Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
J Clin Microbiol ; 61(1): e0033722, 2023 01 26.
Artículo en Inglés | MEDLINE | ID: mdl-36541768

RESUMEN

The classification of viruses remains relevant to several disciplines, including clinical virology. Since the original publication of this review in 2019, many known viruses have undergone taxonomic revisions, and several novel human and animal viruses have been described. Here, we provide an update to our previous reviews of taxonomic changes for disease-causing viruses of humans, covering changes that occurred between 2020 and 2022. As with previous editions, this update was informed by recent advances in virus taxonomy made by the International Committee on Taxonomy of Viruses; the changes and additions noted herein are not all-inclusive.


Asunto(s)
Virus , Humanos , Virus/clasificación
2.
J Clin Microbiol ; 60(9): e0050122, 2022 09 21.
Artículo en Inglés | MEDLINE | ID: mdl-35658526

RESUMEN

COVID-19 disease lies on a spectrum, ranging from completely asymptomatic to mild disease to severe and critical disease. Studies have shown that prolonged shedding or sporadic detection of SARS-CoV-2 RNA can occur long after symptom resolution. Adding to these clinical complexities is the demand for testing for SARS-CoV-2 at all stages of diseases, frequently driven by screening of asymptomatic persons, something that traditionally has not been performed for other viral respiratory diseases. This can lead to positive results from nucleic acid amplification tests (NAATs), such as RT-PCR, with late cycle threshold (CT) values near the test's limit of detection. In this commentary, we review unique attributes of COVID-19 and causes of NAAT late CT values. We provide interpretation considerations as well as strategies to aid in test interpretation.


Asunto(s)
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Prueba de COVID-19 , Humanos , Técnicas de Amplificación de Ácido Nucleico/métodos , ARN Viral/genética , SARS-CoV-2/genética
3.
J Clin Microbiol ; 59(2)2021 01 21.
Artículo en Inglés | MEDLINE | ID: mdl-32848040

RESUMEN

The classification of viruses is relevant to a number of scientific and clinical disciplines, including the practice of diagnostic virology. Here, we provide an update to our previous review of taxonomic changes for disease-causing viruses in humans and vertebrate animals, covering changes between 2018 and 2020. Recent advances in virus taxonomy structure by the International Committee on Taxonomy of Viruses inform this update.


Asunto(s)
Virus , Animales , Humanos , Virus/genética
4.
J Clin Microbiol ; 59(3)2021 02 18.
Artículo en Inglés | MEDLINE | ID: mdl-33298613

RESUMEN

With the approach of respiratory virus season in the Northern Hemisphere, clinical microbiology and public health laboratories will need rapid diagnostic assays to distinguish severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) from influenza virus and respiratory syncytial virus (RSV) infections for diagnosis and surveillance. In this study, the clinical performance of the Xpert Xpress SARS-CoV-2/Flu/RSV test (Cepheid, Sunnyvale, CA, USA) for nasopharyngeal swab specimens was evaluated in four centers: Johns Hopkins Medical Microbiology Laboratory, Northwell Health Laboratories, NYC Public Health Laboratory, and Los Angeles County/University of Southern California (LAC+USC) Medical Center. A total of 319 nasopharyngeal swab specimens, positive for SARS-CoV-2 (n = 75), influenza A virus (n = 65), influenza B virus (n = 50), or RSV (n = 38) or negative (n = 91) by the standard-of-care nucleic acid amplification tests at each site, were tested using the Cepheid panel test. The overall positive percent agreement for the SARS-CoV-2 target was 98.7% (n = 74/75), and the negative agreement was 100% (n = 91), with all other analytes showing 100% total agreement (n = 153). Standard-of-care tests to which the Cepheid panel was compared included the Cepheid Xpert Xpress SARS-CoV-2, Cepheid Xpert Xpress Flu/RSV, GenMark ePlex respiratory panel, BioFire respiratory panel 2.1 and v1.7, DiaSorin Simplexa COVID-19 Direct, and Hologic Panther Fusion SARS-CoV-2 assays. The Xpert Xpress SARS-CoV-2/Flu/RSV test showed high sensitivity and accuracy for all analytes included in the test. This test will provide a valuable clinical diagnostic and public health solution for detecting and differentiating SARS-CoV-2, influenza A and B virus, and RSV infections during the current respiratory virus season.


Asunto(s)
COVID-19/diagnóstico , Gripe Humana/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Humanos , Nasofaringe , SARS-CoV-2 , Sensibilidad y Especificidad
5.
Clin Infect Dis ; 71(Suppl 1): S43-S51, 2020 06 24.
Artículo en Inglés | MEDLINE | ID: mdl-32578864

RESUMEN

We reviewed relevant syphilis diagnostic literature to address the question "What diagnostic considerations should be taken into account when screening for syphilis using the traditional or reverse algorithm?" Improved laboratory diagnosis of syphilis is an important element of the effort to reduce syphilis rates. Screening for syphilis is performed using either a nontreponemal or treponemal test (part of the traditional or reverse algorithm, respectively). Both syphilis algorithms are used by laboratories. However, there are limited data on the performance and cost-effectiveness of the algorithms. An expert panel generated "key questions" in the laboratory diagnosis of syphilis. This paper pertains to the key factors that should be considered when deciding whether to screen for syphilis using either the traditional or the reverse algorithm. A systematic literature review was performed, and tables of evidence were created to address this question.


Asunto(s)
Sífilis , Algoritmos , Análisis Costo-Beneficio , Humanos , Tamizaje Masivo , Sensibilidad y Especificidad , Sífilis/diagnóstico , Serodiagnóstico de la Sífilis , Treponema pallidum
6.
J Clin Microbiol ; 58(11)2020 10 21.
Artículo en Inglés | MEDLINE | ID: mdl-32843530

RESUMEN

Serologic methods are an important part of a clinical laboratory's portfolio of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) tests and are essential to the broader response to coronavirus infectious disease 2019 (COVID-19), including epidemiological studies and vaccine development. There are currently a number of commercial SARS-CoV-2 antibody tests with emergency use authorization (EUA) from the U.S. Food and Drug Administration. In this issue of the Journal of Clinical Microbiology, H. E. Prince, T. S. Givens, M. Lapé-Nixon, N. J. Clarke, et al. (J Clin Microbiol 58:e01742-20, https://doi.org/10.1128/JCM.01742-20, 2020) report the results of their evaluation of the agreement of 4 high-throughput EUA tests for SARS-CoV-2 IgG: Abbott Architect, DiaSorin Liaison, Euroimmun, and Ortho Vitros. They showed excellent agreement between the tests and rare false-positive reactivity for all tests.


Asunto(s)
Infecciones por Coronavirus , Pandemias , Neumonía Viral , Coronavirus Relacionado al Síndrome Respiratorio Agudo Severo , Anticuerpos Antivirales , Betacoronavirus , COVID-19 , Prueba de COVID-19 , Técnicas de Laboratorio Clínico , Infecciones por Coronavirus/diagnóstico , Humanos , Inmunoensayo , Inmunoglobulina G , Nucleocápside , SARS-CoV-2 , Pruebas Serológicas , Glicoproteína de la Espiga del Coronavirus
7.
J Clin Microbiol ; 58(8)2020 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-32366669

RESUMEN

Nucleic acid amplification tests (NAATs) are the primary means of identifying acute infections caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Accurate and fast test results may permit more efficient use of protective and isolation resources and allow rapid therapeutic interventions. We evaluated the analytical and clinical performance characteristics of the Xpert Xpress SARS-CoV-2 (Xpert) test, a rapid, automated molecular test for SARS-CoV-2. Analytical sensitivity and specificity/interference were assessed with infectious SARS-CoV-2; other infectious coronavirus species, including SARS-CoV; and 85 nasopharyngeal swab specimens positive for other respiratory viruses, including endemic human coronaviruses (hCoVs). Clinical performance was assessed using 483 remnant upper- and lower-respiratory-tract specimens previously analyzed by standard-of-care (SOC) NAATs. The limit of detection of the Xpert test was 0.01 PFU/ml. Other hCoVs, including Middle East respiratory syndrome coronavirus, were not detected by the Xpert test. SARS-CoV, a closely related species in the subgenus Sarbecovirus, was detected by a broad-range target (E) but was distinguished from SARS-CoV-2 (SARS-CoV-2-specific N2 target). Compared to SOC NAATs, the positive agreement of the Xpert test was 219/220 (99.5%), and the negative agreement was 250/261 (95.8%). A third tie-breaker NAAT resolved all but three of the discordant results in favor the Xpert test. The Xpert test provided sensitive and accurate detection of SARS-CoV-2 in a variety of upper- and lower-respiratory-tract specimens. The high sensitivity and short time to results of approximately 45 min may impact patient management.


Asunto(s)
Betacoronavirus/aislamiento & purificación , Técnicas de Laboratorio Clínico/métodos , Infecciones por Coronavirus/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Neumonía Viral/diagnóstico , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Automatización de Laboratorios/métodos , Betacoronavirus/genética , COVID-19 , Prueba de COVID-19 , Niño , Preescolar , Infecciones por Coronavirus/virología , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Persona de Mediana Edad , Nasofaringe/virología , Pandemias , Neumonía Viral/virología , SARS-CoV-2 , Sensibilidad y Especificidad , Adulto Joven
8.
J Clin Microbiol ; 57(2)2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30305385

RESUMEN

The classification of viruses provides the structure necessary to appreciate their biological diversity. Herein, we provide an update to our previous review of changes in viral taxonomy, covering changes between 2016 and 2018.


Asunto(s)
Clasificación/métodos , Virosis/veterinaria , Virosis/virología , Virus/clasificación , Animales , Humanos , Virus/aislamiento & purificación
9.
J Clin Microbiol ; 57(4)2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30760532

RESUMEN

Surveillance of circulating microbial populations is critical for monitoring the performance of a molecular diagnostic test. In this study, we characterized 31 isolates of Streptococcus agalactiae (group B Streptococcus [GBS]) from several geographic locations in the United States and Ireland that contain deletions in or adjacent to the region of the chromosome that encodes the hemolysin gene cfb, the region targeted by the Xpert GBS and GBS LB assays. PCR-negative, culture-positive isolates were recognized during verification studies of the Xpert GBS assay in 12 laboratories between 2012 and 2018. Whole-genome sequencing of 15 GBS isolates from 11 laboratories revealed four unique deletions of chromosomal DNA ranging from 181 bp to 49 kb. Prospective surveillance studies demonstrated that the prevalence of GBS isolates containing deletions in the convenience sample was <1% in three geographic locations but 7% in a fourth location. Among the 15 isolates with chromosomal deletions, multiple pulsed-field gel electrophoresis types were identified, one of which appears to be broadly dispersed across the United States.


Asunto(s)
Genoma Bacteriano/genética , Técnicas de Diagnóstico Molecular/normas , Eliminación de Secuencia , Streptococcus agalactiae/genética , Proteínas Bacterianas/genética , Técnicas Bacteriológicas , Electroforesis en Gel de Campo Pulsado , Proteínas Hemolisinas/genética , Humanos , Irlanda/epidemiología , Tipificación de Secuencias Multilocus , Filogenia , Infecciones Estreptocócicas/epidemiología , Infecciones Estreptocócicas/microbiología , Streptococcus agalactiae/clasificación , Estados Unidos/epidemiología
10.
J Clin Microbiol ; 56(3)2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-29305539

RESUMEN

Rapid detection of group A Streptococcus (GAS) is an integral component of treatment decisions in the clinic, especially in the pediatric population. We prospectively collected 216 specimens from symptomatic, predominantly pediatric patients and evaluated the performance of the Alere i Strep A test (Alere i; Alere Inc., Scarborough, ME) and the BD Veritor system (BD Veritor; Becton, Dickinson and Company, Sparks, MD), with culture results being used as a comparator. Real-time PCR (RT-PCR) was performed as an arbiter in discordant cases. Comprehensive chart review was also done to determine the hypothetical impact of the results on antibiotic use. Alere i had a sensitivity and a specificity of 100% and 91.3%, respectively, and BD Veritor had a sensitivity and a specificity of 76.2% and 93.6%, respectively, when the results were compared to those of GAS culture. Further analysis of discordant results using RT-PCR revealed that while BD Veritor missed 13 confirmed positive cases, Alere i detected 100% (n = 13) of the same cases. Analysis of assay agreement showed that Alere i and BD Veritor had only moderate agreement (agreement = 0.888 [95% confidence interval {CI}, 0.838 to 0.927]; kappa index = 0.689 [95% CI, 0.91 to 0.974]). We also found both the underutilization and the overutilization of antibiotics based on the results of molecular testing. Overall, Alere i showed superior performance over BD Veritor in the detection of GAS pharyngitis and could potentially assist in better antibiotic utilization.


Asunto(s)
Pruebas Diagnósticas de Rutina/normas , Infecciones Estreptocócicas/diagnóstico , Streptococcus pyogenes/aislamiento & purificación , Antibacterianos/uso terapéutico , Humanos , Inmunoensayo/normas , Técnicas de Amplificación de Ácido Nucleico/normas , Faringe/microbiología , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Infecciones Estreptocócicas/tratamiento farmacológico
11.
J Clin Microbiol ; 55(11): 3236-3241, 2017 11.
Artículo en Inglés | MEDLINE | ID: mdl-28878003

RESUMEN

A syphilis diagnosis is often aided by the detection of treponemal and nontreponemal antibodies. Automated treponemal antibody detection systems enable high-volume clinical laboratories to perform syphilis screening at a faster pace with lower labor costs. The Lumipulse G TP-N chemiluminescent immunoassay is an automated system that qualitatively detects IgG and IgM antibodies against Treponema pallidum antigens in human serum and plasma. To assess performance characteristics and workflow efficiency, the Lumipulse G TP-N assay was compared to the Bioplex 2200 Syphilis IgG multiplex flow immunoassay. Among the 4,134 routine and HIV samples tested by the two automated assays, the percentage of agreement was excellent at 99.0% (95% confidence interval [CI], 98.6% to 99.2%; κ, 0.89), with the Lumipulse G TP-N having a shorter time to first and subsequent results. All specimens with reactive syphilis screening results were further tested by rapid plasma reagin (RPR) and Treponema pallidum particle agglutination (TP·PA) testing (n = 231). The results from the RPR-reactive samples (n = 82) showed complete concordance with the two automated assays, while the TP·PA assay displayed some discrepancies. The positive percent agreement (PPA) and negative percent agreement (NPA) between the TP·PA test and the Lumipulse G TP-N test were 98.9% and 77.3%, respectively. The Bioplex 2200 Syphilis IgG immunoassay displayed a similar PPA (100%) but a substantially lower NPA (15.9%). Patient chart reviews of discrepant results suggested that the Lumipulse G TP-N assay produced 27 fewer falsely reactive results and can reduce the amount of additional confirmatory RPR and TP·PA testing needed. The analogous performance characteristics of the two automated systems indicate that the Lumipulse G TP-N assay is suitable for high-throughput syphilis screening.


Asunto(s)
Anticuerpos Antibacterianos/sangre , Pruebas Diagnósticas de Rutina/métodos , Inmunoensayo/métodos , Mediciones Luminiscentes/métodos , Tamizaje Masivo/métodos , Sífilis/diagnóstico , Treponema pallidum/inmunología , Automatización de Laboratorios/métodos , Errores Diagnósticos , Humanos , Inmunoglobulina G/sangre , Inmunoglobulina M/sangre , Factores de Tiempo
12.
J Clin Microbiol ; 55(1): 48-52, 2017 01.
Artículo en Inglés | MEDLINE | ID: mdl-27795337

RESUMEN

Taxonomical classification of newly discovered viruses and reclassification of previously discovered viruses provide an important foundation for detailing biological differences of scientific and clinical interest. The development of molecular analytical methods has enabled finer levels and more precise levels of classification. Periodically, there is need to refresh the literature and common understanding of current taxonomic classification, which we attempt to do here in addressing changes in human and animal viruses of medical significance between 2012 and 2015.


Asunto(s)
Clasificación/métodos , Virosis/veterinaria , Virosis/virología , Virus/clasificación , Virus/aislamiento & purificación , Animales , Humanos
13.
J Clin Microbiol ; 55(10): 3028-3036, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28768729

RESUMEN

Currently, the laboratory diagnosis of Zika virus (ZIKV) infection is primarily through the detection of ZIKV RNA or antibodies against ZIKV proteins. The detection of viral RNA is highly sensitive and specific, but periods of viremia and viruria are brief, limiting the utility of ZIKV RNA assays. Instead, most ZIKV infections are diagnosed serologically, using an IgM antibody capture enzyme-linked immunosorbent assay (MAC-ELISA) for screening, followed by a confirmatory plaque reduction neutralization test (PRNT). Typical turnaround times vary, due to assay incubation periods and a lack of clinical laboratories performing these tests. Recently, a novel luciferase-ZIKV- and -dengue virus (DENV)-based serological assay, which considerably improves the turnaround times and throughput for ZIKV diagnosis, was described. Using the traditional PRNT as a reference method, we evaluated the performance characteristics of the reporter virus neutralization test (RVNT) with 258 clinical serum specimens. The ZIKV RVNT produced primary ZIKV screening and secondary confirmation results in 4 days, with 100% reproducibility. As a screening assay, the ZIKV RVNT displayed excellent diagnostic accuracy, sensitivity, and specificity of 98.2%, 100%, and 98.1%, respectively. As a confirmatory assay, the ZIKV RVNT titers displayed 93.1% agreement with the traditional ZIKV PRNT titers. Overall, the RVNT accurately and reliably detects neutralizing antibodies in patient serum specimens, with improved turnaround times, and can be used for the serological detection of ZIKV infections. Due to the homogeneous 96-well format, the RVNT has also significantly improved the assay throughput to allow testing of a large number of specimens in a single run.


Asunto(s)
Virus del Dengue/inmunología , Dengue/diagnóstico , Pruebas de Neutralización/métodos , Viremia/diagnóstico , Infección por el Virus Zika/diagnóstico , Virus Zika/inmunología , Animales , Anticuerpos Neutralizantes/inmunología , Anticuerpos Antivirales/sangre , Línea Celular , Chlorocebus aethiops , Dengue/virología , Ensayo de Inmunoadsorción Enzimática/métodos , Humanos , Inmunoglobulina M/sangre , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Células Vero , Viremia/virología , Infección por el Virus Zika/virología
14.
J Clin Microbiol ; 55(7): 2198-2203, 2017 07.
Artículo en Inglés | MEDLINE | ID: mdl-28468854

RESUMEN

The Zika virus (ZIKV) epidemic in the Americas poses a public health emergency that requires a swift response. Accurate and reliable ZIKV diagnostic tests serve as an important tool for limiting the spread of ZIKV infections. The Aptima Zika virus assay (Hologic, Marlborough, MA) performed on the automated Panther system is a rapid and high-throughput method for detecting ZIKV RNA using transcription-mediated amplification (TMA) technology. We evaluated the performance characteristics of the Aptima Zika virus assay on clinical serum and urine specimens (n = 124) from two different patient populations and samples spiked with ZIKV from three different lineages (n = 10). Compared to the real-time reverse transcription-PCR (rRT-PCR) reference method, the Aptima ZIKV assay detected ZIKV RNA with a diagnostic accuracy of 94.8% (95% confidence interval [CI], 89.4 to 97.6), a sensitivity of 94.7% (95% CI, 73.5 to 99.9), and a specificity of 94.8% (95% CI, 88.9 to 97.8). Similar results were obtained regardless of whether a serum or urine source was used. The limits of detection of the assay at a 95% detection probability were 11.5 genome copy equivalents (GCE)/ml (95% fiducial limits, 7.9 to 20.2) in serum and 17.9 GCE/ml (95% fiducial limits, 13.1 to 27.5) in urine. The Aptima Zika virus assay results were highly reproducible (99%), and no cross-reactivity was seen during the testing of a panel of 95 specimens with potentially interfering substances, such as clinically relevant bacteria, fungi, and viruses, including other flaviviruses. The excellent performance characteristics and the convenience of a fully automated testing system make the Aptima ZIKV assay an attractive choice for clinical laboratories detecting ZIKV RNA from serum and urine.


Asunto(s)
Técnicas de Diagnóstico Molecular/métodos , ARN Viral/sangre , ARN Viral/orina , Infección por el Virus Zika/diagnóstico , Virus Zika/aislamiento & purificación , Animales , Automatización de Laboratorios/métodos , Femenino , Humanos , Masculino , Embarazo , ARN Viral/genética , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Virus Zika/genética
16.
Sex Transm Dis ; 43(12): 737-740, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27835625

RESUMEN

BACKGROUND: Our reverse syphilis testing algorithm consists of a treponemal IgG multiplex flow immunoassay (MFI) followed by both rapid plasma reagin titer and the Treponema pallidum particle agglutination (TPPA) test on specimens with a reactive MFI result. We report here the impact of a modified reverse algorithm, in which the strength of signal of the MFI is used to avoid unnecessary TPPA testing. METHODS: The Bioplex syphilis IgG MFI was used as the syphilis screening assay, and specimens with equivocal (antibody index 0.9 or 1.0), or reactive (antibody index ≥ 1.1) results were further tested by rapid plasma reagin titer and TPPA test. We performed a retrospective, descriptive analysis of all specimens received for syphilis screening between January and May of 2014. A cost analysis was performed, taking into account labor and reagent expenses. RESULTS: In our diverse patient population consisting of high-risk incarcerated persons, low-risk obstetrical/gynecological patients and high-risk miscellaneous clinic and inpatients, 430 (65%) of 665 MFI-positive specimens had antibody indices of 8 or greater. Greater than 99% of these specimens were reactive by the TPPA test. Avoiding TPPA testing of specimens with an MFI antibody index ≥8 would save over US $4800 annually in laboratory costs. CONCLUSIONS: The TPPA testing is unnecessary on specimens with MFI antibody indices ≥8. This would substantially reduce the TPPA testing volume and also reduce laboratory expenses.


Asunto(s)
Anticuerpos Antibacterianos/inmunología , Sífilis/diagnóstico , Treponema pallidum/aislamiento & purificación , Pruebas de Aglutinación , Algoritmos , Femenino , Humanos , Inmunoensayo , Masculino , Estudios Retrospectivos , Sensibilidad y Especificidad , Sífilis/microbiología , Serodiagnóstico de la Sífilis/economía , Treponema pallidum/inmunología
17.
Clin Infect Dis ; 60(1): 1-9, 2015 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-25205769

RESUMEN

BACKGROUND: Sensitive diagnostic assays have increased the detection of viruses in asymptomatic individuals. The clinical significance of asymptomatic respiratory viral infection in infants is unknown. METHODS: High-throughput, quantitative polymerase chain reaction assays were used to detect 13 common respiratory viruses from nasopharyngeal specimens collected during 2028 visits from 362 infants followed from near birth up to 12 months of age. Specimens were collected at monthly interval (months 1-6 and month 9) and during upper respiratory tract infection (URTI) episodes. Subjects were followed closely for acute otitis media (AOM) development. RESULTS: Viruses were detected in 76% of 394 URTI specimens and 27% of asymptomatic monthly specimens. Rhinovirus was detected most often; multiple viruses were detected in 29% of the specimens. Generalized mixed-model analyses associated symptoms with increasing age and female sex; detection of respiratory syncytial virus (RSV), influenza, rhinovirus, metapneumovirus, and adenovirus was highly associated with symptoms. Increasing age was also associated with multiple virus detection. Overall, 403 asymptomatic viral infections in 237 infants were identified. Viral load was significantly higher in URTI specimens than asymptomatic specimens but did not differentiate cases of URTI with and without AOM complication. The rate of AOM complicating URTI was 27%; no AOM occurred following asymptomatic viral infections. AOM development was associated with increasing age and infection with RSV, rhinovirus, enterovirus, adenovirus, and bocavirus. CONCLUSIONS: Compared to symptomatic infection, asymptomatic viral infection in infants is associated with young age, male sex, low viral load, specific viruses, and single virus detection. Asymptomatic viral infection did not result in AOM.


Asunto(s)
Otitis Media/virología , Infecciones del Sistema Respiratorio/virología , Virosis/virología , Virus/clasificación , Virus/aislamiento & purificación , Enfermedades Asintomáticas/epidemiología , Femenino , Ensayos Analíticos de Alto Rendimiento , Humanos , Lactante , Recién Nacido , Estudios Longitudinales , Masculino , Nasofaringe/virología , Otitis Media/epidemiología , Reacción en Cadena de la Polimerasa , Estudios Prospectivos , Infecciones del Sistema Respiratorio/epidemiología , Virosis/epidemiología
18.
Expert Rev Mol Diagn ; 24(3): 147-151, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37724428

RESUMEN

INTRODUCTION: Testing at the point of care (we also refer to the 'point of need'), with rapid, actionable results reported to the patient and provider within hours can impact the individual as well as public health. Faster testing is good for patients and public health outcomes during 'peace time' (outside of the pandemic setting). AREAS COVERED: Testing at the point of need was important during the COVID-19 pandemic to meet testing capacity demands, providing actionable results, and for providing testing within communities to increase access for all populations. Resources were acquired and built up dramatically during the pandemic as part of the response. With the end of the COVID-19 public health emergency and transition back to 'peace time' some testing sites have successfully shifted to using this capacity for testing for other critical needs, like sexually transmitted infection (STI) testing, and response to other seasonal diseases and for outbreak response. EXPERT OPINION: The increased testing capacity added to handle unprecedented testing volume during the COVID-19 pandemic can be repurposed for other critical infectious diseases during 'peace time' (post-COVID-19 pandemic). This maintains testing capacity for the next pandemic.


Asunto(s)
COVID-19 , Humanos , COVID-19/diagnóstico , COVID-19/epidemiología , SARS-CoV-2 , Prueba de COVID-19 , Pandemias , Preparación para una Pandemia , Pruebas en el Punto de Atención
19.
Microbiol Spectr ; 12(4): e0390823, 2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38466093

RESUMEN

Despite having high analytical sensitivities and specificities, qualitative SARS-CoV-2 nucleic acid amplification tests (NAATs) cannot distinguish infectious from non-infectious virus in clinical samples. In this study, we determined the highest cycle threshold (Ct) value of the SARS-CoV-2 targets in the Xpert Xpress SARS-CoV-2/Flu/RSV (Xpert 4plex) test that corresponded to the presence of detectable infectious SARS-CoV-2 in anterior nasal swab samples. A total of 111 individuals with nasopharyngeal swab specimens that were initially tested by the Xpert Xpress SARS-CoV-2 test were enrolled. A healthcare worker subsequently collected anterior nasal swabs from all SARS-CoV-2-positive individuals, and those specimens were tested by the Xpert 4plex test, viral culture, and laboratory-developed assays for SARS-CoV-2 replication intermediates. SARS-CoV-2 Ct values from the Xpert 4plex test were correlated with data from culture and replication intermediate testing to determine the Xpert 4plex assay Ct value that corresponded to the presence of infectious virus. Ninety-eight of the 111 (88.3%) individuals initially tested positive by the Xpert Xpress SARS-CoV-2 test. An anterior nasal swab specimen collected from positive individuals a median of 2 days later (range, 0-9 days) tested positive for SARS-CoV-2 by the Xpert 4plex test in 39.8% (39/98) of cases. Of these samples, 13 (33.3%) were considered to contain infectious virus based on the presence of cultivable virus and replication intermediates, and the highest Ct value observed for the Xpert 4plex test in these instances was 26.3. Specimens that yielded Ct values of ≤26.3 when tested by the Xpert 4plex test had a likelihood of containing infectious SARS-CoV-2; however, no infectious virus was detected in specimens with higher Ct values.IMPORTANCEUnderstanding the correlation between real-time PCR test results and the presence of infectious SARS-CoV-2 may be useful for informing patient management and workforce return-to-work or -duty. Further studies in different patient populations are needed to correlate Ct values or other biomarkers of viral replication along with the presence of infectious virus in clinical samples.


Asunto(s)
COVID-19 , Enfermedades Transmisibles , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Nasofaringe , Técnicas de Diagnóstico Molecular/métodos , Prueba de COVID-19
20.
Clin Lab Med ; 43(2): 155-165, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37169439

RESUMEN

The practical challenges of point-of-care testing (POCT) include analytical performance and quality compared with testing performed in a central laboratory and higher cost per test compared with laboratory-based tests. These challenges can be addressed with new test technology, consensus, and practice guidelines for the use of POCT, instituting a quality management system and data connectivity in the POCT setting, and studies that demonstrate evidence of clinical and economic value of POCT.


Asunto(s)
Laboratorios , Pruebas en el Punto de Atención , Sistemas de Atención de Punto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA