1.
J Nucl Med ; 46(6): 996-1004, 2005 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-15937311

RESUMEN

UNLABELLED: The 32-module quadHIDAC is a commercial, high-resolution animal PET scanner, based on gas multiwire proportional chambers. METHODS: Several scanner parameters that characterize the performance of the system were evaluated in this study, such as spatial resolution, absolute sensitivity, scatter, and count rate performance. The spatial resolution has been determined with filtered back-projected images of a point source. A line source, a mouse phantom, and a rat phantom have been used to characterize the count rate performance. The scatter fraction and photon absorption have been measured with a mouse scatter phantom. The absolute sensitivity has been determined using a line source with aluminum shields of different thickness. RESULTS: Spatial resolution (full width at half maximum) offers values of 1.08, 1.08, and 1.04 mm in the radial, tangential, and axial directions, respectively. The maximum count rate is 370 kcps for a line source of 19 MBq activity. Registration of scattered coincidences is caused primarily by photons scattering in the large coincidence detectors. For a mouse-sized object, only 5% of the measured coincidences scatter inside the animal, whereas 32% of the coincidences scatter inside the detectors. Photon attenuation within a mouse phantom was 22%. After scatter corrections, the absolute sensitivity of the system is 15.2 cps/kBq for a point source and 13.7 cps/kBq for a 7.8-cm-long line source. The peak noise equivalent count rates are 67 kcps@209 kBq/mL for the mouse phantom and 52 kcps@96 kBq/mL for the rat phantom. Finally, a comparison has been made with the microPET R4, a commercial scintillation crystal-based PET camera. CONCLUSION: The results confirm that the quadHIDAC PET scanner, with its large cylindric field of view (165-mm diameter, 280-mm axial length), is particularly suitable for imaging small animals such as mice or rats.


Asunto(s)
Interpretación de Imagen Asistida por Computador , Tomografía de Emisión de Positrones/instrumentación , Animales , Fluorodesoxiglucosa F18 , Ratones , Fantasmas de Imagen , Radiofármacos , Ratas , Recuento Corporal Total
2.
Eur J Nucl Med Mol Imaging ; 30(5): 737-47, 2003 May.
Artículo en Inglés | MEDLINE | ID: mdl-12536244

RESUMEN

The microPET R4 scanner is a dedicated positron emission tomograph (PET) for studies of rodents. A number of scanner parameters such as spatial resolution, sensitivity, scatter, and count rate performance were determined in this work, which showed that the microPET R4 is a suitable PET scanner for small animals like mice and rats. In the center of the field of view (FOV) a maximal sensitivity of 43.66 cps/kBq for a centered point source was calculated from a measurement with a germanium-68 line source within an energy widow of 250-750 keV. A spatial resolution of 1.85 mm full-width at half-maximum (FWHM) in the axial direction and 1.66 mm FWHM in the transaxial direction was measured in the center with a 1-mm-diameter sodium-22 point source. Within the inner 20 mm of the FOV the volumetric resolution is better than 15.6 micro l, corresponding to a linear resolution of less than 2.5 mm in all three dimensions. Images of a high-resolution phantom and from mice and rat studies illustrate the good performance of the scanner. A maximal noise equivalent count rate (NECR) was reached at 174 kcps for a mouse phantom and at 93 kcps for a rat phantom (energy window 250-750 keV). Scatter fractions were measured between 0.30 and 0.42 for an energy window of 250-750 keV and phantom diameters similar to mice and rats. A comparison with the microPET P4 model for primates illustrates the gain in sensitivity due to a smaller detector ring diameter but also the changes in NECR.


Asunto(s)
Encéfalo/diagnóstico por imagen , Análisis de Falla de Equipo , Tomografía Computarizada de Emisión/instrumentación , Tomografía Computarizada de Emisión/métodos , Animales , Gatos , Diseño de Equipo , Ratones , Miniaturización , Fantasmas de Imagen , Ratas , Reproducibilidad de los Resultados , Roedores , Dispersión de Radiación , Sensibilidad y Especificidad , Recuento Corporal Total/métodos