RESUMEN
WHAT WE ALREADY KNOW ABOUT THIS TOPIC: WHAT THIS ARTICLE TELLS US THAT IS NEW: BACKGROUND:: Respiratory muscle weakness in critically ill patients is associated with difficulty in weaning from mechanical ventilation. Previous studies have mainly focused on inspiratory muscle activity during weaning; expiratory muscle activity is less well understood. The current study describes expiratory muscle activity during weaning, including tonic diaphragm activity. The authors hypothesized that expiratory muscle effort is greater in patients who fail to wean compared to those who wean successfully. METHODS: Twenty adult patients receiving mechanical ventilation (more than 72 h) performed a spontaneous breathing trial. Tidal volume, transdiaphragmatic pressure, diaphragm electrical activity, and diaphragm neuromechanical efficiency were calculated on a breath-by-breath basis. Inspiratory (and expiratory) muscle efforts were calculated as the inspiratory esophageal (and expiratory gastric) pressure-time products, respectively. RESULTS: Nine patients failed weaning. The contribution of the expiratory muscles to total respiratory muscle effort increased in the "failure" group from 13 ± 9% at onset to 24 ± 10% at the end of the breathing trial (P = 0.047); there was no increase in the "success" group. Diaphragm electrical activity (expressed as the percentage of inspiratory peak) was low at end expiration (failure, 3 ± 2%; success, 4 ± 6%) and equal between groups during the entire expiratory phase (P = 0.407). Diaphragm neuromechanical efficiency was lower in the failure versus success groups (0.38 ± 0.16 vs. 0.71 ± 0.36 cm H2O/µV; P = 0.054). CONCLUSIONS: Weaning failure (vs. success) is associated with increased effort of the expiratory muscles and impaired neuromechanical efficiency of the diaphragm but no difference in tonic activity of the diaphragm.
Asunto(s)
Espiración/fisiología , Respiración Artificial/métodos , Insuficiencia Respiratoria/fisiopatología , Insuficiencia Respiratoria/terapia , Músculos Respiratorios/fisiología , Desconexión del Ventilador/métodos , Anciano , Anciano de 80 o más Años , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Respiración Artificial/efectos adversos , Mecánica Respiratoria/fisiología , Insuficiencia del Tratamiento , Desconexión del Ventilador/efectos adversosRESUMEN
Acetylcholine receptor antagonists have been shown to improve outcome in patients with severe acute respiratory distress syndrome. However, it is incompletely understood how these agents improve outcome. In the current editorial, we discuss the mechanisms of action of acetylcholine receptor antagonists beyond neuromuscular blockade.
Asunto(s)
Antagonistas Colinérgicos/farmacología , Síndrome de Dificultad Respiratoria/tratamiento farmacológico , Antagonistas Colinérgicos/uso terapéutico , Humanos , Fármacos Neuromusculares no Despolarizantes/farmacología , Fármacos Neuromusculares no Despolarizantes/uso terapéutico , Síndrome de Dificultad Respiratoria/fisiopatología , Resultado del TratamientoRESUMEN
BACKGROUND: Diaphragm dysfunction develops frequently in ventilated intensive care unit (ICU) patients. Both disuse atrophy (ventilator over-assist) and high respiratory muscle effort (ventilator under-assist) seem to be involved. A strong rationale exists to monitor diaphragm effort and titrate support to maintain respiratory muscle activity within physiological limits. Diaphragm electromyography is used to quantify breathing effort and has been correlated with transdiaphragmatic pressure and esophageal pressure. The neuromuscular efficiency index (NME) can be used to estimate inspiratory effort, however its repeatability has not been investigated yet. Our goal is to evaluate NME repeatability during an end-expiratory occlusion (NMEoccl) and its use to estimate the pressure generated by the inspiratory muscles (Pmus). METHODS: This is a prospective cohort study, performed in a medical-surgical ICU. A total of 31 adult patients were included, all ventilated in neurally adjusted ventilator assist (NAVA) mode with an electrical activity of the diaphragm (EAdi) catheter in situ. At four time points within 72 h five repeated end-expiratory occlusion maneuvers were performed. NMEoccl was calculated by delta airway pressure (ΔPaw)/ΔEAdi and was used to estimate Pmus. The repeatability coefficient (RC) was calculated to investigate the NMEoccl variability. RESULTS: A total number of 459 maneuvers were obtained. At time T = 0 mean NMEoccl was 1.22 ± 0.86 cmH2O/µV with a RC of 82.6%. This implies that when NMEoccl is 1.22 cmH2O/µV, it is expected with a probability of 95% that the subsequent measured NMEoccl will be between 2.22 and 0.22 cmH2O/µV. Additional EAdi waveform analysis to correct for non-physiological appearing waveforms, did not improve NMEoccl variability. Selecting three out of five occlusions with the lowest variability reduced the RC to 29.8%. CONCLUSIONS: Repeated measurements of NMEoccl exhibit high variability, limiting the ability of a single NMEoccl maneuver to estimate neuromuscular efficiency and therefore the pressure generated by the inspiratory muscles based on EAdi.
Asunto(s)
Enfermedad Crítica/terapia , Diafragma/fisiopatología , Eficiencia/fisiología , Estadística como Asunto/normas , Anciano , Estudios de Cohortes , Electromiografía/métodos , Femenino , Humanos , Unidades de Cuidados Intensivos/organización & administración , Soporte Ventilatorio Interactivo/métodos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Respiración Artificial/métodos , Índice de Severidad de la Enfermedad , Estadística como Asunto/métodos , Trabajo Respiratorio/fisiologíaRESUMEN
This article is one of ten reviews selected from the Annual Update in Intensive Care and Emergency medicine 2017. Other selected articles can be found online at http://ccforum.com/series/annualupdate2017 . Further information about the Annual Update in Intensive Care and Emergency Medicine is available from http://www.springer.com/series/8901 .
Asunto(s)
Manejo de la Vía Aérea/efectos adversos , Tiempo de Internación/estadística & datos numéricos , Músculos Respiratorios/metabolismo , Cardiotónicos/farmacología , Cardiotónicos/uso terapéutico , Humanos , Hidrazonas/farmacología , Hidrazonas/uso terapéutico , Unidades de Cuidados Intensivos/organización & administración , Atrofia Muscular/etiología , Piridazinas/farmacología , Piridazinas/uso terapéutico , Músculos Respiratorios/efectos de los fármacos , Músculos Respiratorios/fisiopatología , Simendán , Congéneres de la Testosterona/farmacología , Congéneres de la Testosterona/uso terapéuticoRESUMEN
OBJECTIVE: We evaluated whether urinary excretion of tubular injury markers could be useful for early detection of gentamicin (GM)-induced renal damage in neonates. STUDY DESIGN: We conducted a prospective, observational trial in neonates admitted to the neonatal intensive care unit (26 GM treated, 20 control). Kidney injury molecule-1 (KIM-1), neutrophil gelatinase-associated lipocalin (NGAL), N-acetyl-ß-D-glucosaminidase (NAG), and π- and α-glutathione-S-transferase (GSTP1-1 and GSTA1-1) were measured every 2 hours during admission and compared with serum creatinine (sCr) and urine output. RESULTS: Nine neonates developed AKI during the course of the study. The peak in excretion of urinary biomarkers preceded the peak in sCr (p < 0.0001). GM administration resulted in a more pronounced increase of sCr compared with control (13 [12-28] vs. 10 µmol/L [8.5-17]; p < 0.05). The urinary excretion of NAG (178 [104-698] vs. 32 ng/mol Cr [9-82]; p < 0.001) and NGAL (569 [168-1,681] vs. 222 ng/mol Cr [90-497]; p < 0.05) was higher in the GM group compared with control and preceded the peak of sCr and urine output decrease. CONCLUSION: GM administration to neonates is associated with renal damage reflected by a more pronounced increase in sCr preceded by urinary excretion of biomarkers. Urinary biomarkers may be useful for earlier identification of renal injury in neonates.
Asunto(s)
Lesión Renal Aguda/metabolismo , Antibacterianos/efectos adversos , Gentamicinas/efectos adversos , Edad Gestacional , Acetilglucosaminidasa/orina , Lesión Renal Aguda/inducido químicamente , Lesión Renal Aguda/diagnóstico , Proteínas de Fase Aguda/orina , Asfixia Neonatal , Biomarcadores/sangre , Biomarcadores/orina , Estudios de Cohortes , Anomalías Congénitas , Creatinina/sangre , Femenino , Gutatión-S-Transferasa pi/orina , Glutatión Transferasa/orina , Receptor Celular 1 del Virus de la Hepatitis A , Humanos , Recién Nacido , Recien Nacido Prematuro , Unidades de Cuidado Intensivo Neonatal , Lipocalina 2 , Lipocalinas/orina , Masculino , Glicoproteínas de Membrana/orina , Estudios Prospectivos , Proteínas Proto-Oncogénicas/orina , Receptores ViralesRESUMEN
Positive end-expiratory pressure (PEEP) is routinely applied in mechanically ventilated patients to improve gas exchange and respiratory mechanics by increasing end-expiratory lung volume (EELV). In a recent experimental study in rats, we demonstrated that prolonged application of PEEP causes diaphragm remodeling, especially longitudinal muscle fiber atrophy. This is of potential clinical importance, as the acute withdrawal of PEEP during ventilator weaning decreases EELV and thereby stretches the adapted, longitudinally atrophied diaphragm fibers to excessive sarcomere lengths, having a detrimental effect on force generation. Whether this series of events occurs in the human diaphragm is unknown. In the current study, we investigated if short-term application of PEEP affects diaphragm geometry and function, which are prerequisites for the development of longitudinal atrophy with prolonged PEEP application. Nineteen healthy volunteers were noninvasively ventilated with PEEP levels of 2, 5, 10, and 15 cmH2O. Magnetic resonance imaging was performed to investigate PEEP-induced changes in diaphragm geometry. Subjects were instrumented with nasogastric catheters to measure diaphragm neuromechanical efficiency (i.e., diaphragm pressure normalized to its electrical activity) during tidal breathing with different PEEP levels. We found that increasing PEEP from 2 to 15 cmH2O resulted in a caudal diaphragm displacement (19 [14-26] mm, P < 0.001), muscle shortening in the zones of apposition (20.6% anterior and 32.7% posterior, P < 0.001), increase in diaphragm thickness (36.4% [0.9%-44.1%], P < 0.001) and reduction in neuromechanical efficiency (48% [37.6%-56.6%], P < 0.001). These findings demonstrate that conditions required to develop longitudinal atrophy in the human diaphragm are present with the application of PEEP.NEW & NOTEWORTHY We demonstrate that PEEP causes changes in diaphragm geometry, especially muscle shortening, and decreases in vivo diaphragm contractile function. Thus, prerequisites for the development of diaphragm longitudinal muscle atrophy are present with the acute application of PEEP. Once confirmed in ventilated critically ill patients, this could provide a new mechanism for ventilator-induced diaphragm dysfunction and ventilator weaning failure in the intensive care unit (ICU).
Asunto(s)
Diafragma , Respiración Artificial , Animales , Humanos , Mediciones del Volumen Pulmonar , Respiración con Presión Positiva , Ratas , Respiración , Respiración Artificial/efectos adversosRESUMEN
INTRODUCTION: This narrative review summarizes current knowledge on the physiology and pathophysiology of expiratory muscle function in ICU patients, as shared by academic professionals from multidisciplinary, multinational backgrounds, who include clinicians, clinical physiologists and basic physiologists. RESULTS: The expiratory muscles, which include the abdominal wall muscles and some of the rib cage muscles, are an important component of the respiratory muscle pump and are recruited in the presence of high respiratory load or low inspiratory muscle capacity. Recruitment of the expiratory muscles may have beneficial effects, including reduction in end-expiratory lung volume, reduction in transpulmonary pressure and increased inspiratory muscle capacity. However, severe weakness of the expiratory muscles may develop in ICU patients and is associated with worse outcomes, including difficult ventilator weaning and impaired airway clearance. Several techniques are available to assess expiratory muscle function in the critically ill patient, including gastric pressure and ultrasound. CONCLUSION: The expiratory muscles are the "neglected component" of the respiratory muscle pump. Expiratory muscles are frequently recruited in critically ill ventilated patients, but a fundamental understanding of expiratory muscle function is still lacking in these patients.
Asunto(s)
Espiración/fisiología , Enfermedades Musculares/fisiopatología , Músculos Respiratorios/fisiopatología , Enfermedad Crítica , Humanos , Músculos Respiratorios/anomalías , Músculos Respiratorios/efectos de los fármacos , Trabajo Respiratorio/fisiologíaRESUMEN
The patient-ventilator breath contribution (PVBC) index estimates the relative contribution of the patient to total tidal volume (Vtinsp) during mechanical ventilation in neurally adjusted ventilator assist mode and has been used to titrate ventilator support. The reliability of this index in ventilated patients is unknown and was investigated in this study. PVBC was calculated by comparing tidal volume (Vtinsp) and diaphragm electrical activity (EAdi) during assisted breaths (Vtinsp/EAdi)assist and during unassisted breaths (Vtinsp/EAdi)no-assist. Vtinsp was normalized to peak EAdi (EAdipeak) using 1) one assisted breath, 2) five consecutive assisted breaths, or 3) five assisted breaths with matching EAdi preceding the unassisted breath (N1PVBC2, X5PVBC2, and PX5VBCEAdi-matching2 , respectively). In addition, PVBC was calculated by comparing only Vtinsp for breaths with matching EAdi (PVBCß2). Test-retest reliability of the different PVBC calculation methods was evaluated with the intraclass correlation coefficient (ICC) using five repeated PVBC maneuvers performed with a 1-min interval. In total, 125 PVBC maneuvers were analyzed in 25 patients. ICC [95% confidence interval] values were 0.46 [0.23-0.66], 0.51 [0.33-0.70], and 0.42 [0.14-0.69] for N1PVBC2, X5PVBC2, PX5VBCEAdi-matching2 , respectively. Complex waveform analyses showed that insufficient EAdi filtering by the ventilator software affects reliability of PVBC calculation. With our new EAdi-matching techniques reliability improved (PVBCß2 ICC: 0.78 [0.60-0.90]). We conclude that current techniques to calculate PVBC exhibit low reliability and that our newly developed criteria and estimation of PVBC-using Vtinsp of assisted breaths and unassisted breaths with matching EAdi-improves reliability. This may help implementation of PVBC in clinical practice. NEW & NOTEWORTHY The patient-ventilator breath contribution (PVBC) index estimates the relative contribution of the patient to tidal volume generated by the patient and the mechanical ventilator during mechanical ventilation in neurally adjusted ventilator assist mode. It could be used to titrate ventilator support and thus to limit development of diaphragm dysfunction in intensive care unit patients. Currently available methods for bedside assessment of PVBC are unreliable. Our newly developed criteria and estimation of PVBC largely improve reliability and help to quantify patient contribution to total inspiratory effort.