Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 38
Filtrar
Más filtros

País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Eur Radiol ; 2024 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-38992107

RESUMEN

OBJECTIVES: The aim of this study was to introduce the blackbird sign as a fast, qualitative measure of early supraspinatus (SSP) muscle atrophy and to correlate the sign with quantitatively assessed muscle volume and intramuscular fat fraction (FF) in patients with full-thickness SSP tears. MATERIALS AND METHODS: The blackbird sign describes the asymmetric pattern of early SSP atrophy: on sagittal MR images, the supero-posterior contour of the muscle becomes concave, resembling the shape of a blackbird. MRIs of patients with full-thickness SSP tears were retrospectively reviewed for the presence of the blackbird and tangent signs. Patients were then divided into group 1: negative tangent sign and negative blackbird sign (n = 67), group 2: negative tangent sign and positive blackbird sign (n = 31), and group 3: positive tangent sign (n = 32). A 2-point Dixon sequence was acquired in all patients from which quantitative FF and muscle volumes were calculated. RESULTS: In total 130 patients (mean age 67 ± 11 years) were included. Mean SSP volume was significantly smaller in group 3 (15.8 ± 8.1 cm3) compared to group 2 (23.9 ± 7.0 cm3, p = 0.01) and group 1 (29.7 ± 9.1 cm3, p < 0.01). Significantly lower muscle volumes were also found in group 2 compared to group 1 (p = 0.02), confirming that the blackbird sign is able to identify early SSP atrophy. Mean FF in the SSP was significantly higher in group 3 (18.5 ± 4.4%) compared to group 2 (10.9 ± 4.7%, p < 0.01) and group 1 (6.1 ± 2.6%, p < 0.01). CONCLUSION: Visual assessment of early muscle atrophy of the SSP is feasible and reproducible using the blackbird sign, allowing the diagnosis of early SSP atrophy. CLINICAL RELEVANCE STATEMENT: In routine clinical practice, the blackbird sign may be a useful tool for assessing early muscle degeneration before the risk of postoperative rotator cuff re-tears increases with progressive muscle atrophy and fatty infiltration. KEY POINTS: Quantitative measurements of rotator cuff injuries require time, limiting clinical practicality. The proposed blackbird sign is able to identify early SSP atrophy. Reader agreement for the blackbird sign was substantial, demonstrating reproducibility and ease of implementation in the clinical routine.

2.
AJR Am J Roentgenol ; 222(1): e2329950, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37646386

RESUMEN

BACKGROUND. Photon-counting detector (PCD) CT could be useful to help address the typically high radiation doses of conventional energy-integrating detector (EID) CT of the lumbar spine. OBJECTIVE. The purpose of our study was to compare PCD CT and EID CT of the lumbar spine, both performed using tin filtration, in terms of radiation dose and image quality. METHODS. This study included a prospective sample of 39 patients (22 men, 17 women; mean age, 27.2 years) who underwent investigational PCD CT of the lumbar spine as part of a separate study and a retrospective sample of 39 patients (22 men, 17 women; mean age, 34.9 years) who underwent clinically indicated EID CT of the lumbar spine. In both groups, all examinations were performed using unenhanced technique with tin prefiltration between June 2022 and January 2023. Patients were matched between groups using age, sex, and BMI. A custom gaussian curve-fitting algorithm was used to automatically calculate image noise, SNR, and CNR for each examination, on the basis of all voxels within the image set. Three radiologists independently reviewed examinations to perform a subjective visual assessment of visualization of trabecular architecture, cortical bone, neuroforaminal content, paraspinal muscles, and intervertebral disk, as well as overall image quality, using a 4-point Likert scale (1 = poor, 4 = excellent). PCD CT and EID CT examinations were compared. RESULTS. Mean CTDIvol was 4.4 ± 1.0 (SD) mGy for PCD CT versus 11.1 ± 1.9 mGy for EID CT (p < .001). Mean size-specific dose estimate (SSDE) was 6.2 ± 1.0 (SD) mGy for PCD CT versus 14.2 ± 1.8 mGy for EID CT (p < .001). PCD CT and EID CT examinations were not significantly different in terms of image noise or SNR (both p > .05). PCD CT, in comparison with EID CT, showed significantly higher CNR (mean ± SD, 33.6 ± 3.3 vs 29.3 ± 4.1; p < .001). For all three readers, the median score for overall image quality was 4 (range, 3-4) for both PCD CT and EID CT. PCD CT and EID CT examinations showed no significant difference in terms of any qualitative measure for any reader (all p > .05). CONCLUSION. PCD CT, in comparison with EID CT, yielded significantly lower radiation dose with preserved image quality. CLINICAL IMPACT. The findings support expanded use of PCD CT for lumbar spine evaluation.


Asunto(s)
Fotones , Estaño , Masculino , Humanos , Femenino , Adulto , Estudios Prospectivos , Estudios Retrospectivos , Fantasmas de Imagen , Tomografía Computarizada por Rayos X/métodos , Dosis de Radiación
3.
AJR Am J Roentgenol ; 222(1): e2329765, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37646387

RESUMEN

BACKGROUND. Photon-counting detector (PCD) CT may allow lower radiation doses than used for conventional energy-integrating detector (EID) CT, with preserved image quality. OBJECTIVE. The purpose of this study was to compare PCD CT and EID CT, reconstructed with and without a denoising tool, in terms of image quality of the osseous pelvis in a phantom, with attention to low radiation doses. METHODS. A pelvic phantom comprising human bones in acrylic material mimicking soft tissue underwent PCD CT and EID CT at various tube potentials and radiation doses ranging from 0.05 to 5.00 mGy. Additional denoised reconstructions were generated using a commercial tool. Noise was measured in the acrylic material. Two readers performed independent qualitative assessments that entailed determining the denoised EID CT reconstruction with the lowest acceptable dose and then comparing this reference reconstruction with PCD CT reconstructions without and with denoising, using subjective Likert scales. RESULTS. Noise was lower for PCD CT than for EID CT. For instance, at 0.05 mGy and 100 kV with tin filter, noise was 38.4 HU for PCD CT versus 48.8 HU for EID CT. Denoising further reduced noise; for example, for PCD CT at 100 kV with tin filter at 0.25 mGy, noise was 19.9 HU without denoising versus 9.7 HU with denoising. For both readers, lowest acceptable dose for EID CT was 0.10 mGy (total score, 11 of 15 for both readers). Both readers somewhat agreed that PCD CT without denoising at 0.10 mGy (reflecting reference reconstruction dose) was relatively better than the reference reconstruction in terms of osseous structures, artifacts, and image quality. Both readers also somewhat agreed that denoised PCD CT reconstructions at 0.10 mGy and 0.05 mGy (reflecting matched and lower doses, respectively, with respect to reference reconstruction dose) were relatively better than the reference reconstruction for the image quality measures. CONCLUSION. PCD CT showed better-quality images than EID CT when performed at the lowest acceptable radiation dose for EID CT. PCD CT with denoising yielded better-quality images at a dose lower than lowest acceptable dose for EID CT. CLINICAL IMPACT. PCD CT with denoising could facilitate lower radiation doses for pelvic imaging.


Asunto(s)
Fotones , Estaño , Humanos , Tomografía Computarizada por Rayos X/métodos , Fantasmas de Imagen , Dosis de Radiación , Pelvis
4.
Eur Radiol ; 2023 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-37855854

RESUMEN

OBJECTIVES: This study aimed to evaluate the diagnostic accuracy, inter-reader agreement, and associated pathologies on MR images of patients with confirmed TC. METHODS AND MATERIALS: In this retrospective study, 168 ankle MRI exams were included, consisting of 56 patients with clinically or surgically confirmed TC and 112 controls without TC, matched for age and sex. Images were analyzed independently by three radiologists blinded to clinical information. The evaluation criteria included the presence, type, and location of TC, as well as associated pathologies. After calculating diagnostic accuracy and the odds ratio of demographic data and anatomic coalition type for associated pathologies, inter-reader agreement was assessed using kappa statistics. RESULTS: The majority of TCs were non-osseous (91.1%) and located at the calcaneonavicular (33.9%) or talocalcaneal joint (66.1%). Associated pathologies included adjacent and distant bone marrow edema (57.1% and 25.0%), osteochondral defect of the talar dome (OCD, 19.6%), and joint effusion (10.7%) and accessory anterolateral talar facet (17.9%). Talar OCD was associated with increased patient age (p = 0.03). MRI exhibited a cumulative sensitivity and specificity of 95.8% and 94.3% with almost perfect inter-reader agreement (κ = 0.895). CONCLUSION: MRI is a reliable method for detecting tarsal coalition and identifying commonly associated pathologies. Therefore, we recommend the routine use of MRI in the diagnostic workup of patients with foot pain and suspected tarsal coalition. CLINICAL RELEVANCE STATEMENT: MRI is an accurate and reliable modality for diagnosing tarsal coalitions and detecting associated pathologies, while improving patient safety compared to computed tomography by avoiding radiation exposure. KEY POINTS: • Despite the technological progress in magnetic resonance imaging (MRI), computed tomography (CT) is still regarded as the gold standard for diagnosing tarsal coalition (TC). • MRI had a cumulative sensitivity of 95.8% and specificity of 94.3% for detecting tarsal coalition with an almost perfect inter-reader agreement. • MRI demonstrates high accuracy and reliability in diagnosing tarsal coalitions and is useful for identifying associated pathologies, while also improving patient safety by avoiding radiation exposure.

5.
Eur Radiol ; 32(8): 5233-5245, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35267094

RESUMEN

OBJECTIVES: There is conflicting evidence about the comparative diagnostic accuracy of the Agatston score versus computed tomography angiography (CTA) in patients with suspected obstructive coronary artery disease (CAD). PURPOSE: To determine whether CTA is superior to the Agatston score in the diagnosis of CAD. METHODS: In total 2452 patients with stable chest pain and a clinical indication for invasive coronary angiography (ICA) for suspected CAD were included by the Collaborative Meta-analysis of Cardiac CT (COME-CCT) Consortium. An Agatston score of > 400 was considered positive, and obstructive CAD defined as at least 50% coronary diameter stenosis on ICA was used as the reference standard. RESULTS: Obstructive CAD was diagnosed in 44.9% of patients (1100/2452). The median Agatston score was 74. Diagnostic accuracy of CTA for the detection of obstructive CAD (81.1%, 95% confidence interval [CI]: 77.5 to 84.1%) was significantly higher than that of the Agatston score (68.8%, 95% CI: 64.2 to 73.1%, p < 0.001). Among patients with an Agatston score of zero, 17% (101/600) had obstructive CAD. Diagnostic accuracy of CTA was not significantly different in patients with low to intermediate (1 to < 100, 100-400) versus moderate to high Agatston scores (401-1000, > 1000). CONCLUSIONS: Results in our international cohort show CTA to have significantly higher diagnostic accuracy than the Agatston score in patients with stable chest pain, suspected CAD, and a clinical indication for ICA. Diagnostic performance of CTA is not affected by a higher Agatston score while an Agatston score of zero does not reliably exclude obstructive CAD. KEY POINTS: • CTA showed significantly higher diagnostic accuracy (81.1%, 95% confidence interval [CI]: 77.5 to 84.1%) for diagnosis of coronary artery disease when compared to the Agatston score (68.8%, 95% CI: 64.2 to 73.1%, p < 0.001). • Diagnostic performance of CTA was not affected by increased amount of calcium and was not significantly different in patients with low to intermediate (1 to <100, 100-400) versus moderate to high Agatston scores (401-1000, > 1000). • Seventeen percent of patients with an Agatston score of zero showed obstructive coronary artery disease by invasive angiography showing absence of coronary artery calcium cannot reliably exclude coronary artery disease.


Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Calcio , Dolor en el Pecho/diagnóstico por imagen , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Humanos , Valor Predictivo de las Pruebas , Tomografía Computarizada por Rayos X
6.
Emerg Radiol ; 28(4): 781-788, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33644833

RESUMEN

PURPOSE: To evaluate the ability of a semi-automated radiomic analysis software in predicting the likelihood of spontaneous passage of urinary stones compared with manual measurements. METHODS: Symptomatic patients visiting the emergency department with suspected stones in either kidney or ureters who underwent a CT scan were included. Patients were followed for up to 6 months for the outcome of a trial of passage. Maximum stone diameters in axial and coronal images were measured manually. Stone length, width, height, max diameter, volume, the mean and standard deviation of the Hounsfield units, and morphologic features were also measured using automated radiomic analysis software. Multivariate models were developed using these data to predict subsequent spontaneous stone passage, with results expressed as the area under a receiver operating curve (AUC). RESULTS: One hundred eighty-four patients (69 females) with a median age of 56 years were included. Spontaneous stone passage occurred in 114 patients (62%). Univariate analysis demonstrated an AUC of 0.83 and 0.82 for the maximum stone diameter determined manually in the axial and coronal planes, respectively. Multivariate models demonstrated an AUC of 0.82 for a model including manual measurement of maximum stone diameter in axial and coronal planes. The same AUC was found for a model including automatic measurement of maximum height and diameter of the stone. Further addition of morphological parameters measured automatically did not increase AUC beyond 0.83. CONCLUSION: The semi-automated radiomic analysis of urinary stones shows similar accuracy compared with manual measurements for predicting urinary stone passage. Further studies are needed to predict clinical impacts of reporting the likelihood of urinary stone passage and improving inter-observer variation using automatic radiomic analysis software.


Asunto(s)
Uréter , Cálculos Ureterales , Femenino , Humanos , Persona de Mediana Edad , Variaciones Dependientes del Observador , Probabilidad , Tomografía Computarizada por Rayos X
8.
Radiology ; 289(2): 436-442, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30084728

RESUMEN

Purpose To compare a research photon-counting-detector (PCD) CT scanner to a dual-source, dual-energy CT scanner for the detection and characterization of renal stones in human participants with known stones. Materials and Methods Thirty study participants (median age, 61 years; 10 women) underwent a clinical renal stone characterization scan by using dual-energy CT and a subsequent research PCD CT scan by using the same radiation dose (as represented by volumetric CT dose index). Two radiologists were tasked with detection of stones, which were later characterized as uric acid or non-uric acid by using a commercial dual-energy CT analysis package. Stone size and contrast-to-noise ratio were additionally calculated. McNemar odds ratios and Cohen k were calculated separately for all stones and small stones (≤3 mm). Results One-hundred sixty renal stones (91 stones that were ≤ 3 mm in axial length) were visually detected. Compared with 1-mm-thick routine images from dual-energy CT, the odds of detecting a stone at PCD CT were 1.29 (95% confidence interval: 0.48, 3.45) for all stones. Stone segmentation and characterization were successful at PCD CT in 70.0% (112 of 160) of stones versus 54.4% (87 of 160) at dual-energy CT, and was superior for stones 3 mm or smaller at PCD CT (45 vs 25 stones, respectively; P = .002). Stone characterization agreement between scanners for stones of all sizes was substantial (k = 0.65). Conclusion Photon-counting-detector CT is similar to dual-energy CT for helping to detect renal stones and is better able to help characterize small renal stones. © RSNA, 2018.


Asunto(s)
Cálculos Renales/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Riñón/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Fotones , Estudios Prospectivos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Relación Señal-Ruido , Tomografía Computarizada por Rayos X/instrumentación
10.
Magn Reson Med ; 73(3): 1206-15, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24687430

RESUMEN

PURPOSE: To investigate and compare several quantification methods of myocardial perfusion measurements, paying special attention to the relation between the techniques and the required measurement duration. METHODS: Seven patients underwent contrast-enhanced rest and stress cardiac perfusion measurements at 3T. Three slices were acquired in each patient and were divided into 16 segments, leading to 112 rest and stress data curves, which were analyzed using various tracer kinetic models as well as a model-free deconvolution. Plasma flow, plasma volume, and myocardial perfusion reserve were analyzed for the complete acquisition as well as for the first pass data only. RESULTS: Deconvolution analysis yielded stable results for both rest and stress analysis, while Fermi and one compartment models agree well for first pass data (rest measurements only) and prolonged data acquisition (stress measurements only). More complex models do not yield satisfactory results for the short measurement times investigated in this study. CONCLUSIONS: When performing MRI-based quantification of myocardial perfusion, care must be taken that the method used is appropriate for the time frame under investigation. When a numerical deconvolution is used instead of tracer kinetic models, more stable results are obtained.


Asunto(s)
Enfermedad de la Arteria Coronaria/metabolismo , Circulación Coronaria , Angiografía por Resonancia Magnética/métodos , Modelos Cardiovasculares , Imagen de Perfusión Miocárdica/métodos , Compuestos Organometálicos/farmacocinética , Anciano , Algoritmos , Velocidad del Flujo Sanguíneo , Simulación por Computador , Medios de Contraste/farmacocinética , Enfermedad de la Arteria Coronaria/diagnóstico , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Cinética , Masculino , Tasa de Depuración Metabólica , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
11.
Eur Radiol ; 24(1): 191-9, 2014 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24013818

RESUMEN

OBJECTIVES: To evaluate the performance of three-dimensional semi-automated evaluation software for the assessment of myocardial blood flow (MBF) and blood volume (MBV) at dynamic myocardial perfusion computed tomography (CT). METHODS: Volume-based software relying on marginal space learning and probabilistic boosting tree-based contour fitting was applied to CT myocardial perfusion imaging data of 37 subjects. In addition, all image data were analysed manually and both approaches were compared with SPECT findings. Study endpoints included time of analysis and conventional measures of diagnostic accuracy. RESULTS: Of 592 analysable segments, 42 showed perfusion defects on SPECT. Average analysis times for the manual and software-based approaches were 49.1 ± 11.2 and 16.5 ± 3.7 min respectively (P < 0.01). There was strong agreement between the two measures of interest (MBF, ICC = 0.91, and MBV, ICC = 0.88, both P < 0.01) and no significant difference in MBF/MBV with respect to diagnostic accuracy between the two approaches for both MBF and MBV for manual versus software-based approach; respectively; all comparisons P > 0.05. CONCLUSIONS: Three-dimensional semi-automated evaluation of dynamic myocardial perfusion CT data provides similar measures and diagnostic accuracy to manual evaluation, albeit with substantially reduced analysis times. This capability may aid the integration of this test into clinical workflows. KEY POINTS: • Myocardial perfusion CT is attractive for comprehensive coronary heart disease assessment. • Traditional image analysis methods are cumbersome and time-consuming. • Automated 3D perfusion software shortens analysis times. • Automated 3D perfusion software increases standardisation of myocardial perfusion CT. • Automated, standardised analysis fosters myocardial perfusion CT integration into clinical practice.


Asunto(s)
Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico , Imagenología Tridimensional/métodos , Imagen de Perfusión Miocárdica , Programas Informáticos , Tomografía Computarizada de Emisión de Fotón Único/métodos , Tomografía Computarizada por Rayos X/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos
12.
AJR Am J Roentgenol ; 203(2): W174-80, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24848691

RESUMEN

OBJECTIVE: The purpose of this study was to determine the feasibility of global quantitative measurements of left ventricular myocardial perfusion derived from stress dynamic CT myocardial perfusion imaging. MATERIALS AND METHODS: The coronary CT angiographic and CT myocardial perfusion imaging datasets of 146 patients were visually evaluated for the presence of coronary artery stenosis and perfusion defects. For the quantitative analysis, volumes of interest were defined over the entire left ventricular myocardium to obtain global myocardial blood flow (MBF), myocardial blood volume (MBV), and volume transfer constant (K(trans)). RESULTS: In patients without anatomically significant coronary stenosis or perfusion defects, the mean value of global MBF was 137.9 ± 28.8 mL/100 mL/min; MBV, 19.5 ± 2.3 mL/100 mL; and K(trans), 85.8 ± 15.2 mL/100 mL/min. In patients with perfusion defects in one, two, or three vessels, the mean global MBF values were 132.6 ± 29.2, 117.4 ± 4.9, and 92.5 ± 11.2 mL/100 mL/min; MBV, 17.9 ± 3.2, 16.1 ± 3.1, and 12.8 ± 1.7 mL/100 mL; and K(trans), 80.4 ± 12.9, 76.6 ± 13.8, and 72.6 ± 15.5 mL/100 mL/min. In patients with significant (> 50%) stenosis in one, two, or three vessels at coronary CT angiography, the mean global MBF values were 129.2 ± 28.3, 120.5 ± 24.2, and 119.4 ± 33.5 mL/100 mL/min; MBV, 17.8 ± 3.3, 17.2 ± 3.2, and 14.7 ± 4.1 mL/100 mL; and K(trans), 80.3 ± 12.9, 76.0 ± 14.7, and 77.6 ± 13.2 mL/100 mL/min. CONCLUSION: Global quantitative assessment of left ventricular perfusion with stress dynamic CT myocardial perfusion imaging is feasible, and the findings correlate with the visual assessment of perfusion and the presence of coronary artery stenosis at coronary CT angiography. The potential clinical utility of this technique as a diagnostic tool for differentiating normal from globally reduced myocardial perfusion or as a prognostic marker merits further investigation.


Asunto(s)
Estenosis Coronaria/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Anciano , Técnicas de Imagen Sincronizada Cardíacas , Medios de Contraste , Angiografía Coronaria , Circulación Coronaria , Estudios de Factibilidad , Femenino , Humanos , Imagenología Tridimensional , Yohexol/análogos & derivados , Masculino , Persona de Mediana Edad , Sistema de Registros , Estudios Retrospectivos
13.
Invest Radiol ; 59(4): 328-336, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-37707864

RESUMEN

OBJECTIVES: The aim of this study was to quantify and compare fat fraction (FF) and muscle volume between patients with failed and intact rotator cuff (RC) repair as well as a control group with nonsurgical conservative treatment to define FF cutoff values for predicting the outcome of RC repair. MATERIALS AND METHODS: Patients with full-thickness RC tears who received magnetic resonance imaging (MRI) before and after RC repair including a 2-point Dixon sequence were retrospectively screened. Patients with retear of 1 or more tendons diagnosed on MRI (Sugaya IV-V) were enrolled and matched to patients with intact RC repair (Sugaya I-II) and to a third group with conservatively treated RC tears. Two radiologists evaluated morphological features (Cofield, Patte, and Goutallier), as well as the integrity of the RC after repair (Sugaya). Fat fractions were calculated from the 2-point Dixon sequence, and the RC muscles were segmented semiautomatically to calculate FFs and volume for each muscle. Receiver operator characteristics curves were used to determine FF cutoff values that best predict RC retears. RESULTS: In total, 136 patients were enrolled, consisting of 3 groups: 41 patients had a failed RC repair (58 ± 7 years, 16 women), 50 patients matched into the intact RC repair group, and 45 patients were matched into the conservative treatment group. Receiver operator characteristics curves showed reliable preoperative FF cutoff values for predicting retears at 6.0% for the supraspinatus muscle (0.83 area under the curve [AUC]), 7.4% for the infraspinatus muscle (AUC 0.82), and 8.3% for the subscapularis muscle (0.94 AUC). CONCLUSIONS: Preoperative quantitative FF calculated from 2-point Dixon MRI can be used to predict the risk of retear after arthroscopic RC repair with cutoff values between 6% and 8.3%.


Asunto(s)
Lesiones del Manguito de los Rotadores , Manguito de los Rotadores , Humanos , Femenino , Manguito de los Rotadores/diagnóstico por imagen , Manguito de los Rotadores/cirugía , Manguito de los Rotadores/patología , Estudios Retrospectivos , Lesiones del Manguito de los Rotadores/diagnóstico por imagen , Lesiones del Manguito de los Rotadores/cirugía , Lesiones del Manguito de los Rotadores/patología , Tendones , Imagen por Resonancia Magnética/métodos , Resultado del Tratamiento
14.
Invest Radiol ; 59(8): 545-553, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38214560

RESUMEN

OBJECTIVES: The aim of this study was to compare the effectiveness and clinical utility of virtual monoenergetic image (VMI) reconstructions in computed tomography (CT) scans with and without tin prefiltration on a photon-counting detector (PCD) CT system to reduce metal implant artifacts in the postoperative ankle. MATERIALS AND METHODS: This retrospective study included patients with internal fixation of the ankle scanned with and without tin prefiltration (Sn) on a PCD CT scanner between March and October 2023. Virtual monoenergetic images between 60 and 190 keV were reconstructed with a 10-keV increment in a bone kernel for both acquisitions (VMI Sn and VMI Std , respectively). Noise measurements assessed artifact reduction in the most prominent near-metal image distortions and were compared between acquisitions modes as well as between polychromatic images and VMIs. Three readers assessed the visibility of osseous healing along with interpretability and artifact extent for 5 reconstruction levels. RESULTS: A total of 48 patients (21 females, 27 males; mean age, 55.1 ± 19.4 years) were included in this study. Tin-prefiltered acquisitions (n = 30) had a lower artifact level for polychromatic images and VMIs compared with non-tin-prefiltered acquisitions (n = 18; P ≤ 0.043). A significant reduction of metal artifacts was observed for VMI Sn ≥120 keV compared with polychromatic images (hyperdense artifacts: 40.2 HU [interquartile range (IQR) 39.8] vs 14.0 HU [IQR 11.1]; P ≤ 0.01 and hypodense artifacts: 91.2 HU [IQR 82.4] vs 29.7 HU [IQR 39.6]; P ≤ 0.001). For VMI Std , this applied to reconstructions ≥100 keV (hyperdense artifacts: 57.7 HU [IQR 33.4] vs 19.4 HU [IQR 27.6]; P ≤ 0.001 and hypodense artifacts: 106.9 HU [IQR 76.1] vs 57.4 HU [IQR 55.7]; P ≤ 0.021). For visibility of osseous healing, VMI Sn at 120 keV yielded higher ratings compared with polychromatic images ( P ≤ 0.001), whereas image interpretability was rated better ( P = 0.023), and artifact extent was rated lower ( P ≤ 0.001) compared with polychromatic images. CONCLUSIONS: Tin-prefiltered VMI at 120 keV showed a significant reduction in metal artifacts compared with polychromatic images, whereas visibility of osseous healing and image interpretability was improved. Therefore, tin-prefiltration PCD CT with VMI reconstructions may be a helpful complement to postsurgical CT imaging of the ankle in patients with metal implants.


Asunto(s)
Artefactos , Tomografía Computarizada por Rayos X , Humanos , Femenino , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Adulto , Estaño , Anciano , Fotones , Metales , Articulación del Tobillo/diagnóstico por imagen , Articulación del Tobillo/cirugía
15.
JOR Spine ; 7(2): e1330, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38585427

RESUMEN

Introduction: The emerging field of the disc microbiome challenges traditional views of disc sterility, which opens new avenues for novel clinical insights. However, the lack of methodological consensus in disc microbiome studies introduces discrepancies. The aims of this study were to (1) compare the disc microbiome of non-Modic (nonMC), Modic type 1 change (MC1), and MC2 discs to findings from prior disc microbiome studies, and (2) investigate if discrepancies to prior studies can be explained with bioinformatic variations. Methods: Sequencing of 16S rRNA in 70 discs (24 nonMC, 25 MC1, and 21 MC2) for microbiome profiling. The experimental setup included buffer contamination controls and was performed under aseptic conditions. Methodology and results were contrasted with previous disc microbiome studies. Critical bioinformatic steps that were different in our best-practice approach and previous disc microbiome studies (taxonomic lineage assignment, prevalence cut-off) were varied and their effect on results were compared. Results: There was limited overlap of results with a previous study on MC disc microbiome. No bacterial genera were shared using the same bioinformatic parameters. Taxonomic lineage assignment using "amplicon sequencing variants" was more sensitive and detected 48 genera compared to 22 with "operational taxonomic units" (previous study). Increasing filter cut-off from 4% to 50% (previous study) reduced genera from 48 to 4 genera. Despite these differences, both studies observed dysbiosis with an increased abundance of gram-negative bacteria in MC discs as well as a lower beta-diversity. Cutibacterium was persistently detected in all groups independent of the bioinformatic approach, emphasizing its prevalence. Conclusion: There is dysbiosis in MC discs. Bioinformatic parameters impact results yet cannot explain the different findings from this and a previous study. Therefore, discrepancies are likely caused by different sample preparations or true biologic differences. Harmonized protocols are required to advance understanding of the disc microbiome and its clinical implications.

16.
Radiology ; 269(3): 730-7, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-24023074

RESUMEN

PURPOSE: To study the predictive value of whole-body magnetic resonance (MR) imaging for the occurrence of cardiac and cerebrovascular events in a cohort of patients with diabetes mellitus (DM). MATERIALS AND METHODS: This HIPAA-compliant study was approved by the institutional review board. Informed consent was obtained from all patients before enrollment into the study. The authors followed up 65 patients with DM (types 1 and 2) who underwent a comprehensive, contrast material-enhanced whole-body MR imaging protocol, including brain, cardiac, and vascular sequences at baseline. Follow-up was performed by phone interview. The primary endpoint was a major adverse cardiac and cerebrovascular event (MACCE), which was defined as composite cardiac-cerebrovascular death, myocardial infarction, cerebrovascular event, or revascularization. MR images were assessed for the presence of systemic atherosclerotic vessel changes, white matter lesions, and myocardial changes. Kaplan-Meier survival and Cox regression analyses were performed to determine associations. RESULTS: Follow-up was completed in 61 patients (94%; median age, 67.5 years; 30 women [49%]; median follow-up, 70 months); 14 of the 61 patients (23%) experienced MACCE. Although normal whole-body MR imaging excluded MACCE during the follow-up period (0%; 95% confidence interval [CI]: 0%, 17%), any detectable ischemic and/or atherosclerotic changes at whole-body MR imaging (prevalence, 66%) conferred a cumulative event rate of 20% at 3 years and 35% at 6 years. Whole-body MR imaging summary estimate of disease was strongly predictive for MACCE (one increment of vessel score and each territory with atherosclerotic changes: hazard ratio, 13.2 [95% CI: 4.5, 40.1] and 3.9 [95% CI: 2.2, 7.5], respectively), also beyond clinical characteristics as well as individual cardiac or cerebrovascular MR findings. CONCLUSION: These initial data indicate that disease burden as assessed with whole-body MR imaging confers strong prognostic information in patients with DM. Online supplemental material is available for this article.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico , Trastornos Cerebrovasculares/diagnóstico , Complicaciones de la Diabetes/diagnóstico , Imagen por Resonancia Magnética/métodos , Imagen de Cuerpo Entero , Anciano , Medios de Contraste , Determinación de Punto Final , Femenino , Estudios de Seguimiento , Humanos , Entrevistas como Asunto , Masculino , Valor Predictivo de las Pruebas , Pronóstico , Estudios Prospectivos , Riesgo
17.
Phys Med Biol ; 68(19)2023 10 05.
Artículo en Inglés | MEDLINE | ID: mdl-37733068

RESUMEN

Objective.Reducing CT radiation dose is an often proposed measure to enhance patient safety, which, however results in increased image noise, translating into degradation of clinical image quality. Several deep learning methods have been proposed for low-dose CT (LDCT) denoising. The high risks posed by possible hallucinations in clinical images necessitate methods which aid the interpretation of deep learning networks. In this study, we aim to use qualitative reader studies and quantitative radiomics studies to assess the perceived quality, signal preservation and statistical feature preservation of LDCT volumes denoised by deep learning. We aim to compare interpretable deep learning methods with classical deep neural networks in clinical denoising performance.Approach.We conducted an image quality analysis study to assess the image quality of the denoised volumes based on four criteria to assess the perceived image quality. We subsequently conduct a lesion detection/segmentation study to assess the impact of denoising on signal detectability. Finally, a radiomic analysis study was performed to observe the quantitative and statistical similarity of the denoised images to standard dose CT (SDCT) images.Main results.The use of specific deep learning based algorithms generate denoised volumes which are qualitatively inferior to SDCT volumes(p< 0.05). Contrary to previous literature, denoising the volumes did not reduce the accuracy of the segmentation (p> 0.05). The denoised volumes, in most cases, generated radiomics features which were statistically similar to those generated from SDCT volumes (p> 0.05).Significance.Our results show that the denoised volumes have a lower perceived quality than SDCT volumes. Noise and denoising do not significantly affect detectability of the abdominal lesions. Denoised volumes also contain statistically identical features to SDCT volumes.


Asunto(s)
Aprendizaje Profundo , Humanos , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Redes Neurales de la Computación , Algoritmos , Procesamiento de Imagen Asistido por Computador/métodos , Relación Señal-Ruido
18.
Radiology ; 260(3): 689-98, 2011 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-21846761

RESUMEN

PURPOSE: To determine the feasibility of computed tomography (CT)-based dynamic myocardial perfusion imaging for the detection of hemodynamically significant coronary artery stenosis, as defined with fractional flow reserve (FFR). MATERIALS AND METHODS: Institutional review board approval and informed patient consent were obtained before patient enrollment in the study. The study was HIPAA compliant. Subjects who were suspected of having or were known to have coronary artery disease underwent electrocardiographically triggered dynamic stress myocardial perfusion imaging. FFR measurement was performed within all main coronary arteries with a luminal narrowing of 50%-85%. Estimated myocardial blood flow (MBF) was derived from CT images by using a model-based parametric deconvolution method for 16 myocardial segments and was related to hemodynamically significant coronary artery stenosis with an FFR of 0.75 or less in a blinded fashion. Conventional measures of diagnostic accuracy were derived, and discriminatory power analysis was performed by using logistic regression analysis. RESULTS: Of 36 enrolled subjects, 33 (mean age, 68.1 years ± 10 [standard deviation]; 25 [76%] men, eight [24%] women) completed the study protocol. An MBF cut point of 75 mL/100 mL/min provided the highest discriminatory power (C statistic, 0.707; P <.001). While the diagnostic accuracy of CT for the detection of anatomically significant coronary artery stenosis (>50%) was high, it was low for the detection of hemodynamically significant stenosis (positive predictive value [PPV] per coronary segment, 49%; 95% confidence interval [CI]: 36%, 60%). With use of estimated MBF to reclassify lesions depicted with CT angiography, 30 of 70 (43%) coronary lesions were graded as not hemodynamically significant, which significantly increased PPV to 78% (95% CI: 61%, 89%; P = .02). The presence of a coronary artery stenosis with a corresponding MBF less than 75 mL/100 mL/min had a high risk for hemodynamic significance (odds ratio, 86.9; 95% CI:17.6, 430.4). CONCLUSION: Dynamic CT-based stress myocardial perfusion imaging may allow detection of hemodynamically significant coronary artery stenosis.


Asunto(s)
Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Imagen de Perfusión Miocárdica/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Estudios de Factibilidad , Femenino , Reserva del Flujo Fraccional Miocárdico , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
19.
J Cardiovasc Comput Tomogr ; 14(6): 502-509, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32253123

RESUMEN

OBJECTIVES: To obtain 3D CT measurements of mitral annulus throughout cardiac cycle using prototype mitral modeling software, assess interobserver agreement, and compare among patients with mitral prolapse (MP) and control group. BACKGROUND: Pre-procedural imaging is critical for planning of transcatheter mitral valve (MV) replacement. However, there is limited data regarding reliable CT-based measurements to accurately characterize the dynamic geometry of the mitral annulus in patients with MV disease. METHODS: Patients with MP and control subjects without any MV disease who underwent ECG-gated cardiac CT were retrospectively identified. Multiphasic CT data was loaded into a prototype mitral modeling software. Multiple anatomical parameters in 3D space were recorded throughout the cardiac cycle (0-95%): annular circumference, planar-surface-area (PSA), anterior-posterior (A-P) distance, and anterolateral-posteromedial (AL-PM) distance. Comparisons were made among the two groups, with p < 0.05 considered statistically significant. Interobserver agreement was assessed on ten patients using intraclass correlation coefficient (ICC) among 4 experienced readers. RESULTS: A total of 100 subjects were included: 50 with MP and 50 control. Annular dimensions were significantly higher in the MP group than control group, with circumference (144 ± 11 vs. 117±8 mm), PSA (1533 ± 247 vs. 1005 ± 142 mm2), A-P distance (38 ± 4 vs. 32±2 mm), and AL-PM distance (47 ± 4 vs. 39±3 mm) (all p < 0.001). Substantial size changes were observed throughout the cardiac cycle, but with maximal and minimal sizes at different cardiac phases for the two groups. The interobserver agreement was excellent (ICC≥0.75) for annular circumference, PSA, A-P- and AL-PM distance. CONCLUSION: A significant variation in the mitral annular measures between different cardiac phases and two groups was observed with excellent interobserver agreement.


Asunto(s)
Angiografía por Tomografía Computarizada , Angiografía Coronaria , Prolapso de la Válvula Mitral/diagnóstico por imagen , Válvula Mitral/diagnóstico por imagen , Adulto , Anciano , Técnicas de Imagen Sincronizada Cardíacas , Electrocardiografía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Válvula Mitral/fisiopatología , Prolapso de la Válvula Mitral/fisiopatología , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos
20.
Abdom Radiol (NY) ; 45(3): 623-631, 2020 03.
Artículo en Inglés | MEDLINE | ID: mdl-31980866

RESUMEN

PURPOSE: To determine how small bowel neuroendocrine neoplasms (SBNEN's) are diagnosed and examine the effect of CT enterography (CTE) on diagnosis and rates of disease-free survival. METHODS: Histopathologically-confirmed SBNEN's diagnosed at our institution between 1996 and 2016 were identified. Clinical presentation, radiology, endoscopy, surgery, and pathology reports were reviewed and compared between consecutive 5-year periods. RESULTS: Of the 178 SBNEN initially diagnosed at our institution, the incidence increased 12-fold from 9 (during 1996-2000) to 114 (during 2011-2016). Comparing the first 5 to the last 5 years, GI bleeding and abdominal pain increased significantly as indications (with both increasing from 0 to > 25%, p ≤ 0.023). Initial diagnosis by radiology increased 2-fold [from 33% (n = 3) to 66% (n = 75); p = 0.263]. Detection of a small bowel mass and the suggestion that SBNEN was present varied significantly between imaging modalities (p < 0.0001; CTE - 95% (52/55) and 91% (50/55) vs. abdominal CT 45% (37/85) and 35% (29/85), respectively). Recurrence rates increased with SBNEN size (p = 0.012; e.g., of SBNEN diagnosed by endoscopy, 18% of SBNEN measuring 0.6 ± 0.3 cm recurred vs. 75% measuring 3.7 ± 1.0 cm). Rates of disease-free survival, and the incidence of local and liver metastases were decreased when tumors were first identified by CTE rather than other CT/MR imaging modalities (p = 0.0034, 0.0475, and 0.0032, respectively). CONCLUSION: There has been a dramatic increase in SBNENs detected by CTE and endoscopy over the last 20 years. SBNEN's detected by CTE and small tumors detected at endoscopy have longer disease-free survival after surgical resection.


Asunto(s)
Neoplasias Intestinales/diagnóstico por imagen , Intestino Delgado/diagnóstico por imagen , Tumores Neuroendocrinos/diagnóstico por imagen , Anciano , Supervivencia sin Enfermedad , Endoscopía Gastrointestinal , Femenino , Humanos , Neoplasias Intestinales/patología , Intestino Delgado/patología , Masculino , Persona de Mediana Edad , Tumores Neuroendocrinos/patología , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA