1.
J Appl Clin Med Phys ; 24(1): e13753, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-35998153

RESUMEN

High-energy accelerators are often used in oncological practice, but the information on the small-field dosimetry for the photon beams with nominal energy above 10 MV is limited. The goal of the present work was to determine the values of the output correction factor ( k Q clin , Q ref f clin , f ref $k_{{Q}_{{\rm{clin}}},{Q}_{{\rm{ref}}}}^{{f}_{{\rm{clin}}},{f}_{{\rm{ref}}}}$ ) for solid-state detectors (Diode E, PTW 60017; microDiamond, PTW 60019), EBT3 film, and ionization chambers (Semiflex, PTW 31010; Semiflex 3D, PTW 31021; PinPoint, PTW 31015; PinPoint 3D, PTW 31016) in the small fields formed by 10, 15, 18, and 20 MV photon beams. The output correction factors were calculated by Monte-Carlo method using EGSnrc toolkit for six field sizes (from 0.5 × 0.5 cm 2 $0.5 \times 0.5\ {\rm{cm}}^2$ to 10 × 10 cm 2 $10 \times 10\ {\rm{cm}}^2$ ) for isocentric and constant source-to-surface distance (SSD) techniques. The decrease in the field size led to an increase in k Q clin , Q ref f clin , f ref $k_{{Q}_{{\rm{clin}}},{Q}_{{\rm{ref}}}}^{{f}_{{\rm{clin}}},{f}_{{\rm{ref}}}}$ for ionization chambers, while for solid-state detectors and radiochromic film, k Q clin , Q ref f clin , f ref $k_{{Q}_{{\rm{clin}}},{Q}_{{\rm{ref}}}}^{{f}_{{\rm{clin}}},{f}_{{\rm{ref}}}}$ were less than unity at the smallest field size. A larger sensitive volume of ionization chamber corresponded to a stronger deviation of output correction factor from unity: 1.847 (125 mm3 PTW 31010) versus up to 1.183 (16 mm3 PTW 31016) at the smallest field of 10 MV beam. The calculated output correction factors were used to correct the output factors for PTW 60017, PTW 60019, and EBT3. The deviation of the corrected output factor from the results of Monte-Carlo simulation did not exceed 3% in the fields from 1.0 × 1.0 cm 2 $1.0 \times 1.0\ {\rm{cm}}^2$ to 4.0 × 4.0 cm 2 $4.0 \times 4.0\ {\rm{cm}}^2$ for 10 and 18 MV beams. Thus, Diode E, microDiamond, and EBT3 film can be recommended for small-field dosimetry of high-energy photons.


Asunto(s)
Fotones , Radiometría , Humanos , Radiometría/métodos , Simulación por Computador , Método de Montecarlo
2.
Int J Mol Sci ; 24(14)2023 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-37511123

RESUMEN

Optically active liquid-crystalline dispersions (LCD) of nucleic acids, obtained by polymer- and salt-induced (psi-) condensation, e.g., by mixing of aqueous saline solutions of low molecular weight DNA (≤106 Da) and polyethylene glycol (PEG), possess an outstanding circular dichroism (CD) signal (so-called psi-CD) and are of interest for sensor applications. Typically, such CD signals are observed in PEG content from ≈12.5% to ≈22%. However, in the literature, there are very conflicting data on the existence of psi-CD in DNA LCDs at a higher content of crowding polymer up to 30-40%. In the present work, we demonstrate that, in the range of PEG content in the system above ≈24%, optically polymorphic LCDs can be formed, characterized by both negative and positive psi-CD signals, as well as by ones rather slightly differing from the spectrum of isotropic DNA solution. Such a change in the CD signal is determined by the concentration of the stock solution of PEG used for the preparation of LCDs. We assume that various saturation of polymer chains with water molecules may affect the amount of active water, which in turn leads to a change in the hydration of DNA molecules and their transition from B-form to Z-form.


Asunto(s)
ADN , Polímeros , Polímeros/química , Conformación de Ácido Nucleico , ADN/química , Polietilenglicoles/química , Dicroismo Circular , Agua
3.
Int J Mol Sci ; 22(11)2021 Jun 02.
Artículo en Inglés | MEDLINE | ID: mdl-34199667

RESUMEN

Nanoparticles (NPs) with a high atomic number (Z) are promising radiosensitizers for cancer therapy. However, the dependence of their efficacy on irradiation conditions is still unclear. In the present work, 11 different metal and metal oxide NPs (from Cu (ZCu = 29) to Bi2O3 (ZBi = 83)) were studied in terms of their ability to enhance the absorbed dose in combination with 237 X-ray spectra generated at a 30-300 kVp voltage using various filtration systems and anode materials. Among the studied high-Z NP materials, gold was the absolute leader by a dose enhancement factor (DEF; up to 2.51), while HfO2 and Ta2O5 were the most versatile because of the largest high-DEF region in coordinates U (voltage) and Eeff (effective energy). Several impacts of the X-ray spectral composition have been noted, as follows: (1) there are radiation sources that correspond to extremely low DEFs for all of the studied NPs, (2) NPs with a lower Z in some cases can equal or overcome by the DEF value the high-Z NPs, and (3) the change in the X-ray spectrum caused by a beam passing through the matter can significantly affect the DEF. All of these findings indicate the important role of carefully planning radiation exposure in the presence of high-Z NPs.


Asunto(s)
Cobre/uso terapéutico , Nanopartículas del Metal/uso terapéutico , Neoplasias/radioterapia , Fármacos Sensibilizantes a Radiaciones/uso terapéutico , Bismuto/química , Bismuto/uso terapéutico , Cobre/química , Relación Dosis-Respuesta a Droga , Humanos , Nanopartículas del Metal/química , Método de Montecarlo , Neoplasias/tratamiento farmacológico , Neoplasias/patología , Óxidos/química , Óxidos/uso terapéutico , Fármacos Sensibilizantes a Radiaciones/química , Dosificación Radioterapéutica
4.
Nanomaterials (Basel) ; 10(5)2020 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-32429500

RESUMEN

Gold nanoparticles (GNPs) emerged as promising antitumor radiosensitizers. However, the complex dependence of GNPs radiosensitization on the irradiation conditions remains unclear. In the present study, we investigated the impacts of the dose rate and photon energy on damage of the pBR322 plasmid DNA exposed to X-rays in the presence of 12 nm, 15 nm, 21 nm, and 26 nm GNPs. The greatest radiosensitization was observed for 26 nm GNPs. The sensitizer enhancement ratio (SER) 2.74 ± 0.61 was observed at 200 kVp with 2.4 mg/mL GNPs. Reduction of X-ray tube voltage to 150 and 100 kVp led to a smaller effect. We demonstrate for the first time that the change of the dose rate differentially influences on radiosensitization by GNPs of various sizes. For 12 nm, an increase in the dose rate from 0.2 to 2.1 Gy/min led to a ~1.13-fold increase in radiosensitization. No differences in the effect of 15 nm GNPs was found within the 0.85-2.1 Gy/min range. For 21 nm and 26 nm GNPs, an enhanced radiosensitization was observed along with the decreased dose rate from 2.1 to 0.2 Gy/min. Thus, GNPs are an effective tool for increasing the efficacy of orthovoltage X-ray exposure. However, careful selection of irradiation conditions is a key prerequisite for optimal radiosensitization efficacy.