RESUMEN
Laboratories are currently witnessing extraordinary demand globally for sampling devices, reagents, consumables, and diagnostic instruments needed for timely diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. To meet diagnostic needs as the pandemic grows, the U.S. Food and Drug Administration (FDA) recently granted several commercial SARS-CoV-2 tests Emergency Use Authorization (EUA), but manufacturer-independent evaluation data are scarce. We performed the first manufacturer-independent evaluation of the fully automated sample-to-result two-target test cobas 6800 SARS-CoV-2 (cobas) (Roche Molecular Systems, Branchburg, NJ), which received U.S. FDA EUA on 12 March 2020. The comparator was a standardized 3-h SARS-CoV-2 protocol, consisting of RNA extraction using an automated portable instrument, followed by a two-target reverse transcription real-time PCR (RT-PCR), which our laboratory has routinely used since January 2020 [V. M. Corman, O. Landt, M. Kaiser, R. Molenkamp, et al., Euro Surveill 25(3):pii=2000045, 2020, https://doi.org/10.2807/1560-7917.ES.2020.25.3.2000045]. cobas and the comparator showed overall agreement of 98.1% and a kappa value of 0.95 on an in-house validation panel consisting of 217 well-characterized retrospective samples. Immediate prospective head-to-head comparative evaluation followed on 502 samples, and the diagnostic approaches showed overall agreement of 99.6% and a kappa value of 0.98. A good correlation (r2 = 0.96) between cycle threshold values for SARS-CoV-2-specific targets obtained by cobas and the comparator was observed. Our results showed that cobas is a reliable assay for qualitative detection of SARS-CoV-2 in nasopharyngeal swab samples collected in the Universal Transport Medium System (UTM-RT) (Copan, Brescia, Italy). Under the extraordinary circumstances that laboratories are facing worldwide, a safe diagnostic platform switch is feasible in only 48 h and in the midst of the COVID-19 pandemic if carefully planned and executed.
Asunto(s)
Betacoronavirus , Técnicas de Laboratorio Clínico/métodos , Infecciones por Coronavirus/diagnóstico , Neumonía Viral/diagnóstico , Betacoronavirus/genética , COVID-19 , Prueba de COVID-19 , Vacunas contra la COVID-19 , Humanos , Pandemias , SARS-CoV-2 , Factores de TiempoRESUMEN
Flaviviruses are relevant animal and human pathogens of increasing importance worldwide. The similarities of the initial clinical symptoms and the serological cross-reactivity of viral structural antigens make a laboratory diagnosis of flavivirus infection problematic. The main aim of the present study was the comparative specificity and sensitivity analysis of the non-structural protein NS1 as an antigen to detect flavivirus antibodies in sera from exposed individuals. A strategy for the purification of native recombinant non-structural protein 1 of representative flaviviruses including tick-borne encephalitis, West Nile, Zika and dengue virus was developed. The immunological properties of the purified antigens were analyzed using sera of immunized mice and of infected individuals in comparison with standard commercial assays. Recombinant NS1 protein was confirmed as a valuable option for the detection of flavivirus antibodies with reduced cross-reactivity and high sensitivity offering additional advantages for the detection of vaccine breakthrough cases.