Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Ann Surg ; 276(5): 913-920, 2022 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-35894448

RESUMEN

OBJECTIVE: The aim was to compare the (sentinel) lymph node detection rate of indocyanine green (ICG)-fluorescent imaging versus standard-of-care 99m Tc-nanocoilloid for sentinel lymph node (SLN)-mapping. BACKGROUND: The current gold standard for axillary staging in patients with breast cancer is sentinel lymph node biopsy (SLNB) using radio-guided surgery using radioisotope technetium ( 99m Tc), sometimes combined with blue dye. A promising alternative is fluorescent imaging using ICG. METHODS: In this noninferiority trial, we enrolled 102 consecutive patients with invasive early-stage, clinically node-negative breast cancer. Patients were planned for breast conserving surgery and SLNB between August 2020 and June 2021. The day or morning before surgery, patients were injected with 99m Tc-nanocolloid. In each patient, SLNB was first performed using ICG-fluorescent imaging, after which excised lymph nodes were tested with the gamma-probe for 99m Tc-uptake ex vivo, and the axilla was checked for residual 99m Tc-activity. The detection rate was defined as the proportion of patients in whom at least 1 (S)LN was detected with either tracer. RESULTS: In total, 103 SLNBs were analyzed. The detection rate of ICG-fluorescence was 96.1% [95% confidence interval (95% CI)=90.4%-98.9%] versus 86.4% (95% CI=78.3%-92.4%) for 99m Tc-nanocoilloid. The detection rate for pathological lymph nodes was 86.7% (95% CI=59.5%-98.3%) for both ICG and 99m Tc-nanocoilloid. A median of 2 lymph nodes were removed. ICG-fluorescent imaging did not increase detection time. No adverse events were observed. CONCLUSIONS: ICG-fluorescence showed a higher (S)LN detection rate than 99m Tc-nanocoilloid, and equal detection rate for pathological (S)LNs. ICG-fluorescence may be used as a safe and effective alternative to 99m Tc-nanocoilloid for SLNB in patients with early-stage breast cancer.


Asunto(s)
Neoplasias de la Mama , Ganglio Linfático Centinela , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Neoplasias de la Mama/cirugía , Colorantes , Femenino , Humanos , Verde de Indocianina , Ganglios Linfáticos/diagnóstico por imagen , Ganglios Linfáticos/patología , Linfocintigrafia/métodos , Radiofármacos , Ganglio Linfático Centinela/diagnóstico por imagen , Ganglio Linfático Centinela/patología , Ganglio Linfático Centinela/cirugía , Biopsia del Ganglio Linfático Centinela/métodos , Tecnecio , Agregado de Albúmina Marcado con Tecnecio Tc 99m
2.
BJS Open ; 7(5)2023 09 05.
Artículo en Inglés | MEDLINE | ID: mdl-37751322

RESUMEN

BACKGROUND: Accurate tumour localization is crucial for precise surgical targeting and complete tumour removal. Indocyanine green fluorescence, an increasingly used technique in oncological surgery, has shown promise in localizing non-palpable breast tumours. The aim of this systematic review was to describe the efficacy of indocyanine green fluorescence for the identification of non-palpable breast tumours. METHODS: A systematic literature search was performed in PubMed, Embase, and the Cochrane Library, including studies from 2012 to 2023. Studies reporting the proportion of breast tumours identified using indocyanine green fluorescence were included. The quality of the studies and their risk of bias were appraised using the Methodological Index for Non-Randomized Studies ('MINORS') tool. The following outcomes were collected: identification rate, clear resection margins, specimen volume, operative time, re-operation rate, adverse events, and complications. RESULTS: In total, 2061 articles were screened for eligibility, resulting in 11 studies, with 366 patients included: two RCTs, three non-randomized comparative studies, four single-arm studies, and two case reports. All studies achieved a 100 per cent tumour identification rate with indocyanine green fluorescence, except for one study, with an identification rate of 87 per cent (13/15). Clear resection margins were found in 88-100 per cent of all patients. Reoperation rates ranged from 0.0 to 5.4 per cent and no complications or adverse events related to indocyanine green occurred. CONCLUSION: Indocyanine green fluorescence has substantial theoretical advantages compared with current routine localization methods. Although a limited number of studies were available, the current literature suggests that indocyanine green fluorescence is a useful, accurate, and safe technique for the intraoperative localization of non-palpable breast tumours, with equivalent efficacy compared with other localization techniques, potentially reducing tumour-positive margins.


Asunto(s)
Neoplasias de la Mama , Verde de Indocianina , Humanos , Femenino , Fluorescencia , Márgenes de Escisión , Tempo Operativo , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA