Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 128
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Gastroenterology ; 162(4): 1197-1209.e13, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34973296

RESUMEN

BACKGROUND & AIMS: Barrett's esophagus (BE) is a risk factor for esophageal adenocarcinoma but our understanding of how it evolves is poorly understood. We investigated BE gland phenotype distribution, the clonal nature of phenotypic change, and how phenotypic diversity plays a role in progression. METHODS: Using immunohistochemistry and histology, we analyzed the distribution and the diversity of gland phenotype between and within biopsy specimens from patients with nondysplastic BE and those who had progressed to dysplasia or had developed postesophagectomy BE. Clonal relationships were determined by the presence of shared mutations between distinct gland types using laser capture microdissection sequencing of the mitochondrial genome. RESULTS: We identified 5 different gland phenotypes in a cohort of 51 nondysplastic patients where biopsy specimens were taken at the same anatomic site (1.0-2.0 cm superior to the gastroesophageal junction. Here, we observed the same number of glands with 1 and 2 phenotypes, but 3 phenotypes were rare. We showed a common ancestor between parietal cell-containing, mature gastric (oxyntocardiac) and goblet cell-containing, intestinal (specialized) gland phenotypes. Similarly, we have shown a clonal relationship between cardiac-type glands and specialized and mature intestinal glands. Using the Shannon diversity index as a marker of gland diversity, we observed significantly increased phenotypic diversity in patients with BE adjacent to dysplasia and predysplasia compared to nondysplastic BE and postesophagectomy BE, suggesting that diversity develops over time. CONCLUSIONS: We showed that the range of BE phenotypes represents an evolutionary process and that changes in gland diversity may play a role in progression. Furthermore, we showed a common ancestry between gastric and intestinal-type glands in BE.


Asunto(s)
Esófago de Barrett , Neoplasias Esofágicas , Esófago de Barrett/patología , Neoplasias Esofágicas/patología , Unión Esofagogástrica/patología , Humanos , Fenotipo
2.
Br J Surg ; 110(11): 1535-1542, 2023 Oct 10.
Artículo en Inglés | MEDLINE | ID: mdl-37611141

RESUMEN

BACKGROUND: Surgical errors are acts or omissions resulting in negative consequences and/or increased operating time. This study describes surgeon-reported errors in laparoscopic cholecystectomy. METHODS: Intraoperative videos were uploaded and annotated on Touch SurgeryTM Enterprise. Participants evaluated videos for severity using a 10-point intraoperative cholecystitis grading score, and errors using Observational Clinical Human Reliability Assessment, which includes skill, consequence, and mechanism classifications. RESULTS: Nine videos were assessed by 8 participants (3 junior (specialist trainee (ST) 3-5), 2 senior trainees (ST6-8), and 3 consultants). Participants identified 550 errors. Positive relationships were seen between total operating time and error count (r2 = 0.284, P < 0.001), intraoperative grade score and error count (r2 = 0.578, P = 0.001), and intraoperative grade score and total operating time (r2 = 0.157, P < 0.001). Error counts differed significantly across intraoperative phases (H(6) = 47.06, P < 0.001), most frequently at dissection of the hepatocystic triangle (total 282; median 33.5 (i.q.r. 23.5-47.8, range 15-63)), ligation/division of cystic structures (total 124; median 13.5 (i.q.r. 12-19.3, range 10-26)), and gallbladder dissection (total 117; median 14.5 (i.q.r. 10.3-18.8, range 6-26)). There were no significant differences in error counts between juniors, seniors, and consultants (H(2) = 0.03, P = 0.987). Errors were classified differently. For dissection of the hepatocystic triangle, thermal injuries (50 in total) were frequently classified as executional, consequential errors; trainees classified thermal injuries as step done with excessive force, speed, depth, distance, time or rotation (29 out of 50), whereas consultants classified them as incorrect orientation (6 out of 50). For ligation/division of cystic structures, inappropriate clipping (60 errors in total), procedural errors were reported by junior trainees (6 out of 60), but not consultants. For gallbladder dissection, inappropriate dissection (20 errors in total) was reported in incorrect planes by consultants and seniors (6 out of 20), but not by juniors. Poor economy of movement (11 errors in total) was reported more by consultants (8 out of 11) than trainees (3 out of 11). CONCLUSION: This study suggests that surgical experience influences error interpretation, but the benefits for surgical training are currently unclear.


Asunto(s)
Colecistectomía Laparoscópica , Humanos , Colecistectomía Laparoscópica/métodos , Disección , Vesícula Biliar , Ligadura , Reproducibilidad de los Resultados
3.
Gastrointest Endosc ; 97(4): 646-654, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36460087

RESUMEN

BACKGROUND AND AIMS: We aimed to develop a computer-aided characterization system that could support the diagnosis of dysplasia in Barrett's esophagus (BE) on magnification endoscopy. METHODS: Videos were collected in high-definition magnification white-light and virtual chromoendoscopy with i-scan (Pentax Hoya, Japan) imaging in patients with dysplastic and nondysplastic BE (NDBE) from 4 centers. We trained a neural network with a Resnet101 architecture to classify frames as dysplastic or nondysplastic. The network was tested on 3 different scenarios: high-quality still images, all available video frames, and a selected sequence within each video. RESULTS: Fifty-seven patients, each with videos of magnification areas of BE (34 dysplasia, 23 NDBE), were included. Performance was evaluated by a leave-1-patient-out cross-validation method. In all, 60,174 (39,347 dysplasia, 20,827 NDBE) magnification video frames were used to train the network. The testing set included 49,726 i-scan-3/optical enhancement magnification frames. On 350 high-quality still images, the network achieved a sensitivity of 94%, specificity of 86%, and area under the receiver operator curve (AUROC) of 96%. On all 49,726 available video frames, the network achieved a sensitivity of 92%, specificity of 82%, and AUROC of 95%. On a selected sequence of frames per case (total of 11,471 frames), we used an exponentially weighted moving average of classifications on consecutive frames to characterize dysplasia. The network achieved a sensitivity of 92%, specificity of 84%, and AUROC of 96%. The mean assessment speed per frame was 0.0135 seconds (SD ± 0.006). CONCLUSION: Our network can characterize BE dysplasia with high accuracy and speed on high-quality magnification images and sequence of video frames, moving it toward real-time automated diagnosis.


Asunto(s)
Esófago de Barrett , Neoplasias Esofágicas , Humanos , Esófago de Barrett/diagnóstico , Neoplasias Esofágicas/diagnóstico por imagen , Esofagoscopía/métodos , Hiperplasia , Computadores
4.
Epidemiol Infect ; 151: e21, 2023 01 18.
Artículo en Inglés | MEDLINE | ID: mdl-36650731

RESUMEN

SARS-CoV-2 has severely affected capacity in the National Health Service (NHS), and waiting lists are markedly increasing due to downtime of up to 50 min between patient consultations/procedures, to reduce the risk of infection. Ventilation accelerates this air cleaning, but retroactively installing built-in mechanical ventilation is often cost-prohibitive. We investigated the effect of using portable air cleaners (PAC), a low-energy and low-cost alternative, to reduce the concentration of aerosols in typical patient consultation/procedure environments. The experimental setup consisted of an aerosol generator, which mimicked the subject affected by SARS-CoV-19, and an aerosol detector, representing a subject who could potentially contract SARS-CoV-19. Experiments of aerosol dispersion and clearing were undertaken in situ in a variety of rooms with two different types of PAC in various combinations and positions. Correct use of PAC can reduce the clearance half-life of aerosols by 82% compared to the same indoor-environment without any ventilation, and at a broadly equivalent rate to built-in mechanical ventilation. In addition, the highest level of aerosol concentration measured when using PAC remains at least 46% lower than that when no mitigation is used, even if the PAC's operation is impeded due to placement under a table. The use of PAC leads to significant reductions in the level of aerosol concentration, associated with transmission of droplet-based airborne diseases. This could enable NHS departments to reduce the downtime between consultations/procedures.


Asunto(s)
Filtros de Aire , COVID-19 , Humanos , SARS-CoV-2 , Medicina Estatal , Aerosoles y Gotitas Respiratorias , Hospitales
5.
J Gastroenterol Hepatol ; 38(5): 768-774, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36652526

RESUMEN

BACKGROUND AND AIM: Lack of visual recognition of colorectal polyps may lead to interval cancers. The mechanisms contributing to perceptual variation, particularly for subtle and advanced colorectal neoplasia, have scarcely been investigated. We aimed to evaluate visual recognition errors and provide novel mechanistic insights. METHODS: Eleven participants (seven trainees and four medical students) evaluated images from the UCL polyp perception dataset, containing 25 polyps, using eye-tracking equipment. Gaze errors were defined as those where the lesion was not observed according to eye-tracking technology. Cognitive errors occurred when lesions were observed but not recognized as polyps by participants. A video study was also performed including 39 subtle polyps, where polyp recognition performance was compared with a convolutional neural network. RESULTS: Cognitive errors occurred more frequently than gaze errors overall (65.6%), with a significantly higher proportion in trainees (P = 0.0264). In the video validation, the convolutional neural network detected significantly more polyps than trainees and medical students, with per-polyp sensitivities of 79.5%, 30.0%, and 15.4%, respectively. CONCLUSIONS: Cognitive errors were the most common reason for visual recognition errors. The impact of interventions such as artificial intelligence, particularly on different types of perceptual errors, needs further investigation including potential effects on learning curves. To facilitate future research, a publicly accessible visual perception colonoscopy polyp database was created.


Asunto(s)
Pólipos del Colon , Neoplasias Colorrectales , Humanos , Pólipos del Colon/diagnóstico , Pólipos del Colon/patología , Tecnología de Seguimiento Ocular , Inteligencia Artificial , Colonoscopía/métodos , Neoplasias Colorrectales/diagnóstico , Neoplasias Colorrectales/patología
6.
Dig Endosc ; 35(5): 645-655, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-36527309

RESUMEN

OBJECTIVES: Convolutional neural networks (CNN) for computer-aided diagnosis of polyps are often trained using high-quality still images in a single chromoendoscopy imaging modality with sessile serrated lesions (SSLs) often excluded. This study developed a CNN from videos to classify polyps as adenomatous or nonadenomatous using standard narrow-band imaging (NBI) and NBI-near focus (NBI-NF) and created a publicly accessible polyp video database. METHODS: We trained a CNN with 16,832 high and moderate quality frames from 229 polyp videos (56 SSLs). It was evaluated with 222 polyp videos (36 SSLs) across two test-sets. Test-set I consists of 14,320 frames (157 polyps, 111 diminutive). Test-set II, which is publicly accessible, 3317 video frames (65 polyps, 41 diminutive), which was benchmarked with three expert and three nonexpert endoscopists. RESULTS: Sensitivity for adenoma characterization was 91.6% in test-set I and 89.7% in test-set II. Specificity was 91.9% and 88.5%. Sensitivity for diminutive polyps was 89.9% and 87.5%; specificity 90.5% and 88.2%. In NBI-NF, sensitivity was 89.4% and 89.5%, with a specificity of 94.7% and 83.3%. In NBI, sensitivity was 85.3% and 91.7%, with a specificity of 87.5% and 90.0%, respectively. The CNN achieved preservation and incorporation of valuable endoscopic innovations (PIVI)-1 and PIVI-2 thresholds for each test-set. In the benchmarking of test-set II, the CNN was significantly more accurate than nonexperts (13.8% difference [95% confidence interval 3.2-23.6], P = 0.01) with no significant difference with experts. CONCLUSIONS: A single CNN can differentiate adenomas from SSLs and hyperplastic polyps in both NBI and NBI-NF. A publicly accessible NBI polyp video database was created and benchmarked.


Asunto(s)
Adenoma , Pólipos del Colon , Neoplasias Colorrectales , Aprendizaje Profundo , Humanos , Pólipos del Colon/diagnóstico por imagen , Pólipos del Colon/patología , Colonoscopía/métodos , Neoplasias Colorrectales/patología , Adenoma/diagnóstico por imagen , Adenoma/patología , Imagen de Banda Estrecha/métodos
7.
Surg Innov ; 30(1): 45-49, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36377296

RESUMEN

BACKGROUND: Fluorescence angiography in colorectal surgery is a technique that may lead to lower anastomotic leak rates. However, the interpretation of the fluorescent signal is not standardised and there is a paucity of data regarding interobserver agreement. The aim of this study is to assess interobserver variability in selection of the transection point during fluorescence angiography before anastomosis. METHODS: An online survey with still images of fluorescence angiography was distributed through colorectal surgery channels containing images from 13 patients where several areas for transection were displayed to be chosen by raters. Agreement was assessed overall and between pre-planned rater cohorts (experts vs non-experts; trainees vs consultants; colorectal specialists vs non colorectal specialists), using Fleiss' kappa statistic. RESULTS: 101 raters had complete image ratings. No significant difference was found between raters when choosing a point of optimal bowel transection based on fluorescence angiography still images. There was no difference between pre-planned cohorts analysed (experts vs non-experts; trainees vs consultants; colorectal specialists vs non colorectal specialists). Agreement between these cohorts was poor (<.26). CONCLUSION: Whilst there is no learning curve for the technical adoption of FA, understanding the fluorescent signal characteristics is key to successful use. We found significant variation exists in interpretation of static fluorescence angiography data. Further efforts should be employed to standardise fluorescence angiography assessment.


Asunto(s)
Neoplasias Colorrectales , Humanos , Angiografía con Fluoresceína/métodos , Variaciones Dependientes del Observador , Neoplasias Colorrectales/cirugía , Verde de Indocianina , Anastomosis Quirúrgica/métodos , Fuga Anastomótica , Colorantes
8.
J Relig Health ; 62(1): 608-626, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36002758

RESUMEN

The COVID-19 pandemic has led to restrictions such as social distancing and mandatory wearing of face masks. Singing and religious gatherings have been linked to infection clusters, and between 2020 and 2021 indoor congregational singing and chanting were prohibited in the United Kingdom. We evaluated attitudes to face mask use and their acceptability as well as changes within places of worship since their reopening in July up to autumn 2020. In this cross-sectional study, participants were recruited using convenience sampling through selective targeting of religious organisations and social media. Participants self-enrolled and completed an online questionnaire, which included open and closed questions. We used multivariable logistic regression to identify factors associated with face mask acceptability. We performed thematic analysis to evaluate responses to open questions. A total of 939 participants were included in the analysis. Median age was 52.7 years and 66.1% were female, while 80.7% identified as Christian. A majority (672/861; 78.0%) of participants would find it acceptable to wear a face mask and reduce their singing or chanting volume if required, even though 428/681 (49.1%) found face masks to be uncomfortable. Multivariable regression found that younger age was associated with a higher acceptability of face masks (adjusted OR (aOR): 0.98 (95% confidence interval (95% CI) 0.96-1.00), p = 0.0218). The majority of respondents stated that religious services had become shorter, attended by fewer people and with reduced singing or chanting. Most (869/893, 97.3%) stated their place of worship complied with government guidelines, with 803/887 (90.5%) reported that their place of worship enforced face mask wearing and 793/887 (89.4%) at least moderately happy with precaution measures. Our study demonstrates the significant impact of COVID-19 in places of worship but a high degree of compliance with guidelines. Face masks, despite practical difficulties, appeared to be more acceptable if there was an incentive of being able to sing and chant.


Asunto(s)
COVID-19 , Máscaras , Femenino , Humanos , Persona de Mediana Edad , Masculino , Estudios Transversales , Pandemias/prevención & control , COVID-19/prevención & control , Reino Unido
9.
Clin Gastroenterol Hepatol ; 20(2): e51-e63, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-33581357

RESUMEN

BACKGROUND & AIMS: A non-endoscopic approach to Barrett's esophagus (BE) surveillance after radiofrequency ablation (RFA) would offer a less invasive method for monitoring. We assessed the test characteristics and cost-effectiveness of the Cytosponge (Medtronic, Minneapolis, MN) in post-RFA patients. METHODS: We performed a multicenter study of dysplastic BE patients after at least one round of RFA. A positive Cytosponge before endoscopy was defined as intestinal metaplasia (IM) on cytological assessment and/or TFF3 immunohistochemistry. Sensitivity, specificity, and receiver operator characteristic (ROC) curves were calculated. Multivariable regression was used to estimate the odds of a positive Cytosponge in BE. A microsimulation cost-effectiveness model was performed to assess outcomes of various surveillance strategies: endoscopy-only, Cytosponge-only, and alternating endoscopy/Cytosponge. RESULTS: Of 234 patients, Cytosponge adequately sampled the distal esophagus in 175 (75%). Of the 142 with both endoscopic and histologic data, 19 (13%) had residual/recurrent BE. For detecting any residual Barrett's, Cytosponge had a sensitivity of 74%, specificity of 85%, accuracy of 84%, and ROC curve showed an area under the curve of 0.74. The adjusted odds of a positive Cytosponge in BE were 17.1 (95% CI, 5.2-55.9). Cytosponge-only surveillance dominated all the surveillance strategies, being both less costly and more effective. Cytosponge-only surveillance required <1/4th the endoscopies, resulting in only 0.69 additional EAC cases/1000 patients, and no increase in EAC deaths when compared to currently-practiced endoscopy-only surveillance. CONCLUSIONS: A positive Cytosponge test was strongly associated with residual BE after ablation. While the assay needs further refinement in this context, it could serve as a cost-effective surveillance examination.


Asunto(s)
Esófago de Barrett , Neoplasias Esofágicas , Esófago de Barrett/complicaciones , Esófago de Barrett/diagnóstico , Esófago de Barrett/cirugía , Análisis Costo-Beneficio , Endoscopía Gastrointestinal , Neoplasias Esofágicas/patología , Esofagoscopía , Humanos , Metaplasia/complicaciones
10.
Gastrointest Endosc ; 96(2): 223-233, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35189088

RESUMEN

BACKGROUND AND AIMS: Long-term durability data for effectiveness of radiofrequency ablation (RFA) to prevent esophageal adenocarcinoma in patients with dysplastic Barrett's esophagus (BE) are lacking. METHODS: We prospectively collected data from 2535 patients with BE (mean length, 5.2 cm; range, 1-20) and neoplasia (20% low-grade dysplasia, 54% high-grade dysplasia, 26% intramucosal carcinoma) who underwent RFA therapy across 28 UK hospitals. We assessed rates of invasive cancer and performed detailed analyses of 1175 patients to assess clearance rates of dysplasia (CR-D) and intestinal metaplasia (CR-IM) within 2 years of starting RFA therapy. We assessed relapses and rates of return to CR-D (CR-D2) and CR-IM (CR-IM2) after further therapy. CR-D and CR-IM were confirmed by an absence of dysplasia and intestinal metaplasia on biopsy samples taken at 2 consecutive endoscopies. RESULTS: Ten years after starting treatment, the Kaplan-Meier (KM) cancer rate was 4.1% with a crude incidence rate of .52 per 100 patient-years. CR-D and CR-IM after 2 years of therapy were 88% and 62.6%, respectively. KM relapse rates were 5.9% from CR-D and 18.7% from CR-IM at 8 years, with most occurring in the first 2 years. Both were successfully retreated with rates of CR-D2 of 63.4% and CR-IM2 of 70.0% 2 years after retreatment. EMR before RFA increased the likelihood of rescue EMR from 17.2% to 41.7% but did not affect the rate of CR-D, whereas rescue EMR after RFA commenced reduced CR-D from 91.4% to 79.7% (χ2P < .001). CONCLUSIONS: RFA treatment is effective and durable to prevent esophageal adenocarcinoma. Most treatment relapses occur early and can be successfully retreated.


Asunto(s)
Adenocarcinoma , Esófago de Barrett , Ablación por Catéter , Neoplasias Esofágicas , Adenocarcinoma/patología , Adenocarcinoma/cirugía , Esófago de Barrett/patología , Esófago de Barrett/cirugía , Neoplasias Esofágicas/patología , Neoplasias Esofágicas/cirugía , Esofagoscopía , Humanos , Metaplasia , Recurrencia Local de Neoplasia/epidemiología , Recurrencia Local de Neoplasia/cirugía , Sistema de Registros , Resultado del Tratamiento , Reino Unido/epidemiología
11.
Surg Endosc ; 36(1): 598-606, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-33547491

RESUMEN

BACKGROUND: Radio-frequency ablation (RFA) for Barrett's oesophagus (BE)-related neoplasia is currently used after endoscopic resection of visible neoplasia. The HALO 360 balloon has been used to ablate long segment BE. The Barrx™ 360 Express RFA self-sizing catheter ('RFA Express') may potentially allow quicker ablation times and improved treatment outcomes. The aim of this paper is to present real world data on the use of the 360 Express Device. METHODS: Centres in the UK and Ireland submitted cases where the RFA Express was used. The primary outcome was regression of BE at 3 months. Secondary outcomes were the rate of symptomatic stricture formation and resolution of intestinal metaplasia (CR-IM) and dysplasia (CR-D) at End of Treatment (EoT). RESULTS: 11 centres submitted 123 consecutive patients. 112 had a follow up endoscopy. The median age was 67 years (IQR 62-75). 3 dosimetries were used. The mean reduction in Circumferential (C) length was 78% ± 36 and mean reduction in Maximal length (M) was 55% ± 36. 17 patients (15%) developed strictures requiring dilation. There was a higher rate of stricture formation when the 12 J energy was used (p < 0.05). 47 patients had EoT biopsies, 40 (85%) had CR-D and 34(76%) had CR-IM. CONCLUSIONS: The RFA 360 Express catheter shows reduction in length of baseline BE at 3 months after index treatment, and eradication of intestinal metaplasia and dysplasia at 12 months similar to other studies with earlier devices. It appears that the symptomatic stricture rate is slightly higher than previous series with the HALO 360 catheter. This study was performed as part of the HALO registry and has been approved by the Research Ethics Committee - MREC Number 08/H0714/27 Local project reference 08/0104 Project ID 15,033 IRAS Number 54678 EudraCT 2009-015980-1. Registered on ISRCTN as below: ISRCTN93069556. https://doi.org/10.1186/ISRCTN93069556.


Asunto(s)
Esófago de Barrett , Ablación por Catéter , Neoplasias Esofágicas , Anciano , Esófago de Barrett/complicaciones , Esófago de Barrett/cirugía , Ablación por Catéter/métodos , Catéteres , Neoplasias Esofágicas/complicaciones , Neoplasias Esofágicas/cirugía , Esofagoscopía/métodos , Humanos , Irlanda , Resultado del Tratamiento , Reino Unido
12.
Dig Endosc ; 34(4): 862-869, 2022 May.
Artículo en Inglés | MEDLINE | ID: mdl-34748665

RESUMEN

OBJECTIVES: There is uncertainty regarding the efficacy of artificial intelligence (AI) software to detect advanced subtle neoplasia, particularly flat lesions and sessile serrated lesions (SSLs), due to low prevalence in testing datasets and prospective trials. This has been highlighted as a top research priority for the field. METHODS: An AI algorithm was evaluated on four video test datasets containing 173 polyps (35,114 polyp-positive frames and 634,988 polyp-negative frames) specifically enriched with flat lesions and SSLs, including a challenging dataset containing subtle advanced neoplasia. The challenging dataset was also evaluated by eight endoscopists (four independent, four trainees, according to the Joint Advisory Group on gastrointestinal endoscopy [JAG] standards in the UK). RESULTS: In the first two video datasets, the algorithm achieved per-polyp sensitivities of 100% and 98.9%. Per-frame sensitivities were 84.1% and 85.2%. In the subtle dataset, the algorithm detected a significantly higher number of polyps (P < 0.0001), compared to JAG-independent and trainee endoscopists, achieving per-polyp sensitivities of 79.5%, 37.2% and 11.5%, respectively. Furthermore, when considering subtle polyps detected by both the algorithm and at least one endoscopist, the AI detected polyps significantly faster on average. CONCLUSIONS: The AI based algorithm achieved high per-polyp sensitivities for advanced colorectal neoplasia, including flat lesions and SSLs, outperforming both JAG independent and trainees on a very challenging dataset containing subtle lesions that could have been overlooked easily and contribute to interval colorectal cancer. Further prospective trials should evaluate AI to detect subtle advanced neoplasia in higher risk populations for colorectal cancer.


Asunto(s)
Pólipos del Colon , Neoplasias Colorrectales , Algoritmos , Inteligencia Artificial , Pólipos del Colon/diagnóstico , Pólipos del Colon/patología , Colonoscopía , Neoplasias Colorrectales/diagnóstico , Neoplasias Colorrectales/patología , Humanos
13.
Am J Gastroenterol ; 116(2): 280-288, 2021 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-33136563

RESUMEN

INTRODUCTION: Esophagogastric junction outflow obstruction (EGJOO) defined on high-resolution esophageal manometry (HRM) poses a management dilemma given marked variability in clinical manifestations. We hypothesized that findings from provocative testing (rapid drink challenge and solid swallows) could determine the clinical relevance of EGJOO. METHODS: In a retrospective cohort study, we included consecutive subjects between May 2016 and January 2020 with EGJOO. Standard HRM with 5-mL water swallows was followed by provocative testing. Barium esophagography findings were obtained. Cases with structural obstruction were separated from functional EGJOO, with the latter categorized as symptom-positive or symptom-negative. Only symptom-positive subjects were considered for achalasia-type therapies. Sensitivity and specificity for clinically relevant EGJOO during 5-mL water swallows, provocative testing, and barium were calculated. RESULTS: Of the 121 EGJOO cases, 76% had dysphagia and 25% had holdup on barium. Ninety-seven cases (84%) were defined as functional EGJOO. Symptom-positive EGJOO subjects were more likely to demonstrate abnormal motility and pressurization patterns and to reproduce symptoms during provocative testing, but not with 5-mL water swallows. Twenty-nine (30%) functional EGJOO subjects underwent achalasia-type therapy, with symptomatic response in 26 (90%). Forty-eight (49%) functional EGJOO cases were managed conservatively, with symptom remission in 78%. Although specificity was similar, provocative testing demonstrated superior sensitivity in identifying treatment responders from spontaneously remitting EGJOO (85%) compared with both 5-mL water swallows (54%; P < 0.01) and barium esophagography (54%; P = 0.02). DISCUSSION: Provocative testing during HRM is highly accurate in identifying clinically relevant EGJOO that benefits from therapy and should be routinely performed as part of the manometric protocol.


Asunto(s)
Deglución/fisiología , Trastornos de la Motilidad Esofágica/fisiopatología , Unión Esofagogástrica/fisiopatología , Manometría , Adulto , Anciano , Compuestos de Bario , Trastornos de la Motilidad Esofágica/diagnóstico , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radiografía , Estudios Retrospectivos
14.
Gastrointest Endosc ; 94(2): 273-281, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33549586

RESUMEN

BACKGROUND AND AIMS: Intrapapillary capillary loops (IPCLs) are microvascular structures that correlate with the invasion depth of early squamous cell neoplasia and allow accurate prediction of histology. Artificial intelligence may improve human recognition of IPCL patterns and prediction of histology to allow prompt access to endoscopic therapy for early squamous cell neoplasia where appropriate. METHODS: One hundred fifteen patients were recruited at 2 academic Taiwanese hospitals. Magnification endoscopy narrow-band imaging videos of squamous mucosa were labeled as dysplastic or normal according to their histology, and IPCL patterns were classified by consensus of 3 experienced clinicians. A convolutional neural network (CNN) was trained to classify IPCLs, using 67,742 high-quality magnification endoscopy narrow-band images by 5-fold cross validation. Performance measures were calculated to give an average F1 score, accuracy, sensitivity, and specificity. A panel of 5 Asian and 4 European experts predicted the histology of a random selection of 158 images using the Japanese Endoscopic Society IPCL classification; accuracy, sensitivity, specificity, positive and negative predictive values were calculated. RESULTS: Expert European Union (EU) and Asian endoscopists attained F1 scores (a measure of binary classification accuracy) of 97.0% and 98%, respectively. Sensitivity and accuracy of the EU and Asian clinicians were 97%, 98% and 96.9%, 97.1%, respectively. The CNN average F1 score was 94%, sensitivity 93.7%, and accuracy 91.7%. Our CNN operates at video rate and generates class activation maps that can be used to visually validate CNN predictions. CONCLUSIONS: We report a clinically interpretable CNN developed to predict histology based on IPCL patterns, in real time, using the largest reported dataset of images for this purpose. Our CNN achieved diagnostic performance comparable with an expert panel of endoscopists.


Asunto(s)
Carcinoma de Células Escamosas , Neoplasias Esofágicas , Inteligencia Artificial , Carcinoma de Células Escamosas/diagnóstico por imagen , Células Epiteliales , Neoplasias Esofágicas/diagnóstico por imagen , Humanos , Redes Neurales de la Computación
15.
Endoscopy ; 53(1): 36-43, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32459000

RESUMEN

BACKGROUND: Upper gastrointestinal bleeding (UGIB) is a leading cause of morbidity and is associated with a 2 % - 17 % mortality rate in the UK and USA. Bleeding peptic ulcers account for 50 % of UGIB cases. Endoscopic intervention in a timely manner can improve outcomes. Hemostatic spray is an endoscopic hemostatic powder for GI bleeding. This multicenter registry was created to collect data prospectively on the immediate endoscopic hemostasis of GI bleeding in patients with peptic ulcer disease when hemostatic spray is applied as endoscopic monotherapy, dual therapy, or rescue therapy. METHODS: Data were collected prospectively (January 2016 - March 2019) from 14 centers in the UK, France, Germany, and the USA. The application of hemostatic spray was decided upon at the endoscopist's discretion. RESULTS: 202 patients with UGIB secondary to peptic ulcers were recruited. Immediate hemostasis was achieved in 178/202 patients (88 %), 26/154 (17 %) experienced rebleeding, 21/175 (12 %) died within 7 days, and 38/175 (22 %) died within 30 days (all-cause mortality). Combination therapy of hemostatic spray with other endoscopic modalities had an associated lower 30-day mortality (16 %, P < 0.05) compared with monotherapy or rescue therapy. There were high immediate hemostasis rates across all peptic ulcer disease Forrest classifications. CONCLUSIONS: This is the largest case series of outcomes of peptic ulcer bleeding treated with hemostatic spray, with high immediate hemostasis rates for bleeding peptic ulcers.


Asunto(s)
Hemostasis Endoscópica , Hemostáticos , Úlcera Péptica , Francia , Alemania , Humanos , Minerales , Recurrencia Local de Neoplasia , Úlcera Péptica Hemorrágica/terapia , Polvos , Recurrencia , Sistema de Registros , Resultado del Tratamiento
16.
Endoscopy ; 53(9): 893-901, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33167043

RESUMEN

BACKGROUND : Artificial intelligence (AI) research in colonoscopy is progressing rapidly but widespread clinical implementation is not yet a reality. We aimed to identify the top implementation research priorities. METHODS : An established modified Delphi approach for research priority setting was used. Fifteen international experts, including endoscopists and translational computer scientists/engineers, from nine countries participated in an online survey over 9 months. Questions related to AI implementation in colonoscopy were generated as a long-list in the first round, and then scored in two subsequent rounds to identify the top 10 research questions. RESULTS : The top 10 ranked questions were categorized into five themes. Theme 1: clinical trial design/end points (4 questions), related to optimum trial designs for polyp detection and characterization, determining the optimal end points for evaluation of AI, and demonstrating impact on interval cancer rates. Theme 2: technological developments (3 questions), including improving detection of more challenging and advanced lesions, reduction of false-positive rates, and minimizing latency. Theme 3: clinical adoption/integration (1 question), concerning the effective combination of detection and characterization into one workflow. Theme 4: data access/annotation (1 question), concerning more efficient or automated data annotation methods to reduce the burden on human experts. Theme 5: regulatory approval (1 question), related to making regulatory approval processes more efficient. CONCLUSIONS : This is the first reported international research priority setting exercise for AI in colonoscopy. The study findings should be used as a framework to guide future research with key stakeholders to accelerate the clinical implementation of AI in endoscopy.


Asunto(s)
Inteligencia Artificial , Colonoscopía , Técnica Delphi , Humanos
17.
J Gastroenterol Hepatol ; 36(11): 3027-3032, 2021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-34132412

RESUMEN

BACKGROUND AND AIM: Upper gastrointestinal tumors account for 5% of upper gastrointestinal bleeds. These patients are challenging to treat due to the diffuse nature of the neoplastic bleeding lesions, high rebleeding rates, and significant transfusion requirements. TC-325 (Cook Medical, North Carolina, USA) is a hemostatic powder for gastrointestinal bleeding. The aim of this study was to examine the outcomes of upper gastrointestinal bleeds secondary to tumors treated with Hemospray therapy. METHODS: Data were prospectively collected on the use of Hemospray from 17 centers. Hemospray was used during emergency endoscopy for upper gastrointestinal bleeds secondary to tumors at the discretion of the endoscopist as a monotherapy, dual therapy with standard hemostatic techniques, or rescue therapy. RESULTS: One hundred and five patients with upper gastrointestinal bleeds secondary to tumors were recruited. The median Blatchford score at baseline was 10 (interquartile range [IQR], 7-12). The median Rockall score was 8 (IQR, 7-9). Immediate hemostasis was achieved in 102/105 (97%) patients, 15% of patients had a 30-day rebleed, 20% of patients died within 30 days (all-cause mortality). There was a significant improvement in transfusion requirements following treatment (P < 0.001) when comparing the number of units transfused 3 weeks before and after treatment. The mean reduction was one unit per patient. CONCLUSIONS: Hemospray achieved high rates of immediate hemostasis, with comparable rebleed rates following treatment of tumor-related upper gastrointestinal bleeds. Hemospray helped in improving transfusion requirements in these patients. This allows for patient stabilization and bridges towards definitive surgery or radiotherapy to treat the underlying tumor.


Asunto(s)
Hemorragia Gastrointestinal , Neoplasias Gastrointestinales , Hemostasis Endoscópica , Hemostáticos , Minerales , Anciano , Anciano de 80 o más Años , Neoplasias Duodenales/complicaciones , Neoplasias Esofágicas/complicaciones , Femenino , Hemorragia Gastrointestinal/etiología , Hemorragia Gastrointestinal/terapia , Neoplasias Gastrointestinales/complicaciones , Hemostáticos/administración & dosificación , Hemostáticos/uso terapéutico , Humanos , Masculino , Persona de Mediana Edad , Minerales/administración & dosificación , Minerales/uso terapéutico , Polvos , Recurrencia , Sistema de Registros , Neoplasias Gástricas/complicaciones , Resultado del Tratamiento
18.
Dis Esophagus ; 34(8)2021 Aug 10.
Artículo en Inglés | MEDLINE | ID: mdl-33618359

RESUMEN

Oesophageal cancer is the sixth commonest cause of overall cancer mortality. Clinical staging utilizes multiple imaging modalities to guide treatment and prognostication. T2N0 oesophageal cancer is a treatment threshold for neoadjuvant therapy. Data on accuracy of current clinical staging tests for this disease subgroup are conflicting. We performed a meta-analysis of all primary studies comparing clinical staging accuracy using multiple imaging modalities (index test) to histopathological staging following oesophagectomy (reference standard) in T2N0 oesophageal cancer. Patients that underwent neoadjuvant therapy were excluded. Electronic databases (MEDLINE, Embase, Cochrane Library) were searched up to September 2019. The primary outcome was diagnostic accuracy of combined T&N clinical staging. Publication date, first recruitment date, number of centers, sample size and geographical location main histological subtype were evaluated as potential sources of heterogeneity. The search strategy identified 1,199 studies. Twenty studies containing 5,213 patients met the inclusion criteria. Combined T&N staging accuracy was 19% (95% CI, 15-24); T staging accuracy was 29% (95% CI, 24-35); percentage of patients with T downstaging was 41% (95% CI, 33-50); percentage of patients with T upstaging was 28% (95% CI, 24-32) and percentage of patients with N upstaging was 34% (95% CI, 30-39). Significant sources of heterogeneity included the number of centers, sample size and study region. T2N0 oesophageal cancer staging remains inaccurate. A significant proportion of patients were downstaged (could have received endotherapy) or upstaged (should have received neoadjuvant chemotherapy). These findings were largely unchanged over the past two decades highlighting an urgent need for more accurate staging tests for this subgroup of patients.


Asunto(s)
Neoplasias Esofágicas , Neoplasias Esofágicas/patología , Esofagectomía , Humanos , Terapia Neoadyuvante , Estadificación de Neoplasias , Sensibilidad y Especificidad
19.
BMC Surg ; 21(1): 123, 2021 Mar 08.
Artículo en Inglés | MEDLINE | ID: mdl-33685437

RESUMEN

Surgical training in the UK and Ireland has faced challenges following the implementation of the European Working Time Directive and postgraduate training reform. The health services are undergoing a digital transformation; digital technology is remodelling the delivery of surgical care and surgical training. This review aims to critically evaluate key issues in laparoscopic general surgical training and the digital technology such as virtual and augmented reality, telementoring and automated workflow analysis and surgical skills assessment. We include pre-clinical, proof of concept research and commercial systems that are being developed to provide solutions. Digital surgical technology is evolving through interdisciplinary collaboration to provide widespread access to high-quality laparoscopic general surgery training and assessment. In the future this could lead to integrated, context-aware systems that support surgical teams in providing safer surgical care.


Asunto(s)
Tecnología Digital , Cirugía General , Laparoscopía , Cirugía General/educación , Humanos , Irlanda , Laparoscopía/educación , Reino Unido
20.
Gastrointest Endosc ; 92(3): 543-550.e1, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32145288

RESUMEN

BACKGROUND AND AIMS: Endoscopic resections and radiofrequency ablation (RFA) are the established treatments for Barrett's-associated dysplasia and early esophageal neoplasia. The UK RFA Registry collects patient outcomes from 24 centers treating patients in the United Kingdom and Ireland. Learning curves for treatment of Barrett's dysplasia and the impact of center caseload on patient outcomes is still unknown. METHODS: We examined outcomes of 678 patients treated with RFA in the UK Registry using risk-adjusted cumulative sum control chart (RA-CUSUM) analysis to identify change points in complete resolution of intestinal metaplasia (CR-IM) and complete resolution of dysplasia (CR-D) outcomes. We compared outcomes between those treated at high-volume (>100 enrolled patients), medium-volume (51-100), and low-volume (<50) centers. RESULTS: There was no association between center volume and CR-IM and CR-D rates, but recurrence rates were lower in high-volume versus low-volume centers (log rank P = .001). There was a significant change point for outcomes at 12 cases for CR-D (reduction from 24.5% to 10.4%; P < .001) and at 18 cases for CR-IM (30.7% to 18.6%; P < .001) from RA-CUSUM curve analysis. CONCLUSION: Our data suggest that 18 supervised cases of endoscopic ablation may be required before competency in endoscopic treatment of Barrett's dysplasia can be achieved. The difference in outcomes between a high-volume and low-volume center does not support further centralization of services to only high-volume centers.


Asunto(s)
Esófago de Barrett , Esófago de Barrett/cirugía , Ablación por Catéter , Neoplasias Esofágicas/cirugía , Esofagoscopía , Estudios de Seguimiento , Humanos , Curva de Aprendizaje , Recurrencia Local de Neoplasia , Lesiones Precancerosas/cirugía , Resultado del Tratamiento , Reino Unido
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA