Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Mikrochim Acta ; 190(10): 417, 2023 09 28.
Artículo en Inglés | MEDLINE | ID: mdl-37768390

RESUMEN

A highly purified and bioactive immunoglobulin G monoclonal antibody against receptor-binding domain of SARS-CoV-2 (RBD-IgG-MAb) has been accurately quantified by amino acid determination using isotope dilution liquid chromatography-mass spectrometry. Absolute quantification of RBD-IgG-MAb was achieved by averaging 4 amino acid certified reference materials, which allows the quantitative value (66.1 ± 5.8 µg/L) to be traced to SI unit (mol). Afterwards, the RBD-IgG-MAb was employed as control and calibration compound for the development of a point-of-care testing (POCT) system based on colloidal gold lateral flow immunoassay, which aimed to rapidly and accurately detect the level of protective RBD-IgG after vaccination. Under the detection parameters, a sigmoidal curve has been plotted between signal intensity and the logarithmic concentration for quantitative detection with the limit of detection of about 0.39 µg/mL. The relative standard deviations of intra-assay and inter-assay were lower than 2.3% and 14%, and the recoveries ranged from 87 to 100%, respectively. Fingertip blood samples from 37 volunteers after vaccination were analyzed by the POCT system; results showed that levels of RBD-IgG in 33 out of 37 samples ranged from 0.45 to 2.46 µg/mL with the average level of 0.91 µg/mL. The developed POCT system has been successfully established with the quantity-traceability RBD-IgG-MAb as control and calibration compound, and the scientific contribution of this work can be promoted to other areas.


Asunto(s)
COVID-19 , Inmunoglobulina G , Humanos , SARS-CoV-2 , COVID-19/diagnóstico , Pruebas en el Punto de Atención , Aminoácidos
2.
Int J Mol Sci ; 24(16)2023 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-37628743

RESUMEN

Immunochromatographic assay (ICA) plays an important role in in vitro diagnostics because of its simpleness, convenience, fastness, sensitivity, accuracy, and low cost. The employment of magnetic nanoparticles (MNPs), possessing both excellent optical properties and magnetic separation functions, can effectively promote the performances of ICA. In this study, an ICA based on MNPs (MNP-ICA) has been successfully developed for the sensitive detection of carcinoembryonic antigen (CEA). The magnetic probes were prepared by covalently conjugating carboxylated MNPs with the specific monoclonal antibody against CEA, which were not only employed to enrich and extract CEA from serum samples under an external magnetic field but also used as a signal output with its inherent optical property. Under the optimal parameters, the limit of detection (LOD) for qualitative detection with naked eyes was 1.0 ng/mL, and the quantitative detection could be realized with the help of a portable optical reader, indicating that the ratio of optical signal intensity correlated well with CEA concentration ranging from 1.0 ng/mL to 64.0 ng/mL (R2 = 0.9997). Additionally, method comparison demonstrated that the magnetic probes were beneficial for sensitivity improvement due to the matrix effect reduction after magnetic separation, and the MNP-ICA is eight times higher sensitive than ICA based on colloidal gold nanoparticles. The developed MNP-ICA will provide sensitive, convenient, and efficient technical support for biomarkers rapid screening in cancer diagnosis and prognosis.


Asunto(s)
Antígeno Carcinoembrionario , Nanopartículas de Magnetita , Oro , Anticuerpos Monoclonales , Inmunoensayo
3.
Int J Mol Sci ; 23(17)2022 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-36077387

RESUMEN

Carbohydrate antigen 199 (CA199) is a serum biomarker which has certain value and significance in the diagnosis, prognosis, treatment, and postoperative monitoring of cancer. In this study, a lateral flow immunoassay based on europium (III) polystyrene time-resolved fluorescence microspheres (TRFM-based LFIA), integrated with a portable fluorescence reader, has been successfully establish for rapid and quantitative analysis of CA199 in human serum. Briefly, time-resolved fluorescence microspheres (TRFMs) were conjugated with antibody I (Ab1) against CA199 as detection probes, and antibody II (Ab2) was coated as capture element, and a "TRFMs-Ab1-CA199-Ab2" sandwich format would form when CA199 was detected by the TRFM-based LFIA. Under the optimal parameters, the detection limit of the TRFM-based LFIA for visible quantitation with the help of an ultraviolet light was 4.125 U/mL, which was four times lower than that of LFIA based on gold nanoparticles. Additionally, the fluorescence ratio is well linearly correlated with the CA199 concentration (0.00-66.0 U/mL) and logarithmic concentration (66.0-264.0 U/mL) for quantitative detection. Serum samples from 10 healthy people and 10 liver cancer patients were tested to confirm the performances of the point-of-care application of the TRFM-based LFIA, 20.0 U/mL of CA199 in human serum was defined as the threshold for distinguishing healthy people from liver cancer patients with an accuracy of about 60%. The establishment of TRFM-based LFIA will provide a sensitive, convenient, and efficient technical support for rapid screening of CA199 in cancer diagnosis and prognosis.


Asunto(s)
Neoplasias Hepáticas , Nanopartículas del Metal , Biomarcadores de Tumor , Oro , Humanos , Inmunoensayo , Límite de Detección , Microesferas
4.
Talanta ; 258: 124462, 2023 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-36963149

RESUMEN

More than forty antigen testing kits have been approved to response the prevalence of SARS-CoV-2 and its variant strains. However, the approved antigen testing kits are not capable of quantitative detection. Here, we successfully developed a lateral flow immunoassay based on colloidal gold nanoparticles (CGNP-based LFIA) for nucleocapsid (N) protein of SARS-CoV-2 quantitative detection. Delta strain (NMDC60042793) of SARS-CoV-2 have been cultured and analyzed by our developed digital PCR and LFIA methods to explore the relationship between N protein amount and N gene level. It indicated that the linear relationship (y = 47 ×) between N protein molecule number and N gene copy number exhibited very well (R2 = 0.995), the virus titers and N protein amount can be roughly estimated according to nucleic acid testing. Additionally, detection limits (LODs) of nine approved antigen testing kits also have been evaluated according to the Guidelines for the registration review of 2019-nCoV antigen testing reagents. Only three antigen testing kits had LODs as stated in the instructions, the LODs of Kits have been converted into the N gene and N protein levels, according to the established relationships among virus titer vers. N gene and antigen. Results demonstrated that the sensitivity of nucleic acid testing is at least 1835 times higher than that of antigen testing. We expect that the relationship investigation and testing kits evaluation have the important directive significance to precise epidemic prevention.


Asunto(s)
COVID-19 , Nanopartículas del Metal , Ácidos Nucleicos , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Oro , Proteínas de la Nucleocápside/genética , Sensibilidad y Especificidad
5.
Biosensors (Basel) ; 12(2)2022 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-35200362

RESUMEN

Neutralizing antibody (NAb) is a family of antibodies with special functions, which afford a degree of protection against infection and/or reduce the risk of clinically severe infection. Receptor binding domain (RBD) in the spike protein of SARS-CoV-2, a portion of the S1 subunit, can stimulate the immune system to produce NAb after infection and vaccination. The detection of NAb against SARS-CoV-2 is a simple and direct approach for evaluating a vaccine's effectiveness. In this study, a direct, rapid, and point-of-care bicolor lateral flow immunoassay (LFIA) was developed for NAb against SARS-CoV-2 detection without sample pretreatment, and which was based on the principle of NAb-mediated blockage of the interaction between RBD and angiotensin-converting enzyme 2. In the bicolor LFIA, red and blue latex microspheres (LMs) were used to locate the test and control lines, leading to avoidance of erroneous interpretations of one-colored line results. Under the optimal conditions, NAb against SARS-CoV-2 detection carried out using the bicolor LFIA could be completed within 9 min, and the visible limit of detection was about 48 ng/mL. Thirteen serum samples were analyzed, and the results showed that the NAb levels in three positive serum samples were equal to, or higher than, 736 ng/mL. The LM-based bicolor LFIA allows one-step, rapid, convenient, inexpensive, and user-friendly determination of NAb against SARS-CoV-2 in serum.


Asunto(s)
Anticuerpos Neutralizantes , Anticuerpos Antivirales , COVID-19 , Anticuerpos Neutralizantes/aislamiento & purificación , Anticuerpos Antivirales/aislamiento & purificación , COVID-19/diagnóstico , Cromatografía de Afinidad , Humanos , Látex , Microesferas , SARS-CoV-2 , Glicoproteína de la Espiga del Coronavirus/inmunología
6.
Biosensors (Basel) ; 12(1)2021 Dec 29.
Artículo en Inglés | MEDLINE | ID: mdl-35049641

RESUMEN

The coronavirus disease 2019 (COVID-19) pandemic caused by severe acute respiratory coronavirus 2 (SARS-CoV-2) is still raging all over the world. Hence, the rapid and sensitive screening of the suspected population is in high demand. The nucleocapsid protein (NP) of SARS-CoV-2 has been selected as an ideal marker for viral antigen detection. This study describes a lateral flow immunoassay (LFIA) based on colloidal gold nanoparticles for rapid NP antigen detection, in which sensitivity was improved through copper deposition-induced signal amplification. The detection sensitivity of the developed LFIA for NP antigen detection (using certified reference materials) under the optimized parameters was 0.01 µg/mL and was promoted by three orders of magnitude to 10 pg/mL after copper deposition signal amplification. The LFIA coupled with the copper enhancement technique has many merits such as low cost, high efficiency, and high sensitivity. It provides an effective approach to the rapid screening, diagnosis, and monitoring of the suspected population in the COVID-19 outbreak.


Asunto(s)
COVID-19 , Cobre , Proteínas de la Nucleocápside de Coronavirus/aislamiento & purificación , Inmunoensayo , Nanopartículas del Metal , Anticuerpos Antivirales , Oro , Humanos , Fosfoproteínas , SARS-CoV-2 , Sensibilidad y Especificidad
7.
Magn Reson Imaging ; 26(3): 401-12, 2008 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-18082991

RESUMEN

The method Hankel Total Least Squares (HTLS)-PK, which successfully incorporates prior knowledge of known signal poles into the method HTLS, has been proven to greatly improve the performance for parameter estimation of overlapping peaks of magnetic resonance spectroscopy (MRS) signal. In addition, decimation is also proposed as a way to increase the performance of subspace-based parameter estimation methods in the case of oversampling. Taking advantage of decimation in combination with prior knowledge to estimate the MRS signal parameters, two novel subspace-based parameter estimation methods, HTLSDSumPK and HTLSDStackPK, are presented in this paper. The experimental results and relevant analysis show that the methods HTLSDSumPK, HTLSDStackPK and HTLS-PK are slightly better than the method HTLS at low noise levels; however, the three prior-knowledge-incorporating methods, especially the method HTLSDSumPK, have much better performance than the method HTLS at high noise levels in the terms of robustness, estimated accuracy and computational complexity. Even if some inaccuracy of prior knowledge is considered, the method HTLSDSumPK also shows some advantages.


Asunto(s)
Espectroscopía de Resonancia Magnética/métodos , Animales , Química Encefálica , Simulación por Computador , Humanos , Análisis de los Mínimos Cuadrados , Hígado/irrigación sanguínea , Ratas , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA