Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Wien Med Wochenschr ; 173(9-10): 227-231, 2023 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-37071301

RESUMEN

Gastric cancers are relativ commonly cancer types. The therapy options have changed in the last years as well in the surgery as in the oncology, it is worth to look at the etiology, diagnosis and therapy.


Asunto(s)
Neoplasias Gástricas , Humanos , Neoplasias Gástricas/diagnóstico , Neoplasias Gástricas/cirugía , Biopsia , Gastroscopía
2.
Surg Endosc ; 34(12): 5346-5353, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-31907661

RESUMEN

BACKGROUND: Mechanical stimulation of the stretch receptors of the gastric wall can simulate the presence of indigested food leading to reduced food intake. We report the preliminary experimental results of an innovative concept of localized mechanical gastric stimulation. METHODS: In a first survival study, a biocompatible bulking agent was injected either in the greater curvature (n = 8) or in the cardia wall (n = 8) of Wistar rats. Six animals served as sham. Changes of bulking volume, leptin levels and weight gain were monitored for 3 months. In a second acute study, a micro-motor (n = 10; MM) or a size-paired inactive device (n = 10; ID) where applied on the cardia, while 10 additional rats served as sham. Serum ghrelin and leptin were measured at baseline and every hour (T0-T1-T2-T3), during 3 h. In a third study, 24 implants of various shapes and sizes were introduced into the gastric subserosa of 6 Yucatan pigs. Monthly CT scans and gastroscopies were done for 6 months. RESULTS: Weight gain in the CW group was significant lower after 2 weeks and 3 months when compared to the shame and GC (p = 0.01/p = 0.01 and p = 0.048/p = 0.038 respectively). Significant lower increase of leptin production occurred at 2 weeks (p = 0.01) and 3 months (p = 0.008) in CW vs. SG. In the MM group significant reduction of the serum ghrelin was seen after 3 h. Leptin was significantly increased in both MM and ID groups after 3 h, while it was significantly reduced in sham rats. The global device retention was 43.5%. Devices with lower profile and with a biocompatible coating remained more likely in place without complications. CONCLUSIONS: Gastric mechanical stimulation induced a reduced weight gain and hormonal changes. Low profile and coated devices inserted within the gastric wall are more likely to be integrated.


Asunto(s)
Apetito/fisiología , Tracto Gastrointestinal/fisiopatología , Animales , Femenino , Masculino , Prueba de Estudio Conceptual , Ratas , Ratas Wistar , Porcinos
3.
Surg Innov ; 26(3): 280-292, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30920898

RESUMEN

PURPOSE: Targeted embolization of gastrointestinal (GI) arteries can modify hormonal production. We aimed to evaluate the impact of the embolization of the gastroduodenal artery (GDA) on the activity of foregut mucosa. METHODS: The GDA's duodenal branch was embolized in 12 Yucatan pigs using 100-300 µm (group A; n = 4) or 300-500 µm (group B; n = 4) microspheres, followed by coiling of the branch. In 4 animals (sham), only saline was injected. The levels of GI hormones (ghrelin, glucose-dependent insulinotropic peptide [GIP], glucagon-like peptide-1 [GLP-1], insulin, peptide YY [PYY], leptin) and the gene expression of sodium-glucose-linked transporter-1 (SGLT-1) and glucose transporter-2 (GLUT-2) were assessed before (T0), 1 hour (T1), 1 month (T2), 3 months (T3), and 6 months (T4) after embolization. RESULTS: In group A, a segmental duodenal stenosis occurred in all cases, which required balloon dilatation. There was a significant drop in the baseline glycemia in group A at T1 and T4 versus sham. Ghrelin was reduced in group A versus baseline and versus group B at T2 and T3 and versus sham at T1 and T3. Insulin was significantly lower in group A versus B at T1 and at T4 but not versus sham. SGLT-1 expression increased in B and sham at T4, while it remained stable in group A. GLUT-2 expression increased in sham at T4 but not in A or B. CONCLUSIONS: GDA embolization induced a decrease in ghrelin production and influenced expression of glucose carriers in the foregut mucosa.


Asunto(s)
Duodeno , Embolización Terapéutica , Hormonas Gastrointestinales , Síndrome Metabólico , Animales , Masculino , Angiografía de Substracción Digital , Medios de Contraste/administración & dosificación , Modelos Animales de Enfermedad , Duodeno/irrigación sanguínea , Duodeno/diagnóstico por imagen , Embolización Terapéutica/métodos , Hormonas Gastrointestinales/metabolismo , Mucosa Intestinal/metabolismo , Síndrome Metabólico/metabolismo , Síndrome Metabólico/prevención & control , Porcinos , Ácidos Triyodobenzoicos/administración & dosificación
4.
Surg Endosc ; 32(7): 3215-3224, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29330589

RESUMEN

BACKGROUND: Standard insufflators compensate for intra-abdominal pressure variations with pressure spikes. Our aim was to evaluate the impact of a stable, low-pressure pneumoperitoneum induced by a valve-less insufflator, on working space, hemodynamics, inflammation, and peritoneal physiology, in a model of laparoscopic sigmoid resection. MATERIALS AND METHODS: Twelve pigs (47 ± 3.3 kg) were equipped for invasive hemodynamic monitoring and randomly assigned to Standard (n = 6) vs. valve-less (n = 6) insufflation. Animals were positioned in a 30° Trendelenburg on a CT scan bed. A low-pressure pneumoperitoneum (8 mmHg) was started and duration was set for 180 min. Abdominal CT scans were performed, under neuromuscular blockade, before, immediately after, and 1 and 3 h after insufflation. Pneumoperitoneum volumes were calculated on 3D reconstructed CT scans. After creation of a mesenteric window, capillary blood was obtained by puncturing the sigmoid serosa and local lactatemia (mmol/L) was measured using a handheld analyzer. Surgical resection was performed according to the level of lactates, in order to standardize bowel stump perfusion. IL-1 and IL-6 (ng/mL) were measured repeatedly. The peritoneum was sampled close to the surgical site and distantly for the oxygraphic assessment of mitochondrial respiration. A pathologist applied a semi-quantitative score to evaluate the anastomosis. RESULTS: Mean arterial pressure, pulse, body temperature, oximetry, systemic lactatemia, and local lactates were similar. IL-6 was lower in the valve-less group, reaching a statistically significant difference after 3 h of insufflation (64.85 ± 32.5 vs. 133.95 ± 59.73; p = 0.038) and 48 h (77.53 ± 68.4 vs. 190.74 ± 140.79; p = 0.029). Peritoneal mitochondrial respiration was significantly increased after the survival period, with no difference among the groups. The anastomoses in the valve-less group demonstrated a lower acute (p = 0.04) inflammatory infiltration. The mean anterior posterior thickness was slightly, yet significantly higher in the valve-less group, on all post-insufflation CT scans. CONCLUSIONS: Valve-less insufflation achieved a slightly higher working space and a lower systemic and localized inflammatory response in this experimental setting.


Asunto(s)
Colon Sigmoide/cirugía , Insuflación/instrumentación , Laparoscopía , Neumoperitoneo Artificial , Pared Abdominal/diagnóstico por imagen , Anastomosis Quirúrgica , Animales , Respiración de la Célula , Imagenología Tridimensional , Interleucina-1/sangre , Interleucina-6/sangre , Mitocondrias/metabolismo , Modelos Animales , Peritoneo/metabolismo , Peritoneo/patología , Radiografía Abdominal , Porcinos , Tomografía Computarizada por Rayos X
5.
Surg Endosc ; 31(3): 1451-1460, 2017 03.
Artículo en Inglés | MEDLINE | ID: mdl-27495341

RESUMEN

BACKGROUND: Intraoperative liver segmentation can be obtained by means of percutaneous intra-portal injection of a fluorophore and illumination with a near-infrared light source. However, the percutaneous approach is challenging in the minimally invasive setting. We aimed to evaluate the feasibility of fluorescence liver segmentation by superselective intra-hepatic arterial injection of indocyanine green (ICG). MATERIALS AND METHODS: Eight pigs (mean weight: 26.01 ± 5.21 kg) were involved. Procedures were performed in a hybrid experimental operative suite equipped with the Artis Zeego®, multiaxis robotic angiography system. A pneumoperitoneum was established and four laparoscopic ports were introduced. The celiac trunk was catheterized, and a microcatheter was advanced into different segmental hepatic artery branches. A near-infrared laparoscope (D-Light P, Karl Storz) was used to detect the fluorescent signal. To assess the correspondence between arterial-based fluorescence demarcation and liver volume, metallic markers were placed along the fluorescent border, followed by a 3D CT-scanning, after injecting intra-arterial radiological contrast (n = 3). To assess the correspondence between arterial and portal supplies, percutaneous intra-portal angiography and intra-arterial angiography were performed simultaneously (n = 1). RESULTS: Bright fluorescence signal enhancing the demarcation of target segments was obtained from 0.1 mg/mL, in matter of seconds. Correspondence between the volume of hepatic segments and arterial territories was confirmed by CT angiography. Higher background fluorescence noise was found after positive staining by intra-portal ICG injection, due to parenchymal accumulation and porto-systemic shunting. CONCLUSIONS: Intra-hepatic arterial ICG injection, rapidly highlights hepatic target segment borders, with a better signal-to-background ratio as compared to portal vein injection, in the experimental setting.


Asunto(s)
Angiografía/métodos , Colorantes , Colorantes Fluorescentes , Arteria Hepática/diagnóstico por imagen , Verde de Indocianina , Hígado/diagnóstico por imagen , Imagen Óptica/métodos , Animales , Estudios de Factibilidad , Rayos Infrarrojos , Inyecciones Intraarteriales , Cuidados Intraoperatorios/métodos , Hígado/irrigación sanguínea , Vena Porta , Coloración y Etiquetado , Sus scrofa , Porcinos
6.
Ann Surg Oncol ; 23(Suppl 5): 567-573, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-26511264

RESUMEN

BACKGROUND: Tumor-specific fluorescent antibodies, which can be recognized at a cellular or tissue level using optical imaging such as confocal laser endomicroscopy (CLE), could provide a means for rapid and accurate tumor diagnosis and staging. The aim of this study was to evaluate the ability of CLE to detect the presence of tagged cells within lymph nodes in an original simulated metastatic model. MATERIALS AND METHODS: A solution of indocyanine green containing a suspension of porcine hepatocytes, marked with carboxy-fluorescein-succinimidyl-ester (CFSE), was injected endoscopically in the gastric submucosa of 10 pigs. Fluorescence lymphography using a near-infrared laparoscope was used to identify sentinel and secondary drainage nodes. Additionally, a nonfluorescent gastric and a mesenteric node were identified. Every 5-10 min, those nodes were scanned using probe-based or needle-based CLE (pCLE or nCLE). Immunohistochemistry (IHC) using anti-cytokeratin 18 antibodies was subsequently performed to confirm the presence of hepatocytes in the lymph nodes. RESULTS: A total of 36 lymph nodes were analyzed with both CLE probes. Hepatocyte penetration in lymph nodes, as assessed by repeated CLE scanning, took 10-40 min after submucosal injection. Concordance between CLE and IHC was 84 and 72 % for pCLE and nCLE, respectively. False negatives were partly due to incomplete CFSE labeling of hepatocytes, which could not be recognized by CLE, but were detected with IHC. CONCLUSIONS: Real-time CLE analysis effectively recognized the presence in perigastric nodes of marked hepatic cells that had been injected endoscopically in the stomach. Validation studies on tumor-bearing animals using tumor-specific antibodies should be performed.


Asunto(s)
Inmunohistoquímica/métodos , Ganglio Linfático Centinela/diagnóstico por imagen , Ganglio Linfático Centinela/patología , Animales , Anticuerpos , Colorantes , Femenino , Mucosa Gástrica , Hepatocitos/inmunología , Verde de Indocianina , Queratina-18/inmunología , Laparoscopía/métodos , Metástasis Linfática , Masculino , Mesenterio , Microscopía Confocal/métodos , Modelos Biológicos , Prueba de Estudio Conceptual , Porcinos
7.
Surg Endosc ; 30(5): 2143-50, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-26275550

RESUMEN

BACKGROUND: Despite intensive preoperative localization workouts, intraoperative localization of the bleeding source in case of obscure gastrointestinal bleeding (OGIB) can be cumbersome and time-consuming. Our aim was to assess the feasibility of image-guided laparoscopic identification of the small bowel loop containing the bleeding source with and without near-infrared angiographic enhancement. MATERIALS AND METHODS: Angiography of superior mesenteric artery (SMA) branches was performed in 11 pigs using a right femoral artery approach, followed by a three-port laparoscopy, using a near-infrared-equipped laparoscope. Two pigs were used to identify the optimal intra-arterial indocyanine green (ICG) dose. Eight pigs were divided into two groups: ICG near-infrared angiography-assisted laparoscopy (n = 4) and fluoroscopic-assisted laparoscopy (n = 4). Finally, in one pig, a novel OGIB model was created and used to evaluate the ICG enhancement pattern in the presence of active bleeding. RESULTS: Mean time to identify the fluorescence signal from the small bowel segment fed by the catheterized SMA branch was 13.75 ± 7.8 s, which was statistically significantly shorter than the time required to identify the tip of the catheter by fluoroscopic guidance, i.e., 243.25 ± 107 s (p = 0.02). CONCLUSIONS: Near-infrared fluorescence angiography using intra-arterial ICG injection provides a fast image-guided intraoperative localization of the small bowel loop fed by the arterial territory identified as bleeding by digital subtraction angiography and could help target the bleeding source during OGIB surgery.


Asunto(s)
Colorantes/farmacología , Modelos Animales de Enfermedad , Angiografía con Fluoresceína , Hemorragia Gastrointestinal/diagnóstico por imagen , Verde de Indocianina/farmacología , Animales , Femenino , Angiografía con Fluoresceína/instrumentación , Hemorragia Gastrointestinal/patología , Masculino , Imagen Óptica , Porcinos , Procedimientos Quirúrgicos Vasculares
8.
Surg Endosc ; 30(4): 1683-91, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26150225

RESUMEN

BACKGROUND: Current surgical methods for partial gastric full-thickness resections (FTRs) are limited by long operative times and risk of gastric content spillage, especially for lesions located at the posterior wall. We propose a simplified hybrid approach to FTR with reduced risk of spillage. METHODS: Resection margins were marked by endoscopic electrocautery to simulate a gastric lesion in the upper third of the posterior wall in eight pigs. A custom-made laparoscopic "suture passer" was made of a sharpened bendable dissecting forceps. Full-thickness sutures were alternatively passed from the serosa side with the suture passer through the gastric wall and grabbed endoluminally using an endoscopic grasper and vice versa. These transgastric sutures formed either a purse string (PS; n = 4) or a continuous horizontal mattress (HM; n = 4). Sutures were then fastened from the laparoscopic side, resulting in external outpouching of the lesion. The pouch was transected using 45-mm linear staplers. Operative time, resection margins, and number of staplers were evaluated. RESULTS: The combined approach allowed one to precisely place the sutures around the pseudo lesions, despite the inflated stomach, and it included all target markings. PS and HM methods were similar regarding time for transgastric suture (780 s ± 219.1 s vs. 765 s ± 179.2 s, p = .885), resection margins (1.3 ± 1.0 cm vs. 0.8 ± 0.6 cm, p = .248), and number of staplers (3.8 ± 1.0 vs 3.3 ± 0.5, p = .405). Stapling time (600 s ± 189.7 s vs. 330 s ± 24.5 s, p = .028) was significantly shorter in the HM technique. CONCLUSION: FTR with laparo-endoscopic transgastric suture application was feasible in the animal model. This technique allows one to achieve accurate resection margins with minimal risk of spillage.


Asunto(s)
Gastrectomía/métodos , Gastroscopía/métodos , Laparoscopía/métodos , Neoplasias Gástricas/cirugía , Animales , Femenino , Modelos Animales , Sus scrofa , Técnicas de Sutura , Suturas , Porcinos
9.
Surg Endosc ; 30(7): 3128-32, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-26487207

RESUMEN

INTRODUCTION: Bile leakage is a serious complication occurring in up to 10 % of hepatic resections. Intraoperative detection of bile leakage is challenging, and concomitant blood oozing can mask the presence of bile. Intraductal dye injection [methylene blue or indocyanine green (ICG)] is a validated technique to detect bile leakage. However, this method is time-consuming, particularly in the laparoscopic setting. A novel narrow band imaging (NBI) modality (SPECTRA-A; Karl Storz, Tuttlingen, Germany) allows easy discrimination of the presence of bile, which appears in clear orange, by image processing. The aim of this experimental study was to evaluate SPECTRA-A ability to detect bile leakage. METHODS: Twelve laparoscopic partial hepatectomies were performed in seven pigs. The common bile duct was clipped distally and dissected, and a catheter was inserted and secured with a suture or a clip. Liver dissection was achieved with an ultrasonic cutting device. Dissection surfaces were checked by frequently switching on the SPECTRA filter to identify the presence of bile leakage. Intraductal ICG injection through the catheter was performed to confirm SPECTRA findings. RESULTS: Three active bile leakages were obtained out of 12 hepatectomies and successfully detected intraoperatively by the SPECTRA. There was complete concordance between NBI and ICG fluorescence detection. No active leaks were found in the remaining cases with both techniques. The leaking area identified was sutured, and SPECTRA was used to assess the success of the repair. CONCLUSIONS: The SPECTRA laparoscopic image processing system allows for rapid detection of bile leaks following hepatectomy without any contrast injection.


Asunto(s)
Bilis/diagnóstico por imagen , Hepatectomía/efectos adversos , Laparoscopía/métodos , Hepatopatías/diagnóstico por imagen , Imagen de Banda Estrecha/métodos , Animales , Conducto Colédoco/diagnóstico por imagen , Modelos Animales de Enfermedad , Procesamiento de Imagen Asistido por Computador , Hepatopatías/etiología , Sus scrofa , Porcinos
10.
Surg Endosc ; 30(9): 4115-23, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-26511116

RESUMEN

BACKGROUND: Biliary injuries remain a major concern in laparoscopic cholecystectomy. New intraoperative guidance modalities, including near-infrared fluorescence cholangiography, are under evaluation. Initial results showed limitations in visualizing the biliary tree in specific clinical situations. The aim of this study was to examine the feasibility and potentiality of fluorescence cholecysto-cholangiography performed with a direct injection of indocyanine green (ICG) in the gallbladder and to compare it to systemic injection in such situations. MATERIALS AND METHODS: Seven pigs were included in this non-survival study. In two pigs, the gallbladder was punctured by a percutaneous needle, and 1 mL of ICG in different concentrations (0.001, 0.01, 0.1, and 1 mg/mL) was sequentially injected. Visibility and pattern of the fluorescent signal around Calot's triangle were examined and compared with those of two control pigs receiving 2.5 mg of intravenous ICG, 30 min prior to the operation. Different scenarios of cholecystitis were modeled using an injection of a mixture of blood and agarose gel around Calot's triangle area in the remaining three pigs, and the applicability of direct intragallbladder injection methods was evaluated. RESULTS: The fluorescent signal was identified immediately after intragallbladder injection, and the cystic duct became visible by 0.1 and 1 mg/mL of ICG. The whole cystic duct and the infundibulum of the gallbladder were clearly enhanced by intragallbladder ICG injection, but not by systemic injection. In the cholecystitis models, the cystic duct could be identified only after partial dissection, and fluorescence visualization of the gallbladder infundibulum provided crucial information to find the correct starting point of dissection. CONCLUSIONS: Fluorescence cholecysto-cholangiography through direct intragallbladder ICG injection could rapidly provide an adequate visualization of gallbladder neck and cystic duct and might be a valid option to increase the safety of cholecystectomy in case of cholecystitis.


Asunto(s)
Colangiografía/métodos , Colecistectomía Laparoscópica/métodos , Colecistitis/cirugía , Colecistografía/métodos , Colorantes , Conducto Cístico/diagnóstico por imagen , Vesícula Biliar/diagnóstico por imagen , Verde de Indocianina , Cirugía Asistida por Computador/métodos , Animales , Sistema Biliar/diagnóstico por imagen , Fluorescencia , Imagen Óptica/métodos , Espectroscopía Infrarroja Corta , Sus scrofa , Porcinos
11.
Surg Innov ; 23(3): 221-8, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26989046

RESUMEN

Background Fistulas after esophagectomy are a significant cause of morbidity and mortality. Several endoscopic treatments have been attempted, with varying success. An experimental model that could validate new approaches such as cellular therapies is highly desirable. The aim of this study was to create a chronic esophageal enterocutaneous fistula model in order to study future experimental treatment options. Methods Eight pigs (six 35-kg young German and two 50-kg adult Yucatan pigs) were used. Through a left and right cervicotomy, under endoscopic view, 1 (group A, n = 6) or 2 (group B, n = 7) plastic catheters were introduced into the esophagus 30 cm from the dental arches bilaterally and left in place for 1 month. Radiologic and endoscopic fistula tract evaluations were performed at postoperative day (POD; 30) and at sacrifice (POD 45). Results Three fistulas were excluded from the study because of early (POD 5) dislodgment of the catheter, with complete fistula closure. At catheter removal (POD 30), the external orifice was larger in group B (5.2 ± 1.1 mm vs 2.6 ± 0.4 mm) with more severe inflammation (72% vs 33%). At POD 45, the external orifice was closed in all fistulas in group A and in 1/7 in group B. At necropsy, the fistula tract was still present in all animals. Yucatan pigs showed more complex tracts, with a high level of necrosis and substantial fibrotic infiltration. Conclusions In this article, we show a reproducible, safe, and effective technique to create an esophagocutaneous fistula model in a large experimental animal.


Asunto(s)
Fístula Cutánea/cirugía , Fístula Esofágica/cirugía , Esofagectomía/efectos adversos , Esofagoscopía/métodos , Animales , Biopsia con Aguja , Fístula Cutánea/patología , Modelos Animales de Enfermedad , Fístula Esofágica/patología , Esofagectomía/métodos , Inmunohistoquímica , Reproducibilidad de los Resultados , Porcinos
12.
Surg Endosc ; 29(11): 3367-72, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25631112

RESUMEN

BACKGROUND AND STUDY AIMS: Endoscopic suturing reduces stent migration, but is challenging and time-consuming. We compare endoscopic suturing versus anchoring with a novel over-the-scope clip (Padlock) to fix esophageal stents. Additionally, the first clinical case of Padlock stent fixation is reported. MATERIALS AND METHODS: A fully covered esophageal stent was placed in 11 pigs and fixed with one figure-of-eight suture (n = 5) or with a Padlock (n = 4) or not fixed (controls; n = 2). The force required to mobilize the stent was recorded. CLINICAL CASE: an esophageal stent was fixed with a Padlock and endoscopically removed 1 month later, in an 82-year-old patient. RESULTS: Mean force (newton) to mobilize the stent was similar after suturing and Padlock fixation (23.99 ± 14.91 vs. 19.97 ± 7.62; p = 0.32). In controls was 7 and 11 Newtons. Suturing time (seconds) was longer than Padlock application (455.4 ± 144.83 vs. 155 ± 12.9; p = 0.002). CLINICAL CASE: stent fixation was feasible and uncomplicated. Removal was easy, and only mild bleeding occurred. CONCLUSIONS: Padlock is faster than endoscopic suturing and achieves similar stent fixation. The first clinical case confirms the feasibility of the method.


Asunto(s)
Esofagoscopía/instrumentación , Esófago/cirugía , Stents , Técnicas de Sutura , Anciano de 80 o más Años , Animales , Esofagoscopios , Esofagoscopía/métodos , Humanos , Porcinos
13.
Surg Endosc ; 29(11): 3404-8, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25631115

RESUMEN

BACKGROUND: Treatment of perforations and complications related to gastrointestinal (GI) surgery and interventional flexible endoscopy is increasingly performed endoscopically. New devices enabling secure full-thickness GI tract closures through flexible endoscopic platforms have been recently developed. AIM: To assess feasibility of endoscopic closure of a large gastrotomy using a tip-mounted flexible endoscopic suturing device. METHODS: Six pigs were involved in this study. Standardized 3-cm full-thickness gastrotomies were created endoscopically in various areas of the gastric wall, in all animals, using monopolar cautery. A peritoneoscopy was performed through the gastrotomy. In four pigs, gastrotomy was repaired with an endoscopic suturing device (OverStitch™, Apollo Medical). Full-thickness suturing was started at the edges of the incision, and a figure-of-eight pattern was used. A dedicated helical tissue grasper combined with endoscopic suction was used to retract incision borders and ensure full-thickness closure. Sutures were locked using a cinching device. In two pigs, the gastrotomy was closed laparoscopically and served as a control. An air leak test was performed. On postoperative day 10 (POD 10), all pigs underwent endoscopy and laparotomy and were euthanized. RESULTS: Mean endoscopic suturing time was 57.5 ± 14.15 min, and four to six sutures were delivered per incision. Laparoscopic suturing time was 8 min. All leak tests were negative. No intraoperative or postoperative complications occurred. On POD 10, all gastrotomies were healed. In one animal, thick adhesions were found surrounding the suture site but no leak was identified. CONCLUSIONS: Full-thickness suturing of experimental gastrotomies using the OverStitch™ device is feasible and effective.


Asunto(s)
Gastroscopía , Estómago/cirugía , Técnicas de Sutura/instrumentación , Animales , Diseño de Equipo , Estudios de Factibilidad , Gastroscopía/instrumentación , Gastroscopía/métodos , Laparoscopía , Estómago/lesiones , Porcinos
14.
Surg Endosc ; 29(8): 2402-6, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25414067

RESUMEN

BACKGROUND: Peritoneal dialysis (PD) catheters placed in the pelvic space without anchoring present a high rate of migration. We aimed to assess the feasibility of a single-incision approach, using a flexible endoscopic preperitoneal tunneling for catheter implantation and fixation. MATERIALS AND METHODS: Eight pigs were involved in this experimental study. A 2/0 Vicryl loop was sutured at the tip of a PD catheter. In 4 pigs, a 1.5 cm incision was made on the left paramedian line and the parietal peritoneal layer was identified by splitting rectal muscles. A gastroscope was inserted in the incision and advanced in the extraperitoneal space. An exit hole was made in the peritoneum over the low pelvic cavity. A guidewire was left in the abdominal cavity, and the PD catheter was inserted over the guidewire. The endoscope was inserted in the tunnel again, and endoscopic clips were deployed over the Vicryl loop to fix the catheter. In 4 pigs, the PD catheter was inserted laparoscopically using a two-port approach. The catheter's tip was fixed with laparoscopic clips on the Vicryl loop. A strain test to assess the force required to detach clips was performed using a digital dynamometer. RESULTS: Operative time for flexible endoscopic tunneling was longer when compared to the laparoscopic implant (29.5 ± 4.43 vs. 22.7 ± 2.51 min). Mean force to displace the catheter was similar after flexible endoscopic fixation when compared to laparoscopic clip fixation (5.57 N ± 2.76 vs. 4.15 N ± 1.76). CONCLUSIONS: Flexible endoscopic extraperitoneal tunneling allows for minimally invasive single-incision PD catheter placement and fixation.


Asunto(s)
Catéteres de Permanencia , Endoscopios , Migración de Cuerpo Extraño/prevención & control , Diálisis Peritoneal/instrumentación , Animales , Estudios de Factibilidad , Laparoscopía , Modelos Animales , Peritoneo/cirugía , Porcinos
15.
Surg Innov ; 22(3): 217-22, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25801192

RESUMEN

INTRODUCTION: Image fusion between ultrasound (US) and computed tomography (CT) scan or magnetic resonance can increase operator accuracy in targeting liver lesions, particularly when those are undetectable with US alone. We have developed a modular gel to simulate hepatic solid lesions for educational purposes in imaging and minimally invasive ablation techniques. We aimed to assess the impact of image fusion in targeting artificial hepatic lesions during the hands-on part of 2 courses (basic and advanced) in hepatobiliary surgery. MATERIALS AND METHODS: Under US guidance, 10 fake tumors of various sizes were created in the livers of 2 pigs, by percutaneous injection of a biocompatible gel engineered to be hyperdense on CT scanning and barely detectable on US. A CT scan was obtained and a CT-US image fusion was performed using the ACUSON S3000 US system (Siemens Healthcare, Germany). A total of 12 blinded course attendants, were asked in turn to perform a 10-minute liver scan with US alone followed by a 10-minute scan using image fusion. RESULTS: Using US alone, the expert managed to identify all lesions successfully. The true positive rate for course attendants with US alone was 14/36 and 2/24 in the advanced and basic courses, respectively. The total number of false positives identified was 26. With image fusion, the rate of true positives significantly increased to 31/36 (P < .001) in the advanced group and 16/24 in the basic group (P < .001). The total number of false positives, considering all participants, decreased to 4 (P < .001). CONCLUSIONS: Image fusion significantly increases accuracy in targeting hepatic lesions and might improve echo-guided procedures.


Asunto(s)
Procesamiento de Imagen Asistido por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Ultrasonografía Intervencional/métodos , Animales , Hígado/diagnóstico por imagen , Neoplasias Hepáticas/diagnóstico por imagen , Modelos Biológicos , Fantasmas de Imagen , Porcinos
16.
Surg Innov ; 22(1): 5-14, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25294792

RESUMEN

INTRODUCTION: Selective embolization of the left-gastric artery (LGA) reduces levels of ghrelin and achieves significant short-term weight loss. However, embolization of the LGA would prevent the performance of bariatric procedures because the high-risk leakage area (gastroesophageal junction [GEJ]) would be devascularized. AIM: To assess an alternative vascular approach to the modulation of ghrelin levels and generate a blood flow manipulation, consequently increasing the vascular supply to the GEJ. MATERIALS AND METHODS: A total of 6 pigs underwent a laparoscopic clipping of the left gastroepiploic artery. Preoperative and postoperative CT angiographies were performed. Ghrelin levels were assessed perioperatively and then once per week for 3 weeks. Reactive oxygen species (ROS; expressed as ROS/mg of dry weight [DW]), mitochondria respiratory rate, and capillary lactates were assessed before and 1 hour after clipping (T0 and T1) and after 3 weeks of survival (T2), on seromuscular biopsies. A celiac trunk angiography was performed at 3 weeks. RESULTS: Mean (±standard deviation) ghrelin levels were significantly reduced 1 hour after clipping (1902 ± 307.8 pg/mL vs. 1084 ± 680.0; P = .04) and at 3 weeks (954.5 ± 473.2 pg/mL; P = .01). Mean ROS levels were statistically significantly decreased at the cardia at T2 when compared with T0 (0.018 ± 0.006 mg/DW vs. 0.02957 ± 0.0096 mg/DW; P = .01) and T1 (0.0376 ± 0.008 mg/DW; P = .007). Capillary lactates were significantly decreased after 3 weeks, and the mitochondria respiratory rate remained constant over time at the cardia and pylorus, showing significant regional differences. CONCLUSIONS: Manipulation of the gastric flow targeting the gastroepiploic arcade induces ghrelin reduction. An endovascular approach is currently under evaluation.


Asunto(s)
Cardias/fisiología , Arteria Gastroepiploica/cirugía , Ghrelina/metabolismo , Estómago/irrigación sanguínea , Angiografía , Animales , Arteria Celíaca/diagnóstico por imagen , Arteria Gastroepiploica/diagnóstico por imagen , Ghrelina/análisis , Lactatos/sangre , Masculino , Especies Reactivas de Oxígeno/análisis , Porcinos
17.
Surg Innov ; 21(5): 456-63, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-24623807

RESUMEN

INTRODUCTION: An outpatient transoral endoscopic procedure for gastroesophageal reflux disease (GERD) and obesity would be appealing if safe, effective, and durable. We present the first in human experience with a new system. METHODS: Eight patients with GERD (3) and obesity (5) were selected according to a preapproved study protocol. All GERD patients had preprocedure manometry and pH monitoring to document GERD as well as quality of life and symptom questionnaires. Obese patients (body mass index >35) underwent a psychological evaluation and tests for comorbidities. Under general anesthesia, a procedure was performed at the gastroesophageal junction including mucosal excision, suturing of the excision beds for apposition, and suture knotting. RESULTS: One patient with micrognathia could not undergo the required preprocedural passage of a 60 F dilator and was excluded. The first 2 GERD patients had incomplete procedures due to instrument malfunction. The subsequent 5 subjects had a successfully completed procedure. Four patients were treated for obesity and had an average excess weight loss of 30.3% at 2-year follow-up. Of these patients, one had an 8-mm outlet at the end of the procedure recognized on video review--a correctable error--and another vomited multiple times postoperatively and loosened the gastroplasty sutures. The treated GERD patient had resolution of reflux-related symptoms and is off all antisecretory medications at 2-year follow-up. Her DeMeester score was 8.9 at 24 months. CONCLUSION: The initial human clinical experience showed promising results for effective and safe GERD and obesity therapy.


Asunto(s)
Endoscopía/métodos , Reflujo Gastroesofágico/cirugía , Gastroplastia/instrumentación , Gastroplastia/métodos , Obesidad/cirugía , Unión Esofagogástrica/cirugía , Estudios de Seguimiento , Humanos , Proyectos Piloto
18.
Magy Seb ; 67(5): 304-7, 2014 Oct.
Artículo en Húngaro | MEDLINE | ID: mdl-25327405

RESUMEN

The authors report the case of a 63-year-old patient who was polytraumatized in a motor vehicle accident and suffered multiple traumatic injuries. Chest and pelvic fractures as well as left-sided diaphragmatic rupture with associated omentum herniation were diagnosed on CT scan. None of the injuries required urgent surgical intervention. After 10 days supportive therapy, elective laparoscopic reconstruction of the diaphragmatic hernia was performed. The authors discuss the role of laparoscopic diaphragm reconstruction.


Asunto(s)
Diafragma/lesiones , Diafragma/cirugía , Hernia Diafragmática Traumática/cirugía , Procedimientos de Cirugía Plástica/métodos , Heridas no Penetrantes/cirugía , Accidentes de Tránsito , Hernia Diafragmática Traumática/etiología , Humanos , Laparoscopía , Masculino , Persona de Mediana Edad , Rotura , Resultado del Tratamiento , Heridas no Penetrantes/etiología
19.
Surg Endosc ; 27(3): 927-35, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23052516

RESUMEN

BACKGROUND: A subset of patients requires reoperative antireflux surgery (Re-ARS) after failed fundoplication. The aim of this study was to determine symptomatic outcomes beyond 1 year following Re-ARS and to assess the relative utility of two different surgical approaches. METHODS: After Institutional Review Board approval, patients who underwent Re-ARS were identified from a prospective database. Symptom severity was graded on a 0-3 scale. Patients with postoperative symptoms of grade ≥ 2 were considered to have a poor outcome. Patient satisfaction was graded using a 10-point visual analog scale. RESULTS: At least 1 year of follow-up was available for 130 patients. There were 94 redo fundoplications (RF) and 36 Roux-en-Y reconstructions (RNYR). Symptom risk factors (significant preoperative dysphagia, significant preoperative heartburn, esophageal dysmotility, short esophagus, delayed gastric emptying, multiple failed hiatal surgeries, reflux-related respiratory symptoms) were more prevalent in patients who underwent RNYR compared to RF (mean 3.0 vs. 2.2; p = 0.003). Postoperative leaks and major complications occurred in 4.5 % (5/110) versus 0% and 21.6 % versus 33.3 % of the RF and RNYR groups, respectively. Twenty-eight RF patients (29.8 %) and 9 RNYR patients (25.0 %) reported poor outcomes. Among patients with ≥ 4 risk factors, those who underwent RNYR had a lower incidence of poor outcome (7.7 % vs. 55 %, p = 0.018) and higher satisfaction scores (8.4 vs. 5.8, p = 0.001) compared to those who had RF. Overall, 85 % of patients were satisfied or highly satisfied with their results and the average satisfaction score was 8.2. CONCLUSION: Re-ARS provides good subjective outcomes when measured more than 1 year after surgery. Patients with more complex pathology benefit more from RNYR despite the higher postoperative complication rate. This is especially true for patients with decreased esophageal motility and short esophagus.


Asunto(s)
Anastomosis en-Y de Roux/métodos , Fundoplicación/métodos , Reflujo Gastroesofágico/cirugía , Anastomosis en-Y de Roux/psicología , Femenino , Fundoplicación/psicología , Humanos , Laparoscopía/métodos , Laparoscopía/psicología , Masculino , Persona de Mediana Edad , Satisfacción del Paciente , Complicaciones Posoperatorias/etiología , Estudios Prospectivos , Recurrencia , Reoperación/métodos , Reoperación/psicología , Factores de Riesgo , Resultado del Tratamiento
20.
Surg Innov ; 20(6): 586-93, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23423723

RESUMEN

BACKGROUND: Suture and staple-based endoluminal devices for gastroesophageal reflux disease (GERD) and obesity have failed to demonstrate long-term efficacy. OBJECTIVE: To demonstrate the feasibility of mucosal excision and full-thickness suture apposition of the excision beds to create sufficient scar tissue formation at the gastroesophageal junction for the intraluminal treatment of GERD or obesity. DESIGN: Survival animal experiments. PATIENTS: Seven mongrel dogs. Interventions. Under general endotracheal anesthesia, a Barostat test was performed on 4 dogs. A mucosal excision device was introduced through the esophagus into the proximal stomach. Two to 4 mucosal excisions were performed on all dogs at or just below the gastroesophageal junction and the mucosal pieces were removed. After hemostasis, an intraluminal suturing instrument was introduced and either 2 or 4 sutures were placed through the excision beds to bring them into apposition. These were tied and the suture strands cut. All dogs were survived for 2 months. End-term endoscopies were performed, and a repeat Barostat procedure was performed on the animals undergoing an antireflux procedure. After euthanasia the stomachs were explanted, examined, photographed, and sectioned for histologic examination. RESULTS: All dogs survived without complication. In the 4 GERD dogs, the Barostat studies demonstrated a significant decrease in gastroesophageal junction compliance. In the 3 dogs undergoing the obesity procedure, the gastric outlet apposition to a 6-mm endoscope was satisfactory with full insufflation and the desired scarring was seen on histologic examination. CONCLUSION: It is possible to create adequate gastroesophageal junction scarring for the treatment of GERD and obesity. A clinical pilot study will be initiated.


Asunto(s)
Unión Esofagogástrica/cirugía , Mucosa Gástrica/cirugía , Reflujo Gastroesofágico/cirugía , Obesidad/cirugía , Técnicas de Sutura/instrumentación , Animales , Modelos Animales de Enfermedad , Perros , Endoscopía , Unión Esofagogástrica/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA