Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Eur Heart J ; 38(16): 1194-1203, 2017 Apr 21.
Artículo en Inglés | MEDLINE | ID: mdl-28039339

RESUMEN

AIMS: Calcified aortic stenosis (AS) and mitral annular calcification (MAC) have certain similar etiology and pathophysiological mechanisms. MAC is frequently encountered in pre-procedural computed tomography (CT) imaging of patients that undergo transcatheter aortic valve replacement (TAVR), but its prognostic implications for these patients have not been thoroughly investigated. This study sought to evaluate the prevalence of MAC among patients with severe AS and to assess the clinical implications of MAC on these patients during and following TAVR. METHODS AND RESULTS: Consecutive patients that underwent TAVR were compared according to the existence of MAC and its severity in pre-TAVR CT scans. From the entire cohort of 761 patients, 49.3% had MAC, and 50.7% did not have MAC. Mild MAC was present in 231 patients (30.4%), moderate MAC in 72 patients (9.5%), and severe MAC in 72 patients (9.5%). Thirty-day mortality and major complications were similar between patients with and without MAC. In a multivariable survival analysis, severe MAC was found to be an independent strong predictor of overall mortality following TAVR (all-cause mortality: hazards ratio [HR] 1.95, 95% confidence interval [CI] 1.24-3.07, P = 0.004; cardiovascular mortality: HR 2.35, 95% CI 1.19-4.66; P = 0.01). Severe MAC was also found to be an independent strong predictor of new permanent pacemaker implantation (PPI) after TAVR (OR 2.83, 95% CI 1.08-7.47; P = 0.03). CONCLUSION: Half of the patients with severe AS evaluated for TAVR were found to have MAC. Severe MAC is associated with increased all-cause and cardiovascular mortality and with conduction abnormalities following TAVR and should be included in future risk stratification models for TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica/complicaciones , Insuficiencia de la Válvula Mitral/complicaciones , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano de 80 o más Años , Válvula Aórtica/patología , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Calcinosis/complicaciones , Calcinosis/mortalidad , Calcinosis/cirugía , Femenino , Humanos , Masculino , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/cirugía , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento , Calcificación Vascular/complicaciones , Calcificación Vascular/mortalidad , Calcificación Vascular/cirugía
2.
Catheter Cardiovasc Interv ; 89(3): 462-468, 2017 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-27219874

RESUMEN

BACKGROUND: Significant paravalvular leak (PVL) occurs in up to 13% of patients after transcatheter aortic valve replacement (TAVR) with a balloon-expandable bioprosthesis. Transcatheter PVL repair has emerged as a less invasive alternative for this problem. OBJECTIVES: The aim of this study was to evaluate the safety, feasibility, and clinical outcomes of transcatheter PVL repair after TAVR with balloon-expandable valve. METHODS: We retrospectively identified 15 patients who underwent 16 PVL repair procedures after the TAVR at our center. Procedural characteristics, results, and clinical outcomes were analyzed. The association of PVL repairs with subsequent hospitalizations and mortality was assessed and compared to 57 patients who did not undergo repair for at least moderate PVL after TAVR. RESULTS: The PVL repair was successful in 13 (87%) patients, without significant procedure or device related complications. In patients with successful PVL repair, there was an improvement in symptom status, subsequent hospitalizations, and B-type natriuretic peptide levels. There was 1 (out of 13, 8%) death in the group of patients who successfully underwent PVL repair whereas 24 (out of 57, 42%) patients died during follow up in the group that did not undergo repair of their PVL. Similarly, there was significant reduction in the subsequent heart failure related hospitalization after the PVL repair, compared with the patients who did not undergo PVL repair (P = 0.03). CONCLUSION: Transcatheter repair of PVL after TAVR can be safely and effectively accomplished in carefully selected patients, and may lead to reduction in hospitalizations, improvement in symptoms, and long-term survival. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Insuficiencia de la Válvula Aórtica/terapia , Válvula Aórtica , Valvuloplastia con Balón , Cateterismo Cardíaco/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/mortalidad , Insuficiencia de la Válvula Aórtica/fisiopatología , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/mortalidad , Supervivencia sin Enfermedad , Ecocardiografía Transesofágica , Estudios de Factibilidad , Femenino , Insuficiencia Cardíaca/etiología , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Estimación de Kaplan-Meier , Los Angeles , Masculino , Readmisión del Paciente , Selección de Paciente , Diseño de Prótesis , Retratamiento , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
3.
Circ J ; 81(7): 1036-1042, 2017 Jun 23.
Artículo en Inglés | MEDLINE | ID: mdl-28331113

RESUMEN

BACKGROUND: The aim of this study was to determine the influence of an elliptic annulus on acute device success rates following self-expanding (SE) transcatheter aortic valve replacement (TAVR) vs. balloon-expandable (BE) TAVR.Methods and Results:Outcomes were assessed using Valve Academic Research Consortium-2 definitions. Aortic annulus ratio (AAR) was measured as short axis diameter/long axis diameter. Mean AAR was 0.81±0.06. Patients were therefore divided into 2 groups: AAR <0.82 and AAR ≥0.82. For circular annuli (AAR ≥0.82; 363 patients), high device success rates were achieved in both valve groups (SE valve, 90.5% vs. BE valve, 95.0%, P=0.14). Conversely, for AAR <0.82 (374 patients), SE valves had lower device success rates than BE valves (82.5% vs. 95.3%, P=0.002). For elliptic annuli, SE-TAVR was an independent predictor of unsuccessful device implantation (OR, 6.34, P<0.001). Nonetheless, increased oversizing of SE valves for elliptic annuli was associated with an exponential rise in device success (threshold ≥17.5%; area under the curve, 0.83) but not for BE-TAVR. Furthermore, optimally oversized SE valves and BE valves had a similarly high device success for elliptic annuli (SE valve, 96.2% vs. BE valve, 95.3%). CONCLUSIONS: For circular annuli, similarly high device success was achieved for the 2 valve types. Conversely, for elliptic annuli, SE valves had a lower device success than BE valves. Device success following optimal oversizing of SE valves, however, was similar to that for BE valves.


Asunto(s)
Válvula Aórtica , Anuloplastia de la Válvula Cardíaca/métodos , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Femenino , Humanos , Masculino
4.
Int Heart J ; 58(1): 56-62, 2017 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-28100877

RESUMEN

Severe device landing zone calcification (DLZ-CA) predicted paravalvular leak (PVL) and post-dilatation (PD) after transcatheter aortic valve implantation (TAVI). The aim of this study was to determine the influence of DLZ-CA on PVL or PD rates after SAPIEN XT (XT) versus CoreValve (CV).We analyzed patients undergoing TAVI who had severe DLZ-CA. Severe DLZ-CA defined the upper left ventricular outflow tract calcification; the cross-sectional region 2 mm inferior to the annular plane. PVL was evaluated at 30days using transthoracic echocardiography. Overall, 133 patients had XT-TAVI and the remaining 41 patients had CV-TAVI. Two patients had annulus injury in the XT group (oversizing 20.2% and 20.5% for two XT cases). PD was less frequently performed in the XT group (34.1% versus 12.8%; P = 0.002), but PVL rates were similar between both groups (42.1% versus 41.5% for the XT and CV groups, respectively; P = 0.94). Importantly, excessive oversizing or the degree of filling volume was not associated with decreased PVL after XT-TAVI (P = non-significant for all). On multivariate analysis, CV-TAVI was found to be one of the independent predictors of need for PD (Odds ratio 3.63, 95% confidence interval 1.55 to 8.53, P = 0.003).In the setting of severe DLZ-CA, XT and CV have similar rates of PVL but XT had less need for PD. Excessive oversizing with XT carries a risk of root injury which could be further increased by DLZ-CA.


Asunto(s)
Válvula Aórtica , Calcinosis/etiología , Prótesis Valvulares Cardíacas/efectos adversos , Complicaciones Posoperatorias/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Dilatación , Femenino , Prótesis Valvulares Cardíacas/estadística & datos numéricos , Humanos , Masculino , Estudios Prospectivos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación
5.
Catheter Cardiovasc Interv ; 88(1): 127-34, 2016 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26756702

RESUMEN

OBJECTIVES: To investigate the influence of body mass index (BMI) on short- and midterm outcomes following transcatheter aortic valve implantation (TAVI). BACKGROUND: Although obesity is a major risk factor for cardiovascular mortality, numerous studies reported a beneficial effect of obesity on survival in patients with cardiovascular disease and in patients after cardiac interventions. Moreover, all previous reports examining the relation between BMI and outcomes following TAVI have underscored the "obesity paradox" in these patients. METHODS: During a 3 year period, 805 patients with severe aortic stenosis that underwent TAVI at our institute were evaluated. Based on baseline BMI, patients were classified as normal weight (18.5-24.9 kg/m(2) ), overweight (25.0-29.9 kg/m(2) ), or obese (≥30 kg/m(2) ). TAVI endpoints, device success, and adverse events were considered according to the Valve Academic Research Consortium (VARC)-2 definitions. RESULTS: Obese patients were significantly younger, had higher prevalence of diabetes mellitus and chronic lung disease, and had lower prevalence of frailty. Device success was similar between the 3 groups. All-cause mortality up to 30 days was 2.9% (10/340) vs 4.5% (12/268) vs 0.5% (1/186) in patients with normal weight, overweight, and obesity, respectively (p = 0.048). In a multivariable model, overweight and obese patients had similar overall mortality compared to patients with normal weight. CONCLUSIONS: We found no evidence for the existence of an obesity paradox following TAVI. Correction for possible confounders such as frailty in the present cohort may explain the discrepancy between the current report and the previous reports that suggested a protective effect for increased BMI following TAVI. © 2016 Wiley Periodicals, Inc.


Asunto(s)
Estenosis de la Válvula Aórtica/terapia , Válvula Aórtica , Índice de Masa Corporal , Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Obesidad/complicaciones , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/mortalidad , Distribución de Chi-Cuadrado , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Humanos , Los Angeles , Masculino , Análisis Multivariante , Obesidad/diagnóstico , Obesidad/mortalidad , Modelos de Riesgos Proporcionales , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento
6.
Eur Heart J Cardiovasc Imaging ; 19(12): 1408-1418, 2018 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-29315371

RESUMEN

Aims: We assessed the geometry of transcatheter heart valve (THV) and valve function associated with SAPIEN 3 implantation in patients with bicuspid aortic valve (BAV) stenosis. Methods and results: We included 280 consecutive patients who had a contrast computed tomography (CT) before and after transcatheter aortic valve implantation (TAVI) in our institution. Each THV was assessed by CT at five cross-sectional levels: inflow, annulus, mid, sinus, and outflow. The geometry of THV was assessed for eccentricity (1 - minimum diameter/maximum diameter) and expansion (CT derived external valve area/nominal external valve area). CT measurements and transthoracic echocardiogram data were compared between BAV and tricuspid aortic valve (TAV). Among 280 patients, 41 patients were diagnosed as BAV. Compared to TAV, BAV was associated with lower expansion at mid-level, sinus-level, and outflow-level (mid 94.1 ± 6.8% vs. 98.1 ± 7.8%; P = 0.002, sinus 95.9 ± 7.2% vs. 101.6 ± 8.5%; P < 0.001, outflow 107.6 ± 6.2% vs. 109.9 ± 6.6%; P = 0.043), and higher eccentricity at all levels [inflow 3.5% (1.9-5.3) vs. 6.0% (3.2-7.5); P < 0.001, annulus 3.1% (1.6-5.2) vs. 5.4% (3.1-7.8); P = 0.002, mid 3.0% (1.4-4.9) vs. 6.0% (3.3-10.4); P < 0.001, sinus 3.0% (1.7-5.1) vs. 7.6% (4.0-11.4); P < 0.001, and outflow 2.5% (1.3-4.3) vs. 4.9% (2.2-7.5); P < 0.001]. There were no differences in frequency of paravalvular leak ≥ moderate and mean post-procedural gradient between BAV and TAV. Conclusion: BAV patients have greater THV eccentricity at all levels and lower THV expansion at mid, sinus, and outflow levels than the TAV patients. There were no differences in parameters of valve function between BAV and TAV patients. Despite the observed geometrical differences, TAVI with SAPIEN 3 in BAV patients allows for feasible valve function.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Enfermedades de las Válvulas Cardíacas/cirugía , Complicaciones Posoperatorias/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Análisis de Varianza , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Enfermedad de la Válvula Aórtica Bicúspide , Estudios de Cohortes , Femenino , Estudios de Seguimiento , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Prótesis Valvulares Cardíacas , Humanos , Ataque Isquémico Transitorio/diagnóstico por imagen , Ataque Isquémico Transitorio/etiología , Ataque Isquémico Transitorio/terapia , Masculino , Complicaciones Posoperatorias/fisiopatología , Complicaciones Posoperatorias/terapia , Estudios Retrospectivos , Medición de Riesgo , Estadísticas no Paramétricas , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/terapia , Tasa de Supervivencia , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía
7.
EuroIntervention ; 13(12): e1428-e1435, 2017 12 08.
Artículo en Inglés | MEDLINE | ID: mdl-28870874

RESUMEN

AIMS: Only a few studies have examined the respective impact of low flow (LF), low gradient (LG) and low ejection fraction (LEF) on outcomes following transcatheter aortic valve replacement (TAVR). The purpose of this study was to assess the impact of preprocedural stroke volume index, aortic valve gradient, left ventricular ejection fraction (LVEF) and different flow/gradient/LVEF patterns on the clinical outcomes of patients with severe aortic stenosis (AS) who undergo TAVR. METHODS AND RESULTS: We analysed the clinical, echocardiographic, and outcome data collected in 770 patients with AS who underwent TAVR. Overall, 357 patients had normal flow (NF) AS and 413 had LF AS. Patients with NF had similar one-year mortality (12.0% vs. 15.0%, p=0.23) compared with those in the LF group. Overall, patients with NF and/or HG had lower one-year mortality rates (11.7 to 13%) compared to those with paradoxical LF-LG with NEF (19%) and those with classical LF-LG with LEF (27.3%). Low mean gradient was an independent predictor of all-cause mortality (hazard ratio: 1.14, per 10 mmHg decrease, p=0.02). Despite significant association in univariable analyses, LF and LEF were not found to be predictors of outcomes in multivariable analyses. CONCLUSIONS: Patients with HG and those with NF-LG have low one-year mortality rates following TAVR, whereas those with classical LF-LG and LEF and those with paradoxical LF-LG and NEF have high and intermediate risk of mortality, respectively. In contradiction to previous reports, LG but not LF or LEF is an independent predictor of late mortality in high-risk patients with severe AS undergoing TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Humanos , Masculino , Quebec/epidemiología , Estudios Retrospectivos , Volumen Sistólico
8.
Eur Heart J Cardiovasc Imaging ; 18(6): 639-647, 2017 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-28369223

RESUMEN

AIMS: High aortic valve calcification (AVC) assessed with CT may be used to differentiate between severe and non-severe aortic stenosis (AS). Nonetheless, in some cases patients with low calcification are diagnosed with haemodynamically severe AS. The prevalence, mechanism of valve stenosis and implications for transcatheter aortic valve implantation (TAVI) of low AVC severe AS remain unclear. We assessed the clinical and haemodynamic characteristics and the outcome of patients with severe AS and low AVC that undergo TAVI. METHODS AND RESULTS: Ninety-three patients that had low CT aortic valve calcification score (AVCS) were compared to 470 patients with high AVCS. High gradient severe AS was found among 53.8% (50/93) of the patients with low AVCS vs. 86% (404/470) of the patients with high AVCS (P < 0.001). Device success rate was similar between both groups. There were significantly lower rates of postprocedural paravalvular regurgitation (PVR) in the low AVCS group (≥ mild PVR: 12.9% vs. 23.6%; P = 0.03). Overall, there were only two cases (0.4%) of valve embolization in patients with high AVCS and 1 (1.1%) in patients with low AVCS (P = 0.42). Thirty-day mortality and major complications were similar between groups. CONCLUSION: Balloon-expandable TAVI in patients with a mildly calcified aortic valve was not associated with increased risk of valve embolization or mortality. We demonstrated high device success and lower rates of PVR for these patients. These findings suggest that in patients with evidence of haemodynamically severe AS at echocardiography, the presence of low ACVS at CT should not preclude the consideration of TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/patología , Calcinosis/cirugía , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Factores de Edad , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Calcinosis/diagnóstico por imagen , Calcinosis/mortalidad , Estudios de Cohortes , Ecocardiografía Doppler/métodos , Femenino , Estudios de Seguimiento , Humanos , Estimación de Kaplan-Meier , Masculino , Análisis Multivariante , Modelos de Riesgos Proporcionales , Análisis de Regresión , Estudios Retrospectivos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Factores Sexuales , Tasa de Supervivencia , Tomografía Computarizada por Rayos X/métodos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
9.
JACC Cardiovasc Imaging ; 10(10 Pt A): 1139-1147, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28412434

RESUMEN

OBJECTIVES: This study sought to develop a robust and definitive risk model for new permanent pacemaker implantation (PPMI) after SAPIEN 3 (third generation balloon expandable valve) (Edwards Lifesciences, Irvine, California) transcatheter aortic valve replacement (third generation balloon expandable valve TAVR), including calcification in the aortic-valvular complex (AVC). BACKGROUND: The association between calcium in the AVC and need for PPMI is poorly delineated after third generation balloon expandable valve TAVR. METHODS: At Cedars-Sinai Heart Institute in Los Angeles, California, a total of 240 patients with severe aortic stenosis underwent third generation balloon expandable valve TAVR and had contrast computed tomography. AVC was characterized precisely by leaflet sector and region. RESULTS: The total new PPMI rate was 14.6%. On multivariate analysis for predictors of PPMI, pre-procedure third generation balloon expandable valve TAVR, right bundle branch block (RBBB), shorter membranous septum (MS) length, and noncoronary cusp device-landing zone calcium volume (NCC-DLZ CA) were included. Predictive probabilities were generated using this logistic regression model. If 3 pre-procedural risk factors were present, the c-statistic of the model for PPMI was area under the curve of 0.88, sensitivity of 77.1%, and specificity of 87.1%; this risk model had high negative predictive value (95.7%). The addition of the procedural factor of device depth to the model, with the parameter of difference between implantation depth and MS length, combined with RBBB and NCC-DLZ CA increased the c-statistic to 0.92, sensitivity to 94.3%, specificity to 83.8%, and negative predictive value to 98.8% CONCLUSIONS: By using a precise characterization of distribution of calcification in the AVC in a single-center, retrospective study, NCC-DLZ CA was found to be an independent predictor of new PPMI post-third generation balloon expandable valve TAVR. The findings also reinforce the importance of short MS length, pre-existing RBBB, and ventricular implantation depth as important synergistic PPMI risk factors. This risk model will need validation by future prospective multicenter studies.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/patología , Válvula Aórtica/cirugía , Bloqueo de Rama/terapia , Calcinosis/cirugía , Estimulación Cardíaca Artificial , Técnicas de Apoyo para la Decisión , Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Valvuloplastia con Balón/efectos adversos , Bloqueo de Rama/diagnóstico , Bloqueo de Rama/etiología , Bloqueo de Rama/fisiopatología , Calcinosis/diagnóstico por imagen , Calcinosis/fisiopatología , Bases de Datos Factuales , Femenino , Humanos , Modelos Logísticos , Los Angeles , Masculino , Tomografía Computarizada Multidetector , Análisis Multivariante , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Factores de Tiempo , Resultado del Tratamiento
10.
Am J Cardiol ; 120(11): 2017-2024, 2017 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-28941599

RESUMEN

Left ventricular outflow tract (LVOT) calcium is known to be associated with adverse procedural outcomes after transcatheter aortic valve implantation (TAVI), yet its effect on midterm outcomes has not been previously investigated. The aim of this study was to determine the influence of LVOT calcium on 2-year mortality after TAVI. A total of 537 consecutive patients underwent TAVI and 2 groups were established, stratified based on the severity of the LVOT calcium. The primary outcome was 2-year overall survival rate. The ≥moderate LVOT calcium group included 107 patients (19.9%) and the remaining 430 patients (80.1%) were included in the ≤mild LVOT calcium group. After a median follow-up of 717 days (interquartile range 484 to 828), the Kaplan-Meier analysis revealed that the 2-year overall survival probability was significantly lower in the ≥moderate LVOT calcium group than in the ≤mild LVOT calcium group (log-rank p = 0.001). On a Cox hazard model, ≥moderate LVOT calcium was associated with increased all-cause mortality after TAVI (hazard ratio 1.74, p = 0.009). In the subgroup analysis, based on valve designs, SAPIEN 3-TAVI done in the setting of ≥moderate LVOT calcium had a relatively similar survival probability as those of ≤mild LVOT calcium (log-rank p = 0.18), which is in contrast with older generation valves (log-rank p = 0.001). In conclusion, patients with ≥moderate LVOT calcium were shown to have a lower survival probability in the midterm follow-up after TAVI, compared with those with ≤mild LVOT calcium. Patients with high-grade LVOT calcium should be monitored with longer-term follow-ups after TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Calcinosis/complicaciones , Calcio/metabolismo , Ventrículos Cardíacos/diagnóstico por imagen , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Obstrucción del Flujo Ventricular Externo/etiología , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/mortalidad , Calcinosis/diagnóstico , Calcinosis/mortalidad , Ecocardiografía Tridimensional , Femenino , Estudios de Seguimiento , Prótesis Valvulares Cardíacas/efectos adversos , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Tomografía Computarizada Multidetector , Complicaciones Posoperatorias , Estudios Retrospectivos , Tasa de Supervivencia/tendencias , Estados Unidos/epidemiología , Obstrucción del Flujo Ventricular Externo/diagnóstico , Obstrucción del Flujo Ventricular Externo/mortalidad
11.
EuroIntervention ; 12(18): e2177-e2185, 2017 Apr 07.
Artículo en Inglés | MEDLINE | ID: mdl-28117281

RESUMEN

AIMS: The impact of left ventricular outflow tract calcification (LVOT-CA) on SAPIEN 3 transcatheter aortic valve replacement (S3-TAVR) is not well understood. The aims of the present study were to determine optimal device sizing for S3-TAVR in patients with or without LVOT-CA and to evaluate the influence of residual paravalvular leak (PVL) on survival after S3-TAVR in these patients. METHODS AND RESULTS: This study analysed 280 patients (LVOT-CA=144, no LVOT-CA=136) undergoing S3-TAVR. Optimal annular area sizing was defined as % annular area sizing related to lower rates of ≥mild PVL. Annular area sizing was determined as follows: (prosthesis area/CT annulus area-1)×100. Overall, ≥mild PVL was present in 25.7%. Receiver operating characteristic curve analysis for prediction of ≥mild PVL in patients with LVOT-CA showed that 7.2% annular area sizing was identified as the optimal threshold (area under the curve [AUC] 0.71). Conversely, annular area sizing for no LVOT-CA appeared unrelated to PVL (AUC 0.58). Aortic annular injury was seen in four patients (average 15.5% annular area oversizing), three of whom had LVOT-CA. Although there was no difference in one-year survival between patients with ≥mild PVL and without PVL (log-rank p=0.91), subgroup analysis demonstrated that patients with ≥moderate LVOT-CA who had ≥mild PVL had lower survival compared to patients with ≥mild PVL and none or mild LVOT-CA (log-rank p=0.010). CONCLUSIONS: In the setting of LVOT-CA, an optimally sized S3 valve is required to reduce PVL and to increase survival following TAVR.


Asunto(s)
Válvula Aórtica/anatomía & histología , Calcinosis/complicaciones , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Femenino , Humanos , Masculino , Tomografía Computarizada Multidetector , Complicaciones Posoperatorias/etiología , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Obstrucción del Flujo Ventricular Externo
12.
Int J Cardiol ; 244: 100-105, 2017 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-28622944

RESUMEN

AIMS: Self-expanding (SE) valves are characterized with long stent frame design and the radial force of the device exists both in the inflow and outflow level. Therefore, we hypothesized that device success of SE-valves may be influenced by ascending aortic dimensions (AAD). The aim of this study was to determine the influence of AAD on acute device success rates following SE transcatheter aortic valve replacement (TAVR). METHODS & RESULTS: In 4 centers in the United States and Asia, 214 consecutive patients underwent SE-TAVR. Outcomes were assessed in line with Valve Academic Research Consortium criteria. AAD was defined as the sum of the short and long axis aortic diameter divided by 2. Overall, device success rate was 85.0%. Multivariate analysis revealed that increased AAD (Odds ratio 1.27) and % oversizing (Odds ratio 0.88) were found to be independent predictors of unsuccessful device implantation. The c-statistic of the model for device success was area under the curve 0.79, sensitivity 81.3% and specificity 44.0%. Co-existence of several risk factors was associated with an exponential fall to 64.2% in device success rate. For a large AAD, however, optimally oversized SE-valves (threshold 16.2%) resulted with high device success rates compared to suboptimal oversizing (88.6% vs. 64.2%, p=0.005). CONCLUSIONS: Larger AAD and smaller degrees of oversizing were confirmed to be the most relevant predictors of unsuccessful device implantation following SE-valve implantations. Optimal oversizing of great significance was noted, particularly that with a large AAD.


Asunto(s)
Aorta/diagnóstico por imagen , Aorta/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Diseño de Prótesis/tendencias , Reemplazo de la Válvula Aórtica Transcatéter/tendencias , Anciano , Anciano de 80 o más Años , Estudios de Cohortes , Femenino , Humanos , Masculino , Estudios Retrospectivos , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Resultado del Tratamiento
13.
JACC Cardiovasc Imaging ; 9(8): 964-72, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-27424244

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the impact of increased aortic angulation (AA) on acute procedural success following transcatheter aortic valve replacement (TAVR). BACKGROUND: The degree of angulation between the aorta and the heart can make accurate positioning of the bioprosthesis during TAVR more demanding, particularly in instances of an extremely angulated or horizontal aortic root. Nonetheless, there are limited data on the impact of AA on the acute success of TAVR. METHODS: We assessed 582 patients who underwent TAVR at our institute and had contrast computed tomography available for AA evaluation. TAVR endpoints, device success, and adverse events were considered according to the Valve Academic Research Consortium-2 definitions. RESULTS: The mean angulation of the aorta was 47.3 ± 8.7°. Patients were therefore divided into 2 groups: AA <48° and AA ≥48°. AA in the 480 patients who underwent balloon-expandable (BE) TAVR did not influence acute procedural success or short-term clinical outcome. In contrast, increased AA among the 102 patients who underwent self-expandable (SE) TAVR was found to significantly attenuate procedural success (area under the curve: 0.73; 95% confidence interval: 0.61 to 0.85; p = 0.008). The numerical cutoff for AA with the highest sum of sensitivity and specificity for device success was ≥48° (sensitivity 85%, specificity 61%). Moreover, patients whose AA was ≥48° were also associated with an increased need for a second valve and post-dilation, had increased fluoroscopy time and increased valve embolization, and had increased post-procedural paravalvular regurgitation greater than or equal to mild following SE TAVR. Major complications at 30 days, including mortality were similar between AA groups. Six-month mortality was also similar between both AA groups. CONCLUSIONS: Increased aortic root angulation adversely influences acute procedural success following SE but not BE TAVR. Because of these data, BE valves may be preferred when evaluating patients with high AA before TAVR.


Asunto(s)
Aorta/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Aortografía/métodos , Valvuloplastia con Balón , Bioprótesis , Angiografía por Tomografía Computarizada , Prótesis Valvulares Cardíacas , Tomografía Computarizada Multidetector , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/etiología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/mortalidad , Valvuloplastia con Balón/efectos adversos , Valvuloplastia con Balón/mortalidad , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
14.
Am J Cardiol ; 117(10): 1636-1642, 2016 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-27015888

RESUMEN

Several clinical variables have been identified as predictors of clinical outcome after transcatheter aortic valve implantation (TAVI). Nonetheless, there is limited and contradictive data on the impact of diabetes mellitus (DM) on the prognosis of patients who undergo TAVI. We aimed to investigate the clinical characteristics and the early and midterm outcomes after TAVI according to DM status. From 802 consecutive patients who underwent TAVI, we compared 548 patients with no DM to 254 patients with diabetes (177 orally treated and 77 insulin treated). Patients with DM were younger had higher body mass index and incidence of coronary artery disease and lower incidence of frailty. Device success, 30-day mortality and major complications rates were similar between groups. One-year mortality was 12.1% for patient with DM and 12.2% for patients without DM (p = 0.91). In a multivariable regression analysis including age, body mass index, coronary artery disease and frailty, DM was associated with decreased overall survival. This was driven by increased overall mortality of the insulin-treated DM subgroup (hazard ratio 2.40, 95% CI 1.32 to 4.37; p <0.01). In conclusion, DM does not affect short-term mortality or rates of complications after TAVI. Insulin-treated DM, but not orally treated DM, is independently associated with death at midterm follow-up and therefore aggressive cardiovascular risk factor modification as well as intense glycemic control should be considered for patients with insulin-treated DM with severe aortic stenosis who undergo TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Diabetes Mellitus Tipo 2/complicaciones , Complicaciones Posoperatorias/epidemiología , Medición de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/mortalidad , California/epidemiología , Diabetes Mellitus Tipo 2/epidemiología , Femenino , Humanos , Incidencia , Masculino , Pronóstico , Estudios Retrospectivos , Tasa de Supervivencia/tendencias , Factores de Tiempo , Resultado del Tratamiento
15.
J Invasive Cardiol ; 28(10): 421-426, 2016 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-27705892

RESUMEN

OBJECTIVES: Aortic valve preparation with balloon aortic valvuloplasty (BAV) has been previously considered mandatory during transcatheter aortic valve implantation (TAVI) procedures. BAV-inherent risks including stroke, conduction abnormalities, and reduced device profile size established the rationale for safe valve deployment without the need for aggressive valve preparation. We investigate the feasibility and safety of performing Sapien 3 (S3; Edwards Lifesciences) balloon-expandable TAVI with moderate or without predilation (PD). METHODS: We examined consecutive patients with severe aortic stenosis who underwent S3-TAVI at our institution. Overall, 119 patients underwent TAVI without PD and 126 with moderate PD (mean valvuloplasty balloon diameter, 15.3 ± 2.1 mm). TAVI endpoints and adverse events were considered according to the Valve Academic Research Consortium (VARC)-2 definitions. RESULTS: Device success for the entire cohort was 98.8%. PD rates were similar between groups. Total fluoroscopy time and amount of contrast used were lower in the no PD group (13 min vs 16.2 min [P<.001] and 71.3 mL vs 81 mL [P=.03], respectively). All-cause mortality up to 30 days was 0% (0/119) in the no PD group vs 1.6% (2/126) in the moderate PD group (P=.49). VARC-2 defined complication rates at 30 days including cerebrovascular accident were similar between groups. Overall, there was no significant difference in survival rate between both groups (hazard ratio, 3.6; 95% confidence interval, 0.80-16.2; P=.09). CONCLUSIONS: Balloon-expandable TAVI using the S3 device with moderate or without balloon PD is feasible and safe. Omission of PD in appropriate cases was associated with reduced fluoroscopy time and total contrast used without affecting procedural success.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Complicaciones Posoperatorias , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Valvuloplastia con Balón/métodos , Cateterismo Cardíaco/métodos , Estudios de Factibilidad , Femenino , Fluoroscopía/métodos , Humanos , Masculino , Evaluación de Procesos y Resultados en Atención de Salud , Complicaciones Posoperatorias/diagnóstico , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/mortalidad , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Estados Unidos/epidemiología
16.
Am J Cardiol ; 116(12): 1904-9, 2015 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-26602075

RESUMEN

There are limited data on the effect of baseline B-type natriuretic peptide (BNP) on the outcome after transcatheter aortic valve implantation (TAVI). We investigated the influence of baseline BNP levels on the short-term and midterm clinical outcomes after TAVI. During a 3-year period, 780 patients with severe aortic stenosis underwent TAVI at our institute and had baseline BNP levels. We compared the high, mid, and low tertiles of BNP levels. TAVI end points, device success, and adverse events were considered according to the Valve Academic Research Consortium 2 definitions. Device success was significantly lower for patients with high BNP (98.1% vs 96.2% vs 91.9% for the low, mid, and high BNP tertiles, respectively; p = 0.003). All-cause mortality up to 30 days was 1.2% (3 of 260) versus 2.3% (6 of 260) versus 5% (13 of 260), respectively (p = 0.03). Six-month mortality rate was 4.1% (10 of 241) for the low BNP tertile, 5% (12 of 239) for the mid BNP tertile, and 17.1% (40 of 234) for the high BNP tertile (p <0.001). In the multivariate model, high tertile of baseline BNP was found to be significantly associated with all-cause mortality (hazard ratio 3.3, 95% confidence interval 1.64 to 6.48; p = 0.001). In conclusion, elevated BNP levels are associated with increased short-term and midterm mortality after TAVI. We recommend measurement of baseline BNP as part of risk stratification models for TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Péptido Natriurético Encefálico/sangre , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/sangre , Estenosis de la Válvula Aórtica/diagnóstico , California/epidemiología , Ecocardiografía Transesofágica , Femenino , Humanos , Imagenología Tridimensional , Masculino , Tomografía Computarizada Multidetector , Periodo Preoperatorio , Estudios Retrospectivos , Tasa de Supervivencia/tendencias , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA