Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Catheter Cardiovasc Interv ; 99(3): 746-753, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34468076

RESUMEN

OBJECTIVES: To validate QFR using 4-F diagnostic catheters compared to using 6-F guiding catheters, with conventional guidewire-based FFR as the reference standard, using independent core laboratory analysis. BACKGROUND: Quantitative Flow Ratio (QFR) allows Fractional Flow Reserve (FFR) calculation based on the coronary angiogram, using 5- or 6-French (F) catheters. However, the use of 4-F diagnostic catheters to perform coronary angiography is currently routine in some centers. METHODS: We included all consecutive patients with stable coronary artery disease and indicated for physiological assessment. QFR was performed using a 4-F diagnostic catheter, then QFR was performed using a 6-F guiding catheter while conventional FFR was measured using a pressure guidewire. Angiograms were sent to two separate core laboratories. RESULTS: One hundred lesions in 67 consecutive patients with QFR performed using 4-F and 6-F catheters, and with conventional FFR, were included. Pearson's correlation coefficient was for QFR 4-F vs. FFR 0.91 [0.87-0.94], for QFR 6-F vs. FFR 0.90 [0.86-0.94], and for QFR 4-F vs. QFR 6-F 0.93 [0.90-0.95]. Receiver-operator characteristic curves (ROC) comparing the ability to predict an FFR value above or below 0.80 with QFR 4-F and 6-F were generated. The area under the ROC curve (AUC) vs. FFR was 0.972 [0.95-0.99] for QFR 4-F and 0.970 [0.94-0.99] for QFR 6-F. CONCLUSIONS: Our study demonstrated the feasibility of performing QFR analysis from angiograms obtained by 4-F catheters, and showed a good correlation with QFR performed using 6-F catheters as well as with conventional FFR performed using a pressure guidewire.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Catéteres , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/terapia , Vasos Coronarios , Reserva del Flujo Fraccional Miocárdico/fisiología , Humanos , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
2.
Catheter Cardiovasc Interv ; 99(3): 593-600, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34241947

RESUMEN

BACKGROUND: In patients at high bleeding risk (HBR), the LEADERS FREE (LF) trial established the safety and efficacy of a polymer-free drug coated (Biolimus-A9) stainless steel stent (SS-DCS) with 30 days of dual antiplatelet treatment (DAPT). In LEADERS FREE III, we studied a new cobalt-chromium thin-strut stent (CoCr-DCS) in HBR patients. METHODS: The CoCr-DCS shares all of the design features of the SS-DCS but has a CoCr stent platform with strut thickness of 84-88 µm. The primary safety endpoint was a composite of cardiac death, myocardial infarction (MI), and definite/probable stent thrombosis. The primary efficacy endpoint was clinically indicated target lesion revascularization. Outcomes were compared to those of LF (non-inferiority to SS-DCS for safety and superiority to SS-BMS for efficacy). Additional propensity-matched comparisons were performed to account for baseline differences. RESULTS: We recruited 401 HBR patients using identical criteria to the LF trial. At 1 year, the primary safety endpoint was reached by 31/401 (8.0%) of patients treated with the CoCr-DCS versus 35/401 (8.9%) for the propensity-matched cohort (HR: 0.89, [0.55-1.44], p < 0.001 for non-inferiority, 0.62 for superiority). The efficacy endpoint was reached by 16/401 (4.2%) of CoCr-DCS patients versus 41/401 (10.6%) in the propensity-matched cohort (HR: 0.4 [0.2:0.7]) (p = 0.007 for superiority). There was no statistical difference between CoCr-DCS and SS-DCS in terms of efficacy (HR: 1.46 [0.68-3.15], p = 0.33). CONCLUSIONS: The new thin-strut CoCr-DCS proved non-inferior to the SS-DCS for safety, and superior to the BMS for efficacy in HBR patients treated with 30 days of DAPT.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/etiología , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos/efectos adversos , Humanos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Polímeros , Diseño de Prótesis , Factores de Riesgo , Stents/efectos adversos , Resultado del Tratamiento
3.
Catheter Cardiovasc Interv ; 98(1): 45-54, 2021 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-32548891

RESUMEN

BACKGROUND: The Cobra PzF coronary stent is cobalt chromium with flat thin struts, nano-coated with Polyzene-F that enhance rapid reendothelialization and reduce the risk of stent thrombosis and restenosis. It is designed to overcome shortfalls of BMS and DES in patients requiring short DAPT duration. AIMS: To report procedural and 1-year clinical outcomes following Cobra PzF stent implantation in routine practice PCI. METHODS: e-Cobra registry is a multicenter prospective study to evaluate Cobra PzF stent in routine practice in patients deemed appropriate for short DAPT after PCI. The primary endpoint was MACE rate at 12 months (Cardiac death, MI, TLR). The secondary endpoint was definite stent thrombosis at 12 months. RESULTS: Among 940 patients (72% men, 72.8 ± 13.4 years) with multiple co-morbidities, 47% had acute coronary syndromes, and 62% were defined as high bleeding risk. A total of 1,229 lesions were treated with 1,314 stents. 36% of patients had lesion type B2 or C classification. Angiographic success was achieved in all cases. One-year follow-up was available for 97% of patients. The primary endpoint occurred in 9.0% of patients, including cardiac death 3.7%, MI 4.8%, and TLR 4.3%. Definite stent thrombosis occurred in six out of 915 (0.7%). CONCLUSION: The Cobra PzF stent was safe and effective in routine practice patients and seems feasible in situations when short DAPT or Mono Antiplatelet Therapy (MAPT) is needed. One-year follow-up was associated with satisfactory clinical outcomes and validate previously reported data.


Asunto(s)
Intervención Coronaria Percutánea , Stents , Anciano , Anciano de 80 o más Años , Materiales Biocompatibles Revestidos , Angiografía Coronaria , Reestenosis Coronaria/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Diseño de Prótesis , Stents/efectos adversos , Trombosis/etiología , Resultado del Tratamiento
4.
Catheter Cardiovasc Interv ; 98(3): E388-E394, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33913606

RESUMEN

OBJECTIVES: We sought to characterize the hemodynamic impact of mild coronary artery disease (CAD) using quantitative flow ratio (QFR, an angiography-derived fractional flow reserve [FFR]) in a population of patients with only non-significant CAD at baseline that subsequently experienced a myocardial infarction (MI). BACKGROUND: The discriminatory value of FFR in patients with mild CAD remains imperfect. METHODS: We retrospectively included patients who underwent invasive coronary angiography for an MI, in whom another angiogram had been performed within the previous 5 years. Three-dimensional quantitative coronary angiography, QFR, and lesion length analysis were conducted on lesions responsible for the MI (future culprit lesions, [FCL]) as well as on control lesions (non-culprit lesions, [NCL]). RESULTS: Eighty-three FCL and 117 NCL were analyzed in 83 patients: FCL were more severe (median % diameter of stenosis [DS] 39.1% [29.8; 45.7] vs. 29.8% [25.0; 37.2], p < .001), had lower QFR values (0.94 [0.86; 0.98] vs. 0.98 [0.96; 1.00], p < .001) and tended to be longer (15.2 mm [10.0; 27.3] vs. 12.7 mm [9.3; 22.4], p = .070) than NCL. In lesions with an interval < 2 years between baseline angiography and MI, the difference in QFR was more pronounced compared to the lesions with a longer interval (FCL: 0.92 [0.85; 0.97] vs. NCL: 0.98 [0.94; 1.00], p < .001 and FCL: 0.96 [0.88; 1.00] vs. NCL: 0.98 [0.96;1.00], p = .006 respectively) CONCLUSION: Mild coronary stenoses that are subsequently responsible for an MI (FCL) exhibit a higher DS and lower QFR years before the event. Furthermore, FCL with a lower QFR at baseline appear to lead earlier to MI.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Hemodinámica , Humanos , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
5.
Am Heart J ; 221: 148-154, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31924299

RESUMEN

BACKGROUND: Results of clinical trials are often criticized by low inclusion rate and potential sampling bias in patient recruitment. The aim of this validation registry is to evaluate how far an all-comers design in the context of clinical research can ensure the representation of the true all-comers population. METHODS: This validation registry is a prospective international multicentre registry, conducted at 10 out of the total 21 centers, participating in TARGET-AC (registered under NCT02520180). During a predefined four-week period data were recorded prospectively on all PCIs performed in the participating centers, whether or not patients were enrolled in TARGET-AC. Data were collected on patient demographics, angiographic lesion- and procedural characteristics. For patients who were not enrolled in the study, operators were asked to declare the reason for not enrolling the patient, using a single-choice questionnaire. RESULTS: A total of 131 patients were enrolled in the TARGET-AC study during the investigated period (ER group), standing as 20% (range 4% and 54%) of all eligible cases per protocol. In the ER group more patients presented with stable angina (61% vs. 43%, respectively; P < .001). Whereas ST-elevation infarction was less common (5% vs. 26%, respectively; P < .001), there was no difference in non-ST elevation acute coronary syndrome (32% vs. 27%, respectively; P = .248). Risk factors and comorbidities did not show any difference between the ER and the non-enrolled (NER) groups, except for greater rate of significant valvular disease in the NER group (12% vs 19%, respectively; P = .037). The NER group presented more thrombotic stenoses than the ER group (20% vs 12%, respectively; P = .040). No difference was found in any other investigated angiographic parameters, like target vessels, bifurcation lesion, severe calcification or chronic total occlusions. Admission during regular working hours and availability of study nurse were associated with markedly higher recruitment rate. CONCLUSION: Results suggest that TARGET AC was outbalanced for stable patients over primary PCIs as compared to real world. However in terms of risk factors and comorbidities the trial managed to represent the collective of real world clinical practice. Fairly representative cases were included at an average inclusion-to-eligible rate of 20%.


Asunto(s)
Estenosis Coronaria/cirugía , Stents Liberadores de Fármacos , Selección de Paciente , Intervención Coronaria Percutánea , Sistema de Registros , Proyectos de Investigación , Síndrome Coronario Agudo/cirugía , Anciano , Angina Estable/cirugía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio sin Elevación del ST/cirugía , Estudios Prospectivos , Infarto del Miocardio con Elevación del ST/cirugía
6.
Catheter Cardiovasc Interv ; 96(2): E142-E148, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-31696618

RESUMEN

OBJECTIVES: To assess long-term safety and efficacy of the Xposition S self-apposing stent in the treatment of unprotected left main coronary artery (ULMCA) disease. BACKGROUND: Percutaneous intervention with stents has emerged as a valid alternative to surgical revascularization to treat ULMCA disease. Conventional balloon-expandable stents face technical challenges, particularly in large left main diameter requiring extensive optimization and side branch access in distal bifurcation. Xposition S allows for optimal apposition, bridging diameter differences, and allows expansion to vessel diameters up to 6.0 mm. METHODS: Between June 2016 and July 2017, 205 patients were enrolled in this international, prospective, multicenter registry. Patients with SYNTAX score ≥ 33 or recent STEMI were excluded. IVUS during procedure was performed in a prespecified subgroup of 50 patients. The primary clinical endpoint was 12 months Target lesion failure (TLF) and the primary efficacy endpoint was angiographic success. RESULTS: Distal left main bifurcation was involved in 92.7%, treated with provisional approach in most cases (79.4%). TLF rate at 12 months was 8.3%, which was defined as a composite of cardiac death (2.0%), target-vessel MI (2.9%), and TLR (5.4%). Most revascularizations occurred at SB ostium. IVUS analysis demonstrated optimal stent apposition with only one reported malapposition and promising poststenting minimal stent area measures. CONCLUSIONS: The TRUNC study confirms that Xposition S self-apposing stent is a valid and feasible option for the treatment of ULMCA disease. Such results were reached without the systematic need of stent optimisation techniques, focusing mainly on lesion treatment.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Stents Metálicos Autoexpandibles , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Europa (Continente) , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Método Simple Ciego , Factores de Tiempo , Resultado del Tratamiento
7.
Heart Vessels ; 35(1): 132-135, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31250129

RESUMEN

Coronary bifurcation revascularization needs to take account of the diameter differential between vessels and to limit side-branch obstruction (SBO). The self-apposing properties of the Xposition S™ stent (STENTYS, France) seem interesting in this regard. The present experimental fractal bench study determined the best provisional stenting technique using Xposition S™. Three sequential strategies were compared (n = 5/group): implantation alone, side-branch inflation (SBI), and re-POT (initial proximal optimization technique (POT) + SBI + final POT). 2D- and 3D-OCT analyses and micro-CT scan were performed to quantify the main mechanical results at each step. Of the three groups, SBI and re-POT provided better final results than implantation alone in terms of residual SBO (respectively, 24.6 ± 5.6% and 24.8 ± 5.0% vs. 46.5 ± 10.3%, p < 0.05) and malapposition (respectively, 0.9 ± 0.6% and 0.8 ± 0.4% vs. 3.8 ± 1.9%, p < 0.05). Unlike SBI, the two POTs of the re-POT sequence did not improve the final result. SBI, alone or as part of re-POT, systematically led to one connector breakage, whereas implantation alone maintained complete stent integrity (p < 0.05). In Xposition S™ implantation, SBI should be systematic, but not post-dilatation specifically dedicated to bifurcation stenting (i.e., POTs). However, global post-dilatation is still mandatory to prevent stent underexpansion due to untreated stenosis.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Fractales , Modelos Cardiovasculares , Stents , Ensayo de Materiales , Diseño de Prótesis , Tomografía de Coherencia Óptica , Microtomografía por Rayos X
8.
Lancet ; 392(10153): 1117-1126, 2018 09 29.
Artículo en Inglés | MEDLINE | ID: mdl-30190206

RESUMEN

BACKGROUND: The FIREHAWK is a drug-eluting stent with a fully biodegradable sirolimus-containing polymer coating localised to recessed abluminal grooves on the stent surface. We investigated clinical outcomes with this targeted, low-dose, biodegradable polymer, sirolimus-eluting stent compared with XIENCE durable polymer, everolimus-eluting stents in an all-comers population. METHODS: The TARGET All Comers study was a prospective, multicentre, open-label randomised non-inferiority trial done at 21 centres in ten European countries. Patients with symptomatic or asymptomatic coronary artery disease and objective evidence of myocardial ischaemia who qualified for percutaneous coronary intervention were randomised 1:1 to undergo implantation of a FIREHAWK or XIENCE. Randomisation was web-based, with random block allocation and stratification by centre and ST elevation myocardial infarction. Outcome assessors were masked to treatment allocation, but treating physicians and patients were not. The primary endpoint was target lesion failure at 12 months, a composite of cardiac death, target vessel myocardial infarction, or ischaemia-driven target lesion revascularisation. The control event rate for XIENCE was assumed to be 7%, the non-inferiority margin was 3.5%, and the primary analysis was in the intention-to-treat population, censoring patients who did not have either an event before 365 days or contact beyond 365 days. Late lumen loss was the primary endpoint of an angiographic substudy designed to investigate the non-inferiority of the FIREHAWK compared with the XIENCE stent. This trial is registered with ClinicalTrials.gov, number NCT02520180. FINDINGS: From Dec 17, 2015, to Oct 14, 2016, 1653 patients were randomly assigned to implantation of the FIREHAWK (n=823) or XIENCE (n=830). 65 patients in the FIREHAWK group and 66 in the XIENCE group had insufficient follow-up data and were excluded from the analyses. At 12 months, target lesion failure occurred in 46 (6·1%) of 758 patients in the FIREHAWK group and in 45 (5·9%) of 764 patients in the XIENCE group (difference 0·2%, 90% CI -1·9 to 2·2, pnon-inferiority=0·004, 95% CI -2·2 to 2·6, psuperiority=0·88). There were no differences in ischaemia-driven revascularisation or stent thrombosis rates at 12 months. 176 patients were included in the angiographic substudy, in which in-stent late lumen loss was 0·17 mm (SD 0·48) in the FIREHAWK group and 0·11 mm (0·52) in the XIENCE group (p=0·48), with an absolute difference of 0·05 mm (95% CI -0·09 to 0·18, pnon-inferiority=0·024). INTERPRETATION: In a broad all-comers population of patients requiring stent implantation for myocardial ischaemia, the FIREHAWK was non-inferior to the XIENCE as assessed with the primary endpoint of target lesion failure at 12 months and in-stent late lumen loss at 13 months. The FIREHAWK is a safe and effective alternative stent to treat patients with ischaemic coronary artery disease in clinical practice. FUNDING: Shanghai Microport Medical.


Asunto(s)
Implantes Absorbibles , Stents Liberadores de Fármacos , Inmunosupresores/administración & dosificación , Isquemia Miocárdica/cirugía , Sirolimus/administración & dosificación , Anciano , Estudios de Equivalencia como Asunto , Everolimus/administración & dosificación , Femenino , Humanos , Análisis de Intención de Tratar , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diseño de Prótesis , Resultado del Tratamiento
9.
Catheter Cardiovasc Interv ; 90(6): 890-897, 2017 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-28544186

RESUMEN

OBJECTIVES: The French Ebiomatrix registry aimed to confirm the results of the Leaders trial in an all-comer population in France. BACKGROUND: The Leaders trial showed the Biolimus-eluting-sent (BES) to be equivalent to the Cypher stent in terms of safety and efficacy at 1 year and superior regarding stent thrombosis after 1 year. METHODS: BES recipients were enrolled in 42 French centers with up to 24-month clinical follow up. RESULTS: 2365 patients were included. Mean age: 65.7 ±11.2 years, 76.1% males, 31.8% had diabetes, 36.5% ACS (28.7% non-ST-elevation MI and 7.8% with ST-elevation MI). 1.7 ± 1.0 stents/patient were implanted and procedural success was 99.5%. 12-month follow-up was completed in 94.3% patients and 24 months in 91.4%. MACCE rates at 12 and 24 months were 5.8% and 9% (all cause-death 1.5% and 2.2%; stent thrombosis definite/probable 0.4% and 0.6%), respectively. MACCE were not significantly higher in diabetic patients compared with non-diabetics but cardiac death was higher (1.6% vs. 0.6%, P = 0.01 at 1 year and 1.9% vs. 0.6, P = 0.005 at 2 years) as was stent thrombosis (0.9% vs. 0.2%, P = 0.009 and 1.2 vs. 0.3% P = 0.008). Compared with non-ACS patients, MACCE was significantly higher in the ACS subgroup (7.5% vs. 4.8%, P = 0.001 at 1 year and 10.3% vs.8.1%, P = 0.07 at 2 years). CONCLUSION: In this large real-world registry, the BES with biodegradable polymer showed excellent acute and mid-term outcomes with a 5.8% and 9% rate of MACCE at one and 2 years and a very low rate of stent thrombosis between 1 and 2 years (0.2%), thus demonstrating the replicability of the LEADERS trial in a registry population. © 2017 The Authors Catheterization and Cardiovascular Interventions Published by Wiley Periodicals, Inc.


Asunto(s)
Enfermedad de la Arteria Coronaria/cirugía , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/métodos , Complicaciones Posoperatorias/epidemiología , Sistema de Registros , Implantes Absorbibles , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico , Femenino , Estudios de Seguimiento , Francia/epidemiología , Humanos , Incidencia , Masculino , Estudios Prospectivos , Diseño de Prótesis , Factores de Riesgo , Tasa de Supervivencia/tendencias , Factores de Tiempo , Resultado del Tratamiento
10.
Cardiol J ; 31(1): 24-31, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-36896636

RESUMEN

BACKGROUND: Management of thrombus burden during primary percutaneous coronary intervention (pPCI) is a key-point, given the high risk of stent malapposition and/or thrombus embolization. These issues are especially important if pPCI involves a coronary bifurcation. Herein, a new experimental bifurcation bench model to analyze thrombus burden behavior was developed. METHODS: On a fractal left main bifurcation bench model, we generated standardized thrombus with human blood and tissue factor. Three provisional pPCI strategies were compared (n = 10/group): 1) balloon-expandable stent (BES), 2) BES completed by proximal optimizing technique (POT), and 3) nitinol self-apposing stent (SAS). The embolized distal thrombus after stent implantation was weighed. Stent apposition and thrombus trapped by the stent were quantified on 2D-OCT. To analyze final stent apposition, a new OCT acquisition was performed after pharmacological thrombolysis. RESULTS: Trapped thrombus was significantly greater with isolated BES than SAS or BES+POT (18.8 ± 5.8% vs. 10.3 ± 3.3% and 6.2 ± 2.1%, respectively; p < 0.05), and greater with SAS than BES+POT (p < 0.05). Isolated BES and SAS tended show less embolized thrombus than BES+POT (5.93 ± 4.32 mg and 5.05 ± 4.56 mg vs. 7.01 ± 4.32 mg, respectively; p = NS). Conversely, SAS and BES+POT ensured perfect final global apposition (0.4 ± 0.6% and 1.3 ± 1.3%, respectively, p = NS) compared to isolated BES (74.0 ± 7.6%, p < 0.05). CONCLUSIONS: This first experimental bench model of pPCI in a bifurcation quantified thrombus trapping and embolization. BES provided the best thrombus trapping, while SAS and BES+POT achieved better final stent apposition. These factors should be taken into account in selecting revascularization strategy.


Asunto(s)
Ácidos Alcanesulfónicos , Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Trombosis , Humanos , Diseño de Prótesis , Stents , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Trombosis/etiología , Resultado del Tratamiento , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía
11.
Int J Cardiol ; 397: 131632, 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-38048882

RESUMEN

BACKGROUND: Re-POT (proximal optimization technique (POT)) is a simple provisional sequential technique for percutaneous coronary bifurcation revascularization with better arterial geometry respect compared to classical techniques. Re-POT has demonstrated excellent mechanical and short-term clinical results. The multicenter CABRIOLET registry (NCT03550196) evaluate the long-term clinical benefit of the re-POT sequence in non-selected patients. METHODS: All consecutive patients presenting a coronary bifurcation lesion for which provisional stenting was indicated were included in 5 european centers. Re-POT strategy was systematically attempted. The primary endpoint was target lesion failure (TLF), comprising cardiac death, myocardial infarction, stent thrombosis and target lesion revascularization (TLR) at 12 months' follow-up. The secondary endpoints were the individual components of the primary endpoint, all-cause death, target vessel failure (TVF) and target vessel revascularization (TVR). Complex bifurcation was defined as Medina 0.1.1 or 1.1.1. RESULTS: A total of 500 patients aged 67.7 ± 11.7 years, 78.4% male, were included from 2015 to 2019, 174 of whom (34.8%) were considered having complex bifurcation lesions. Bifurcations involved the left main in 35.2% of cases. The full re-POT sequence was systematically performed in all cases. At 1 year, TLF was 2.0% (1.7% in complex vs. 2.1% in non-complex bifurcation; p = NS), and TLR was 1.6%, (1.1% vs. 1.8% respectively; p = NS). TVF and TVR rates were 3.2% and 2.8%. On multivariate analysis, only multivessel disease was predictive of TLF at 1 year (OR = 1.66 (1.09-2.53), p = 0.02). CONCLUSIONS: In this large prospective all-comer registry, provisional stenting with re-POT technique appeared safe and effective at 1 year, without anatomical bifurcation restriction.


Asunto(s)
Enfermedad de la Arteria Coronaria , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Masculino , Femenino , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/complicaciones , Estudios Prospectivos , Resultado del Tratamiento , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/métodos , Stents/efectos adversos , Sistema de Registros , Angiografía Coronaria/métodos
12.
Open Heart ; 11(1)2024 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-38890129

RESUMEN

BACKGROUND: For high bleeding-risk patients (HBR) undergoing percutaneous coronary intervention (PCI), the LEADERS FREE (LF) and LEADERS FREE II (LF II) trials established the safety and efficacy of a stainless steel polymer-free biolimus-coated stent (SS-BCS) with 30 days of dual antiplatelet treatment (DAPT). The LEADERS FREE III (LF III) trial investigated clinical outcomes after PCI with the next-generation cobalt-chromium thin-strut polymer-free biolimus-coated stent (CoCr-BCS) in HBR patients. AIMS: To report the final 3-year results of the LF III trial and compare them to LF II. METHODS: LF III was a prospective, multicentre, open-label single-arm study to evaluate the safety and efficacy of the CoCr-BCS stent. The primary safety endpoint was the composite of cardiac death (CD), myocardial infarction(MI) or definite/probable stent thrombosis (ST). The primary efficacy endpoint was clinically driven target lesion revascularisation (cd-TLR). We performed a propensity-matched comparison to the 3-year outcomes of LF II. RESULTS: After 3 years, CD/MI/ST had occurred in 57 patients (15%, 95% CI 11.8% to 19%) and cd-TLR in 23 (6.2%, 95% CI 4.1% to 9.2%) patients. In a propensity-matched comparison of patients treated with the CoCr-BCS versus the SS-BCS, there were similar rates of CD (6.6% vs 7.8%, p=0.50), MI (7.1% vs 8.3%, p=0.47) and definite/probable ST (1.1% vs 2%, HR 0.56, 95% CI 0.16 to 1.93, p=0.35). The rates of cd-TLR were 5.3% with CoCr-BCS versus 9.8% with SS-BCS (HR 0.54, 95% CI 0.31 to 0.96, p=0.03). CONCLUSION: LF III confirms the long-term safety and efficacy of the CoCr-BCS in HBR patients treated with 1 month of DAPT. TRIAL REGISTRATION NUMBER: NCT02843633, NCT03118895.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Diseño de Prótesis , Sirolimus , Humanos , Masculino , Estudios Prospectivos , Femenino , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/métodos , Intervención Coronaria Percutánea/efectos adversos , Sirolimus/análogos & derivados , Sirolimus/farmacología , Sirolimus/administración & dosificación , Resultado del Tratamiento , Enfermedad de la Arteria Coronaria/terapia , Enfermedad de la Arteria Coronaria/diagnóstico , Anciano , Factores de Tiempo , Persona de Mediana Edad , Estudios de Seguimiento , Inhibidores de Agregación Plaquetaria/uso terapéutico , Factores de Riesgo
13.
EuroIntervention ; 18(16): e1358-e1364, 2023 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-36648404

RESUMEN

Quantitative flow ratio (QFR) is a computation of fractional flow reserve (FFR) based on invasive coronary angiographic images. Calculating QFR is less invasive than measuring FFR and may be associated with lower costs. Current evidence supports the call for an adequately powered randomised comparison of QFR and FFR for the evaluation of intermediate coronary stenosis. The aim of the FAVOR III Europe Japan trial is to investigate if a QFR-based diagnostic strategy yields a non-inferior 12-month clinical outcome compared with a standard FFR-guided strategy in the evaluation of patients with intermediary coronary stenosis. FAVOR III Europe Japan is an investigator-initiated, randomised, clinical outcome, non-inferiority trial scheduled to randomise 2,000 patients with either 1) stable angina pectoris and intermediate coronary stenosis, or 2) indications for functional assessment of at least 1 non-culprit lesion after acute myocardial infarction. Up to 40 international centres will randomise patients to either a QFR-based or a standard FFR-based diagnostic strategy. The primary endpoint of major adverse cardiovascular events is a composite of all-cause mortality, any myocardial infarction, and any unplanned coronary revascularisation at 12 months. QFR could emerge as an adenosine- and wire-free alternative to FFR, making the functional evaluation of intermediary coronary stenosis less invasive and more cost-effective.


Asunto(s)
Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/cirugía , Vasos Coronarios , Europa (Continente) , Japón , Valor Predictivo de las Pruebas , Estudios Prospectivos , Índice de Severidad de la Enfermedad , Ensayos Clínicos Controlados Aleatorios como Asunto
14.
EuroIntervention ; 19(10): e844-e855, 2023 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-37860860

RESUMEN

BACKGROUND: In the prospective, multicentre, randomised TARGET All Comers study, percutaneous coronary intervention (PCI) with the FIREHAWK biodegradable-polymer sirolimus-eluting stent (BP-SES) was non-inferior to the durable-polymer everolimus-eluting stent (DP-EES) for the primary endpoint of target lesion failure (TLF) at 12 months. AIMS: We aimed to report the final study outcomes at 5 years. METHODS: Patients referred for PCI were randomised to receive either a BP-SES or DP-EES in a 1:1 ratio in 10 European countries. Randomisation was stratified by centre and ST-elevation myocardial infarction (STEMI) presentation, and clinical follow-up extended to 5 years. The primary endpoint was TLF (composite of cardiac death, target vessel myocardial infarction [MI], or ischaemia-driven target lesion revascularisation). Secondary endpoints included patient-oriented composite events (POCE; composite of all-cause death, all MI, or any revascularisation and its components). RESULTS: From December 2015 to October 2016, 1,653 patients were randomly assigned to the BP-SES or DP-EES groups, of which 93.8% completed 5-year clinical follow-up or were deceased. At 5 years, TLF occurred in 17.1% of the BP-SES group and in 16.3% of the DP-EES group (p=0.68). POCE occurred in 34.0% of the BP-SES group and 32.7% of the DP-EES group (p=0.58). Revascularisation was the most common POCE, occurring in 19.3% of patients receiving BP-SES and 19.2% receiving DP-EES, of which less than one-third was ischaemia-driven target lesion-related. In the landmark analysis, there were no differences in the rates of TLF and POCE between groups from 1 to 5 years, and these results were consistent across all subgroups. CONCLUSIONS: In an all-comers population requiring stent implantation for myocardial ischaemia, the BP-SES was non-inferior to the DP-EES for the primary endpoint of TLF at 12 months, and results were sustained at 5 years, confirming the long-term safety and efficacy of the FIREHAWK BP-SES.


Asunto(s)
Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Sirolimus , Stents Liberadores de Fármacos/efectos adversos , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Resultado del Tratamiento , Implantes Absorbibles , Everolimus , Infarto del Miocardio/etiología , Polímeros
15.
J Invasive Cardiol ; 34(4): E281-E285, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35302947

RESUMEN

OBJECTIVES: We aimed to validate whether quantitative flow ratio (QFR) analysis could be performed by both medical and paramedical certified users. Therefore, we compared QFR values with conventional guidewire-based fractional flow reserve (FFR) as the reference using core laboratory analysis. QFR allows FFR calculation based on the coronary angiogram. QFR analysis requires certified users with dedicated training and skills. However, the ability of medical and paramedical users to correctly analyze QFR remains unknown. METHODS: In a prospective, single-center study, we included all consecutive patients with stable coronary artery disease and indicated physiological assessment. QFR was performed and analyzed by 1 medical and 2 paramedical QFR users who were unaware of conventional pressure-guidewire FFR measurements. RESULTS: We included 67 consecutive patients and 100 lesions for assessment with QFR and FFR. Pearson's correlation coefficient of QFR performed by paramedical users compared with medical users was 0.89 (range, 0.83-0.92). A Bland-Altman analysis showed no significant bias (-0.0008). Receiver-operator characteristic curves were generated to compare the ability to predict an FFR value above or below 0.80 with QFR performed by paramedical vs medical users. When comparing FFR with QFR performed by paramedical and medical users, the values for area under the curve were 0.964 and 0.970, respectively. Intraclass correlation was 0.884. CONCLUSION: Our study showed a noticeable correlation between QFR analysis performed by QFR-certified paramedical and medical users, as compared with FFR. These data suggest that QFR analysis could be performed by certified paramedicals in order to reduce physician workload without impacting the quality of the obtained results.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Vasos Coronarios , Reserva del Flujo Fraccional Miocárdico/fisiología , Humanos , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad
16.
Cardiovasc Revasc Med ; 41: 76-80, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35045942

RESUMEN

BACKGROUND/PURPOSE: The COBRA Polyzene F™ NanoCoated Coronary Stent System (PzF coated stent) stent demonstrated favorable clinical outcomes at 9 months but late results have not been reported. We sought to assess the late safety and effectiveness of the PzF coated stent for treatment of de novo coronary artery lesions. METHODS: Patients with de novo coronary artery lesions meeting eligibility criteria were enrolled in a non-randomized, prospective clinical trial and followed for 5 years. The primary endpoint was target vessel failure (TVF, cardiac death, myocardial infarction [MI], or clinically-driven target vessel revascularization [TVR]) at 9 months. Secondary endpoints included major adverse clinical events (MACE, cardiac death, MI, or clinically driven TLR), clinically driven target lesion revascularization (TLR) and definite or probable stent thrombosis during 5-year follow-up. Endpoints at 5 years were analyzed as cumulative incidence accounting for competing risk of death. RESULTS: Of 296 enrolled patients, 290 (98%) were evaluable at 5 years. By 5 years, MACE had occurred in 61 (21.3%), cardiac death in 11 (4.2%), MI in 25 (8.6%), and TLR in 34 (12.0%) subjects. Between follow-up years 1 and 5, a first MACE occurred in 17 (6.2%), including 10 (4.0%) cardiac death, 4 (1.6%) MI, and 7 (2.9%) TLR events. There were no definite or probable stent thromboses. CONCLUSIONS: The PzF coated stent demonstrated continued safety and effectiveness through 5 years with low to very low incident rates of MACE, MI, TLR and stent thrombosis between 1 and 5 years after stent placement.


Asunto(s)
Enfermedad de la Arteria Coronaria , Infarto del Miocardio , Intervención Coronaria Percutánea , Trombosis , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/terapia , Muerte , Humanos , Infarto del Miocardio/complicaciones , Intervención Coronaria Percutánea/efectos adversos , Estudios Prospectivos , Diseño de Prótesis , Stents/efectos adversos , Trombosis/etiología , Resultado del Tratamiento
17.
Cardiovasc Revasc Med ; 34: 17-24, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-33608239

RESUMEN

BACKGROUND/PURPOSE: A coronary stent with thromboresistant and pro-healing properties such as the polymer polyzene F-coated (COBRA PzF) stent might safely allow for a very short duration of triple therapy in patients taking oral anticoagulation (OAC) who undergo coronary stenting. METHODS: The COBRA-REDUCE trial is a prospective, multinational, randomized, open-label, assessor-blinded trial. A total of 996 patients at high bleeding risk because of requirement for OAC (with a vitamin K antagonist or non-vitamin K antagonist for any indication) will be randomized at sites in the United States and Europe to treatment with the COBRA-PzF stent followed by very short duration (14 days) DAPT or a Food and Drug Administration (FDA)-approved new generation drug-eluting stent followed by guideline-recommended DAPT duration (3 or 6 months). Two co-primary endpoints will be tested at 6 months: a bleeding co-primary endpoint (bleeding academic research consortium [BARC] ≥2 bleeding beyond 14 days or after hospital discharge, whichever is later [superiority hypothesis]) and a thrombo-embolic co-primary endpoint (the composite of all-cause death, myocardial infarction, definite/probable stent thrombosis or ischaemic stroke [non-inferiority hypothesis]). The trial is registered at clinicaltrials.gov (NCT02594501). CONCLUSION: The COBRA-REDUCE trial will determine whether coronary stenting with the COBRA PzF stent followed by 14 days of clopidogrel will reduce bleeding without increasing thrombo-embolic events compared with FDA-approved DES followed by 3-6 months clopidogrel in patients taking OAC and aspirin.


Asunto(s)
Isquemia Encefálica , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Accidente Cerebrovascular , Isquemia Encefálica/etiología , Quimioterapia Combinada , Humanos , Intervención Coronaria Percutánea/efectos adversos , Inhibidores de Agregación Plaquetaria/efectos adversos , Estudios Prospectivos , Stents , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/prevención & control , Resultado del Tratamiento
18.
Arch Cardiovasc Dis ; 115(10): 505-513, 2022 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-36123284

RESUMEN

BACKGROUND: Randomized trials comparing the first-generation absorb bioresorbable vascular scaffold (BVS) (Abbott Vascular, Santa Clara, CA, USA) with a drug-eluting stent showed a moderate but significant increase in the rate of 3-year major adverse cardiac events and scaffold thrombosis, followed by a decrease in adverse events after 3 years. AIM: The objective of this study was to assess the 5-year outcomes of patients treated with at least one absorb BVS and included in the FRANCE ABSORB registry. METHODS: All patients treated in France with an absorb BVS were prospectively included in a large nationwide multicentre registry. The primary efficacy outcome was the occurrence of 5-year major adverse cardiac events. Secondary efficacy outcomes were the rates of 5-year target vessel revascularization and definite/probable scaffold thrombosis. RESULTS: Between September 2014 and April 2016, 2,070 patients were included in 86 centres (mean age 55±11 years; 80% men; 49% with acute coronary syndrome). The rates of 1-, 3- and 5-year major adverse cardiac events were 3.9%, 9.4% and 12.1%, respectively (including cardiac death in 2.5% and target vessel revascularization in 10.4%). By multivariable analysis, diabetes, oral anticoagulation, the use of multiple Absorb BVSs and the use of a 2.5mm diameter absorb BVS were associated with 5-year major adverse cardiac events. The rates of 1-, 3- and 5-year definite/probable scaffold thrombosis were 1.5%, 3.1% and 3.6%, respectively. By multivariable analysis, older age, diabetes, anticoagulation at discharge and the use of a 2.5mm diameter absorb BVS were associated with 5-year scaffold thrombosis. CONCLUSIONS: Absorb BVS implantation was associated with low rates of 1-year major adverse cardiac events, which increased significantly at 3-year follow-up. There was a clear decrease in the rates of scaffold thrombosis and major adverse cardiac events after 3 years.


Asunto(s)
Enfermedad de la Arteria Coronaria , Diabetes Mellitus , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea , Masculino , Humanos , Adulto , Persona de Mediana Edad , Anciano , Femenino , Implantes Absorbibles , Everolimus , Resultado del Tratamiento , Diseño de Prótesis , Factores de Tiempo , Sistema de Registros , Anticoagulantes , Intervención Coronaria Percutánea/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía
19.
Arch Cardiovasc Dis ; 113(3): 199-208, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32008946

RESUMEN

The specific anatomy of coronary bifurcations makes them prime sites of atherogenesis and complicates revascularization. Account must be taken of the systematic difference in diameter between the 3 constituent vessels so as to minimize final side-branch ostium obstruction and maintain the law of conservation of flow, while respecting the bifurcation angles. Kissing balloon inflation (KBI) was long recommended, but never clearly demonstrated clinical benefit in single-stent provisional stenting. The detrimental proximal overstretch induced by simultaneous inflation of balloons, observed clinically and confirmed experimentally, probably explains this inefficacy. Advances in knowledge of bifurcation pathophysiology and experimental bench studies gradually led to the development of a new purely sequential technique, re-POT, without balloon juxtaposition, comprising 3 successive steps: (1) initial "proximal optimization technique" (POT), (2) side-branch opening, and (3) final POT. In contrast to KBI, re-POT has been progressively assessed from bench to first clinical study. The aim of the present review is to present the pathophysiological specificities of coronary bifurcations, and some explanations for the failure of KBI which led to the development of a new purely sequential coronary bifurcation provisional stenting strategy, based on re-POT.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios , Stents , Angioplastia Coronaria con Balón/efectos adversos , Animales , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/fisiopatología , Circulación Coronaria , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Hemodinámica , Humanos , Modelos Cardiovasculares , Resultado del Tratamiento
20.
Cardiovasc Revasc Med ; 21(6): 785-789, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-31780418

RESUMEN

AIMS: To report procedural and 1-year outcomes following COBRA PzF NCS implantation in a routine daily setting with high bleeding risk (HBR) patients treated with clopidogrel as mono antiplatelet therapy (MAPT). METHODS: This is a prospective, consecutive, observational study in HBR patients who underwent PCI with COBRA PzF NCS and treated with clopidogrel alone at discharge. The primary endpoint was definite stent thrombosis at one month. The secondary endpoint was MACE (Cardiac Death, myocardial infarction (MI), target lesion revascularization (TLR)) at 12 months. RESULTS: From October 2015 to December 2018, 77 patients with 120 lesions were enrolled and treated. Mean age was 78.7 ±â€¯8.89 years, 58.5% men and 18.2% had ACS. Patients included had a minimum of 2.0 inclusion LEADERS FREE criteria. Angiographic success was achieved in all cases. The primary endpoint occurred in 0%, no stent thrombosis was occurred. MACE at 12-months (available for 52 patients) was 3.8% including cardiac death 0%, MI 0% and TLR 3.8%. No severe bleeding events (BARC3-5) or stroke or late stent thrombosis were noted. CONCLUSION: Clopidogrel as MAPT after COBRA PzF NCS implantation in HBR patients is feasible and an attractive option. One-year follow-up was associated with excellent clinical outcomes and should be confirmed with large randomised study. CONDENSED ABSTRACT: This is prospective registry of high bleeding risk patients treated with the COBRA PzF NCS and MAPT at discharge. The primary end point demonstrated no stent thrombosis. The rate of major cardiac adverse events (a composite of cardiovascular death, myocardial infarction and target lesion revascularisation) at 1 year was 3.8%. No severe bleeding events, stroke or late stent thrombosis were noted. One-year follow-up was associated with good clinical outcomes and compared favorably with current devices.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Clopidogrel/administración & dosificación , Materiales Biocompatibles Revestidos , Enfermedad de la Arteria Coronaria/terapia , Trombosis Coronaria/prevención & control , Inhibidores de Agregación Plaquetaria/administración & dosificación , Stents , Anciano , Anciano de 80 o más Años , Angioplastia Coronaria con Balón/efectos adversos , Aleaciones de Cromo , Clopidogrel/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Trombosis Coronaria/etiología , Femenino , Hemorragia/inducido químicamente , Humanos , Masculino , Compuestos Organofosforados , Inhibidores de Agregación Plaquetaria/efectos adversos , Polímeros , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA