Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur Radiol ; 27(4): 1733-1739, 2017 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27507304

RESUMEN

OBJECTIVES: To investigate whether compression of the superior mesenteric vein (SMV) on computed tomography (CT) can serve as a valid sign of internal herniation (IH) in patients with antecolic laparoscopic Roux-en-Y gastric bypass (LRYGBP). MATERIALS AND METHODS: With institutional review board approval, we performed a retrospective analysis of 41 patients with antecolic LRYGBP referred for acute CT of the abdomen with suspicion of IH or another cause of acute abdomen. CT scans were randomly reviewed for signs of IH by two radiologists in a blinded manner, and the findings were correlated with the results of the patients' bariatric workup. Sensitivity, specificity, and inter-observer agreement were calculated for each sign. RESULTS: Five patients were classified as having intermittent IH and were excluded. Eighteen patients were found to have IH at laparoscopy and served as the study group; 18 patients served as the control group. SMV compression had the best sensitivity (67 % for both reviewers) and inter-observer agreement (kappa = 0.82) of all investigated signs. The swirl sign showed a lower sensitivity (39 and 50 % respectively) and kappa (0.37). CONCLUSION: SMV compression is a reliable sign of IH in patients with antecolic LRYGBP. KEY POINTS: • CT can help detect internal herniation after laparoscopic Roux-en-Y gastric bypass. • Compression of the superior mesenteric vein is a sign of internal herniation. • This sign has a high inter-observer-agreement. • A diagnosis of internal herniation can be made with greater confidence.


Asunto(s)
Derivación Gástrica/efectos adversos , Hernia Abdominal/etiología , Venas Mesentéricas/diagnóstico por imagen , Síndromes de Compresión Nerviosa/etiología , Abdomen Agudo/etiología , Cavidad Abdominal , Enfermedad Aguda , Adulto , Anciano , Femenino , Hernia Abdominal/diagnóstico por imagen , Humanos , Laparoscopía , Masculino , Persona de Mediana Edad , Síndromes de Compresión Nerviosa/diagnóstico por imagen , Obesidad Mórbida/cirugía , Variaciones Dependientes del Observador , Examen Físico , Presión , Distribución Aleatoria , Estudios Retrospectivos , Sensibilidad y Especificidad , Método Simple Ciego , Tomografía Computarizada por Rayos X/métodos , Adulto Joven
2.
Artif Organs ; 39(7): 635-9, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25865505

RESUMEN

To evaluate the feasibility of implementing a cardiac assist system in a nonuniversity hospital we analyzed 18 consecutive patients treated with venoarterial membrane oxygenation. The system was used electively in 5/18 (27.8%) patients during high-risk interventions. Thirteen patients (72.2%) were treated in emergency situations. The extracorporal system could be initiated successfully in all patients. Periprocedural complications were hemolysis in 3/18 (16.7%), disseminated intravascular coagulation in 2/18 (11.1%), cerebral ischemia in 1/18 (5.6%), and local infection in 2/18 (11.1%) patients. None of these led to a discontinuation of the therapy. All electively treated patients were successfully weaned from the extracorporeal system. In 9/13 (69.2%) emergency patients the system was removed successfully. The 60-day survival rate of the emergency patients was 53.8% (7/13). Our experience confirms that an innovative extracorporeal circulatory support system can be implemented in a nonuniversity hospital at a tolerable risk and a low complication and high procedural success rate.


Asunto(s)
Oxigenación por Membrana Extracorpórea/instrumentación , Choque Cardiogénico/cirugía , Anciano , Urgencias Médicas , Diseño de Equipo , Oxigenación por Membrana Extracorpórea/efectos adversos , Femenino , Hemodinámica , Hemólisis , Hospitales , Humanos , Masculino , Oxigenadores de Membrana/efectos adversos , Choque Cardiogénico/complicaciones , Tasa de Supervivencia
3.
Knee Surg Sports Traumatol Arthrosc ; 23(11): 3398-406, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25038882

RESUMEN

PURPOSE: A clinically applicable and accurate method for measuring Achilles tendon length is needed to investigate the influence of elongation of the Achilles tendon after acute rupture. The purpose of this study was to develop and validate an ultrasonographic (US) length measurement of the Achilles tendon-aponeurosis complex. METHODS: Both legs of 19 non-injured subjects were examined by magnetic resonance imaging (MRI) and US. The length from calcaneus to the medial head of m. Gastrocnemius was measured by three independent US examiners. Repeated US measurements were performed and compared to MRI measurements. Intra-rater and inter-rater reliability and the agreement between MRI and US were determined. Data were evaluated using the intraclass correlation coefficient (ICC), the standard error of the measurement (SEM) and the minimal detectable change (MDC). RESULTS: Intra-rater reliability of US assessment showed no significant differences between test days: ICC 0.96, SEM 4 mm and MDC 10 mm. Inter-rater reliability showed a systematic difference between US observers of 2-5 mm (p = 0.001-0.036); ICC 0.97, SEM 3 mm and MDC 9 mm. MRI measurements were on average 4 mm longer than US (p = 0.001). CONCLUSION: The novel ultrasound measurement showed good reliability and accuracy. For comparison between groups of non-injured subjects differences of more than 4 mm can be detected. For repeated assessment of individual subjects differences of more than 10 mm can be detected. The measurement needs to be further assessed in the setting of acute Achilles tendon rupture. CLINICAL RELEVANCE: This new ultrasound measurement might allow for length measurement of ruptured Achilles tendons in the acute and chronic state after rupture. LEVEL OF EVIDENCE: II.


Asunto(s)
Tendón Calcáneo/diagnóstico por imagen , Tendón Calcáneo/anatomía & histología , Adulto , Puntos Anatómicos de Referencia , Humanos , Imagen por Resonancia Magnética , Persona de Mediana Edad , Reproducibilidad de los Resultados , Ultrasonografía
7.
Ugeskr Laeger ; 185(50)2023 12 11.
Artículo en Danés | MEDLINE | ID: mdl-38084625

RESUMEN

Introduction Imaging experience made us suspect an overrepresentation of ponytails in riders admitted as polytrauma after falling from their horse. Methods In a single-centre case-control study conducted over three months, we reviewed the records of all admitted polytraumatised patients for trauma mechanism and presence of ponytail on CT. Cerebral CTs were reviewed in the three standard imaging planes using a bone or lung window. Ponytail was diagnosed if most or all of the hair on the head was gathered and secured at the back of the head with a hair tie. Data were analysed with Fisher's exact test. Results Seven female riders (mean age 22 years) were admitted after falling from their horse (study group); six of these riders wore a ponytail. No male riders were admitted. Therefore, only female polytraumatised patients having suffered any other trauma were selected as controls. The control group consisted of 13 patients (mean age 33,5 years), two of whom wore a ponytail. In three controls, all without ponytails, the trauma also had been related to a horse. Thus, horses were involved in 50% of the traumas included in this study. Ponytail was found more frequently in riders admitted after falling from their horse, p less-than 0,005. Conclusion Having an almost circumferential vision, horses may be scared by the sideways swaying of a ponytail worn by their own rider. In riders, ponytails can trigger a sensation of tightness or even headache which may impair focus. Thus, while female riders most likely wear ponytails for practicality, ponytails may increase the risk of accident by affecting rider and horse. Further studies are required to determine if the observed association between ponytails and trauma is causal. Funding none. Trial registration not applicable.


Asunto(s)
Traumatismos en Atletas , Cabello , Caballos , Traumatismo Múltiple , Animales , Femenino , Humanos , Adulto Joven , Estudios de Casos y Controles , Cefalea/etiología , Caballos/fisiología , Incidencia , Traumatismo Múltiple/etiología , Traumatismos en Atletas/etiología
8.
Clin Res Cardiol ; 110(1): 12-20, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32296971

RESUMEN

OBJECTIVES: Chronic kidney disease (CKD) is associated with an increased complication rate after cardiac interventions. Although CKD has a high prevalence among atrial fibrillation patients, the impact of CKD on periprocedural complications and the outcome after an interventional left atrial appendage closure (LAAC) is unclear. The present study, therefore, aimed to investigate whether CKD influences the procedure's effectiveness and safety. METHODS: LAARGE is a prospective, non-randomised registry. LAAC was conducted with different standard commercial devices, and the follow-up period was one year. CKD was defined by an eGFR < 60 mL/min/1.73 m2, and subgroups were further analysed (i.e. eGFR < 15, 15-29, and 30-59 mL/min/1.73 m2, respectively). RESULTS: Two hundred ninety-nine of 623 patients (48.0%) revealed a CKD. The prevalence of cardiovascular comorbidity, CHA2DS2-VASc score (4.9 vs. 4.2), and HAS-BLED score (4.3 vs. 3.5) was significantly higher in CKD patients (each p < 0.001). Implantation success was similarly high across all GFR groups (97.9%). Periprocedural MACCE (0.7 vs. 0.3%), and other major complications (4.7 vs. 3.7%) were comparably infrequent. Survival free of stroke was significantly lower among CKD patients within 1 year (82.0 vs. 93.0%; p < 0.001; consistent after adjustment for confounding factors), without significant accentuation in advanced CKD (i.e. eGFR < 30 mL/min/1.73 m2; p > 0.05 vs. eGFR 30-59 mL/min/1.73 m2). Non-fatal strokes were absolutely infrequent during follow-up (0 vs. 1.1%). Severe non-fatal bleedings were observed only among CKD patients (1.4 vs. 0%; p = 0.021). CONCLUSIONS: Despite an increased cardiovascular risk profile of CKD patients, device implantation was safe, and LAAC was associated with effective stroke prevention across all CKD stages.


Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Procedimientos Quirúrgicos Cardíacos/métodos , Sistema de Registros , Insuficiencia Renal Crónica/complicaciones , Dispositivo Oclusor Septal , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/complicaciones , Femenino , Estudios de Seguimiento , Alemania , Tasa de Filtración Glomerular/fisiología , Humanos , Masculino , Estudios Prospectivos , Insuficiencia Renal Crónica/fisiopatología , Resultado del Tratamiento
9.
Am J Cardiol ; 136: 81-86, 2020 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-32946860

RESUMEN

Left atrial appendage closure (LAAC) is an alternative to oral anticoagulation therapy in patients with non-valvular atrial fibrillation for the prevention of embolic stroke and systemic embolism. Although elderly patients (>75 years) have both higher ischemic and bleeding risk as compared with younger patients, they benefit from optimal anticoagulation. The subanalysis aimed to assess the indications, the safety, efficacy, and 1-year outcomes of interventional LAAC in elderly patients (≥ 75 years) compared with younger (< 75 years) patients in clinical practice. We analyzed data from the prospective Left-Atrium-Appendage Occluder Registry Germany. A total of 638 patients were included in the registry, 402 (63%) were aged ≥ 75 years. Compared with younger subjects, patients aged ≥75 were more likely to have higher CHA2DS2-VASC and HAS-BLED scores. Procedural success rate was high und similar in both groups (97.6%). Periprocedural adverse events were not statistically significant in groups (11.9% in <75 years vs 12.9% in ≥75 years; p = 0.80). At 1 year follow-up, all-cause mortality was higher in patients aged ≥75 compared withwith younger group (13.0% vs 7.8 %,p = 0.04), mainly due to non-cardiovascular causes (10.6% vs 6.0%). No significant differences in major bleeding, stroke, systemic embolism were observed. In conclusion, LAAC is feasible and safe in patients with AF at high stroke risk and with contraindications for OAC and should be considered as candidates for LAA closure. Elderly patients often present these characteristics and could benefit from this novel therapy.


Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Dispositivo Oclusor Septal , Factores de Edad , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Alemania , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sistema de Registros , Factores de Tiempo , Resultado del Tratamiento
10.
Acta Otolaryngol ; 139(3): 304-308, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30794032

RESUMEN

BACKGROUND: Clinical practice made us suspect that vocal cord palsy (VCP) can be associated with extracranial internal carotid artery (ICA) tortuosity. OBJECTIVES: To find evidence for a causative relation between ICA tortuosity and VCP. METHODS: This single-center, retrospective study comprised 66 patients with VCP. A total of 45 patients without VCP served as control group. Patient charts were reviewed for etiology and side of VCP. CT scans were reviewed independently by two radiologists for imprint in the jugular vein (JV) caused by a tortuous ICA, considered an indirect sign of potential vagus nerve affection. RESULTS: A total of 33 patients had idiopathic VCP. ICA tortuosity causing a JV imprint with >10% JV lumen reduction was found more frequently on the paretic sides of patients with idiopathic VCP (15-24%) than in controls (3-9%), with p<.05 for observer 2 and p=.07 for observer 1. In patients with idiopathic VCP and JV imprint with >10% JV lumen reduction on one or both sides (n = 9), both observers found JV imprint with >10% JV lumen reduction more frequently on the side of VCP (p<.05). CONCLUSIONS: ICA tortuosity causing a JV imprint may be the cause of VCP in some of the cases of VCP currently regarded as idiopathic.


Asunto(s)
Arteria Carótida Interna/anatomía & histología , Parálisis de los Pliegues Vocales/etiología , Adulto , Anciano , Anciano de 80 o más Años , Variación Anatómica , Femenino , Humanos , Venas Yugulares/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Nervio Vago/fisiología , Adulto Joven
11.
Dan Med J ; 65(3)2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29510804

RESUMEN

INTRODUCTION: Valid length measurements of the different segments of the Achilles tendon are needed in order to investigate if differential elongation of the Achilles tendon takes place after rupture. The purpose of this paper was to present data concerning the accuracy and reliability of an ultrasound measurement of the free part of the Achilles tendon. METHODS: Both legs of 19 non-injured subjects were examined by magnetic resonance imagining (MRI) and ultrasound. The length from the distal tip of the soleus muscle to the tendon insertion on the calcaneus was measured by three independent ultrasound examiners. Repeated ultrasound measurements were performed and compared with MRI measurements. Intra-rater and inter-rater reliability and the agreement between MRI and ultrasound were determined. Data were evaluated using the intraclass correlation coefficient (ICC), the standard error of the measurement (SEM) and the minimal detectable change (MDC). RESULTS: The measurement showed excellent intra-rater reliability (ICC = 0.94 (95% confidence interval (CI): 0.91-0.96), SEM = 5 mm and MDC = 13 mm) and inter-rater reliability (ICC = 0.96 (95% CI: 0.93-0.97), SEM = 4 mm and MDC = 11 mm). On average, ultrasound measurements exceeded the MRI measurements by 2 mm (non-significant), resulting in a measurement error of 5%. CONCLUSIONS: The ultrasound measurement of the free part of the Achilles tendon showed good reliability and accuracy. For comparison between groups of non-injured subjects, differences of > 5 mm can be detected. For repeated assessment of individual subject differences ≥ 13 mm can be detected. FUNDING: none. TRIAL REGISTRATION: Institutional Review Board of Zealand, Denmark, Ref. no: SJ-318.


Asunto(s)
Tendón Calcáneo/anatomía & histología , Tendón Calcáneo/diagnóstico por imagen , Ultrasonografía , Adulto , Dinamarca , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Traumatismos de los Tendones/diagnóstico por imagen
12.
EuroIntervention ; 14(2): 151-157, 2018 06 20.
Artículo en Inglés | MEDLINE | ID: mdl-29508766

RESUMEN

AIMS: Interventional left atrial appendage closure (LAAC) is an emerging alternative to oral anticoagulation (OAC) for stroke prevention in atrial fibrillation (AF) in concomitance with a contraindication for standard OAC. This sub-analysis of the LAARGE registry aimed to investigate differences between different LAA morphologies in a real-world setting. METHODS AND RESULTS: This prospective, multicentre, observational registry included 562 patients from 37 centres with ineligibility for long-term OAC between April 2014 and January 2016. Baseline characteristics, indications, procedural data and complications were registered according to each LAA morphology (i.e., chicken wing, cauliflower, windsock, cactus and atypical morphologies). Implantation success was high across the four typical anatomies (≥97.5%, p=n.s.); only atypical anatomies exhibited a lower success rate (94%). The cactus-shaped LAA was linked to a trend indicating a shorter fluoroscopy time, while the atypical LAA was linked to a significantly prolonged fluoroscopy time (p=0.089 and p=0.025 versus the overall mean, respectively). Periprocedural and intra-hospital complications were generally rare, with no differences among the different morphologies (p=n.s.). CONCLUSIONS: Procedural success as well as the complication rates of LAAC were not different among the four typical LAA morphologies. A lower implantation success rate was only obvious in patients with atypical LAA morphologies.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Accidente Cerebrovascular , Humanos , Estudios Prospectivos , Sistema de Registros , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA