Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Clin Microbiol ; 51(9): 2815-21, 2013 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-23616453

RESUMEN

For optimal antiviral therapy, the hepatitis C virus (HCV) genotype needs to be determined, as it remains a strong predictor of sustained viral response. In this study, we assessed the number of HCV genotyping results that could not be determined using the commercially available line probe assay (LiPA) (Versant hepatitis C virus genotype 2.0 assay) in a large international panel of samples from 9,874 HCV-positive patients. In-house sequencing assays targeting the 5' untranslated region (UTR), core region, NS3 region, and NS5B region of the HCV genome and phylogenetic analyses were used to resolve these LiPA failures. Among all cases, the genotypes of 51 samples (0.52%) could not be determined with the LiPA. These undetermined results were observed more frequently among samples from non-European regions (mainly the Arabian Peninsula). The use of sequencing assays coupled with phylogenetic analysis provided reliable genotype results for 86% of the LiPA failures, which exhibited higher rates of genotypes 4, 5, and 6 than did LiPA-resolved genotypes. As expected, the 5' UTR was not sufficiently variable for clear discrimination between genotypes 1 and 6, but it also resulted in errors in classification of some genotype 3 and 4 cases using well-known Web-based BLAST programs. This study demonstrates the low frequency of genotyping failures with the Versant hepatitis C virus genotype 2.0 assay (LiPA) and also underlines the need for a complex combination of sequences and phylogenetic analyses in order to genotype these particular HCV strains correctly.


Asunto(s)
Reacciones Falso Negativas , Hepacivirus/clasificación , Hepacivirus/genética , ARN Viral/genética , Análisis de Secuencia de ADN , Adulto , Anciano , Secuencia de Bases , Femenino , Variación Genética , Genotipo , Hepatitis C/diagnóstico , Hepatitis C/virología , Humanos , Masculino , Persona de Mediana Edad , Técnicas de Diagnóstico Molecular/métodos , Datos de Secuencia Molecular , Mutación , Virología/métodos
2.
J Clin Microbiol ; 51(5): 1428-33, 2013 May.
Artículo en Inglés | MEDLINE | ID: mdl-23426922

RESUMEN

Hepatitis C virus (HCV) protease inhibitor resistance-associated substitutions are selected during triple-therapy breakthrough. This multicenter quality control study evaluated the expertise of 23 French laboratories in HCV protease inhibitor resistance genotyping. A panel of 12 well-defined blinded samples comprising two wild-type HCV strains, nine transcripts from synthetic NS3 mutant samples or from clinical strains, and one HCV RNA-negative sample was provided to the participating laboratories. The results showed that any laboratory with expertise in sequencing techniques should be able to provide reliable HCV protease inhibitor resistance genotyping. Only a 0.7% error rate was reported for the amino acid sites studied. The accuracy of substitution identification ranged from 75% to 100%, depending on the laboratory. Incorrect results were mainly related to the methodology used. The results could be improved by changing the primers and modifying the process in order to avoid cross-contamination. This study underlines the value of quality control programs for viral resistance genotyping, which is required prior to launching observational collaborative multicenter studies on HCV resistance to direct-acting antiviral agents.


Asunto(s)
Antivirales/farmacología , Farmacorresistencia Viral/genética , Hepacivirus/efectos de los fármacos , Hepacivirus/genética , Inhibidores de Proteasas/farmacología , Proteínas no Estructurales Virales/genética , Secuencia de Aminoácidos , Antivirales/química , Secuencia de Bases , Genotipo , Hepacivirus/enzimología , Mutación , Inhibidores de Proteasas/química , Control de Calidad , Análisis de Secuencia de ADN
3.
J Clin Microbiol ; 50(4): 1384-9, 2012 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-22238432

RESUMEN

The automation of DNA extraction and the use of commercial quantitative real-time PCR assays could help obtain more reliable results for the quantification of Epstein-Barr virus DNA loads (EBV VL). This study compared two automated extraction platforms and two commercial PCRs for measurement of EBV VL in 10 EBV specimens from Quality Control for Molecular Diagnostics (QCMD) and in 200 whole-blood (WB) specimens from transplant (n = 137) and nontransplant (n = 63) patients. The WB specimens were extracted using the QIAcube or MagNA Pure instrument; VL were quantified with the EBV R-gene quantification kit (Argene) or the artus EBV RG PCR kit (Qiagen) on the Rotor-Gene 6000 real-time analyzer; and the results were compared with those of a laboratory-developed PCR. DNA was extracted from the QCMD specimens by use of the QIAamp DNA minikit and was quantified by the three PCR assays. The extraction platforms and the PCR assays showed good correlation (R, >0.9; P, <0.0001), but as many as 10% discordant results were observed, mostly for low viral loads (<3 log(10) copies/ml), and standard deviations reached as high as 0.49 log(10) copy/ml. In WB but not in QCMD samples, Argene PCR tended to give higher VL values than artus PCR or the laboratory-developed PCR (mean difference for the 200 WB VL, -0.42 or -0.36, respectively). In conclusion, the two automated extraction platforms and the two PCRs provided reliable and comparable VL results, but differences greater than 0.5 log(10) copy/ml remained between the two commercial PCRs after common DNA extraction.


Asunto(s)
ADN Viral/sangre , ADN Viral/aislamiento & purificación , Infecciones por Virus de Epstein-Barr/sangre , Herpesvirus Humano 4/genética , Reacción en Cadena en Tiempo Real de la Polimerasa , Carga Viral/métodos , Automatización de Laboratorios , Infecciones por Virus de Epstein-Barr/diagnóstico , Infecciones por Virus de Epstein-Barr/virología , Trasplante de Células Madre Hematopoyéticas , Herpesvirus Humano 4/fisiología , Humanos , Trasplante de Órganos , Juego de Reactivos para Diagnóstico , Reacción en Cadena en Tiempo Real de la Polimerasa/normas , Estándares de Referencia , Estadísticas no Paramétricas
4.
Lung Cancer ; 116: 15-24, 2018 02.
Artículo en Inglés | MEDLINE | ID: mdl-29413046

RESUMEN

OBJECTIVES: The aim of the present study was firstly to assess in a clinical setting the yields of an amplicon-based parallel RNA sequencing (RNA-seq) assay for ALK fusion transcript variants detection in comparison with immunohistochemistry (IHC) and fluorescent in-situ hybridization (FISH) in a selected population of ALK-positive and ALK-negative non-small cell lung cancer (NSCLC) cases, and secondly to evaluate the impact of the ALK variant on crizotinib efficacy. MATERIALS AND METHODS: The cohort used for the assessment of the RNA-seq assay comprised 53 samples initially diagnosed as being ALK-positive based on the results obtained by IHC and/or FISH, and 23 ALK-negative samples. A distinction was made between 'truly' IHC/FISH positive or 'truly' IHC/FISH negative samples, and those for which the IHC and/or FISH were equivocal (IHC) or borderline-positive (FISH). RESULTS: On the overall population, RNA-seq sensitivity (Se) and specificity (Spe) were of 80% and 100%, respectively when IHC and FISH were combined. For the 31 'truly positive' samples, Se and Spe of 100% were reached. An ALK status could be assigned by RNA-seq in 10/10 of the equivocal and/or borderline-positive IHC/FISH cases, 2/7 IHC/FISH discordant cases. When crizotinib efficacy was evaluated according to the type of ALK variant, better clinical outcomes were observed in crizotinib-treated patients with EML4-ALK v1/v2/others variants compared to v3a/b variants. CONCLUSION: RNA-seq detects ALK rearrangements with a high sensitivity and specificity using only 10 ng of RNA. It appears to be a promising rescue technique for non-clear-cut IHC/FISH cases and also offers a unique opportunity to identify ALK fusion variants and evaluate their predictive value for ALK inhibitors efficacy.


Asunto(s)
Quinasa de Linfoma Anaplásico/genética , Carcinoma de Pulmón de Células no Pequeñas/genética , Crizotinib/farmacología , Neoplasias Pulmonares/genética , Proteínas de Fusión Oncogénica/genética , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma de Pulmón de Células no Pequeñas/tratamiento farmacológico , Carcinoma de Pulmón de Células no Pequeñas/enzimología , Femenino , Amplificación de Genes , Humanos , Inmunohistoquímica , Hibridación Fluorescente in Situ , Neoplasias Pulmonares/tratamiento farmacológico , Neoplasias Pulmonares/enzimología , Masculino , Persona de Mediana Edad , ARN Neoplásico/genética , Análisis de Secuencia de ARN/métodos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA