Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 256
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Nat Methods ; 21(4): 619-622, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38443506

RESUMEN

Orbitrap-based charge detection mass spectrometry utilizes single-molecule sensitivity to enable mass analysis of even highly heterogeneous, high-mass macromolecular assemblies. For contemporary Orbitrap instruments, the accessible ion detection (recording) times are maximally ~1-2 s. Here by modifying a data acquisition method on an Orbitrap ultrahigh mass range mass spectrometer, we trapped and monitored individual (single) ions for up to 25 s, resulting in a corresponding and huge improvement in signal-to-noise ratio (×5 compared with 1 s), mass resolution (×25) and accuracy in charge and mass determination of Orbitrap-based charge detection mass spectrometry.


Asunto(s)
Espectrometría de Masas , Espectrometría de Masas/métodos , Análisis Espectral , Iones
2.
Mol Cell Proteomics ; 23(2): 100713, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38184013

RESUMEN

Optimizing data-independent acquisition methods for proteomics applications often requires balancing spectral resolution and acquisition speed. Here, we describe a real-time full mass range implementation of the phase-constrained spectrum deconvolution method (ΦSDM) for Orbitrap mass spectrometry that increases mass resolving power without increasing scan time. Comparing its performance to the standard enhanced Fourier transformation signal processing revealed that the increased resolving power of ΦSDM is beneficial in areas of high peptide density and comes with a greater ability to resolve low-abundance signals. In a standard 2 h analysis of a 200 ng HeLa digest, this resulted in an increase of 16% in the number of quantified peptides. As the acquisition speed becomes even more important when using fast chromatographic gradients, we further applied ΦSDM methods to a range of shorter gradient lengths (21, 12, and 5 min). While ΦSDM improved identification rates and spectral quality in all tested gradients, it proved particularly advantageous for the 5 min gradient. Here, the number of identified protein groups and peptides increased by >15% in comparison to enhanced Fourier transformation processing. In conclusion, ΦSDM is an alternative signal processing algorithm for processing Orbitrap data that can improve spectral quality and benefit quantitative accuracy in typical proteomics experiments, especially when using short gradients.


Asunto(s)
Proteoma , Espectrometría de Masas en Tándem , Humanos , Proteoma/metabolismo , Espectrometría de Masas en Tándem/métodos , Péptidos/análisis , Células HeLa , Proteómica/métodos
3.
Mol Cell Proteomics ; 23(5): 100760, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38579929

RESUMEN

We describe deep analysis of the human proteome in less than 1 h. We achieve this expedited proteome characterization by leveraging state-of-the-art sample preparation, chromatographic separations, and data analysis tools, and by using the new Orbitrap Astral mass spectrometer equipped with a quadrupole mass filter, a high-field Orbitrap mass analyzer, and an asymmetric track lossless (Astral) mass analyzer. The system offers high tandem mass spectrometry acquisition speed of 200 Hz and detects hundreds of peptide sequences per second within data-independent acquisition or data-dependent acquisition modes of operation. The fast-switching capabilities of the new quadrupole complement the sensitivity and fast ion scanning of the Astral analyzer to enable narrow-bin data-independent analysis methods. Over a 30-min active chromatographic method consuming a total analysis time of 56 min, the Q-Orbitrap-Astral hybrid MS collects an average of 4319 MS1 scans and 438,062 tandem mass spectrometry scans per run, producing 235,916 peptide sequences (1% false discovery rate). On average, each 30-min analysis achieved detection of 10,411 protein groups (1% false discovery rate). We conclude, with these results and alongside other recent reports, that the 1-h human proteome is within reach.


Asunto(s)
Proteoma , Proteómica , Espectrometría de Masas en Tándem , Humanos , Proteoma/análisis , Proteómica/métodos , Factores de Tiempo
4.
Anal Chem ; 96(14): 5392-5398, 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38526848

RESUMEN

Along with mass spectrometry (MS), ion mobility separations (IMS) are advancing to ever larger biomolecules. The emergence of electrospray ionization (ESI) and native MS enabled the IMS/MS analyses of proteins up to ∼100 kDa in the 1990s and whole protein complexes and viruses up to ∼10 MDa since the 2000s. Differential IMS (FAIMS) is substantially orthogonal to linear IMS based on absolute mobility K and offers exceptional resolution, unique selectivity, and steady filtering readily compatible with slower analytical methods such as electron capture or transfer dissociation (ECD/ETD). However, the associated MS stages had limited FAIMS to ions with m/z < 8000 and masses under ∼300 kDa. Here, we integrate high-definition FAIMS with the Q-Exactive Orbitrap UHMR mass spectrometer that can handle m/z up to 80,000 and MDa-size ions in the native ESI regime. In the initial evaluation, the oligomers of monoclonal antibody adalimumab (148 kDa) are size-selected up to at least the nonamers (1.34 MDa) with m/z values up to ∼17,000. This demonstrates the survival and efficient separation of noncovalent MDa assemblies in the FAIMS process, opening the door to novel analyses of the heaviest macromolecules.


Asunto(s)
Espectrometría de Movilidad Iónica , Proteínas , Espectrometría de Masas/métodos , Proteínas/química , Iones
5.
Anal Chem ; 96(21): 8234-8242, 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38739527

RESUMEN

Mass spectrometry has been increasingly explored in intraoperative studies as a potential technology to help guide surgical decision making. Yet, intraoperative experiments using high-performance mass spectrometry instrumentation present a unique set of operational challenges. For example, standard operating rooms are often not equipped with the electrical requirements to power a commercial mass spectrometer and are not designed to accommodate their permanent installation. These obstacles can impact progress and patient enrollment in intraoperative clinical studies because implementation of MS instrumentation becomes limited to specific operating rooms that have the required electrical connections and space. To expand our intraoperative clinical studies using the MasSpec Pen technology, we explored the feasibility of transporting and acquiring data on Orbitrap mass spectrometers operating on battery power in hospital buildings. We evaluated the effect of instrument movement including acceleration and rotational speeds on signal stability and mass accuracy by acquiring data using direct infusion electrospray ionization. Data were acquired while rolling the systems in/out of operating rooms and while descending/ascending a freight elevator. Despite these movements and operating the instrument on battery power, the relative standard deviation of the total ion current was <5% and the magnitude of the mass error relative to the internal calibrant never exceeded 5.06 ppm. We further evaluated the feasibility of performing intraoperative MasSpec Pen analysis while operating the Orbitrap mass spectrometer on battery power during an ovarian cancer surgery. We observed that the rich and tissue-specific molecular profile commonly detected from ovarian tissues was conserved when running on battery power. Together, these results demonstrate that Orbitrap mass spectrometers can be operated and acquire data on battery power while in motion and in rotation without losses in signal stability or mass accuracy. Furthermore, Orbitrap mass spectrometers can be used in conjunction to the MasSpec Pen while on battery power for intraoperative tissue analysis.


Asunto(s)
Suministros de Energía Eléctrica , Humanos , Espectrometría de Masas/métodos , Femenino , Neoplasias Ováricas/cirugía
6.
Anal Chem ; 96(1): 127-136, 2024 01 09.
Artículo en Inglés | MEDLINE | ID: mdl-38126724

RESUMEN

In vitro/in vivo detection of copper ions is a challenging task but one which is important in the development of new approaches to the diagnosis and treatment of cancer and hereditary diseases such as Alzheimer's, Wilson's, etc. In this paper, we present a nanopipette sensor capable of measuring Cu2+ ions with a linear range from 0.1 to 10 µM in vitro and in vivo. Using the gold-modified nanopipette sensor with a copper chelating ligand, we evaluated the accumulation ability of the liposomal form of an anticancer Cu-containing complex at three levels of biological organization. First, we detected Cu2+ ions in a single cell model of human breast adenocarcinoma MCF-7 and in murine melanoma B16 cells. The insertion of the nanoelectrode did not result in leakage of the cell membrane. We then evaluated the distribution of the Cu-complex in MCF-7 tumor spheroids and found that the diffusion-limited accumulation was a function of the depth, typical for 3D culture. Finally, we demonstrated the use of the sensor for Cu2+ ion detection in the brain of an APP/PS1 transgenic mouse model of Alzheimer's disease and tumor-bearing mice in response to injection (2 mg kg-1) of the liposomal form of the anticancer Cu-containing complex. Enhanced stability and selectivity, as well as distinct copper oxidation peaks, confirmed that the developed sensor is a promising tool for testing various types of biological systems. In summary, this research has demonstrated a minimally invasive electrochemical technique with high temporal resolution that can be used for the study of metabolism of copper or copper-based drugs in vitro and in vivo.


Asunto(s)
Enfermedad de Alzheimer , Neoplasias , Ratones , Humanos , Animales , Cobre , Enfermedad de Alzheimer/diagnóstico , Iones , Técnicas Electroquímicas
7.
Rapid Commun Mass Spectrom ; 38(6): e9657, 2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38342682

RESUMEN

RATIONALE: Characterization of Regolith And Trace Economic Resources (CRATER), an Orbitrap™-based laser desorption mass spectrometry instrument designed to conduct high-precision, spatially resolved analyses of planetary materials, is capable of answering outstanding science questions about the Moon's formation and the subsequent processes that have modified its (sub)surface. METHODS: Here, we describe the baseline design of the CRATER flight model, which requires <20 000 cm3  volume, <10 kg mass, and <60 W peak power. The analytical capabilities and performance metrics of a prototype that meets the full functionality of the flight model are demonstrated. RESULTS: The instrument comprises a high-power, solid-state, pulsed ultraviolet (213 nm) laser source to ablate the surface of the lunar sample, a custom ion optical interface to accelerate and collimate the ions produced at the ablation site, and an Orbitrap mass analyzer capable of discriminating competing isobars via ultrahigh mass resolution and high mass accuracy. The CRATER instrument can measure elemental and isotopic abundances and characterize the organic content of lunar surface samples, as well as identify economically valuable resources for future exploration. CONCLUSION: An engineering test unit of the flight model is currently in development to serve as a pathfinder for near-term mission opportunities.

8.
J Chem Inf Model ; 64(3): 918-932, 2024 Feb 12.
Artículo en Inglés | MEDLINE | ID: mdl-38241093

RESUMEN

Beta amyloid peptide Aß 1-42 (Aß42) has a unique dual role in the human organism, as both the peptide with an important physiological function and one of the most toxic biological compounds provoking Alzheimer's disease (AD). There are several known Aß42 isoforms that we discuss here that are highly neurotoxic and lead to the early onset of AD. Aß42 is an intrinsically disordered protein with no experimentally solved structure under physiological conditions. The objective of this research was to establish the appropriate molecular dynamics (MD) methodology and model a uniform set of structures for the Aß42 isoforms that form the core of this study. For that purpose, force field selection and verification including convergence testing for MD simulations was made. Replica exchange MD and conventional MD modeling of several Aß42 and Aß16 isoforms that have neurotoxic and amyloidogenic effects impacting the severity of Alzheimer's disease were carried out with the optimal force field and solvent parameters. A standardized ensemble of structures for the Aß42 and Aß16 isoforms covering 30-50% of the conformational ensembles extracted from the free energy minima was calculated from MD trajectories. The resulting data set of modeled structures includes Aß42 wild type, isoD7, pS8, D7H, and H6R-Aß42 and Aß16 wild type, isoD7, pS8, D7H, and H6R-Aß16. The representative structures are given in the Supporting Information; they are open for public access. In the study, we also evaluated the differences between the structures of Aß42 isoforms and speculate on their possible relevance to the known functions. Utilizing several representative structures for a single disordered protein for docking, with their subsequent averaging by conformations, would markedly increase the reliability of docking results.


Asunto(s)
Enfermedad de Alzheimer , Péptidos beta-Amiloides , Humanos , Péptidos beta-Amiloides/química , Simulación de Dinámica Molecular , Enfermedad de Alzheimer/metabolismo , Reproducibilidad de los Resultados , Isoformas de Proteínas/metabolismo , Fragmentos de Péptidos/química , Amiloide
9.
Angew Chem Int Ed Engl ; : e202317064, 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38769756

RESUMEN

Nanoelectromechanical systems (NEMS)-based mass spectrometry (MS) is an emerging technique that enables determination of the mass of individual adsorbed particles by driving nanomechanical devices at resonance and monitoring the real-time changes in their resonance frequencies induced by each single molecule adsorption event. We incorporate NEMS into an Orbitrap mass spectrometer and report our progress towards leveraging the single-molecule capabilities of the NEMS to enhance the dynamic range of conventional MS instrumentation and to offer new capabilities for performing deep proteomic analysis of clinically relevant samples. We use the hybrid instrument to deliver E. coli GroEL molecules (801 kDa) to the NEMS devices in their native, intact state. Custom ion optics are used to focus the beam down to 40 µm diameter with a maximum flux of 25 molecules/second. The mass spectrum obtained with NEMS-MS shows good agreement with the known mass of GroEL.

10.
J Proteome Res ; 22(10): 3290-3300, 2023 10 06.
Artículo en Inglés | MEDLINE | ID: mdl-37683181

RESUMEN

We evaluate the quantitative performance of the newly released Asymmetric Track Lossless (Astral) analyzer. Using data-independent acquisition, the Thermo Scientific Orbitrap Astral mass spectrometer quantifies 5 times more peptides per unit time than state-of-the-art Thermo Scientific Orbitrap mass spectrometers, which have long been the gold standard for high-resolution quantitative proteomics. Our results demonstrate that the Orbitrap Astral mass spectrometer can produce high-quality quantitative measurements across a wide dynamic range. We also use a newly developed extracellular vesicle enrichment protocol to reach new depths of coverage in the plasma proteome, quantifying over 5000 plasma proteins in a 60 min gradient with the Orbitrap Astral mass spectrometer.


Asunto(s)
Péptidos , Proteómica , Proteómica/métodos , Espectrometría de Masas/métodos , Proteoma/metabolismo , Proteínas Sanguíneas
11.
Anal Chem ; 95(19): 7656-7664, 2023 05 16.
Artículo en Inglés | MEDLINE | ID: mdl-37133913

RESUMEN

The measurement of collision cross sections (CCS, σ) offers supplemental information about sizes and conformations of ions beyond mass analysis alone. We have previously shown that CCSs can be determined directly from the time-domain transient decay of ions in an Orbitrap mass analyzer as ions oscillate around the central electrode and collide with neutral gas, thus removing them from the ion packet. Herein, we develop the modified hard collision model, thus deviating from the prior FT-MS hard sphere model, to determine CCSs as a function of center-of-mass collision energy in the Orbitrap analyzer. With this model, we aim to increase the upper mass limit of CCS measurement for native-like proteins, characterized by low charge states and presumed to be in more compact conformations. We also combine CCS measurements with collision induced unfolding and tandem mass spectrometry experiments to monitor protein unfolding and disassembly of protein complexes and measure CCSs of ejected monomers from protein complexes.


Asunto(s)
Proteínas , Proteínas/química , Iones/química
12.
Anal Chem ; 95(32): 12039-12046, 2023 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-37534599

RESUMEN

We describe an instrument configuration based on the Orbitrap Exploris 480 mass spectrometer that has been coupled to an Omnitrap platform. The Omnitrap possesses three distinct ion-activation regions that can be used to perform resonant-based collision-induced dissociation, several forms of electron-associated fragmentation, and ultraviolet photodissociation. Each section can also be combined with infrared multiphoton dissociation. In this work, we demonstrate all these modes of operation in a range of peptides and proteins. The results show that this instrument configuration produces similar data to previous implementations of each activation technique and at similar efficiency levels. We demonstrate that this unique instrument configuration is extremely versatile for the investigation of polypeptides.


Asunto(s)
Electrones , Péptidos , Péptidos/química , Proteínas/análisis , Espectrometría de Masas/métodos , Proyectos de Investigación
13.
Anal Chem ; 95(43): 15943-15949, 2023 10 31.
Artículo en Inglés | MEDLINE | ID: mdl-37856787

RESUMEN

ß-Amyloid aggregation on living cell surfaces is described as responsible for the neurotoxicity associated with different neurodegenerative diseases. It is suggested that the aggregation of ß-amyloid (Aß) peptide on neuronal cell surface leads to various deviations of its vital function due to myriad pathways defined by internalization of calcium ions, apoptosis promotion, reduction of membrane potential, synaptic activity loss, etc. These are associated with structural reorganizations and pathologies of the cell cytoskeleton mainly involving actin filaments and microtubules and consequently alterations of cell mechanical properties. The effect of amyloid oligomers on cells' Young's modulus has been observed in a variety of studies. However, the precise connection between the formation of amyloid aggregates on cell membranes and their effects on the local mechanical properties of living cells is still unresolved. In this work, we have used correlative scanning ion-conductance microscopy (SICM) to study cell topography, Young's modulus mapping, and confocal imaging of Aß aggregate formation on living cell surfaces. However, it is well-known that the cytoskeleton state is highly connected to the intracellular level of reactive oxygen species (ROS). The effect of Aß leads to the induction of oxidative stress, actin polymerization, and stress fiber formation. We measured the reactive oxygen species levels inside single cells using platinum nanoelectrodes to demonstrate the connection of ROS and Young's modulus of cells. SICM can be successfully applied to studying the cytotoxicity mechanisms of Aß aggregates on living cell surfaces.


Asunto(s)
Péptidos beta-Amiloides , Microscopía , Especies Reactivas de Oxígeno/metabolismo , Péptidos beta-Amiloides/química , Citoesqueleto/metabolismo , Membrana Celular/metabolismo , Amiloide/química , Fragmentos de Péptidos/química
14.
Anal Chem ; 95(42): 15656-15664, 2023 Oct 24.
Artículo en Inglés | MEDLINE | ID: mdl-37815927

RESUMEN

The growing trend toward high-throughput proteomics demands rapid liquid chromatography-mass spectrometry (LC-MS) cycles that limit the available time to gather the large numbers of MS/MS fragmentation spectra required for identification. Orbitrap analyzers scale performance with acquisition time and necessarily sacrifice sensitivity and resolving power to deliver higher acquisition rates. We developed a new mass spectrometer that combines a mass-resolving quadrupole, the Orbitrap, and the novel Asymmetric Track Lossless (Astral) analyzer. The new hybrid instrument enables faster acquisition of high-resolution accurate mass (HRAM) MS/MS spectra compared with state-of-the-art mass spectrometers. Accordingly, new proteomics methods were developed that leverage the strengths of each HRAM analyzer, whereby the Orbitrap analyzer performs full scans with a high dynamic range and resolution, synchronized with the Astral analyzer's acquisition of fast and sensitive HRAM MS/MS scans. Substantial improvements are demonstrated over previous methods using current state-of-the-art mass spectrometers.

15.
Nat Methods ; 17(4): 395-398, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32152501

RESUMEN

We demonstrate single-particle charge detection mass spectrometry on an Orbitrap for the analysis of megadalton biomolecular assemblies. We establish that the signal amplitudes of individual ions scale linearly with their charge, which can be used to resolve mixed ion populations, determine charge states and thus also determine the masses of individual ions. This enables the ultrasensitive analysis of heterogeneous protein assemblies including immunoglobulin oligomers, ribosomes, proteinaceous nanocontainers and genome-packed adeno-associated viruses.


Asunto(s)
Sustancias Macromoleculares/química , Espectrometría de Masas/métodos , Sensibilidad y Especificidad
16.
Nat Methods ; 17(4): 391-394, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32123391

RESUMEN

An Orbitrap-based ion analysis procedure determines the direct charge for numerous individual protein ions to generate true mass spectra. This individual ion mass spectrometry (I2MS) method for charge detection enables the characterization of highly complicated mixtures of proteoforms and their complexes in both denatured and native modes of operation, revealing information not obtainable by typical measurements of ensembles of ions.


Asunto(s)
Espectrometría de Masas/métodos , Proteínas/química , Proteómica/métodos , Humanos
17.
Mass Spectrom Rev ; 41(1): 100-151, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-33169900

RESUMEN

Laser ionization mass spectrometry (LIMS) was one of the first practical methods developed for in situ analysis of the surfaces of solid samples. This review will encompass several aspects related to this analytical method. First, we will discuss the process of laser ionization, the influence of the laser type on its performance, and imaging capabilities of this method. In the second chapter, we will follow the historic development of LIMS instrumentation. After a brief overview of the first-generation instruments developed in 1960-1990 years, we will discuss in detail more recent designs, which appeared during the last 2-3 decades. In the last part of our review, we will cover the recent applications of LIMS for surface analysis. These applications include various types of analyses of solid inorganic, organic, and heterogeneous samples, often in combination with depth profiling and imaging capability.


Asunto(s)
Rayos Láser , Espectrometría de Masas/métodos , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos
18.
Mass Spectrom Rev ; : e21775, 2022 Mar 28.
Artículo en Inglés | MEDLINE | ID: mdl-35347731

RESUMEN

This review covers the results of the application of mass spectrometric (MS) techniques to study the diversity of beta-amyloid (Aß) peptides in human samples. Since Aß is an important hallmark of Alzheimer's disease (AD), which is a socially significant neurodegenerative disorder of the elderly worldwide, analysis of its endogenous variations is of particular importance for elucidating the pathogenesis of AD, predicting increased risks of the disease onset, and developing effective therapy. MS approaches have no alternative for the study of complex samples, including a wide variety of Aß proteoforms, differing in length and modifications. Approaches based on matrix-assisted laser desorption/ionization time-of-flight and liquid chromatography with electrospray ionization tandem MS are most common in Aß studies. However, Aß forms with isomerized and/or racemized Asp and Ser residues require the use of special methods for separation and extra sensitive and selective methods for detection. Overall, this review summarizes current knowledge of Aß species found in human brain, cerebrospinal fluid, and blood plasma; focuses on application of different MS approaches for Aß studies; and considers the potential of MS techniques for further studies of Aß-peptides.

19.
Biochemistry (Mosc) ; 88(Suppl 1): S88-S104, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37069116

RESUMEN

ß-amyloid (Aß) is comprised of a group of peptides formed as a result of cleavage of the amyloid precursor protein by secretases. Aß aggregation is considered as a central event in pathogenesis of Alzheimer's disease, the most common human neurodegenerative disorder. Molecular mechanisms of Aß aggregation have intensively being investigated using synthetic Aß peptides by methods based on monitoring of aggregates, including determination of their size and structure. In this review, an orthogonal approach to the study of Aß aggregation is considered, which relies on electrochemical registration of the loss of peptide monomers. Electrochemical analysis of Aß (by voltammetry and amperometric flow injection analysis) is based on registration of the oxidation signal of electroactive amino acid residues of the peptide on an electrode surface. The Aß oxidation signal disappears, when the peptide is included in the aggregate. The advantages and disadvantages of electrochemical analysis for the study of spontaneous and metal-induced aggregation of Aß, comparative analysis of various peptide isoforms, and study of the process of complexation of metal ions with the metal-binding domain of Aß are discussed. It is concluded that the combined use of the electrochemical method and the methods based on detection of Aß aggregates makes it possible to obtain more complete information about the mechanisms of peptide aggregation.


Asunto(s)
Enfermedad de Alzheimer , Péptidos beta-Amiloides , Humanos , Péptidos beta-Amiloides/metabolismo , Enfermedad de Alzheimer/metabolismo , Precursor de Proteína beta-Amiloide/metabolismo , Oxidación-Reducción , Aminoácidos , Fragmentos de Péptidos/química
20.
Proc Natl Acad Sci U S A ; 117(37): 22841-22848, 2020 09 15.
Artículo en Inglés | MEDLINE | ID: mdl-32859757

RESUMEN

Quantum mechanics/molecular mechanics (QM/MM) maturation of an immunoglobulin (Ig) powered by supercomputation delivers novel functionality to this catalytic template and facilitates artificial evolution of biocatalysts. We here employ density functional theory-based (DFT-b) tight binding and funnel metadynamics to advance our earlier QM/MM maturation of A17 Ig-paraoxonase (WTIgP) as a reactibody for organophosphorus toxins. It enables regulation of biocatalytic activity for tyrosine nucleophilic attack on phosphorus. The single amino acid substitution l-Leu47Lys results in 340-fold enhanced reactivity for paraoxon. The computed ground-state complex shows substrate-induced ionization of the nucleophilic l-Tyr37, now H-bonded to l-Lys47, resulting from repositioning of l-Lys47. Multiple antibody structural homologs, selected by phenylphosphonate covalent capture, show contrasting enantioselectivities for a P-chiral phenylphosphonate toxin. That is defined by crystallographic analysis of phenylphosphonylated reaction products for antibodies A5 and WTIgP. DFT-b analysis using QM regions based on these structures identifies transition states for the favored and disfavored reactions with surprising results. This stereoselection analysis is extended by funnel metadynamics to a range of WTIgP variants whose predicted stereoselectivity is endorsed by experimental analysis. The algorithms used here offer prospects for tailored design of highly evolved, genetically encoded organophosphorus scavengers and for broader functionalities of members of the Ig superfamily, including cell surface-exposed receptors.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA