Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Medicina (Kaunas) ; 58(9)2022 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-36143945

RESUMEN

Background and Objectives: Clinical decision support systems are advocated to improve the quality and efficiency in healthcare. However, before implementation, validation of these systems needs to be performed. In this evaluation we tested our hypothesis that a computerized clinical decision support system can calculate the CHA2DS2-VASc score just as well compared to manual calculation, or even better and more efficiently than manual calculation in patients with atrial rhythm disturbances. Materials and Methods: In n = 224 patents, we calculated the total CHA2DS2-VASc score manually and by an automated clinical decision support system. We compared the automated clinical decision support system with manually calculation by physicians. Results: The interclass correlation between the automated clinical decision support system and manual calculation showed was 0.859 (0.611 and 0.931 95%-CI). Bland-Altman plot and linear regression analysis shows us a bias of -0.79 with limit of agreement (95%-CI) between 1.37 and -2.95 of the mean between our 2 measurements. The Cohen's kappa was 0.42. Retrospective analysis showed more human errors than algorithmic errors. Time it took to calculate the CHA2DS2-VASc score was 11 s per patient in the automated clinical decision support system compared to 48 s per patient with the physician. Conclusions: Our automated clinical decision support system is at least as good as manual calculation, may be more accurate and is more time efficient.


Asunto(s)
Fibrilación Atrial , Sistemas de Apoyo a Decisiones Clínicas , Accidente Cerebrovascular , Técnicas de Apoyo para la Decisión , Humanos , Valor Predictivo de las Pruebas , Mejoramiento de la Calidad , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Accidente Cerebrovascular/prevención & control
2.
Sensors (Basel) ; 21(16)2021 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-34451035

RESUMEN

In standard critical care practice, cuff sphygmomanometry is widely used for intermittent blood pressure (BP) measurements. However, cuff devices offer ample possibility of modulating blood flow and pulse propagation along the artery. We explore underutilized arrangements of sensors involving cuff devices which could be of use in critical care to reveal additional information on compensatory mechanisms. In our previous work, we analyzed the response of the vasculature to occlusion perturbations by means of observations obtained non-invasively. In this study, our aim is to (1) acquire additional insights by means of invasive measurements and (2) based on these insights, further develop cuff-based measurement strategies. Invasive BP experimental data is collected downstream from the cuff in two patients monitored in the OR. It is found that highly dynamic processes occur in the distal arm during cuff inflation. Mean arterial pressure increases in the distal artery by 20 mmHg, leading to a decrease in pulse transit time by 20 ms. Previous characterizations neglected such distal vasculature effects. A model is developed to reproduce the observed behaviors and to provide a possible explanation of the factors that influence the distal arm mechanisms. We apply the new findings to further develop measurement strategies aimed at acquiring information on pulse arrival time vs. BP calibration, artery compliance, peripheral resistance, artery-vein interaction.


Asunto(s)
Determinación de la Presión Sanguínea , Análisis de la Onda del Pulso , Arterias , Presión Sanguínea , Frecuencia Cardíaca , Humanos
3.
Eur Heart J ; 39(28): 2646-2655, 2018 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-29617762

RESUMEN

Aims: Echocardiography and tomographic imaging have documented dynamic changes in aortic stenosis (AS) geometry and severity during both the cardiac cycle and stress-induced increases in cardiac output. However, corresponding pressure gradient vs. flow relationships have not been described. Methods and results: We recruited 16 routine transcatheter aortic valve implantations (TAVI's) for graded dobutamine infusions both before and after implantation; 0.014″ pressure wires in the aorta and left ventricle (LV) continuously measured the transvalvular pressure gradient (ΔP) while a pulmonary artery catheter regularly assessed cardiac output by thermodilution. Before TAVI, ΔP did not display a consistent relationship with transvalvular flow (Q). Neither linear resistor (median R2 0.16) nor quadratic orifice (median R2 < 0.01) models at rest predicted stress observations; the severely stenotic valve behaved like a combination. The unitless ratio of aortic to left ventricular pressures during systolic ejection under stress conditions correlated best with post-TAVI flow improvement. After TAVI, a highly linear relationship (median R2 0.96) indicated a valid valve resistance. Conclusion: Pressure loss vs. flow curves offer a fundamental fluid dynamic synthesis for describing aortic valve pathophysiology. Severe AS does not consistently behave like an orifice (as suggested by Gorlin) or a resistor, whereas TAVI devices behave like a pure resistor. During peak dobutamine, the ratio of aortic to left ventricular pressures during systolic ejection provides a 'fractional flow reserve' of the aortic valve that closely approximates the complex, changing fluid dynamics. Because resting assessment cannot reliably predict stress haemodynamics, 'valvular fractional flow' warrants study to explain exertional symptoms in patients with only moderate AS at rest.


Asunto(s)
Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/fisiología , Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Presión Sanguínea , Femenino , Humanos , Masculino , Flujo Sanguíneo Regional , Índice de Severidad de la Enfermedad , Factores de Tiempo
4.
J Clin Monit Comput ; 33(6): 1023-1031, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30661195

RESUMEN

Accumulating evidence shows that ultrasound (US) guidance improves effectiveness and safety of central venous catheter (CVC) placement. Several international guidelines therefore recommend the use of US for placement of CVCs. However, surveys show that the landmark-based technique is still widely used, while the percentage of physicians using US is increasing less than expected. The goal of this study was to investigate current practice for central venous catheterization in anaesthesiology and intensive care in the Netherlands, identify barriers for further implementation of US guidance and to evaluate whether personality traits are associated with the choice of technique. We conducted a web-based national survey, distributed among members of the Dutch societies of anaesthesiology (NVA) and intensive care (NVIC). The survey contained questions regarding physician and hospital characteristics, frequency of US use and reasons for use or non-use, as well as the NEO-FFI-3, a validated, translated questionnaire to characterize personality traits according to the 'Big Five' concept. Response rate was 22% (506/2291), of which 400 had also the personality questionnaire complete. Ultrasound guidance was used always or almost always in 68%; barriers for US use were working in a non-academic non-teaching hospital, providing cardiac anaesthesia and more years of physician experience. Reasons for not using US were perceived lack of benefit, increased procedure time, lack of US equipment and fear of loss of landmark technique skills. 13% of respondents had never experienced a complication during CVC placement, and 67% knew of a complication occurring the past year at their department. Ultrasound was thought not to be able to prevent the complication in half of these cases. Of the personality traits, only neuroticism and extraversion showed a minor positive association with US guidance. A majority of anaesthesiologists and intensivists uses US guidance for CVC placement, but a significant proportion of physicians still prefers the landmark technique. Most arguments from respondents against US guidance can be challenged. Personality traits most likely do not play a major role in the acceptance of US guidance for central venous catheterization. A potential intervention to increase US use could be formalizing local hospital policies mandating compliance with US guidance. Future research can perhaps focus on cognitive biases that currently limit more widespread use of US guidance.


Asunto(s)
Anestesiología/normas , Cateterismo Venoso Central/tendencias , Cuidados Críticos/normas , Personalidad , Pautas de la Práctica en Medicina , Ultrasonografía Intervencional/tendencias , Anestesiólogos , Anestesiología/tendencias , Cateterismo Venoso Central/normas , Catéteres Venosos Centrales , Cognición , Cuidados Críticos/tendencias , Femenino , Humanos , Internacionalidad , Internet , Masculino , Países Bajos , Guías de Práctica Clínica como Asunto , Análisis de Regresión , Resultado del Tratamiento , Ultrasonografía Intervencional/normas
5.
Echocardiography ; 34(8): 1138-1145, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28600804

RESUMEN

INTRODUCTION: Pulmonary transit time (PTT) assessed with contrast-enhanced ultrasound (CEUS) is a novel tool to evaluate cardiac function. PTT represents the time for a bolus of contrast to pass from the right to the left ventricle, measured according to the indicator dilution principles using CEUS. We investigated the hypothesis that PTT is a measure of general cardiac performance in patient populations eligible for cardiac resynchronization therapy (CRT). METHODS: The study population consisted of heart failure patients referred for CRT with NYHA class II-IV, left ventricular ejection fraction (LVEF)≤35% and QRS≥120 ms. CEUS, ECG, and blood were analyzed, and participants completed a quality of life questionnaire at baseline and 3 months after CRT implantation. Normalized PTT (nPTT) was calculated to compensate for the heart rate. Correlations were assessed with Pearson's or Spearman's coefficients and stratified for rhythm and NYHA class. RESULTS: The study population consisted of 94 patients (67 men) with a mean age of 70±8.9 years. (n)PTT was significantly correlated with left ventricular parameters (rs =-.487, P<.001), right ventricular parameters (r=-.282, P=.004), N-terminal pro-B-type natriuretic peptide (NT-proBNP) (rs =.475, P<.001), and quality of life (rs =.364, P<.001). Stronger significant correlations were found in patients in sinus rhythm. CONCLUSION: CEUS-derived PTT and nPTT correlate to a fair degree with measures of systolic and diastolic function, NT-pro-BNP, and quality of life. As CEUS-derived PTT can be obtained easily, noninvasively and at the bedside, it is a promising future measure of general cardiac performance.


Asunto(s)
Volumen Sanguíneo/fisiología , Terapia de Resincronización Cardíaca/métodos , Ecocardiografía/métodos , Insuficiencia Cardíaca/fisiopatología , Ventrículos Cardíacos/fisiopatología , Volumen Sistólico/fisiología , Función Ventricular Izquierda/fisiología , Anciano , Determinación del Volumen Sanguíneo , Medios de Contraste/farmacología , Diástole , Femenino , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/fisiopatología , Insuficiencia Cardíaca/terapia , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Pronóstico , Reproducibilidad de los Resultados , Sístole
6.
Cardiovasc Ultrasound ; 14: 1, 2016 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-26729228

RESUMEN

BACKGROUND: The aim of this study is to investigate the inter and intra-rater reliability, repeatability, and reproducibility of pulmonary transit time (PTT) measurement in patients using contrast enhanced ultrasound (CEUS), as an indirect measure of preload and left ventricular function. METHODS: Mean transit times (MTT) were measured by drawing a region of interest (ROI) in right and left cardiac ventricle in the CEUS loops. Acoustic intensity dilution curves were obtained from the ROIs. MTTs were calculated by applying model-based fitting on the dilution curves. PTT was calculated as the difference of the MTTs. Eight raters with different levels of experience measured the PTT (time moment 1) and repeated the measurement within a week (time moment 2). Reliability and agreement were assessed using intra-class correlations (ICC) and Bland-Altman analysis. Repeatability was tested by estimating the variance of means (ANOVA) of three injections in each patient at different doses. Reproducibility was tested by the ICC of the two time moments. RESULTS: Fifteen patients with heart failure were included. The mean PTT was 11.8 ± 3.1 s at time moment 1 and 11.7 ± 2.9 s at time moment 2. The inter-rater reliability for PTT was excellent (ICC = 0.94). The intra-rater reliability per rater was between 0.81-0.99. Bland-Altman analysis revealed a bias of 0.10 s within the rater groups. Reproducibility for PTT showed an ICC = 0.94 between the two time moments. ANOVA showed no significant difference between the means of the three different doses F = 0.048 (P = 0.95). The mean and standard deviation for PTT estimates at three different doses was 11.6 ± 3.3 s. CONCLUSIONS: PTT estimation using CEUS shows a high inter- and intra-rater reliability, repeatability at three different doses, and reproducibility by ROI drawing. This makes the minimally invasive PTT measurement using contrast echocardiography ready for clinical evaluation in patients with heart failure and for preload estimation.


Asunto(s)
Volumen Sanguíneo , Ecocardiografía/métodos , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/fisiopatología , Fosfolípidos/farmacocinética , Análisis de la Onda del Pulso/métodos , Hexafluoruro de Azufre/farmacocinética , Anciano , Determinación del Volumen Sanguíneo/métodos , Medios de Contraste/farmacocinética , Femenino , Humanos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
8.
Cardiovasc Ultrasound ; 11: 36, 2013 Oct 17.
Artículo en Inglés | MEDLINE | ID: mdl-24134671

RESUMEN

BACKGROUND: Contrast-enhanced ultrasound (CEUS) has recently been proposed as a minimally- invasive, alternative method for blood volume measurement. This study aims at comparing the accuracy of CEUS and the classical thermodilution techniques for volume assessment in an in-vitro set-up. METHODS: The in-vitro set-up consisted of a variable network between an inflow and outflow tube and a roller pump. The inflow and outflow tubes were insonified with an ultrasound array transducer and a thermistor was placed in each tube. Indicator dilution curves were made by injecting indicator which consisted of an ultrasound-contrast-agent diluted in ice-cold saline. Both acoustic intensity- and thermo-dilution curves were used to calculate the indicator mean transit time between the inflow and outflow tube. The volumes were derived by multiplying the estimated mean transit time by the flow rate. We compared the volumes measured by CEUS with the true volumes of the variable network and those measured by thermodilution by Bland-Altman and intraclass-correlation analysis. RESULTS: The measurements by CEUS and thermodilution showed a very strong correlation (rs = 0.94) with a modest volume underestimation by CEUS of -40 ± 28 mL and an overestimation of 84 ± 62 mL by thermodilution compared with the true volumes. Both CEUS and thermodilution showed a high statistically significant correlation with the true volume (rs = 0.97 (95% CI, 0.95 - 0.98; P<0.0001) and rs = 0.96 (95% CI, 0.94 - 0.98; P<0.0001, respectively). CONCLUSIONS: CEUS volume estimation provides a strong correlation with both the true volumes in-vitro and volume estimation by thermodilution. It may therefore represent an interesting alternative to the standard, invasive thermodilution technique.


Asunto(s)
Determinación del Volumen Sanguíneo/métodos , Ecocardiografía Transesofágica/instrumentación , Ecocardiografía Transesofágica/métodos , Fantasmas de Imagen , Fosfolípidos , Hexafluoruro de Azufre , Volumen Sanguíneo/fisiología , Medios de Contraste/administración & dosificación , Diseño de Equipo , Humanos , Imagenología Tridimensional/instrumentación , Imagenología Tridimensional/métodos , Fosfolípidos/administración & dosificación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Hexafluoruro de Azufre/administración & dosificación , Termodilución
9.
PLoS One ; 18(8): e0286818, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37535542

RESUMEN

BACKGROUND AND OBJECTIVES: Currently, no evidence-based criteria exist for decision making in the post anesthesia care unit (PACU). This could be valuable for the allocation of postoperative patients to the appropriate level of care and beneficial for patient outcomes such as unanticipated intensive care unit (ICU) admissions. The aim is to assess whether the inclusion of intra- and postoperative factors improves the prediction of postoperative patient deterioration and unanticipated ICU admissions. METHODS: A retrospective observational cohort study was performed between January 2013 and December 2017 in a tertiary Dutch hospital. All patients undergoing surgery in the study period were selected. Cardiothoracic surgeries, obstetric surgeries, catheterization lab procedures, electroconvulsive therapy, day care procedures, intravenous line interventions and patients under the age of 18 years were excluded. The primary outcome was unanticipated ICU admission. RESULTS: An unanticipated ICU admission complicated the recovery of 223 (0.9%) patients. These patients had higher hospital mortality rates (13.9% versus 0.2%, p<0.001). Multivariable analysis resulted in predictors of unanticipated ICU admissions consisting of age, body mass index, general anesthesia in combination with epidural anesthesia, preoperative score, diabetes, administration of vasopressors, erythrocytes, duration of surgery and post anesthesia care unit stay, and vital parameters such as heart rate and oxygen saturation. The receiver operating characteristic curve of this model resulted in an area under the curve of 0.86 (95% CI 0.83-0.88). CONCLUSIONS: The prediction of unanticipated ICU admissions from electronic medical record data improved when the intra- and early postoperative factors were combined with preoperative patient factors. This emphasizes the need for clinical decision support tools in post anesthesia care units with regard to postoperative patient allocation.


Asunto(s)
Hospitalización , Unidades de Cuidados Intensivos , Femenino , Embarazo , Humanos , Adolescente , Estudios Retrospectivos , Factores de Riesgo , Índice de Masa Corporal , Admisión del Paciente
10.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 2898-2901, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-36085836

RESUMEN

Blood pressure (BP) is a key parameter in critical care and in cardiovascular disease management. BP is typically measured via cuff-based oscillometry. This method is highly inaccurate in hypo- and hypertensive patients. Improvements are difficult to achieve because oscillometry is not yet fully understood; many assumptions and uncertainties exist in models describing the process by which arterial pulsations become expressed within the cuff signal. As a result, it is also difficult to estimate other parameters via the cuff such as arterial stiffness, cardiac output and pulse wave velocity (PWV)-BP calibration. Many research modalities have been employed to study oscillometry (ultrasound, computer simulations, ex-vivo studies, measurement of PWV, mechanical analysis). However, uncertainties remain; additional investigation modalities are needed. In this study, we explore the extent to which MRI can help investigate oscillometric assumptions. Four healthy volunteers underwent a number of MRI scans of the upper arm during cuff inflation. It is found that MRI provides a novel perspective over oscillometry; the artery, surrounding tissue, veins and the cuff can be simultaneously observed along the entire length of the upper arm. Several existing assumptions are challenged: tissue compression is not isotropic, arterial transmural pressure is not uniform along the length of the cuff and propagation of arterial pulsations through tissue is likely impacted by patient-specific characteristics (vasculature position and tissue composition). Clinical Relevance- The cuff interaction with the vasculature is extremely complex; existing models are oversimplified. MRI is a valuable tool for further development of cuff-based physiological measurements.


Asunto(s)
Técnicas de Diagnóstico Cardiovascular , Análisis de la Onda del Pulso , Humanos , Imagen por Resonancia Magnética , Oscilometría , Registros
12.
PLoS One ; 16(5): e0252166, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34029356

RESUMEN

BACKGROUND: Intravenous cannulation is usually the first procedure performed in modern healthcare, although establishing peripheral intravenous access is challenging in some patients. The impact of the ratio between venous diameter and the size of the inserted catheter (catheter to vein ratio, CVR) on the first attempt success rate can be of added value in clinical. This study tries to give insight into the consideration that must be made when selecting the target vein and the type of catheter, and proved the null hypothesis that an optimal CVR would not be associated with increased first attempt cannulation success. METHODS: This was a post-hoc analyses on adult patients admitted for peripheral intravenous cannulation. Intravenous cannulation was performed according to practice guidelines, by applying the traditional landmark approach. The CVR was calculated afterwards for each individual patient by dividing the external diameter of the inserted catheter by the diameter of the target vein, which was multiplied by 100%. RESULTS: In total, 610 patients were included. The median CVR was 0.39 (0.15) in patients with a successful first attempt, whereas patients with an unsuccessful first attempt had a median CVR of 0.55 (0.20) (P<0.001). The optimal cut-off point of the CVR was 0.41. First attempt cannulation was successful in 92% of patients with a CVR<0.41, whereas as those with a CVR>0.41 had a first attempt success rate of 65% (P<0.001). CONCLUSION: This first introduction of the CVR in relation to cannulation success should be further investigated. Although, measuring the venous diameter or detection of a vein with a specific diameter prior to cannulation may increase first attempt cannulation success.


Asunto(s)
Cateterismo Periférico/métodos , Catéteres , Venas , Adulto , Cateterismo Venoso Central/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factores de Riesgo
13.
JMIR Cardio ; 5(2): e27765, 2021 Nov 04.
Artículo en Inglés | MEDLINE | ID: mdl-34734834

RESUMEN

BACKGROUND: Measurement of heart rate (HR) through an unobtrusive, wrist-worn optical HR monitor (OHRM) could enable earlier recognition of patient deterioration in low acuity settings and enable timely intervention. OBJECTIVE: The goal of this study was to assess the agreement between the HR extracted from the OHRM and the gold standard 5-lead electrocardiogram (ECG) connected to a patient monitor during surgery and in the recovery period. METHODS: In patients undergoing surgery requiring anesthesia, the HR reported by the patient monitor's ECG module was recorded and stored simultaneously with the photopletysmography (PPG) from the OHRM attached to the patient's wrist. The agreement between the HR reported by the patient's monitor and the HR extracted from the OHRM's PPG signal was assessed using Bland-Altman analysis during the surgical and recovery phase. RESULTS: A total of 271.8 hours of data in 99 patients was recorded simultaneously by the OHRM and patient monitor. The median coverage was 86% (IQR 65%-95%) and did not differ significantly between surgery and recovery (Wilcoxon paired difference test P=.17). Agreement analysis showed the limits of agreement (LoA) of the difference between the OHRM and the ECG HR were within the range of 5 beats per minute (bpm). The mean bias was -0.14 bpm (LoA between -3.08 bpm and 2.79 bpm) and -0.19% (LoA between -5 bpm to 5 bpm) for the PPG- measured HR compared to the ECG-measured HR during surgery; during recovery, it was -0.11 bpm (LoA between -2.79 bpm and 2.59 bpm) and -0.15% (LoA between -3.92% and 3.64%). CONCLUSIONS: This study shows that an OHRM equipped with a PPG sensor can measure HR within the ECG reference standard of -5 bpm to 5 bpm or -10% to 10% in the perioperative setting when the PPG signal is of sufficient quality. This implies that an OHRM can be considered clinically acceptable for HR monitoring in low acuity hospitalized patients.

14.
JPEN J Parenter Enteral Nutr ; 45(3): 625-632, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-32384187

RESUMEN

BACKGROUND: Administering medication through an enteral feeding tube (FT) is a frequent cause of errors resulting in increased morbidity and cost. Studies on interventions to prevent these errors in hospitalized patients, however, are limited. OBJECTIVE: The objective was to study the effect of a clinical decision support system (CDSS)-assisted pharmacy intervention on the incidence of FT-related medication errors (FTRMEs) in hospitalized patients. METHODS: A pre-post intervention study was conducted between October 2014 and May 2015 in Catharina Hospital, the Netherlands. Patients who were admitted to the wards of bowel and liver disease, oncology, or neurology; using oral medication; and had an enteral FT were included. Preintervention patients were given care as usual. The intervention consisted of implementing a CDSS-assisted pharmacy check while also implementing standard operating procedures and educating personnel. An FTRME was defined as the administration of inappropriate medication through an enteral FT. The incidence was expressed as the number of FTRMEs per medication administration. Multivariate Poisson regression was used to calculate the incidence ratio (IR) comparing both phases. RESULTS: Eighty-one patients were included, 38 during preintervention and 43 during the intervention phase. Incidence of FTRMEs in the preintervention phase was 0.15 (95% CI, 0.07-0.23) vs 0.02 (95% CI, 0.00-0.04) in the intervention phase, resulting in an adjusted IR of 0.13 (95% CI, 0.10-0.18). DISCUSSION: Incidence of FTRMEs, as well as the IR, is comparable to previous studies. CONCLUSION: The intervention resulted in a substantial reduction in the incidence of FTRMEs.


Asunto(s)
Sistemas de Apoyo a Decisiones Clínicas , Farmacia , Nutrición Enteral , Humanos , Errores de Medicación/prevención & control , Países Bajos
15.
J Clin Med ; 8(2)2019 Jan 26.
Artículo en Inglés | MEDLINE | ID: mdl-30691137

RESUMEN

Peripheral intravenous cannulation is the most common invasive hospital procedure but is associated with a high failure rate. This study aimed to improve the A-DIVA scale (Adult Difficult Intra Venous Access Scale) by external validation, to predict the likelihood of difficult intravenous access in adults. This multicenter study was carried out throughout five hospitals in the Netherlands. Adult participants were included, regardless of their indication for intravenous access, demographics, and medical history. The main outcome variable was defined as failed peripheral intravenous cannulation on the first attempt. A total of 3587 participants was included in this study. The first attempt success rate was 81%. Finally, five variables were included in the prediction model: a history of difficult intravenous cannulation, a difficult intravenous access as expected by the practitioner, the inability to detect a dilated vein by palpating and/or visualizing the extremity, and a diameter of the selected vein less than 3 millimeters. Based on a participant's individual score on the A-DIVA scale, they were classified into either a low, moderate, or high-risk group. A higher score on the A-DIVA scale indicates a higher risk of difficult intravenous access. The five-variable additive A-DIVA scale is a reliable and generalizable predictive scale to identify patients at risk of difficult intravenous access.

16.
Eur J Echocardiogr ; 9(4): 483-8, 2008 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-17826355

RESUMEN

AIM: The influence of location and extent of transmural scar and its relation with dyssynchrony in cardiac resynchronization therapy (CRT) was investigated as posterolateral scar tissue has been invoked as a cause of non-response to CRT. METHODS AND RESULTS: Fifty-seven patients eligible for CRT were assessed for transmural scar with gadolinium-enhanced MRI and for left ventricular (LV) dyssynchrony with tissue Doppler. After implant, both atrioventricular and interventricular pacing intervals were optimized. LV reverse remodeling was defined as >/=10% decrease in LV end-systolic volume after 3 months. Sixteen patients had transmural scar in the posterolateral (PL) area (LV lead location), 14 at a remote site (non-PL) and 27 patients had no scar. LV reverse remodeling was observed in respectively 25%, 64% and 89% (P = 0.0001). Univariate analyses showed a relation with LV dyssynchrony (P = 0.004) and with absence of PL scar (P = 0.04) but not with QRS duration and the extent of LV scar tissue. In multivariate analysis, only LV dyssynchrony (OR: 19.62; 95% CI: 2.5-151.9; P = 0.004) independently predicted LV reverse remodeling. CONCLUSION: In this study LV dyssynchrony remains the most important determinant of response to CRT, even in the presence of posterolateral scar provided atrioventricular and interventricular pacing intervals are optimized.


Asunto(s)
Estimulación Cardíaca Artificial , Infarto del Miocardio/terapia , Disfunción Ventricular Izquierda/terapia , Remodelación Ventricular , Anciano , Cicatriz , Ecocardiografía Doppler , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Infarto del Miocardio/complicaciones , Infarto del Miocardio/diagnóstico , Disfunción Ventricular Izquierda/diagnóstico , Disfunción Ventricular Izquierda/etiología
17.
IEEE J Biomed Health Inform ; 22(2): 311-317, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-28922133

RESUMEN

Clinical pathways (CPs) are popular healthcare management tools to standardize care and ensure quality. Analyzing CP compliance levels and variances is known to be useful for training and CP redesign purposes. Flexible semantics of the business process model and notation (BPMN) language has been shown to be useful for the modeling and analysis of complex protocols. However, in practical cases one may want to exploit that CPs often have the form of task-time matrices. This paper presents a new method parsing complex BPMN models and aligning traces to the models heuristically. A case study on variance analysis is undertaken, where a CP from the practice and two large sets of patients data from an electronic medical record (EMR) database are used. The results demonstrate that automated variance analysis between BPMN task-time models and real-life EMR data are feasible, whereas that was not the case for the existing analysis techniques. We also provide meaningful insights for further improvement.


Asunto(s)
Vías Clínicas , Registros Electrónicos de Salud , Informática Médica , Minería de Datos , Toma de Decisiones Asistida por Computador , Humanos , Semántica
18.
Int J Comput Assist Radiol Surg ; 13(9): 1321-1333, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29855770

RESUMEN

PURPOSE: During needle interventions, successful automated detection of the needle immediately after insertion is necessary to allow the physician identify and correct any misalignment of the needle and the target at early stages, which reduces needle passes and improves health outcomes. METHODS: We present a novel approach to localize partially inserted needles in 3D ultrasound volume with high precision using convolutional neural networks. We propose two methods based on patch classification and semantic segmentation of the needle from orthogonal 2D cross-sections extracted from the volume. For patch classification, each voxel is classified from locally extracted raw data of three orthogonal planes centered on it. We propose a bootstrap resampling approach to enhance the training in our highly imbalanced data. For semantic segmentation, parts of a needle are detected in cross-sections perpendicular to the lateral and elevational axes. We propose to exploit the structural information in the data with a novel thick-slice processing approach for efficient modeling of the context. RESULTS: Our introduced methods successfully detect 17 and 22 G needles with a single trained network, showing a robust generalized approach. Extensive ex-vivo evaluations on datasets of chicken breast and porcine leg show 80 and 84% F1-scores, respectively. Furthermore, very short needles are detected with tip localization errors of less than 0.7 mm for lengths of only 5 and 10 mm at 0.2 and 0.36 mm voxel sizes, respectively. CONCLUSION: Our method is able to accurately detect even very short needles, ensuring that the needle and its tip are maximally visible in the visualized plane during the entire intervention, thereby eliminating the need for advanced bi-manual coordination of the needle and transducer.


Asunto(s)
Imagenología Tridimensional/métodos , Músculo Esquelético/diagnóstico por imagen , Agujas , Redes Neurales de la Computación , Fantasmas de Imagen , Semántica , Animales , Pollos , Modelos Animales , Porcinos , Transductores
19.
Am J Cardiol ; 99(1): 75-8, 2007 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-17196466

RESUMEN

Isovolumic times (IVTs) comprise a determinant of exercise capacity in cardiomyopathy. We postulated that an increase in exercise capacity after cardiac resynchronization therapy (CRT) might be related to a more efficient cardiac cycle due to decreasing IVTs and increased filling times. According to standard selection criteria, a CRT device was implanted in 52 patients (37 men; 69 +/- 8 years) with a QRS duration of 174 +/- 30 ms. The etiology was ischemic in 22 and idiopathic in 30 patients. A 6-minute walking test (MWT) and echocardiographic Doppler were performed before and 3 and 6 months after CRT. Timing cycles were obtained with echocardiographic Doppler. An improvement in MWT by >15% (responders) after 6 months of CRT was observed in 46% of patients. The MWT was moderately correlated with baseline time intervals (IVT r = -0.44, filling time r = 0.52), but not to baseline left ventricular ejection fraction (r = -0.06). However, change in the MWT after 3 and 6 months was best related to changes in IVT (r = -0.66 and -0.68, respectively). Receiver-operating characteristic curve analysis of baseline IVT showed that an IVT >29% predicted exercise response with a positive predictive value of 89% and a negative predictive value of 77%. In conclusion, improvement in exercise tolerance after CRT is associated with a decrease in prolonged IVT. Baseline IVT might be used as an adjunctive parameter for selecting symptomatic responders to CRT.


Asunto(s)
Estimulación Cardíaca Artificial , Cardiomiopatías/terapia , Tolerancia al Ejercicio , Volumen Sistólico , Anciano , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/fisiopatología , Ecocardiografía Doppler , Electrocardiografía , Sistema de Conducción Cardíaco , Humanos , Masculino , Valor Predictivo de las Pruebas , Curva ROC , Sensibilidad y Especificidad
20.
Am J Cardiol ; 99(7): 966-9, 2007 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-17398193

RESUMEN

A multiphasic septal motion and typical septal-to-lateral apical shuffle of the left ventricle can be observed echocardiographically in some patients with left branch bundle block. The relation of both with left ventricular (LV) dyssynchrony according to tissue Doppler and LV reverse remodeling after cardiac resynchronization therapy was investigated. Fifty-three patients (37 men; age 68+/-8 years) with ischemic (n=26) or idiopathic (n=27) cardiomyopathy, baseline QRS duration 171+/-30 ms, LV ejection fraction 21+/-7%, and LV end-diastolic volume 257+/-91 ml were studied. LV dyssynchrony using tissue Doppler was considered present if the SD of the interval between QRS and onset of systolic velocity of 6 basal LV segments was >20 ms. Shuffle was evaluated visually independently by 5 cardiologists and considered present if observed in>or=1 view. LV reverse remodeling, defined as LV end-systolic volume decrease>or=10%, was observed in 37 patients (70%) after 3 months of CRT. Sensitivity and specificity of either shuffle or multiphasic septal motion for all 5 observers (range 90% to 97% and 67% to 83%, respectively) were found to predict LV dyssynchrony. To predict LV reverse remodeling, sensitivity and specificity from 87% to 92% and 69% to 81% were observed, respectively. In conclusion, the qualitative observation of a typical shuffle or multiphasic septal motion predicts LV dyssynchrony and LV reverse remodeling adequately.


Asunto(s)
Estimulación Cardíaca Artificial , Tabiques Cardíacos/fisiopatología , Remodelación Ventricular , Anciano , Bloqueo de Rama/fisiopatología , Bloqueo de Rama/terapia , Cardiomiopatía Dilatada/fisiopatología , Cardiomiopatía Dilatada/terapia , Ecocardiografía Doppler , Femenino , Humanos , Masculino , Persona de Mediana Edad , Isquemia Miocárdica/fisiopatología , Isquemia Miocárdica/terapia , Variaciones Dependientes del Observador , Marcapaso Artificial , Proyectos de Investigación , Sensibilidad y Especificidad , Volumen Sistólico , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA