Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Nature ; 438(7068): 639-42, 2005 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-16319885

RESUMEN

Among the classes of highly entangled states of multiple quantum systems, the so-called 'Schrödinger cat' states are particularly useful. Cat states are equal superpositions of two maximally different quantum states. They are a fundamental resource in fault-tolerant quantum computing and quantum communication, where they can enable protocols such as open-destination teleportation and secret sharing. They play a role in fundamental tests of quantum mechanics and enable improved signal-to-noise ratios in interferometry. Cat states are very sensitive to decoherence, and as a result their preparation is challenging and can serve as a demonstration of good quantum control. Here we report the creation of cat states of up to six atomic qubits. Each qubit's state space is defined by two hyperfine ground states of a beryllium ion; the cat state corresponds to an entangled equal superposition of all the atoms in one hyperfine state and all atoms in the other hyperfine state. In our experiments, the cat states are prepared in a three-step process, irrespective of the number of entangled atoms. Together with entangled states of a different class created in Innsbruck, this work represents the current state-of-the-art for large entangled states in any qubit system.

2.
Nature ; 429(6993): 737-9, 2004 Jun 17.
Artículo en Inglés | MEDLINE | ID: mdl-15201904

RESUMEN

Quantum teleportation provides a means to transport quantum information efficiently from one location to another, without the physical transfer of the associated quantum-information carrier. This is achieved by using the non-local correlations of previously distributed, entangled quantum bits (qubits). Teleportation is expected to play an integral role in quantum communication and quantum computation. Previous experimental demonstrations have been implemented with optical systems that used both discrete and continuous variables, and with liquid-state nuclear magnetic resonance. Here we report unconditional teleportation of massive particle qubits using atomic (9Be+) ions confined in a segmented ion trap, which aids individual qubit addressing. We achieve an average fidelity of 78 per cent, which exceeds the fidelity of any protocol that does not use entanglement. This demonstration is also important because it incorporates most of the techniques necessary for scalable quantum information processing in an ion-trap system.

3.
Nature ; 432(7017): 602-5, 2004 Dec 02.
Artículo en Inglés | MEDLINE | ID: mdl-15577904

RESUMEN

Scalable quantum computation and communication require error control to protect quantum information against unavoidable noise. Quantum error correction protects information stored in two-level quantum systems (qubits) by rectifying errors with operations conditioned on the measurement outcomes. Error-correction protocols have been implemented in nuclear magnetic resonance experiments, but the inherent limitations of this technique prevent its application to quantum information processing. Here we experimentally demonstrate quantum error correction using three beryllium atomic-ion qubits confined to a linear, multi-zone trap. An encoded one-qubit state is protected against spin-flip errors by means of a three-qubit quantum error-correcting code. A primary ion qubit is prepared in an initial state, which is then encoded into an entangled state of three physical qubits (the primary and two ancilla qubits). Errors are induced simultaneously in all qubits at various rates. The encoded state is decoded back to the primary ion one-qubit state, making error information available on the ancilla ions, which are separated from the primary ion and measured. Finally, the primary qubit state is corrected on the basis of the ancillae measurement outcome. We verify error correction by comparing the corrected final state to the uncorrected state and to the initial state. In principle, the approach enables a quantum state to be maintained by means of repeated error correction, an important step towards scalable fault-tolerant quantum computation using trapped ions.

4.
Science ; 237(4815): 612-7, 1987 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-17758560

RESUMEN

Recent developments in laser spectroscopy of atomic ions stored in electromagnetic traps are reviewed with emphasis on techniques that appear to hold the greatest promise of attaining extremely high resolution. Among these techniques are laser cooling and the use of single, isolated ions as experimental samples. Doppler shifts and other perturbing influences can be largely eliminated. Atomic resonances with line widths of a few parts in 10(11) have been observed at frequencies ranging from the radio frequency to the ultraviolet. Experimental accuracies of one part in 10(18) appear to be attainable.

5.
Science ; 291(5506): 1013-5, 2001 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-11232562

RESUMEN

We demonstrate a decoherence-free quantum memory of one qubit. By encoding the qubit into the decoherence-free subspace (DFS) of a pair of trapped 9Be+ ions, we protect the qubit from environment-induced dephasing that limits the storage time of a qubit composed of a single ion. We measured the storage time under ambient conditions and under interaction with an engineered noisy environment and observed that encoding into the DFS increases the storage time by up to an order of magnitude. The encoding reversibly transfers an arbitrary qubit stored in a single ion to the DFS of two ions.

6.
Science ; 293(5531): 825-8, 2001 Aug 03.
Artículo en Inglés | MEDLINE | ID: mdl-11452082

RESUMEN

Microwave atomic clocks have been the de facto standards for precision time and frequency metrology over the past 50 years, finding widespread use in basic scientific studies, communications, and navigation. However, with its higher operating frequency, an atomic clock based on an optical transition can be much more stable. We demonstrate an all-optical atomic clock referenced to the 1.064-petahertz transition of a single trapped 199Hg+ ion. A clockwork based on a mode-locked femtosecond laser provides output pulses at a 1-gigahertz rate that are phase-coherently locked to the optical frequency. By comparison to a laser-cooled calcium optical standard, an upper limit for the fractional frequency instability of 7 x 10(-15) is measured in 1 second of averaging-a value substantially better than that of the world's best microwave atomic clocks.

7.
J Res Natl Inst Stand Technol ; 105(6): 829-37, 2000.
Artículo en Inglés | MEDLINE | ID: mdl-27551639

RESUMEN

Frequency shifts of the (199)Hg(+) 5d (10)6s (2)S1/2 (F = 0, MF = 0) to 5d (9)6s (2 2)D5/2 (F = 2, MF = 0) electric-quadrupole transition at 282 nm due to external fields are calculated, based on a combination of measured atomic parameters and ab initio calculations. This transition is under investigation as an optical frequency standard. The perturbations calculated are the quadratic Zeeman shift, the scalar and tensor quadratic Stark shifts, and the interaction between an external electric field gradient and the atomic quadrupole moment. The quadrupole shift is likely to be the most difficult to evaluate in a frequency standard and may have a magnitude of about 1 Hz for a single ion in a Paul trap.

8.
J Res Natl Inst Stand Technol ; 103(3): 259-328, 1998.
Artículo en Inglés | MEDLINE | ID: mdl-28009379

RESUMEN

Methods for, and limitations to, the generation of entangled states of trapped atomic ions are examined. As much as possible, state manipulations are described in terms of quantum logic operations since the conditional dynamics implicit in quantum logic is central to the creation of entanglement. Keeping with current interest, some experimental issues in the proposal for trappedion quantum computation by J. I. Cirac and P. Zoller (University of Innsbruck) are discussed. Several possible decoherence mechanisms are examined and what may be the more important of these are identified. Some potential applications for entangled states of trapped-ions which lie outside the immediate realm of quantum computation are also discussed.

9.
J Res Natl Inst Stand Technol ; 106(1): 47-63, 2001.
Artículo en Inglés | MEDLINE | ID: mdl-27500017

RESUMEN

The development of atomic frequency standards at NIST is discussed and three of the key frequency-standard technologies of the current era are described. For each of these technologies, the most recent NIST implementation of the particular type of standard is described in greater detail. The best relative standard uncertainty achieved to date for a NIST frequency standard is 1.5×10(-15). The uncertainties of the most recent NIST standards are displayed relative to the uncertainties of atomic frequency standards of several other countries.

10.
Artículo en Inglés | MEDLINE | ID: mdl-18285072

RESUMEN

Experiments directed toward the realization of frequency standards of high accuracy using stored ions are briefly summarized. In one experiment, an RF oscillator is locked to a nuclear spin-flip hyperfine transition (frequency approximately 3.03x10(8) Hz) in (9 )Be(+) ions that are stored in a Penning trap and sympathetically laser-cooled. Stability is better than 3x10(-12)tau(-(1/2)) and uncertainty in Doppler shifts is estimated to be less than 5x10(-15). In a second experiment, a stable laser is used to probe an electric quadrupole transition (frequency approximately 1.07x10(15) Hz) in a single laser-cooled (199)Hg(+) ion stored in a Paul trap. The measured Q value of this transition is approximately 10(13). Future possible experiments are discussed.

11.
Science ; 319(5871): 1808-12, 2008 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-18323415

RESUMEN

Time has always had a special status in physics because of its fundamental role in specifying the regularities of nature and because of the extraordinary precision with which it can be measured. This precision enables tests of fundamental physics and cosmology, as well as practical applications such as satellite navigation. Recently, a regime of operation for atomic clocks based on optical transitions has become possible, promising even higher performance. We report the frequency ratio of two optical atomic clocks with a fractional uncertainty of 5.2 x 10(-17). The ratio of aluminum and mercury single-ion optical clock frequencies nuAl+/nuHg+ is 1.052871833148990438(55), where the uncertainty comprises a statistical measurement uncertainty of 4.3 x 10(-17), and systematic uncertainties of 1.9 x 10(-17) and 2.3 x 10(-17) in the mercury and aluminum frequency standards, respectively. Repeated measurements during the past year yield a preliminary constraint on the temporal variation of the fine-structure constant alpha of alpha/alpha = (-1.6+/-2.3) x 10(-17)/year.

12.
Phys Rev Lett ; 98(7): 070801, 2007 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-17359009

RESUMEN

We report tests of local position invariance and the variation of fundamental constants from measurements of the frequency ratio of the 282-nm 199Hg+ optical clock transition to the ground state hyperfine splitting in 133Cs. Analysis of the frequency ratio of the two clocks, extending over 6 yr at NIST, is used to place a limit on its fractional variation of <5.8x10(-6) per change in normalized solar gravitational potential. The same frequency ratio is also used to obtain 20-fold improvement over previous limits on the fractional variation of the fine structure constant of |alpha/alpha|<1.3x10(-16) yr-1, assuming invariance of other fundamental constants. Comparisons of our results with those previously reported for the absolute optical frequency measurements in H and 171Yb+ vs other 133Cs standards yield a coupled constraint of -1.5x10(-15)

13.
Phys Rev Lett ; 98(22): 220801, 2007 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-17677830

RESUMEN

We report, for the first time, laser spectroscopy of the 1S0-->3P0 clock transition in 27Al+. A single aluminum ion and a single beryllium ion are simultaneously confined in a linear Paul trap, coupled by their mutual Coulomb repulsion. This coupling allows the beryllium ion to sympathetically cool the aluminum ion and also enables transfer of the aluminum's electronic state to the beryllium's hyperfine state, which can be measured with high fidelity. These techniques are applied to measure the clock transition frequency nu=1,121,015,393,207,851(6) Hz. They are also used to measure the lifetime of the metastable clock state tau=20.6+/-1.4 s, the ground state 1S0 g factor gS=-0.000,792,48(14), and the excited state 3P0 g factor gP=-0.001,976,86(21), in units of the Bohr magneton.

14.
Phys Rev Lett ; 96(25): 253003, 2006 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-16907302

RESUMEN

Individual laser-cooled 24Mg+ ions are confined in a linear Paul trap with a novel geometry where gold electrodes are located in a single plane and the ions are trapped 40 microm above this plane. The relatively simple trap design and fabrication procedure are important for large-scale quantum information processing (QIP) using ions. Measured ion motional frequencies are compared to simulations. Measurements of ion recooling after cooling is temporarily suspended yield a heating rate of approximately 5 motional quanta per millisecond for a trap frequency of 2.83 MHz, sufficiently low to be useful for QIP.

15.
Phys Rev Lett ; 97(2): 020801, 2006 Jul 14.
Artículo en Inglés | MEDLINE | ID: mdl-16907426

RESUMEN

For the past 50 years, atomic standards based on the frequency of the cesium ground-state hyperfine transition have been the most accurate time pieces in the world. We now report a comparison between the cesium fountain standard NIST-F1, which has been evaluated with an inaccuracy of about 4 x 10(-16), and an optical frequency standard based on an ultraviolet transition in a single, laser-cooled mercury ion for which the fractional systematic frequency uncertainty was below 7.2 x 10(-17). The absolute frequency of the transition was measured versus cesium to be 1,064,721,609,899,144.94 (97) Hz, with a statistically limited total fractional uncertainty of 9.1 x 10(-16) the most accurate absolute measurement of an optical frequency to date.

16.
Phys Rev Lett ; 94(16): 163001, 2005 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-15904220

RESUMEN

The electric-quadrupole moment of the (199)Hg+ 5d9 6s2 (2)D(5/2) state is measured to be theta(D,5/2) = -2.29(8) x 10(-40) C m2. This value was determined by measuring the frequency of the (199)Hg+ 5d10 6s (2)S(1/2) --> 5d9 6s2 (2)D(5/2) optical clock transition for different applied electric-field gradients. An isolated, mechanically stable optical cavity provides a frequency reference for the measurement. We compare the results with theoretical calculations and discuss the implications for the accuracy of an atomic clock based upon this transition. We now expect that the frequency shift caused by the interaction of the quadrupole moment with stray electric-field gradients will not limit the accuracy of the Hg+ optical clock at the 10(-18) level.

17.
Science ; 309(5735): 749-52, 2005 Jul 29.
Artículo en Inglés | MEDLINE | ID: mdl-16051790

RESUMEN

We present a general technique for precision spectroscopy of atoms that lack suitable transitions for efficient laser cooling, internal state preparation, and detection. In our implementation with trapped atomic ions, an auxiliary "logic" ion provides sympathetic laser cooling, state initialization, and detection for a simultaneously trapped "spectroscopy" ion. Detection is achieved by applying a mapping operation to each ion, which results in a coherent transfer of the spectroscopy ion's internal state onto the logic ion, where it is then measured with high efficiency. Experimental realization, by using 9Be+ as the logic ion and 27Al+ as the spectroscopy ion, indicates the feasibility of applying this technique to make accurate optical clocks based on single ions.

18.
Phys Rev Lett ; 94(1): 010501, 2005 Jan 14.
Artículo en Inglés | MEDLINE | ID: mdl-15698054

RESUMEN

We investigate theoretically and experimentally how quantum state-detection efficiency is improved by the use of quantum information processing (QIP). Experimentally, we encode the state of one 9Be(+) ion qubit with one additional ancilla qubit. By measuring both qubits, we reduce the state-detection error in the presence of noise. The deviation from the theoretically allowed reduction is due to infidelities of the QIP operations. Applying this general scheme to more ancilla qubits suggests that error in the individual qubit measurements need not be a limit to scalable quantum computation.

19.
Science ; 308(5724): 997-1000, 2005 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-15890877

RESUMEN

We report the implementation of the semiclassical quantum Fourier transform in a system of three beryllium ion qubits (two-level quantum systems) confined in a segmented multizone trap. The quantum Fourier transform is the crucial final step in Shor's algorithm, and it acts on a register of qubits to determine the periodicity of the quantum state's amplitudes. Because only probability amplitudes are required for this task, a more efficient semiclassical version can be used, for which only single-qubit operations conditioned on measurement outcomes are required. We apply the transform to several input states of different periodicities; the results enable the location of peaks corresponding to the original periods. This demonstration incorporates the key elements of a scalable ion-trap architecture, suggesting the future capability of applying the quantum Fourier transform to a large number of qubits as required for a useful quantum factoring algorithm.

20.
Phys Rev Lett ; 95(3): 030403, 2005 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-16090723

RESUMEN

The coherence of a hyperfine-state superposition of a trapped 9Be+ ion in the presence of off-resonant light is studied experimentally. It is shown that Rayleigh elastic scattering of photons that does not change state populations also does not affect coherence. We observe coherence times that exceed the average scattering time of 19 photons which is determined from measured Stark shifts. This result implies that, with sufficient control over its parameters, laser light can be used to manipulate hyperfine-state superpositions with very little decoherence.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA