Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-19164055

RESUMEN

This paper presents the design of a Pipelined Analog-to-Digital Converter (ADC) for Electroencephalogram (EEG) applications with 10 bits of resolution, 1.2V of supply voltage and only 1.5 microW of power consumption using a standard 0.5 microm CMOS technology. Low-voltage and low-power operation has been achieved using Quasi-Floating-Gate (QFG) based circuits. The use of a new class-AB operational amplifier in weak inversion allows very low power consumption and high enough open loop gain. Simulation results show an energy efficiency of 0.84 pJ per quantization level, placing the converter into the state-of-the-art of low-frequency low-power ADCs.


Asunto(s)
Conversión Analogo-Digital , Compresión de Datos/métodos , Electroencefalografía/instrumentación , Procesamiento de Señales Asistido por Computador/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
2.
IEEE Trans Biomed Circuits Syst ; 2(3): 223-30, 2008 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23852971

RESUMEN

This paper presents a second-order Sigma-Delta modulator for electroencephalogram applications with 10 bits of resolution, 1.2 V of supply voltage, and only 140 nW of power consumption over a bandwidth of 25 Hz. Low-voltage operation has been achieved using quasi-floating-gate-based circuits. The use of a new class-AB operational amplifier in weak inversion allows very low power consumption. Experimental results show an energy efficiency of 1.6 pJ per quantization level, making it the most energy-efficient converter reported to date in the very low signal bandwidth range.

3.
Artículo en Inglés | MEDLINE | ID: mdl-18003199

RESUMEN

A low-voltage and low-power front-end for miniaturized, wearable EEG systems is presented. The instrumentation amplifier, which removes the electrode drift and conditions the signal for a 10-bit A/D converter, combines a chopping strategy with quasi-FGMOS (QFG) transistors to minimize low frequency noise whilst enabling operation at 1 V supply. QFG devices are also key to the A/D converter operating at 1.2 V with 70dB of SNR and an oversampling ratio of 64. The whole system consumes less than 2uW at 1.2V.


Asunto(s)
Amplificadores Electrónicos , Conversión Analogo-Digital , Diagnóstico por Computador/instrumentación , Suministros de Energía Eléctrica , Electrocardiografía Ambulatoria/instrumentación , Procesamiento de Señales Asistido por Computador/instrumentación , Diagnóstico por Computador/métodos , Diseño de Equipo , Análisis de Falla de Equipo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA