Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Banco de datos
Tipo del documento
Asunto de la revista
Intervalo de año de publicación
1.
Small ; : e2404251, 2024 Aug 23.
Artículo en Inglés | MEDLINE | ID: mdl-39175372

RESUMEN

Peripheral vascular interventions (PVIs) offer several benefits to patients with lower extremity arterial diseases, including reduced pain, simpler anesthesia, and shorter recovery time, compared to open surgery. However, to monitor the endovascular tools inside the body, PVIs are conducted under X-ray fluoroscopy, which poses serious long-term health risks to physicians and patients. Shortwave infrared (SWIR) imaging of quantum dots (QDs) has shown great potential in bioimaging due to the non-ionizing penetration of SWIR light through tissues. In this paper, a QD-based magnetic guidewire and its system is introduced that allows X-ray-free detection under SWIR imaging and precise steering via magnetic manipulation. The QD magnetic guidewire contains a flexible silicone tube encapsulating a QD polydimethylsiloxane (PDMS) composite, where HgCdSe/HgS/CdS/CdZnS/ZnS/SiO2 core/multi-shell QDs are dispersed in the PDMS matrix for SWIR imaging upon near-infrared excitation, as well as a permanent magnet for magnetic steering. The SWIR penetration of the QD magnetic guidewire is investigated within an artificial tissue model (1% Intralipid) and explore the potential for non-fluoroscopic PVIs within a vascular phantom model. The QD magnetic guidewire is biocompatible in its entirety, with excellent resistance to photobleaching and chemical alteration, which is a promising sign for its future clinical implementation.

2.
Mater Horiz ; 9(12): 3031-3038, 2022 11 28.
Artículo en Inglés | MEDLINE | ID: mdl-36129054

RESUMEN

Cell therapy refers to a treatment that involves the delivery of cells or cellular material by means of injection, grafting, or implantation in order to replace damaged tissue and restore its function, or to aid the body in fighting disease. However, limitations include poor targeting delivery and low therapeutic efficacy due to low cell survival. Hence, novel approaches are required to increase cell delivery efficiency and enhance therapeutic efficacy via selective cell differentiation at target areas. Here, we present a stamping magnetoelectric microscale biorobot (SMMB) consisting of neuron-like cell spheroids loaded with magnetoelectric nanoparticles. The SMMB enables not only effective targeted delivery of cells to multiple target areas (via minimally invasive stamping employing magnetic actuation) but also facilitates selective neuronal differentiation via magnetoelectric (ME) stimulation. This ensures rapid colonization and enhances efficacy. SMMBs were fabricated using SH-SY5Y cells. Magnetoelectric nanoparticles for ME stimulation responded to an alternating magnetic field that ensured targeted cell differentiation. Multi-target cell therapy facilitated the targeted delivery and selective differentiation of SH-SY5Y cells to multiple regions using a single SMMB with rotating and alternating magnetic fields for delivery and ME stimulation. This promising tool may overcome the limitations of existing cell therapy for neurodegenerative diseases.


Asunto(s)
Neuroblastoma , Humanos , Diferenciación Celular , Neuronas , Campos Magnéticos , Tratamiento Basado en Trasplante de Células y Tejidos
3.
Adv Healthc Mater ; 11(11): e2102529, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35137568

RESUMEN

Robotic magnetic manipulation systems offer a wide range of potential benefits in medical fields, such as precise and selective manipulation of magnetically responsive instruments in difficult-to-reach vessels and tissues. However, more preclinical/clinical studies are necessary before robotic magnetic interventional systems can be widely adopted. In this study, a clinically translatable, electromagnetically controllable microrobotic interventional system (ECMIS) that assists a physician in remotely manipulating and controlling microdiameter guidewires in real time, is reported. The ECMIS comprises a microrobotic guidewire capable of active magnetic steering under low-strength magnetic fields, a human-scale electromagnetic actuation (EMA) system, a biplane X-ray imaging system, and a remote guidewire/catheter advancer unit. The proposed ECMIS demonstrates targeted real-time cardiovascular interventions in vascular phantoms through precise and rapid control of the microrobotic guidewire under EMA. Further, the potential clinical effectiveness of the ECMIS for real-time cardiovascular interventions is investigated through preclinical studies in coronary, iliac, and renal arteries of swine models in vivo, where the magnetic steering of the microrobotic guidewire and control of other ECMIS modules are teleoperated by operators in a separate control booth with X-ray shielding. The proposed ECMIS can help medical physicians optimally manipulate interventional devices such as guidewires under minimal radiation exposure.


Asunto(s)
Campos Magnéticos , Magnetismo , Animales , Diseño de Equipo , Fantasmas de Imagen , Porcinos
4.
Sci Robot ; 6(52)2021 03 24.
Artículo en Inglés | MEDLINE | ID: mdl-34043554

RESUMEN

Neutrophil-based microrobots accomplish the mission of crossing the blood-brain barrier for targeted drug delivery.


Asunto(s)
Preparaciones Farmacéuticas , Transporte Biológico , Barrera Hematoencefálica , Sistemas de Liberación de Medicamentos
5.
Adv Healthc Mater ; 10(6): e2001596, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33331143

RESUMEN

Therapeutic agents, such as drugs and cells, play an essential role in virtually every treatment of injury, illness, or disease. However, the conventional practices of drug delivery often result in undesirable side effects caused by drug overdose and off-target delivery. In the case of cell delivery, the survival rate of the transplanted cells is extremely low and difficulties with the administration route of cells remain a problem. Recently, magnetically actuated microrobots have started offering unique opportunities in targeted therapeutic delivery due to their tiny size and ability to access hard-to-reach lesions in a minimally invasive manner; considerable advances in this regard have been made over the past decade. Here, recent progress in magnetically actuated microrobots, developed for targeted drug/cell delivery, is presented, with a focus on their design features and mechanisms for controlled therapeutic release. Additionally, the practical challenges faced by the microrobots, and future research directions toward the swift bench-to-bedside translation of the microrobots are addressed.


Asunto(s)
Sistemas de Liberación de Medicamentos , Preparaciones Farmacéuticas
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA