Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Asunto de la revista
País de afiliación
Intervalo de año de publicación
1.
J Radiol Prot ; 38(3): 1013-1036, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29786616

RESUMEN

PURPOSE: Definition of new national diagnostic reference levels (DRLs) for volume computed tomography dose index (CTDIvol) and dose length product (DLP) for neuro-paediatric CT examinations depending on the medical indication. METHODS: Paediatric cranial CT data sets acquired between January 2013 and December 2016 were retrospectively collected between July 2016 and March 2017 from eight of the largest university and cantonal hospitals that perform most of the neuro-paediatric CTs in Switzerland. A consensus review of CTDIvol and DLP was undertaken for three defined anatomical regions: brain, facial bone, and petrous bone, each with and without contrast medium application. All indications for cranial CT imaging in paediatrics were assigned to one of these three regions. Descriptive statistical analysis of the distribution of the median values for CTDIvol and DLP yielded values in the minimum, maximum, 25th percentile (1st quartile), median (2nd quartile), and 75th percentile (3rd quartile). New DRLs for neuro-paediatric CT examinations in Switzerland were based on the 75th percentiles of the distributions of the median values of all eight centres. Where appropriate, values were rounded such that the DRLs increase or at least remain constant as the age of the patient increases. RESULTS: Our results revealed DRLs for CTDIvol and DLP up to 20% lower than the DRLs used so far in Switzerland and elsewhere in Europe. CONCLUSIONS: This study provides Swiss neuro-paediatric CT DRL values to establish optimum conditions for paediatric cranial CT examinations. Periodic national updates of DRLs, following international comparisons, are essential.


Asunto(s)
Encéfalo/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Adolescente , Niño , Preescolar , Humanos , Lactante , Recién Nacido , Dosis de Radiación , Valores de Referencia , Estudios Retrospectivos
2.
Radiat Prot Dosimetry ; 169(1-4): 221-4, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26541187

RESUMEN

In 2013, a nationwide investigation was conducted in Switzerland to establish the population's exposure from medical X rays. A hybrid approach was used combining the Raddose database accessible on-line by the participating practices and the Swiss medical tariffication system for hospitals. This study revealed that the average annual number of examinations is 1.2 per inhabitant, and the associated annual effective dose is 1.4 mSv. It also showed that computed tomography is the most irradiating modality and that it delivers 70 % of the total dose. The annual effective dose per inhabitant registered a 17 % increase in 5 y and is comparable with what was recently reported in neighbouring countries.


Asunto(s)
Exposición a Riesgos Ambientales/análisis , Monitoreo de Radiación/métodos , Radiografía/efectos adversos , Radiografía/estadística & datos numéricos , Tomografía Computarizada por Rayos X/métodos , Bases de Datos Factuales , Humanos , Proyectos Piloto , Dosis de Radiación , Radiografía Intervencional/efectos adversos , Radiografía Intervencional/estadística & datos numéricos , Suiza , Rayos X