Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
J Surg Res ; 280: 129-150, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35969932

RESUMEN

Capsular contracture is a common complication associated with breast implants following reconstructive or aesthetic surgery in which a tight or constricting scar tissue capsule forms around the implant, often distorting the breast shape and resulting in chronic pain. Capsulectomy (involving full removal of the capsule surrounding the implant) and capsulotomy (where the capsule is released and/or partly removed to create more space for the implant) are the most common surgical procedures used to treat capsular contracture. Various structural modifications of the implant device (including use of textured implants, submuscular placement of the implant, and the use of polyurethane-coated implants) and surgical strategies (including pre-operative skin washing and irrigation of the implant pocket with antibiotics) have been and/or are currently used to help reduce the incidence of capsular contracture. In this article, we review the pharmacological approaches-both commonly practiced in the clinic and experimental-reported in the scientific and clinical literature aimed at either preventing or treating capsular contracture, including (i) pre- and post-operative intravenous administration of drug substances, (ii) systemic (usually oral) administration of drugs before and after surgery, (iii) modification of the implant surface with grafted drug substances, (iv) irrigation of the implant or peri-implant tissue with drugs prior to implantation, and (v) incorporation of drugs into the implant shell or filler prior to surgery followed by drug release in situ after implantation.


Asunto(s)
Implantación de Mama , Implantes de Mama , Contractura , Humanos , Contractura Capsular en Implantes/etiología , Contractura Capsular en Implantes/prevención & control , Contractura Capsular en Implantes/epidemiología , Poliuretanos , Implantes de Mama/efectos adversos , Implantación de Mama/efectos adversos , Implantación de Mama/métodos , Contractura/prevención & control , Contractura/complicaciones , Antibacterianos
2.
AIDS Behav ; 26(9): 2954-2968, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35294694

RESUMEN

Steroid-releasing vaginal rings are available for contraception and estrogen replacement therapy, and a new antiretroviral-releasing ring was recently approved for HIV prevention. Marketed rings are white or transparent in appearance, non-scented, and supplied as one-size-fits-all devices with diameters ranging from 54 to 56 mm. In this study, drug-free silicone elastomer rings were manufactured in different sizes, colors and scents, and the opinions/preferences of 16 women (eThekwini District, South Africa; 20-34 years) assessed through focus group discussions and thematic analysis. Opinions varied on ring color and scent, with some women preferring specific colors or scent intensities, while for others these attributes were unimportant. Concerns about color and scent were linked to perceptions around vaginal health and safety related to chemical composition. There was greater agreement on preferred ring size; flexibility and width were considered important factors for insertion and comfort. Greater choice with ring products could facilitate acceptability and overall uptake.


Asunto(s)
Dispositivos Anticonceptivos Femeninos , Infecciones por VIH , Anticoncepción , Femenino , Grupos Focales , Infecciones por VIH/tratamiento farmacológico , Infecciones por VIH/prevención & control , Humanos , Sudáfrica/epidemiología
3.
Artículo en Inglés | MEDLINE | ID: mdl-28784672

RESUMEN

5P12-RANTES, a chemokine analogue that potently blocks the HIV CCR5 coreceptor, is being developed as both a vaginal and rectal microbicide for prevention of sexual transmission of HIV. Here, we report the first pharmacokinetic data for 5P12-RANTES following single-dose vaginal gel administration in sheep. Aqueous gel formulations containing low (1.24-mg/ml), intermediate (6.18-mg/ml), and high (32.0-mg/ml; suspension-type gel) concentrations of 5P12-RANTES were assessed via rheology, syringeability, and in vitro release testing. Following vaginal gel administration to sheep, 5P12-RANTES concentrations were measured in vaginal fluid, vaginal tissue, and serum over a 96-h period. All gels showed non-Newtonian pseudoplastic behavior, with the high-concentration gels exhibiting a greater viscosity and cohesive structure than the intermediate- and low-concentration gels. In in vitro release testing, >90% 5P12-RANTES was released from the low- and intermediate-concentration gels after 72 h. For the high-concentration gel, ∼50% 5P12-RANTES was detected, attributed to protein denaturation during lyophilization and/or subsequent solvation of the protein within the gel matrix. In sheep, 5P12-RANTES concentrations in vaginal fluid, vaginal tissue, and serum increased in a dose-dependent manner. The highest concentrations were measured in vaginal fluid (105 to 107 ng/ml), followed by vaginal tissue (104 to 106 ng/ml). Both of these concentration ranges are several orders of magnitude above the reported half-maximal inhibitory concentrations. The lowest concentration was measured in serum (<102 ng/ml). The 5P12-RANTES pharmacokinetic data are similar to those reported previously for other candidate microbicides. These data, coupled with 5P12-RANTES's potency at picomolar concentrations, its strong barrier to resistance, and the full protection that it was observed to provide in a rhesus macaque vaginal challenge model, support the continued development of 5P12-RANTES as a microbicide.


Asunto(s)
Fármacos Anti-VIH/farmacocinética , Antagonistas de los Receptores CCR5/farmacocinética , Quimiocinas CC/farmacocinética , Cremas, Espumas y Geles Vaginales/farmacocinética , Administración Intravaginal , Animales , Femenino , Infecciones por VIH/tratamiento farmacológico , VIH-1/efectos de los fármacos , Ovinos
4.
J Antimicrob Chemother ; 69(5): 1325-9, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24381072

RESUMEN

OBJECTIVES: This study measured and compared the pharmacokinetics of CMPD167, a small molecule antiretroviral CCR5 inhibitor with potential as an HIV microbicide, following vaginal, rectal and oral administration in rhesus macaques. METHODS: A vaginal hydroxyethylcellulose (HEC) gel, a rectal HEC gel, a silicone elastomer matrix-type vaginal ring and an oral solution, each containing CMPD167, were prepared and administered to rhesus macaques pretreated with Depo-Provera. CMPD167 concentrations in vaginal fluid, vaginal tissue (ring only), rectal fluid and blood plasma were quantified by HPLC-mass spectrometry. RESULTS: CMPD167 concentrations measured in rectal fluid, vaginal fluid and blood plasma were highly dependent on both the route of administration and the formulation type. Although rectal and vaginal fluid concentrations were highest when CMPD167 was administered locally (via either gel or ring), lower concentrations of the drug were also measured in these compartments following administration at the remote mucosal site or orally. CMPD167 levels in the vaginal and rectal fluid following oral administration were relatively low compared with local administration. CONCLUSIONS: The study provides clear evidence for vaginal-rectal and rectal-vaginal drug transfer pathways and suggests that oral pre-exposure prophylaxis with CMPD167 may be less efficacious at preventing sexual transmission of HIV-1 than topically applied products.


Asunto(s)
Fármacos Anti-VIH/administración & dosificación , Fármacos Anti-VIH/farmacocinética , Antagonistas de los Receptores CCR5/administración & dosificación , Antagonistas de los Receptores CCR5/farmacocinética , Pirazoles/administración & dosificación , Pirazoles/farmacocinética , Receptores del VIH/antagonistas & inhibidores , Valina/análogos & derivados , Administración Intravaginal , Administración Oral , Administración Rectal , Animales , Líquidos Corporales/química , Cromatografía Líquida de Alta Presión , Femenino , Macaca mulatta , Masculino , Espectrometría de Masas , Valina/administración & dosificación , Valina/farmacocinética
5.
J Antimicrob Chemother ; 69(9): 2477-88, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24862093

RESUMEN

OBJECTIVES: Combination microbicide vaginal rings may be more effective than single microbicide rings at reducing/preventing sexual transmission of HIV. Here, we report the pre-clinical development and macaque pharmacokinetics of matrix-type silicone elastomer vaginal rings containing dapivirine and darunavir. METHODS: Macaque rings containing 25 mg dapivirine, 100 mg dapivirine, 300 mg darunavir or 100 mg dapivirine+300 mg darunavir were manufactured and characterized by differential scanning calorimetry. In vitro release was assessed into isopropanol/water and simulated vaginal fluid. Macaque vaginal fluid and blood serum concentrations for both antiretrovirals were measured during 28 day ring use. Tissue levels were measured on day 28. Ex vivo challenge studies were performed on vaginal fluid samples and IC50 values were calculated. RESULTS: Darunavir caused a concentration-dependent reduction in the dapivirine melting temperature in both solid drug mixes and in the combination ring. In vitro release from rings was dependent on drug loading, the number of drugs present and the release medium. In macaques, serum concentrations of both microbicides were maintained between 10(1) and 10(2) pg/mL. Vaginal fluid levels ranged between 10(3) and 10(4) ng/g and between 10(4) and 10(5) ng/g for dapivirine and darunavir, respectively. Both dapivirine and darunavir showed very similar concentrations in each tissue type; the range of drug tissue concentrations followed the general rank order: vagina (1.8 × 10(3)-3.8 × 10(3) ng/g)  > cervix (9.4 × 10(1)-3.9 × 10(2) ng/g)  > uterus (0-108 ng/g)  > rectum (0-40 ng/g). Measured IC50 values were >2 ng/mL for both compounds. CONCLUSIONS: Based on these results, and in light of recent clinical progress of the 25 mg dapivirine ring, a combination vaginal ring containing dapivirine and darunavir is a viable second-generation HIV microbicide candidate.


Asunto(s)
Fármacos Anti-VIH/uso terapéutico , Dispositivos Anticonceptivos Femeninos , Transmisión de Enfermedad Infecciosa/prevención & control , Infecciones por VIH/prevención & control , Profilaxis Pre-Exposición/métodos , Pirimidinas/uso terapéutico , Sulfonamidas/uso terapéutico , Animales , Fármacos Anti-VIH/farmacocinética , Líquidos Corporales/química , Cuello del Útero/química , Darunavir , Modelos Animales de Enfermedad , Quimioterapia Combinada/métodos , Femenino , Humanos , Concentración 50 Inhibidora , Macaca , Pirimidinas/farmacocinética , Recto/química , Sulfonamidas/farmacocinética , Útero/química , Vagina/química
6.
J Antimicrob Chemother ; 68(3): 678-83, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-23111849

RESUMEN

OBJECTIVES: To investigate the pharmacokinetics (PK) of maraviroc, a CCR5-targeted HIV-1 entry inhibitor, in rhesus macaques following vaginal administration of various maraviroc-loaded aqueous hydroxyethylcellulose (HEC) gels, and to correlate the PK data with efficacy in a single high-dose vaginal SHIV-162P3 challenge model. METHODS: Maraviroc concentrations in vaginal fluid (Weck-Cel(®) sponge), vaginal tissue (punch biopsy) and plasma were assessed over 72 h following single-dose vaginal application of various maraviroc-loaded HEC gels. The range of maraviroc gel concentrations was sufficiently broad (0.003%-3.3% w/w) that test gels included both fully solubilized and predominantly dispersed formulations. The efficacy of the HEC gels against a single high-dose vaginal SHIV-162P3 challenge was also measured, and correlated with the PK concentrations. RESULTS: Maraviroc concentrations in vaginal fluid (range 10(4)-10(7) ng/mL), vaginal tissue (100-1200 ng/g) and plasma (<10(2) ng/mL) were highly dependent on maraviroc gel loading, irrespective of the form of the maraviroc component within the gel (solubilized versus dispersed). Fluid and plasma concentrations were generally highest 0.5 or 2 h after gel application, before declining steadily through to 72 h. Maraviroc concentrations in the various biological compartments correlated strongly with the extent of protection against vaginal SHIV-162P3 challenge. Complete protection was achieved with a 3.3% w/w maraviroc gel. CONCLUSIONS: A high degree of correlation between PK and efficacy was observed. Based on the data obtained with the 3.3% w/w maraviroc gel, maintenance of vaginal fluid and tissue levels in the order of 10(7) ng/mL and 10(3) ng/g, respectively, are required for complete protection with this compound.


Asunto(s)
Ciclohexanos/administración & dosificación , Ciclohexanos/farmacocinética , Inhibidores de Fusión de VIH/administración & dosificación , Inhibidores de Fusión de VIH/farmacocinética , Síndrome de Inmunodeficiencia Adquirida del Simio/prevención & control , Triazoles/administración & dosificación , Triazoles/farmacocinética , Cremas, Espumas y Geles Vaginales/administración & dosificación , Administración Intravaginal , Animales , Líquidos Corporales/química , Femenino , Macaca mulatta , Maraviroc , Plasma/química , Factores de Tiempo , Vagina/química
7.
J Antimicrob Chemother ; 68(2): 394-403, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23109186

RESUMEN

OBJECTIVES: The non-nucleoside reverse transcriptase inhibitor MC1220 has potent in vitro activity against HIV type 1 (HIV-1). A liposome gel formulation of MC1220 has previously been reported to partially protect rhesus macaques against vaginal challenge with a simian HIV (SHIV). Here, we describe the pre-clinical development of an MC1220-releasing silicone elastomer vaginal ring (SEVR), including pharmacokinetic (PK) and efficacy studies in macaques. METHODS: In vitro release studies were conducted on SEVRs loaded with 400 mg of MC1220, using simulated vaginal fluid (SVF, n = 4) and 1 : 1 isopropanol/water (IPA/H(2)O, n = 4) as release media. For PK evaluation, SEVRs were inserted into adult female macaques (n = 6) for 30 days. Following a 1 week washout period, fresh rings were placed in the same animals, which were then challenged vaginally with RT-SHIV162P3 once weekly for 4 weeks. RESULTS: SEVRs released 1.66 and 101 mg of MC1220 into SVF and IPA/H(2)O, respectively, over 30 days, the differential reflecting the low aqueous solubility of the drug. In macaque PK studies, MC1220 was consistently detected in vaginal fluid (peak 845 ng/mL) and plasma (peak 0.91 ng/mL). Kaplan-Meier analysis over 9 weeks showed significantly lower infection rates for animals given MC1220-containing SEVRs than placebo rings (hazard ratio 0.20, P = 0.0037). CONCLUSIONS: An MC1220-releasing SEVR partially protected macaques from vaginal challenge. Such ring devices are a practical method for providing sustained, coitally independent protection against vaginal exposure to HIV-1.


Asunto(s)
Antivirales/administración & dosificación , Dispositivos Anticonceptivos Femeninos , Portadores de Fármacos , Pirimidinonas/administración & dosificación , Elastómeros de Silicona/administración & dosificación , Síndrome de Inmunodeficiencia Adquirida del Simio/prevención & control , Virus de la Inmunodeficiencia de los Simios/patogenicidad , Animales , Antivirales/farmacocinética , Líquidos Corporales/química , Femenino , Fluorobencenos , Humanos , Macaca mulatta , Plasma/química , Pirimidinonas/farmacocinética , Resultado del Tratamiento , Vagina/química
8.
Drug Deliv ; 30(1): 2180113, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36815245

RESUMEN

Polymeric drug-releasing vaginal rings are useful for both local and systemic administration of drugs via the intravaginal route. Typically, they provide continuous sustained or controlled release of drug(s) over extended time periods, thereby avoiding overdose and improving adherence. This first-in-human study (EudraCT number: 2020-0050044-30) evaluated the pharmacokinetics, safety, and tolerability of a single dose of oxybutynin administered by a novel microprocessor-controlled vaginal ring (MedRing). Eight healthy female subjects received an electronically controlled single intravaginal dose of 3 mg oxybutynin hydrochloride (100 mg/mL) dissolved in 1:1 water/propylene glycol administered via MedRing. Following dosing, MedRing was kept in situ for up to 6 h. Blood samples were collected 1 h prior to oxybutynin dosing and subsequently at regular intervals post-dose for the assessment of plasma concentrations of oxybutynin and its active metabolite N-desethyloxybutynin. The results showed that MedRing efficiently administered oxybutynin via the intravaginal route, resulting in plasma oxybutynin levels comparable to orally administered oxybutynin. The mean ± standard deviation pharmacokinetic parameters for oxybutynin were Cmax 5.4 ± 2.7 ng/mL, AUCinf 34.9 ± 17.4 h ng/mL, t1/2 8.5 ± 3.5 h and for N-desethyloxybutynin were Cmax 3.9 ± 2.5 ng/mL, AUCinf 51.1 ± 43.1 h ng/mL, t1/2 7.7 ± 5.9 h. No serious adverse events were reported. The study demonstrates that intravaginal administration of oxybutynin hydrochloride using the MedRing device was well tolerated.


Asunto(s)
Antagonistas Colinérgicos , Ácidos Mandélicos , Humanos , Femenino , Antagonistas Colinérgicos/efectos adversos , Estudios Cruzados , Ácidos Mandélicos/metabolismo , Ácidos Mandélicos/uso terapéutico
9.
Int J Pharm ; 648: 123572, 2023 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-37926178

RESUMEN

Bacterial vaginosis (BV) is a common but often asymptomatic dysbiosis of the human vagina characterized by an imbalance in the normal vaginal microbiota due to loss of lactobacilli and an overgrowth of certain anaerobic bacteria. While BV itself is not a sexually transmitted infection, it is associated with an increased risk in women of various sexually acquired infections, including human immunodeficiency virus (HIV) infection. There is, therefore, a strong rationale for pursuing new multipurpose products that seek to treat or prevent BV alongside preventing HIV infection. With the dapivirine-releasing vaginal ring for HIV prevention now approved in several African countries, here we report formulation development of a next-generation ring product that releases both dapivirine (DPV) and the antibiotic drug metronidazole (MET). Following thermal analysis studies to characterize the phase behaviour of DPV-MET mixtures and rheological analysis to assess the cure characteristics of the active silicone elastomer mixes, matrix-type rings were manufactured containing 25 or 200 mg DPV in combination with 100, 250, 500, 1000 or 2000 mg MET. The results for drug content, in vitro release, mechanical testing, and Gardnerella vaginalis time-kill experiments demonstrate the feasibility of incorporating both DPV and MET in a matrix-type ring formulation and indicate that clinically effective release rates may be possible.


Asunto(s)
Dispositivos Anticonceptivos Femeninos , Infecciones por VIH , Vaginosis Bacteriana , Femenino , Humanos , Vaginosis Bacteriana/tratamiento farmacológico , Vaginosis Bacteriana/prevención & control , Metronidazol , Infecciones por VIH/tratamiento farmacológico , Infecciones por VIH/prevención & control , Vagina/microbiología
10.
Drug Deliv Transl Res ; 13(8): 2072-2082, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-34674162

RESUMEN

Previously reported in vitro release test methods for drug-releasing vaginal rings containing poorly water-soluble drugs have described use of water-alcohol systems or surfactant solutions in efforts to maintain sink conditions. Here, as part of efforts to more closely match in vitro and in vivo release for the 25 mg dapivirine matrix-type silicone elastomer vaginal ring for HIV prevention, we have investigated alternatives to the 1:1 v/v water/isopropanol medium described previously. Specifically, we evaluated dapivirine release from rings into (i) monophasic water/isopropanol mixtures of varying compositions and (ii) biphasic buffer/octanol systems using pH 4.2 and pH 7.0 buffers. The rate and mechanism of dapivirine release were dependent upon the isopropanol concentration in the release medium, in accordance with the observed trend in drug solubility. At 0 and 10% v/v isopropanol concentrations, dapivirine release followed a partition-controlled mechansim. For media containing ≥ 20% v/v isopropanol, in vitro release of dapivirine was significantly increased and obeyed permeation-controlled kinetics. Cumulative release of ~3.5 mg dapivirine over 28 days was obtained using a water isopropanol mixture containing 20% v/v isopropanol, similar to the ~4 mg dapivirine released in vivo. Dapivirine release into the biphasic buffer/octanol system (intended to mimic the fluid/tissue environment in vivo) was constrained by the limited solubility of dapivirine in the buffer component in which the ring resided, such that cumulative dapivirine release was consistently lower than that observed with the 20% v/v isopropanol in water medium. Release into the biphasic system was also pH dependent, in line with dapivirine's pKa and with potential implications for in vivo release and absorption in women with elevated vaginal pH.


Asunto(s)
Fármacos Anti-VIH , Dispositivos Anticonceptivos Femeninos , Infecciones por VIH , Humanos , Femenino , Fármacos Anti-VIH/química , 2-Propanol/análisis , Vagina , Infecciones por VIH/prevención & control
11.
Antimicrob Agents Chemother ; 56(5): 2251-8, 2012 May.
Artículo en Inglés | MEDLINE | ID: mdl-22330914

RESUMEN

Antiretroviral entry inhibitors are now being considered as vaginally administered microbicide candidates for the prevention of the sexual transmission of human immunodeficiency virus. Previous studies testing the entry inhibitors maraviroc and CMPD167 in aqueous gel formulations showed efficacy in the macaque challenge model, although protection was highly dependent on the time period between initial gel application and subsequent challenge. In this paper, we describe the sustained release of maraviroc and CMPD167 from matrix-type silicone elastomer vaginal rings both in vitro and in vivo. Both inhibitors were released continuously during 28 days from rings in vitro at rates of 100 to 2,500 µg/day. In 28-day pharmacokinetic studies in rhesus macaques, the compounds were measured in the vaginal fluid and vaginal tissue; steady-state fluid concentrations were ~10(6)-fold greater than the 50% inhibitory concentrations (IC(50)s) for simian human immunodeficiency virus 162P3 inhibition in macaque lymphocytes in vitro. Plasma concentrations for both compounds were very low. The pretreatment of macaques with Depo-Provera (DP), which is commonly used in macaque challenge studies, was shown to significantly modify the biodistribution of the inhibitors but not the overall amount released. Vaginal fluid and tissue concentrations were significantly decreased while plasma levels increased with DP pretreatment. These observations have implications for designing macaque challenge experiments and also for ring performance during the human female menstrual cycle.


Asunto(s)
Antagonistas de los Receptores CCR5 , Ciclohexanos/farmacocinética , Pirazoles/farmacocinética , Síndrome de Inmunodeficiencia Adquirida del Simio/prevención & control , Virus de la Inmunodeficiencia de los Simios/efectos de los fármacos , Triazoles/farmacocinética , Valina/análogos & derivados , Internalización del Virus/efectos de los fármacos , Administración Intravaginal , Animales , Fármacos Anti-VIH/administración & dosificación , Fármacos Anti-VIH/farmacocinética , Biopsia , Cromatografía Líquida de Alta Presión , Dispositivos Anticonceptivos Femeninos , Ciclohexanos/administración & dosificación , Preparaciones de Acción Retardada/administración & dosificación , Femenino , Infecciones por VIH/prevención & control , VIH-1/efectos de los fármacos , VIH-1/fisiología , Humanos , Estudios Longitudinales , Macaca mulatta , Maraviroc , Acetato de Medroxiprogesterona/administración & dosificación , Pirazoles/administración & dosificación , Síndrome de Inmunodeficiencia Adquirida del Simio/sangre , Síndrome de Inmunodeficiencia Adquirida del Simio/virología , Virus de la Inmunodeficiencia de los Simios/fisiología , Distribución Tisular , Triazoles/administración & dosificación , Vagina/efectos de los fármacos , Vagina/virología , Valina/administración & dosificación , Valina/farmacocinética
12.
Int J Pharm X ; 4: 100112, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35128382

RESUMEN

We have previously reported a multipurpose silicone elastomer vaginal ring providing sustained release of dapivirine (an antiretroviral) and levonorgestrel (a progestin) for HIV prevention and hormonal contraception. During initial development, issues arose due to reaction between the ethynyl group in the levonorgestrel molecule and the hydride-functionalised polydimethylsiloxane components in the silicone elastomer formulation. This unwanted reaction occurred both during and to a lesser extent after ring manufacture, impacting the curing process, the mechanical properties of the ring, and the in vitro release of levonorgestrel. Recently, we reported custom silicone elastomer grades that minimise this reaction. In this follow-on study, we describe the manufacture, in vitro drug release, mechanical, and pharmaceutical stability testing of ring formulations prepared from a custom silicone elastomer and containing 200 mg dapivirine and 80, 160, 240 or 320 mg levonorgestrel. The rings showed mechanical properties similar to marketed ring products, sustained in vitro release of both drugs over 30 days in quantities deemed clinically relevant, offered acceptable assay values, and provided good product stability over 15 weeks at 40 °C and 75% relative humidity.

13.
Int J Pharm ; 607: 121040, 2021 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-34450222

RESUMEN

Electrospinning is an innovative technique that allows production of nanofibers and microfibers by applying a high voltage to polymer solutions of melts. The properties of these fibers - which include high surface area, high drug loading capacity, and ability to be manufactured from mucoadhesive polymers - may be particularly useful in a myriad of drug delivery and tissue engineering applications. The last decade has witnessed a surge of interest in the application of electrospinning technology for the fabrication of vaginal drug delivery systems for the treatment and prevention of diseases associated with women's sexual and reproductive health, including sexually transmitted infections (e.g. infection with human immunodeficiency virus and herpes simplex virus) vaginitis, preterm birth, contraception, multipurpose prevention technology strategies, cervicovaginal cancer, and general maintenance of vaginal health. Due to their excellent mechanical properties, electrospun scaffolds are also being investigated as next-generation materials in the surgical treatment of pelvic organ prolapse. In this article, we review the latest advances in the field.


Asunto(s)
Nanofibras , Nacimiento Prematuro , Sistemas de Liberación de Medicamentos , Femenino , Humanos , Embarazo , Salud Reproductiva , Ingeniería de Tejidos
14.
Int J Pharm X ; 3: 100091, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34977558

RESUMEN

A dapivirine-releasing silicone elastomer vaginal ring for reducing women's risk of HIV acquisition has recently been approved. A next-generation multipurpose vaginal ring releasing dapivirine and levonorgestrel is currently in development, offering hormonal contraception and HIV prevention from a single device. Previously, we reported challenges with incorporating levonorgestrel into rings manufactured from addition-cure silicone elastomers due to an irreversible chemical reaction between the levonorgestrel molecule and the hydride-functionalised crosslinker component of the silicone elastomer formulation, leading to low drug content assay, cure inhibition, and reduced ring mechanical properties (which may account for the increased incidence of ring expulsion in vivo). Here, we report on the development and testing of various custom silicone elastomer materials specifically formulated to circumvent these issues. After extensive testing of the custom silicones and subsequent manufacture and testing (Shore M hardness, pot life, content assay, oscillatory rheology, mechanical testing) of rings containing both dapivirine and levonorgestrel, a lead candidate formulation was selected that was amenable to practical ring manufacture via injection molding, exhibited no substantial levonorgestrel binding, and offered suitable mechanical properties.

15.
Int J Pharm X ; 3: 100081, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34027386

RESUMEN

Vaginal rings releasing antiretrovirals - either alone or in combination with contraceptive progestins - are being developed for prevention of human immunodeficiency virus (HIV) transmission via vaginal sex. Following Phase I trials, significant discolouration was observed on the surface of investigational silicone elastomer antiretroviral-contraceptive matrix-type vaginal rings containing either 25 mg dapivirine or 200 mg dapivirine plus levonorgestrel. In this study, potential causes of the discolouration have been assessed in vitro using simulated vaginal and menstrual fluids (SVF and SMF, respectively) to model in vivo exposure. The fluid compositions also included hydrogen peroxide (H2O2), hydrogen peroxide plus a copper intrauterine device (IUD), or synthetic dyes (representing personal care and household cleaning products). No discolouration was observed for rings exposed to SVF + hydrogen peroxide (with or without an IUD). However, the SVF + dye compositions showed significant ring discolouration, with staining patterns similar to those observed with rings that had been exposed to highly-coloured personal care and household cleaning products during clinical trial use. Exposure of rings to SMF compositions invariably caused yellow surface discolouration, dark spotting and markings, similar to the staining patterns observed following clinical use. The darker marks on the ring surface were identified as blood debris derived from the SMF. The study indicates that surface discolouration of rings in vivo can be attributed to exposure to menstrual fluid or highly coloured personal care or household cleaning products. Discolouration of the rings was not associated with any specific safety risks for the user, though severe discolouration could potentially impact acceptability and adherence.

16.
Expert Opin Drug Deliv ; 17(11): 1519-1540, 2020 11.
Artículo en Inglés | MEDLINE | ID: mdl-32684013

RESUMEN

INTRODUCTION: There is considerable interest in vaginal ring technology for sustained/controlled administration of drugs to the human vagina. Seven drug-releasing vaginal rings have reached market and other experimental devices are in preclinical/clinical development. Although most women who have used rings are satisfied and find them acceptable, involuntary expulsions and voluntary removals are known to occur and are widely reported. There have been no previous efforts to review this topic and understand the factors contributing  to expulsions. AREAS COVERED: This article will help researchers, clinicians and product developers better understand the pertinent factors and issues around ring expulsions and removals, and inform new research aimed at optimizing ring product design. The review contains four sections: (i) introduction to vaginal ring technology; (ii) discussion of the anatomical, physiological, device, and user factors affecting ring expulsion; (iii) review of involuntary expulsions; (iv) review of voluntary removals; and (v) concluding remarks/opinions. EXPERT OPINION: Further research is needed to better understand the factors contributing to involuntary ring expulsions and removals so that rings can be better designed to minimize rates of expulsion and to reduce removals. Determination of optimum ring dimensions and stiffness are likely key factors, alongside better counseling around removal and reinsertion.


Asunto(s)
Dispositivos Anticonceptivos Femeninos , Preparaciones Farmacéuticas/administración & dosificación , Femenino , Humanos
17.
Biomacromolecules ; 10(9): 2427-35, 2009 Sep 14.
Artículo en Inglés | MEDLINE | ID: mdl-19642670

RESUMEN

This investigation describes the formulation and characterization of rheologically structured vehicles (RSVs) designed for improved drug delivery to the vagina. Interactive, multicomponent, polymeric platforms were manufactured containing hydroxyethylcellulose (HEC, 5% w/w) polyvinylpyrrolidone (PVP, 4% w/w), Pluronic (PL, 0 or 10% w/w), and either polycarbophil (PC, 3% w/w) or poly(methylvinylether-co-maleic anhydride) (Gantrez S97, 3% w/w) as a mucoadhesive agent. The rheological (torsional and dynamic), mechanical (compressional), and mucoadhesive properties were characterized and shown to be dependent upon the mucoadhesive agent used and the inclusion/exclusion of PL. The dynamic rheological properties of the gel platforms were also assessed following dilution with simulated vaginal fluid (to mimic in vivo dilution). RSVs containing PC were more rheologically structured than comparator formulations containing GAN. This trend was also reflected in formulation hardness, compressibility, consistency, and syringeability. Moreover, formulations containing PL (10% w/w) were more rheologically structured than formulations devoid of PL. Dilution with simulated vaginal fluids significantly decreased rheological structure, although RSVs still retained a highly elastic structure (G' > G'' and tan delta < 1). Furthermore, RSVs exhibited sustained drug release properties that were shown to be dependent upon their rheological structure. It is considered that these semisolid drug delivery systems may be useful as site-retentive platforms for the sustained delivery of therapeutic agents to the vagina.


Asunto(s)
Sistemas de Liberación de Medicamentos/métodos , Geles/química , Adhesividad , Administración Intravaginal , Preparaciones de Acción Retardada , Fenómenos Mecánicos , Reología
18.
J Med Primatol ; 38(4): 263-71, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19476564

RESUMEN

BACKGROUND: There is considerable interest in developing coitally independent, sustained release formulations for long-term administration of HIV microbicides. Vaginal ring devices are at the forefront of this formulation strategy. METHODS: Non-medicated silicone elastomer vaginal rings were prepared having a range of appropriate dimensions for testing vaginal fit in pig-tailed and Chinese rhesus macaques. Cervicovaginal proinflammatory markers were evaluated. Compression testing was performed to compare the relative flexibility of various macaque and commercial human rings. RESULTS: All rings remained in place during the study period and no tissue irritation or significant induction of cervicovaginal proinflammatory markers or signs of physical discomfort were observed during the 8-week study period. CONCLUSIONS: Qualitative evaluation suggests that the 25 x 5-mm ring provided optimal fit in both macaque species. Based on the results presented here, low-consistency silicone elastomers do not cause irritation in macaques and are proposed as suitable materials for the manufacture of microbicide-loaded vaginal rings.


Asunto(s)
Fármacos Anti-VIH/administración & dosificación , Equipos y Suministros , Administración Intravaginal , Animales , Equipos y Suministros/efectos adversos , Equipos y Suministros/veterinaria , Femenino , VIH , Macaca mulatta , Macaca nemestrina , Mecánica
19.
Int J Pharm ; 572: 118725, 2019 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-31648014

RESUMEN

Here we report the first use of an additive manufacturing (AM) technique based on high pressure material jetting of molten thermoplastic for the fabrication of dapivirine (DPV) loaded vaginal rings (VRs). The VRs are compared to those produced conventionally using injection molding (IM). VRs (outer diameter 54.0 mm, cross-sectional diameter 4.0 mm) were manufactured by either injection molding or Arburg Plastic Freeforming (APF) - a proprietary droplet deposition modelling (DDM) process, using medical grade thermoplastic polyurethanes (TPUs) loaded with 10% w/w DPV. This unique DDM process was used to produce rings of 100, 50 and 10% matrix infill density. DDM printed VRs with 10% density (57-62 mg drug load) exhibited up to seven-fold increase in DPV release compared to injection molded rings containing 190-194 mg DPV. This work has shown that DDM using the APF technique can be used to manufacture drug delivery devices of varying geometries, densities and surface areas to give precise levels of control over the drug release kinetics. This work presents a new opportunity to increase the release of poorly water-soluble compounds or to achieve desired dosing levels using lower drug loadings than those required using conventional thermoplastic processing techniques.


Asunto(s)
Fármacos Anti-VIH/química , Dispositivos Anticonceptivos Femeninos , Sistemas de Liberación de Medicamentos/instrumentación , Diseño de Equipo , Poliuretanos/química , Pirimidinas/química , Liberación de Fármacos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA