Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Abdom Imaging ; 40(2): 251-7, 2015 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-25139642

RESUMEN

PURPOSE: Pure iterative reconstruction (Pure IR) has been proposed as a solution to improve diagnostic quality of low dose CT images. We assess the performance of model based iterative reconstruction (MBIR) in improving conventional dose CT enterography (CTE) images. METHODS: 43 Crohn's patients (27 female) (38.5 ± 12.98 years) referred for CTE were included. Images were reconstructed with pure IR (MBIR, General Electric Healthcare) in addition to standard department protocol (reconstructed with hybrid iterative reconstruction (Hybrid IR) [60% filtered back projection/40% adaptive statistical IR (General Electric Healthcare)]. Image quality was assessed objectively and subjectively at 6 anatomical levels. Clinical interpretation was undertaken in consensus by 2 blinded radiologists along with 2 non-blinded readers ('gold standard'). Results were analyzed using Statistical Package for Social Scientists. RESULTS: Mean effective radiation dose was 6.05 ± 2.84 mSv (size specific dose estimates 9.25 ± 2.9 mGy). Objective and subjective assessment yielded 6106 data points. Pure IR images significantly outperformed those using standard reconstruction techniques across all subjective (p < 0.001 for all comparisons) (noise, contrast resolution, spatial resolution, streak artifact, axial diagnostic acceptability, coronal diagnostic acceptability) and objective (p < 0.004) (noise, signal-to-noise ratio) parameters. Clinical reads of the pure IR images agreed more closely with the gold standard reads than the hybrid IR image reads in terms of overall Crohn's activity grade (κ = 0.630, 0.308) and detection of acute complications (κ = 1.0, 0.896). Results were comparable for bowel wall disease severity assessment (κ = 0.523, 0.593). CONCLUSIONS: Pure IR considerably improves image quality of conventional dose CTE images and therefore its use should be expanded beyond low dose protocols to improving image quality at conventional dose CT imaging.


Asunto(s)
Enfermedad de Crohn/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Dosis de Radiación , Interpretación de Imagen Radiográfica Asistida por Computador , Tomografía Computarizada por Rayos X , Adolescente , Adulto , Anciano , Medios de Contraste , Femenino , Tracto Gastrointestinal/diagnóstico por imagen , Humanos , Yohexol , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Intensificación de Imagen Radiográfica , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA