Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
J Intensive Care Med ; 39(7): 628-635, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38190576

RESUMEN

Background: The likelihood of a patient being preload responsive-a state where the cardiac output or stroke volume (SV) increases significantly in response to preload-depends on both cardiac filling and function. This relationship is described by the canonical Frank-Starling curve. Research Question: We hypothesize that a novel method for phenotyping hypoperfused patients (ie, the "Doppler Starling curve") using synchronously measured jugular venous Doppler as a marker of central venous pressure (CVP) and corrected flow time of the carotid artery (ccFT) as a surrogate for SV will refine the pretest probability of preload responsiveness/unresponsiveness. Study Design and Methods: We retrospectively analyzed a prospectively collected convenience sample of hypoperfused adult emergency department (ED) patients. Doppler measurements were obtained before and during a preload challenge using a wireless, wearable Doppler ultrasound system. Based on internal jugular and carotid artery Doppler surrogates of CVP and SV, respectively, we placed hemodynamic assessments into quadrants (Qx) prior to preload augmentation: low CVP with normal SV (Q1), high CVP and normal SV (Q2), low CVP and low SV (Q3) and high CVP and low SV (Q4). The proportion of preload responsive and unresponsive assessments in each quadrant was calculated based on the maximal change in ccFT (ccFTΔ) during either a passive leg raise or rapid fluid challenge. Results: We analyzed 41 patients (68 hemodynamic assessments) between February and April 2021. The prevalence of each phenotype was: 15 (22%) in Q1, 8 (12%) in Q2, 39 (57%) in Q3, and 6 (9%) in Q4. Preload unresponsiveness rates were: Q1, 20%; Q2, 50%; Q3, 33%, and Q4, 67%. Interpretation: Even fluid naïve ED patients with sonographic estimates of low CVP have high rates of fluid unresponsiveness, making dynamic testing valuable to prevent ineffective IVF administration.


Asunto(s)
Arterias Carótidas , Fluidoterapia , Venas Yugulares , Ultrasonografía Doppler , Humanos , Proyectos Piloto , Masculino , Femenino , Fluidoterapia/métodos , Persona de Mediana Edad , Venas Yugulares/diagnóstico por imagen , Estudios Prospectivos , Arterias Carótidas/diagnóstico por imagen , Anciano , Resucitación/métodos , Presión Venosa Central/fisiología , Estudios Retrospectivos , Adulto , Volumen Sistólico/fisiología , Gasto Cardíaco/fisiología , Servicio de Urgencia en Hospital , Hemodinámica
2.
J Med Ultrasound ; 31(4): 309-313, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38264586

RESUMEN

Background: Doppler ultrasound of the common carotid artery is used to infer central hemodynamics. For example, change in the common carotid artery corrected flow time (ccFT) and velocity time integral (VTI) are proposed surrogates of changing stroke volume. However, conflicting data exist which may be due to inadequate beat sample size and measurement variability - both intrinsic to handheld systems. In this brief communication, we determined the correlation between changing ccFT and carotid VTI during progressively severe central blood volume loss and resuscitation. Methods: Measurements were obtained through a novel, wireless, wearable Doppler ultrasound system. Sixteen participants (ages of 18-40 years with no previous medical history) were studied across 25 lower body-negative pressure protocols. Relationships were assessed using repeated-measures correlation regression models. Results: In total, 33,110 cardiac cycles comprise this analysis; repeated-measures correlation showed a strong, linear relationship between ccFT and VTI. The strength of the ccFT-VTI relationship was dependent on the number of consecutively averaged cardiac cycles (R1 cycle = 0.70, R2 cycles = 0.74, and R10 cycles = 0.81). Conclusions: These results positively support future clinical investigations employing common carotid artery Doppler as a surrogate for central hemodynamics.

3.
Indian J Crit Care Med ; 26(3): 406, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35519920

RESUMEN

Kenny JES. Is the Carotid Artery a Window to the Left Ventricle? Indian J Crit Care Med 2022;26(3):406.

4.
J Cardiothorac Vasc Anesth ; 35(5): 1509-1515, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33597088

RESUMEN

In this Emerging Technology Review, a novel, wireless, wearable Doppler ultrasound patch is described as a tool for resuscitation. The device is designed, foremost, as a functional hemodynamic monitor-a simple, fast, and consistent method for measuring hemodynamic change with preload variation. More generally, functional hemodynamic monitoring is a paradigm that helps predict stroke volume response to additional intravenous volume. Because Doppler ultrasound of the left ventricular outflow tract noninvasively measures stroke volume in realtime, it increasingly is deployed for this purpose. Nevertheless, Doppler ultrasound in this manner is cumbersome, especially when repeat assessments are needed. Accordingly, peripheral arteries have been studied and various measures from the common carotid artery Doppler signal act as windows to the left ventricle. Yet, handheld Doppler ultrasound of a peripheral artery is susceptible to human measurement error and statistical limitations from inadequate beat sample size. Therefore, a wearable Doppler ultrasound capable of continuous assessment minimizes measurement inconsistencies and smooths inherent physiologic variation by sampling many more cardiac cycles. Reaffirming clinical studies, the ultrasound patch tracks immediate SV change with excellent accuracy in healthy volunteers when cardiac preload is altered by various maneuvers. The wearable ultrasound also follows jugular venous Doppler, which qualitatively trends right atrial pressure. With further clinical research and the application of artificial intelligence, the monitoring modalities with this new technology are manifold.


Asunto(s)
Monitorización Hemodinámica , Inteligencia Artificial , Hemodinámica , Humanos , Volumen Sistólico , Ultrasonografía Doppler
5.
Vet Anaesth Analg ; 47(1): 3-14, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31831334

RESUMEN

OBJECTIVE: Cardiovascular responses to hypovolemia and hypotension are depressed during general anesthesia. A considerable number of anesthetized and critically ill animals may not benefit hemodynamically from a fluid bolus; therefore, it is important to have measures for accurate prediction of fluid responsiveness. Static measures of preload, such as central venous pressure, do not provide accurate prediction of fluid responsiveness, whereas dynamic measures of cardiovascular function, obtained during positive pressure ventilation, are highly predictive. This review describes key physiological concepts behind heart-lung interactions during positive pressure ventilation, factors that can modify this relationship and provides the basis for a rational interpretation of the information obtained from dynamic measurements, with a focus on pulse pressure variation (PPV). DATABASE USED: PubMed. Search items used were: heart-lung interaction, positive pressure ventilation, pulse pressure variation, dynamic index of fluid therapy, goal-directed hemodynamic therapy, dogs, cats, pigs, horses and rabbits. CONCLUSIONS: The veterinary literature suggests that targeting specific PPV thresholds should guide fluid therapy in lieu of conventional assessments. Understanding the physiology of heart-lung interactions during intermittent positive pressure ventilation provides a rational basis for interpreting the literature on dynamic indices of fluid responsiveness, including PPV. Clinical trials are needed to evaluate whether goal-directed fluid therapy based on PPV results in improved outcomes in veterinary patient populations.


Asunto(s)
Anestesia General/veterinaria , Fluidoterapia/veterinaria , Respiración con Presión Positiva/veterinaria , Animales , Periodo Perioperatorio , Fenómenos Fisiológicos Respiratorios , Volumen Sistólico
18.
Front Med Technol ; 6: 1320810, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38333734

RESUMEN

The left ventricular outflow tract velocity time integral (LVOT VTI) is commonly used in the intensive care unit as a measure of stroke volume (SV) and how the SV changes in response to an intervention; therefore, the LVOT VTI is used to guide intravenous fluid management. Various peripheral Doppler surrogates are proposed to infer the LVOT VTI (e.g., measures from the common carotid artery). A recently-described, novel method of insonation has an excellent ability to detect change in the LVOT VTI. This approach raises important facets of Doppler flow and insonation error, as well as the general principles at play when using a peripheral artery to infer changes from the left ventricle. Relating the VTI of a peripheral artery to the LVOT VTI was recently described mathematically and may help clinicians think about the Doppler relationship between central and peripheral flow.

19.
Australas J Ultrasound Med ; 27(3): 193-196, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39328256

RESUMEN

Introduction: Ultrasonography as a guide for intravenous (IV) fluid therapy is increasingly accepted within the spheres of acute care. Initial investigations and protocols often focused on measures of arterial flow as an objective approach for personalising organ 'perfusion.' More recently, and with literature associating excessive IV fluid with adverse outcomes, venous ultrasound as a measure of organ 'congestion' is taking hold. Yet, arterial (i.e., 'perfusion') and venous (i.e., 'congestion') Doppler ultrasound measures are often performed separately and can be time-consuming, especially for novices. Methods: We report a case, wherein venous and arterial Doppler were simultaneously measured using a wireless, wearable ultrasound as a means to optimise flow without congestion. Results: Before IV volume expansion, the patient had Doppler measures consistent with low central venous pressure (CVP) and stroke volume (SV). Following IV volume expansion, venous Doppler remained the same; however, carotid corrected flow time (ccFT) increased significantly. Conclusion: A framework for venous-arterial Doppler enhanced resuscitation (VADER) can be used to guide IV volume in patients at risk for venous congestion.

20.
Acute Crit Care ; 39(1): 162-168, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38476069

RESUMEN

BACKGROUND: Using peripheral arteries to infer central hemodynamics is common among hemodynamic monitors. Doppler ultrasound of the common carotid artery has been used in this manner with conflicting results. We investigated the relationship between changing common carotid artery Doppler measures and stroke volume (SV), hypothesizing that more consecutively-averaged cardiac cycles would improve SV-carotid Doppler correlation. METHODS: Twenty-seven healthy volunteers were recruited and studied in a physiology laboratory. Carotid artery Doppler pulse was measured with a wearable, wireless ultrasound during central hypovolemia and resuscitation induced by a stepped lower body negative pressure protocol. The change in maximum velocity time integral (VTI) and corrected flow time of the carotid artery (ccFT) were compared with changing SV using repeated measures correlation. RESULTS: In total, 73,431 cardiac cycles were compared across 27 subjects. There was a strong linear correlation between changing SV and carotid Doppler measures during simulated hemorrhage (repeated-measures linear correlation [Rrm ]=0.91 for VTI; 0.88 for ccFT). This relationship improved with larger numbers of consecutively-averaged cardiac cycles. For ccFT, beyond four consecutively-averaged cardiac cycles the correlation coefficient remained strong (i.e., Rrm of at least 0.80). For VTI, the correlation coefficient with SV was strong for any number of averaged cardiac cycles. For both ccFT and VTI, Rrm remained stable around 25 consecutively-averaged cardiac cycles. CONCLUSIONS: There was a strong linear correlation between changing SV and carotid Doppler measures during central blood volume loss. The strength of this relationship was dependent upon the number of consecutively-averaged cardiac cycles.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA