Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Int J Mol Sci ; 24(15)2023 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-37569707

RESUMEN

COVID-19 is an ongoing, global pandemic caused by the novel, highly infectious SARS-CoV-2 virus. Efforts to mitigate the effects of SARS-CoV-2, such as mass vaccination and development of monoclonal therapeutics, require precise measurements of correlative, functional neutralizing antibodies that block virus infection. The development of rapid, safe, and easy-to-use neutralization assays is essential for faster diagnosis and treatment. Here, we developed a vesicular stomatitis virus (VSV)-based neutralization assay with two readout methods, imaging and flow cytometry, that were capable of quantifying varying degrees of neutralization in patient serum samples. We tested two different spike-pseudoviruses and conducted a time-course assay at multiple multiplicities of infection (MOIs) to optimize the assay workflow. The results of this assay correlate with the results of previously developed serology and surrogate neutralization assays. The two pseudovirus readout methods produced similar values of 50% neutralization titer values. Harvest-free in situ readouts for live-cell imaging and high-throughput analysis results for flow cytometry can provide unique capabilities for fast evaluation of neutralization, which is critical for the mitigation of future pandemics.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , Citometría de Flujo , Anticuerpos Antivirales , Pruebas de Neutralización/métodos , Anticuerpos Neutralizantes
2.
Int J Mol Sci ; 24(21)2023 Oct 28.
Artículo en Inglés | MEDLINE | ID: mdl-37958688

RESUMEN

COVID-19 has highlighted challenges in the measurement quality and comparability of serological binding and neutralization assays. Due to many different assay formats and reagents, these measurements are known to be highly variable with large uncertainties. The development of the WHO international standard (WHO IS) and other pool standards have facilitated assay comparability through normalization to a common material but does not provide assay harmonization nor uncertainty quantification. In this paper, we present the results from an interlaboratory study that led to the development of (1) a novel hierarchy of data analyses based on the thermodynamics of antibody binding and (2) a modeling framework that quantifies the probability of neutralization potential for a given binding measurement. Importantly, we introduced a precise, mathematical definition of harmonization that separates the sources of quantitative uncertainties, some of which can be corrected to enable, for the first time, assay comparability. Both the theory and experimental data confirmed that mAbs and WHO IS performed identically as a primary standard for establishing traceability and bridging across different assay platforms. The metrological anchoring of complex serological binding and neuralization assays and fast turn-around production of an mAb reference control can enable the unprecedented comparability and traceability of serological binding assay results for new variants of SARS-CoV-2 and immune responses to other viruses.


Asunto(s)
COVID-19 , SARS-CoV-2 , Humanos , Anticuerpos Monoclonales , Bioensayo , Análisis de Datos , Anticuerpos Antivirales , Anticuerpos Neutralizantes
3.
J Proteome Res ; 21(5): 1229-1239, 2022 05 06.
Artículo en Inglés | MEDLINE | ID: mdl-35404046

RESUMEN

Mass spectrometry (MS)-based proteomic measurements are uniquely poised to impact the development of cell and gene therapies. With the adoption of rigorous instrumental performance qualifications (PQs), large-scale proteomics can move from a research to a manufacturing control tool. Especially suited, data-independent acquisition (DIA) approaches have distinctive qualities to extend multiattribute method (MAM) principles to characterize the proteome of cell therapies. Here, we describe the development of a DIA method for the sensitive identification and quantification of proteins on a Q-TOF instrument. Using the improved acquisition parameters, we defined a control strategy and highlighted some metrics to improve the reproducibility of SWATH acquisition-based proteomic measurements. Finally, we applied the method to analyze the proteome of Jurkat cells that here serves as a model for human T-cells. Raw and processed data were deposited in PRIDE (PXD029780).


Asunto(s)
Proteoma , Proteómica , Exactitud de los Datos , Humanos , Espectrometría de Masas/métodos , Proteoma/análisis , Proteómica/métodos , Reproducibilidad de los Resultados
4.
Methods Mol Biol ; 2779: 259-271, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38526789

RESUMEN

COVID-19 is a global pandemic caused by the highly infectious SARS-CoV-2 virus. Efforts to combat SARS-CoV-2 infection include mass vaccination and development of monoclonal and convalescent plasma therapeutics that require precise measurements of correlative, functional neutralizing antibodies that prevent virus infection. Developing rapid, safe, easy-to-use, and high-quality neutralization assays are essential for the success of the massive effort. Here, we developed a vesicular stomatitis virus-based neutralization assay that was capable of quantifying varying degrees of neutralization in patient serum samples. This assay has two detection readouts, flow cytometry and live cell imaging. The two readout methods produced consistent values of all 50% neutralization titers, further enhancing measurement confidence on the assay. Moreover, the use of available reference standards such as the World Health Organization International Standard (NIBSC code 20/136) enables quantification and standardization of the pseudovirus neutralization assay with neutralizing antibody titers measured in International Units/mL. Quantitative and standardized neutralization assays are critical for reliable efficacy evaluation and comparison of numerous vaccines and therapeutics.


Asunto(s)
COVID-19 , Humanos , SARS-CoV-2 , Sueroterapia para COVID-19 , Pruebas Inmunológicas , Citometría de Flujo , Anticuerpos Neutralizantes , Anticuerpos Antivirales , Pruebas de Neutralización , Glicoproteína de la Espiga del Coronavirus
5.
Sci Rep ; 13(1): 14470, 2023 09 02.
Artículo en Inglés | MEDLINE | ID: mdl-37660227

RESUMEN

Lentiviral vectors (LV) have proven to be powerful tools for stable gene delivery in both dividing and non-dividing cells. Approval of these LVs for use in clinical applications has been achieved by improvements in LV design. Critically important characteristics concerning quality control are LV titer quantification and the detection of impurities. However, increasing evidence concerning high variability in titration assays indicates poor harmonization of the methods undertaken to date. In this study, we developed a direct reverse transcription droplet digital PCR (Direct RT-ddPCR) approach without RNA extraction and purification for estimation of LV titer and RNA genome integrity. The RNA genome integrity was assessed by RT-ddPCR assays targeted to four distant regions of the LV genome. Results of the analyses showed that direct RT-ddPCR without RNA extraction and purification performs similarly to RT-ddPCR on purified RNA from 3 different LV samples, in terms of robustness and assay variance. Interestingly, these RNA titer results were comparable to physical titers by p24 antigen ELISA (enzyme-linked immunosorbent assay). Moreover, we confirmed the partial degradation or the incomplete RNA genomes in the prepared 3 LV samples. These results may partially explain the discrepancy of the LV particle titers to functional titers. This work not only demonstrates the feasibility of direct RT-ddPCR in determining LV titers, but also provides a method that can be easily adapted for RNA integrity assessment.


Asunto(s)
ARN , Transcripción Reversa , Bioensayo , Ensayo de Inmunoadsorción Enzimática , Reacción en Cadena de la Polimerasa
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA