Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 99(4): 1214-1224, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34936723

RESUMEN

OBJECTIVE: Our objective was to evaluate the impact of various blood pressures (BPs) on coronary perfusion and valvular hemodynamics following aortic valve replacement (AVR). BACKGROUND: Lower systolic and diastolic (SBP/DBP) pressures from the recommended optimal target range of SBP < 120-130 mmHg and DBP < 80 mmHg after AVR have been independently associated with increased cardiovascular and all-cause mortality. METHODS: The hemodynamic assessment of a 26 mm SAPIEN 3 transcatheter aortic valve (TAV), 29 mm Evolut R TAV, and 25 mm Magna Ease surgical aortic valve (SAV) was performed in a pulsed left heart simulator with varying SBP, DBP, and heart rate (HR) conditions (60 and 120 bpm) at 5 L/min cardiac output (CO). Average coronary flow (CF), effective orifice areas (EOAs), and valvulo-arterial impedance (Zva) were calculated. RESULTS: At HR of 60 bpm, at SBP < 120 mmHg and DBP < 60 mmHg, CF decreased below the physiological lower limit with several different valves. Zva and EOA were found to increase and decrease respectively with increasing SBP and DBP. The same results were found with an HR of 120 bpm. The trends of CF variation with BP were similar in all valves however the drop below the lower physiological CF limit was valve dependent. CONCLUSION: In a controlled in vitro system, with different aortic valve prostheses in place, CF decreased below the physiologic minimum when SBP and DBP were in the range targeted by blood pressure guidelines. Combined with recent observations from patients treated with AVR, these findings underscore the need for additional studies to identify the optimal BP in patients treated with AVR for AS.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Presión Sanguínea/fisiología , Hemodinámica , Humanos , Perfusión , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
2.
J Card Surg ; 37(11): 3935-3942, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36098378

RESUMEN

BACKGROUND: Combined on-pump coronary artery bypass (ONCAB) and surgical aortic valve replacement (SAVR) is the treatment of choice for concomitant severe aortic stenosis and coronary artery disease not amenable to percutaneous coronary intervention. Extensive aortic calcification and atheromatous disease may prohibit cardiopulmonary bypass and aortic cross-clamping. In these cases, anaortic off-pump coronary artery bypass (OPCAB) is a Class I (EACTS 2018) and Class IIA (AHA 2021) indication for surgical coronary revascularization. Transcatheter aortic valve replacement (TAVR) has similar benefits when compared with SAVR for this population (Partner 2 & 3). Herewith we describe a case series of concomitant Anaortic OPCAB and TAVR via the transfemoral approach for patients with coronary artery and valve disease considered too high risk for traditional coronary artery bypass grafting and SAVR due to severe aortic disease. METHODS/RESULTS: Eight patients underwent anaortic OPCAB and transfemoral TAVR during the same anesthetic in a hybrid operating room. Seven patients with multivessel disease had anaortic OPCAB via a sternotomy using composite grafts, one patient with LAD disease had anaortic OPCAB using a Da Vinci-assisted MIDCAB approach. All patients then had an Edwards Sapien 3 TAVR placed percutaneously via the common femoral artery. There was no 30 mortality or CVA in the series and all patients were discharged to home or a rehabilitation facility on Day 4-13. CONCLUSIONS: Combined anaortic OPCAB and transfemoral TAVR is a safe and feasible approach to treating concomitant extensive coronary artery disease and severe aortic stenosis. The aortic no-touch technique provides benefits in the elderly high-risk patients by reducing the risk of postoperative myocardial infarction and cerebrovascular stroke.


Asunto(s)
Estenosis de la Válvula Aórtica , Enfermedad de la Arteria Coronaria , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/cirugía , Humanos , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
3.
J Clin Gastroenterol ; 53(1): 23-28, 2019 01.
Artículo en Inglés | MEDLINE | ID: mdl-28858942

RESUMEN

GOALS: The goal of this study was to evaluate outcomes of colonoscopy in the setting of post myocardial infarction (MI) gastrointestinal bleeding (GIB) in a large population-based data set. BACKGROUND: The literature to substantiate the proposed safety of colonoscopy following an acute MI is limited. STUDY: The Nationwide Inpatient Sample (2007 to 2013) was utilized to identify all adult patients (age, 18 y or above) hospitalized with a primary diagnosis of ST-elevation MI and receiving left heart catheterization (STEMI-C). The outcomes of patients with concomitant diagnosis of GIB receiving endoscopic intervention with esophagogastroduodenoscopy (EGD) or colonoscopy postcatheterization were compared with those who did not. Primary outcomes including mortality, length of stay, and hospital costs were evaluated with univariate and multivariate analysis. RESULTS: There were 131,752 patients with post-STEMI-C GIB (5.35% of all STEMI-C patients) and same admission colonoscopy was performed in 1599 patients (1.21%). Although the prevalence of post-STEMI-C GIB increased from 4.27% in 2007 to 5.87% in 2013 (P<0.001), patients receiving colonoscopy decreased from 1.42% to 1.09% (P<0.001) over the course of the study period. Multivariate analysis revealed that patients receiving no endoscopic intervention [odds ratio, 3.61; 95% confidence interval: 1.57, 8.31] or EGD alone (OR, 2.70; 95% confidence interval: 1.12, 6.49) have higher mortality compared with those receiving colonoscopy. CONCLUSIONS: Same admission colonoscopy performed for post-STEMI-C GIB was associated with lower mortality. However, despite increased incidence of GIB in these patients during the study period, a lower percentage of patients received colonoscopy. These results suggest that colonoscopy is safe but underutilized in this setting.


Asunto(s)
Colonoscopía/métodos , Endoscopía del Sistema Digestivo/métodos , Hemorragia Gastrointestinal/diagnóstico , Infarto del Miocardio/fisiopatología , Anciano , Colonoscopía/efectos adversos , Femenino , Hemorragia Gastrointestinal/epidemiología , Costos de Hospital/estadística & datos numéricos , Hospitalización/estadística & datos numéricos , Humanos , Incidencia , Tiempo de Internación/estadística & datos numéricos , Masculino
4.
Heart Fail Clin ; 14(4): 625-634, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30266370

RESUMEN

Convergence of the fields of heart failure (HF) and interventional cardiology has led to the formation of a discipline referred to as interventional HF. Although the term may be applied to essentially any invasive procedure performed in patients with HF (eg, coronary angiography, percutaneous coronary intervention, invasive assessment of hemodynamics), it is more commonly reserved for the application of invasive diagnostic or therapeutic procedures to improve the clinical decision-making, functional status, and outcomes of HF patients. This article reviews developing modalities.


Asunto(s)
Cateterismo Cardíaco/métodos , Manejo de la Enfermedad , Insuficiencia Cardíaca , Monitorización Hemodinámica/métodos , Hemodinámica/fisiología , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/fisiopatología , Insuficiencia Cardíaca/terapia , Humanos
5.
J Card Fail ; 22(12): 988-995, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-27109621

RESUMEN

BACKGROUND: Left ventricular (LV) afterload is composed of systemic vascular resistance (SVR) and components of pulsatile load, including total arterial compliance (TAC), and reflection magnitude (RM). RM, which affects the LV systolic loading sequence, has been shown to strongly predict HF. Effective arterial elastance (Ea) is a commonly used parameter initially proposed to be a lumped index of resistive and pulsatile afterload. We sought to assess how various LV afterload parameters predict heart failure (HF) risk and whether RM predicts HF independently from subclinical atherosclerosis. METHODS: We studied 4345 MESA participants who underwent radial arterial tonometry and cardiac output (CO) measurements with the use of cardiac MRI. RM was computed as the ratio of the backward (Pb) to forward (Pf) waves. TAC was approximated as the ratio of stroke volume (SV) to central pulse pressure. SVR was computed as mean pressure/CO. Ea was computed as central end-systolic pressure/SV. RESULTS: During 10.3 years of follow-up, 91 definite HF events occurred. SVR (P = .74), TAC (P = .81), and Ea (P = .81) were not predictive of HF risk. RM was associated with increased HF risk, even after adjustment for other parameters of arterial load, various confounders, and markers of subclinical atherosclerosis (standardized hazard ratio [HR] 1.49, 95% confidence interval [CI] 1.18-1.88; P = .001). Pb was also associated with an increased risk of HF after adjustment for Pf (standardized HR 1.43, 95% CI 1.17-1.75; P = .001). CONCLUSIONS: RM is an important independent predictor of HF risk, whereas TAC, SVR, and Ea are not. Our findings support the importance of the systolic LV loading sequence on HF risk, independently from subclinical atherosclerosis.


Asunto(s)
Aterosclerosis/etnología , Aterosclerosis/fisiopatología , Etnicidad , Insuficiencia Cardíaca/epidemiología , Insuficiencia Cardíaca/fisiopatología , Población Blanca , Anciano , Anciano de 80 o más Años , Aterosclerosis/complicaciones , Presión Sanguínea/fisiología , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Modelos de Riesgos Proporcionales , Volumen Sistólico/fisiología , Resistencia Vascular/fisiología
6.
Curr Heart Fail Rep ; 13(2): 86-91, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26879390

RESUMEN

Heart transplantation is one of the most definitive therapies for end-stage heart failure. The therapy is unfortunately marred by the devastating complications of cardiac allograft vasculopathy (CAV). Non-invasive screening and assessment for CAV has been greatly limited by both low sensitivity and poor correlation with adverse outcomes. As such, invasive imaging with coronary angiography has emerged as the gold standard for detection of CAV. Although conventional coronary angiography serves well for larger lesions, the modality has been significantly enhanced with adjunct imaging to visualize the intimal hyperplasia that is a hallmark of the disease process. These modalities include intravascular ultrasound (IVUS) and optical coherence tomography (OCT). In the following review, we summarize both the invasive and non-invasive assessments of CAV. We further conclude that the current evidence poorly supports the use of non-invasive testing for early CAV and that a transition should be considered to routine early angiography with adjunctive intravascular imaging.


Asunto(s)
Aloinjertos/irrigación sanguínea , Aloinjertos/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Trasplante de Corazón/efectos adversos , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/etiología , Humanos , Tomografía de Coherencia Óptica , Ultrasonografía Intervencional
7.
Catheter Cardiovasc Interv ; 86(2): 316-22, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-25546704

RESUMEN

BACKGROUND: Transcatheter aortic valve replacement (TAVR) with the balloon-expandable Sapien transcatheter heart valve improves survival compared to standard therapy in patients with severe aortic stenosis (AS) and is noninferior to surgical aortic valve replacement (AVR) in patients at high operative risk. Nonetheless, a significant proportion of patients may require pre-emptive or emergent support with cardiopulmonary bypass (CPB) and/or intra-aortic balloon pump (IABP) during TAVR due to pre-existing comorbid conditions or as a result of procedural complications. OBJECTIVES: We hypothesized that patients who required CPB or IABP would have increased periprocedural complications and reduced long-term survival. In addition, we sought to determine whether preprocedural variables could predict the need for CPB and IABP. METHODS: The study population included 2,525 patients in the PARTNER Trial (Cohort A and B) and the continuing access registry (CAR). Patients that received CPB or IABP were compared to patients that did not receive either, and then further divided into those that received support pre-TAVR and those that were placed on support emergently. RESULTS: One-hundred sixty-three patients (6.5%) were placed on CPB and/or IABP. The use of CPB or IABP was associated with higher 1 year mortality (49.1% vs. 21.6%, P < 0.001). In multivariable analysis, utilization of CPB or IABP was an independent predictor of 30 day (HR 6.95) and 1-year (HR 2.56) mortality. Although mortality was highest in emergent cases, mortality was also greater in planned CPB and IABP cases compared with non-CPB/IABP cases (53.3% and 40.3% vs. 21.6%, P < 0.001). CONCLUSIONS: These findings indicate that CPB and IABP use in TAVR portends a poor prognosis and its utilization, particularly in the setting of pre-emptive use, needs reconsideration.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica , Cateterismo Cardíaco/mortalidad , Puente Cardiopulmonar/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Contrapulsador Intraaórtico/mortalidad , Anciano , Anciano de 80 o más Años , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Puente Cardiopulmonar/efectos adversos , Distribución de Chi-Cuadrado , Comorbilidad , Femenino , Prótesis Valvulares Cardíacas , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Contrapulsador Intraaórtico/efectos adversos , Estimación de Kaplan-Meier , Masculino , Análisis Multivariante , Modelos de Riesgos Proporcionales , Diseño de Prótesis , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos
8.
JTCVS Open ; 10: 128-139, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36004225

RESUMEN

Objective: To evaluate the flow dynamics of self-expanding and balloon-expandable transcatheter aortic valves pertaining to turbulence and pressure recovery. Transcatheter aortic valves are characterized by different designs that have different valve performance and outcomes. Methods: Assessment of transcatheter aortic valves was performed using self-expanding devices (26-mm Evolut [Medtronic], 23-mm Allegra [New Valve Technologies], and small Acurate neo [Boston Scientific]) and a balloon-expandable device (23-mm Sapien 3 [Edwards Lifesciences]). Particle image velocimetry assessed the flow downstream. A Millar catheter was used for pressure recovery calculation. Velocity, Reynolds shear stresses, viscous shear stress, and pressure gradients were calculated. Results: The maximal velocity at peak systole obtained with the Evolut R, Sapien 3, Acurate neo, and Allegra was 2.12 ± 0.19 m/sec, 2.41 ± 0.06 m/sec, 2.99 ± 0.10 m/sec, and 2.45 ± 0.08 m/sec, respectively (P < .001). Leaflet oscillations with the flow were clear with the Evolut R and Acurate neo. The Allegra shows the minimal range of Reynolds shear stress magnitudes (up to 320 Pa), and Sapien 3 the maximal (up to 650 Pa). The Evolut had the smallest viscous shear stress magnitude range (up to 3.5 Pa), and the Sapien 3 the largest (up to 6.2 Pa). The largest pressure drop at the vena contracta occurred with the Acurate neo transcatheter aortic valve with a pressure gradient of 13.96 ± 1.35 mm Hg. In the recovery zone, the smallest pressure gradient was obtained with the Allegra (3.32 ± 0.94 mm Hg). Conclusions: Flow dynamics downstream of different transcatheter aortic valves vary significantly depending on the valve type, despite not having a general trend depending on whether or not valves are self-expanding or balloon-expandable. Deployment design did not have an influence on flow dynamics.

9.
Vasc Med ; 16(5): 391-404, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22003003

RESUMEN

Personalized medicine refers to the application of an individual's biological fingerprint - the comprehensive dataset of unique biological information - to optimize medical care. While the principle itself is straightforward, its implementation remains challenging. Advances in pharmacogenomics as well as functional assays of vascular biology now permit improved characterization of an individual's response to medical therapy for vascular disease. This review describes novel strategies designed to permit tailoring of four major pharmacotherapeutic drug classes within vascular medicine: antiplatelet therapy, antihypertensive therapy, lipid-lowering therapy, and antithrombotic therapy. Translation to routine clinical practice awaits the results of ongoing randomized clinical trials comparing personalized approaches with standard of care management.


Asunto(s)
Enfermedades Cardiovasculares/tratamiento farmacológico , Medicina de Precisión/métodos , Antihipertensivos/uso terapéutico , Enfermedades Cardiovasculares/genética , Fibrinolíticos/uso terapéutico , Técnicas de Genotipaje , Humanos , Hipolipemiantes/uso terapéutico , Inhibidores de Agregación Plaquetaria/uso terapéutico
10.
Trends Cardiovasc Med ; 31(7): 427-432, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-33022385

RESUMEN

Despite ongoing advances in the treatment of heart failure, overall symptom burden remains high. Underlying the primary symptom of dyspnea are often elevations in left atrial pressures, which occur across the spectrum of heart failure subgroups. Current therapies do not directly address improvements in left atrial pressures; however, passive left atrial decompression may offer a new avenue to treat heart failure. New technologies are currently being evaluated in clinical testing and may offer a novel therapeutic approach to heart failure.


Asunto(s)
Cateterismo Cardíaco , Insuficiencia Cardíaca , Presión Atrial , Cateterismo Cardíaco/efectos adversos , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Humanos , Volumen Sistólico
11.
J Thorac Cardiovasc Surg ; 162(4): 1075-1083.e1, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-32222410

RESUMEN

OBJECTIVE: In this study, a 2-dimensional (2D) index relying on preprocedural computed tomography (CT) data was developed to evaluate the risk of coronary obstruction during transcatheter aortic valve replacement (TAVR) procedures. METHODS: Anatomic measurements from pre-TAVR CT scans were collected in 28 patients among 600 who were flagged as high risk (defined as meeting coronary artery height, h, <14 mm and/or sinus of Valsalva diameter, SOVd, <30 mm) for coronary obstruction. A geometric model derived from these anatomic measurements was used to predict the post-TAVR native cusp apposition relative to the coronary ostium. The distance from the cusp to the coronary ostium, DLC2D, was measured from the geometric model and indexed with the coronary artery diameter, d, to yield a fractional obstruction measure, DLC2D/d. RESULTS: Twenty-three of 28 high-risk patients successfully underwent TAVR without coronary obstruction, of whom 1 had coronary obstruction and 4 were deemed non-TAVR candidates. DLC2D/d differed significantly between the 2 groups (P < .0018), but neither h nor SOVd did (P > .32). The optimal sensitivity and specificity for DLC2D/d were 85% and occurred at a cutoff of 0.45. The optimal sensitivity and specificity of h and SOVd in this high-risk group were only 60% and 40%, respectively, for cutoffs of h = 10 mm and SOVd = 30.5 mm. CONCLUSIONS: The 2D geometric model derived in this study shows promise for identifying patients with low-lying coronary ostium and/or small SOVd that may be safely treated with TAVR. DLC2D/d is more predictive of obstruction or poor TAVR candidacy compared with h and SOVd.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Oclusión Coronaria/diagnóstico por imagen , Vasos Coronarios , Complicaciones Intraoperatorias/prevención & control , Cuidados Preoperatorios/métodos , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Angiografía por Tomografía Computarizada/métodos , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Vasos Coronarios/cirugía , Femenino , Humanos , Complicaciones Intraoperatorias/etiología , Masculino , Modelos Anatómicos , Modelación Específica para el Paciente , Ajuste de Riesgo/métodos , Tomografía Computarizada por Rayos X/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
12.
JACC Cardiovasc Interv ; 14(24): 2657-2666, 2021 12 27.
Artículo en Inglés | MEDLINE | ID: mdl-34838462

RESUMEN

OBJECTIVES: The aim of this study was to evaluate flow dynamics in the aortic sinus and the neosinus (NS) after transcatheter heart valve (THV) implantation in valve-in-valve (ViV). BACKGROUND: Leaflet thrombosis may occur on THVs and affect performance and durability. Differences in flow dynamics may affect the risk for leaflet thrombosis. METHODS: Hemodynamic assessment following THV implantation in a surgical aortic valve was performed in a left heart simulator under pulsatile physiological conditions. Assessment was performed using a 23-mm polymeric surgical aortic valve (not diseased) and multiple THV platforms, including self-expanding devices (26-mm Evolut, 23-mm Allegra, small ACURATE neo) and a balloon-expandable device (23-mm SAPIEN 3). Particle image velocimetry was performed to assess flow in the sinus and NS. Sinus and NS washout, shear stress, and velocity were calculated. RESULTS: Sinus and NS washout was fastest and approximately 1 cardiac cycle for each with the Evolut, ACURATE neo, and Allegra compared with the SAPIEN 3, with washout in 2 and 3 cardiac cycles, respectively. The Allegra showed the largest shear stress distribution in the sinus, followed by the SAPIEN 3. In the NS, all 4 valves showed equal likelihoods of occurrence of shear stress <1 Pa, but the Allegra showed the highest likelihoods of occurrence for shear stress >1 Pa. The velocities in the sinus and NS were 0.05, 0.078, 0.080, and 0.075 m/s for Evolut, SAPIEN 3, ACURATE neo, and Allegra ViV, respectively. CONCLUSIONS: Sinus and NS flow dynamics differ substantially among THVs after ViV. Self-expanding supra-annular valves seem to have faster washouts compared with an equivalent-size balloon-expandable THV.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Resultado del Tratamiento
13.
J Am Coll Cardiol ; 76(20): 2391-2411, 2020 11 17.
Artículo en Inglés | MEDLINE | ID: mdl-33190683

RESUMEN

Consensus regarding a reasonable strategy to manage cardiac conduction disturbances after transcatheter aortic valve replacement (TAVR) has been elusive. This is due to the absence of adequately powered, randomized controlled trials; the often transient nature of the conduction disturbances; evolving technologies; and the interplay of cardiology subspecialties involved. In the absence of high-quality trials, numerous practice styles have been developed, and prolonged observation, electrophysiological testing, and pre-emptive pacemaker implantation have been described. Although the 2013 European Society of Cardiology guidelines address pacing post-TAVR, they do not provide in-depth discussion of this topic. Furthermore, a summary and proposed strategy for this problem have not been published by cardiovascular societies in the United States, despite an interest in establishing best practices in TAVR, valvular heart disease, and cardiovascular implantable electrical devices. This document reviews existing data and experience regarding the management of conduction disturbances after TAVR and proposes an evidence-based expert consensus decision pathway for their management. Where evidence is lacking or insufficient, the recommendations herein are based on expert opinion.


Asunto(s)
Enfermedad de la Válvula Aórtica/cirugía , Trastorno del Sistema de Conducción Cardíaco/terapia , Complicaciones Posoperatorias/terapia , Reemplazo de la Válvula Aórtica Transcatéter , Técnicas de Apoyo para la Decisión , Humanos
14.
J Thorac Cardiovasc Surg ; 159(3): 829-838.e3, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31230808

RESUMEN

OBJECTIVE: In this study we aimed to evaluate risk of coronary obstruction during transcatheter aortic valve replacement and develop improved criteria based on computational modeling. METHODS: Patient specific 3-dimensional models were constructed and validated for 28 patients out of 600 patients who were flagged as high risk for coronary obstruction (defined as meeting coronary ostium height < 14 mm and/or sinus of Valsalva diameter [SOVd] < 30 mm). The models consisted finite element analysis to predict the post- transcatheter aortic valve replacement native cusp apposition relative to the coronary ostium and were validated in vitro. The distance from cusp to coronary ostium (DLC) was derived from the 3-dimensional models and indexed with the coronary artery diameter to yield a fractional obstruction measure (DLC/d). RESULTS: Twenty-two out of 28 high-risk patients successfully underwent transcatheter aortic valve replacement without coronary obstruction and 6 did not. DLC/d between the 2 groups was significantly different (P < .00078), whereas neither coronary ostium height nor SOVd were significantly different (P > .32). A cutoff of DLC/d < 0.7 was predictive with 100% sensitivity and 95.7% specificity. The optimal sensitivity and specificity of coronary ostium height and SOVd in this high-risk group was only 60% and 40%, respectively, for cutoff coronary ostium height of 10 mm and SOVd of 30.5 mm. CONCLUSIONS: Three-dimensional modeling has the potential to enable more patients to be safely treated with transcatheter aortic valve replacement who have a low-lying coronary ostium or small SOVd. DLC/d is more predictive of obstruction than coronary ostium height and SOVd.


Asunto(s)
Válvula Aórtica/cirugía , Estenosis Coronaria/etiología , Técnicas de Apoyo para la Decisión , Modelos Cardiovasculares , Modelación Específica para el Paciente , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Femenino , Prótesis Valvulares Cardíacas , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Diseño de Prótesis , Reproducibilidad de los Resultados , Medición de Riesgo , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento
15.
J Biomech ; 89: 115-118, 2019 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-31000346

RESUMEN

Coronary obstruction is a life threatening complication during and post-transcatheter aortic valve replacement (TAVR). The objective of this preliminary work is to investigate the mechanisms underlying coronary obstruction in a patient after TAVR, in whom coronary obstruction was confirmed in addition to highlighting the importance of pre-procedural planning. The aortic root of an 80-year old male patient with coronary obstruction during TAVR-where a 29 mm SAPIEN 3 was deployed-was segmented from Computed Tomography scans and 3D-printed with compliant material. Flow and pressure data were acquired in this 3D-printed model in-vitro using a pulse duplicator under physiological conditions for the cases: a 29 mm SAPIEN 3, a 26 mm SAPIEN 3 expanded with a 29 mm balloon, and a 31 mm Medtronic-CoreValve deployed annularly, supra and sub-annularly respectively. Only the CoreValve in sub-annular axial position and the 29 mm SAPIEN 3 yielded pressure gradients (PG) lower than 10 mmHg (6.76 ±â€¯0.52 and 5.72 ±â€¯0.13 mmHg respectively) while the 26 mm SAPIEN 3, CoreValve in normal and supra-annular positions yielded higher PGs (15.5 ±â€¯0.48, 12.2 ±â€¯0.15 and 10.8 ±â€¯0.24 mmHg respectively). 29 mm SAPIEN 3 implantation yielded an FFR value of 45.7 ±â€¯0.6%. However, 31 mm CoreValve in any of the three different annular positions yielded FFR values going from 89.6 ±â€¯1.1% in supra-annular position to 98.3 ±â€¯1.1% in sub-annular position. Implantation with a 26 mm SAPIEN 3 expanded with a 29 mm balloon also yielded an FFR of 92.1 ±â€¯1.2%. Coronary obstruction in this patient could have been prevented through usage of different valve types and/or through usage of a different combination of valve size-balloon sizes.


Asunto(s)
Enfermedad Coronaria/etiología , Enfermedad Coronaria/prevención & control , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano de 80 o más Años , Enfermedad Coronaria/diagnóstico por imagen , Fluoroscopía , Humanos , Masculino , Presión , Diseño de Prótesis , Tomografía Computarizada por Rayos X
16.
Curr Treat Options Cardiovasc Med ; 21(12): 86, 2019 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-31820126

RESUMEN

PURPOSE OF REVIEW: Functional mitral regurgitation (MR) in setting of cardiomyopathy causes significant morbidity and worsened survival. Surgical therapies have failed to demonstrate significant overall benefit for functional MR. More recently, major trials utilizing transcatheter therapies for functional MR have been completed and offer new avenues for intervention. This review evaluates and compares 2 major recent trials designed to test the benefit of edge-to-edge repair using the MitraClip system for severe functional MR. RECENT FINDINGS: The Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients with Functional Mitral Regurgitation (COAPT) and Percutaneous Repair with the MitraClip Device for Severe Functional/Secondary Mitral Regurgitation (MITRA-FR) trials were simultaneous trials evaluating the treatment of effect of MitraClip in the setting of severe functional mitral regurgitation. Results of the trials were quite different with COAPT demonstrating substantial clinical benefit including significantly improved survival compared with MITRA-FR in which no clinical benefit was derived. Key differences in the patient population between the COAPT and MITRA-FR trials help to explain the contrasting results between the 2 trials designed to test the same hypothesis. Patients in COAPT had higher severity of MR with less dilated ventricles compared with MITRA-FR. These results will help shape patient selection for who will most benefit from MitraClip therapy. Further transcather mitral valve therapies continue to evolve and will likely offer alternative therapies for MR as technology improves.

17.
Ann Biomed Eng ; 47(1): 75-84, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-30151733

RESUMEN

Leaflet thrombosis is a complication associated with transcatheter aortic valve (TAV) replacement (TAVR) correlated with sinus flow stasis. Sinus hemodynamics are important because they dictate shear stress and washout necessary to avoid stasis on TAV leaflets. Sinus flow is controlled by TAV axial deployment position but little is known regarding TAV axis misalignment effect. This study aims to elucidate TAV angular misalignment with respect to aortic root axis effect on sinus flow stasis potentially leading to leaflet thrombosis. Sinus hemodynamics were assessed in vitro using particle-image velocimetry in three different angular misalignments with respect to aorta axis: untilted, tilted away from the sinus and tilted towards sinus. A 26 mm Edwards SAPIEN3 was implanted in a 3D printed model of an anatomically realistic aortic root. TAV hemodynamics, sinus vortex tracking, leaflet shear stress probability density functions, and sinus blood time to washout were calculated. While pressure gradients differed insignificantly, blood velocity and vorticity decreased significantly in both tilted cases sinuses. Shear stress probability near the leaflet decreases with tilt indicating stasis. TAV tilted away from the sinus is the most unfavorable scenario with poor washout. TAV axial misalignment adds to factors list that could influence leaflet thrombosis risk through modifying sinus hemodynamics and washout.


Asunto(s)
Hemodinámica , Modelos Cardiovasculares , Impresión Tridimensional , Seno Aórtico , Reemplazo de la Válvula Aórtica Transcatéter , Femenino , Humanos , Masculino , Seno Aórtico/fisiopatología
18.
J Thorac Cardiovasc Surg ; 157(2): 540-549, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-29980299

RESUMEN

OBJECTIVE: The goal of this study is to evaluate how sinus flow patterns after transcatheter aortic valve replacement in realistic representative patient roots vary. Sinus flow can affect transcatheter aortic valve operation and likely leaflet thrombosis occurrence due to stasis and poor washout. How the interaction between transcatheter aortic valve and representative patient aortic roots affects sinus hemodynamics is important to establish for future individualization of transcatheter aortic valve replacement therapy. METHODS: Two representative patient aortic roots were selected, segmented and 3-dimensional printed followed by deployment of Medtronic CoreValve (Medtronic Inc, Irvine, Calif) and Edwards SAPIEN (Edwards Lifesciences, Irvine Calif) transcatheter aortic valves. Sinus hemodynamics were assessed in vitro using high spatio-temporal resolution particle-image-velocimetry. Detailed sinus vortex tracking, shear stress probability density functions, and sinus washout were evaluated and assessed as a function of valve type and representative patient morphology as independent case studies. RESULTS: Peak velocity in the sinus with SAPIEN valve was approximately 3 times higher than with CoreValve for both models (0.30 ± 0.02 m/s and 0.34 ± 0.041 m/s vs 0.13 ± 0.01 m/s and 0.10 ± 0.02 m/s) (P < .01). Between representative patient models, vorticity magnitudes were significantly different (75 ± 1.1 s-1, 77 ± 3.2 s-1, 109 ± 2.3 s-1, and 250 ± 4.1 s-1) (P < .01) regardless of valve type. Sinus blood washout characteristic as a function of cardiac cycles was strongly both patient related and valve specific. Fluid dynamics favored shear stresses and washout characteristics due to a smaller sinus and sinotubular junction, further amplified by the SAPIEN valve. CONCLUSIONS: Sinus flow dynamics are highly sensitive to aortic root characteristics and transcatheter aortic valve aortic root interaction. Differences in sinus-flow washout and stasis regions between representative patient models may be reflected in different risks of leaflet thrombosis or valve degeneration.


Asunto(s)
Válvula Aórtica/diagnóstico por imagen , Prótesis Valvulares Cardíacas , Hemodinámica/fisiología , Modelos Cardiovasculares , Modelación Específica para el Paciente , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Humanos , Trombosis/prevención & control , Tomografía Computarizada por Rayos X , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación
19.
JACC Cardiovasc Interv ; 12(9): 859-869, 2019 05 13.
Artículo en Inglés | MEDLINE | ID: mdl-31072507

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the safety and effectiveness of percutaneous mechanical thrombectomy using the FlowTriever System (Inari Medical, Irvine, California) in a prospective trial of patients with acute intermediate-risk pulmonary embolism (PE). BACKGROUND: Catheter-directed thrombolysis has been shown to improve right ventricular (RV) function in patients with PE. However, catheter-directed thrombolysis increases bleeding risk and many patients with PE have relative and absolute contraindications to thrombolysis. METHODS: Patients with symptomatic, computed tomography-documented PE and RV/left ventricular (LV) ratios ≥0.9 were eligible for enrollment. The primary effectiveness endpoint was core laboratory-assessed change in RV/LV ratio. The primary safety endpoint comprised device-related death, major bleeding, treatment-related clinical deterioration, pulmonary vascular injury, or cardiac injury within 48 h of thrombectomy. RESULTS: From April 2016 to October 2017, 106 patients were treated with the FlowTriever System at 18 U.S. sites. Two patients (1.9%) received adjunctive thrombolytics and were analyzed separately. Mean procedural time was 94 min; mean intensive care unit stay was 1.5 days. Forty-three patients (41.3%) did not require any intensive care unit stay. At 48 h post-procedure, average RV/LV ratio reduction was 0.38 (25.1%; p < 0.0001). Four patients (3.8%) experienced 6 major adverse events, with 1 patient (1.0%) experiencing major bleeding. One patient (1.0%) died, of undiagnosed breast cancer, through 30-day follow-up. CONCLUSIONS: Percutaneous mechanical thrombectomy with the FlowTriever System appears safe and effective in patients with acute intermediate-risk PE, with significant improvement in RV/LV ratio and minimal major bleeding. Potential advantages include immediate thrombus removal, absence of thrombolytic complications, and reduced need for post-procedural critical care.


Asunto(s)
Catéteres Cardíacos , Embolia Pulmonar/terapia , Trombectomía/instrumentación , Enfermedad Aguda , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Embolia Pulmonar/diagnóstico por imagen , Embolia Pulmonar/fisiopatología , Recuperación de la Función , Medición de Riesgo , Factores de Riesgo , Succión/instrumentación , Trombectomía/efectos adversos , Factores de Tiempo , Resultado del Tratamiento , Estados Unidos , Función Ventricular Izquierda , Función Ventricular Derecha
20.
Clin Cardiol ; 41(8): 1091-1096, 2018 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-29896847

RESUMEN

Chronic kidney disease (CKD) is associated with worse outcomes in high-surgical-risk patients undergoing transcatheter aortic valve replacement (TAVR). However, it is unclear whether this relationship is apparent in lower-surgical-risk patients. We sought to analyze existing literature to assess whether or not advanced CKD is associated with increased mortality or a greater incidence of adverse events (specifically major stroke, bleeding, and vascular complications). We searched PubMed and Embase (2008-2017) for relevant studies. Studies with <1 year follow-up and those not evaluating advanced CKD or outcomes post-TAVR were excluded. Our co-primary endpoints were the incidence of short-term mortality (defined as in-hospital or 30-day mortality) and long-term mortality (1 year). Our secondary endpoints included incidence of major stroke, life-threatening bleeding, and major vascular complications. Eleven observational studies with a total population of 10709 patients met the selection criteria. Among patients with CKD there was an increased risk of short- and long-term mortality in high-surgical-risk patients who underwent TAVR (hazard ratio [HR]: 1.51, 95% confidence interval [CI]: 1.22-1.88 and HR: 1.56, 95% CI: 1.38-1.77, respectively; P < 0.01). However, there was no association between CKD and mortality in low- to intermediate-risk patients (HR: 1.35, 95% CI: 0.98-1.84, P = 0.06 in short-term and HR: 1.08, 95% CI: 0.92-1.27, P = 0.34 in long-term). In low- to intermediate-risk TAVR patients, advanced CKD is not associated with increased mortality or poorer safety outcomes. These findings should be factored into the clinical decision-making process regarding TAVR candidacy.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Renal Crónica/complicaciones , Reemplazo de la Válvula Aórtica Transcatéter , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Salud Global , Humanos , Incidencia , Insuficiencia Renal Crónica/epidemiología , Factores de Riesgo , Índice de Severidad de la Enfermedad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA