Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur Spine J ; 33(8): 2969-2981, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39009847

RESUMEN

PURPOSE: Cervical total disc replacement (cTDR) has been established as an alternative treatment for degenerative cervical radiculopathy and myelopathy. While the rate of complications for cTDR is reasonably low, recent studies have focused on bone loss after cTDR. The purpose of this work is to develop a clinical management plan for cTDR patients with evidence of bone loss. To guide our recommendations, we undertook a review of the literature and aimed to determine: (1) how bone loss was identified/imaged, (2) whether pre- or intraoperative assessments of infection or histology were performed, and (3) what decision-making and revision strategies were employed. METHODS: We performed a search of the literature according to PRISMA guidelines. Included studies reported the clinical performance of cTDR and identified instances of cervical bone loss. RESULTS: Eleven case studies and 20 cohort studies were reviewed, representing 2073 patients with 821 reported cases of bone loss. Bone loss was typically identified on radiographs during routine follow-up or by computed tomography (CT) for patients presenting with symptoms. Assessments of infection as well as histological and/or explant assessment were sporadically reported. Across all reviewed studies, multiple mechanisms of bone loss were suspected, and severity and progression varied greatly. Many patients were reportedly asymptomatic, but others experienced symptoms like progressive pain and paresthesia. CONCLUSION: Our findings demonstrate a critical gap in the literature regarding the optimal management of patients with bone loss following cTDR, and treatment recommendations based on our review are impractical given the limited amount and quality evidence available. However, based on the authors' extensive clinical experience, close follow-up of specific radiographic observations and serial radiographs to assess the progression/severity of bone loss and implant changes are recommended. CT findings can be used for clinical decision-making and further follow-up care. The pattern and rate of progression of bone loss, in concert with patient symptomatology, should determine whether non-operative or surgical intervention is indicated. Future studies involving implant retrieval, histopathological, and microbiological analysis for patients undergoing cTDR revision for bone loss are needed.


Asunto(s)
Vértebras Cervicales , Reeemplazo Total de Disco , Humanos , Reeemplazo Total de Disco/métodos , Reeemplazo Total de Disco/efectos adversos , Vértebras Cervicales/cirugía , Vértebras Cervicales/diagnóstico por imagen , Resorción Ósea/diagnóstico por imagen , Resorción Ósea/etiología , Complicaciones Posoperatorias/etiología
2.
Clin Orthop Relat Res ; 475(5): 1369-1381, 2017 May.
Artículo en Inglés | MEDLINE | ID: mdl-27488379

RESUMEN

BACKGROUND: The pathophysiology and mechanisms driving the generation of unintended pain after total disc replacement (TDR) remain unexplored. Ultrahigh-molecular-weight polyethylene (UHMWPE) wear debris from TDRs is known to induce inflammation, which may result in pain. QUESTIONS/PURPOSES: The purpose of this study was to determine whether (1) periprosthetic UHMWPE wear debris induces immune responses that lead to the production of tumor necrosis factor-α (TNFα) and interleukin (IL)-1ß, the vascularization factors, vascular endothelial growth factor (VEGF) and platelet-derived growth factor-bb (PDGFbb), and the innervation/pain factors, nerve growth factor (NGF) and substance P; (2) the number of macrophages is associated with the production of the aforementioned factors; (3) the wear debris-induced inflammatory pathogenesis involves an increase in vascularization and associated innervation. METHODS: Periprosthetic tissues from our collection of 11 patients with contemporary TDRs were evaluated using polarized light microscopy to quantify UHMWPE wear particles. The major reason for revision (mean implantation time of 3 years [range, 1-6 years]) was pain. For control subjects, biopsy samples from four patients with degenerative disc disease with severe pain and autopsy samples from three normal patients with no history of back pain were also investigated. Immunohistochemistry and histology were used to identify secretory factors, macrophages, and blood vessels. Immunostained serial sections were imaged at ×200 magnification and using MATLAB and NIH ImageJ, a threshold was determined for each factor and used to quantify positive staining normalized to tissue sectional area. The Mann-Whitney U test was used to compare results from different patient groups, whereas the Spearman Rho test was used to determine correlations. Significance was based on p < 0.05. RESULTS: The mean percent area of all six inflammatory, vascularization, and innervation factors was higher in TDR tissues when compared with normal disc tissues. Based on nonparametric data analysis, those factors showing the most significant increase included TNFα (5.17 ± 1.76 versus 0.05 ± 0.03, p = 0.02), VEGF (3.02 ± 1.01 versus 0.02 ± 0.002, p = 0.02), and substance P (4.15 ± 1.01 versus 0.08 ± 0.04, p = 0.02). The mean percent area for IL-1ß (2.41 ± 0.66 versus 0.13 ± 0.13, p = 0.01), VEGF (3.02 ± 1.01 versus 0.34 ± 0.29, p = 0.04), and substance P (4.15 ± 1.01 versus 1.05 ± 0.46, p = 0.01) was also higher in TDR tissues when compared with disc tissues from patients with painful degenerative disc disease. Five of the factors, TNFα, IL-1ß, VEGF, NGF, and substance P, strongly correlated with the number of wear particles, macrophages, and blood vessels. The most notable correlations included TNFα with wear particles (p < 0.001, ρ = 0.63), VEGF with macrophages (p = 0.001, ρ = 0.71), and NGF with blood vessels (p < 0.001, ρ = 0.70). Of particular significance, the expression of PDGFbb, NGF, and substance P was predominantly localized to blood vessels/nerve fibers. CONCLUSIONS: These findings indicate wear debris-induced inflammatory reactions can be linked to enhanced vascularization and associated innervation/pain factor production at periprosthetic sites around TDRs. Elucidating the pathogenesis of inflammatory particle disease will provide information needed to identify potential therapeutic targets and treatment strategies to mitigate pain and potentially avoid revision surgery. LEVEL OF EVIDENCE: Level III, therapeutic study.


Asunto(s)
Discitis/etiología , Degeneración del Disco Intervertebral/cirugía , Disco Intervertebral/cirugía , Dolor de la Región Lumbar/etiología , Vértebras Lumbares/cirugía , Dolor Postoperatorio/etiología , Polietilenos , Reeemplazo Total de Disco/efectos adversos , Reeemplazo Total de Disco/instrumentación , Adulto , Biopsia , Citocinas/metabolismo , Remoción de Dispositivos , Discitis/diagnóstico , Discitis/fisiopatología , Discitis/cirugía , Femenino , Humanos , Inmunohistoquímica , Mediadores de Inflamación/metabolismo , Disco Intervertebral/irrigación sanguínea , Disco Intervertebral/inervación , Disco Intervertebral/metabolismo , Degeneración del Disco Intervertebral/diagnóstico , Degeneración del Disco Intervertebral/fisiopatología , Dolor de la Región Lumbar/diagnóstico , Dolor de la Región Lumbar/fisiopatología , Dolor de la Región Lumbar/cirugía , Vértebras Lumbares/irrigación sanguínea , Vértebras Lumbares/inervación , Vértebras Lumbares/metabolismo , Macrófagos/metabolismo , Masculino , Persona de Mediana Edad , Neovascularización Patológica , Dimensión del Dolor , Dolor Postoperatorio/diagnóstico , Dolor Postoperatorio/fisiopatología , Dolor Postoperatorio/cirugía , Diseño de Prótesis , Reoperación , Factores de Riesgo , Estrés Mecánico , Sustancia P/metabolismo , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos , Factor A de Crecimiento Endotelial Vascular/metabolismo , Adulto Joven
3.
Eur Spine J ; 24 Suppl 4: S494-501, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25163549

RESUMEN

PURPOSE: Few complications have been reported for lumbar total disc replacement (TDR) and hybrid TDR fixations. This study evaluated retrieved implants and periprosthetic tissue reactions for two cases of osteolysis following disc arthroplasty with ProDisc-L prostheses. METHODS: Implants were examined for wear and surface damage, and tissues for inflammation, polyethylene wear debris (polarized light microscopy) and metal debris (energy-dispersive X-ray spectroscopy). RESULTS: Despite initial good surgical outcomes, osteolytic cysts were noted in both patients at vertebrae adjacent to the implants. For the hybrid TDR case, heterotopic ossification and tissue necrosis due to wear-induced inflammation were observed. In contrast, the non-hybrid implant showed signs of abrasion and impingement, and inflammation was observed in tissue regions with metal and polyethylene wear debris. CONCLUSIONS: In both cases, wear debris and inflammation may have contributed to osteolysis. Surgeons using ProDisc prostheses should be aware of these rare complications.


Asunto(s)
Prótesis Articulares/efectos adversos , Vértebras Lumbares/cirugía , Osteólisis/etiología , Complicaciones Posoperatorias/etiología , Reeemplazo Total de Disco/instrumentación , Adulto , Remoción de Dispositivos , Humanos , Masculino , Persona de Mediana Edad , Osteólisis/diagnóstico , Complicaciones Posoperatorias/diagnóstico , Falla de Prótesis/efectos adversos , Reeemplazo Total de Disco/métodos
4.
Clin Orthop Relat Res ; 473(3): 987-98, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25367112

RESUMEN

BACKGROUND: Lumbar total disc replacement (L-TDR) is a procedure used to relieve back pain and maintain mobility. Contemporary metal-on-polyethylene (MoP) L-TDRs were developed to address wear performance concerns about historical designs, but wear debris generation and periprosthetic tissue reactions for these newer implants have not been determined. QUESTIONS/PURPOSES: The purpose of this study was to determine (1) whether periprosthetic ultrahigh-molecular-weight polyethylene (UHMWPE) wear debris and biological responses were present in tissues from revised contemporary MoP L-TDRs that contain conventional cores fabricated from γ-inert-sterilized UHMWPE; (2) how fixed- versus mobile-bearing design affected UHMWPE wear particle number, shape, and size; and (3) how these wear particle characteristics compare with historical MoP L-TDRs that contain cores fabricated from γ-air-sterilized UHMWPE. METHODS: We evaluated periprosthetic tissues from 11 patients who received eight fixed-bearing ProDisc-L and four mobile-bearing CHARITÉ contemporary L-TDRs with a mean implantation time of 4.1 and 2.7 years, respectively. Histologic analysis of tissues was performed to assess biological responses and polarized light microscopy was used to quantify number and size/shape characteristics of UHMWPE wear particles from the fixed- and mobile-bearing devices. Comparisons were made to previously reported particle data for historical L-TDRs. RESULTS: Five of seven (71%) fixed-bearing and one of four mobile-bearing L-TDR patient tissues contained at least 4 particles/mm(2) wear with associated macrophage infiltration. Tissues with wear debris were highly vascularized, whereas those without debris were more necrotic. Given the samples available, the tissue around mobile-bearing L-TDR was observed to contain 87% more, 11% rounder, and 11% less-elongated wear debris compared with tissues around fixed-bearing devices; however, there were no significant differences. Compared with historical L-TDRs, UHMWPE particle number and circularity for contemporary L-TDRs were 99% less (p = 0.003) and 50% rounder (p = 0.003). CONCLUSIONS: In this preliminary study, short-term results suggest there was no significant influence of fixed- or mobile-bearing designs on wear particle characteristics of contemporary L-TDRs, but conventional UHMWPE has notably improved the wear resistance of these devices compared with historical UHMWPE.


Asunto(s)
Disco Intervertebral/cirugía , Vértebras Lumbares/cirugía , Ensayo de Materiales , Prótesis e Implantes , Diseño de Prótesis , Falla de Prótesis , Reeemplazo Total de Disco/instrumentación , Adulto , Materiales Biocompatibles , Femenino , Humanos , Degeneración del Disco Intervertebral/cirugía , Desplazamiento del Disco Intervertebral/cirugía , Dolor de la Región Lumbar/cirugía , Masculino , Persona de Mediana Edad , Polietilenos
5.
J Orthop Surg Res ; 19(1): 218, 2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38566203

RESUMEN

BACKGROUND: The goal of this study is to propose a classification system with a common nomenclature for radiographic observations of periprosthetic bone changes following cTDR. METHODS: Aided by serial plain radiographs from recent cTDR cases (34 patients; 44 devices), a panel of experts assembled for the purpose of creating a classification system to aid in reproducibly and accurately identifying bony changes and assessing cTDR radiographic appearance. Subdividing the superior and inferior vertebral bodies into 3 equal sections, observed bone loss such as endplate rounding, cystic erosion adjacent to the endplate, and cystic erosion not adjacent to the endplate, is recorded. Determining if bone loss is progressive, based on serial radiographs, and estimating severity of bone loss (measured by the percentage of end plate involved) is recorded. Additional relevant bony changes and device observations include radiolucent lines, heterotopic ossification, vertebral body olisthesis, loss of core implant height, and presence of device migration, and subsidence. RESULTS: Serial radiographs from 19 patients (25 devices) implanted with a variety of cTDR designs were assessed by 6 investigators including clinicians and scientists experienced in cTDR or appendicular skeleton joint replacement. The overall agreement of assessments ranged from 49.9% (95% bootstrap confidence interval 45.1-73.1%) to 94.7% (95% CI 86.9-100.0%). There was reasonable agreement on the presence or absence of bone loss or radiolucencies (range: 58.4% (95% CI 51.5-82.7%) to 94.7% (95% CI 86.9-100.0%), as well as in the progression of radiolucent lines (82.9% (95% CI 74.4-96.5%)). CONCLUSIONS: The novel classification system proposed demonstrated good concordance among experienced investigators in this field and represents a useful advancement for improving reporting in cTDR studies.


Asunto(s)
Degeneración del Disco Intervertebral , Reeemplazo Total de Disco , Humanos , Resultado del Tratamiento , Discectomía , Vértebras Cervicales/diagnóstico por imagen , Vértebras Cervicales/cirugía , Cuello , Degeneración del Disco Intervertebral/cirugía
6.
N Am Spine Soc J ; 18: 100320, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38590972

RESUMEN

Background: Total disc replacement (TDR) is widely used in the treatment of cervical and lumbar spine pathologies. Although TDR infection, particularly delayed infection, is uncommon, the results can be devastating, and consensus on clinical management remains elusive. In this review of the literature, we asked: (1) What are the reported rates of TDR infection; (2) What are the clinical characteristics of TDR infection; and (3) How has infection been managed for TDR patients? Methods: We performed a search of the literature using PubMed and Embase to identify studies that reported TDR infection rates, the identification and management of TDR infection, or TDR failures with positive cultures. Twenty database studies (17 focusing on the cervical spine and 3 on the lumbar spine) and 10 case reports representing 15 patients were reviewed along with device Summary of Safety and Effectiveness Data reports. Results: We found a lack of clarity regarding how infection was diagnosed, indicating a variation in clinical approach and highlighting the need for a standard definition of TDR infection. Furthermore, while reported infection rates were low, the absence of a clear definition prevented robust data analysis and may contribute to underreporting in the literature. We found that treatment strategy and success rely on several factors including patient symptoms and time to onset, microorganism type, and implant positioning/stability. Conclusions: Although treatment strategies varied throughout the extant literature, common practices in eliminating infection and reconstructing the spine emerged. The results will inform future work on the creation of a more robust definition of TDR infection and as well as recommendations for management.

7.
Eur Spine J ; 22(12): 2752-9, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23887771

RESUMEN

INTRODUCTION: The purpose of this study was to analyze explanted PEEK rod spinal systems in the context of their clinical indications. We evaluated damage to the implant and histological changes in explanted periprosthetic tissues. METHODS: 12 patients implanted with 23 PEEK rods were revised between 2008 and 2012. PEEK rods were of the same design (CD Horizon Legacy, Medtronic, Memphis TN, USA). Retrieved components were assessed for surface damage mechanisms, including plastic deformation, scratching, burnishing, and fracture. Patient history and indications for PEEK rod implantation were obtained from analysis of the medical records. RESULTS: 11/12 PEEK rod systems were employed for fusion at one level, and motion preservation at the adjacent level. Surgical complications in the PEEK cohort included a small dural tear in one case that was immediately repaired. There were no cases of PEEK rod fracture or pedicle screw fracture. Retrieved PEEK rods exhibited scratching, as well as impressions from the set screws and pedicle screw saddles. PEEK debris was observed in two patient tissues, which were located adjacent to PEEK rods with evidence of scratching and burnishing. CONCLUSION: This study documents the surface changes and tissue reactions for retrieved PEEK rod stabilization systems. Permanent indentations by the set screws and pedicle screws were the most prevalent observations on the surface of explanted PEEK rods.


Asunto(s)
Análisis de Falla de Equipo/métodos , Vértebras Lumbares/patología , Vértebras Lumbares/cirugía , Fusión Vertebral/instrumentación , Fusión Vertebral/métodos , Adulto , Benzofenonas , Tornillos Óseos , Femenino , Humanos , Fijadores Internos , Degeneración del Disco Intervertebral/terapia , Cetonas , Vértebras Lumbares/diagnóstico por imagen , Vértebras Lumbares/fisiopatología , Masculino , Persona de Mediana Edad , Movimiento (Física) , Polietilenglicoles , Polímeros , Estudios Prospectivos , Prótesis e Implantes , Radiografía , Rango del Movimiento Articular , Reoperación
8.
N Am Spine Soc J ; 16: 100294, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38162168

RESUMEN

Background: Motion of a solid body involves translation and rotation. Few investigations examine the isolated translational and rotational components associated with disc arthroplasty devices. This study investigates single- and multi-level cervical disc arthroplasty with respect to index and adjacent level range of motion. The investigators hypothesized that single- and multilevel cervical disc replacement will lead to comparable or improved motion at implanted and adjacent levels. Methods: Seven human cervical spines from C2 to C7 were subjected to displacement-controlled loading in flexion, extension, and lateral bending under intact, 1-Level (C5-C6), 2-Level (C5-C6, C6-C7) and 3-Level (C5-C6, C6-C7, C4-C5) conditions. 3D motions sensors were mounted at C4, C5, and C6. Motion data for translations and rotations at each level for each surgical condition and loading mode were compared to intact conditions. Results: 1-Level: The index surgery resulted in statistically increased translations in extension and lateral bending at all levels with statistically increased translation observed in flexion in the superior and inferior levels. In rotation, the index surgeries decreased rotation under flexion, with remaining levels not statistically different to intact conditions. 2-Level: A device placed inferiorly resulted in statistically increased translations at all levels in extension with statistically increased translations superior and inferior to the index level in flexion. Lateral bending resulted in increased nonsignificant translations. Rotations were elevated or comparable to the intact level for all loading. 3-Level: Translations were statistically increased for all levels in all loading modes while rotations were elevated or were comparable to the intact level for all loading modes and levels. Conclusions: Micromotion sensors permitted monitoring and recording of small magnitude angulations and translations using a loading mechanism that did not over constrain cervical segmental motion. Multilevel cervical disc arthroplasty yielded comparable or increased overall motion at the index and adjacent levels compared to intact conditions.

9.
JBJS Case Connect ; 13(3)2023 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-37418554

RESUMEN

CASE: A 22-year-old woman with Klippel-Feil syndrome who underwent cervical disc arthroplasty (CDA) presented 3 months postoperatively with worsening neck pain and radiculopathy. Work-up was negative for infection, but single-photon emission computed tomography revealed increased metabolic activity in the vertebral body below the implant. During revision, the implant was grossly loose and multiple cultures grew Cutibacterium acnes. She was treated with an antibiotic course and conversion to anterior fusion without recurrence. CONCLUSION: This report highlights the rare presentation of an early periprosthetic infection after CDA caused by C. acnes.


Asunto(s)
Vértebras Cervicales , Radiculopatía , Femenino , Humanos , Adulto Joven , Adulto , Vértebras Cervicales/diagnóstico por imagen , Vértebras Cervicales/cirugía , Resultado del Tratamiento , Artroplastia/métodos , Dolor de Cuello/etiología , Radiculopatía/cirugía
10.
Int J Spine Surg ; 16(2): 384-392, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35444046

RESUMEN

BACKGROUND: Patients may occasionally have persistent or recurrent radicular symptoms after cervical artificial disc replacement (ADR) for cervical spondylotic radiculopathy. We describe our approach using anterior cervical foraminotomy (ACF) to provide symptom relief in such patients without the need to convert to a fusion or remove the ADR implant. METHODS: Our operative technique for ACF after cervical ADR begins by starting at the lateral edge of the ADR at the superior end plate of the inferior vertebral body. The ipsilateral uncovertebral joint is drilled with a combination of a high-speed burr and diamond-coated burr to minimize the risk of injury to the vertebral artery. The neuroforamen is entered after drilling through the posterior aspect of the uncinate process. The exiting cervical nerve root should be directly visualized, and a Kerrison rongeur may be used to trace along the nerve root laterally to remove any remaining uncinate osteophyte or process. We queried our internal database for patients with recurrent or new radicular pain following cervical ADR who underwent ACF. Clinical characteristics and outcomes were reported. RESULTS: Five patients with recurrent radicular symptoms after ADR were reviewed. Two ACFs were performed at C5-6, and 2 were performed at C6-7. Four patients developed ipsilateral recurrent radicular symptoms, and only 1 patient developed contralateral new radicular symptoms. Three patients reported complete resolution of their new or recurrent radicular symptoms following ACF, and 2 patients reported only partial resolution. No patients required conversion to a fusion. CONCLUSIONS: In patients with recurrent symptoms of cervical spondylotic radiculopathy following ADR, ACF with uncovertebral joint resection can be used to provide direct foraminal decompression without the need for implant removal. This approach also preserves motion at the affected level, preserves cervical spinal stability, and prevents the need for spinal fusion. CLINICAL RELEVANCE: Patients with persistent or recurrent radicular symptoms after cervical ADR may achieve resolution of symptoms through a modified ACF technique.

11.
Int J Spine Surg ; 16(1): 95-101, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35273107

RESUMEN

BACKGROUND: Driving an automobile requires the ability to turn the neck laterally. Anecdotally, patients with multilevel fusions often complain about restricted turning motion. The purpose of this study was to compare the effectiveness of cervical disc arthroplasty (CDA) with anterior cervical discectomy and fusion (ACDF) on driving disability improvement at 10-year follow-up after a 2-level procedure. METHODS: In the original randomized controlled trial, patients with cervical radiculopathy or myelopathy at 2 levels underwent CDA or ACDF. The driving disability question from the Neck Disability Index was rated from 0 to 5 years preoperatively and up to 10 years postoperatively. Severity of driving disability was categorized into "none" (score 0), "mild" (1 or 2), and "severe" (3, 4, or 5). Score and severity were compared between groups. RESULTS: Out of 397 patients, 148 CDA and 118 ACDF patients had 10-year follow-up. Driving disability scores were not different between the groups preoperatively (CDA: 2.65; ACDF: 2.71, P = 0.699). Postoperatively, the scores in the CDA group were significantly lower than those in the ACDF group at 5 (0.60 vs 1.08, P ≤ 0.001) and 10 years (0.66 vs 1.07, P = 0.001). Mean score improvement in the CDA group was significantly greater than the ACDF group at 10-year follow-up (-1.94 vs -1.63, P = 0.003). The majority of patients reported severe driving disability (CDA: 56.9%, ACDF: 58.0%, P = 0.968) before surgery. After surgery, a greater proportion of patients in the CDA group had neck pain-free driving compared with the ACDF group at 5 (63.3% vs 41.8%, P < 0.001) and 10 years (61.8% vs 41.2%, P = 0.003). CONCLUSION: In patients with cervical radiculopathy/myelopathy and 2-level disease, CDA provided greater improvements in driving disability as compared with ACDF at 10-year follow-up. This is the first report of its kind. This finding may be attributable to preservation of motion associated with CDA. CLINICAL RELEVENCE: This study provides valuable information regarding the improvement of driving disability after both CDA and ACDF. It demonstrates that both procedures result in significant improvements, with CDA resulting in even better improvements than ACDF, up to 10 year follow-up.

12.
J Biomech Eng ; 133(8): 081009, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21950902

RESUMEN

The concept of semi-rigid fixation (SRF) has driven the development of spinal implants that utilize nonmetallic materials and novel rod geometries in an effort to promote fusion via a balance of stability, intra- and inter-level load sharing, and durability. The purpose of this study was to characterize the mechanical and biomechanical properties of a pedicle screw-based polyetheretherketone (PEEK) SRF system for the lumbar spine to compare its kinematic, structural, and durability performance profile against that of traditional lumbar fusion systems. Performance of the SRF system was characterized using a validated spectrum of experimental, computational, and in vitro testing. Finite element models were first used to optimize the size and shape of the polymeric rods and bound their performance parameters. Subsequently, benchtop tests determined the static and dynamic performance threshold of PEEK rods in relevant loading modes (flexion-extension (F/E), axial rotation (AR), and lateral bending (LB)). Numerical analyses evaluated the amount of anteroposterior column load sharing provided by both metallic and PEEK rods. Finally, a cadaveric spine simulator was used to determine the level of stability that PEEK rods provide. Under physiological loading conditions, a 6.35 mm nominal diameter oval PEEK rod construct unloads the bone-screw interface and increases anterior column load (approx. 75% anterior, 25% posterior) when compared to titanium (Ti) rod constructs. The PEEK construct's stiffness demonstrated a value lower than that of all the metallic rod systems, regardless of diameter or metallic composition (78% < 5.5 mm Ti; 66% < 4.5 mm Ti; 38% < 3.6 mm Ti). The endurance limit of the PEEK construct was comparable to that of clinically successful metallic rod systems (135N at 5 × 10(6) cycles). Compared to the intact state, cadaveric spines implanted with PEEK constructs demonstrated a significant reduction of range of motion in all three loading directions (> 80% reduction in F/E, p < 0.001; > 70% reduction in LB, p < 0.001; > 54% reduction in AR, p < 0.001). There was no statistically significant difference in the stability provided by the PEEK rods and titanium rods in any mode (p = 0.769 for F/E; p = 0.085 for LB; p = 0.633 for AR). The CD HORIZON(®) LEGACY(™) PEEK Rod System provided intervertebral stability comparable to currently marketed titanium lumbar fusion constructs. PEEK rods also more closely approximated the physiologic anteroposterior column load sharing compared to results with titanium rods. The durability, stability, strength, and biomechanical profile of PEEK rods were demonstrated and the potential advantages of SRF were highlighted.


Asunto(s)
Tornillos Óseos , Cetonas , Vértebras Lumbares/cirugía , Ensayo de Materiales/métodos , Polietilenglicoles , Fusión Vertebral/instrumentación , Benzofenonas , Fenómenos Biomecánicos , Análisis de Elementos Finitos , Humanos , Polímeros , Reproducibilidad de los Resultados , Resistencia al Corte , Estrés Mecánico
13.
Int J Spine Surg ; 15(5): 971-977, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34625452

RESUMEN

BACKGROUND: Single and multilevel lumbar arthroplasty has had excellent results, but the L5-S1 level frequently has pathology that precludes arthroplasty. This study evaluated clinical outcomes and sagittal range of motion (ROM) of operated levels and adjacent motion segments in single- and multiple-level ProDisc-L above a simultaneous L5-S1 fusion (hybrid) after a 2- to 6-year follow-up. METHODS: In this prospective cohort study, 46 patients underwent simultaneous lumbar total disc replacement (TDR) at one to three levels and anterior lumbar interbody fusion (ALIF) at L5-S1. Twenty-three patients had L5-S1 ALIF + L4-5 TDR, 19 patients had L5-S1 ALIF + two-level TDR, and 4 patients had L5-S1 ALIF + three-level TDR. Oswestry disability index (ODI) and visual analog scores (VAS) of patient satisfaction (VAS-S) and pain (VAS-P) were recorded. Sagittal motion on pre- and postoperative lumbar radiographs at each operative segment and adjacent segment was acquired. Patients were evaluated preoperatively and at 6 weeks, 3 months, 6 months, and annually for 24 to 72 months postoperatively. RESULTS: For clinical results, there were no differences among the groups for age, gender, body mass index, tobacco use, or worker's compensation status. At 2-6 years postoperation, all patients had significant reductions in ODI and VAS scores. For radiographic results, at the nonsurgical level adjacent to the TDR + ALIF constructs, the mean preoperative ROM was 9.40 ± 1.80° compared with 10.50 ± 2.25° postoperatively. The mean preoperative ROM at levels undergoing TDR was 10.4 ± 2.71° versus 12.6 ± 2.25° postoperatively. There was no statistically significant difference in ROM at each prosthetic motion segment between patients receiving one-, two-, or three-level TDR. The mean preoperative ROM at the L5-S1 segment to undergo fusion was 2.4 ± 2.44°, with all patients having a postoperative ROM of 0.00°. CONCLUSIONS: Multilevel TDR above an L5-S1 ALIF (hybrid procedure) preserves ROM at the individual TDR levels and does not reduce the fusion rate of the L5-S1 fused level. Most significantly, the nonoperative adjacent level maintains its preoperative ROM at 2-6 years postoperatively.

14.
Int J Spine Surg ; 15(5): 937-944, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34551930

RESUMEN

BACKGROUND: The frequency and complexity of spinal surgery performed in an ambulatory surgery center (ASC) is increasing. However, safety and efficacy data of most spinal procedures adapted to the ASC are sparse and have focused on anterior cervical surgery. The purpose of this study was to compare the 90-day complication and readmission rates of anterior lumbar spine surgery performed in an ASC or inpatient setting. METHODS: We performed a retrospective comparative analysis of 226 consecutive anterior lumbar surgeries (283 levels treated) completed in an ASC (n = 124) or in an inpatient tertiary care hospital (n = 102) over a 3-year period. These included anterior lumbar interbody fusion (ALIF), artificial disc replacement (ADR), and hybrids. Patients undergoing simultaneous or staged posterior procedures within 3 months were excluded. Patient demographics and surgical parameters between the two surgical settings were compared. Ninety-day medical complications and readmission rates were assessed. One-way analysis of variance and Chi-square analysis were used. A P value of less than .05 was considered statistically significant. RESULTS: The two study groups had similar baseline characteristics. While there was a trend toward fewer complications, reoperations, and readmissions for the ASC cohort, the differences were not statistically significant. There were 7 intraoperative complications (5.6% minor vascular injury) in the inpatient cohort and 0 in the ASC cohort. The overall 90-day postoperative complication rate was 5.6% for the inpatient cohort and 0.9% for the ASC cohort. The 90-day readmission rate was 1.9% in the ASC cohort and 1.6% in the inpatient cohort. The 90-day reoperation rate was 0.8% for the inpatient cohort and 0% in the ASC cohort. The average hospital stay was 2.3 ± 1.5 days for the inpatient cohort. CONCLUSION: The 90-day readmission rates were lower for outpatients than for inpatients, while the complication and reoperation rates were similar. Our results demonstrate that anterior lumbar procedures, including single-level and multilevel ALIF, ADR, and hybrid procedures, can be performed safely in an ASC. This has significant cost savings implications for the ASC setting.

15.
Spine (Phila Pa 1976) ; 45(8): 512-521, 2020 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-31703051

RESUMEN

STUDY DESIGN: Retrospective cohort. OBJECTIVE: Evaluate the safety profile of single- and multilevel cervical artificial disc replacement (ADR) performed in an outpatient setting. SUMMARY OF BACKGROUND DATA: As healthcare costs rise, attempts are made to perform an increasing proportion of spine surgery in ambulatory surgery centers (ASCs). ASCs are more efficient, economically and functionally. Few studies have published on the safety profile of multilevel cervical ADR. METHODS: We have performed an analysis of all consecutive cervical ADR surgeries that we performed in an ASC over a 9-month period, including multilevel and revision surgery. The pre-, intra-, and postoperative data recorded included age, sex, body mass index, tobacco use, and diabetes; level and procedure, operating room time, estimated blood loss (EBL), and complications; and discharge site, occurrence of reoperation, hospital admission, or any medical complication or infection over a 90-day period. RESULTS: A total of 147 patients underwent 231 treated levels: 71 single-level, 76 multilevel: 69 two-level, 6 three-level, and 1 four-level. Average age was 50 ±â€Š10 years; 71 women, 76 men. None of the patients had insulin-dependent diabetes, 4 were current smokers, and 16 were former smokers. Average body mass index was 26.8 ±â€Š4.6 (range 18-40). Average total anesthesia time was 88 minutes (range 39-168 min). Average EBL was 15 mL (range 5-100 mL). Approximately 90.3% of patients were discharged directly home, 9.7% to an aftercare facility. In the 90-day postoperative period there were zero deaths and two hospital admissions (1.4%)-one for medical complication (0.7%) and one for a surgical site infection (0.7%). CONCLUSION: In this consecutive case series we performed 231 ADRs in 147 patients in the outpatient setting, including multilevel and revision procedures, with 2 minor postoperative complications resulting in hospital unplanned admissions within 90 days. We believe that these procedures are safe to perform in an ASC. An efficient surgical team and careful patient selection criteria are critical in making this possible. LEVEL OF EVIDENCE: 3.


Asunto(s)
Procedimientos Quirúrgicos Ambulatorios/métodos , Vértebras Cervicales/cirugía , Reeemplazo Total de Disco/métodos , Adulto , Procedimientos Quirúrgicos Ambulatorios/efectos adversos , Estudios de Cohortes , Femenino , Hospitalización/tendencias , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/etiología , Estudios Retrospectivos , Reeemplazo Total de Disco/efectos adversos
16.
Int J Spine Surg ; 14(4): 483-487, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-32986567

RESUMEN

BACKGROUND: Describe the technique and outcomes of the conversion of prior anterior cervical discectomy and fusion (ACDF) with pseudarthrosis to an artificial disc replacement (ADR). METHODS: Case report. Five patients completed the following pain and function questionnaires at baseline and postoperatively: visual analog pain scale (VAS), Neck Disability Index (NDI), PROMIS Emotional Distress-Depression Short Form-4a (P-EDD), PROMIS Pain Interference Short Form 6b (P-PI), and PROMIS Physical Function Short Form-10a (P-SF). Pseudarthrosis was diagnosed using computed tomography imaging of the cervical spine. The level of prior fusion with pseudarthrosis was remobilized after a standard anterior approach was made, and an artificial disc replacement was performed after revision discectomy. RESULTS: The conversion of fusion to ADR was successful in all 5 patients without intraoperative or postoperative complication or the need to perform revision fusion. The average follow-up duration was 12.4 months (range 6-24months). VAS improved on average (median) from 6 (6.0) to 2 (2.2), NDI improved from 23 (21) to 15 (17), P-EDD 4a improved from 11 (11) to 4 (4), and P-PI and P-SF improved from 23 (22) to 16 (19) and from 37 (35) to 41 (39.5), respectively. Radiographic range of motion increased at the fusion conversion level from an average of 1° ± 1.2° to 8.1° ± 4.6° after the insertion of the artificial disc replacement. CONCLUSIONS: The reversal of ACDF and conversion to an artificial disc replacement is feasible and achieves postoperative range of motion that is similar to that achieved when performed in a segment not previously fused.

17.
J Neurosurg Spine ; : 1-10, 2020 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-32168483

RESUMEN

OBJECTIVE: The authors sought to assess the impact of heterotopic ossification (HO) on clinical outcomes and angular range of motion (ROM) after cervical disc arthroplasty (CDA) performed with the Prestige LP Cervical Disc (Prestige LP disc) at 2 levels. METHODS: HO was assessed and graded from 0 to IV for increasing severity on lateral neutral radiographs at each visit in 209 patients who underwent implantation of Prestige LP discs at 2 cervical levels in a clinical trial with extended 10-year follow-up. ROM was compared by using HO grade, and clinical outcomes were compared between HO subgroups (grade 0-II vs III/IV) based on HO severity at 2 and 10 years after surgery. RESULTS: The grade III/IV HO incidence at either or both index levels was 24.2% (48/198) at 2 years and 39.0% (57/146) at 10 years. No statistical difference was found in overall success; neurological success; or Neck Disability Index (NDI), neck pain, arm pain, or SF-36 Physical Component Summary (PCS) scores between the HO subgroups (grade 0-II vs III/IV) at either 2 or 10 years. The cumulative rate of possible implant-related adverse events (AEs) was higher in patients having grade III/IV HO at 2 years (56.3%) and 10 years (47.8%) compared with those having grade 0-II HO at 2 years (24.4%) and 10 years (17.9%), specifically in 2 subcategories: spinal events and HOs reported by the investigators. No statistical difference was found between the HO subgroups in possible implant-related serious AEs or secondary surgeries at the index or adjacent levels. The average angular ROMs at index levels were lower in subjects with higher-grade HO at 2 and 10 years. The average ROMs at the superior level were 8.8°, 6.6°, 3.2°, and 0.3°, respectively, for the HO grade 0/I, II, III, and IV groups at 10 years, and 7.9°, 6.2°, 3.7°, and 0.6°, respectively, at the inferior level. CONCLUSIONS: Radiographically severe (grade III or IV) HO after CDA with the Prestige LP disc at 2 levels did not significantly affect efficacy or safety outcomes (severe AEs or secondary surgeries). However, severe HO, particularly grade IV HO, significantly limited ROM, as expected.

18.
Clin Spine Surg ; 33(9): 339-344, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32991361

RESUMEN

STUDY DESIGN: This was a post hoc analysis of a prospective FDA-IDE study. OBJECTIVE: The purpose of this study is to determine the effectiveness of a 2-level anterior cervical discectomy and fusion (ACDF) or cervical disk arthroplasty (CDA) at relieving headaches associated with cervical radiculopathy or myelopathy at 10 years postoperative. BACKGROUND: To our knowledge, there is no large, prospective study that has examined the efficacy of cervical spine surgery for relieving headaches associated with radiculopathy or myelopathy at 10 years postoperative. MATERIALS AND METHODS: This was a post hoc analysis of a prospective FDA-IDE study for the Prestige LP versus ACDF for radiculopathy or myelopathy due to 2 levels. Preoperatively and out to 10 years, their Neck Disability Index documented if they had headaches (0: no headaches; 1: infrequent slight; 2: infrequent moderate; 3: frequent moderate; 4: frequent severe; 5: nearly constant). RESULTS: Three hundred ninety-seven patients were randomized to CDA (209) or ACDF (188). Preoperatively 86% had headaches and 55.9% (52.2% of CDA, 60.1% of ACDFs) had frequent moderate, severe, or nearly constant headache (grades 3-5). By 6 weeks postoperative, 64.4% had headaches and only 12.5% had grades 3-5 headaches (9.3% of CDA and 16% of ACDFs). The benefit lasted to the 10-year follow-up such that 60.3% had any headaches and 16.8% had grades 3-5 headaches (10.9% CDA; 24.3% ACDF). CONCLUSIONS: These results suggest that 86% of patients with radiculopathy or myelopathy complain of headaches preoperatively, with 55.9% having frequent or constant, moderate to severe headaches (grades 3-5). By 6 weeks postoperative, only 12.5% had grades 3-5 headaches. At 10-year follow-up, 16.8% had grades 3-5 headaches. Both arthroplasty and ACDF are often effective at alleviating headaches associated with radiculopathy or myelopathy.


Asunto(s)
Degeneración del Disco Intervertebral , Cefalea Postraumática , Fusión Vertebral , Reeemplazo Total de Disco , Artroplastia , Vértebras Cervicales/cirugía , Discectomía , Estudios de Seguimiento , Humanos , Degeneración del Disco Intervertebral/cirugía , Estudios Prospectivos , Resultado del Tratamiento
19.
J Neurosurg Spine ; 33(6): 727-733, 2020 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-32736353

RESUMEN

Cervical spondylosis is one of the most commonly treated conditions in neurosurgery. Increasingly, cervical disc replacement (CDR) has become an alternative to traditional arthrodesis, particularly when treating younger patients. Thus, surgeons continue to gain a greater understanding of short- and long-term complications of arthroplasty. Here, the authors present a series of 4 patients initially treated with Mobi-C artificial disc implants who developed postoperative neck pain. Dynamic imaging revealed segmental kyphosis at the level of the implant. All implants were locked in the flexion position, and all patients required reoperation. This is the first reported case series of symptomatic segmental kyphosis after CDR.

20.
J Neurosurg Spine ; : 1-11, 2019 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-31226684

RESUMEN

OBJECTIVE: The authors assessed the 10-year clinical safety and effectiveness of cervical disc arthroplasty (CDA) to treat degenerative cervical spine disease at 2 adjacent levels compared to anterior cervical discectomy and fusion (ACDF). METHODS: A prospective, randomized, controlled, multicenter FDA-approved clinical trial was conducted comparing the low-profile titanium ceramic composite-based Prestige LP Cervical Disc (n = 209) at two levels with ACDF (n = 188). Ten-year follow-up data from a postapproval study were available on 148 CDA and 118 ACDF patients and are reported here. Clinical and radiographic evaluations were completed preoperatively, intraoperatively, and at regular postoperative follow-up intervals for up to 10 years. The primary endpoint was overall success, a composite variable that included key safety and efficacy considerations. Ten-year follow-up rates were 86.0% for CDA and 84.9% for ACDF. RESULTS: From 2 to 10 years, CDA demonstrated statistical superiority over ACDF for overall success, with rates at 10 years of 80.4% versus 62.2%, respectively (posterior probability of superiority [PPS] = 99.9%). Neck Disability Index (NDI) success was also superior, with rates at 10 years of 88.4% versus 76.5% (PPS = 99.5%), as was neurological success (92.6% vs 86.1%; PPS = 95.6%). Improvements from preoperative results in NDI and neck pain scores were consistently statistically superior for CDA compared to ACDF. All other study effectiveness measures were at least noninferior for CDA compared to ACDF through the 10-year follow-up period, including disc height. Mean angular ranges of motion at treated levels were maintained in the CDA group for up to 10 years. The rates of grade IV heterotopic ossification (HO) at the superior and inferior levels were 8.2% and 10.3%, respectively. The rate of severe HO (grade III or IV) did not increase significantly from 7 years (42.4%) to 10 years (39.0%). The CDA group had fewer serious (grade 3-4) implant-related or implant/surgical procedure-related adverse events (3.8% vs 8.1%; posterior mean 95% Bayesian credible interval [BCI] of the log hazard ratio [LHR] -0.92 [-1.88, -0.01]). The CDA group also had statistically fewer secondary surgical procedures at the index levels (4.7%) than the ACDF group (17.6%) (LHR [95% BCI] -1.39 [-2.15, -0.61]) as well as at adjacent levels (9.0% vs 17.9%). CONCLUSIONS: The Prestige LP Cervical Disc, implanted at two adjacent levels, maintains improved clinical outcomes and segmental motion 10 years after surgery and is a safe and effective alternative to fusion.Clinical trial registration no.: NCT00637156 (clinicaltrials.gov).

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA