Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
BMC Med Imaging ; 15: 58, 2015 Dec 03.
Artículo en Inglés | MEDLINE | ID: mdl-26637242

RESUMEN

BACKGROUND: Objective of the study was to evaluate the diagnostic value of novel ultrasonographic modalities in comparison with simultaneously performed liver biopsy. METHODS: The results of simultaneously performed examinations using Acoustic Structure Quantification (ASQ), Virtual Touch Imaging and Quantification (VTIQ) and Virtual Touch Tissue Quantification (VTTQ) were compared with the findings of liver biopsy in patients with a wide variety of diffuse hepatopathies (n = 51). The histologically determined fibrosis stage according to Desmet and Scheuer was compared with quantitative measurements returned by the ultrasonographic imaging modalities. RESULTS: No statistically significant correlation with histologically determined fibrosis stage could be identified for any measurements returned using ASQ. Increasing severity of hepatic steatosis, however, was associated with a reduction in the focal disturbance (FD) ratio (r = -0.55; p < 0.0001). The shearwave velocities measured using VTTQ satisfyingly correlated with fibrosis stage (r = 0.56; p > 0.0001). Fibrosis stages > F2 were associated with an area under the curve (AUC) of 0.94 (95%-CI:0.84-0.99). A cut-off value for shearwave velocity of 1.66 m/s was determined with a sensitivity of 100% and a specificity of 84 %. VTIQ showed a less pronounced but acceptable correlation with fibrosis stage (r = 0.35; p = 0.0154). For fibrosis stages > F2 analysis showed an AUC of 0.84 (95%-CI:0.70-0.93). The cut-off value was 1.82 m/s with a sensitivity of 100% and a specificity of 58 %. CONCLUSION: While ASQ showed no diagnostic advantage in our patient collective, VTTQ showed high reliability for determining severe liver fibrosis in a group of patients with diffuse liver diseases of different etiology.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Hepatopatías/diagnóstico por imagen , Biopsia , Femenino , Humanos , Hepatopatías/patología , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Índice de Severidad de la Enfermedad
2.
Abdom Radiol (NY) ; 41(1): 25-32, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26830608

RESUMEN

PURPOSE: The aim of the study was to determine the sonographic prevalence of benign focal liver lesions on the basis of a population of hospital patients. METHODS: The ultrasound results in a population of (n = 45,319) hospital patients over a period of 10 years were examined retrospectively and evaluated for the diagnosis of benign focal liver lesions [hepatic cysts, hepatic hemangioma, focal nodular hyperplasia (FNH), hepatic adenoma, and focal fatty sparing]. Results that were incomplete or ambiguous were excluded from this study. RESULTS: At least one of the lesions to be investigated was diagnosed in 15.1% (n = 6839) of the patients of the total population. The most commonly recorded lesion, with a total prevalence of 6.3% (n = 2839), was focal fatty sparing, followed by hepatic cysts with 5.8% (n = 2631). The prevalence of hepatic hemangioma was 3.3% (n = 1640), while that of FNH was 0.2% (n = 81) and that of hepatic adenoma was 0.04% (n = 19). An association between the occurrence of benign focal liver lesions and age was observed. CONCLUSIONS: The calculated prevalence of benign focal liver lesions shows that on the fortuitous discovery of space-occupying lesions of the liver, first consideration should be given to focal fatty sparing, simple hepatic cysts and hemangiomas. The finding of a FNH or an adenoma is rarely a random discovery.


Asunto(s)
Hepatopatías/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Femenino , Alemania/epidemiología , Humanos , Lactante , Hepatopatías/epidemiología , Masculino , Persona de Mediana Edad , Prevalencia , Estudios Retrospectivos , Ultrasonografía
3.
J Med Ultrason (2001) ; 41(4): 445-53, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27278025

RESUMEN

PURPOSE: Qualitative and quantitative acoustic structure quantification (ASQ) is a new, noninvasive sonographic imaging method based on B-mode. This prospective clinical pilot study aims to answer the question whether delineation and measurement of liver lesions in hepatic alveolar echinococcosis (HAE) can be improved by ASQ. Furthermore, this is the first pilot study to explore how ASQ parameters in HAE lesions develop. METHODS: A total of 24 patients (male = 13/female = 11, mean age = 52 years (16-85), mean disease duration = 68 months (1-334)) with HAE were examined with ASQ using a Toshiba Aplio 500 unit. ASQ parameters were measured in HAE liver lesions and in adjacent non-tumor parenchyma. Quantitative analysis was performed offline using ASQ quantification software. RESULTS: Subjectively parasitic tumors in HAE appear more prominent in color-coded ASQ imaging, but the size of lesions measured in ASQ mode does not differ from size measurements in B-mode. Median focal disturbance ratio (FD ratio) in lesions was 3 (0.1-3), compared with 0.5 (0.1-1.8) in surrounding liver parenchyma (p < 0.0001). Statistical comparison of other ASQ parameters (mode, average, standard deviation) shows results that are similarly significant with p values between p < 0.0001 and p < 0.0018. CONCLUSION: ASQ is a promising sonographic method for examination and quantification of structural changes of liver parenchyma in HAE lesions.


Asunto(s)
Equinococosis Hepática/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Hígado/diagnóstico por imagen , Ultrasonografía/métodos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Programas Informáticos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA