Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 122
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Proteomics ; : e2300607, 2024 May 24.
Artículo en Inglés | MEDLINE | ID: mdl-38783781

RESUMEN

In this study, we sought to compare protein concentrations obtained from a high-throughput proteomics platform (Olink) on samples collected using capillary blood self-collection (with the Tasso+ device) versus standard venipuncture (control). Blood collection was performed on 20 volunteers, including one sample obtained via venipuncture and two via capillary blood using the Tasso+ device. Tasso+ samples were stored at 2°C-8°C for 24-hs (Tasso-24) or 48-h (Tasso-48) prior to processing to simulate shipping times from a study participant's home. Proteomics were analyzed using Olink (384 Inflammatory Panel). Tasso+ blood collection was successful in 37/40 attempts. Of 230 proteins included in our analysis, Pearson correlations (r) and mean coefficient of variation (CV) between Tasso-24 or Tasso-48 versus venipuncture were variable. In the Tasso-24 analysis, 34 proteins (14.8%) had both a correlation r > 0.5 and CV < 0.20. In the Tasso-48 analysis, 68 proteins (29.6%) had a correlation r > 0.5 and CV < 0.20. Combining the Tasso-24 and Tasso-48 analyses, 26 (11.3%) proteins met these thresholds. We concluded that protein concentrations from Tasso+ samples processed 24-48 h after collection demonstrated wide technical variability and variable correlation with a venipuncture gold-standard. Use of home capillary blood self-collection for large-scale proteomics should be limited to select proteins with good agreement with venipuncture.

2.
Am Heart J ; 268: 94-103, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38056546

RESUMEN

BACKGROUND: For patients with asymptomatic, severe aortic stenosis (AS) and preserved left ventricular ejection fraction, current guidelines recommend clinical surveillance every 6 to 12 months. To date, no randomized trials have examined whether an early intervention with transcatheter aortic valve replacement (TAVR) will improve outcomes among these patients. STUDY DESIGN AND OBJECTIVES: EARLY TAVR is a prospective, randomized, controlled, and multicenter trial, with an event-based design. Asymptomatic severe AS patients (n = 900) are randomized 1:1 to either clinical surveillance or TAVR with the Edwards SAPIEN 3/SAPIEN 3 Ultra transcatheter heart valve. Patients are stratified by whether they are able to perform a treadmill stress test. The primary end point is death, stroke, or unplanned cardiovascular hospitalization. Patients who are asymptomatic but have a positive stress test will be followed in a registry and undergo aortic valve replacement as per current guidelines. CONCLUSIONS: EARLY TAVR is the largest randomized trial to date assessing the role of early intervention among patients with asymptomatic severe AS compared to clinical surveillance and the first to study the role of TAVR. TRIAL REGISTRATION NUMBER: NCT03042104.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/epidemiología , Volumen Sistólico , Estudios Prospectivos , Factores de Riesgo , Resultado del Tratamiento , Función Ventricular Izquierda , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Índice de Severidad de la Enfermedad
3.
Eur Heart J ; 44(43): 4508-4532, 2023 11 14.
Artículo en Inglés | MEDLINE | ID: mdl-37793121

RESUMEN

Interest in the pathophysiology, etiology, management, and outcomes of patients with tricuspid regurgitation (TR) has grown in the wake of multiple natural history studies showing progressively worse outcomes associated with increasing TR severity, even after adjusting for multiple comorbidities. Historically, isolated tricuspid valve surgery has been associated with high in-hospital mortality rates, leading to the development of transcatheter treatment options. The aim of this first Tricuspid Valve Academic Research Consortium document is to standardize definitions of disease etiology and severity, as well as endpoints for trials that aim to address the gaps in our knowledge related to identification and management of patients with TR. Standardizing endpoints for trials should provide consistency and enable meaningful comparisons between clinical trials. A second Tricuspid Valve Academic Research Consortium document will focus on further defining trial endpoints and will discuss trial design options.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Insuficiencia de la Válvula Tricúspide/diagnóstico , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/etiología , Válvula Tricúspide/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Cardíaco/efectos adversos , Resultado del Tratamiento , Índice de Severidad de la Enfermedad
4.
Catheter Cardiovasc Interv ; 99(4): 1214-1224, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34936723

RESUMEN

OBJECTIVE: Our objective was to evaluate the impact of various blood pressures (BPs) on coronary perfusion and valvular hemodynamics following aortic valve replacement (AVR). BACKGROUND: Lower systolic and diastolic (SBP/DBP) pressures from the recommended optimal target range of SBP < 120-130 mmHg and DBP < 80 mmHg after AVR have been independently associated with increased cardiovascular and all-cause mortality. METHODS: The hemodynamic assessment of a 26 mm SAPIEN 3 transcatheter aortic valve (TAV), 29 mm Evolut R TAV, and 25 mm Magna Ease surgical aortic valve (SAV) was performed in a pulsed left heart simulator with varying SBP, DBP, and heart rate (HR) conditions (60 and 120 bpm) at 5 L/min cardiac output (CO). Average coronary flow (CF), effective orifice areas (EOAs), and valvulo-arterial impedance (Zva) were calculated. RESULTS: At HR of 60 bpm, at SBP < 120 mmHg and DBP < 60 mmHg, CF decreased below the physiological lower limit with several different valves. Zva and EOA were found to increase and decrease respectively with increasing SBP and DBP. The same results were found with an HR of 120 bpm. The trends of CF variation with BP were similar in all valves however the drop below the lower physiological CF limit was valve dependent. CONCLUSION: In a controlled in vitro system, with different aortic valve prostheses in place, CF decreased below the physiologic minimum when SBP and DBP were in the range targeted by blood pressure guidelines. Combined with recent observations from patients treated with AVR, these findings underscore the need for additional studies to identify the optimal BP in patients treated with AVR for AS.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/cirugía , Presión Sanguínea/fisiología , Hemodinámica , Humanos , Perfusión , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
5.
Arterioscler Thromb Vasc Biol ; 40(6): e153-e165, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32295422

RESUMEN

OBJECTIVE: Macrophages have been described in calcific aortic valve disease, but it is unclear if they promote or counteract calcification. We aimed to determine how macrophages are involved in calcification using the Notch1+/- model of calcific aortic valve disease. Approach and Results: Macrophages in wild-type and Notch1+/- murine aortic valves were characterized by flow cytometry. Macrophages in Notch1+/- aortic valves had increased expression of MHCII (major histocompatibility complex II). We then used bone marrow transplants to test if differences in Notch1+/- macrophages drive disease. Notch1+/- mice had increased valve thickness, macrophage infiltration, and proinflammatory macrophage maturation regardless of transplanted bone marrow genotype. In vitro approaches confirm that Notch1+/- aortic valve cells promote macrophage invasion as quantified by migration index and proinflammatory phenotypes as quantified by Ly6C and CCR2 positivity independent of macrophage genotype. Finally, we found that macrophage interaction with aortic valve cells promotes osteogenic, but not dystrophic, calcification and decreases abundance of the STAT3ß isoform. CONCLUSIONS: This study reveals that Notch1+/- aortic valve disease involves increased macrophage recruitment and maturation driven by altered aortic valve cell secretion, and that increased macrophage recruitment promotes osteogenic calcification and alters STAT3 splicing. Further investigation of STAT3 and macrophage-driven inflammation as therapeutic targets in calcific aortic valve disease is warranted.


Asunto(s)
Estenosis de la Válvula Aórtica/patología , Válvula Aórtica/patología , Calcinosis/patología , Macrófagos/fisiología , Factor de Transcripción STAT3/fisiología , Animales , Válvula Aórtica/inmunología , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/inmunología , Estenosis de la Válvula Aórtica/fisiopatología , Trasplante de Médula Ósea , Calcinosis/inmunología , Calcinosis/fisiopatología , Movimiento Celular , Óxidos S-Cíclicos/farmacología , Modelos Animales de Enfermedad , Expresión Génica , Genotipo , Humanos , Inflamación/patología , Macrófagos/química , Macrófagos/patología , Masculino , Ratones , Ratones Endogámicos C57BL , Ratones Noqueados , Osteogénesis , Receptor Notch1/análisis , Receptor Notch1/genética , Receptor Notch1/fisiología , Factor de Transcripción STAT3/antagonistas & inhibidores , Factor de Transcripción STAT3/genética
6.
BMC Cardiovasc Disord ; 21(1): 368, 2021 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-34340660

RESUMEN

BACKGROUND: Age-associated inflammation and immune system dysfunction have been implicated as mechanisms that increase risk for adverse long-term procedural outcomes in older adults. The purpose of this study was to investigate relationships between baseline inflammatory and innate antiviral gene expression and outcomes after transcatheter aortic valve replacement (TAVR) in older adults with severe aortic stenosis. METHODS: We performed a retrospective case-control study comparing pre-procedural pro-inflammatory and Type 1 interferon (IFN) gene expression in 48 controls with favorable outcomes (alive 1 year after TAVR with improved quality of life [QoL]) versus 48 individuals with unfavorable outcomes (dead by 1 year or alive at 1 year but with reduced QoL). Gene expression was evaluated in whole blood via (1) pre-defined composite scores of 19 inflammation-associated genes and 34 Type I IFN response genes, and (2) pro-inflammatory and antiviral transcription factor activity inferred from promotor based bioinformatics analyses of genes showing > 25% difference in average expression levels across groups. All analyses were adjusted for age, gender, body mass index, diabetes, immunosuppression, cardiovascular disease (CVD), and frailty. RESULTS: Relative to controls, those with unfavorable outcomes demonstrated higher expression of the pro-inflammatory gene composite prior to TAVR (p < 0.01) and bioinformatic indicators of elevated Nuclear Factor kB (p < 0.001) and Activator Protein 1 (p < 0.001) transcription factor activity, but no significant differences in Type I IFN-related gene expression. CONCLUSIONS: These results demonstrate that a pro-inflammatory state prior to TAVR, independent of CVD severity and frailty status, is associated with worse long-term procedural outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Mediadores de Inflamación/sangre , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Virus/inmunología , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/sangre , Estenosis de la Válvula Aórtica/genética , Estenosis de la Válvula Aórtica/mortalidad , Biomarcadores/sangre , Femenino , Regulación de la Expresión Génica , Interacciones Huésped-Patógeno , Humanos , Inmunidad Innata/genética , Masculino , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Transcriptoma , Resultado del Tratamiento , Estados Unidos
7.
Eur Heart J ; 41(8): 958-969, 2020 02 21.
Artículo en Inglés | MEDLINE | ID: mdl-31883339

RESUMEN

AIMS: B-type natriuretic peptide (BNP) is a cardiac neurohormone that is secreted in response to ventricular volume expansion and pressure overload. There are conflicting data regarding the association between BNP levels and outcomes after transcatheter aortic valve replacement (TAVR). We therefore sought to assess the association between baseline BNP and adverse outcomes in patients with symptomatic, severe aortic stenosis (AS), and left ventricular ejection fraction (LVEF) ≥50%, undergoing TAVR in the PARTNER 2 Trial and Registry. METHODS AND RESULTS: A total of 1782 patients were included in the analysis, and BNP was evaluated both as a continuous log-transformed value and by a priori categories: low (<50 pg/mL), normal (≥50 and <100 pg/mL), moderately elevated (≥100 and <400 pg/mL), or markedly elevated (≥400 pg/mL). Clinical outcomes from discharge to 2 years were compared between patients according to their baseline BNP level, using Kaplan-Meier event rates and multivariable Cox proportional hazards regression models. After adjustment, spline curves revealed a non-linear association between log-transformed BNP and all-cause and cardiovascular mortality in which both the lowest and highest values were associated with increased mortality. Two-year all-cause mortality rates for those with low (n = 86), normal (n = 202), moderately elevated (n = 885), and markedly elevated (n = 609) baseline BNP were 20.0%, 9.8%, 17.7%, and 26.1%, respectively. In adjusted models, compared to a normal baseline BNP, low [adjusted hazard ratio (HR) 2.6, 95% confidence interval (CI) 1.3-5.0, P-value 0.005], moderately elevated (adjusted HR 1.6, 95% CI 1.0-2.6, P-value 0.06), and markedly elevated (adjusted HR 2.1, 95% CI 1.3-3.5, P-value 0.003) BNP were associated with increased all-cause mortality, driven by cardiovascular mortality. CONCLUSIONS: In a large cohort of patients with severe symptomatic AS and preserved LVEF undergoing TAVR, all-cause and cardiovascular mortality rates at 2 years were higher in patients with low and markedly elevated BNP levels. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/ unique identifier #NCT01314313, #NCT02184442, #NCT03222128, and #NCT03222141.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Péptido Natriurético Encefálico , Sistema de Registros , Factores de Riesgo , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda
8.
Eur Heart J ; 41(8): 943-954, 2020 02 21.
Artículo en Inglés | MEDLINE | ID: mdl-31711153

RESUMEN

AIMS: Left ventricular pressure overload is associated with activation of the cardiac renin-angiotensin system, which may contribute to myocardial fibrosis and worse clinical outcomes. We sought to assess the association between treatment with angiotensin-converting enzyme inhibitors (ACEIs) or angiotensin II receptor blockers (ARBs) at baseline and clinical outcomes in patients with symptomatic, severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) in the PARTNER 2 trial and registries. METHODS AND RESULTS: A total of 3979 intermediate, high, or prohibitive risk patients who underwent TAVR in the PARTNER 2 trial and registries (excluding the valve in valve registry) were included in the study. Clinical outcomes at 2 years were compared according to baseline ACEI/ARB treatment status using Kaplan-Meier event rates and study-stratified multivariable Cox proportional hazards regression models. Sensitivity analysis was conducted using propensity score matching. Of 3979 patients who were included in the current analysis, 1736 (43.6%) were treated and 2243 (56.4%) were not treated with ACEI/ARB at baseline. Treatment with ACEI/ARB was associated with lower 2-year all-cause mortality (18.6% vs. 27.5%, P < 0.0001), cardiovascular mortality (12.3% vs. 17.9%, P < 0.0001), and non-cardiovascular mortality (7.2% vs. 11.7%, P < 0.0001). Angiotensin-converting enzyme inhibitor/ARB treatment at baseline remained independently associated with a lower hazard of 2-year all-cause and cardiovascular mortality after multivariable adjustment, and propensity score matching. CONCLUSION: In a large cohort of patients with severe symptomatic AS from the PARTNER 2 trial and registries, ACEI/ARB treatment at baseline was independently associated with a lower risk of 2-year all-cause and cardiovascular mortality.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Antagonistas de Receptores de Angiotensina/uso terapéutico , Inhibidores de la Enzima Convertidora de Angiotensina/uso terapéutico , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Humanos , Sistema de Registros , Sistema Renina-Angiotensina , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
10.
Eur Heart J ; 39(28): 2659-2667, 2018 07 21.
Artículo en Inglés | MEDLINE | ID: mdl-29741615

RESUMEN

Aims: In patients randomized to transcatheter or surgical aortic valve replacement (TAVR, SAVR), we sought to determine whether SAVR is associated with worsening right ventricular (RV) function and whether RV deterioration is associated with mortality. Methods and results: In 1376 patients from PARTNERIIA with paired baseline and 30-day core lab echocardiograms, worsening RV function was defined as decline by at least one grade from baseline to 30 days. Our primary outcome was all-cause mortality from 30 days to 2 years. Among 744 patients with TAVR, 62 (8.3%) had worsening RV function, compared with 156 of 632 patients with SAVR (24.7%) (P < 0.0001). In a multivariable model, SAVR [odds ratio (OR) 4.05, 95% confidence interval (CI) 2.55-6.44], a dilated RV (OR 2.38, 95% CI 1.37-4.14), and more than mild tricuspid regurgitation (TR) (OR 2.58, 95% CI 1.25-5.33) were associated with worsening RV function. There were 169 deaths, and patients with worsening RV function had higher all-cause mortality [hazard ratio (HR) 1.98, 95% CI 1.40-2.79]. This association remained robust after adjusting for clinical and echocardiographic variables. Among patients with worsening RV function, there was no mortality difference between TAVR and SAVR (HR 1.16, 95% CI 0.61-2.18). The development of moderate or severe RV dysfunction from baseline normal RV function conferred the worst prognosis (HR 2.87, 95% CI 1.40-5.89). Conclusion: After aortic valve replacement, worsening RV function is more common in patients with baseline RV dilation, more than mild TR, and in patients treated with SAVR. Worsening RV function and the magnitude of deterioration have important prognostic implications.


Asunto(s)
Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Complicaciones Posoperatorias/epidemiología , Disfunción Ventricular Derecha/epidemiología , Anciano de 80 o más Años , Progresión de la Enfermedad , Femenino , Humanos , Incidencia , Masculino , Complicaciones Posoperatorias/mortalidad , Pronóstico , Estudios Prospectivos , Reemplazo de la Válvula Aórtica Transcatéter , Disfunción Ventricular Derecha/mortalidad
11.
Circulation ; 135(20): 1956-1976, 2017 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-28507251

RESUMEN

Aortic stenosis is 1 of the most common heart valve diseases among adults. When symptoms develop, prognosis is poor, and current guidelines recommend prompt aortic valve replacement. Depending of the severity of the aortic stenosis and the presence of concomitant heart disease and medical comorbidities, stress testing represents a reasonable strategy to help better risk stratify asymptomatic patients. The present report provides a comprehensive review of the current available data on stress testing in aortic stenosis and subsequently summarizes its potential for guiding the optimal timing of aortic valve replacement.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico , Enfermedades Asintomáticas , Toma de Decisiones Clínicas/métodos , Prueba de Esfuerzo/métodos , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/terapia , Enfermedades Asintomáticas/terapia , Humanos
12.
Eur Heart J ; 38(45): 3351-3358, 2017 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-29020232

RESUMEN

AIMS: In patients with aortic stenosis (AS), risk stratification for aortic valve replacement (AVR) relies mainly on valve-related factors, symptoms and co-morbidities. We sought to evaluate the prognostic impact of a newly-defined staging classification characterizing the extent of extravalvular (extra-aortic valve) cardiac damage among patients with severe AS undergoing AVR. METHODS AND RESULTS: Patients with severe AS from the PARTNER 2 trials were pooled and classified according to the presence or absence of cardiac damage as detected by echocardiography prior to AVR: no extravalvular cardiac damage (Stage 0), left ventricular damage (Stage 1), left atrial or mitral valve damage (Stage 2), pulmonary vasculature or tricuspid valve damage (Stage 3), or right ventricular damage (Stage 4). One-year outcomes were compared using Kaplan-Meier techniques and multivariable Cox proportional hazards models were used to identify 1-year predictors of mortality. In 1661 patients with sufficient echocardiographic data to allow staging, 47 (2.8%) patients were classified as Stage 0, 212 (12.8%) as Stage 1, 844 (50.8%) as Stage 2, 413 (24.9%) as Stage 3, and 145 (8.7%) as Stage 4. One-year mortality was 4.4% in Stage 0, 9.2% in Stage 1, 14.4% in Stage 2, 21.3% in Stage 3, and 24.5% in Stage 4 (Ptrend < 0.0001). The extent of cardiac damage was independently associated with increased mortality after AVR (HR 1.46 per each increment in stage, 95% confidence interval 1.27-1.67, P < 0.0001). CONCLUSION: This newly described staging classification objectively characterizes the extent of cardiac damage associated with AS and has important prognostic implications for clinical outcomes after AVR.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/estadística & datos numéricos , Actividades Cotidianas , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/clasificación , Estenosis de la Válvula Aórtica/mortalidad , Ecocardiografía , Femenino , Humanos , Hipertensión Pulmonar/etiología , Hipertensión Pulmonar/mortalidad , Hipertensión Pulmonar/patología , Hipertrofia Ventricular Izquierda/etiología , Hipertrofia Ventricular Izquierda/mortalidad , Hipertrofia Ventricular Izquierda/patología , Masculino , Pronóstico , Estudios Retrospectivos , Medición de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Disfunción Ventricular Izquierda/etiología , Disfunción Ventricular Izquierda/mortalidad , Disfunción Ventricular Izquierda/patología , Disfunción Ventricular Derecha/etiología , Disfunción Ventricular Derecha/mortalidad , Disfunción Ventricular Derecha/patología
14.
J Card Surg ; 32(8): 454-461, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28833636

RESUMEN

BACKGROUND AND AIM: Left ventricular (LV) systolic strain has been shown to be an early marker of LV dysfunction in patients with severe aortic stenosis (AS) despite preserved ejection fraction (EF). Echocardiography has provided useful data on regional LV strain patterns, but is not as sensitive as magnetic resonance imaging (MRI). No prior studies have used MRI-based strain analysis to characterize regional three-dimensional strain in patients with severe AS. METHODS: Twelve patients with severe AS and preserved EF underwent MRI-based multiparametric strain analysis. Circumferential and longitudinal strain values were calculated at individual points throughout the LV and analyzed in 12 discrete regions. Strain values were compared to a database of normal controls. RESULTS: Compared to control patients, circumferential strain in AS patients was significantly reduced at the base (P = 0.002), mid (P = 0.042), and inferior walls (P < 0.001). Longitudinal strain was significantly reduced at the base (P < 0.001), mid (P < 0.001), anterior (P < 0.001), and septal (P < 0.001) walls. Among patients with AS, there was heterogeneity in the location and severity of abnormalities in circumferential and longitudinal strains despite the presence of a preserved EF and lack of prior myocardial infarction. CONCLUSIONS: LV systolic strain is significantly impaired in patients with AS and preserved EF compared to healthy volunteers. Abnormalities in circumferential and longitudinal strains were heterogeneously distributed across the LV of patients with AS, allowing us to identify sentinel regions that may reflect the earliest signs of developing LV dysfunction.


Asunto(s)
Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/fisiopatología , Volumen Sistólico , Disfunción Ventricular Izquierda/diagnóstico por imagen , Disfunción Ventricular Izquierda/etiología , Anciano , Ecocardiografía , Femenino , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Índice de Severidad de la Enfermedad , Sístole
15.
J Card Fail ; 21(11): 868-76, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-26164215

RESUMEN

OBJECTIVE: The aim of this work was to characterize the clinical response and identify predictors of clinical stabilization after intra-aortic balloon counterpulsation (IABP) support in patients with chronic systolic heart failure in cardiogenic shock before implantation of a left ventricular assist device (LVAD). BACKGROUND: Limited data exist regarding the clinical response to IABP in patients with chronic heart failure in cardiogenic shock. METHODS: We identified 54 patients supported with IABP before LVAD implantation. Criteria for clinical decompensation after IABP insertion and before LVAD included the need for more advanced temporary support, initiation of mechanical ventilation or dialysis, increase in vasopressors/inotropes, refractory ventricular arrhythmias, or worsening acidosis. The absence of these indicated stabilization. RESULTS: Clinical decompensation after IABP occurred in 23 patients (43%). Both patients who decompensated and those who stabilized had similar hemodynamic improvements after IABP support, but patients who decompensated required more vasopressors/inotropes. Clinical decompensation after IABP was associated with worse outcomes after LVAD implantation, including a 3-fold longer intensive care unit stay and 5-fold longer time on mechanical ventilation (P < .01 for both). Although baseline characteristics were similar between groups, right and left ventricular cardiac power indexes (cardiac power index = cardiac index × mean arterial pressure/451) identified patients who were likely to stabilize (area under the receiver operating characteristic curve = 0.82). CONCLUSIONS: Among patients with chronic systolic heart failure who develop cardiogenic shock, more than one-half of patients stabilized with IABP support as a bridge to LVAD. Baseline measures of right and left ventricular cardiac power, reflecting work performed for a given flow and pressure, may allow clinicians to identify patients with sufficient contractile reserve who will be likely to stabilize with an IABP versus those who may need more aggressive ventricular support.


Asunto(s)
Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/cirugía , Mortalidad Hospitalaria/tendencias , Contrapulsador Intraaórtico/métodos , Choque Cardiogénico/mortalidad , Choque Cardiogénico/cirugía , Anciano , Causas de Muerte , Enfermedad Crónica , Estudios de Cohortes , Progresión de la Enfermedad , Femenino , Estudios de Seguimiento , Insuficiencia Cardíaca/diagnóstico por imagen , Corazón Auxiliar , Hemodinámica/fisiología , Humanos , Contrapulsador Intraaórtico/efectos adversos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Cuidados Preoperatorios/métodos , Curva ROC , Estudios Retrospectivos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Choque Cardiogénico/diagnóstico , Ultrasonografía
16.
Circ Res ; 113(2): 223-37, 2013 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-23833296

RESUMEN

Calcific aortic stenosis is a progressive disease with no effective medical therapy that ultimately requires aortic valve replacement (AVR) for severe valve obstruction. Echocardiography is the primary diagnostic approach to define valve anatomy, measure aortic stenosis severity, and evaluate the left ventricular response to chronic pressure overload. In asymptomatic patients, markers of disease progression include the degree of leaflet calcification, hemodynamic severity of stenosis, adverse left ventricular remodeling, reduced left ventricular longitudinal strain, myocardial fibrosis, and pulmonary hypertension. The onset of symptoms portends a predictably high mortality rate unless AVR is performed. In symptomatic patients, AVR improves symptoms, improves survival, and, in patients with left ventricular dysfunction, improves systolic function. Poor outcomes after AVR are associated with low-flow low-gradient aortic stenosis, severe ventricular fibrosis, oxygen-dependent lung disease, frailty, advanced renal dysfunction, and a high comorbidity score. However, in most patients with severe symptoms, AVR is lifesaving. Bioprosthetic valves are recommended for patients aged >65 years. Transcatheter AVR is now available for patients with severe comorbidities, is recommended in patients who are deemed inoperable, and is a reasonable alternative to surgical AVR in high-risk patients.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Calcinosis/terapia , Cardiomiopatías/terapia , Animales , Estenosis de la Válvula Aórtica/diagnóstico , Calcinosis/diagnóstico , Cardiomiopatías/diagnóstico , Manejo de la Enfermedad , Humanos
17.
Catheter Cardiovasc Interv ; 94(1): 3-26, 2019 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-31002751
18.
Ann Biomed Eng ; 52(4): 888-897, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38157105

RESUMEN

Coexisting hypertension and aortic stenosis are common. Some studies showed that elevated blood pressures may be associated with progression of calcific aortic valve disease (CAVD) while others showed no correlation. Flow dynamics in the sinuses of Valsalva are considered key factors in the progression of CAVD. While the relationship between hemodynamics and CAVD is not yet fully understood, it has been demonstrated that they are tightly correlated. This study aims to investigate the effect of changing systolic and diastolic blood pressures (SBP and DBP, respectively) on sinus hemodynamics in relation to potential initiation or progression of CAVD after aortic valve replacement (AVR). Evolut R, SAPIEN 3 and Magna valves were deployed in an aortic root under pulsatile conditions. Using particle image velocimetry, the hemodynamics in the sinus were assessed. The velocity, vorticity, circulation ( Γ ) and shear stress were calculated. This study shows that under elevated SBP and DBP, velocity, vorticity, and shear stress nearby the leaflets increased. Additionally, larger fluctuations of Γ and area under the curve throughout the cardiac cycle were observed. Elevated blood pressures are associated with higher velocity, vorticity, and shear stress near the leaflets which may initiate or accelerate pro-calcific changes in the prosthetic leaflets leading to bioprosthetic valve degeneration.


Asunto(s)
Enfermedad de la Válvula Aórtica , Estenosis de la Válvula Aórtica , Válvula Aórtica/patología , Calcinosis , Humanos , Presión Sanguínea , Válvula Aórtica/cirugía , Hemodinámica
19.
PLoS One ; 19(5): e0302378, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38771808

RESUMEN

BACKGROUND: Guidelines recommend shared decision making when choosing treatment for severe aortic stenosis but implementation has lagged. We assessed the feasibility and impact of a novel decision aid for severe aortic stenosis at point-of-care. METHODS: This prospective multi-site pilot cohort study included adults with severe aortic stenosis and their clinicians. Patients were referred by their heart team when scheduled to discuss treatment options. Outcomes included shared decision-making processes, communication quality, decision-making confidence, decisional conflict, knowledge, stage of decision making, decision quality, and perceptions of the tool. Patients were assessed at baseline (T0), after using the intervention (T1), and after the clinical encounter (T2); clinicians were assessed at T2. Before the encounter, patients reviewed the intervention, Aortic Valve Improved Treatment Approaches (AVITA), an interactive, online decision aid. AVITA presents options, frames decisions, clarifies patient goals and values, and generates a summary to use with clinicians during the encounter. RESULTS: 30 patients (9 women [30.0%]; mean [SD] age 70.4 years [11.0]) and 14 clinicians (4 women [28.6%], 7 cardiothoracic surgeons [50%]) comprised 28 clinical encounters Most patients [85.7%] and clinicians [84.6%] endorsed AVITA. Patients reported AVITA easy to use [89.3%] and helped them choose treatment [95.5%]. Clinicians reported the AVITA summary helped them understand their patients' values [80.8%] and make values-aligned recommendations [61.5%]. Patient knowledge significantly improved at T1 and T2 (p = 0.004). Decisional conflict, decision-making stage, and decision quality improved at T2 (p = 0.0001, 0.0005, and 0.083, respectively). Most patients [60%] changed treatment preference between T0 and T2. Initial treatment preferences were associated with low knowledge, high decisional conflict, and poor decision quality; final preferences were associated with high knowledge, low conflict, and high quality. CONCLUSIONS: AVITA was endorsed by patients and clinicians, easy to use, improved shared decision-making quality and helped patients and clinicians arrive at a treatment that reflected patients' values. TRIAL REGISTRATION: Trial ID: NCT04755426, Clinicaltrials.gov/ct2/show/NCT04755426.


Asunto(s)
Estenosis de la Válvula Aórtica , Toma de Decisiones Conjunta , Técnicas de Apoyo para la Decisión , Estudios de Factibilidad , Prioridad del Paciente , Humanos , Estenosis de la Válvula Aórtica/terapia , Estenosis de la Válvula Aórtica/cirugía , Femenino , Masculino , Proyectos Piloto , Anciano , Persona de Mediana Edad , Estudios Prospectivos , Anciano de 80 o más Años , Participación del Paciente , Médicos/psicología , Relaciones Médico-Paciente , Toma de Decisiones
20.
Circ Cardiovasc Interv ; 17(2): e013298, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38235547

RESUMEN

BACKGROUND: Frailty associates with worse outcomes after transcatheter aortic valve replacement (TAVR). Sarcopenia underlies frailty, but the association between a comprehensive assessment of sarcopenia-muscle mass, strength, and performance-and outcomes after TAVR has not been examined. METHODS: From a multicenter prospective registry of patients with symptomatic severe aortic stenosis undergoing TAVR, 445 who had a preprocedure computed tomography and clinical assessment of frailty were included. Cross-sectional muscle (psoas and paraspinal) areas were measured on computed tomography and indexed to height. Gait speed and handgrip strength were obtained, and patients were dichotomized into fast versus slow; strong versus weak; and normal versus low muscle mass. As measures of body composition, cross-sectional fat (subcutaneous and visceral) was measured and indexed to height. RESULTS: The frequency of patients who were slow, weak, and had low muscle mass was 56%, 59%, and 42%, respectively. Among the 3 components of sarcopenia, only slower gait speed (muscle performance) was independently associated with increased post-TAVR mortality (adjusted hazard ratio, 1.12 per 0.1 m/s decrease [95% CI, 1.04-1.21]; P=0.004; adjusted hazard ratio, 1.38 per 1 SD decrease [95% CI, 1.11-1.72]; P=0.004). Meeting multiple sarcopenia criteria was not associated with higher mortality risk than fewer. Lower indexed visceral fat area (adjusted hazard ratio, 1.48 per 1 SD decrease [95% CI, 1.15-1.89]; P=0.002) was associated with mortality but indexed subcutaneous fat was not. Death occurred in 169 (38%) patients. CONCLUSIONS: Among patients with symptomatic severe aortic stenosis and comprehensive sarcopenia and body composition phenotyping, gait speed was the only sarcopenia measure associated with post-TAVR mortality. Lower visceral fat was also associated with increased risk pointing to an obesity paradox also observed in other patient populations. These findings reinforce the clinical utility of gait speed as a measure of risk and a potential target for adjunctive interventions alongside TAVR to optimize clinical outcomes.


Asunto(s)
Estenosis de la Válvula Aórtica , Fragilidad , Sarcopenia , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Sarcopenia/diagnóstico por imagen , Sarcopenia/complicaciones , Fragilidad/diagnóstico , Fragilidad/complicaciones , Resultado del Tratamiento , Fuerza de la Mano , Estudios Transversales , Medición de Riesgo , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Composición Corporal , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA