Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 41
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Mol Psychiatry ; 29(5): 1440-1449, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38302561

RESUMEN

Schizophrenia (SZ) is a serious mental illness and neuropsychiatric brain disorder with behavioral symptoms that include hallucinations, delusions, disorganized behavior, and cognitive impairment. Regulation of such behaviors requires utilization of neurotransmitters released to mediate cell-cell communication which are essential to brain functions in health and disease. We hypothesized that SZ may involve dysregulation of neurotransmitters secreted from neurons. To gain an understanding of human SZ, induced neurons (iNs) were derived from SZ patients and healthy control subjects to investigate peptide neurotransmitters, known as neuropeptides, which represent the major class of transmitters. The iNs were subjected to depolarization by high KCl in the culture medium and the secreted neuropeptides were identified and quantitated by nano-LC-MS/MS tandem mass spectrometry. Several neuropeptides were identified from schizophrenia patient-derived neurons, including chromogranin B (CHGB), neurotensin, and natriuretic peptide. Focusing on the main secreted CHGB neuropeptides, results revealed differences in SZ iNs compared to control iN neurons. Lower numbers of distinct CHGB peptides were found in the SZ secretion media compared to controls. Mapping of the peptides to the CHGB precursor revealed peptides unique to either SZ or control, and peptides common to both conditions. Also, the iNs secreted neuropeptides under both KCl and basal (no KCl) conditions. These findings are consistent with reports that chromogranin B levels are reduced in the cerebrospinal fluid and specific brain regions of SZ patients. These findings suggest that iNs derived from SZ patients can model the decreased CHGB neuropeptides observed in human SZ.


Asunto(s)
Cromogranina B , Neuronas , Neuropéptidos , Neurotransmisores , Esquizofrenia , Humanos , Esquizofrenia/metabolismo , Neuropéptidos/metabolismo , Neuronas/metabolismo , Cromogranina B/metabolismo , Masculino , Neurotransmisores/metabolismo , Femenino , Espectrometría de Masas en Tándem/métodos , Adulto , Persona de Mediana Edad , Neurotensina/metabolismo , Células Cultivadas , Encéfalo/metabolismo
2.
Mol Cell Proteomics ; 19(6): 1017-1034, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32295833

RESUMEN

Accumulation and propagation of hyperphosphorylated Tau (p-Tau) is a common neuropathological hallmark associated with neurodegeneration of Alzheimer's disease (AD), frontotemporal dementia and parkinsonism linked to chromosome 17 (FTDP-17), and related tauopathies. Extracellular vesicles, specifically exosomes, have recently been demonstrated to participate in mediating Tau propagation in brain. Exosomes produced by human induced pluripotent stem cell (iPSC)-derived neurons expressing mutant Tau (mTau), containing the P301L and V337M Tau mutations of FTDP-17, possess the ability to propagate p-Tau pathology after injection into mouse brain. To gain an understanding of the mTau exosome cargo involved in Tau pathogenesis, these pathogenic exosomes were analyzed by proteomics and bioinformatics. The data showed that mTau expression dysregulates the exosome proteome to result in 1) proteins uniquely present only in mTau, and not control exosomes, 2) the absence of proteins in mTau exosomes, uniquely present in control exosomes, and 3) shared proteins which were significantly upregulated or downregulated in mTau compared with control exosomes. Notably, mTau exosomes (not control exosomes) contain ANP32A (also known as I1PP2A), an endogenous inhibitor of the PP2A phosphatase which regulates the phosphorylation state of p-Tau. Several of the mTau exosome-specific proteins have been shown to participate in AD mechanisms involving lysosomes, inflammation, secretases, and related processes. Furthermore, the mTau exosomes lacked a substantial portion of proteins present in control exosomes involved in pathways of localization, vesicle transport, and protein binding functions. The shared proteins present in both mTau and control exosomes represented exosome functions of vesicle-mediated transport, exocytosis, and secretion processes. These data illustrate mTau as a dynamic regulator of the biogenesis of exosomes to result in acquisition, deletion, and up- or downregulation of protein cargo to result in pathogenic mTau exosomes capable of in vivo propagation of p-Tau neuropathology in mouse brain.


Asunto(s)
Enfermedad de Alzheimer/metabolismo , Exosomas/metabolismo , Neuronas/metabolismo , Proteómica , Proteínas tau/metabolismo , Enfermedad de Alzheimer/genética , Animales , Encéfalo/metabolismo , Encéfalo/patología , Células Cultivadas , Cromatografía Liquida , Biología Computacional , Exosomas/patología , Ontología de Genes , Humanos , Células Madre Pluripotentes Inducidas/metabolismo , Mutación , Neuronas/patología , Proteínas Nucleares/metabolismo , Fosforilación , Unión Proteica , Mapas de Interacción de Proteínas , Proteína Fosfatasa 2/antagonistas & inhibidores , Proteína Fosfatasa 2/metabolismo , Proteínas de Unión al ARN/metabolismo , Espectrometría de Masas en Tándem , Proteínas tau/genética
3.
Rapid Commun Mass Spectrom ; 35 Suppl 1: e8793, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32220130

RESUMEN

RATIONALE: Examining surface protein conformations, and especially achieving this with spatial resolution, is an important goal. The recently discovered ionization processes offer spatial-resolution measurements similar to matrix-assisted laser desorption/ionization (MALDI) and produce charge states similar to electrospray ionization (ESI) extending higher-mass protein applications directly from surfaces on high-performance mass spectrometers. Studying a well-interrogated protein by ion mobility spectrometry-mass spectrometry (IMS-MS) to access effects on structures using a solid vs. solvent matrix may provide insights. METHODS: Ubiquitin was studied by IMS-MS using new ionization processes with commercial and homebuilt ion sources and instruments (Waters SYNAPT G2(S)) and homebuilt 2 m drift-tube instrument; MS™ sources). Mass-to-charge and drift-time (td )-measurements are compared for ubiquitin ions obtained by inlet and vacuum ionization using laserspray ionization (LSI), matrix- (MAI) and solvent-assisted ionization (SAI), respectively, and compared with those from ESI under conditions that are most comparable. RESULTS: Using the same solution conditions with SYNAPT G2(S) instruments, td -distributions of various ubiquitin charge states from MAI, LSI, and SAI are similar to those from ESI using a variety of solvents, matrices, extraction voltages, a laser, and temperature only, showing subtle differences in more compact features within the elongated distribution of structures. However, on a homebuilt drift-tube instrument, within the elongated distribution of structures, both similar and different td -distributions are observed for ubiquitin ions obtained by MAI and ESI. MAI-generated ions are frequently narrower in their td -distributions. CONCLUSIONS: Direct comparisons between ESI and the new ionization methods operational directly from surfaces suggest that the protein in its solution structure prior to exposure to the ionization event is either captured (frozen out) at the time of crystallization, or that the protein in the solid matrix is associated with sufficient solvent to maintain the solution structure, or, alternatively, that the observed structures are those related to what occurs in the gas phase with ESI- or MAI-generated ions and not with the solution structures.


Asunto(s)
Espectrometría de Movilidad Iónica/métodos , Espectrometría de Masas/métodos , Ubiquitina/química , Gases/química , Iones/química , Solventes/química
4.
Rapid Commun Mass Spectrom ; 35 Suppl 1: e8829, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32402102

RESUMEN

RATIONALE: The developments of new ionization technologies based on processes previously unknown to mass spectrometry (MS) have gained significant momentum. Herein we address the importance of understanding these unique ionization processes, demonstrate the new capabilities currently unmet by other methods, and outline their considerable analytical potential. METHODS: The inlet and vacuum ionization methods of solvent-assisted ionization (SAI), matrix-assisted ionization (MAI), and laserspray ionization can be used with commercial and dedicated ion sources producing ions from atmospheric or vacuum conditions for analyses of a variety of materials including drugs, lipids, and proteins introduced from well plates, pipet tips and plate surfaces with and without a laser using solid or solvent matrices. Mass spectrometers from various vendors are employed. RESULTS: Results are presented highlighting strengths relative to ionization methods of electrospray ionization (ESI) and matrix-assisted laser desorption/ionization. We demonstrate the utility of multi-ionization platforms encompassing MAI, SAI, and ESI and enabling detection of what otherwise is missed, especially when directly analyzing mixtures. Unmatched robustness is achieved with dedicated vacuum MAI sources with mechanical introduction of the sample to the sub-atmospheric pressure (vacuum MAI). Simplicity and use of a wide array of matrices are attained using a conduit (inlet ionization), preferably heated, with sample introduction from atmospheric pressure. Tissue, whole blood, urine (including mouse, chicken, and human origin), bacteria strains and chemical on-probe reactions are analyzed directly and, especially in the case of vacuum ionization, without concern of carryover or instrument contamination. CONCLUSIONS: Examples are provided highlighting the exceptional analytical capabilities associated with the novel ionization processes in MS that reduce operational complexity while increasing speed and robustness, achieving mass spectra with low background for improved sensitivity, suggesting the potential of this simple ionization technology to drive MS into areas currently underserved, such as clinical and medical applications.


Asunto(s)
Espectrometría de Masas , Animales , Bacterias/química , Diseño de Equipo , Humanos , Espectrometría de Masas/instrumentación , Espectrometría de Masas/métodos , Ratones , Imagen Molecular/instrumentación , Imagen Molecular/métodos , Vacio
5.
Neuromodulation ; 24(1): 22-32, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32157770

RESUMEN

OBJECTIVES: Spinal cord stimulation (SCS) provides relief for patients suffering from chronic neuropathic pain although its mechanism may not be as dependent on electrical interference as classically considered. Recent evidence has been growing regarding molecular changes that are induced by SCS as being a key player in reversing the pain process. Here, we observed the effect of SCS on altering protein expression in spinal cord tissue using a proteomic analysis approach. METHODS: A microlead was epidurally implanted following induction of an animal neuropathic pain model. After the model was established, stimulation was applied for 72 hours continuously followed by tissue collection and proteomic analysis via tandem mass spectroscopy. Identified proteins were run through online data bases for protein identification and classification of biological processes. RESULTS: A significant improvement in mechanical sensitivity was observed following 48 hours of SCS therapy. Proteomic analysis identified 5840 proteins, of which 155 were significantly affected by SCS. Gene ontology data bases indicated that a significant number of proteins were associated to stress response, oxidation/reduction, or extracellular matrix pathways. Additionally, many of the proteins identified also play a role in neuron-glial interactions and are involved in nociception. CONCLUSIONS: The development of an injury unbalances the proteome of the local neural tissue, neurons, and glial cells, and shifts the proteomic profile to a pain producing state. This study demonstrates the reversal of the injury-induced proteomic state by applying conventional SCS therapy. Additional studies looking at variations in electrical parameters are needed to optimize SCS.


Asunto(s)
Neuralgia , Estimulación de la Médula Espinal , Animales , Modelos Animales de Enfermedad , Humanos , Neuralgia/etiología , Neuralgia/terapia , Proteómica , Médula Espinal
6.
Molecules ; 25(18)2020 Sep 06.
Artículo en Inglés | MEDLINE | ID: mdl-32899982

RESUMEN

Proteomic technologies have identified 234 peptidases in plasma but little quantitative information about the proteolytic activity has been uncovered. In this study, the substrate profile of plasma proteases was evaluated using two nano-LC-ESI-MS/MS methods. Multiplex substrate profiling by mass spectrometry (MSP-MS) quantifies plasma protease activity in vitro using a global and unbiased library of synthetic peptide reporter substrates, and shotgun peptidomics quantifies protein degradation products that have been generated in vivo by proteases. The two approaches gave complementary results since they both highlight key peptidase activities in plasma including amino- and carboxypeptidases with different substrate specificity profiles. These assays provide a significant advantage over traditional approaches, such as fluorogenic peptide reporter substrates, because they can detect active plasma proteases in a global and unbiased manner, in comparison to detecting select proteases using specific reporter substrates. We discovered that plasma proteins are cleaved by endoproteases and these peptide products are subsequently degraded by amino- and carboxypeptidases. The exopeptidases are more active and stable in plasma and therefore were found to be the most active proteases in the in vitro assay. The protocols presented here set the groundwork for studies to evaluate changes in plasma proteolytic activity in shock.


Asunto(s)
Péptido Hidrolasas/sangre , Espectrometría de Masas en Tándem/métodos , Secuencia de Aminoácidos , Animales , Péptido Hidrolasas/química , Proteómica , Especificidad por Sustrato , Porcinos
7.
J Proteome Res ; 18(8): 3156-3165, 2019 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-31200599

RESUMEN

Extracellular matrix (ECM) is an important component of the pancreatic microenvironment which regulates ß cell proliferation, differentiation, and insulin secretion. Protocols have recently been developed for the decellularization of the human pancreas to generate functional scaffolds and hydrogels. In this work, we characterized human pancreatic ECM composition before and after decellularization using isobaric dimethylated leucine (DiLeu) labeling for relative quantification of ECM proteins. A novel correction factor was employed in the study to eliminate the bias introduced during sample preparation. In comparison to the commonly employed sample preparation methods (urea and FASP) for proteomic analysis, a recently developed surfactant and chaotropic agent assisted sequential extraction/on pellet digestion (SCAD) protocol has provided an improved strategy for ECM protein extraction of human pancreatic ECM matrix. The quantitative proteomic results revealed the preservation of matrisome proteins while most of the cellular proteins were removed. This method was compared with a well-established label-free quantification (LFQ) approach which rendered similar expressions of different categories of proteins (collagens, ECM glycoproteins, proteoglycans, etc.). The distinct expression of ECM proteins was quantified comparing adult and fetal pancreas ECM, shedding light on the correlation between matrix composition and postnatal ß cell maturation. Despite the distinct profiles of different subcategories in the native pancreas, the distribution of matrisome proteins exhibited similar trends after the decellularization process. Our method generated a large data set of matrisome proteins from a single tissue type. These results provide valuable insight into the possibilities of constructing a bioengineered pancreas. It may also facilitate better understanding of the potential roles that matrisome proteins play in postnatal ß cell maturation.


Asunto(s)
Proteínas de la Matriz Extracelular/genética , Páncreas/metabolismo , Proteoglicanos/genética , Proteómica , Colágeno/genética , Colágeno/metabolismo , Proteínas de la Matriz Extracelular/aislamiento & purificación , Humanos , Hidrogeles/química , Proteoglicanos/aislamiento & purificación
8.
Anal Bioanal Chem ; 410(3): 1007-1017, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28900710

RESUMEN

Matrix-assisted ionization (MAI) is a recently developed ionization technique that produces multiply charged ions on either electrospray ionization (ESI) or matrix-assisted laser desorption/ionization (MALDI) platform without the need of high voltage or laser ablation. In this study, MAI has been coupled to a high resolution accurate mass (HRAM) hybrid instrument, the Orbitrap Elite mass spectrometer, with electron transfer dissociation (ETD) module for fast peptide and intact protein characterization. The softness of MAI process preserves labile post-translational modifications (PTM) and allows fragmentation and localization by ETD. Moreover, MAI on ESI platform allows rapid sample preparation and analysis (~ 1 min/sample) due to the easiness of sample introduction. It significantly improves the throughput compared to ESI direct infusion and MAI on MALDI platform, which usually takes more than 10 min/sample. Intact protein standards, protein mixtures, and neural tissue extracts have been characterized using this instrument platform with both full MS and MS/MS (CID, HCD, and ETD) analyses. Furthermore, the performances of ESI, MALDI, and MAI on both platforms have been tested to provide a systematic comparison among these techniques. With improved ETD performance and PTM analysis capabilities, we anticipate that the HRAM MAI-MS with ETD module will offer greater utilities in large molecule characterization with enhanced speed and coverage. These advancements will enable promising applications in bottom-up and top-down protein analyses. Graphical abstract Matrix-assisted ionization (MAI) for characterizing intact proteins and post-translational modifications with representative mass spectra from intact proteins.


Asunto(s)
Proteínas/química , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/instrumentación , Espectrometría de Masas en Tándem/instrumentación , Secuencia de Aminoácidos , Animales , Transporte de Electrón , Diseño de Equipo , Femenino , Glicopéptidos/análisis , Fosfopéptidos/análisis , Procesamiento Proteico-Postraduccional , Ratas Sprague-Dawley
9.
Anal Chem ; 89(2): 1138-1146, 2017 01 17.
Artículo en Inglés | MEDLINE | ID: mdl-28194987

RESUMEN

Mass spectrometry-based stable isotope labeling has become a key technology for protein and small-molecule analyses. We developed a multiplexed quantification method for simultaneous proteomics and amine metabolomics analyses via nano reversed-phase liquid chromatography-tandem mass spectrometry (nanoRPLC-MS/MS), called mass defect-based N,N-dimethyl leucine (mdDiLeu) labeling. The duplex mdDiLeu reagents were custom-synthesized with a mass difference of 20.5 mDa, arising from the subtle variation in nuclear binding energy between the two DiLeu isotopologues. Optimal MS resolving powers were determined to be 240K for labeled peptides and 120K for labeled metabolites on the Orbitrap Fusion Lumos instrument. The mdDiLeu labeling does not suffer from precursor interference and dynamic range compression, providing excellent accuracy for MS1-centric quantification. Quantitative information is only revealed at high MS resolution without increasing spectrum complexity and overlapping isotope distribution. Chromatographic performance of polar metabolites was dramatically improved by mdDiLeu labeling with modified hydrophobicity, enhanced ionization efficiency, and picomole levels of detection limits. Paralleled proteomics and amine metabolomics analyses using mdDiLeu were systematically evaluated and then applied to pancreatic cancer cells.


Asunto(s)
Aminas/metabolismo , Leucina/análogos & derivados , Metabolómica/métodos , Neoplasias Pancreáticas/metabolismo , Proteínas/metabolismo , Proteómica/métodos , Aminas/análisis , Línea Celular Tumoral , Cromatografía de Fase Inversa/métodos , Humanos , Leucina/análisis , Leucina/metabolismo , Metilación , Proteínas/análisis , Espectrometría de Masas en Tándem/métodos
10.
J Proteome Res ; 15(9): 3420-31, 2016 09 02.
Artículo en Inglés | MEDLINE | ID: mdl-27457343

RESUMEN

Isobaric labeling has become a widespread tool for quantitative proteomic studies. Here, we report the development and evaluation of several dimethylated amino acids as novel isobaric tags for quantitative proteomics. Four-plex dimethylated alanine (DiAla), valine (DiVal), and leucine (DiLeu) have been synthesized, sharing common features of peptide tagging and reporter ion production. DiAla and DiLeu are shown to achieve complete labeling. These two tags' impacts on peptide fragmentation and quantitation are further evaluated using HEK293 cell lysate. DiAla labeling generates more abundant backbone fragmentation whereas DiLeu labeling produces more intense reporter ions. Nonetheless, both tags enable accurate quantitative analysis of HEK293 cell proteomes. DiAla and DiLeu tags are then applied to study the TGF-ß/Smad3 pathway with four differentially treated mouse vascular smooth muscle (MOVAS) cells. Our MS data reveal proteome-wide changes of AdSmad3 as compared to the GFP control, consistent with previous findings of causing smooth muscle cell (SMC) dedifferentiation.1 Additionally, the other two novel mutations on the hub protein Smad3, Y226A, and D408H, show compromised TGF-ß/Smad3-dependent gene transcription and reversed phenotypic switch. These results are further corroborated with Western blotting and demonstrate that the novel DiAla and DiLeu isobaric tagging reagents provide useful tools for multiplex quantitative proteomics.


Asunto(s)
Proteómica/métodos , Transducción de Señal , Proteína smad3/metabolismo , Coloración y Etiquetado/métodos , Factor de Crecimiento Transformador beta/metabolismo , Alanina/análogos & derivados , Aminoácidos/síntesis química , Aminoácidos/química , Animales , Células HEK293 , Humanos , Leucina/análogos & derivados , Metilación , Ratones , Músculo Liso Vascular/citología , Valina/análogos & derivados
11.
Analyst ; 141(16): 4863-9, 2016 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-27434776

RESUMEN

Ion mobility-mass spectrometry (IM-MS) is often employed to look at the secondary, tertiary, and quaternary structures of naked peptides and proteins in the gas-phase. Recently, it has offered a unique glimpse into proline-containing peptides and their cis/trans Xxx-Pro isomers. An experimental "signature" has been identified wherein a proline-containing peptide has its Pro residues substituted with another amino acid and the presence or absence of conformations in the IM-MS spectra is observed. Despite the high probability that one could attribute these conformations to cis/trans isomers, it is also possible that cis/trans isomers are not the cause of the additional conformations in proline-containing peptides. However, the experimental evidence of such a system has not been demonstrated or reported. Herein, we present the IM-MS analysis of Neuropeptide Y's wild-type (WT) signal sequence and Leu7Pro (L7P) mutant. Although comparison of arrival times and collision cross-sections of [M + 4H](4+) ions yields the cis/trans "signature", molecular dynamics indicates that a cis-Pro7 is not very stable and that trans-Pro7 conformations of the same cross-section arise with equal frequency. We believe that this work further underscores the importance of theoretical calculations in IM-MS structural assignments.

12.
Environ Sci Technol ; 50(13): 7095-105, 2016 07 05.
Artículo en Inglés | MEDLINE | ID: mdl-27247993

RESUMEN

Prions, the etiological agents in transmissible spongiform encephalopathies, exhibit remarkable resistance to most methods of inactivation that are effective against conventional pathogens. Prions are composed of pathogenic conformers of the prion protein (PrP(TSE)). Some prion diseases are transmitted, in part, through environmental routes. The recalcitrance of prions to inactivation may lead to a persistent reservoir of infectivity that contributes to the environmental maintenance of epizootics. At present, few methods exist to remediate prion-contaminated land surfaces. Here we conducted a proof-of-principle study to examine the ability of peroxymonosulfate to degrade PrP(TSE). We find that peroxymonosulfate rapidly degrades PrP(TSE) from two species. Transition-metal-catalyzed decomposition of peroxymonosulfate to produce sulfate radicals appears to enhance degradation. We further demonstrate that exposure to peroxymonosulfate significantly reduced PrP(C) to PrP(TSE) converting ability as measured by protein misfolding cyclic amplification, used as a proxy for infectivity. Liquid chromatography-tandem mass spectrometry revealed that exposure to peroxymonosulfate results in oxidative modifications to methionine and tryptophan residues. This study indicates that peroxymonosulfate may hold promise for decontamination of prion-contaminated surfaces.


Asunto(s)
Proteínas Priónicas , Priones/química , Oxidación-Reducción , Enfermedades por Prión
13.
Crit Rev Biochem Mol Biol ; 48(5): 409-29, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23883414

RESUMEN

Mass spectrometry (MS) continues to improve at a rapid pace as most prominently witnessed for mass analyzers and fragmentation technology. Ionization methods have also seen resurgence with ambient ionization approaches gaining a foothold because they often provide a convenient and direct means of sample analysis. Nevertheless, a vast majority of biological analyses using MS apply electrospray ionization or matrix-assisted laser desorption/ionization, methods introduced in the 1980s, or variants thereof. To further advance applications by MS such as protein characterization, and, for example, addressing their location within specific cell types, the progress in mass analyzer and fragmentation technology needs to be matched with similar advances in ionization technology. It is imperative to seek ionization methods that more efficiently convert molecules, to gas-phase ions in a way that allows high transfer efficiency to the mass analyzer and subsequently the detector to achieve a more complete picture of sample composition. This review provides a snapshot of fundamental aspects of new ionization methods and potential biological and medical applications.


Asunto(s)
Espectrometría de Masa por Ionización de Electrospray/métodos , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Diagnóstico por Imagen , Genómica , Humanos
14.
Anal Chem ; 86(6): 2972-81, 2014 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-24328107

RESUMEN

Traditionally, the d-amino acid containing peptide (DAACP) candidate can be discovered by observing the differences of biological activity and chromatographic retention time between the synthetic peptides and naturally occurring peptides. However, it is difficult to determine the exact position of d-amino acid in the DAACP candidates. Herein, we developed a novel site-specific strategy to rapidly and precisely localize d-amino acids in peptides by ion mobility spectrometry (IMS) analysis of mass spectrometry (MS)-generated epimeric fragment ions. Briefly, the d/l-peptide epimers were separated by online reversed-phase liquid chromatography and fragmented by collision-induced dissociation (CID), followed by IMS analysis. The epimeric fragment ions resulting from d/l-peptide epimers exhibit conformational differences, thus showing different mobilities in IMS. The arrival time shift between the epimeric fragment ions was used as criteria to localize the d-amino acid substitution. The utility of this strategy was demonstrated by analysis of peptide epimers with different molecular sizes, [d-Trp]-melanocyte-stimulating hormone, [d-Ala]-deltorphin, [d-Phe]-achatin-I, and their counterparts that contain all-l amino acids. Furthermore, the crustacean hyperglycemia hormones (CHHs, 8.5 kDa) were isolated from the American lobster Homarus americanus and identified by integration of MS-based bottom-up and top-down sequencing approaches. The IMS data acquired using our novel site-specific strategy localized the site of isomerization of l- to d-Phe at the third residue of the CHHs from the N-terminus. Collectively, this study demonstrates a new method for discovery of DAACPs using IMS technique with the ability to localize d-amino acid residues.


Asunto(s)
Aminoácidos/química , Análisis Espectral/métodos , Secuencia de Aminoácidos , Animales , Calibración , Cromatografía Liquida , Crustáceos , Isomerismo , Datos de Secuencia Molecular , Espectrometría de Masas en Tándem
15.
Anal Chem ; 86(6): 2917-24, 2014 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-24313304

RESUMEN

Peptide sequence scrambling during mass spectrometry-based gas-phase fragmentation analysis causes misidentification of peptides and proteins. Thus, there is a need to develop an efficient approach to probing the gas-phase fragment ion isomers related to sequence scrambling and the underlying fragmentation mechanism, which will facilitate the development of bioinformatics algorithm for proteomics research. Herein, we report on the first use of electron transfer dissociation (ETD)-produced diagnostic fragment ions to probe the components of gas-phase peptide fragment ion isomers. In combination with ion mobility spectrometry (IMS) and formaldehyde labeling, this novel strategy enables qualitative and quantitative analysis of b-type fragment ion isomers. ETD fragmentation produced diagnostic fragment ions indicative of the precursor ion isomer components, and subsequent IMS analysis of b ion isomers provided their quantitative and structural information. The isomer components of three representative b ions (b9, b10, and b33 from three different peptides) were accurately profiled by this method. IMS analysis of the b9 ion isomers exhibited dynamic conversion among these structures. Furthermore, molecular dynamics simulation predicted theoretical drift time values, which were in good agreement with experimentally measured values. Our results strongly support the mechanism of peptide sequence scrambling via b ion cyclization, and provide the first experimental evidence to support that the conversion from molecular precursor ion to cyclic b ion (M → (c)b) pathway is less energetically (or kinetically) favored.


Asunto(s)
Gases/química , Péptidos/química , Algoritmos , Secuencia de Aminoácidos , Isomerismo , Simulación de Dinámica Molecular , Datos de Secuencia Molecular
16.
Rapid Commun Mass Spectrom ; 28(9): 1051-1060, 2014 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-24677527

RESUMEN

RATIONALE: Isobaric tandem mass tags are an attractive alternative to mass difference tags and label-free approaches for quantitative proteomics due to the high degree of multiplexing that can be performed with their implementation. A drawback of tandem mass tags are that the co-isolation and co-fragmentation of labeled peptide precursors can result in chimeric tandem mass (MS/MS) spectra that can underestimate the fold-change expression of each peptide. Ion mobility (IM) separations coupled to quadrupole time-of-flight (Q-TOF) instruments have the potential to mitigate MS/MS spectra chimeracy since IM-MS has the ability to separate ions based on charge, m/z, and collision cross section (CCS). METHODS: Two complex protein mixtures, labeled with DiLeu isobaric tandem mass tags in opposite ratios, were mixed together and analyzed by data-dependent LC/IM-MS/MS. The accuracy of reporters from interfering pairs was compared with and without IM separation. RESULTS: IM separation was able to mitigate isobaric interference from differentially charged interfering ion pairs, as well as pairs of the same charge. Of the eight example precursors shown, only one had reporters that remained compressed below the significance threshold after IM separation. CONCLUSIONS: The results of this investigation demonstrate proof-of-principle that IM separation of tagged precursors prior to MS/MS fragmentation can help mitigate quantitative inaccuracies caused by isobaric interference. Future improvements of the method would include software for automated correction and use of higher resolution IM instrumentations.


Asunto(s)
Espectrometría de Masas en Tándem/métodos , Animales , Cromatografía Liquida , Mamíferos , Fragmentos de Péptidos/análisis , Fragmentos de Péptidos/química , Fragmentos de Péptidos/aislamiento & purificación , Proteínas/análisis , Proteínas/química , Proteínas/aislamiento & purificación
17.
Mol Cell Proteomics ; 11(12): 1951-64, 2012 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23028060

RESUMEN

A complete understanding of the biological functions of large signaling peptides (>4 kDa) requires comprehensive characterization of their amino acid sequences and post-translational modifications, which presents significant analytical challenges. In the past decade, there has been great success with mass spectrometry-based de novo sequencing of small neuropeptides. However, these approaches are less applicable to larger neuropeptides because of the inefficient fragmentation of peptides larger than 4 kDa and their lower endogenous abundance. The conventional proteomics approach focuses on large-scale determination of protein identities via database searching, lacking the ability for in-depth elucidation of individual amino acid residues. Here, we present a multifaceted MS approach for identification and characterization of large crustacean hyperglycemic hormone (CHH)-family neuropeptides, a class of peptide hormones that play central roles in the regulation of many important physiological processes of crustaceans. Six crustacean CHH-family neuropeptides (8-9.5 kDa), including two novel peptides with extensive disulfide linkages and PTMs, were fully sequenced without reference to genomic databases. High-definition de novo sequencing was achieved by a combination of bottom-up, off-line top-down, and on-line top-down tandem MS methods. Statistical evaluation indicated that these methods provided complementary information for sequence interpretation and increased the local identification confidence of each amino acid. Further investigations by MALDI imaging MS mapped the spatial distribution and colocalization patterns of various CHH-family neuropeptides in the neuroendocrine organs, revealing that two CHH-subfamilies are involved in distinct signaling pathways.


Asunto(s)
Proteínas de Artrópodos/química , Braquiuros , Hormonas de Invertebrados/química , Proteínas del Tejido Nervioso/química , Análisis de Secuencia de Proteína/métodos , Secuencia de Aminoácidos , Animales , Espectrometría de Masas , Datos de Secuencia Molecular , Conformación Proteica , Procesamiento Proteico-Postraduccional , Alineación de Secuencia , Transducción de Señal , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción
18.
J Mass Spectrom ; 59(6): e5018, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38736378

RESUMEN

This paper covers direct sub-atmospheric pressure ionization mass spectrometry (MS). The discovery, applications, and mechanistic aspects of novel ionization processes for use in MS that are not based on the high-energy input from voltage, laser, and/or high temperature but on sublimation/evaporation within a region linking a higher to lower pressure and modulated by heat and collisions, are discussed, including how this new reality has guided a series of discoveries, instrument developments, and commercialization. A research focus, inter alia, is on how best to understand, improve, and use these novel ionization processes, which convert volatile and nonvolatile compounds from solids (sublimation) or liquids (evaporation) into gas-phase ions for analysis by MS providing reproducible, accurate, sensitive, and prompt results. Our perception on how these unprecedented versus traditional ionization processes/methods relate to each other, how they can be made to coexist on the same mass spectrometer, and an outlook on new and expanded applications (e.g., clinical, portable, fast, safe, and autonomous) is presented, and is based on ST's Opening lecture presentation at the Nordic Mass spectrometry Conference, Geilo, Norway, January 2023. Focus will be on matrix-assisted ionization (MAI) and solvent-assisted ionization (SAI) MS covering the period from 2010 to 2023; a potential paradigm shift in the making.

19.
MAbs ; 15(1): 2259289, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37742207

RESUMEN

Despite tyrosine sulfation being a relatively common post-translational modification (PTM) on the secreted proteins of higher eukaryotic organisms, there have been surprisingly few reports of this modification occurring in recombinant monoclonal antibodies (mAbs) expressed by mammalian cell lines and even less information regarding its potential impact on mAb efficacy and stability. This discrepancy is likely due to the extreme lability of this modification using many of the mass spectrometry methods typically used within the biopharmaceutical industry for PTM identification, as well as the possible misidentification as phosphorylation. Here, we identified sulfation on a single tyrosine residue located within the identical variable region sequence of a 2 + 1 bispecific mAbs heavy and heavy-heavy chains using a multi-enzymatic approach in combination with mass spectrometry analysis and examined its impact on binding, efficacy, and physical stability. Unlike previous reports, we found that tyrosine sulfation modestly decreased the mAb cell binding and T cell-mediated killing, primarily by increasing the rate of antigen disassociation as determined from surface plasmon resonance-binding experiments. We also found that, while this acidic modification had no significant impact on the mAb thermal stability, sulfation did modestly increase its rate of aggregation, presumably by lowering the mAb's colloidal stability as indicated by polyethylene glycol induced liquid-liquid phase separation experiments.


Asunto(s)
Anticuerpos Biespecíficos , Tirosina , Animales , Tirosina/química , Proteínas Recombinantes/metabolismo , Espectrometría de Masas , Anticuerpos Monoclonales/química , Línea Celular , Mamíferos/metabolismo
20.
J Lipid Res ; 53(7): 1390-8, 2012 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-22262808

RESUMEN

A new ionization method for the analysis of fragile gangliosides without undesired fragmentation or salt adduction is presented. In laserspray ionization inlet (LSII), the matrix/analyte sample is ablated at atmospheric pressure, and ionization takes place in the ion transfer capillary of the mass spectrometer inlet by a process that is independent of a laser wavelength or voltage. The softness of LSII allows the identification of gangliosides up to GQ1 with negligible sialic acid loss. This is of importance to the field of MS imaging, as undesired fragmentation has made it difficult to accurately map the spatial distribution of fragile ganglioside lipids in tissue. Proof-of-principle structural characterization of endogenous gangliosides using MS(n) fragmentation of multiply charged negative ions on a LTQ Velos and subsequent imaging of the GD1 ganglioside is demonstrated. This is the first report of multiply charged negative ions using inlet ionization. We find that GD1 is detected at higher levels in the mouse cortex and hippocampus compared with the thalamus. In LSII with the laser aligned in transmission geometry relative to the inlet, images were obtained in approximately 60 min using an inexpensive nitrogen laser.


Asunto(s)
Encéfalo/metabolismo , Gangliósidos/análisis , Rayos Láser , Animales , Ratones , Ratones Endogámicos C57BL , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA