Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 68
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Build Environ ; 229: 109920, 2023 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-36569517

RESUMEN

Many respiratory diseases, including COVID-19, can be spread by aerosols expelled by infected people when they cough, talk, sing, or exhale. Exposure to these aerosols indoors can be reduced by portable air filtration units (air cleaners). Homemade or Do-It-Yourself (DIY) air filtration units are a popular alternative to commercially produced devices, but performance data is limited. Our study used a speaker-audience model to examine the efficacy of two popular types of DIY air filtration units, the Corsi-Rosenthal cube and a modified Ford air filtration unit, in reducing exposure to simulated respiratory aerosols within a mock classroom. Experiments were conducted using four breathing simulators at different locations in the room, one acting as the respiratory aerosol source and three as recipients. Optical particle spectrometers monitored simulated respiratory aerosol particles (0.3-3 µm) as they dispersed throughout the room. Using two DIY cubes (in the front and back of the room) increased the air change rate as much as 12.4 over room ventilation, depending on filter thickness and fan airflow. Using multiple linear regression, each unit increase of air change reduced exposure by 10%. Increasing the number of filters, filter thickness, and fan airflow significantly enhanced the air change rate, which resulted in exposure reductions of up to 73%. Our results show DIY air filtration units can be an effective means of reducing aerosol exposure. However, they also show performance of DIY units can vary considerably depending upon their design, construction, and positioning, and users should be mindful of these limitations.

2.
Indoor Air ; 32(2): e12987, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-35225389

RESUMEN

To limit community spread of SARS-CoV-2, CDC recommends universal masking indoors, maintaining 1.8 m of physical distancing, adequate ventilation, and avoiding crowded indoor spaces. Several studies have examined the independent influence of each control strategy in mitigating transmission in isolation, yet controls are often implemented concomitantly within an indoor environment. To address the influence of physical distancing, universal masking, and ventilation on very fine respiratory droplets and aerosol particle exposure, a simulator that coughed and exhaled aerosols (the source) and a second breathing simulator (the recipient) were placed in an exposure chamber. When controlling for the other two mitigation strategies, universal masking with 3-ply cotton masks reduced exposure to 0.3-3 µm coughed and exhaled aerosol particles by >77% compared to unmasked tests, whereas physical distancing (0.9 or 1.8 m) significantly changed exposure to cough but not exhaled aerosols. The effectiveness of ventilation depended upon the respiratory activity, that is, coughing or breathing, as well as the duration of exposure time. Our results demonstrate that a layered mitigation strategy approach of administrative and engineering controls can reduce personal inhalation exposure to potentially infectious very fine respiratory droplets and aerosol particles within an indoor environment.


Asunto(s)
Contaminación del Aire Interior , COVID-19 , Máscaras , Distanciamiento Físico , Ventilación , Contaminación del Aire Interior/prevención & control , COVID-19/prevención & control , Humanos , Aerosoles y Gotitas Respiratorias , SARS-CoV-2
3.
Clin Infect Dis ; 73(7): e1790-e1794, 2021 10 05.
Artículo en Inglés | MEDLINE | ID: mdl-33506256

RESUMEN

BACKGROUND: Previous research has shown that rooms of patients with coronavirus disease 2019 (COVID-19) present the potential for healthcare-associated transmission through aerosols containing severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2). However, data on the presence of these aerosols outside of patient rooms are limited. We investigated whether virus-containing aerosols were present in nursing stations and patient room hallways in a referral center with critically ill COVID-19 patients. METHODS: Eight National Institute for Occupational Safety and Health BC 251 2-stage cyclone samplers were set up throughout 6 units, including nursing stations and visitor corridors in intensive care units and general medical units, for 6 h each sampling period. Samplers were placed on tripods which held 2 samplers positioned 102 cm and 152 cm above the floor. Units were sampled for 3 days. Extracted samples underwent reverse transcription polymerase chain reaction for selected gene regions of the SARS-CoV-2 virus nucleocapsid and the housekeeping gene human RNase P as an internal control. RESULTS: The units sampled varied in the number of laboratory-confirmed COVID-19 patients present on the days of sampling. Some of the units included patient rooms under negative pressure, while most were maintained at a neutral pressure. Of 528 aerosol samples collected, none were positive for SARS-CoV-2 RNA by the estimated limit of detection of 8 viral copies/m3 of air. CONCLUSIONS: Aerosolized SARS-CoV-2 outside of patient rooms was undetectable. While healthcare personnel should avoid unmasked close contact with each other, these findings may provide reassurance for the use of alternatives to tight-fitting respirators in areas outside of patient rooms during the current pandemic.


Asunto(s)
COVID-19 , SARS-CoV-2 , Enfermedad Crítica , Humanos , ARN Viral/genética , Derivación y Consulta , Estados Unidos
4.
MMWR Morb Mortal Wkly Rep ; 70(7): 254-257, 2021 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-33600386

RESUMEN

Universal masking is one of the prevention strategies recommended by CDC to slow the spread of SARS-CoV-2, the virus that causes coronavirus disease 2019 (COVID-19) (1). As of February 1, 2021, 38 states and the District of Columbia had universal masking mandates. Mask wearing has also been mandated by executive order for federal property* as well as on domestic and international transportation conveyances.† Masks substantially reduce exhaled respiratory droplets and aerosols from infected wearers and reduce exposure of uninfected wearers to these particles. Cloth masks§ and medical procedure masks¶ fit more loosely than do respirators (e.g., N95 facepieces). The effectiveness of cloth and medical procedure masks can be improved by ensuring that they are well fitted to the contours of the face to prevent leakage of air around the masks' edges. During January 2021, CDC conducted experimental simulations using pliable elastomeric source and receiver headforms to assess the extent to which two modifications to medical procedure masks, 1) wearing a cloth mask over a medical procedure mask (double masking) and 2) knotting the ear loops of a medical procedure mask where they attach to the mask's edges and then tucking in and flattening the extra material close to the face (knotted and tucked masks), could improve the fit of these masks and reduce the receiver's exposure to an aerosol of simulated respiratory droplet particles of the size considered most important for transmitting SARS-CoV-2. The receiver's exposure was maximally reduced (>95%) when the source and receiver were fitted with modified medical procedure masks. These laboratory-based experiments highlight the importance of good fit to optimize mask performance. Until vaccine-induced population immunity is achieved, universal masking is a highly effective means to slow the spread of SARS-CoV-2** when combined with other protective measures, such as physical distancing, avoiding crowds and poorly ventilated indoor spaces, and good hand hygiene. Innovative efforts to improve the fit of cloth and medical procedure masks to enhance their performance merit attention.


Asunto(s)
COVID-19/prevención & control , Máscaras/normas , COVID-19/epidemiología , COVID-19/transmisión , Centers for Disease Control and Prevention, U.S. , Humanos , Máscaras/estadística & datos numéricos , Estados Unidos/epidemiología
5.
MMWR Morb Mortal Wkly Rep ; 70(27): 972-976, 2021 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-34237047

RESUMEN

SARS-CoV-2, the virus that causes COVID-19, can be spread by exposure to droplets and aerosols of respiratory fluids that are released by infected persons when they cough, sing, talk, or exhale. To reduce indoor transmission of SARS-CoV-2 between persons, CDC recommends measures including physical distancing, universal masking (the use of face masks in public places by everyone who is not fully vaccinated), and increased room ventilation (1). Ventilation systems can be supplemented with portable high efficiency particulate air (HEPA) cleaners* to reduce the number of infectious particles in the air and provide enhanced protection from transmission between persons (2); two recent reports found that HEPA air cleaners in classrooms could reduce overall aerosol particle concentrations by ≥80% within 30 minutes (3,4). To investigate the effectiveness of portable HEPA air cleaners and universal masking at reducing exposure to exhaled aerosol particles, the investigation team used respiratory simulators to mimic a person with COVID-19 and other, uninfected persons in a conference room. The addition of two HEPA air cleaners that met the Environmental Protection Agency (EPA)-recommended clean air delivery rate (CADR) (5) reduced overall exposure to simulated exhaled aerosol particles by up to 65% without universal masking. Without the HEPA air cleaners, universal masking reduced the combined mean aerosol concentration by 72%. The combination of the two HEPA air cleaners and universal masking reduced overall exposure by up to 90%. The HEPA air cleaners were most effective when they were close to the aerosol source. These findings suggest that portable HEPA air cleaners can reduce exposure to SARS-CoV-2 aerosols in indoor environments, with greater reductions in exposure occurring when used in combination with universal masking.


Asunto(s)
Aire Acondicionado/instrumentación , Filtros de Aire , Contaminación del Aire Interior/prevención & control , Máscaras , SARS-CoV-2 , Aerosoles , Diseño de Equipo , Humanos , Estados Unidos
6.
Proc Natl Acad Sci U S A ; 115(10): E2386-E2392, 2018 03 06.
Artículo en Inglés | MEDLINE | ID: mdl-29463703

RESUMEN

Epidemics and pandemics of influenza are characterized by rapid global spread mediated by non-mutually exclusive transmission modes. The relative significance between contact, droplet, and airborne transmission is yet to be defined, a knowledge gap for implementing evidence-based infection control measures. We devised a transmission chamber that separates virus-laden particles by size and determined the particle sizes mediating transmission of influenza among ferrets through the air. Ferret-to-ferret transmission was mediated by airborne particles larger than 1.5 µm, consistent with the quantity and size of virus-laden particles released by the donors. Onward transmission by donors was most efficient before fever onset and may continue for 5 days after inoculation. Multiple virus gene segments enhanced the transmissibility of a swine influenza virus among ferrets by increasing the release of virus-laden particles into the air. We provide direct experimental evidence of influenza transmission via droplets and fine droplet nuclei, albeit at different efficiency.


Asunto(s)
Aire/análisis , Subtipo H1N1 del Virus de la Influenza A/fisiología , Gripe Humana/transmisión , Gripe Humana/virología , Microbiología del Aire , Animales , Hurones , Humanos , Subtipo H1N1 del Virus de la Influenza A/química , Subtipo H1N1 del Virus de la Influenza A/genética , Masculino , Replicación Viral
7.
J Occup Environ Hyg ; 18(8): 409-422, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34161193

RESUMEN

Face masks reduce the expulsion of respiratory aerosols produced during coughs and exhalations ("source control"). Factors such as the directions in which people are facing (orientation) and separation distance also affect aerosol dispersion. However, it is not clear how the combined effects of masking, orientation, and distance affect the exposure of individuals to respiratory aerosols in indoor spaces. We placed a respiratory aerosol simulator ("source") and a breathing simulator ("recipient") in a 3 m × 3 m chamber and measured aerosol concentrations for different combinations of masking, orientation, and separation distance. When the simulators were front-to-front during coughing, masks reduced the 15-min mean aerosol concentration at the recipient by 92% at 0.9 and 1.8 m separation. When the simulators were side-by-side, masks reduced the concentration by 81% at 0.9 m and 78% at 1.8 m. During breathing, masks reduced the aerosol concentration by 66% when front-to-front and 76% when side-by-side at 0.9 m. Similar results were seen at 1.8 m. When the simulators were unmasked, changing the orientations from front-to-front to side-by-side reduced the cough aerosol concentration by 59% at 0.9 m and 60% at 1.8 m. When both simulators were masked, changing the orientations did not significantly change the concentration at either distance during coughing or breathing. Increasing the distance between the simulators from 0.9 m to 1.8 m during coughing reduced the aerosol concentration by 25% when no masks were worn but had little effect when both simulators were masked. During breathing, when neither simulator was masked, increasing the separation reduced the concentration by 13%, which approached significance, while the change was not significant when both source and recipient were masked. Our results show that universal masking reduces exposure to respiratory aerosol particles regardless of the orientation and separation distance between the source and recipient.


Asunto(s)
Tos , Espiración , Aerosoles , Tos/prevención & control , Humanos , Máscaras , Respiración
8.
Am J Obstet Gynecol ; 221(6): 644.e1-644.e5, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31201807

RESUMEN

OBJECTIVE: The objective of the study was to describe the characteristics and outcomes of patients with antenatal diagnosis of vasa previa and evaluate the predictive factors of resolution in a contemporary large, multicenter data set. STUDY DESIGN: This was a retrospective multicenter cohort study of all antenatally diagnosed cases of vasa previa, identified via ultrasound and electronic medical record, between January 2011 and July 2018 in 5 US centers. Records were abstracted to obtain variables at diagnosis, throughout pregnancy, and outcomes, including maternal and neonatal variables. Data were reported as median [range] or n (percentage). Descriptive statistics, receiver-operating characteristics, and logistic regression analysis were used as appropriate. RESULTS: One hundred thirty-six cases of vasa previa were identified in 5 centers during the study period, 19 (14%) of which resolved spontaneously at median estimated gestational age of 27 weeks [19-34]. All subjects with unresolved vasa previa underwent cesarean delivery at a median estimated gestational age of 34 weeks [27-39] with the median estimated blood loss of 800 mL [250-2000]. Rates for vaginal bleeding, preterm labor, premature rupture of membrane, and need for blood product transfusion were not different between the resolved and unresolved group (P = NS). The odds ratio for resolution in those with the estimated gestational age of less than 24 weeks at the time of diagnosis was 7.9 (95% confidence interval, 2.1-29.4) after adjustment for confounding variables. CONCLUSION: Our data suggest that outcomes in antenatally diagnosed cases of vasa previa are excellent. Furthermore, our data report a higher chance of resolution when the condition is diagnosed before 24 weeks of gestation.


Asunto(s)
Transfusión de Componentes Sanguíneos/estadística & datos numéricos , Cesárea/métodos , Rotura Prematura de Membranas Fetales/epidemiología , Trabajo de Parto Prematuro/epidemiología , Remisión Espontánea , Hemorragia Uterina/epidemiología , Vasa Previa/epidemiología , Adolescente , Adulto , Pérdida de Sangre Quirúrgica , Estudios de Cohortes , Femenino , Edad Gestacional , Humanos , Modelos Logísticos , Embarazo , Pronóstico , Curva ROC , Estudios Retrospectivos , Ultrasonografía Prenatal , Estados Unidos/epidemiología , Vasa Previa/diagnóstico por imagen , Adulto Joven
9.
J Occup Environ Hyg ; 16(12): 804-816, 2019 12.
Artículo en Inglés | MEDLINE | ID: mdl-31638865

RESUMEN

The protection of emergency medical service (EMS) workers from airborne disease transmission is important during routine transport of patients with infectious respiratory illnesses and would be critical during a pandemic of a disease such as influenza. However, few studies have examined the effectiveness of ambulance ventilation systems at reducing EMS worker exposure to airborne particles (aerosols). In our study, a cough aerosol simulator mimicking a coughing patient with an infectious respiratory illness was placed on a patient cot in an ambulance. The concentration and dispersion of cough aerosol particles were measured for 15 min at locations corresponding to likely positions of an EMS worker treating the patient. Experiments were performed with the patient cot at an angle of 0° (horizontal), 30°, and 60°, and with the ambulance ventilation system set to 0, 5, and 12 air changes/hour (ACH). Our results showed that increasing the air change rate significantly reduced the airborne particle concentration (p < 0.001). Increasing the air change rate from 0 to 5 ACH reduced the mean aerosol concentration by 34% (SD = 19%) overall, while increasing it from 0 to 12 ACH reduced the concentration by 68% (SD = 9%). Changing the cot angle also affected the concentration (p < 0.001), but the effect was more modest, especially at 5 and 12 ACH. Contrary to our expectations, the aerosol concentrations at the different worker positions were not significantly different (p < 0.556). Flow visualization experiments showed that the ventilation system created a recirculation pattern which helped disperse the aerosol particles throughout the compartment, reducing the effectiveness of the system. Our findings indicate that the ambulance ventilation system reduced but did not eliminate worker exposure to infectious aerosol particles. Aerosol exposures were not significantly different at different locations within the compartment, including locations behind and beside the patient. Improved ventilation system designs with smoother and more unidirectional airflows could provide better worker protection.


Asunto(s)
Aerosoles/análisis , Ambulancias , Transmisión de Enfermedad Infecciosa de Paciente a Profesional/prevención & control , Exposición Profesional/prevención & control , Ventilación/métodos , Aire Acondicionado/métodos , Tos , Servicios Médicos de Urgencia , Humanos , Infecciones del Sistema Respiratorio/transmisión
10.
J Occup Environ Hyg ; 15(1): 1-12, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29059039

RESUMEN

Ambulances are frequently contaminated with infectious microorganisms shed by patients during transport that can be transferred to subsequent patients and emergency medical service workers. Manual decontamination is tedious and time-consuming, and persistent contamination is common even after cleaning. Ultraviolet germicidal irradiation (UVGI) has been proposed as a terminal disinfection method for ambulance patient compartments. However, no published studies have tested the use of UVGI in ambulances. The objectives of this study were to investigate the efficacy of a UVGI system in an ambulance patient compartment and to examine the impact of UVGI fixture position and the UV reflectivity of interior surfaces on the time required for disinfection. A UVGI fixture was placed in the front, middle, or back of an ambulance patient compartment, and the UV irradiance was measured at 49 locations. Aluminum sheets and UV-reflective paint were added to examine the effects of increasing surface reflectivity on disinfection time. Disinfection tests were conducted using Bacillus subtilis spores as a surrogate for pathogens. Our results showed that the UV irradiance varied considerably depending upon the surface location. For example, with the UVGI fixture in the back position and without the addition of UV-reflective surfaces, the most irradiated location received a dose of UVGI sufficient for disinfection in 16 s, but the least irradiated location required 15 hr. Because the overall time required to disinfect all of the interior surfaces is determined by the time required to disinfect the surfaces receiving the lowest irradiation levels, the patient compartment disinfection times for different UVGI configurations ranged from 16.5 hr to 59 min depending upon the UVGI fixture position and the interior surface reflectivity. These results indicate that UVGI systems can reduce microbial surface contamination in ambulance compartments, but the systems must be rigorously validated before deployment. Optimizing the UVGI fixture position and increasing the UV reflectivity of the interior surfaces can substantially improve the performance of a UVGI system and reduce the time required for disinfection.


Asunto(s)
Ambulancias , Bacillus subtilis/efectos de la radiación , Desinfección/métodos , Rayos Ultravioleta , Infección Hospitalaria/prevención & control , Desinfección/instrumentación , Pintura , Esporas Bacterianas/efectos de la radiación
11.
J Occup Environ Hyg ; 15(9): 664-675, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-30081757

RESUMEN

Increased understanding of influenza transmission is critical for pandemic planning and selecting appropriate controls for healthcare personnel safety and health. The goals of this pilot study were to assess environmental contamination in different areas and at two time periods in the influenza season and to determine the feasibility of using surgical mask contamination to evaluate potential exposure to influenza virus. Bioaerosol samples were collected over 12 days (two 6-day sessions) at 12 locations within a student health center using portable two-stage bioaerosol samplers operating 8 hr each day. Surface samples were collected each morning and afternoon from common high-contact non-porous hard surfaces from rooms and locations where bioaerosol samplers were located. Surgical masks worn by participants while in contact with patients with influenza-like illness were collected. A questionnaire administered to each of the 12 participants at the end of each workday and another at the end of each workweek assessed influenza-like illness symptoms, estimated the number of influenza-like illness patient contacts, hand hygiene, and surgical mask usage. All samples were analyzed using qPCR. Over the 12 days of the study, three of the 127 (2.4%) bioaerosol samples, 2 of 483 (0.41%) surface samples, and 0 of 54 surgical masks were positive for influenza virus. For the duration of contact that occurred with an influenza patient on any of the 12 days, nurse practitioners and physicians reported contacts with influenza-like illness patients >60 min, medical assistants reported 15-44 min, and administrative staff reported <30 min. Given the limited number of bioaerosol and surface samples positive for influenza virus in the bioaerosol and surface samples, the absence of influenza virus on the surgical masks provides inconclusive evidence for the potential to use surgical masks to assess exposure to influenza viruses. Further studies are needed to determine feasibility of this approach in assessing healthcare personnel exposures. Information learned in this study can inform future field studies on influenza transmission.


Asunto(s)
Personal de Salud , Gripe Humana/transmisión , Máscaras/virología , Aerosoles , Humanos , Transmisión de Enfermedad Infecciosa de Paciente a Profesional/prevención & control , Maryland/epidemiología , Exposición Profesional , Orthomyxoviridae/genética , Orthomyxoviridae/aislamiento & purificación , Proyectos Piloto , ARN Viral , Reacción en Cadena en Tiempo Real de la Polimerasa , Estudiantes , Encuestas y Cuestionarios , Lugar de Trabajo
12.
Inhal Toxicol ; 29(2): 75-81, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-28330428

RESUMEN

Moisture-damaged indoor environments are thought to increase the toxicity of indoor air particulate matter (PM), indicating that a toxicological assay could be used as a method for recognizing buildings with indoor air problems. We aimed to test if our approach of analyzing the toxicity of actively collected indoor air PM in vitro differentiates moisture-damaged from non-damaged school buildings. We collected active air samples with NIOSH Bioaerosol Cyclone Samplers from moisture-damaged (index) and non-damaged (reference) school buildings (4 + 4). The teachers and pupils of the schools were administered a symptom questionnaire. Five samples of two size fractions [Stage 1 (>1.9 µm) and Stage 2 (1-1.9 µm)] were collected from each school. Mouse RAW264.7 macrophages were exposed to the collected PM for 24 h and subsequently analyzed for changes in cell metabolic activity, production of nitric oxide (NO), tumor necrosis factor (TNF)-α and interleukin (IL)-6. The teachers working in the moisture-damaged schools reported respiratory symptoms such as cough (p = 0.01) and shortness of breath (p = 0.01) more often than teachers from reference schools. Toxicity of the PM sample as such did not differentiate index from reference building,s but the toxicity adjusted for the amount of the particles tended to be higher in moisture-damaged schools. Further development of the method will require identification of other confounding factors in addition to the necessity to adjust for differences in particle counts between samples.


Asunto(s)
Contaminación del Aire Interior/efectos adversos , Polvo , Humedad , Material Particulado/efectos adversos , Instituciones Académicas , Contaminación del Aire Interior/análisis , Animales , Monitoreo del Ambiente , Femenino , Estado de Salud , Humanos , Interleucina-6/metabolismo , Masculino , Ratones , Óxido Nítrico/metabolismo , Material Particulado/análisis , Células RAW 264.7 , Maestros , Estudiantes , Factor de Necrosis Tumoral alfa/metabolismo
15.
J Virol ; 89(19): 9939-51, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26202239

RESUMEN

UNLABELLED: Poultry exposure is a major risk factor for human H7N9 zoonotic infections, for which the mode of transmission remains unclear. We studied the transmission of genetically related poultry and human H7N9 influenza viruses differing by four amino acids, including the host determinant PB2 residue 627. A/Silkie chicken/HK/1772/2014 (SCk1772) and A/HK/3263/14 (HK3263) replicated to comparable titers in chickens, with superior oropharyngeal over cloacal shedding; both viruses transmitted efficiently among chickens via direct contact but inefficiently via the airborne route. Interspecies transmission via the airborne route was observed for ferrets exposed to the SCk1772- or HK3263-infected chickens, while low numbers of copies of influenza viral genome were detected in the air, predominantly at particle sizes larger than 4 µm. In ferrets, the human isolate HK3263 replicated to higher titers and transmitted more efficiently via direct contact than SCk1772. We monitored "intrahost" and "interhost" adaptive changes at PB2 residue 627 during infection and transmission of the Sck1772 that carried E627 and HK3263 that carried V/K/E polymorphism at 60%, 20%, and 20%, respectively. For SCk1772, positive selection for K627 over E627 was observed in ferrets during the chicken-to-ferret or ferret-to-ferret transmission. For HK3263 that contained V/K/E polymorphism, mixed V627 and E627 genotypes were transmitted among chickens while either V627 or K627 was transmitted to ferrets with a narrow transmission bottleneck. Overall, our results suggest direct contact as the main mode for H7N9 transmission and identify the PB2-V627 genotype with uncompromised fitness and transmissibility in both avian and mammalian species. IMPORTANCE: We studied the modes of H7N9 transmission, as this information is crucial for developing effective control measures for prevention. Using chicken (SCk1772) and human (HK3263) H7N9 isolates that differed by four amino acids, including the host determinant PB2 residue 627, we observed that both viruses transmitted efficiently among chickens via direct contact but inefficiently via the airborne route. Chicken-to-ferret transmission via the airborne route was observed, along with the detection of viral genome in the air at low copy numbers. In ferrets, HK3263 transmitted more efficiently than SCk1772 via direct contact. During the transmission of SCk1772 that contained E and HK3263 that contained V/K/E polymorphism at PB2 residue 627, positive selections of E627 and K627 were observed in chickens and ferrets, respectively. In addition, PB2-V627 was transmitted and stably maintained in both avian and mammalian species. Our results support applying intervention strategies that minimize direct and indirect contact at the poultry markets during epidemics.


Asunto(s)
Subtipo H7N9 del Virus de la Influenza A/genética , Gripe Aviar/transmisión , Gripe Aviar/virología , Infecciones por Orthomyxoviridae/veterinaria , Polimorfismo Genético , ARN Polimerasa Dependiente del ARN/genética , Proteínas Virales/genética , Zoonosis/transmisión , Zoonosis/virología , Microbiología del Aire , Animales , Pollos/virología , Hurones/virología , Genoma Viral , Interacciones Huésped-Patógeno/genética , Humanos , Subtipo H7N9 del Virus de la Influenza A/aislamiento & purificación , Subtipo H7N9 del Virus de la Influenza A/patogenicidad , Gripe Humana/transmisión , Gripe Humana/virología , Infecciones por Orthomyxoviridae/transmisión , Infecciones por Orthomyxoviridae/virología , Enfermedades de las Aves de Corral/transmisión , Enfermedades de las Aves de Corral/virología , ARN Viral/genética , ARN Viral/aislamiento & purificación , Especificidad de la Especie
16.
Inhal Toxicol ; 28(11): 500-7, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-27569522

RESUMEN

There is a need for toxicity tests capable of recognizing indoor environments with compromised air quality, especially in the context of moisture damage. One of the key issues is sampling, which should both provide meaningful material for analyses and fulfill requirements imposed by practitioners using toxicity tests for health risk assessment. We aimed to evaluate different existing methods of sampling indoor particulate matter (PM) to develop a suitable sampling strategy for a toxicological assay. During three sampling campaigns in moisture-damaged and non-damaged school buildings, we evaluated one passive and three active sampling methods: the Settled Dust Box (SDB), the Button Aerosol Sampler, the Harvard Impactor and the National Institute for Occupational Safety and Health (NIOSH) Bioaerosol Cyclone Sampler. Mouse RAW264.7 macrophages were exposed to particle suspensions and cell metabolic activity (CMA), production of nitric oxide (NO) and tumor necrosis factor (TNFα) were determined after 24 h of exposure. The repeatability of the toxicological analyses was very good for all tested sampler types. Variability within the schools was found to be high especially between different classrooms in the moisture-damaged school. Passively collected settled dust and PM collected actively with the NIOSH Sampler (Stage 1) caused a clear response in exposed cells. The results suggested the higher relative immunotoxicological activity of dust from the moisture-damaged school. The NIOSH Sampler is a promising candidate for the collection of size-fractionated PM to be used in toxicity testing. The applicability of such sampling strategy in grading moisture damage severity in buildings needs to be developed further in a larger cohort of buildings.


Asunto(s)
Contaminación del Aire Interior/análisis , Monitoreo del Ambiente/métodos , Material Particulado/análisis , Contaminación del Aire Interior/efectos adversos , Animales , Monitoreo del Ambiente/instrumentación , Ratones , Óxido Nítrico/metabolismo , Material Particulado/toxicidad , Células RAW 264.7 , Instituciones Académicas , Pruebas de Toxicidad/métodos , Factor de Necrosis Tumoral alfa/metabolismo
17.
J Ultrasound Med ; 35(1): 1-5, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26635256

RESUMEN

The aim of this study was to provide a comprehensive review of the current data surrounding an intrahepatic persistent right umbilical vein in the fetus, including associated anomalies and outcomes, and to assist practitioners in counseling and management of affected pregnancies. We performed a MEDLINE, Embase, Cochrane Central Register of Controlled Trials, and Northern Light database search for articles reporting outcomes on prenatally diagnosed cases of a persistent right umbilical vein. Each article was independently reviewed for eligibility by the investigators. Thereafter, the data were extracted and validated independently by 3 investigators. A total of 322 articles were retrieved, and 16 were included in this systematic review. The overall prevalence of an intrahepatic persistent right umbilical vein was found to be 212 per 166,548 (0.13%). Of the 240 cases of an intrahepatic persistent right umbilical vein identified, 183 (76.3%) were isolated. The remaining cases had a coexisting abnormality, including 19 (7.9%) cardiac, 9 (3.8%) central nervous system, 15 (6.3%) genitourinary, 3 (1.3%) genetic, and 17 (7%) placental/cord (predominantly a single umbilical artery). In summary, a persistent right umbilical vein is commonly an isolated finding but may be associated with a coexisting cardiac defect in 8% of cases. Therefore, consideration should be given to fetal echocardiography in cases of a persistent right umbilical vein.


Asunto(s)
Vena Porta/anomalías , Ultrasonografía/estadística & datos numéricos , Venas Umbilicales/anomalías , Venas Umbilicales/diagnóstico por imagen , Malformaciones Vasculares/diagnóstico por imagen , Malformaciones Vasculares/epidemiología , Femenino , Humanos , Masculino , Vena Porta/diagnóstico por imagen , Prevalencia , Factores de Riesgo
18.
Euro Surveill ; 21(35)2016 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-27608369

RESUMEN

Zoonotic infections by avian influenza viruses occur at the human-poultry interface, but the modes of transmission have not been fully investigated. We assessed the potential for airborne and fomite transmission at live poultry markets in Guangzhou city and in Hong Kong Special Administrative Region (SAR), China, during 2014 and 2015. Viral genome and infectious avian influenza A viruses of H5N6, H7N9, and H9N2 subtypes were detected predominantly from particles larger or equal to 1 µm in diameter in the air sampled with cyclone-based bioaerosol samplers at the live poultry markets in Guangzhou. Influenza A(H9N2) viruses were ubiquitously isolated every month during the study period from air and environmental swabs, and different lineages of H9N2 virus were isolated from markets where chickens and minor land-based poultry were sold. The use of de-feathering devices increased the quantity of virus-laden airborne particles while market closure reduced the amount of such particles. The results highlight the possibility of airborne transmission of avian influenza viruses among poultry or from poultry to humans within such settings. This may explain epidemiological observations in which some patients with H7N9 infection reported being in markets but no direct contact with live poultry or poultry stalls.


Asunto(s)
Pollos/virología , Coinfección/veterinaria , Subtipo H7N9 del Virus de la Influenza A/aislamiento & purificación , Subtipo H9N2 del Virus de la Influenza A/aislamiento & purificación , Gripe Aviar/virología , Enfermedades de las Aves de Corral/virología , Animales , China , Coinfección/virología , Comercio , Microbiología Ambiental , Genoma Viral , Hong Kong , Humanos , Subtipo H7N9 del Virus de la Influenza A/clasificación , Subtipo H7N9 del Virus de la Influenza A/genética , Subtipo H9N2 del Virus de la Influenza A/clasificación , Subtipo H9N2 del Virus de la Influenza A/genética , Gripe Humana/virología , Filogenia , Aves de Corral/virología , Zoonosis
19.
J Occup Environ Hyg ; 12(8): 509-17, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25806411

RESUMEN

The ability to disinfect and reuse disposable N95 filtering facepiece respirators (FFRs) may be needed during a pandemic of an infectious respiratory disease such as influenza. Ultraviolet germicidal irradiation (UVGI) is one possible method for respirator disinfection. However, UV radiation degrades polymers, which presents the possibility that UVGI exposure could degrade the ability of a disposable respirator to protect the worker. To study this, we exposed both sides of material coupons and respirator straps from four models of N95 FFRs to UVGI doses from 120-950 J/cm(2). We then tested the particle penetration, flow resistance, and bursting strengths of the individual respirator coupon layers, and the breaking strength of the respirator straps. We found that UVGI exposure led to a small increase in particle penetration (up to 1.25%) and had little effect on the flow resistance. UVGI exposure had a more pronounced effect on the strengths of the respirator materials. At the higher UVGI doses, the strength of the layers of respirator material was substantially reduced (in some cases, by >90%). The changes in the strengths of the respirator materials varied considerably among the different models of respirators. UVGI had less of an effect on the respirator straps; a dose of 2360 J/cm(2) reduced the breaking strength of the straps by 20-51%. Our results suggest that UVGI could be used to effectively disinfect disposable respirators for reuse, but the maximum number of disinfection cycles will be limited by the respirator model and the UVGI dose required to inactivate the pathogen.


Asunto(s)
Desinfección/métodos , Dispositivos de Protección Respiratoria , Rayos Ultravioleta , Equipo Reutilizado , Filtración/instrumentación , Transmisión de Enfermedad Infecciosa de Paciente a Profesional/prevención & control , Ensayo de Materiales/métodos
20.
J Occup Environ Hyg ; 12(2): 107-13, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25523206

RESUMEN

Patients with influenza release aerosol particles containing the virus into their environment. However, the importance of airborne transmission in the spread of influenza is unclear, in part because of a lack of information about the infectivity of the airborne virus. The purpose of this study was to determine the amount of viable influenza A virus that was expelled by patients in aerosol particles while coughing. Sixty-four symptomatic adult volunteer outpatients were asked to cough 6 times into a cough aerosol collection system. Seventeen of these participants tested positive for influenza A virus by viral plaque assay (VPA) with confirmation by viral replication assay (VRA). Viable influenza A virus was detected in the cough aerosol particles from 7 of these 17 test subjects (41%). Viable influenza A virus was found in the smallest particle size fraction (0.3 µm to 8 µm), with a mean of 142 plaque-forming units (SD 215) expelled during the 6 coughs in particles of this size. These results suggest that a significant proportion of patients with influenza A release small airborne particles containing viable virus into the environment. Although the amounts of influenza A detected in cough aerosol particles during our experiments were relatively low, larger quantities could be expelled by influenza patients during a pandemic when illnesses would be more severe. Our findings support the idea that airborne infectious particles could play an important role in the spread of influenza.


Asunto(s)
Aerosoles/análisis , Microbiología del Aire , Tos/virología , Virus de la Influenza A/aislamiento & purificación , Gripe Humana/transmisión , Adolescente , Adulto , Femenino , Humanos , Masculino , Tamaño de la Partícula , ARN Viral/análisis , ARN Viral/aislamiento & purificación , Ensayo de Placa Viral , Replicación Viral
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA