RESUMEN
We assessed 45 multifamily buildings (240 apartments) from Finland and 20 (96 apartments) from Lithuania, out of which 37 buildings in Finland and 15 buildings in Lithuania underwent energy retrofits. Building characteristics, retrofit activities, and energy consumption data were collected, and Indoor Air Quality (IAQ) parameters, including carbon monoxide (CO), nitrogen dioxide (NO2 ), formaldehyde (CH2 O), selected volatile organic compounds (benzene, toluene, ethylbenzene, and xylenes (BTEX), radon, and microbial content in settled dust were measured before and after the retrofits. After the retrofits, heating energy consumption decreased by an average of 24% and 49% in Finnish and Lithuanian buildings, respectively. After the retrofits of Finnish buildings, there was a significant increase in BTEX concentrations (estimated mean increase of 2.5 µg/m3 ), whereas significant reductions were seen in fungal (0.6-log reduction in cells/m2 /d) and bacterial (0.6-log reduction in gram-positive and 0.9-log reduction in gram-negative bacterial cells/m2 /d) concentrations. In Lithuanian buildings, radon concentrations were significantly increased (estimated mean increase of 13.8 Bq/m3 ) after the retrofits. Mechanical ventilation was associated with significantly lower CH2 O concentrations in Finnish buildings. The results and recommendations presented in this paper can inform building retrofit studies and other programs and policies aimed to improve indoor environment and health.
Asunto(s)
Contaminantes Atmosféricos/análisis , Contaminación del Aire Interior/análisis , Contaminación del Aire Interior/prevención & control , Conservación de los Recursos Energéticos/métodos , Ventilación , Microbiología del Aire , Polvo/análisis , Ambiente Controlado , Monitoreo del Ambiente , Finlandia , Vivienda , Humanos , Lituania , Ventilación/métodosRESUMEN
BACKGROUND: Driven by climate change mitigation, EU countries are committed to improve energy efficiency of their building stock by implementing the energy performance of buildings directive (EPBD). Should higher energy efficiency result in better indoor environmental quality (IEQ), this policy could also be seen as an opportunity to improve public health across Europe. OBJECTIVES: This paper focuses on the assessment of the effects of energy retrofits on occupant satisfaction with IEQ and health in multifamily buildings. METHODS: Data on occupant satisfaction with IEQ and health were collected from the occupants of 39 Finnish and 15 Lithuanian multifamily buildings (an average of five apartments per building, one adult per apartment) both before and after energy retrofits (such as improving thermal insulation, windows, heating and/or ventilation systems). Parallel to the data collected from the occupants, data on several IEQ parameters, including temperature, temperature factor, and air change rate, were collected from their apartments. Moreover, data from seven Finnish and five Lithuanian non-retrofitted control buildings were collected according to the same protocol. RESULTS: Occupant satisfaction regarding indoor temperature was associated with both retrofit status (OR 5.3, 95% CI 2.6-11.0) and measured IEQ parameters (indoor temperature OR 1.4 per 1⯰C increase, temperature factor OR 1.1 per 1% increase, and air change rate OR 5.6 per 1/h increase). Additional positive associations were found between retrofit status and occupants reporting absence of upper respiratory symptoms (OR 1.8, 95% CI 1.1-2.9) as well as not missing work or school due to respiratory infections (OR 4.1, 95% CI 1.2-13.8), however, these associations were independent of the measured IEQ parameters. CONCLUSIONS: There seems to be a strong subjective component related to the observed changes in occupant satisfaction with IEQ and health as a result of energy retrofitting in buildings. Further studies are needed to verify the actual mechanisms, as well as possible long term effects.
Asunto(s)
Contaminación del Aire Interior/análisis , Conservación de los Recursos Energéticos , Vivienda , Satisfacción Personal , Adulto , Ambiente Controlado , Salud Ambiental , Femenino , Finlandia/epidemiología , Humanos , Lituania/epidemiología , Masculino , Enfermedades Respiratorias/epidemiología , TemperaturaRESUMEN
Impacts of energy retrofits on indoor thermal environment, i.e. temperature (T) and relative humidity (RH), as well as ventilation rates and carbon dioxide (CO2) concentrations, were assessed in 46 Finnish and 20 Lithuanian multi-family buildings, including 39 retrofitted case buildings in Finland and 15 in Lithuania (the remaining buildings were control buildings with no retrofits). In the Finnish buildings, high indoor T along with low RH levels was commonly observed both before and after the retrofits. Ventilation rates (l/s per person) were higher after the retrofits in buildings with mechanical exhaust ventilation than the corresponding values before the retrofits. Measured CO2 levels were low in vast majority of buildings. In Lithuania, average indoor T levels were low before the retrofits and there was a significant increase in the average T after the retrofits. In addition, average ventilation rate was lower and CO2 levels were higher after the retrofits in the case buildings (N=15), both in apartments with natural and mixed ventilation. Based on the results, assessment of thermal conditions and ventilation rates after energy retrofits is crucial for optimal indoor environmental quality and energy use.
RESUMEN
Sixteen existing multi-family buildings (94 apartments) in Finland and 20 (96 apartments) in Lithuania were investigated prior to their renovation in order to develop and test out a common protocol for the indoor environmental quality (IEQ) assessment, and to assess the potential for improving IEQ along with energy efficiency. Baseline data on buildings, as well as data on temperature (T), relative humidity (RH), carbon dioxide (CO2), carbon monoxide (CO), particulate matter (PM), nitrogen dioxide (NO2), formaldehyde, volatile organic compounds (VOCs), radon, and microbial content in settled dust were collected from each apartment. In addition, questionnaire data regarding housing quality and health were collected from the occupants. The results indicated that most measured IEQ parameters were within recommended limits. However, different baselines in each country were observed especially for parameters related to thermal conditions and ventilation. Different baselines were also observed for the respondents' satisfaction with their residence and indoor air quality, as well as their behavior related to indoor environment. In this paper, we present some evidence for the potential in improving IEQ along with energy efficiency in the current building stock, followed by discussion of possible IEQ indicators and development of the assessment protocol.