Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Synchrotron Radiat ; 17(6): 813-6, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-20975230

RESUMEN

The understanding of and in situ observation of the transport and distribution of water in carbon-paper gas diffusion layers (GDLs) using non-destructive imaging techniques is critical for achieving high performance in polymer electrolyte fuel cells (PEFCs). To investigate the behavior of water in GDLs of PEFCs, phase-contrast X-ray imaging via X-ray interferometric imaging (XII) and diffraction-enhanced imaging (DEI) were performed using 35 keV X-rays. The XII technique is useful for the radiographic imaging of GDLs and in situ observations of water evolution processes in operating PEFCs. DEI provides a way for tomographic imaging of GDLs in PEFCs. Because high-energy X-rays are applicable to the imaging of both carbon papers and heavy materials, which make up PEFCs, phase-contrast X-ray imaging techniques have proven to be valuable for investigation of GDLs.

2.
Eur Surg Res ; 42(4): 249-57, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19346745

RESUMEN

BACKGROUND/AIMS: Many studies report the role of vascular endothelial growth factor (VEGF) in wound healing, but few describe local VEGF administration to the digestive tract. Leakage from colonic anastomoses, including those due to ischemia, represents a major complication causing increased mortality and morbidity. Angiogenesis is crucial to anastomotic healing and restoration of blood supply, and VEGF is a potent angiogenic factor showing improved healing in various models of reconstruction and anastomosis. Here, we examine the effects of local VEGF-A(165) administration on postoperative rabbit colon anastomosis. METHODS: Two colotomies per animal were made in the sinistral colon on opposite sides of the mesentery. Randomly assigned VEGF (10 microg/0.1 ml) or saline (0.1 ml) was injected into the muscularis propria on both sides of each colonic anastomosis before closing the access laparotomy using single-layer sutures. On postoperative days 3, 4 and 7, the bursting pressure of partially healed anastomoses was measured. On postoperative day 4, anastomotic tissues were examined for the following: hydroxyproline; histopathologically for inflammatory infiltrate and tissue organization and immunohistochemically for capillary proliferation and density; vessel density of midzone collaterals around anastomoses by microangiography. RESULTS: Compared to saline, VEGF administration significantly improved bursting pressure (p = 0.014, paired t test) and increased hydroxyproline (p = 0.027, paired t test) on postoperative day 4. Inflammatory cell infiltration and fibroblast proliferation were prominent, and submucosal capillary vascular counts were significantly higher for VEGF. CONCLUSIONS: Administration of VEGF to colonic anastomosis accelerates wound healing and strengthens the anastomosis by increased angiogenesis.


Asunto(s)
Colon/cirugía , Factor A de Crecimiento Endotelial Vascular/administración & dosificación , Cicatrización de Heridas/efectos de los fármacos , Anastomosis Quirúrgica , Angiografía , Animales , Colon/irrigación sanguínea , Colon/metabolismo , Colon/patología , Hidroxiprolina/metabolismo , Masculino , Neovascularización Fisiológica/efectos de los fármacos , Presión , Conejos
3.
Neuroscience ; 138(4): 1205-13, 2006.
Artículo en Inglés | MEDLINE | ID: mdl-16460878

RESUMEN

Densely aggregated beta-amyloid peptides are believed to play a key role in the pathogenesis of Alzheimer's disease. Amyloid plaques are a potential target for molecular imaging to determine the clinical status of Alzheimer's disease. Phase-contrast X-ray imaging combined with computed tomography is a promising technique that can be used to visualize the physical density of structures in biological tissues non-invasively, and without the use of imaging agents. Using brain tissue isolated from a mouse model of Alzheimer's disease, we show that beta-amyloid 40-positive/beta-amyloid 42-positive amyloid plaques, but not beta-amyloid 40-negative/beta-amyloid 42-positive amyloid plaques, exist as high-density aggregates that can be specifically detected by phase-contrast X-ray computed tomography. The phase-contrast X-ray computed tomography detected beta-amyloid 40-positive/beta-amyloid 42-positive amyloid plaques in three-dimensions with an extremely high sensitivity comparable to that of histological analysis, and also enabled the load of amyloid plaques to be quantified. Furthermore, the use of phase-contrast X-ray computed tomography reveals that the physical density of beta-amyloid 40-positive/beta-amyloid 42-positive amyloid plaques increases with age, and that the large volume, high-density, amyloid plaques that are specifically observed in aged Alzheimer's disease mice are closely associated with neuritic dystrophy. These results demonstrate that phase-contrast X-ray computed tomography is a highly sensitive imaging technique for analyzing dense-cored amyloid plaques in postmortem samples, and is beneficial in elucidating amyloid pathophysiology in Alzheimer's disease.


Asunto(s)
Enfermedad de Alzheimer/diagnóstico por imagen , Corteza Cerebral/diagnóstico por imagen , Corteza Cerebral/patología , Placa Amiloide/diagnóstico por imagen , Placa Amiloide/patología , Tomografía Computarizada por Rayos X/métodos , Envejecimiento/patología , Enfermedad de Alzheimer/fisiopatología , Péptidos beta-Amiloides/metabolismo , Animales , Corteza Cerebral/metabolismo , Modelos Animales de Enfermedad , Femenino , Ratones , Ratones Transgénicos , Microscopía de Contraste de Fase/métodos , Neuritas/metabolismo , Neuritas/patología , Fragmentos de Péptidos/metabolismo , Placa Amiloide/metabolismo , Valor Predictivo de las Pruebas
4.
J Control Release ; 220(Pt A): 44-50, 2015 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-26478014

RESUMEN

Considerable efforts have been directed towards discovering and developing delivery vehicles for RNA therapeutics. While most studies emphasize the efficacy and safety of these delivery vehicles, few reports conduct a comprehensive assessment of their storage stability, a critical property for practical applications. Here, we report a potent and safe lipid nanoparticle with long-term storage stability. Through chemical synthesis and screening of cationic lipids, a formulation has been identified that enables potent knockdown of hepatocyte proteins in mice upon intravenous administration (siRNA ED50 ~0.02 mg/kg). Toxicity studies revealed that a dose of 2mg/kg was well tolerated in rats, the most sensitive rodent model. We identified that a cyclic chemical structure in cationic lipids improved particle stability. The nanoparticles showed over 1.5 year storage stability as a liquid, with over 90% siRNA encapsulation without any changes in particle size. This novel delivery material has promising potential as a drug product that could bring RNA therapeutics to the treatment of liver-related disorders.


Asunto(s)
Silenciador del Gen , Lípidos/química , Nanopartículas/química , ARN Interferente Pequeño/química , Animales , Masculino , Ratones , Ratones Endogámicos BALB C , Ratones Endogámicos C57BL , Factores de Tiempo
5.
J Nucl Med ; 20(8): 827-32, 1979 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-94354

RESUMEN

We have investigated the thyroid uptake of Tl-201 in 37 patients with various types of goiter, and in six with normal thyroids. Significant thallium uptake was found in all cases in which there was thyroid enlargement, including Graves' disease, toxic thyroid nodule, primary hypothyroidism, simple goiter, Hashimoto's disease, thyroid carcinoma, and thyroid adenoma. If goiter was absent, however, there was no demonstrable uptake--e.g., in secondary hypothyroidism, subacute thyroiditis, and the normal controls. Thallium uptake did not correlate with thyroid function tests such as BMR, T3-RU, T3, T4, TSH, antithyroid antibodies, or the 24-hr I-131 uptake. In 23 patients with diffuse goiter, on the other hand, maximum Tl-201 uptake correlated well with thyroid weight: r = 0.836 (p less than 0.001); y = 0.02 x + 0.06.


Asunto(s)
Radioisótopos , Talio , Enfermedades de la Tiroides/diagnóstico por imagen , Adenoma/diagnóstico por imagen , Antitiroideos/farmacología , Medios de Contraste/farmacología , Bocio/diagnóstico por imagen , Bocio Nodular/diagnóstico por imagen , Enfermedad de Graves/diagnóstico por imagen , Humanos , Hipotiroidismo/diagnóstico por imagen , Yodipamida/farmacología , Metimazol/farmacología , Cintigrafía , Síndrome , Tiroides (USP)/farmacología , Pruebas de Función de la Tiroides , Neoplasias de la Tiroides/diagnóstico por imagen , Tiroiditis/diagnóstico por imagen , Tiroiditis Autoinmune/diagnóstico por imagen , Tirotropina/farmacología
6.
J Nucl Med ; 19(2): 195-6, 1978 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-627899

RESUMEN

Before surgery, thallium-201 chloride detected a supraclavicular metastasis from a mixed follicular and papillary adenocarcinoma of the thyroid.


Asunto(s)
Adenocarcinoma/diagnóstico por imagen , Metástasis Linfática/diagnóstico por imagen , Radioisótopos , Talio , Neoplasias de la Tiroides/diagnóstico por imagen , Adulto , Femenino , Humanos , Cintigrafía
7.
J Nucl Med ; 18(12): 1199-201, 1977 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-606744

RESUMEN

Marked thyroid uptake of thallium-201 was observed in four patients with goiter, namely one case each of hyperthyroidism, primary hypothyroidism due to chronic thyroiditis, chronic thyroiditis in the mild hypothyroid state, and nontoxic nodular goiter.


Asunto(s)
Bocio/diagnóstico por imagen , Radioisótopos , Talio , Glándula Tiroides/diagnóstico por imagen , Adulto , Anciano , Femenino , Bocio/metabolismo , Humanos , Masculino , Persona de Mediana Edad , Cintigrafía , Talio/metabolismo , Glándula Tiroides/metabolismo
8.
AJNR Am J Neuroradiol ; 20(5): 801-6, 1999 May.
Artículo en Inglés | MEDLINE | ID: mdl-10369349

RESUMEN

BACKGROUND AND PURPOSE: Conventional X-ray angiography lacks the sensitivity and spatial resolution needed to detect small amounts of iodinated contrast material and to quantitate diameters of the small vessels in the brain. The purpose of this study was to ascertain whether digitized synchrotron radiation microangiography, with the use of a high-definition TV camera system, can accurately show small cerebral vessels. METHODS: Six anesthetized dogs were exposed to monochromatic synchrotron radiation with an energy level of 33.3 keV optimized for iodine detection while iodinated contrast material was injected into the brachiocephalic and vertebral arteries. The images were detected with a high-definition TV camera system with a spatial resolution of 30 microm. In all, 26 cerebral angiograms of the circle of Willis with its branches were obtained, and the images were digitized at a workstation. RESULTS: The small branches of the circle of Willis were clearly visible on all images. Vasodilatation of the circle of Willis and its large and small branches induced by CO2 inhalation was quantitatively confirmed on the images: for example, the diameter of one small branch was increased from 0.24 +/- 0.04 mm to 0.38 +/- 0.12 mm. Temporal subtraction improved the image quality. CONCLUSION: The synchrotron radiation angiographic system is useful for visualizing large and small vessels deep in the brain as well as for quantitating their diameters.


Asunto(s)
Angiografía de Substracción Digital , Círculo Arterial Cerebral/diagnóstico por imagen , Sincrotrones , Angiografía de Substracción Digital/métodos , Animales , Angiografía Cerebral , Medios de Contraste , Perros , Procesamiento de Imagen Asistido por Computador , Microrradiografía
9.
J Biomed Opt ; 6(3): 371-7, 2001 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-11516330

RESUMEN

A synchrotron light source dedicated to medical applications has been designed at National Institute of Radiological Sciences. The storage ring, with circumference of 80 m, is designed for acceleration of 2.3 GeV and a stored current of 420 mA. It is equipped with two multipole wigglers to produce sufficient photon flux in a hard x-ray region required for medical applications. The purposes of the synchrotron light source are clinical performance of medical diagnoses clinically and research and development relating with medical applications. One of the most interesting applications for us is dual-energy x-ray computed tomography (CT). It gives the information about electron density of human tissue. The information plays an important role in advancing heavy-ion radiotherapy of cancers. Electron density can be derived from attenuation coefficients measured by different energy x rays. In this paper, a practical method of the dual-energy x-ray CT with synchrotron radiation is proposed with the theoretical consideration. The primitive experiment using monochromatic x rays emitted from radioisotopes proved the procedure of analysis mentioned here effective to derive electron densities from linear attenuation coefficients for two x rays of a different energy. The beamline dedicated to dual-energy x-ray CT is also proposed. It has a multipole wiggler as a light source and it mainly consists of a dual crystal monochromator and a rotating filter for attenuating photon flux of x rays and two-dimensional detector.


Asunto(s)
Iluminación , Imagen Radiográfica por Emisión de Doble Fotón , Sincrotrones , Tomografía Computarizada por Rayos X , Diseño de Equipo , Modelos Teóricos , Imagen Radiográfica por Emisión de Doble Fotón/instrumentación , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos
10.
Med Phys ; 28(1): 16-21, 2001 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-11213917

RESUMEN

Coronary cineangiography using synchrotron radiation is anticipated, owing to the high intensity and availability of monoenergy. To investigate allowable dose levels in clinical application, absorbed dose distribution in a tissue substitute phantom for a conventional x-ray machine was measured with thermoluminescent dosimeters at the University of Tsukuba under the practical conditions used for digital angiography. The dose rate at a 0.5-cm depth was 0.145 Gy/s, and the dose per frame was 0.725 mGy for the irradiation period of 5 ms per frame. For synchrotron radiation, the dose distribution measurement was made at a 5-GeV AR (Accumulation Ring) of the High Energy Accelerator Research Organization, in which a polymethylmethacrylate (PMMA) phantom was irradiated with the strongest beam available at the facility, which was 33.32 keV, 5.2 x 6.2 cm2 beam. Using this beam, a 1-mm-diameter coronary artery has been visualized at 1% iodine concentration at the AR. Nonhomogeneous strength distribution in the beam was observed in the vertical direction. The maximum dose rate was 0.556 Gy/s, and it attenuated to 1/3000 at a 30-cm depth in the beam center. At the deep positions, the doses were influenced by the high harmonics, which was confirmed with an EGS4 Monte Carlo calculation. Outside the beam, beam contamination on both sides of the main beam affected the doses. For comparison to the x-ray machine, the measured dose was analytically converted to that needed for a 5.2 x 16 cm2 beam that is used for clinical application. The dose rate at 0.5-cm depth was found to be 0.215 Gy/s, which is 1.48 times larger than that for x-rays. Moreover, the attenuation rate in the phantom was significantly greater than that of the x-ray machine, because of the difference of the energy spectra between the x-rays and synchrotron radiation used.


Asunto(s)
Angiografía Coronaria/instrumentación , Sincrotrones/instrumentación , Fenómenos Biofísicos , Biofisica , Angiografía Coronaria/métodos , Humanos , Fantasmas de Imagen , Dosis de Radiación , Tecnología Radiológica , Dosimetría Termoluminiscente
11.
Phys Med Biol ; 43(11): 3235-59, 1998 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-9832014

RESUMEN

Accurate dosimetry is particularly difficult for low- to medium-energy x-rays as various interaction processes with different dependences on material properties determine the dose distribution in tissue and radiation detectors. Monoenergetic x-rays from synchrotron radiation offer the unique opportunity to study the dose response variation with photon energy of radiation detectors without the compounding effect of the spectral distribution of x-rays from conventional sources. The variation of dose response with photon energies between 10 and 99.6 keV was studied for two TLD materials (LiF:Mg,Ti and LiF:Mg,Cu,P), MOSFET semiconductors, radiographic and radiochromic film. The dose response at synchrotron radiation energies was compared with the one for several superficial/orthovoltage radiation qualities (HVL 1.4 mm Al to 4 mm Cu) and megavoltage photons from a medical linear accelerator. A calibrated parallel plate ionization chamber was taken as the reference dosimeter. The variation of response with x-ray energy was modelled using a two-component model that allows determination of the energy for maximum response as well as its magnitude. MOSFET detectors and the radiographic film were found to overrespond to low-energy x-rays by up to a factor of 7 and 12 respectively, while the radiochromic film underestimated the dose by approximately a factor of 2 at 24 keV. The TLDs showed a slight overresponse with LiF:Mg, Cu, P demonstrating better tissue equivalence than LiF:Mg, Ti (maximum deviation from water less than 25%). The results of the present study demonstrate the usefulness of monoenergetic photons for the study of the energy response of radiation detectors. The variations in energy response observed for the MOSFET detectors and GAF chromic film emphasize the need for a correction for individual dosimeters if accurate dosimetry of low- to medium-energy x-rays is attempted.


Asunto(s)
Radiometría/instrumentación , Sincrotrones , Fenómenos Biofísicos , Biofisica , Humanos , Modelos Biológicos , Fotones/uso terapéutico , Radiometría/normas , Dosificación Radioterapéutica , Dosimetría Termoluminiscente , Película para Rayos X
12.
Acad Radiol ; 2(7): 602-8, 1995 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-9419611

RESUMEN

RATIONALE AND OBJECTIVES: For intravenous (i.v.) coronary arteriography, a real-time two-dimensional (2D) imaging system is being developed using above-K-edge monochromatic X-rays alone. The potential diagnostic value of this system was examined in the current study. METHODS: The angiographic system consisted of an asymmetric silicon (311) monocrystal, an image intensifier, and a charged-coupled device camera. It was constructed at the beam line of the Tristan Accumulation Ring. Monochromatic X-rays of 33.32 keV were used, and each image was recorded over 2 msec. RESULTS: Ventricular wall motion and the anatomy of the coronary arteries could be seen in dogs by sequential images obtained without subtraction. The left anterior descending coronary artery, left circumflex coronary artery, and right coronary artery and the branches of these vessels were observed. The parts of the coronary arteries overlapping the aorta and left ventricle were revealed somewhat during washout of the contrast material. CONCLUSION: For a 2D imaging system, monochromatic i.v. coronary angiography using an energy above the iodine K-edge might be able to image the coronary arteries without subtraction. However, the image quality needs to be improved by increasing the X-ray flux, decreasing background radiation scatter from the object, and decreasing contamination with 99-keV X-rays.


Asunto(s)
Medios de Contraste/administración & dosificación , Angiografía Coronaria/métodos , Vasos Coronarios , Procesamiento de Imagen Asistido por Computador , Sincrotrones , Animales , Aortografía/métodos , Angiografía Coronaria/instrumentación , Perros , Ventrículos Cardíacos/diagnóstico por imagen , Inyecciones Intravenosas , Intensificación de Imagen Radiográfica , Grabación en Video
13.
Br J Radiol ; 72(853): 24-8, 1999 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-10341685

RESUMEN

A method of examination for coronary artery disease that is less invasive and easier than coronary angiography (CAG) has been sought. We have developed a dynamic intravenous coronary angiography (IVCAG) system using synchrotron radiation (SR) and have used it clinically. Four patients suspected of having angina pectoris underwent IVCAG. An SR beam was reflected asymmetrically with a silicon crystal to produce a wide (150 mm x 80 mm) and monochromatic (37 keV) X-ray beam, with an energy level to achieve high sensitivity to the contrast agent. Following an intravenous injection of contrast agent, irradiation was applied for 4 ms periods at 33 ms intervals for dynamic IVCAG at 30 images s-1. Images were acquired with an image intensifier and recorded with a digital fluorography system. The dynamic images permitted clear visualization of the coronary arteries and permitted evaluation of coronary anatomy. Two patients exhibited no stenotic lesions, one patient had a 90% stenosis in the right coronary artery, and the remaining patient had a 25% stenosis at the site of previous percutaneous transluminal coronary angioplasty in the left anterior descending artery (LAD). The total irradiation doses used for IVCAG were less than those for conventional angiography. Dynamic IVCAG can be readily used for the evaluation of coronary arteries.


Asunto(s)
Angiografía Coronaria/métodos , Enfermedad Coronaria/diagnóstico por imagen , Sincrotrones , Anciano , Medios de Contraste/administración & dosificación , Humanos , Inyecciones Intravenosas , Masculino , Persona de Mediana Edad
14.
Australas Phys Eng Sci Med ; 19(4): 225-36, 1996 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-9060209

RESUMEN

Thermoluminescence dosimetry (TLD) is a versatile technique with many applications for dosimetry of ionising radiation. However, in the range of kilovoltage x-rays which is widely used for diagnostic and therapeutic medical applications, problems arise from the differing dose response of most TL dosimeters with the radiation energy. The dose response of various TL detector types was investigated in mono-energetic x-ray beams of 26.8, 33.2, 40, 80.4 and 99.6keV from a synchrotron radiation source at the National Laboratory for High Energy Physics in Japan. This response was studied as a function of TL material (LiF:Mg,Ti, LiF:Mg,Cu,P and Al2O3), the detector geometry and size, and their thermal history. Due to the asymmetric diffraction from a Si crystal employed to produce monoenergetic photons there was more than 50% dose inhomogeneity in some of radiation fields used. Therefore, the different TL dosimeter types were rotated around and the results related to the reading of a set of "standard" LiF:Mg,Ti ribbons which were included in all experiments as reference detectors. No significant influence of the detector shape (physical size, thickness) on the dose response with energy could be found. However, the pre-irradiation thermal history influences the dose response with radiation energy: a fast cool down of LiF:Mg,Ti after a high temperature anneal will increase the sensitivity by more than a factor of two. The relatively new TLD material LiF:Mg,Cu,P (GR-200, obtained from Solid Dosimeter & Detector Laboratories, Beijing) was found to be approximately 100 times more sensitive than the standard LiF:Mg,Ti. In addition it proved to be more tissue equivalent for photon radiation between 27keV and 40keV. The performance of LiF:Mg,Cu,P makes it a very interesting TL material deserving further evaluation for applications in diagnostic and therapeutic x-rays.


Asunto(s)
Ensayo de Materiales , Sincrotrones , Dosimetría Termoluminiscente/instrumentación , Óxido de Aluminio , Cobre , Fluoruros , Compuestos de Litio , Magnesio , Fósforo , Radiación Ionizante , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Dosimetría Termoluminiscente/normas
15.
Rinsho Byori ; 49(5): 512-21, 2001 May.
Artículo en Japonés | MEDLINE | ID: mdl-11402574

RESUMEN

In Fukuoka whose population is approximately five million inhabitants, surveys on the accuracy of laboratory data have been performed by the Fukuoka Prefecture Medical Association for the last 30 years. We have been attempting to evaluate the data for routine use since 1988, and it has become possible to share laboratory data between all institutions in Fukuoka prefectures. As a result, reference intervals for 23 clinical chemistry analytes were established in 1995, to which were added in 1996 five serum protein constituents that have been utilized for clinical examinations. Methods for documentations and monitorings the data obtained in the prefecture were also established, standardization of the above analytes extended to 97% of the institutions in the prefecture. Results for 14 of the 23 clinical chemistry analytes have become highly reliable and clinically useful as differences between institutions in terms of results have narrowed. Standardization of other analytes is now in progress.


Asunto(s)
Técnicas de Laboratorio Clínico/normas , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Japón , Masculino , Persona de Mediana Edad , Control de Calidad , Valores de Referencia
16.
Shinrigaku Kenkyu ; 70(2): 104-11, 1999 Jun.
Artículo en Japonés | MEDLINE | ID: mdl-10488495

RESUMEN

This study assessed how time brings out changes in one's mental and physical reactions to traumatic experiences. Two surveys were conducted on students of Kobe College, located at one of the areas hardest hit by the Hanshin-Awaji Earthquake in January, 1995. Much of the traumatic reactions decreased in strength through January to March, while feelings of survival guilt did not. Guilt feelings of those whose housing were destroyed increased in March, and kept its level even in October. Although general health conditions of those surveyed in October was normal, several post-traumatic reactions increased in October as compared with March. The rate of recovery from post-traumatic reactions seemed to very according to the depth of one's psychological suffering, to one's financial situation, and to the presence of social support. The factor analysis on the items of mental and physical reactions yielded seven factors. The factor of highest eigenvalue in January was one named "anxiety about after-quake tremors", however, this was replaced by one named "emotional confusions" in March.


Asunto(s)
Desastres , Trastornos por Estrés Postraumático/psicología , Recolección de Datos , Femenino , Humanos , Estudiantes , Factores de Tiempo
17.
Artículo en Inglés | MEDLINE | ID: mdl-24111122

RESUMEN

This study verified the accuracy of the speed of sound (SOS) measured by the combination method, which calculates the ratio between the thickness values of cartilage measured by using the magnetic resonance imaging (MRI) and the ultrasonic pulse-echo imaging, and investigated in vivo application of this method. SOS specific to an ultrasound imaging device was used as a reference value to calculate the actual SOS from the ratio of cartilage thicknesses obtained from MR and ultrasound images. The accuracy of the thickness measurement was verified by comparing results obtained using MRI and a non-contact laser, and the accuracy of the calculated SOS was confirmed by comparing results of the pulse-echo and transmission methods in vitro. The difference between laser and MRI measurements was 0.05 ± 0.22 mm. SOS values in a human knee measured by the combination method in the medial and lateral femoral condyles were 1650 ± 79 and 1642 ± 78 m/s, respectively (p < 0.05). The results revealed the feasibility of in situ SOS measurement using the combination method.


Asunto(s)
Cartílago Articular/diagnóstico por imagen , Cartílago Articular/patología , Imagen por Resonancia Magnética , Sonido , Adulto , Animales , Femenino , Humanos , Rodilla/patología , Articulación de la Rodilla/patología , Rayos Láser , Persona de Mediana Edad , Fantasmas de Imagen , Valores de Referencia , Reproducibilidad de los Resultados , Porcinos , Ultrasonografía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA