RESUMEN
OBJECTIVES AND BACKGROUND: This study aims to evaluate whether the high correlation and classification agreement of the instantaneous wave-free ratio (iFR) and the resting distal coronary to aortic pressure ratio (Pd /Pa ) with the fractional flow reserve (FFR) can be confirmed in stent-jailed side branches (J-SB). METHODS: Consecutive patients (n = 49) undergoing provisional stenting were prospectively enrolled and a physiological assessment of the J-SB (n = 51) was performed. FFR, iFR, and Pd /Pa were measured and the hemodynamic relevance was determined using cutoff values of ≤0.80, ≤0.89, and ≤0.92, respectively. RESULTS: Both iFR (r = 0.75) and Pd /Pa (r = 0.77) correlated closely with FFR. Classification agreement with FFR was 78% for iFR (81% sensitivity, 77% specificity) and 75% for Pd /Pa (63% sensitivity and 80% specificity). However, angiographic diameter stenosis and pressure indices correlated poorly. For a threshold of ≥70% stenosis, agreement concerning hemodynamic relevance was found in 59% for FFR, 69% for iFR, and 61% for Pd /Pa . CONCLUSION: As reported for other lesion types, FFR and the adenosine-independent pressure indices iFR and Pd /Pa show close correlation and a high classification agreement of approximately 75%-80% in J-SB. Therefore, iFR can be regarded as a recommendable alternative to FFR for the guidance of provisional stenting in bifurcation lesions.
Asunto(s)
Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Hiperemia , Adenosina , Cateterismo Cardíaco , Constricción Patológica , Angiografía Coronaria , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Reserva del Flujo Fraccional Miocárdico/fisiología , Humanos , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad , Stents , Resultado del TratamientoRESUMEN
OBJECTIVES: We evaluated the influence of image reconstruction kernels on the diagnostic accuracy of CT-derived fractional flow reserve (FFRCT) compared to invasive FFR in patients with coronary artery disease. METHODS: Sixty-nine patients, in whom coronary CT angiography was performed and who were further referred for invasive coronary angiography with FFR measurement via pressure wire, were retrospectively included. CT data sets were acquired using a third-generation dual-source CT system and rendered with medium smooth (Bv40) and sharp (Bv49) reconstruction kernels. FFRCT was calculated on-site using prototype software. Coronary stenoses with invasive FFR ≤ 0.80 were classified as significant. Agreement between FFRCT and invasive FFR was determined for both reconstruction kernels. RESULTS: One hundred analyzed vessels in 69 patients were included. Twenty-five vessels were significantly stenosed according to invasive FFR. Using a sharp reconstruction kernel for FFRCT resulted in a significantly higher correlation with invasive FFR (r = 0.74, p < 0.01 vs. r = 0.58, p < 0.01; p = 0.04) and a higher AUC in ROC curve analysis to correctly identify/exclude significant stenosis (AUC = 0.92 vs. AUC = 0.82 for sharp vs. medium smooth kernel, respectively, p = 0.02). A FFRCT value of ≤ 0.8 using a sharp reconstruction kernel showed a sensitivity of 88% and a specificity of 92% for detecting ischemia-causing lesions, resulting in a diagnostic accuracy of 91%. The medium smooth reconstruction kernel performed worse (sensitivity 60%, specificity 89%, accuracy 82%). CONCLUSION: Compared to invasively measured FFR, FFRCT using a sharp image reconstruction kernel shows higher diagnostic accuracy for detecting lesions causing ischemia, potentially altering decision-making in a clinical setting. KEY POINTS: ⢠Image reconstruction parameters influence the diagnostic accuracy of simulated fractional flow reserve derived from coronary computed tomography angiography. ⢠Using a sharp kernel image reconstruction algorithm delivers higher diagnostic accuracy compared to medium smooth kernel image reconstruction (gold standard invasive fractional flow reserve).
Asunto(s)
Enfermedad de la Arteria Coronaria , Estenosis Coronaria , Reserva del Flujo Fraccional Miocárdico , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estenosis Coronaria/diagnóstico por imagen , Vasos Coronarios , Humanos , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Índice de Severidad de la Enfermedad , Tomografía Computarizada por Rayos XRESUMEN
Radial access is recommended for percutaneous coronary intervention (PCI), but rotational atherectomy remains frequently performed via femoral access. Analyzing the procedural parameters, success rate and complications of rotational atherectomy, performed via radial in comparison to femoral access. We retrospectively analyzed 427 consecutive patients undergoing rotational atherectomy. Procedural parameters and outcome were determined in 171 patients, scheduled for radial and compared to 256 patients with femoral access use. In the radial access group (74 ± 9 years, 84% male), the LAD was most frequently treated (49%). Sheath size was 7F in 59% and 6F in 41%, burr size was 1.5 mm in 46% and 1.25 mm in 14% of patients. A temporary pacemaker was inserted in 14%. Procedural success rate stood at 97%. Access site complications occurred in 4% of patients, which was significantly less frequent than in in 256 patients treated via femoral access (13% p = 0.003). Compared to radial access, femoral access was associated with the use of larger sheaths (p < 0.001), more frequent treatment of non-LAD vessels (58.2% vs. 44.4%, p = 0.013) and a higher rate of temporary pacemaker use (27%; p = 0.001). No differences could be seen in procedural success (p = 0.83) and burr size (p = 0.51). Femoral access (OR 3.33; 95% CI 1.40-7.93), and female sex (OR3.40 95% CI 1.69-6.63) were independent predictors for access site complications. For coronary rotational atherectomy, radial access has a high success rate with overall use of smaller sheaths, but of equally sized burrs as well as a significant lower rate of access site-related complications than femoral access.
Asunto(s)
Aterectomía Coronaria , Intervención Coronaria Percutánea , Aterectomía Coronaria/efectos adversos , Femenino , Arteria Femoral , Humanos , Masculino , Intervención Coronaria Percutánea/efectos adversos , Arteria Radial , Estudios Retrospectivos , Resultado del TratamientoRESUMEN
BACKGROUND: Coronary inflammation induces dynamic changes in the balance between water and lipid content in perivascular adipose tissue (PVAT), as captured by perivascular Fat Attenuation Index (FAI) in standard coronary CT angiography (CCTA). However, inflammation is not the only process involved in atherogenesis and we hypothesized that additional radiomic signatures of adverse fibrotic and microvascular PVAT remodelling, may further improve cardiac risk prediction. METHODS AND RESULTS: We present a new artificial intelligence-powered method to predict cardiac risk by analysing the radiomic profile of coronary PVAT, developed and validated in patient cohorts acquired in three different studies. In Study 1, adipose tissue biopsies were obtained from 167 patients undergoing cardiac surgery, and the expression of genes representing inflammation, fibrosis and vascularity was linked with the radiomic features extracted from tissue CT images. Adipose tissue wavelet-transformed mean attenuation (captured by FAI) was the most sensitive radiomic feature in describing tissue inflammation (TNFA expression), while features of radiomic texture were related to adipose tissue fibrosis (COL1A1 expression) and vascularity (CD31 expression). In Study 2, we analysed 1391 coronary PVAT radiomic features in 101 patients who experienced major adverse cardiac events (MACE) within 5 years of having a CCTA and 101 matched controls, training and validating a machine learning (random forest) algorithm (fat radiomic profile, FRP) to discriminate cases from controls (C-statistic 0.77 [95%CI: 0.62-0.93] in the external validation set). The coronary FRP signature was then tested in 1575 consecutive eligible participants in the SCOT-HEART trial, where it significantly improved MACE prediction beyond traditional risk stratification that included risk factors, coronary calcium score, coronary stenosis, and high-risk plaque features on CCTA (Δ[C-statistic] = 0.126, P < 0.001). In Study 3, FRP was significantly higher in 44 patients presenting with acute myocardial infarction compared with 44 matched controls, but unlike FAI, remained unchanged 6 months after the index event, confirming that FRP detects persistent PVAT changes not captured by FAI. CONCLUSION: The CCTA-based radiomic profiling of coronary artery PVAT detects perivascular structural remodelling associated with coronary artery disease, beyond inflammation. A new artificial intelligence (AI)-powered imaging biomarker (FRP) leads to a striking improvement of cardiac risk prediction over and above the current state-of-the-art.
Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Perfilación de la Expresión Génica/métodos , Aprendizaje Automático , Placa Aterosclerótica/diagnóstico por imagen , Transcriptoma , Tejido Adiposo/patología , Anciano , Algoritmos , Estudios de Casos y Controles , Enfermedad de la Arteria Coronaria/genética , Enfermedad de la Arteria Coronaria/patología , Femenino , Estudios de Seguimiento , Marcadores Genéticos , Humanos , Masculino , Persona de Mediana Edad , Fenotipo , Placa Aterosclerótica/genética , Placa Aterosclerótica/patología , Medición de RiesgoRESUMEN
BACKGROUND: Coronary artery inflammation inhibits adipogenesis in adjacent perivascular fat. A novel imaging biomarker-the perivascular fat attenuation index (FAI)-captures coronary inflammation by mapping spatial changes of perivascular fat attenuation on coronary computed tomography angiography (CTA). However, the ability of the perivascular FAI to predict clinical outcomes is unknown. METHODS: In the Cardiovascular RISk Prediction using Computed Tomography (CRISP-CT) study, we did a post-hoc analysis of outcome data gathered prospectively from two independent cohorts of consecutive patients undergoing coronary CTA in Erlangen, Germany (derivation cohort) and Cleveland, OH, USA (validation cohort). Perivascular fat attenuation mapping was done around the three major coronary arteries-the proximal right coronary artery, the left anterior descending artery, and the left circumflex artery. We assessed the prognostic value of perivascular fat attenuation mapping for all-cause and cardiac mortality in Cox regression models, adjusted for age, sex, cardiovascular risk factors, tube voltage, modified Duke coronary artery disease index, and number of coronary CTA-derived high-risk plaque features. FINDINGS: Between 2005 and 2009, 1872 participants in the derivation cohort underwent coronary CTA (median age 62 years [range 17-89]). Between 2008 and 2016, 2040 patients in the validation cohort had coronary CTA (median age 53 years [range 19-87]). Median follow-up was 72 months (range 51-109) in the derivation cohort and 54 months (range 4-105) in the validation cohort. In both cohorts, high perivascular FAI values around the proximal right coronary artery and left anterior descending artery (but not around the left circumflex artery) were predictive of all-cause and cardiac mortality and correlated strongly with each other. Therefore, the perivascular FAI measured around the right coronary artery was used as a representative biomarker of global coronary inflammation (for prediction of cardiac mortality, hazard ratio [HR] 2·15, 95% CI 1·33-3·48; p=0·0017 in the derivation cohort, and 2·06, 1·50-2·83; p<0·0001 in the validation cohort). The optimum cutoff for the perivascular FAI, above which there is a steep increase in cardiac mortality, was ascertained as -70·1 Hounsfield units (HU) or higher in the derivation cohort (HR 9·04, 95% CI 3·35-24·40; p<0·0001 for cardiac mortality; 2·55, 1·65-3·92; p<0·0001 for all-cause mortality). This cutoff was confirmed in the validation cohort (HR 5·62, 95% CI 2·90-10·88; p<0·0001 for cardiac mortality; 3·69, 2·26-6·02; p<0·0001 for all-cause mortality). Perivascular FAI improved risk discrimination in both cohorts, leading to significant reclassification for all-cause and cardiac mortality. INTERPRETATION: The perivascular FAI enhances cardiac risk prediction and restratification over and above current state-of-the-art assessment in coronary CTA by providing a quantitative measure of coronary inflammation. High perivascular FAI values (cutoff ≥-70·1 HU) are an indicator of increased cardiac mortality and, therefore, could guide early targeted primary prevention and intensive secondary prevention in patients. FUNDING: British Heart Foundation, and the National Institute of Health Research Oxford Biomedical Research Centre.
Asunto(s)
Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Adipocitos , Tejido Adiposo/diagnóstico por imagen , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Enfermedad de la Arteria Coronaria/mortalidad , Vasos Coronarios/diagnóstico por imagen , Femenino , Estudios de Seguimiento , Humanos , Imagenología Tridimensional , Masculino , Persona de Mediana Edad , Placa Aterosclerótica/diagnóstico por imagen , Valor Predictivo de las Pruebas , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Medición de Riesgo , Análisis de Supervivencia , Adulto JovenRESUMEN
BACKGROUND: Optimal implantation results of bioresorbable scaffolds (BRS) are typically assumed to require postdilatation with non-compliant (NC) balloons to achieve full scaffold apposition and minimize event rates. We systematically evaluated the mechanical effect of NC balloon postdilatation on magnesium-based BRS (Magmaris®, Biotronik AG, Bülach, Switzerland) in vivo. METHODS: In 35 patients, 40 Magmaris® BRS were implanted to treat 37 de novo coronary artery stenoses. A systematic implantation protocol was followed. After appropriately sized NC balloon predilatation (1:1:1 vessel:balloon:scaffold ratio), Magmaris® BRS were implanted with a pressure of 10 atm, followed by NC balloon postdilatation at nominal BRS size (standardized at 16 atm). OCT was performed before and after postdilatation and OCT images were analyzed at a spacing of 0.2 mm to measure BRS dimensions and determine apposition as well as to detect strut fractures. RESULTS: PCI with Magmaris® BRS (mean diameter: 3.21 ± 0.32 mm; mean length: 20 ± 4 mm) was successful in all cases, in one case a non-flow-limiting distal edge dissection occurred after implantation and before postdilatation. NC balloon postdilatation led to significantly larger mean scaffold diameter (3.21 ± 0.32 mm vs. 2.80 ± 0.39 mm, P < 0.001), abluminal scaffold area (7.92 ± 1.43 mm2 vs. 6.72 ± 1.28 mm2 , P < 0.001) and lumen area (7.58 ± 1.1 mm2 vs. 6.83 ± 1.12 mm2 , P < 0.001). Incomplete scaffold apposition area was significantly lower if postdilatation was performed (0.01 ± 0.04 mm2 vs. 0.17 ± 0.11 mm2 , P < 0.001). Strut fractures could neither be observed before nor after postdilatation. CONCLUSION: NC balloon postdilatation of Magmaris® BRS is required to achieve optimal expansion. It significantly reduces malapposition and can safely be performed without relevant rates of strut fracture.
Asunto(s)
Implantes Absorbibles , Angioplastia Coronaria con Balón/instrumentación , Estenosis Coronaria/terapia , Magnesio , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Estenosis Coronaria/diagnóstico por imagen , Falla de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Estrés Mecánico , Factores de Tiempo , Tomografía de Coherencia Óptica , Resultado del TratamientoRESUMEN
BACKGROUND: The aim of this study was to analyze individual differences in resorption of bioresorbable vascular scaffolds (BRS) through optical coherence tomography (OCT) analysis and to identify factors potentially influencing the resorption process. METHODS: Between April 2016 and July 2017 clinically driven invasive coronary angiography and OCT examinations were performed in 36 patients who had previously been treated with a total of 48 BRS (ABSORB BVS, Abbott Vascular, Santa Clara, CA). For each scaffold, a new BRS-RESORB-INDEX (BRI) was calculated. RESULTS: The mean time interval since implantation was 789 ± 321 days. In OCT, BRS struts remained detectable in all 48 BRS. Normalized light intensity as a marker for the resorption of BRS struts increased with time in a linear fashion (Spearman Rho: p < .001, correlation coefficient = .90; R2 [linear] = .91). Multivariable analysis identified diabetes (BRI of patients with diabetes vs. patients without diabetes: 0.34 ± 0.13 vs. 0.58 ± 0.22; p = .002) and presence of Peri-strut low intensity areas (PSLIA, BRI of 10 patients with PSLIA vs. 26 patients without PSLIA: 0.44 ± 0.21 vs. 0.61 ± 18; p = .027) as independent predictors for a prolonged BRS resorption, whereas the resorption rate in ACS patients (STEMI, NSTEMI, and unstable angina; n = 13) was significantly higher as compared to patients without ACS (0.62 ± 0.17 vs. 0.43 ± 0.24; p = .012). CONCLUSION: In humans, BRS resorption rate is significantly influenced by numerous factors. Our data suggest that diabetes and PSLIA are associated with a prolonged resorption process, whereas in ACS patients, BRS resorption appears to be significantly faster.
Asunto(s)
Implantes Absorbibles , Síndrome Coronario Agudo/terapia , Enfermedad de la Arteria Coronaria/terapia , Vasos Coronarios/diagnóstico por imagen , Intervención Coronaria Percutánea/instrumentación , Poliésteres/química , Tomografía de Coherencia Óptica , Síndrome Coronario Agudo/diagnóstico por imagen , Anciano , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del TratamientoRESUMEN
BACKGROUND: The factors influencing genesis of atherosclerosis at specific regions within the coronary arterial system are currently uncertain. Local mechanical factors such as shear stress as well as metabolic factors, including inflammatory mediators released from epicardial fat, have been proposed. We analyzed computed tomographic (CT) attenuation of pericoronary adipose tissue in normal versus atherosclerotic coronary segments as defined by intravascular ultrasound (IVUS). PATIENTS AND METHODS: We evaluated the data sets of 29 patients who were referred for invasive coronary angiography and in whom IVUS of 1 coronary vessel was performed for clinical reasons. Coronary CT angiography was performed within 24 hours from invasive coronary angiography. Computed tomographic angiography was performed using dual-source CT (Siemens Healthcare; Forchheim, Germany). A contrast-enhanced volume data set was acquired (120 kV, 400 mA/rot, collimation 2 × 64 × 0.6 mm, 60-80 mL intravenous contrast agent). Intravascular ultrasound was performed using a 40-MHz IVUS catheter (Atlantis; Boston Scientific Corporation, Natick, Mass) and motorized pullback at 0.5 mm/s. Sixty corresponding coronary artery segments within the coronary artery system were identified in both dual source computed tomography and IVUS using bifurcation points as fiducial markers. In dual source computed tomography data sets, 8 serial parallel cross sections (2-mm slice thickness) were rendered orthogonal to the center line of the coronary artery for each segment. For each cross section, pericoronary adipose tissue within a radius of 3 mm from the coronary artery and enclosed within the epicardium (excluding coronary veins and myocardium) was manually traced and mean CT attenuation values were obtained. Intravascular ultrasound was used to define coronary segments as follows: presence of predominantly fibrous atherosclerotic plaque (hyperechoic), presence of predominantly lipid-rich atherosclerotic plaque (hypoechoic), and absence of atherosclerotic plaque. RESULTS: In IVUS, 20 coronary segments with fibrous plaque, 20 segments with lipid-rich plaque, and 20 coronary segments without plaque were identified. The mean CT attenuation of pericoronary adipose tissue for segments with any coronary atherosclerotic plaque was -34 ± 14 Hounsfield units (HU), as compared with -56 ± 16 HU for segments without plaque (P = 0.005). The density of pericoronary fat in segments with fibrous versus lipid-rich plaque as defined by IVUS was not significantly different (-35 ± 19 HU vs -36 ± 16 HU, P = 0.8). CONCLUSIONS: Mean CT attenuation of pericoronary adipose tissue is significantly lower for normal versus atherosclerotic coronary segments. This supports a hypothesis of different types of pericoronary adipose tissue, the more metabolically active of which might exert local effects on the coronary vessels, thus contributing to atherogenesis.
Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Aterosclerosis/diagnóstico por imagen , Angiografía por Tomografía Computarizada/métodos , Angiografía Coronaria/métodos , Ultrasonografía Intervencional/métodos , Anciano , Anciano de 80 o más Años , Medios de Contraste , Femenino , Humanos , Aumento de la Imagen , Masculino , Persona de Mediana EdadRESUMEN
OCT requires intracoronary injection of contrast agent to remove blood from the coronary lumen during data acquisition, which is a possible limitation of this method. Aim of this study was to analyze the influence of iodine concentration on image quality and diagnostic certainty of optical coherence tomography (OCT). OCT sequences acquired using contrast agent with a reduced concentration of 150 mg iodine/ml and a standard concentration of 350 mg iodine/ml were analyzed. Cross-sectional images with a spacing of 10 mm were evaluated regarding image quality and diagnostic confidence. A total of 67 OCT sequences acquired in 24 patients were analyzed. 31 sequences were acquired using contrast agent with a concentration of 150 mg iodine/ml and 36 sequences with a concentration of 350 mg iodine/ml. The percentage of remaining blood streaks in the cross sections was significantly lower for 350 mg iodine/ml compared to 150 mg iodine/ml (19 ± 21 vs. 34 ± 26%, p = 0.013). Contrast with 350 mg iodine/ml showed a significantly higher percentage of completely flushed pullback length as compared to 150 mg iodine/ml (78 ± 24 vs. 58 ± 27%, p = 0.004). Diagnostic certainty was significantly higher for 350 mg iodine/ml than for 150 mg iodine/ml (Likert scale average 1.4 ± 0.7 vs. 2.1 ± 1.2, p < 0.001; Likert scale: 1 = absolutely confident, 2 = confident with slight doubts, 3 = doubtful/not confident, 4 = non-diagnostic). Regarding image quality and diagnostic certainty, contrast agent with a concentration of 350 mg iodine/ml is superior to 150 mg iodine/ml.
Asunto(s)
Medios de Contraste/administración & dosificación , Interpretación de Imagen Asistida por Computador/normas , Yodo/administración & dosificación , Tomografía de Coherencia Óptica , Anciano , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estudios Transversales , Femenino , Alemania , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria PercutáneaRESUMEN
Objectives The purpose of this study was to determine applicability and procedural success of bioresorbable vascular scaffolds (BVS) for percutaneous coronary intervention (PCI) in an all-comer cohort. Background BVS use in bifurcations and severely calcified lesions is not recommended, and a relatively large crossing profile may cause limitations. It is has never been studied how widely BVS can be applied in all-comer cohorts. Methods In 383 consecutive patients (acute coronary syndrome: 124, stable coronary disease 259), a BVS (Absorb) was used as first-line device unless any of the following contraindications were present: bifurcation with side branch >2.0 mm, reference diameter <2.5 mm or >4.0 mm, required device length <12 mm, in-stent stenosis, or contraindications to 6 months of DAPT. Patients and lesions were evaluated regarding suitability for BVS treatment, procedural success (successful BVS placement and residual stenosis <30%), and outcome. Results Of 588 lesions, 303 (52%) were unsuitable for BVS placement due to presence of a bifurcation (30% of unsuitable lesions), reference -diameter >4.0 mm (13%) or <2.5 mm (12%), contraindication to 6 months DAPT (13%), in-stent stenosis (14%), and desired device length <12 mm (4%). If BVS use was attempted, procedural success with a scaffold was 95% (271/285). Crossing failure occurred in 14 cases (5%), affected lesions were significantly more calcified. After a mean follow-up period of 259 days, definite/probable scaffold thrombosis occurred in 1.1% of patients. Conclusions Approximately one-half of lesions in an all-comer population can successfully be treated with BVS. Crossing failure is rare.
Asunto(s)
Implantes Absorbibles , Síndrome Coronario Agudo/cirugía , Enfermedad de la Arteria Coronaria/cirugía , Intervención Coronaria Percutánea/instrumentación , Síndrome Coronario Agudo/diagnóstico por imagen , Anciano , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Trombosis Coronaria/etiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Diseño de Prótesis , Factores de Riesgo , Factores de Tiempo , Resultado del TratamientoRESUMEN
PURPOSE: To compare the diagnostic performance of 320-detector row computed tomography (CT) coronary angiography-derived computed fractional flow reserve (FFR; FFRCT), transluminal attenuation gradient (TAG; TAG320), and CT coronary angiography alone to diagnose hemodynamically significant stenosis as determined by invasive FFR. MATERIALS AND METHODS: This substudy of the prospective NXT study (no. NCT01757678) was approved by each participating institution's review board, and informed consent was obtained from all participants. Fifty-one consecutive patients who underwent 320-detector row CT coronary angiographic examination and invasive coronary angiography with FFR measurement were included. Independent core laboratories determined coronary artery disease severity by using CT coronary angiography, TAG320, FFRCT, and FFR. TAG320 is defined as the linear regression coefficient between luminal attenuation and axial distance from the coronary ostium. FFRCT was computed from CT coronary angiography data by using computational fluid dynamics technology. Diagnostic performance was evaluated and compared on a per-vessel basis by the area under the receiver operating characteristic (ROC) curve (AUC). RESULTS: Among 82 vessels, 24 lesions (29%) had ischemia by FFR (FFR ≤ 0.80). FFRCT exhibited a stronger correlation with invasive FFR compared with TAG320 (Spearman ρ, 0.78 vs 0.47, respectively). Overall per-vessel accuracy, sensitivity, specificity, and positive and negative predictive values for TAG320 (<15.37) were 78%, 58%, 86%, 64%, and 83%, respectively; and those of FFRCT were 83%, 92%, 79%, 65%, and 96%, respectively. ROC curve analysis showed a significantly larger AUC for FFRCT (0.93) compared with that for TAG320 (0.72; P = .003) and CT coronary angiography alone (0.68; P = .008). CONCLUSION: FFRCT computed from 320-detector row CT coronary angiography provides better diagnostic performance for the diagnosis of hemodynamically significant coronary stenoses compared with CT coronary angiography and TAG320.
Asunto(s)
Angiografía Coronaria/métodos , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/fisiopatología , Reserva del Flujo Fraccional Miocárdico/fisiología , Tomografía Computarizada Multidetector/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Velocidad del Flujo Sanguíneo/fisiología , Técnicas de Imagen Sincronizada Cardíacas , Medios de Contraste , Femenino , Humanos , Yohexol , Yopamidol/análogos & derivados , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sensibilidad y EspecificidadRESUMEN
OBJECTIVES: Chronic renal failure is common in patients referred for transcatheter aortic valve implantation (TAVI). CT angiography is recommended and provides crucial information prior to TAVI. We evaluated the feasibility of a reduced contrast volume protocol for pre-procedural CT imaging. METHODS: Forty consecutive patients were examined with prospectively ECG-triggered high-pitch spiral acquisition using a novel third-generation dual-source CT system; 38 ml contrast agent was used. Image quality was graded on a visual scale (1-4). Contrast attenuation was measured at the level of the aortic root and at the iliac bifurcation. RESULTS: Mean patient age was 82 ± 6 years (23 males; 58 %). Mean attenuation/average image quality was 285 ± 60 HU/1.5 at the aortic annulus compared to 289 ± 74 HU/1.8 at the iliac bifurcation (p = 0.77/p = 0.29). Mean estimated effective radiation dose was 2.9 ± 0.3 mSv. A repeat acquisition was necessary in one patient due to image quality. Out of the 35 patients who underwent TAVI, 31 (89 %) patients had no or mild aortic regurgitation. Thirty-two (91 %) patients were discharged successfully. CONCLUSION: Pre-procedural CTA with a total of 38 ml contrast volume is feasible and clinically useful, using third-generation dual-source CT, allowing comprehensive imaging for procedural success. KEY POINTS: ⢠Reduction of contrast agent volume is crucial in patients with chronic renal failure. ⢠Novel third-generation computed tomography helps to reduce contrast agent volume. ⢠Pre-procedural CT allows comprehensive imaging for procedural success before heart valve implantation. ⢠A low-contrast CT protocol is feasible for pre-procedural TAVI planning.
Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Medios de Contraste/administración & dosificación , Tomografía Computarizada por Rayos X/métodos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Angiografía por Tomografía Computarizada , Estudios de Factibilidad , Femenino , Humanos , Fallo Renal Crónico , Masculino , Cuidados Preoperatorios/métodos , Estudios ProspectivosRESUMEN
BACKGROUND: Cerebral white matter lesions (WMLs) are more common in individuals with late-onset or late-life depression. It has been proposed that carotid atherosclerosis may predispose to WMLs by inducing cerebral hypoperfusion. This hemodynamic effect of carotid atherosclerosis could be important for the formation of WMLs in depression. METHODS: The case-control study included 29 patients with late-onset major depressive disorder and 27 controls matched for sex, age, and tobacco use. WML volume, carotid intima-media thickness, and coronary plaque volume were assessed using magnetic resonance imaging, ultrasound scan, and coronary computed tomography (CT) angiography, respectively. RESULTS: The mean age for the total sample was 59.7 ± 4.7 years. There was no difference in carotid intima-media thickness between patients and controls (p = 0.164), whereas a higher WML volume in the patients was found (p = 0.051). In both patients and controls, WML volume was associated with carotid but not with coronary atherosclerosis. In adjusted multiple linear regression, a 0.1mm increase in averaged carotid intima-media thickness was associated with a 52% (95% CI: 8.4-112, p = 0.032) increase in WML volume. The association between carotid intima-media thickness and WML volume was, however, similar in patients and controls. CONCLUSIONS: In older persons aged between 50 and 70 years, WMLs do not seem to be a part of generalized atherosclerotic disease, but seem to be dependent on atherosclerosis in the carotid arteries. Carotid atherosclerosis, however, could not explain the higher WML load observed in the depressed patients, and thus, studies are needed to establish the mechanisms linking depression and WMLs.
Asunto(s)
Encéfalo/diagnóstico por imagen , Enfermedades de las Arterias Carótidas/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Trastorno Depresivo Mayor/diagnóstico por imagen , Leucoencefalopatías/diagnóstico por imagen , Sustancia Blanca/diagnóstico por imagen , Anciano , Enfermedades de las Arterias Carótidas/epidemiología , Grosor Intima-Media Carotídeo , Estudios de Casos y Controles , Angiografía por Tomografía Computarizada , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/epidemiología , Trastorno Depresivo Mayor/epidemiología , Femenino , Humanos , Enfermedades de Inicio Tardío , Leucoencefalopatías/epidemiología , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , UltrasonografíaRESUMEN
Catheter-based aortic valve implantation is increasingly being performed in high-risk patients with symptomatic aortic valve stenosis. For successful planning of the procedure, CT has been shown to provide crucial information concerning the aortic root as well as the peripheral access vessels. This article illustrates the increasing role of CT before transcatheter aortic valve implantation.
Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas , Tomografía Computarizada por Rayos X , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Imagenología Tridimensional , Cuidados Preoperatorios , Reemplazo de la Válvula Aórtica Transcatéter/métodosRESUMEN
BACKGROUND: Increased epicardial fat volume (EFV) has been shown to be associated with coronary atherosclerosis. While it is postulated to be an independent risk factor, a possible mechanism is local or systemic inflammation. We analyzed the relationship between coronary atherosclerosis, quantified by coronary calcium in CT, epicardial fat volume and systemic inflammation. METHODS: Using non-enhanced dual-source CT, we quantified epicardial fat volume (EFV) and coronary artery calcium (CAC) in 391 patients who underwent coronary computed tomography for suspected coronary artery disease. In addition to traditional risk factors, serum markers of systemic inflammation were measured (IL-1α, IL-2, IL-4, IL-6, IL-7, IL-8, IL-10,IL-12, IL-13, IL-15, IL-17, IFN-γ, TNF-α, hs-CRP, GM-CS, G-CSF, MCP-1, MIP-1, Eotaxin and IP-10). In 94 patients follow-up data were obtained after 1.9 ± 0.5 years. RESULTS: The 391 patients had a mean age of 60 ± 10 years, and 69 % were males. Mean EFV was 116 ± 50 mL. Median CAC was 12 (IQR 0; 152). CAC and EFV showed a significant correlation (ρ = 0.37; P < 0.001). EFV and CAC were significantly correlated with the traditional risk factors like age, male gender, diabetes, smoking and hypertension. With regard to biomarkers, CAC was significantly associated (negatively) to G-CSF and IL-13. EFV (median binned) was significantly associated (positively) with IP-10 (P = 0.002) and MCP-1 (ρ = 0.037). In follow-up, EFV showed a mean annualized progression of 6 mL (IQR 3; 9) (P < 0.001); CAC progressed by a mean of six Agatston Units (IQR 0; 30). The progression of CAC was significantly correlated with the extent of EFV (P < 0.001) while there was no significant correlation between progression of EFV or CAC with systemic inflammation markers. CONCLUSION: Epicardial fat volume and the baseline extent as well as progression of coronary atherosclerosis-measured by the calcium score-are significantly correlated. While both baseline EFV and CAC displayed significant correlations with systemic inflammation markers, biomarkers were not predictive of the progression of CAC or EFV.
Asunto(s)
Tejido Adiposo/patología , Calcinosis/patología , Enfermedad de la Arteria Coronaria/patología , Inflamación/patología , Pericardio/patología , Tejido Adiposo/metabolismo , Anciano , Envejecimiento/metabolismo , Biomarcadores/sangre , Calcinosis/metabolismo , Enfermedad de la Arteria Coronaria/metabolismo , Citocinas/sangre , Progresión de la Enfermedad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pericardio/metabolismo , Factores de RiesgoRESUMEN
OBJECTIVES: To evaluate a systematic approach for measurement of aortic annulus dimensions by cardiac computed tomography. METHODS: CT data sets of 64 patients were evaluated. An oblique cross-section aligned with the aortic root was created by systematically identifying the caudal insertion points of the three aortic cusps and sequentially aligning them in a double oblique plane. Aortic annulus dimensions, distances of coronary ostia and a suitable fluoroscopic projection angle were independently determined by two observers. RESULTS: Interobserver intraclass correlation coefficients (ICC) for aortic annulus diameters were excellent (ICC 0.89-0.93). Agreement for prosthesis size selection was excellent (ĸ = 0.86 for mean, ĸ = 0.84 for area-derived and ĸ = 0.91 for circumference-derived diameter). Mean distances of the left/right coronary ostium were 13.4 ± 2.4/14.4 ± 2.8 mm for observer 1 and 13.2 ± 2.7/13.5 ± 3.2 mm for observer 2 (p = 0.30 and p = 0.0001, respectively; ICC 0.76/0.77 for left/right coronary artery). A difference of less than 10° for fluoroscopic projection angle was achieved in 84.3% of patients. CONCLUSIONS: A systematic approach to generate a double oblique imaging plane exactly aligned with the aortic annulus demonstrates high interobserver and intraobserver agreements for derived measurements which are not influenced by aortic root calcification. KEY POINTS: ⢠Systematic approach to generate a double oblique imaging plane for TAVI evaluation. ⢠This method is straightforward and software independent. ⢠An approach with high reproducibility, not influenced by aortic root calcification.
Asunto(s)
Estenosis de la Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/diagnóstico por imagen , Calcinosis/diagnóstico por imagen , Imagenología Tridimensional , Tomografía Computarizada Multidetector/métodos , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Femenino , Implantación de Prótesis de Válvulas Cardíacas/métodos , Humanos , Masculino , Curva ROC , Reproducibilidad de los ResultadosRESUMEN
BACKGROUND: Depression is a stronger predictor for the onset of or death from clinical coronary artery disease than traditional cardiovascular risk factors. The association between depression and coronary artery disease has previously been investigated in non-contrast enhanced computed tomography studies with conflicting results. The aim of this study was to further elucidate the depression-coronary artery disease relation by use of coronary computed tomography angiography. METHODS: The calcified and noncalcified coronary plaque volumes were determined by semiautomatic volumetric quantification in 28 patients with late-onset major depression and 27 controls. The calcified plaque proportion, i.e., the calcified plaque volume divided by the total plaque volume, was used to assess the plaque composition. RESULTS: There was no statistically significant difference in the total (p = 0.48), calcified (p = 0.15), and noncalcified (p = 0.62) plaque volume between patients and controls, and the total plaque volume did not predict depression, odds ratio = 1.001 [95% confidence interval: 0.999-1.003; p = 0.23]. However, the calcified plaque proportion was twice as high in patients compared with controls (14% vs. 7%, p = 0.044). Correspondingly, having depression was associated with an increased calcified plaque proportion of 11.3 [95% confidence interval: 2.63-20.1; p = 0.012] percentage points after adjustment for demographics and cardiovascular risk factors. CONCLUSION: The proportion of the total coronary plaque volume that was calcified was significantly higher in patients with late-onset major depression than in controls, indicating a difference in plaque composition.
Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Trastorno Depresivo Mayor/epidemiología , Placa Aterosclerótica/diagnóstico por imagen , Calcificación Vascular/diagnóstico por imagen , Edad de Inicio , Anciano , Estudios de Casos y Controles , Comorbilidad , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/epidemiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Placa Aterosclerótica/epidemiología , Tomografía Computarizada por Rayos X , Calcificación Vascular/epidemiologíaRESUMEN
INTRODUCTION: Recent studies have shown a significant correlation between increased epicardial fat volume (EFV) and mortality, coronary artery disease events, and measures of coronary atherosclerotic burden, for example, coronary calcium. Patients with chronic kidney disease on hemodialysis have an increased prevalence of coronary atherosclerosis and coronary calcium. The mechanisms underlying both may differ from patients with normal kidney function. Only limited data are available on the relationship between epicardial fat and coronary calcium in these patients. METHODS: Ninety-three consecutive patients (62 men and 31 women; mean age, 55 ± 11 years) with chronic kidney failure on regular hemodialysis underwent computed tomography for coronary calcium scoring as well as assessment of cardiovascular risk factors. Calcium scoring was performed using a low-dose, prospectively ECG-triggered high pitch spiral acquisition protocol (dual-source computed tomography, 280-millisecond (ms) rotation, 2 × 128 × 0.6-mm collimation, 120-kV tube voltage, 80-mA·s tube current). Cross-sectional images were reconstructed with 3.0-mm thickness, 1.5-mm increment, and a medium sharp reconstruction kernel (B35f). Agatston score and EVF were analyzed in a semiautomatic fashion using dedicated software. RESULTS: The mean duration of dialysis was 5.7 years. Of all patients, 93% had arterial hypertension, 66% had hyperlipidemia, 30% were diabetic, and 49.5% were current or prior smokers. The mean body mass index (BMI) was 27 ± 4 kg/m. The mean EFV was 162 ± 80 mL, and the mean coronary artery calcification (CAC) was 765 ± 1391 Agatston units (AU). In univariable and multivariable analysis, EFV was significantly correlated to BMI (P < 0.05) and age (P = 0.021), but not to CAC (P = 0.106). In subanalysis for values binned by median, we also found a significant correlation between EFV (binned) and smoking (P = 0.49) as well as a significant correlation between EFV (binned) and CAC for 46 patients younger than 55 years (median age). CONCLUSION: The epicardial fat volume in patients with chronic kidney disease and on hemodialysis is significantly correlated to BMI, age, and smoking but, with the exception of younger patients, not to the coronary calcium score. Our data suggest that in this special patient cohort, other mechanisms might influence the genesis of coronary calcification.
Asunto(s)
Adiposidad , Calcinosis/epidemiología , Enfermedad de la Arteria Coronaria/epidemiología , Pericardio/diagnóstico por imagen , Diálisis Renal/estadística & datos numéricos , Insuficiencia Renal Crónica/epidemiología , Insuficiencia Renal Crónica/terapia , Tejido Adiposo/diagnóstico por imagen , Adulto , Anciano , Calcinosis/diagnóstico por imagen , Causalidad , Angiografía Coronaria/estadística & datos numéricos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Femenino , Alemania/epidemiología , Humanos , Incidencia , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Prevalencia , Reproducibilidad de los Resultados , Factores de Riesgo , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/estadística & datos numéricosRESUMEN
AIMS: Transcatheter aortic valve implantation (TAVI) has become a minimally invasive alternative to surgical aortic valve replacement. Hypo-attenuated leaflet thickening (HALT)-a marker of subclinical leaflet thrombosis commonly detected by cardiac computed tomography (CT) after TAVI-may influence valve durability and function. The purpose of this study was to compare commissural alignment of the native and prosthetic aortic valves in cardiac CT in subjects with and without HALT and thereby identify commissural misalignment as potential predictor for leaflet thrombosis after TAVI. METHODS AND RESULTS: In 170 subjects, 85 with and 85 without HALT in post-TAVI CT, commissural orientation of the prosthesis was determined comparing native and prosthetic aortic valve orientation in cardiac CT by measuring the commissural angle relative to the right coronary ostium in the aortic valve plane. For the prosthetic valve, any deviation ≤ 15° compared to the native valve was classified as "aligned"; 16-30° as "mild", 31-45° as "moderate" and ≥ 45° as "severe" misalignment. Among subjects with HALT, median angular deviation was higher (36°, IQR 31°) than in the control group (29°, IQR 29°, p = 0.042). "Severe" misalignment was more frequent in subjects who developed HALT (n = 31, 37%) compared to the control group (n = 17, 20%, p = 0.013). In logistic regression analysis, more severe deviation (p = 0.015, OR = 1.02 per 1° deviation) and "severe" misalignment (p = 0.018, OR = 2.2) represented independent predictors for the occurrence of HALT after TAVI. CONCLUSION: Subclinical leaflet thrombosis after TAVI is associated with commissural misalignment. Potential clinical advantages of obtaining commissural alignment remain to be systematically assessed.