RESUMEN
The muscle relaxant succinylcholine (SUX) evokes respiratory paralysis, and numerous cases of fatal SUX intoxication have been reported. Detection of SUX and its metabolite succinylmonocholine (SMC) is difficult, both due to their (bis-) quaternary structure and the extreme hydrolytic susceptibility of SUX, and data on degradation kinetics of SUX and SMC is scarce. The present study investigates the in vivo and in vitro degradation as well as elimination of both target analytes using authentic blood and urine samples from anesthetized patients. With a special focus on the urinary data and stabilization issues, this work intends to considerably enhance the forensic knowledge concerning SUX intoxications and to present the reader with practical analytical strategies to cope with such difficult cases. Eighteen subjects undergoing surgery and requiring arterial as well as bladder catheters were included in this study. Muscle relaxation was initialized with a bolus injection of 80-100 mg SUX. Blood and urine samples were either collected using paraoxonized (n = 15) or non-modified (n = 3) tubes. Sampling was performed within 6 h after SUX application following a pre-assigned schedule. Samples were processed according to a validated isotope dilution HPLC-MS/MS method using ion-pair solid-phase extraction. In blood, SUX was usually detectable for up to 10 min post-injection, while detection of SMC was possible over the whole observation period of 6 h. Effectiveness of organophosphate stabilization was proven for both analytes and is therefore recommended. In freshly secreted urine, detection windows of a minimum of 2 h as opposed to 6 h have been determined for SUX versus SMC, respectively. Considering SMC plasma kinetics, detection of the metabolite in blood and freshly secreted urine appears to be possible over a period of at least 8-24 h. Paraoxon did not enhance the stability of either target substance in urine, stabilization of urine samples is nonetheless recommended. In summary, SMC was proven to be the most promising target analyte in SUX analysis, with urine being the proposed matrix of choice for forensic applications. Furthermore, our work defines meaningful detection windows for SUX and SMC in blood and urine as routine matrices and presents sampling recommendations as well as guideline values for forensic toxicological analysis.
Asunto(s)
Succinilcolina/análogos & derivados , Succinilcolina/sangre , Succinilcolina/orina , Adulto , Anciano , Femenino , Toxicología Forense/métodos , Humanos , Masculino , Persona de Mediana Edad , Adulto JovenRESUMEN
A high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) method for the simultaneous detection of succinylcholine (SUX) and its metabolite succinylmonocholine (SMC) in serum and urine is presented. For internal standardization using isotope dilution, the deuterated compounds SUX-d(18) and SMC-d(3) were employed. Full validation was performed according to international guidelines. Solid-phase extraction (SPE) of acidified samples was accomplished using Strata-X polymeric reversed phase cartridges together with heptafluorobutyric acid (HFBA) as ion-pairing reagent. Separation was achieved within 13 min on a Phenomenex Synergi Hydro RP C18 column (4 microm, 150 x 2 mm) using a gradient of 5 mM ammonium formate buffer pH 3.5 and acetonitrile.To ensure the method's applicability in forensic as well as clinical toxicology, the specific demands of both research fields were taken into account, and the method was thus validated for a low and high concentration range. For both serum and urine as sample matrix, the validation revealed good intraday and interday precisions, consistently ranging below 15% for the lowest and below 10% for elevated concentrations. Accuracy was likewise good and never exceeded 10%. Extraction recovery was excellent, ranging between 88.1 and 103.9% for SUX and SMC in both tested matrices. Matrix effects were significant, the otherwise optimized extraction and detection methods, however, allowed for a very satisfactory sensitivity of the described method: For serum, the limits of detection and quantitation were determined to be 1.9 and 6.0 ng/ml for SUX, as well as 2.5 and 8.6 ng/ml for SMC, respectively; for urine, the corresponding values were established to be 1.4 and 4.0 ng/ml (SUX), as well as 1.5 and 4.9 ng/ml (SMC).The presented method was successfully applied to authentic samples of two forensic cases investigated in the institute of forensic medicine in Bonn, allowing the diagnosis of SUX intoxications.
Asunto(s)
Fármacos Neuromusculares Despolarizantes/sangre , Fármacos Neuromusculares Despolarizantes/orina , Succinilcolina/análogos & derivados , Tampones (Química) , Cromatografía Líquida de Alta Presión , Medicina Legal , Congelación , Humanos , Técnicas de Dilución del Indicador , Espectrometría de Masas , Fármacos Neuromusculares Despolarizantes/envenenamiento , Paraoxon/química , Estándares de Referencia , Reproducibilidad de los Resultados , Solventes , Succinilcolina/sangre , Succinilcolina/envenenamiento , Succinilcolina/orinaRESUMEN
Succinylcholine (SUX) is a routinely used yet potentially lethal depolarizing muscle relaxant, the detection of which poses severe problems to the clinical or forensic analyst: within a few minutes after its in vivo administration, SUX is broken down via succinylmonocholine (SMC) to yield the endogenous substances succinic acid and choline. For quantification of SUX and SMC in biological matrices using mass spectrometric detection, appropriate internal standards, i.e. deuterated analogs of the above substances, are indispensable but not commercially available. Internal standards for both substances were hence tailored to fit the analytical needs. The two-step synthesis and subsequent characterization of SUX-d(18) and SMC-d(3) using a combination of nuclear magnetic resonance (NMR) spectroscopy, fast atom bombardment mass spectroscopy (FAB-MS) and high-performance liquid chromatography/tandem mass spectrometry (HPLC-MS/MS) are described. SUX-d(18) was synthesized by reacting ethanolamine and iodomethane-d(3) in a first quaternization step to choline-d(9), which in turn was esterified with succinyldichloride to yield the final product. SMC-d(3) was produced by esterification of succinic acid anhydride with dimethylaminoethanol, yielding desmethyl-SMC as intermediate product. The latter was then reacted with iodomethane-d(3) to obtain SMC-d(3). (1)H- and (13)C-NMR data support the identity and purity as well as the designated deuteration of both preparations, findings which were further confirmed by FAB-MS as well as HPLC-MS/MS. Owing to a thoughtful design, the obtained substances SUX-d(18) and SMC-d(3) feature different deuteration patterns at their trimethylamine moieties, and thus finally offer the possibility to simultaneously quantify SUX and SMC in clinical as well as forensic samples using isotope dilution mass spectrometry.
Asunto(s)
Fármacos Neuromusculares Despolarizantes/química , Fármacos Neuromusculares Despolarizantes/síntesis química , Succinilcolina/química , Succinilcolina/síntesis química , Cromatografía Líquida de Alta Presión , Cromatografía en Capa Delgada , Remoción de Radical Alquila , Deuterio , Espectroscopía de Resonancia Magnética , Espectrometría de Masas , Estándares de Referencia , Espectrometría de Masa Bombardeada por Átomos VelocesRESUMEN
Doubts concerning the applicability of succinylmonocholine (SMC) as a succinylcholine (SUX) marker have been issued. A comparative analysis of previously discussed tissues, i.e. brain, liver and kidney, was conducted to further elucidate this question by searching for diagnostically useful differences in analyte content in samples of SUX- versus non-SUX-associated fatalities. Furthermore, possible advantages of vitreous humor as a novel and promising target matrix for SUX analytics were assessed. Sample material of SUX-negative controls as well as the fatal SUX-intoxication was derived from frozen archive material and current autopsies. Samples were analyzed according to a modified protocol of a previously published and validated method employing ion-pairing solid-phase extraction and subsequent HPLC-MS/MS analysis. Standard addition was employed for quantification as well as an estimation of the analytical limits of the method. In all tested matrices, the method was proven to be sufficiently sensitive for the intended application. No indication of native SMC was found in controls of fresh tissues, nor in fresh or frozen vitreous humor. However, most of the samples were found to be positive for a previously reported interference with SMC's main ion transition, thereby falsely suggesting an SMC content of up to 139 ng/g, 126 ng/g, 165 ng/g and 93 ng/ml in brain, liver, kidney and vitreous humor, respectively. Contrasting the results for fresh sample material, SMC was detectable in some of the initially non-putrefied liver samples after long-term storage, as well as in massively decomposed SUX-negative control bodies. In this context, a microbial origin of the analyte may be assumed. All tissues as well as the vitreous humor of the fatal SUX-intoxication were negative for SUX and SMC. Just like serum, tissue and vitreous humor samples therefore do not allow a reliable diagnosis of a SUX-intoxication: in tissues this is due to the pronounced instability of both target analytes in these esterase-containing matrices, for vitreous humor an additional reason could be their insufficient incorporation into this medium.
Asunto(s)
Fármacos Neuromusculares Despolarizantes/envenenamiento , Succinilcolina/análogos & derivados , Succinilcolina/envenenamiento , Biomarcadores/análisis , Química Encefálica , Estudios de Casos y Controles , Toxicología Forense , Cromatografía de Gases y Espectrometría de Masas , Humanos , Riñón/química , Hígado/química , Fármacos Neuromusculares Despolarizantes/análisis , Intoxicación/diagnóstico , Succinilcolina/análisis , Cuerpo Vítreo/químicaRESUMEN
Intoxications with succinylcholine (SUX) lead to a potentially lethal respiratory paralysis, and forensic cases involving accidental or deliberate SUX-application have been reported. Detection of SUX as well as its metabolite succinylmonocholine (SMC) is difficult: both substances are analytically challenging, and the extremely short plasma half-life of SUX additionally hampers detection of the parent compound. Pharmacokinetic data are scarce on SUX and non-existent on SMC. To enhance forensic knowledge concerning SUX intoxications, plasma pharmacokinetics of SMC were investigated in anesthetized patients. Fifteen subjects scheduled for a surgical procedure were included in this study. Muscle-relaxation was initialized with a bolus injection of 80-100 mg SUX. Blood sampling was performed within 6 h after SUX application using paraoxonized tubes. Collected plasma was processed according to a validated isotope dilution high-performance liquid chromatography-tandem mass spectrometry method using ion-pair solid-phase extraction. Pharmacokinetic parameters were derived from a user-defined as well as a three-compartment model. For SMC, peak plasma concentrations were reached after 0.03-2.0 min. In contrast to SUX, SMC was more slowly and more extensively distributed, featuring triphasic plasma concentration time profiles. Pharmacokinetic key parameters were subject to interindividual variation of potential forensic importance, with terminal half-lives of 1-3 h indicating a detection interval of 8-24 h for SMC in plasma. SMC was proven to be the only realistic SUX marker in a forensic context. The present work defines meaningful detection windows for plasmatic SMC after SUX application and offers guideline values for forensic toxicological casework.
Asunto(s)
Fármacos Neuromusculares Despolarizantes/farmacocinética , Succinilcolina/análogos & derivados , Adulto , Anciano , Análisis Químico de la Sangre , Femenino , Toxicología Forense , Semivida , Humanos , Límite de Detección , Masculino , Persona de Mediana Edad , Fármacos Neuromusculares Despolarizantes/efectos adversos , Intoxicación/sangre , Intoxicación/diagnóstico , Succinilcolina/efectos adversos , Succinilcolina/farmacocinética , Adulto JovenRESUMEN
The determination and quantitation of drugs in biological matrices using high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) is becoming increasingly popular in analytical toxicology, while at the same time a growing awareness for the limits of this technique can be observed. Our group previously developed a rapid HPLC/ESI-MS/MS method for the detection and quantitation of succinylcholine (SUX) and succinylmonocholine (SMC) using ion-pairing extraction of samples with subsequent separation by gradient chromatography on a Synergi Hydro RP C18 column (4 microm, 150 x 2 mm). Identification of analytes was achieved in the multiple reaction monitoring (MRM) mode, using two characteristic ion transitions each, the respective analytes' retention time as well as co-elution of stable isotopic analogues. In both native serum as well as urine an interference with the main MRM transition of SMC was found to co-elute with this analyte, thus severely compromising the identification and quantitation of this target analyte. The interference was further shown to be eliminated from serum and urine by exposure to alkaline conditions and hence proven to share a key physicochemical property with SMC. The observed absence of the second and third most intense ion transitions of SMC in the unknown substance was the only useful distinction between both compounds.The detailed presentation of selectivity problems encountered during method development is intended to initiate further discussion on this yet underrepresented issue in HPLC/MS/MS. The present work emphasizes the need to monitor more than just one ion transition to confidently rule out signal interferences, ensure correct analyte identification as well as quantitation, and thus avoid false-positive results. In this context, the employment of minor MRM transitions for the quantitation and identification of a given analyte is presented as a satisfactory solution to HPLC/MS/MS selectivity problems, and proposed as a possible alternative to previously published approaches.