Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 53
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Pacing Clin Electrophysiol ; 41(1): 22-27, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29211301

RESUMEN

BACKGROUND: Pulmonary vein isolation (PVI) has become a widely accepted therapy in patients suffering from symptomatic atrial fibrillation (AF). HYPOTHESIS: AF-free survival differs in patients with left common pulmonary vein (LCPV) after PVI with second-generation cryoballoon. METHODS: We included patients scheduled for first PVI for paroxysmal or persistent AF. Symptomatic and/or documented arrhythmia episodes (>30 seconds) were defined as AF recurrence, excluding a 3-month blanking period. RESULTS: We observed a LCPV in 37 of 270 consecutive patients (13.7%). Analyses were performed in a 1:1 propensity score matched cohort of 68 patients. During a median follow-up of 77.0 weeks, 37 patients (54.4%) had recurrent AF. The prevalence of LCPV was numerically higher in patients with AF recurrence (62.2% vs 35.5%, P  =  0.051) and Kaplan-Meier analysis showed lower AF-free survival in patients with existence of a LCPV (P  =  0.028). At 1-year follow-up, 70.6% of patients without versus 55.1% of patients with LCPV were free of AF. Multivariate Cox regression analysis revealed presence of a LCPV (hazard ratio [HR]: 2.996), chronic heart failure (HR: 3.423), and mitral regurgitation > I° (HR: 2.571) as predictors of AF recurrence. CONCLUSION: Patients with LCPV had significantly reduced AF-free survival after ablation with the second-generation cryoballoon, despite similar acutely successful PVIs.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía/instrumentación , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/diagnóstico por imagen , Angiografía Coronaria , Ecocardiografía , Femenino , Fluoroscopía , Alemania , Humanos , Masculino , Puntaje de Propensión , Recurrencia , Estudios Retrospectivos , Resultado del Tratamiento
2.
Europace ; 17(7): 1030-7, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25662987

RESUMEN

AIMS: The purpose of the FAST-PVI study was to compare 'traditional' ablation tools based on 'point-by-point' technology with the new 'anatomically designed' technologies in terms of procedure times and related costs for the treatment of paroxysmal atrial fibrillation. METHODS AND RESULTS: Four hundred and fifty-two consecutive ablation procedures (222 'anatomically designed', 136 Arctic Front® and 86 PVAC®) and 230 'point-by-point' ablations (100 CARTO XP and 130 NavX navigation systems) performed by nine university centres across Germany from 2006 to 2010 were evaluated retrospectively. Staffing and resources times for each procedure were documented together with patient morbidities, complications, and pulmonary veins isolations. On the basis of DRG data from 2006 to 2010, human resources use and equipment maintenance costs were assigned to ablation procedure and calendar year. All procedural times were significantly higher in 'point-by-point' technologies compared with 'anatomically designed' ablations [average lab occupancy time 185.30 vs. 280.28 min; physician time 152.21 vs. 238.04 min; support time 183.43 vs. 278.34 min and fluoroscopy time 29.11 vs. 40.72 min; P < 0.001 (95% confidence interval, CI)]. For each ablation procedure human resource use per operating minute resulted in lower costs for 'anatomically designed' ablations [€744.24 per patient; P < 0.001 (95% CI)]. Savings due to reduced duration in 'anatomically designed' technologies accrued to 20% lower human resource costs. Sensitivity analyses did not lead to any significant variations on the outcomes parameter cost per minute. CONCLUSION: FAST-PVI showed reductions in ablation procedural time may lead to increased hospital capacity and non-device-related cost-savings, while maintaining quality.


Asunto(s)
Fibrilación Atrial/economía , Fibrilación Atrial/cirugía , Ablación por Catéter/economía , Costos de la Atención en Salud/estadística & datos numéricos , Hospitalización/economía , Tempo Operativo , Fibrilación Atrial/epidemiología , Ablación por Catéter/clasificación , Ablación por Catéter/instrumentación , Análisis Costo-Beneficio , Femenino , Alemania/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Estudios Retrospectivos , Resultado del Tratamiento
3.
J Cardiovasc Electrophysiol ; 25(8): 859-865, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24724724

RESUMEN

INTRODUCTION: Right phrenic nerve palsy (PNP) is a typical complication of cryoballoon ablation of the right-sided pulmonary veins (PVs). Phrenic nerve function can be monitored by palpating the abdomen during phrenic nerve pacing from the superior vena cava (SVC pacing) or by fluoroscopy of spontaneous breathing. We sought to compare the sensitivity of these 2 techniques during cryoballoon ablation for detection of PNP. METHODS AND RESULTS: A total of 133 patients undergoing cryoballoon ablation were monitored with both SVC pacing and fluoroscopy of spontaneous breathing during ablation of the right superior PV. PNP occurred in 27/133 patients (20.0%). Most patients (89%) had spontaneous recovery of phrenic nerve function at the end of the procedure or on the following day. Three patients were discharged with persistent PNP. All PNP were detected first by fluoroscopic observation of diaphragm movement during spontaneous breathing, while diaphragm could still be stimulated by SVC pacing. In patients with no recovery until discharge, PNP occurred at a significantly earlier time (86 ± 34 seconds vs. 296 ± 159 seconds, P < 0.001). No recovery occurred in 2/4 patients who were ablated with a 23 mm cryoballoon as opposed to 1/23 patients with a 28 mm cryoballoon (P = 0.049). CONCLUSION: Fluoroscopic assessment of diaphragm movement during spontaneous breathing is more sensitive for detection PNP as compared to SVC pacing. PNP as assessed by fluoroscopy is frequent (20.0%) and carries a high rate of recovery (89%) until discharge. Early onset of PNP and use of 23 mm cryoballoon are associated with PNP persisting beyond hospital discharge.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía/efectos adversos , Diafragma/inervación , Monitoreo Intraoperatorio/métodos , Parálisis/diagnóstico , Traumatismos de los Nervios Periféricos/diagnóstico , Nervio Frénico/lesiones , Venas Pulmonares/cirugía , Respiración , Adulto , Anciano , Puntos Anatómicos de Referencia , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Estimulación Eléctrica , Femenino , Fluoroscopía , Humanos , Tiempo de Internación , Masculino , Persona de Mediana Edad , Palpación , Parálisis/diagnóstico por imagen , Parálisis/etiología , Parálisis/fisiopatología , Alta del Paciente , Traumatismos de los Nervios Periféricos/diagnóstico por imagen , Traumatismos de los Nervios Periféricos/etiología , Traumatismos de los Nervios Periféricos/fisiopatología , Nervio Frénico/fisiopatología , Nervio Frénico/cirugía , Valor Predictivo de las Pruebas , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/fisiopatología , Recuperación de la Función , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
4.
J Mol Cell Cardiol ; 65: 19-32, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24060583

RESUMEN

Atrial fibrillation (AF) is the most common type of cardiac arrhythmia and a major cause of stroke. In the mammalian heart the gap junction proteins connexin40 (Cx40) and connexin43 (Cx43) are strongly expressed in the atrial myocardium mediating effective propagation of electrical impulses. Different heterozygous mutations in the coding region for Cx40 were identified in patients with AF. We have generated transgenic Cx40A96S mice harboring one of these mutations, the loss-of-function Cx40A96S mutation, as a model for atrial fibrillation. Cx40A96S mice were characterized by immunochemical and electrophysiological analyses. Significantly reduced atrial conduction velocities and strongly prolonged episodes of atrial fibrillation were found after induction in Cx40A96S mice. Analyses of the gating properties of Cx40A96S channels in cultured HeLa cells also revealed significantly lower junctional conductance and enhanced sensitivity voltage gating of Cx40A96S in comparison to Cx40 wild-type gap junctions. This is caused by reduced open probabilities of Cx40A96S gap junction channels, while single channel conductance remained the same. Similar to the corresponding patient, heterozygous Cx40A96S mice revealed normal expression levels and localization of the Cx40 protein. We conclude that heterozygous Cx40A96S mice exhibit prolonged episodes of induced atrial fibrillation and severely reduced atrial conduction velocities similar to the corresponding human patient.


Asunto(s)
Fibrilación Atrial/genética , Fibrilación Atrial/fisiopatología , Conexinas/genética , Sistema de Conducción Cardíaco/fisiopatología , Mutación/genética , Animales , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/metabolismo , Conexina 43/metabolismo , Conexinas/metabolismo , Electrocardiografía , Fibrosis Endomiocárdica/metabolismo , Fibrosis Endomiocárdica/patología , Fibrosis Endomiocárdica/fisiopatología , Mapeo Epicárdico , Uniones Comunicantes/genética , Células HeLa , Atrios Cardíacos/metabolismo , Atrios Cardíacos/patología , Atrios Cardíacos/fisiopatología , Humanos , Activación del Canal Iónico , Ratones , Ratones Transgénicos , Transporte de Proteínas , Factores de Tiempo , Transfección , Ultrasonografía , Proteína alfa-5 de Unión Comunicante
5.
Pacing Clin Electrophysiol ; 36(2): 194-202, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23379836

RESUMEN

PURPOSE: Cavotricuspid isthmus-dependent atrial flutter (AFL) can occur in a paroxysmal or persistent pattern. The aim of this study was to identify clinical, echocardiographic, and electrophysiological risk factors independently associated with persistence of AFL. METHODS: Patients of the recently published AURUM 8 study with paroxysmal versus persistent AFL were compared with respect to clinical and echocardiographic baseline characteristics as well as procedural parameters. The AURUM 8 study is a randomized, multicenter clinical trial comparing the efficacy and safety of gold versus platinum-iridium 8-mm-tip ablation. AFL was paroxysmal in 218 patients and persistent in 210 patients. RESULTS: Univariate analysis revealed that patients with persistent AFL had higher New York Heart Association class (P = 0.002), shorter time since 1st AFL episode (median 0.18 vs 0.34, P = 0.037), a higher prevalence of previous coronary artery bypass grafting surgery (17% vs 9%, P = 0.02), left ventricular hypertrophy (17% vs 8%, P = 0.005), dyspnea during AFL (P < 0.001), mitral regurgitation (P = 0.002), tricuspid regurgitation (P = 0.049), and pulmonary hypertension (P = 0.01). Palpitations during AFL were less frequent in patients with persistent AFL (P = 0.001). Multivariate analysis revealed that age, weight, AFL diagnosis after initiation of class IC or III antiarrhythmic drugs for atrial fibrillation, history of left ventricular hypertrophy, dyspnea during AFL and mitral regurgitation on echocardiography were significant independent variables associated with persistent AFL. A history of atrial fibrillation and palpitations during AFL were independently associated with paroxysmal AFL. CONCLUSIONS: We were able to identify clinical and echocardiographic risk factors associated with persistence of typical AFL. Treatment of these risk factors can potentially not only prevent the transition from paroxysmal to persistent AFL, but maybe also the development or initiation of AFL in general.


Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/epidemiología , Aleteo Atrial/diagnóstico , Aleteo Atrial/epidemiología , Ecocardiografía/estadística & datos numéricos , Anciano , Fibrilación Atrial/prevención & control , Aleteo Atrial/prevención & control , Enfermedad Crónica , Comorbilidad , República Checa/epidemiología , Femenino , Alemania/epidemiología , Humanos , Incidencia , Masculino , Reproducibilidad de los Resultados , Medición de Riesgo , Sensibilidad y Especificidad
6.
Basic Res Cardiol ; 107(6): 299, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22976005

RESUMEN

Survivin (Surv) belongs to the inhibitor of apoptosis protein family. Its cardiac-specific deletion results in reduced cardiomyocyte number, increased cardiomyocyte size and ploidy, and development of heart failure. Its impact on cardiac electrophysiology is unknown. In vivo transvenous electrophysiological studies were carried out in adult male mice with a cardiac-specific deletion of survivin (Surv(-/-); n = 12) and wild-type controls (Surv(+/+); n = 12). Epicardial activation mapping (EAM) was performed in Langendorff-perfused hearts of 16 Surv(-/-) and 6 Surv(+/+) mice. Surface-ECG showed lower heart rates in Surv(-/-) mice (326 ± 66 bpm vs. 440.6 ± 39 ms; P = 0.0001), accompanied by significantly prolonged P waves (20.3 ± 5.8 vs. 14.6 ± 2.0 ms; P = 0.009), PQ-(47.4 ± 8.6 vs. 41.1 ± 3.7 ms; P = 0.043), QRS- (19.5 ± 4.8 vs. 14.0 ± 1.0 ms; P = 0.002) and QT-intervals (41.6 ± 4.4 vs. 36.2 ± 3.4 ms; P = 0.003). The HV-interval was prolonged in Surv(-/-) mice (12.1 ± 2.4 vs. 9.3 ± 1.4 ms; P = 0.0045). We found impaired sinus-nodal function (sinus node recovery times: 310.2 ± 76.6 vs. 207.8 ± 68.6 ms; P = 0.003) and AV-nodal conduction (Wenckebach-periodicity: 105.9 ± 15.9 vs. 79.6 ± 8.1 ms; P = 0.0002). EAM showed significant slowing and heterogeneity of conduction in the myocardium of Surv(-/-) mice. All Surv(-/-) mice showed spontaneous supraventricular and ventricular ectopic beats (P < 0.0001 vs. wildtype). Quantitative immunofluorescence staining for connexin43 (Cx43) revealed a decrease in both per cardiomyocyte and single gap junction. Surv(-/-) mice exhibit severe global conduction attenuations in atrial and ventricular myocardium as well as the specific conduction system, accompanied by lower connexin43 levels. Lack of susceptibility to AF and VT suggests that reduced cardiomyocyte number and increased size constitute determinants of electrical stableness in the heart and counteract potentially proarrhythmogenic connexin43 loss in Surv(-/-).


Asunto(s)
Arritmias Cardíacas/metabolismo , Conexina 43/metabolismo , Proteínas Inhibidoras de la Apoptosis/metabolismo , Miocitos Cardíacos/metabolismo , Proteínas Represoras/metabolismo , Complejos Prematuros Ventriculares/etiología , Animales , Biometría , Síndrome de Brugada , Trastorno del Sistema de Conducción Cardíaco , Electrocardiografía , Mapeo Epicárdico , Uniones Comunicantes/metabolismo , Sistema de Conducción Cardíaco/anomalías , Sistema de Conducción Cardíaco/metabolismo , Técnicas In Vitro , Masculino , Ratones , Cadenas Pesadas de Miosina/metabolismo , Periodo Refractario Electrofisiológico , Survivin
7.
J Cardiovasc Electrophysiol ; 23(11): 1254-7, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22486804

RESUMEN

The risk of atrioesophageal fistula after cryoballoon pulmonary vein isolation is thought to be much lower than after radiofrequency ablation, seeing that no data exist on this complication so far. We report for the first time on the occurrence of an atrioesophageal fistula 4 weeks after cryoballoon ablation at the site of the left inferior pulmonary vein. We suggest that even when using cryothermal ablation technique, an imaging modality to assess the proximity of esophagus and left atrium should be routinely performed to avoid this fatal complication.


Asunto(s)
Fibrilación Atrial/cirugía , Catéteres Cardíacos , Criocirugía/efectos adversos , Criocirugía/instrumentación , Fístula Esofágica/etiología , Fístula/etiología , Cardiopatías/etiología , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/diagnóstico , Técnicas Electrofisiológicas Cardíacas , Embolia Aérea/etiología , Fístula Esofágica/diagnóstico por imagen , Fístula Esofágica/cirugía , Fístula/diagnóstico por imagen , Fístula/cirugía , Atrios Cardíacos/diagnóstico por imagen , Cardiopatías/diagnóstico por imagen , Cardiopatías/cirugía , Humanos , Masculino , Estado Vegetativo Persistente/etiología , Venas Pulmonares/diagnóstico por imagen , Reoperación , Accidente Cerebrovascular/etiología , Factores de Tiempo , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
8.
J Cardiovasc Electrophysiol ; 23(3): 247-55, 2012 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21955059

RESUMEN

OBJECTIVE: Since predictors of recurrence of atrial fibrillation (AF) after ablation procedures are poorly defined, this prospective study was conducted to assess the value of left atrial (LA) deformation imaging with two-dimensional speckle-tracking (2D-ST) to predict AF recurrences after successful ablation procedures. METHODS AND RESULTS: One hundred and three consecutive patients (age 58.1 ± 16.6 years, 72.8% male) with AF (76 paroxysmal, 27 persistent) and 30 matched controls underwent transthoracic echocardiography and 2D-ST-LA-deformation analysis with assessment of LA-radial and LA-longitudinal strain (Sr, Sl), and velocities derived from the apical 4- and 2-chamber views (4CV, 2CV). AF recurrence was assessed during 6 months of follow-up. For determination of AF-related LA changes, AF patients were compared to controls and patients with AF recurrences after ablation procedures (n = 30, 29.1%) were compared with patients who maintained sinus rhythm (n = 73, 70.9%). Atrial deformation capabilities were significantly reduced (P < 0.0005) in patients with AF (4CVSl 17.8 ± 13.5%; 4CVSr 22.3 ± 14.9%; 4CV-velocities 2.53 ± 0.97 seconds) when compared with controls (4CVSl 31.3 ± 12.4%; 4CVSr 30.3 ± 9.1%; 4CV-velocities 3.48 ± 1.01 cm/s). Independent predictors for AF recurrence after ablation procedures were 2CV-LA-global-strain (Sr, P = 0.03; Sl, P = 0.003), 4CV-LA-gobal-strain (Sr, P = 0.03; Sl, P = 0.02), and regional LA-septal wall-Sl (P = 0.008). LA-global-strain parameters were superior to regional LA function analysis for the prediction of AF recurrences, with cutoff values (cov), hazard ratios (HR), positive and negative predictive values (PPV, NPV) were: 4CVSl cov, 10.79% (HR 27.8, P < 0.0005; PPV 78.8%, NPV 93.9%), 4CVSr cov, -16.65% (HR 24.8, P < 0.0005; PPV 69.4%, NPV 96.6%), 2CVSl cov, 12.31% (HR 22.7, P < 0.0005; PPV 75.8%, NPV 95.3%), and 2CVSr cov, -14.9% (HR 12.9, P < 0.0005; PPV 64.3%, NPV 93.2%). CONCLUSION: Compared with controls, AF itself seems to decrease LA deformation capabilities. The assessment of global LA strain with 2D-ST identifies patients with high risk for AF recurrence after ablation procedures. This imaging technique may help to improve therapeutic guiding for patients with AF.


Asunto(s)
Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Ablación por Catéter , Ecocardiografía/métodos , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Anciano , Función del Atrio Izquierdo , Estudios de Cohortes , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Curva ROC , Recurrencia , Reproducibilidad de los Resultados
9.
J Cardiovasc Electrophysiol ; 23(7): 717-21, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22429859

RESUMEN

INTRODUCTION: In order to optimize power delivery into the myocardium during radiofrequency ablation (RFA) without overheating the electrode tip, active cooling of the tip electrode as well as electrode tips made of gold have evolved. Recently, an externally irrigated gold tip electrode ablation catheter has been developed to combine the advantages of these 2 technologies. We sought to investigate the procedural parameters tip temperature, delivered power and cooling flow requirements of the irrigated gold tip catheter in comparison to the conventional irrigated platinum iridium (Pt) tip catheter in pulmonary vein isolation (PVI) and cavotricuspid isthmus (CTI) ablation. METHODS AND RESULTS: Sixty patients referred for first PVI were randomized into ablation with irrigated gold tip catheter versus irrigated Pt tip catheter. Forty-nine patients received ablation of CTI following PVI. Mean and standard deviation from all measurements were calculated for each patient. During RFA of pulmonary veins, mean catheter tip temperature was significantly lower in the gold group (35.4 ± 0.9 °C vs 38.2 ± 0.8 °C, P < 0.001), and total amount of delivered energy was higher (1303.1 ± 81.1 W vs 1223.7 ± 115.6 W, P = 0.004). During CTI ablation, necessary saline flow was almost 2.5-fold lower in the gold group (22.5 ± 5.9 mL/min vs 52.5 ± 9.7 mL/min, P < 0.001), accompanied by significantly lower tip temperature (39.1 ± 0.6 °C vs 40.5 ± 1.4 °C, P < 0.001). CONCLUSION: The irrigated gold tip electrode allows to deliver significantly more energy at a lower electrode tip temperature in RFA of PV and CTI in comparison to the irrigated Pt tip electrode. The required saline flow during CTI ablation is much lower than in Pt.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/instrumentación , Catéteres , Oro , Calor , Platino (Metal) , Venas Pulmonares/cirugía , Irrigación Terapéutica/instrumentación , Válvula Tricúspide/cirugía , Vena Cava Inferior/cirugía , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Diseño de Equipo , Femenino , Alemania , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Venas Pulmonares/fisiopatología , Resultado del Tratamiento , Válvula Tricúspide/fisiopatología , Vena Cava Inferior/fisiopatología
10.
J Cardiovasc Electrophysiol ; 23(5): 479-85, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22458432

RESUMEN

INTRODUCTION: The recently proposed "maximum voltage-guided" (MVG) technique for radiofrequency catheter ablation of atrial flutter targets high-voltage electrograms along cavotricuspid isthmus (CTI) to ablate the functionally important anatomic muscle bundles alone, without drawing a complete anatomic line across the CTI. This innovative approach may shorten ablation time and procedure duration. METHODS AND RESULTS: Within the multicenter AURUM 8 study, which compared 8-mm gold- and Pt-Ir-tip catheters in atrial flutter ablation, we made a post hoc comparison of procedural data from 72 patients treated with MVG technique with data from 281 patients undergoing anatomic CTI ablation (unmatched) and with data from 72 patients selected from among those 281 patients such that they were matched with the MVG group with respect to selected baseline parameters and catheter type (matched). The MVG technique markedly reduced (P < 0.001) ablation time (mean 6.9 minutes vs 10.9/9.7 minutes [unmatched/matched]), number of lesions (8.3 vs 13.7/12.9), fluoroscopy time (9.5 minutes vs 20.6/17.9 minutes), procedure duration (59 minutes vs 93/86 minutes), and energy delivered (19 kJ vs 34/30 kJ) compared with anatomic CTI ablation. The incidence of charring was higher for MVG than for anatomic ablation technique (31.9% vs 18.5/15.3%, P < 0.05), where Pt-Ir tip catheters were 6-fold more susceptible to charring than gold-tip catheters (P < 0.001), likely because of a lower thermal conductivity of the Pt-Ir material. The acute success rate was slightly better for MVG than for anatomic ablation technique (97.2% vs 92.2/91.7%, P = n.s.). CONCLUSION: Major procedural parameters are remarkably improved with MVG technique. Gold-tip catheters are substantially less susceptible to charring and may therefore be preferred over Pt-Ir-tip catheters for MVG ablation technique.


Asunto(s)
Aleteo Atrial/cirugía , Ablación por Catéter/métodos , Adulto , Anciano , Aleteo Atrial/diagnóstico , Aleteo Atrial/fisiopatología , Ablación por Catéter/efectos adversos , Ablación por Catéter/instrumentación , Catéteres , Distribución de Chi-Cuadrado , Técnicas Electrofisiológicas Cardíacas , Diseño de Equipo , Femenino , Alemania , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/prevención & control , Valor Predictivo de las Pruebas , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
11.
Pacing Clin Electrophysiol ; 35(11): e334-6, 2012 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-22845556

RESUMEN

Transcatheter ablation of the pulmonary veins (PVs) has been established as a therapeutic option for patients with symptomatic atrial fibrillation. Cryothermal energy is an alternative energy source that has been developed to overcome some of the disadvantages of radiofrequency ablation. The major complication of the cryoballoon technique seems to be right-sided phrenic nerve injury (PNI) following ablation of the right superior PV. This case report describes a left-sided PNI after cryoballoon ablation of the left superior PV.


Asunto(s)
Angioplastia de Balón/efectos adversos , Fibrilación Atrial/cirugía , Criocirugía/efectos adversos , Sistema de Conducción Cardíaco/cirugía , Traumatismos de los Nervios Periféricos/etiología , Nervio Frénico/lesiones , Venas Pulmonares/cirugía , Anciano , Fibrilación Atrial/complicaciones , Humanos , Masculino , Traumatismos de los Nervios Periféricos/diagnóstico , Resultado del Tratamiento
12.
Europace ; 13(1): 102-8, 2011 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-20876601

RESUMEN

AIMS: Gold electrodes have the theoretical advantage of creating bigger lesions than platinum-iridium (Pt-Ir) electrodes. We performed a prospective randomized study to compare the clinical efficacy of standard 8 mm Pt-Ir tip catheter (control) and 8 mm gold-tip catheters in the ablation of the cavotricuspid isthmus (CTI)-dependent atrial flutter. METHODS AND RESULTS: A total of 463 patients undergoing CTI ablation in 19 clinical centres were randomized to receive the treatment by gold-tip or control catheter. The primary endpoint was cumulative radiofrequency (RF) application duration until achieving bidirectional CTI block. It did not differ significantly for the two catheters. The gold-tip catheter was, however, associated with a higher ablation success rate (94.3 vs. 89.0%, P = 0.042) and a substantially lower incidence of char and coagulum formation (4.8 vs. 37.9%, P < 0.001), which required exchange of 1 gold-tip (0.4%) and 10 control catheters (4.6%, P = 0.005). The gold-tip catheter delivered more mean power (52 ± 12 W) than the control catheter (48 ± 13 W, P < 0.001). Both mean and maximum temperatures measured by the thermocouple integrated in the catheter tip were statistically significantly lower in the gold (mean: 53.2 ± 4.7°C, max: 68.7 ± 6.6°C) than in the control catheter (54.3 ± 5.2 and 70.2 ± 7.0°C, respectively, P < 0.05). Fluoroscopy time, procedure duration, procedural-related complications, and arrhythmia recurrence during 6 months of follow-up did not differ between the two catheters. CONCLUSION: Owing to a higher primary ablation success rate and reduced incidence of char/coagulum formation, gold may be preferred over Pt-Ir as electrode material for 8 mm tip catheters for CTI ablation. ClinicalTrials.gov: NCT00326001 (http://clinicaltrials.gov/ct2/show/NCT00326001).


Asunto(s)
Aleteo Atrial/cirugía , Ablación por Catéter/instrumentación , Oro , Iridio , Platino (Metal) , Anciano , Ablación por Catéter/métodos , Electrodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Recurrencia , Estudios Retrospectivos , Conductividad Térmica , Resultado del Tratamiento
13.
Pacing Clin Electrophysiol ; 34(7): 894-9, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21418240

RESUMEN

BACKGROUND: This study investigated the overall mortality and the incidence of ventricular tachyarrhythmia (VT) in 99 patients with nonischemic cardiomyopathy (NICM) and with an implantable cardioverter defibrillator (ICD) suffering from heart failure. METHODS: We performed a stepwise regression model to identify independent risk factors for the occurrence of ventricular arrhythmias. Using a Cox regression model, independent risk factors for total mortality were evaluated and, subsequently, a Kaplan-Meier analysis was applied. The primary endpoint of this study was the identification of independent predictors of overall mortality and the incidence of malignant arrhythmias. RESULTS: One hundred twenty-five VT (≥310 ms), 51 fast VT (between 310 ms and 240 ms), and 48 episodes of ventricular fibrillation (≤240 ms) were documented in 32 patients. Independent predictors of arrhythmias detected and treated by the ICD included female gender (odds ratio [OR] 3.4), lack of statin therapy (OR 3.5), and increased serum creatinine (OR 3.7). The Kaplan-Meier analysis showed no difference in survival between participants with or without VT. Total mortality was predicted by increased age (OR 2.3) and an impaired renal function (OR 1.9), independently. CONCLUSIONS: In this cohort of NICM patients with heart failure, female gender, lack of statin therapy, and increased creatinine represented independent risk factors for the incidence of malignant arrhythmias. Furthermore, renal insufficiency and age favored total mortality. Considering these results, impaired renal function might represent a valuable noninvasive tool to identify NICM patients who, despite ICD implantation, have the highest risk of mortality and therefore require a particularly thorough follow-up.


Asunto(s)
Cardiomiopatías/complicaciones , Cardiomiopatías/mortalidad , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/mortalidad , Riñón/fisiopatología , Taquicardia Ventricular/etiología , Taquicardia Ventricular/mortalidad , Anciano , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Factores de Riesgo , Taquicardia Ventricular/epidemiología
14.
Pacing Clin Electrophysiol ; 34(6): 684-9, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21303390

RESUMEN

BACKGROUND: Little is known about the prevalence of upper extremity vein obstruction or anomalies in patients before first implantation of implantable cardioverter defibrillator (ICD). It remains unclear in which patients contrast venography is warranted before implantation procedure. METHODS: Results of clinical data and contrast venography of 302 consecutive patients scheduled for first ICD implantation were analyzed. RESULTS: Prevalence of upper vein obstruction was 6.6% (20/302 patients) in a typical patient population undergoing first ICD implantation. Age, left ventricular ejection fraction, underlying heart disease, prior open-heart surgery, or cardiopulmonary resuscitation were not predictors of obstruction. Patients with previous cardiac pacemaker implantation had a higher rate of obstruction, though this was not statistically significant (20% vs 15.7%, P = 0.54). Persistent left vena cava was found in 0.7%. CONCLUSION: There is no clinical parameter sufficient enough to predict upper extremity venous obstruction. Contrast venography may be considered in patients with previous pacemaker placement but should not be a routine diagnostic tool in unselected patients prior to first ICD-implantation procedure.


Asunto(s)
Desfibriladores Implantables/estadística & datos numéricos , Falla de Prótesis , Implantación de Prótesis/estadística & datos numéricos , Extremidad Superior/irrigación sanguínea , Insuficiencia Venosa/epidemiología , Femenino , Alemania/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Medición de Riesgo , Factores de Riesgo
15.
Europace ; 12(10): 1439-45, 2010 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-20817721

RESUMEN

AIMS: Malignant ventricular arrhythmias and inappropriate therapies represent unsolved problems in patients with implantable cardioverter/defibrillator (ICD) for primary prevention. This study focuses on the incidence of such therapies and thereby seeks to identify new predictors of adverse events to enhance risk stratification. METHODS AND RESULTS: Ninety-four consecutive patients with mild-to-moderate heart failure (NYHA II-III) and depressed left ventricular function (≤35%) were followed for 34 ± 20 months. Two hundred and ninety-one malignant ventricular arrhythmias were documented in 51 patients (54%). Eighteen patients (19%) received inappropriate ICD therapies (e.g. atrial fibrillation, sinus tachycardia, etc.). Patients with malignant arrhythmia (1.34 ± 0.44 vs. 1.16 ± 0.4 mg/dL, P = 0.017) and patients suffering from inappropriate ICD therapies (1.54 ± 0.48 vs. 1.2 ± 0.38 mg/dL; P = 0.007) revealed a significantly worse renal function before ICD implantation than participants without any therapy. An increased serum creatinine at baseline (2 vs. 1 mg/dL; odds ratio (OR) 3.96; P = 0.02; 95% CI: 1.2-13.04) and NHYA class III compared with II (OR: 2.96; P = 0.02; 95% CI: 1.16-7.48) represent strong and independent predictors for the occurrence of ventricular arrhythmias. Moreover, an impaired renal function is identified as an independent risk factor for inappropriate therapies (OR: 5.6; P = 0.004; 95% CI: 1.72-18.22). CONCLUSION: An impaired renal function and advanced heart failure before ICD implantation for primary prevention are identified as independent predictors for the incidence of appropriate ICD interventions. With regard to current guidelines and economical aspects, patients suffering from an impaired renal function or advanced heart failure seem to benefit most from ICD therapy.


Asunto(s)
Arritmias Cardíacas/epidemiología , Desfibriladores Implantables , Insuficiencia Cardíaca/epidemiología , Insuficiencia Renal/epidemiología , Anciano , Arritmias Cardíacas/etiología , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/prevención & control , Estudios de Cohortes , Creatinina/sangre , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/fisiopatología , Humanos , Incidencia , Persona de Mediana Edad , Insuficiencia Renal/complicaciones , Insuficiencia Renal/fisiopatología , Estudios Retrospectivos , Factores de Riesgo , Disfunción Ventricular Izquierda/epidemiología , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/terapia
16.
Europace ; 12(1): 52-7, 2010 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-19933517

RESUMEN

AIMS: Left atrial catheter ablation of the pulmonary veins (PV) has evolved as an important therapeutic option for the treatment of atrial fibrillation (AF). We aimed to investigate the incidence and predictors of silent cerebral embolism associated with PV catheter ablation, detected by diffusion-weighted magnetic resonance imaging (DW-MRI). METHODS AND RESULTS: We performed a prospective analysis of 53 consecutive patients with persistent or paroxysmal AF that underwent PV ablation and post-procedural cerebral MRI 1 day after lasso catheter-guided ostial PV ablation. Patients were analysed for possible demographical, medical, echocardiographical, and procedural predictors of embolic events. A mean of 3.5 +/- 0.5 PVs were ablated per patient. In six patients, DW-MRI depicted new clinically silent microembolism after PV ablation (11%). The number of ineffective medical antiarrhythmic agents prior to ablation procedure was significantly higher in the embolism group (3.3 +/- 0.5 vs. 2.2 +/- 1.4, P = 0.014). Coronary heart disease (CAD) was more frequent in patients with cerebral embolisms (33 vs. 2%, P = 0.031); left ventricular volume (130 +/- 12 vs. 103 +/- 26 mL, P = 0.002), and septal wall thickness (13.0 +/- 1.4 vs. 7.9 +/- 4.8 mm, P = 0.025) were significantly increased. CONCLUSION: This study shows a high incidence of silent micro-embolic events after PV ablation. CAD, left ventricular dilatation, and hypertrophy were potential predictors of this complication.


Asunto(s)
Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Ablación por Catéter/estadística & datos numéricos , Embolia Intracraneal/epidemiología , Venas Pulmonares/cirugía , Comorbilidad , Femenino , Alemania/epidemiología , Humanos , Incidencia , Imagen por Resonancia Magnética/estadística & datos numéricos , Masculino , Persona de Mediana Edad , Medición de Riesgo/métodos , Factores de Riesgo
17.
J Cardiovasc Electrophysiol ; 20(12): 1343-8, 2009 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-19656254

RESUMEN

INTRODUCTION: Ablation of pulmonary veins (PV) is an established therapeutic option for patients with symptomatic drug-refractory paroxysmal atrial fibrillation (AF). Radiofrequency (RF) is currently the most widespread energy source for PV ablation. Cryothermal energy applied with a cryoballoon technique as an alternative has recently evolved. METHODS AND RESULTS: In a case-control setting, we compared 20 patients with paroxysmal AF who underwent their first PV ablation with the cryoballoon technique to 20 matched patients with conventional RF ablation. In the case of persistent electrical potentials after cryoballoon ablation, it was combined with ablation with a conventional cryocatheter. All patients performed daily event recording for 3 months after ablation procedure. Ablation parameters and success rate after 3 and 6 months were compared. In the cryoballoon group, the overall success rate was 55% (50% in the cryoballoon only group [14 patients] and 66% in the combination group [6 patients]), as opposed to the RF group with 45%. AF episode burden was lower after cryoballoon ablation. There was no significant difference between cryoballoon and RF ablation regarding procedure parameters. In the cryoballoon group, 3 phrenic nerve palsies occurred using the 23 mm balloon that resolved spontaneously. CONCLUSION: PV ablation with the cryoballoon technique is feasible and seems to have a similar success rate in comparison to RF ablation. Procedure- and fluoroscopy duration are not longer than in conventional RF ablation.


Asunto(s)
Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Cateterismo Cardíaco/métodos , Ablación por Catéter/métodos , Cateterismo/métodos , Criocirugía/instrumentación , Venas Pulmonares/cirugía , Adulto , Anciano , Estudios de Casos y Controles , Femenino , Sistema de Conducción Cardíaco/cirugía , Humanos , Masculino , Persona de Mediana Edad , Resultado del Tratamiento
18.
Europace ; 11(5): 565-70, 2009 May.
Artículo en Inglés | MEDLINE | ID: mdl-19251707

RESUMEN

AIMS: We compared a newly developed irrigated gold tip electrode ablation catheter and a gold tip 4 and 8 mm catheter with the corresponding platinum-iridium (Pt) tip catheters in an in vitro setting. METHODS AND RESULTS: In a flow chamber simulating physiological flow conditions, radiofrequency catheter ablation was performed on tissue samples of porcine endomyocardium and liver. Lesion depth, energy and temperature delivery, and popping frequency were determined. Two hundred and fifty-three ablations were conducted. Four and eight millimetre, gold tip electrode catheters produced significantly deeper lesions compared with the Pt tip electrode (liver 4 mm: 4.67 +/- 1.7 vs. 2.9 +/- 1.0 mm, P < 0.0001; endomyocardium 4 mm: 3.88 +/- 1.1 vs. 2.81 +/- 0.7 mm, P < 0.001; liver 8 mm: 3.98 +/- 1.0 vs. 2.03 +/- 1.1 mm, P < 0.001; endomyocardium 8 mm: 4.00 +/- 0.9 vs. 3.39 +/- 0.8 mm, P < 0.001) and correlated with the amount of energy delivery. Popping frequency was significantly higher in gold tip electrodes. In irrigated tip electrodes, there was no difference in the lesion depth comparing gold with Pt (liver: 5.18 +/- 0.7 vs. 5.01 +/- 0.7 mm, P = ns; endomyocardium: 4.89 +/- 0.7 vs. 4.78 +/- 0.8 mm, P = ns). There was a trend towards less popping in the gold tip electrode. CONCLUSION: Both 4 and 8 mm not-irrigated gold tip catheters produced deeper lesions than the corresponding Pt tip catheter. In irrigated tip catheters, gold and Pt tip material did not show differences in the lesion depth.


Asunto(s)
Ablación por Catéter/instrumentación , Ablación por Catéter/métodos , Oro , Iridio , Platino (Metal) , Animales , Procedimientos Quirúrgicos Cardíacos/instrumentación , Procedimientos Quirúrgicos Cardíacos/métodos , Electrodos , Técnicas In Vitro , Hígado/cirugía , Modelos Animales , Porcinos
19.
J Interv Card Electrophysiol ; 22(2): 155-9, 2008 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-18386170

RESUMEN

Catheter ablation has emerged as an excellent treatment option for atrial fibrillation especially in patients with paroxysmal AF. Several obstacles however remain regarding ablation strategies for persistent and chronic AF. In this setting, adequate success rates can only be achieved with left atrial ablation in addition to complete PV isolation. Important techniques in this regard are mapping of complex fractionated atrial electrograms as well as identification of atrial sites serving as sources of persistent AF. Other mapping techniques reviewed in this article are rapid geometry acquisition with spiral catheters and the Ensite/NAVX system, the 64-pole Constellation basket catheter as well as the MESH Mapper catheter.


Asunto(s)
Fibrilación Atrial/cirugía , Cateterismo Cardíaco/métodos , Ablación por Catéter , Electrocardiografía/métodos , Cirugía Asistida por Computador/métodos , Mapeo del Potencial de Superficie Corporal/métodos , Humanos , Venas Pulmonares/cirugía
20.
Am Heart J ; 152(2): 362.e1-5, 2006 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-16875923

RESUMEN

BACKGROUND: According to present knowledge, pulmonary vein isolation (PVI) bears a low interventional risk and has a high feasibility. For completion of PVI, left atrial access is achieved via single or double transseptal puncture. We sought to determine the incidence and echocardiographic characteristics of persistent iatrogenic atrial septal defect (iASD) after PVI. Further objectives were to define clinical and periprocedural risk factors for the development of iASD. METHODS: Every patient admitted for PVI at our hospital was screened for eligibility for study participation. Exclusion criteria were inability for undergoing transesophageal echocardiography, preexisting atrial septal defect, open-heart surgery or another transseptal procedure during the follow-up period. Transesophageal echocardiography was performed before PVI and after 9 months. Interatrial shunt was characterized by echocardiographic parameters; right-to-left-shunting (RLS) was quantified by contrast echocardiography. RESULTS: Forty-two patients were included, 27 patients underwent PVI with single transseptal puncture and additional advancement of a second electrophysiologic catheter (group A) 15 patients underwent PVI with double transseptal puncture (group B). In 8 patients of group A, iASD persisted after the follow-up period, including 6 patients with distinct RLS. We saw no iASD in group B (P = .011, CI -0.79 to -0.11). Preprocedural pulmonary artery pressure was significantly higher in patients with iASD and accompanying RLS, compared with patients with iASD and no evidence of RLS (23.75 +/- 0.50 vs 17.59 +/- 5.82, P = .048, CI 0.048-12.27). CONCLUSION: This is the first study that demonstrates a high incidence of long-term persistent iatrogenic atrial septal defect with RLS after PVI. All interatrial shunts occurred after single transseptal puncture with passage of 2 electrophysiologic catheters into the left atrium. Increased preprocedural pulmonary artery pressure seems to promote the occurrence of RLS across iASD.


Asunto(s)
Cateterismo Cardíaco/efectos adversos , Defectos del Tabique Interatrial/etiología , Venas Pulmonares/cirugía , Punciones/efectos adversos , Adulto , Procedimientos Quirúrgicos Cardíacos/métodos , Ecocardiografía Doppler en Color , Ecocardiografía Transesofágica , Técnicas Electrofisiológicas Cardíacas , Femenino , Defectos del Tabique Interatrial/diagnóstico por imagen , Tabiques Cardíacos/diagnóstico por imagen , Humanos , Enfermedad Iatrogénica , Masculino , Persona de Mediana Edad , Punciones/métodos , Volumen Sistólico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA