, 0.791, 0.853, and 0.867 for QUANTA Flash CCP3, Kallestad, Elecsys, and ARCHITECT assays, respectively. The performance of the QUANTA Flash CCP3 was satisfactory and comparable to that of the three CCP2 assays. This fully automated assay would be a practical and reasonable option in clinical laboratories.


Asunto(s)
Anticuerpos Antiproteína Citrulinada/sangre , Artritis Reumatoide/diagnóstico , Automatización de Laboratorios/normas , Inmunoensayo/normas , Osteoartritis/diagnóstico , Adulto , Anciano , Artritis Reumatoide/sangre , Artritis Reumatoide/inmunología , Artritis Reumatoide/patología , Biomarcadores/sangre , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Osteoartritis/sangre , Osteoartritis/inmunología , Osteoartritis/patología , Curva ROC
18.
Clin Chem Lab Med ; 56(1): 94-102, 2017 Nov 27.
Artículo en Inglés | MEDLINE | ID: mdl-28672770

RESUMEN

BACKGROUND: The Sysmex DI-60 system (DI-60, Sysmex, Kobe, Japan) is a new automated digital cell imaging analyzer. We explored the performance of DI-60 in comparison with Sysmex XN analyzer (XN, Sysmex) and manual count. METHODS: In a total of 276 samples (176 abnormal and 100 normal samples), white blood cell (WBC) differentials, red blood cell (RBC) classification and platelet (PLT) estimation by DI-60 were compared with the results by XN and/or manual count. RBC morphology between pre-classification and verification was compared according to the ICSH grading criteria. The manual count was performed according to the Clinical and Laboratory Standards Institute guidelines (H20-A2). RESULTS: The overall concordance between DI-60 and manual count for WBCs was 86.0%. The agreement between DI-60 pre-classification and verification was excellent (weighted κ=0.963) for WBC five-part differentials. The correlation with manual count was very strong for neutrophils (r=0.955), lymphocytes (r=0.871), immature granulocytes (r=0.820), and blasts (r=0.879). RBC grading showed notable differences between DI-60 and manual counting on the basis of the ICSH grading criteria. Platelet count by DI-60 highly correlated with that by XN (r=0.945). However, DI-60 underestimated platelet counts in samples with marked thrombocytosis. CONCLUSIONS: The performance of DI-60 for WBC differential, RBC classification, and platelet estimation seems to be acceptable even in abnormal samples with improvement after verification. DI-60 would help optimize the workflow in hematology laboratory with reduced manual workload.


Asunto(s)
Automatización , Pruebas Hematológicas , Recuento de Células Sanguíneas , Eritrocitos/citología , Pruebas Hematológicas/instrumentación , Humanos , Leucocitos/citología , Linfocitos/citología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA