Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Orthod Craniofac Res ; 2024 May 23.
Artículo en Inglés | MEDLINE | ID: mdl-38783751

RESUMEN

OBJECTIVES: This study aimed to establish a fully digital measurement protocol for standardizing the description of hard palate and cleft morphology in neonates with an isolated cleft palate (CPO) and Pierre Robin sequence (PRS). MATERIALS AND METHODS: A total of 20 digitized plaster models of neonates with CPO and 20 digitized plaster models of neonates with PRS were retrospectively investigated. For the control group, the hard palate was segmented from 21 pre-existing 1.5 T MRI datasets of neonates and exported as an STL file. The digital models were marked with predefined reference points by three raters. Distance, angular, and area measurements were performed using Blender and MeshLab. RESULTS: Neonates with CPO (20.20 ± 2.33 mm) and PRS (21.41 ± 1.81 mm) had a significantly shorter hard palate than the control group (23.44 ± 2.24 mm) (CPO vs. control: P < .001; PRS vs. control: P = .014). Notably, neonates with PRS (33.05 ± 1.95 mm) demonstrated a significantly wider intertuberosity distance than those with CPO (30.52 ± 2.28 mm) (P = .012). Furthermore, there were also significant differences measured between the cleft and control groups (25.22 ± 2.50 mm) (P < .001). CONCLUSIONS: The data from this study demonstrate the feasibility of using MRI datasets to generate digital models of the hard palate. The presence of a cleft palate leads to pronounced adaptations of the total palatal surface area, dorsal width, and length of the hard palate. Mandibular retrognathia and altered tongue position in PRS, as opposed to CPO, might further impact palatal morphology and intertuberosity distance.

2.
Radiol Med ; 129(2): 268-279, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38017228

RESUMEN

OBJECTIVES: To compare a novel, non-contrast, flow-independent, 3D isotropic magnetic resonance angiography (MRA) sequence that combines respiration compensation, electrocardiogram (ECG)-triggering, undersampling, and Dixon water-fat separation with an ECG-triggered aortic high-pitch computed tomography angiography (CTA) of the aorta. MATERIALS AND METHODS: Twenty-five patients with recent CTA were scheduled for non-contrast MRA on a 3 T MRI. Aortic diameters and cross-sectional areas were measured on MRA and CTA using semiautomatic measurement tools at 11 aortic levels. Image quality was assessed independently by two radiologists on predefined aortic levels, including myocardium, proximal aortic branches, pulmonary veins and arteries, and the inferior (IVC) and superior vena cava (SVC). Image quality was assessed on a 5-point Likert scale. RESULTS: All datasets showed diagnostic image quality. Visual grading was similar for MRA and CTA regarding overall image quality (0.71), systemic arterial image quality (p = 0.07-0.91) and pulmonary artery image quality (p = 0.05). Both readers favored MRA for SVC and IVC, while CTA was preferred for pulmonary veins (all p < 0.05). No significant difference was observed in aortic diameters or cross-sectional areas between native MRA and contrast-enhanced CTA (p = 0.08-0.94). CONCLUSION: The proposed non-contrast MRA enables robust imaging of the aorta, its proximal branches and the pulmonary arteries and great veins with image quality and aortic diameters and cross-sectional areas comparable to that of CTA. Moreover, this technique represents a suitable free-breathing alternative, without the use of contrast agents or ionizing radiation. Therefore, it is especially suitable for patients requiring repetitive imaging.


Asunto(s)
Angiografía por Tomografía Computarizada , Medios de Contraste , Humanos , Angiografía por Resonancia Magnética/métodos , Vena Cava Superior/diagnóstico por imagen , Arteria Pulmonar
3.
Odontology ; 2024 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-38758257

RESUMEN

The maxilla occupies a key position in dentofacial orthopaedics, since its transversal development can be directly influenced by orthodontic therapy. The maturation stages of the mid-palatal suture, which are obtained from cone-beam computed tomography images (CBCT), present an addition to clinical decision-making in transversal discrepancies of the upper jaw. In an endeavour to reduce ionizing radiation in adolescents and young adults, who are particularly susceptible to long term stochastic irradiation effects, we investigated the feasibility of 3 Tesla (3T) MRI in detecting the maturation stages of the mid-palatal suture. A collective of 30 patients aged 24-93 years with routine neck MRI at 3T, underwent an additional three-dimensional isotropic T1 weighted study sequence of the midface. Image evaluation was performed on axial, multi-planar formatted reconstructions of the dataset aligned to the midline axis of the palate, and curved reconstructions aligned to the concavity of the palate. Inverted images helped to achieve an image impression similar to the well-known CBCT appearance. All datasets were reviewed by three readers and mid-palatal maturation was scored twice according to Angelieri et al. Intra- and inter-rater agreement were evaluated to measure the robustness of the images for clinical evaluation. 3T MRI deemed reliable for the assessment of mid-palatal suture maturation and hence for the appraisal of the hard palate and its adjacent sutures. The data of this pilot study display the feasibility of non-ionizing cross-sectional MRI for the determination of sutural maturation stages. These findings underline the potential of MRI for orthodontic treatment planning, further contributing to the avoidance of unnecessary radiation doses.

4.
Clin Oral Investig ; 28(1): 55, 2023 Dec 29.
Artículo en Inglés | MEDLINE | ID: mdl-38157063

RESUMEN

OBJECTIVES: Skull morphology and growth patterns are essential for orthodontic treatment, impacting clinical decision making. We aimed to determine the association of different cephalometric skeletal configurations on midface parameters as measured in 3D CT datasets. MATERIALS AND METHODS: After sample size calculation, a total of 240 fully dentulous patients between 20 and 79 years of age (mean age: 42 ± 15), who had received a CT of the skull within the scope of trauma diagnosis or intracranial bleeding, were retrospectively selected. On the basis of cephalometric analysis, using MPR reconstructions, patients were subdivided into three different vertical skull configurations (brachyfacial, mesofacial, dolichofacial) and the respective skeletal Class I, II, and III relationships. Anatomic parameters were measured using a three-dimensional post-processing console: the thickness of the maxillary and palatine bones as well as the alveolar crest, maxillary body and sutural length, width and height of the hard palate, maxillary facial wall thickness, and masseter muscle thickness and length. RESULTS: Individuals with brachyfacial configurations had a significantly increased palatal and alveolar ridge thicknesses compared to those with dolichofacial- or mesofacial configurations. Brachyfacial configurations presented a significantly increased length and thickness of the masseter muscle (4.599 cm; 1.526 cm) than mesofacial (4.431 cm; 1.466 cm) and dolichofacial configurations (4.405 cm; 1.397 cm) (p < 0.001). Individuals with a skeletal Class III had a significantly shorter palatal length (5.313 cm) than those with Class I (5.406 cm) and Class II (5.404 cm) (p < 0.01). Sutural length was also significantly shorter in Class III (p < 0.05). CONCLUSIONS: Skeletal configurations have an impact on parameters of the bony skull. Also, measurable adaptations of the muscular phenotype could result. CLINICAL RELEVANCE: The association between viscerocranial morphology and midface anatomy might be beneficial for tailoring orthodontic appliances to individual anatomy and planning cortically anchored orthodontic appliances.


Asunto(s)
Cara , Maxilar , Adulto , Humanos , Persona de Mediana Edad , Estudios Retrospectivos , Cara/anatomía & histología , Cefalometría/métodos , Maxilar/diagnóstico por imagen , Maxilar/anatomía & histología , Paladar Duro
5.
Eur Radiol ; 32(11): 7700-7709, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35441839

RESUMEN

OBJECTIVES: The aim of this study was to compare the quality of images obtained using single-energy computed tomography (SECT) performed with automated tube voltage adaptation (TVA) with dual-energy CT (DECT) weighted average images. METHODS: Eighty patients were prospectively randomized to undergo either SECT with TVA (n = 40, ref. mAs 200) or radiation dose-matched DECT (n = 40, 80/Sn150 kV, ref. mAs tube A 91/tube B 61) on a dual-source CT scanner. Objective image quality was evaluated as dose-normalized contrast-to-noise ratio (CNRD) for the jugular veins relative to fatty tissue and muscle tissue and for muscle tissue relative to fatty issue. For subjective image quality, reproduction of anatomical structures, image artifacts, image noise, spatial resolution, and overall diagnostic acceptability were evaluated at sixteen anatomical substructures using Likert-type scales. RESULTS: Effective radiation dose (ED) was comparable between SECT and DECT study groups (2.9 ± 0.6 mSv/3.1 ± 0.7 mSv, p = 0.5). All examinations were rated as excellent or good for clinical diagnosis. Compared to the CNRD in the SECT group, the CNRD in the DECT group was significantly higher for the jugular veins relative to fatty tissue (7.51/6.08, p < 0.001) and for muscle tissue relative to fatty tissue (4.18/2.90, p < 0.001). The CNRD for the jugular veins relative to muscle tissue (3.33/3.18, p = 0.51) was comparable between groups. Image artifacts were less pronounced and overall diagnostic acceptability was higher in the DECT group (all p = 0.01). CONCLUSIONS: DECT weighted average images deliver higher objective and subjective image quality than SECT performed with TVA in head and neck imaging. KEY POINTS: • Weighted average images derived from dual-energy CT deliver higher objective and subjective image quality than single-energy CT using automated tube voltage adaptation in head and neck imaging. • If available, dual-energy CT acquisition may be preferred over automated low tube voltage adopted single-energy CT for both malignant and non-malignant conditions.


Asunto(s)
Cabeza , Tomografía Computarizada por Rayos X , Humanos , Dosis de Radiación , Estudios Prospectivos , Tomografía Computarizada por Rayos X/métodos , Cabeza/diagnóstico por imagen , Cuello
6.
Eur Radiol ; 31(4): 2263-2271, 2021 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-32970184

RESUMEN

OBJECTIVES: Conventional perfusion-weighted MRI sequences often provide poor spatial or temporal resolution. We aimed to overcome this problem in head and neck protocols using a golden-angle radial sparse parallel (GRASP) sequence. METHODS: We prospectively included 58 patients for examination on a 3.0-T MRI using a study protocol. GRASP (A) was applied to a volumetric interpolated breath-hold examination (VIBE) with 135 reconstructed pictures and high temporal (2.5 s) and spatial resolution (0.94 × 0.94 × 3.00 mm). Additional sequences of matching temporal resolution (B: 2.5 s, 1.88 × 1.88 × 3.00 mm), with a compromise between temporal and spatial resolution (C: 7.0 s, 1.30 × 1.30 × 3.00 mm) and with matching spatial resolution (D: 145 s, 0.94 × 0.94 × 3.00 mm), were subsequently without GRASP. Instant inline-image reconstructions (E) provided one additional series of averaged contrast information throughout the entire acquisition duration of A. Overall diagnostic image quality, edge sharpness and contrast of soft tissues, vessels and lesions were subjectively rated using 5-point Likert scales. Objective image quality was measured as contrast-to-noise ratio in D and E. RESULTS: Overall, the anatomic and pathologic image quality was substantially better with the GRASP sequence for the temporally (A/B/C, all p < 0.001) and spatially resolved comparisons (D/E, all p < 0.002 except lesion edge sharpness with p = 0.291). Image artefacts were also less likely to occur with GRASP. Differences in motion, aliasing and truncation were mainly significant, but pulsation and fat suppression were comparable. In addition, the contrast-to-noise ratio of E was significantly better than that of D (pD-E < 0.001). CONCLUSIONS: High temporal and spatial resolution can be obtained synchronously using a GRASP-VIBE technique for perfusion evaluation in head and neck MRI. KEY POINTS: • Golden-angle radial sparse parallel (GRASP) sampling allows for temporally resolved dynamic acquisitions with a very high image quality. • Very low-contrast structures in the head and neck region can benefit from using the GRASP sequence. • Inline-image reconstruction of dynamic and static series from one single acquisition can replace the conventional combination of two acquisitions, thereby saving examination time.


Asunto(s)
Aumento de la Imagen , Interpretación de Imagen Asistida por Computador , Artefactos , Medios de Contraste , Humanos , Imagenología Tridimensional , Imagen por Resonancia Magnética , Perfusión
7.
Medicina (Kaunas) ; 57(8)2021 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-34440984

RESUMEN

Background and Objectives: A rare case of cor triatriatum sinistrum in combination with anomalies in the atrial septum and in the right atrium of a 60-year-old female body donor is described here. Materials and Methods: In addition to classical dissection, ultrasound and magnetic resonance imaging, computer tomography and cinematic rendering were performed. In a reference series of 59 regularly formed hearts (33 men, 26 women), we looked for features in the left and right atrium or atrial septum. In addition, we measured the atrial and ventricular wall thickness in 15 regularly formed hearts (7 men, 8 women). Results: In the case described, the left atrium was partly divided into two chambers by an intra-atrial membrane penetrated by two small openings. The 2.5 cm-high membrane originated in the upper level of the oval fossa and left an opening of about 4 cm in diameter. Apparently, the membrane did not lead to a functionally significant flow obstruction due to the broad intra-atrial communication between the proximal and distal chamber of the left atrium. In concordance with this fact, left atrial wall thickness was not elevated in the cor triatriatum sinistrum when compared with 15 regularly formed hearts. In addition, two further anomalies were found: 1. the oval fossa was deepened and arched in the direction of the left atrium; 2. the right atrium showed a membrane-like structure at its posterior and lateral walls, which began at the lower edge of the oval fossa. It probably corresponds to a strongly developed eustachian valve (valve of the inferior vena cava). Conclusions: The case described suggests that malformations in the development of the atrial septum and in the regression of the valve of the right sinus vein are involved in the pathogenesis of cor triatriatum sinistrum.


Asunto(s)
Tabique Interatrial , Corazón Triatrial , Tabique Interatrial/diagnóstico por imagen , Corazón Triatrial/diagnóstico por imagen , Femenino , Atrios Cardíacos/diagnóstico por imagen , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Vena Cava Inferior
8.
J Cardiovasc Magn Reson ; 22(1): 39, 2020 05 28.
Artículo en Inglés | MEDLINE | ID: mdl-32460852

RESUMEN

BACKGROUND AND PURPOSE: Interpretation of T2 values remains difficult due to limited comparability across hardware and software systems and the lack of validated measurement recommendations for the number and orientation of mandatory slices. Our aims were to provide a standardized comparison of intra- and inter-individual T2 values in the short and long axes and to investigate inter-scanner reproducibility. METHOD AND MATERIALS: Ninety cardiovascular magnetic resonance (CMR) studies in 30 healthy subjects were performed with three identical 1.5 T CMR scanners (same hardware and software) using a balanced steady-state free precession (bSSFP) gradient echo sequence in three short axis (SAx) and three long axis (LAx) views. A commercially available T2 mapping software package of the latest generation with automatic in-line motion correction was used for acquisition. Regions of interest were manually drawn in each of the 16 myocardial segments according to the American Heart Association (AHA) model in three SAx and three LAx acquisitions. Analysis of inter-scanner, inter-segmental, intra-segmental, inter-regional and inter-level differences was performed. RESULTS: Inter-scanner reproducibility was high and the mean myocardial T2 value for all evaluated segments was 45.7 ± 3.4 ms. Significant inter-segmental variations of mean T2 values were found. Mean intra-segmental T2 values were comparable between LAx and SAx acquisitions in 72%. Significantly higher T2 values were found in apical segments and a significant disparity among different regions was found for SAx and LAx orientations. CONCLUSION: Standardized cardiac T2 mapping is highly reproducible on identical CMR systems. T2 values vary significantly between single heart segments, regions, levels, and axes in young, healthy subjects.


Asunto(s)
Corazón/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Cinemagnética/instrumentación , Programas Informáticos , Adulto , Femenino , Voluntarios Sanos , Humanos , Masculino , Variaciones Dependientes del Observador , Valor Predictivo de las Pruebas , Estudios Prospectivos , Reproducibilidad de los Resultados , Adulto Joven
10.
Eur Radiol ; 29(8): 4207-4214, 2019 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-30338365

RESUMEN

OBJECTIVES: The aim of this study was to compare image quality of single-source dual-energy CT (SS-DECT) with third-generation dual-source dual-energy CT (DS-DECT) in head and neck cancer. MATERIALS AND METHODS: One hundred two patients with histologically proven head and neck cancer were prospectively randomized to undergo radiation dose-matched SS-DECT (n = 51, 120 kV, split-filter technique, 384 ref. mAs) or DS-DECT (n = 51, 80/Sn150 kV, tube A 100/tube B 67 ref. mAs). Inline default images (DI) and virtual monoenergetic images (VMI) for two different low energies (40 and 60 keV) were reconstructed. Objective image quality was evaluated as dose-normalized contrast to noise ratio (CNRD), and subjective image quality was rated on a 5-point Likert scale. RESULTS: In both groups, highest CNRD values for vessel and tumor attenuation were obtained at 40 keV. DS-DECT was significantly better than SS-DECT regarding vessel and tumor attenuation. Overall subjective image quality in the SS-DECT group was highest on the DI followed by 40 keV and 60 keV. In the DS-DECT group, subjective image quality was highest at 40 keV followed by 60 keV and the DI. Forty kiloelectron volts and 60 keV were significantly better in the DS-DECT compared to the SS-DECT group (both p < 0.01). CONCLUSIONS: In split-filter SS-DECT as well as in DS-DECT, highest overall image quality in head and neck imaging can be obtained with a combination of DI and low keV reconstructions. DS-DECT is superior to split-filter SS-DECT in terms of subjective image quality and vessel and tumor attenuation. KEY POINTS: • Image quality was diagnostic with both dual-energy techniques; however, the dual-source technique delivered significantly better results. • Highest overall image quality in head and neck imaging can be obtained with a combination of default images and low keV reconstructions with both dual-energy techniques. • The results of this study may have relevance for the decision-making process regarding replacement of CT scanners and focused patient examination considering image quality and subsequent therapeutic decision-making.


Asunto(s)
Neoplasias de Cabeza y Cuello/diagnóstico por imagen , Tomografía Computarizada por Rayos X/normas , Femenino , Cabeza/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Persona de Mediana Edad , Cuello/diagnóstico por imagen , Exposición a la Radiación , Imagen Radiográfica por Emisión de Doble Fotón/métodos , Imagen Radiográfica por Emisión de Doble Fotón/normas , Tomografía Computarizada por Rayos X/métodos
11.
Eur Radiol ; 29(7): 3686-3695, 2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-31041566

RESUMEN

OBJECTIVES: To assess the incidence of acute adverse events (AAEs) in gadolinium-enhanced cardiac magnetic resonance (CMR) imaging. METHODS: Gadolinium-based contrast agent (GBCA)-enhanced CMR data from the multinational, multicenter European Society of Cardiovascular Radiology MRCT Registry was included. AAE severity was classified according to the American College of Radiology Manual on Contrast Media (mild, moderate, severe). Multivariable generalized linear mixed effect models were used to assess the likelihood of AAEs in various GBCA, adjusting for pharmacological stressor, main indications (i.e., suspected or known coronary artery disease or myocarditis), age, sex, and submitting center as a random effect. RESULTS: In the study population of 72,839 GBCA-enhanced CMRs, a total of 260 AAEs were reported (0.36%), with a minority of severe AAEs (n = 24, 0.033%). Allergic-like AAEs were less likely than physiologic AAEs (29% versus 71%). Patients without pharmacological stress imaging had a lower AAE rate (0.22%) compared to stress imaging (0.75%), with the highest AAE rates for regadenoson (2.95%). AAE rates also varied by GBCA subtype (overall p < 0.001). There was significant interaction between GBCA and pharmacological stressor (interaction p = 0.025), with AAE rates ranging between 0 and 10% for certain GBCA/stressor combinations. There was further marginal evidence that higher GBCA volume was associated with higher AAE incidence (OR = 1.02, p = 0.05). CONCLUSION: GBCA-enhanced CMR imaging demonstrates low AAE rates comparable to those of other body regions. AAE likelihood correlates with GBCA subtype, pharmacological stressor, and imaging indication. Intravenous fluid administration in patients with cardiac impairment might contribute to these findings. KEY POINTS: • Acute adverse event rates in cardiac magnetic resonance (CMR) imaging with gadolinium-based contrast agents (GBCAs) are low (0.36%), especially for severe adverse events (0.033%). • Mild and moderate adverse events are more frequent during stress CMR imaging. • Physiologic AAEs are more common than allergic AAEs in CMR imaging.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos/etiología , Imagen por Resonancia Cinemagnética/efectos adversos , Compuestos Organometálicos/efectos adversos , Radiología , Sistema de Registros , Sociedades Médicas , Enfermedad Aguda , Administración Intravenosa , Efectos Colaterales y Reacciones Adversas Relacionados con Medicamentos/epidemiología , Europa (Continente)/epidemiología , Femenino , Humanos , Incidencia , Imagen por Resonancia Cinemagnética/métodos , Masculino , Persona de Mediana Edad , Compuestos Organometálicos/administración & dosificación , Estudios Retrospectivos
12.
J Med Syst ; 43(1): 14, 2018 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-30535865

RESUMEN

A CT system with a tablet as mobile user interface and a wireless remote control for positioning and radiation release has recently been presented. Our aim was to evaluate the effects of a mobile CT examination workflow on the radiographers' performance compared to conventional examinations. A prototype of a radiation protection cabin was installed besides the gantry of a CT system. The CT system was equipped with a simplified user interface on a portable tablet and a mobile remote control. 98 patients with an indication for CT of the chest were randomly assigned to examination using the mobile devices (study group, n = 47) or using the conventional stationary workflow on the console (reference group, n = 51). Three ceiling mounted fisheye cameras were used for motion tracking of the radiographers, two in the examination room and one in the control room. Relative density of detection heat-maps and area counts were assessed using a dedicated software tool to quantify radiographers' movements. Duration of each task of the examination was manually recorded using a stopwatch. In the reference group 25% of the area counts were located inside of the examination room, while it was 48% in the study group. The time spent in the same room with the patient increased from 3:06 min (29%) to 6:01 min (57%) using the mobile workflow (p < 0.05), thereof 0:59 min (9%) were spent in moderate separation with maintained voice and visual contact in the radiation protection cabin. Heat-maps showed an increase of the radiographer's working area, indicating a higher freedom of movement. Total duration of the examination was slightly less in the study group without statistical significance (median time: study 10:36, reference 10:50 min; p = 0.29). A mobile CT examination transfers the radiographers' interaction with the scanner from the control room into the examination room. There, radiographers' freedom of movement is higher, without any tradeoffs regarding the examination duration.


Asunto(s)
Computadoras de Mano , Tórax/diagnóstico por imagen , Tomografía Computarizada por Rayos X/instrumentación , Flujo de Trabajo , Humanos , Movimiento , Sistemas de Atención de Punto , Protección Radiológica/métodos , Análisis y Desempeño de Tareas , Factores de Tiempo , Interfaz Usuario-Computador
13.
Diagnostics (Basel) ; 13(14)2023 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-37510147

RESUMEN

(1) Purpose: to compare right ventricular (RV) functional parameters in children with surgically repaired congenital heart disease (CHD) using single/double breath hold (BH) and free-breathing (FB) real-time compressed sensing (CS) cine cardiac magnetic resonance (cMRI) with standard retrospective segmented multi breath hold (RMB) cine cMRI. (2) Methods: Twenty patients with CHD underwent BH and FB, as well as RMB cine cMRI, at 3T to obtain a stack of continuous axial images of the RV. Two radiologists independently performed qualitative analysis of the image quality (rated on a 5-point scale; 1 = non-diagnostic to 5 = excellent) and quantitative analysis of the RV volume measurements. (3) Results: The best image quality was provided by RMB (4.5; range 2-5) compared to BH (3.9; range 3-5; p = 0.04) and FB (3.6; range 3-5; p < 0.01). The RV functional parameters were comparable among BH, FB, and RMB with a difference of less than 5%. The scan times for BH (44 ± 38 s, p < 0.01) and FB (24 ± 7 s, p < 0.01) were significantly reduced compared to for RMB (261 ± 68 s). (4) Conclusions: CS-FB and CS-BH real-time cine cMRI in children with CHD provides diagnostic image quality with excellent accuracy for measuring RV function with a significantly reduced scan time compared to RMB.

14.
Acad Radiol ; 30(12): 2962-2972, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37179206

RESUMEN

RATIONALE AND OBJECTIVES: The purpose of this study was to evaluate the diagnostic utility of iterative metal artifact reduction (iMAR) in computed tomography (CT)-imaging of oral and oropharyngeal cancers when obscured by dental hardware artifacts and to determine the most appropriate iMAR settings for this purpose. MATERIALS AND METHODS: The study retrospectively enrolled 27 patients (8 female, 19 male; mean age 64±12.7years) with histologically confirmed oral or oropharyngeal cancer obscured by dental artifacts in contrast-enhanced CT. Raw CT data were reconstructed with ascending iMAR strengths (levels 1/2/3/4/5) and one reconstruction without iMAR (level 0). For subjective analysis, two blinded radiologists rated tumor visualization and artifact severity on a five-point Likert scale. For objective analysis, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and artifact index (AI) were determined. RESULTS: iMAR reconstructions improved the subjective image quality of tumor edge and contrast, and the objective parameters of tumor SNR and CNR, reaching their optimum at iMAR levels 4 and 5 (P<.001). AI decreased with iMAR reconstructions reaching its minimum at iMAR level 5 (P<.001). Tumor detection rates increased 2.4-fold with iMAR 5, 2.1-fold with iMAR 4, and 1.9-fold with iMAR 3 compared to reconstructions without iMAR. Disadvantages such as algorithm-induced artifacts increased significantly with higher iMAR strengths (P<.05), reaching a maximum with iMAR 5. CONCLUSION: iMAR significantly improves CT imaging of oral and oropharyngeal cancers, as confirmed by both subjective and objective measures, with best results at highest iMAR strengths.


Asunto(s)
Artefactos , Neoplasias Orofaríngeas , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Estudios Retrospectivos , Metales , Tomografía Computarizada por Rayos X/métodos , Neoplasias Orofaríngeas/diagnóstico por imagen , Algoritmos
15.
Diagnostics (Basel) ; 13(7)2023 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-37046460

RESUMEN

This study compares the diagnostic performance and image quality of single-shot turbo spin-echo DWI (tseDWI), standard readout-segmented DWI (rsDWI), and a modified rsDWI version (topupDWI) for cholesteatoma diagnostics. Thirty-four patients with newly suspected unilateral cholesteatoma were examined on a 1.5 Tesla MRI scanner. Diagnostic performance was evaluated by calculating and comparing the sensitivity and specificity using histopathological results as the standard of reference. Image quality was independently reviewed by two readers using a 5-point Likert scale evaluating image distortions, susceptibility artifacts, image resolution, lesion conspicuity, and diagnostic confidence. Twenty-five cholesteatomas were histologically confirmed after surgery and originated in the study group. TseDWI showed the highest sensitivity with 96% (95% confidence interval (CI): 88-100%), followed by topupDWI with 92% (95% CI: 81-100%) for both readers. The sensitivity for rsDWI was 76% (95% CI: 59-93%) for reader 1 and 84% (95% CI: 70-98%) for reader 2, respectively. Both tseDWI and topupDWI revealed a specificity of 100% (95% CI: 66-100%) and rsDWI of 89% (95% CI: 52-100%). Both tseDWI and topupDWI showed fewer image distortions and susceptibility artifacts compared to rsDWI. Image resolution was consistently rated best for topupDWI, followed by rsDWI, which both outperformed tseDWI. TopupDWI and tseDWI showed comparable results for lesions' conspicuity and diagnostic confidence, both outperforming rsDWI. Modified readout-segmented DWI using the topup-correction method is preferable to standard rsDWI and may be regarded as an accurate alternative to single-shot turbo spin-echo DWI in cholesteatoma diagnostics.

16.
Bioengineering (Basel) ; 10(12)2023 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-38135956

RESUMEN

Intracranial hemorrhages require an immediate diagnosis to optimize patient management and outcomes, and CT is the modality of choice in the emergency setting. We aimed to evaluate the performance of the first scanner-integrated artificial intelligence algorithm to detect brain hemorrhages in a routine clinical setting. This retrospective study includes 435 consecutive non-contrast head CT scans. Automatic brain hemorrhage detection was calculated as a separate reconstruction job in all cases. The radiological report (RR) was always conducted by a radiology resident and finalized by a senior radiologist. Additionally, a team of two radiologists reviewed the datasets retrospectively, taking additional information like the clinical record, course, and final diagnosis into account. This consensus reading served as a reference. Statistics were carried out for diagnostic accuracy. Brain hemorrhage detection was executed successfully in 432/435 (99%) of patient cases. The AI algorithm and reference standard were consistent in 392 (90.7%) cases. One false-negative case was identified within the 52 positive cases. However, 39 positive detections turned out to be false positives. The diagnostic performance was calculated as a sensitivity of 98.1%, specificity of 89.7%, positive predictive value of 56.7%, and negative predictive value (NPV) of 99.7%. The execution of scanner-integrated AI detection of brain hemorrhages is feasible and robust. The diagnostic accuracy has a high specificity and a very high negative predictive value and sensitivity. However, many false-positive findings resulted in a relatively moderate positive predictive value.

17.
Cancers (Basel) ; 15(18)2023 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-37760588

RESUMEN

We introduce a deep-learning- and a registration-based method for automatically analyzing the spatial distribution of nodal metastases (LNs) in head and neck (H/N) cancer cohorts to inform radiotherapy (RT) target volume design. The two methods are evaluated in a cohort of 193 H/N patients/planning CTs with a total of 449 LNs. In the deep learning method, a previously developed nnU-Net 3D/2D ensemble model is used to autosegment 20 H/N levels, with each LN subsequently being algorithmically assigned to the closest-level autosegmentation. In the nonrigid-registration-based mapping method, LNs are mapped into a calculated template CT representing the cohort-average patient anatomy, and kernel density estimation is employed to estimate the underlying average 3D-LN probability distribution allowing for analysis and visualization without prespecified level definitions. Multireader assessment by three radio-oncologists with majority voting was used to evaluate the deep learning method and obtain the ground-truth distribution. For the mapping technique, the proportion of LNs predicted by the 3D probability distribution for each level was calculated and compared to the deep learning and ground-truth distributions. As determined by a multireader review with majority voting, the deep learning method correctly categorized all 449 LNs to their respective levels. Level 2 showed the highest LN involvement (59.0%). The level involvement predicted by the mapping technique was consistent with the ground-truth distribution (p for difference 0.915). Application of the proposed methods to multicenter cohorts with selected H/N tumor subtypes for informing optimal RT target volume design is promising.

18.
Diagnostics (Basel) ; 12(8)2022 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-36010211

RESUMEN

The aim of this study was to assess the diagnostic value of ADC distribution curves for differentiation between benign and malignant parotid gland tumors and to compare with mean ADC values. 73 patients with parotid gland tumors underwent head-and-neck MRI on a 1.5 Tesla scanner prior to surgery and histograms of ADC values were extracted. Histopathological results served as a reference standard for further analysis. ADC histograms were evaluated by comparing their similarity to a reference distribution using Chi2-test-statistics. The assumed reference distribution for benign and malignant parotid gland lesions was calculated after pooling the entire ADC data. In addition, mean ADC values were determined. For both methods, we calculated and compared the sensitivity and specificity between benign and malignant parotid gland tumors and three subgroups (pleomorphic adenoma, Warthin tumor, and malignant lesions), respectively. Moreover, we performed cross-validation (CV) techniques to estimate the predictive performance between ADC distributions and mean values. Histopathological results revealed 30 pleomorphic adenomas, 22 Warthin tumors, and 21 malignant tumors. ADC histogram distribution yielded a better specificity for detection of benign parotid gland lesions (ADChistogram: 75.0% vs. ADCmean: 71.2%), but mean ADC values provided a higher sensitivity (ADCmean: 71.4% vs. ADChistogram: 61.9%). The discrepancies are most pronounced in the differentiation between malignant and Warthin tumors (sensitivity ADCmean: 76.2% vs. ADChistogram: 61.9%; specificity ADChistogram: 81.8% vs. ADCmean: 68.2%). Using CV techniques, ADC distribution revealed consistently better accuracy to differentiate benign from malignant lesions ("leave-one-out CV" accuracy ADChistogram: 71.2% vs. ADCmean: 67.1%). ADC histogram analysis using full distribution curves is a promising new approach for differentiation between primary benign and malignant parotid gland tumors, especially with respect to the advantage in predictive performance based on CV techniques.

19.
Diagnostics (Basel) ; 11(10)2021 Oct 04.
Artículo en Inglés | MEDLINE | ID: mdl-34679533

RESUMEN

To evaluate patients' radiation exposure undergoing CT-guided joint injection in preparation of MR-arthrography. We developed a novel ultra-low-dose protocol utilizing tin-filtration, performed it in 60 patients and compared the radiation exposure (DLP) and success rate to conventional protocol (26 cases) and low-dose protocol (37 cases). We evaluated 123 patients' radiation exposure undergoing CT-guided joint injection from 16 January-21 March. A total of 55 patients received CT-guided joint injections with various other examination protocols and were excluded from further investigation. In total, 56 patients received shoulder injection and 67 received hip injection with consecutive MR arthrography. The ultra-low-dose protocol was performed in 60 patients, the low-dose protocol in 37 patients and the conventional protocol in 26 patients. We compared the dose of the interventional scans for each protocol (DLP) and then evaluated success rate with MR-arthrography images as gold standard of intraarticular or extracapsular contrast injection. There were significant differences when comparing the DLP of the ultra-low-dose protocol (DLP 1.1 ± 0.39; p < 0.01) to the low dose protocol (DLP 5.3 ± 3.24; p < 0.01) as well as against the conventional protocol (DLP 22.9 ± 8.66; p < 0.01). The ultra-low-dose protocol exposed the patients to an average effective dose of 0.016 millisievert and resulted in a successful joint injection in all 60 patients. The low dose protocol as well as the conventional protocol were also successful in all patients. The presented ultra-low-dose CT-guided joint injection protocol for the preparation of MR-arthrography demonstrated to reduce patients' radiation dose in a way that it was less than the equivalent of the natural radiation exposure in Germany over 3 days-and thereby, negligible to the patient.

20.
Diagnostics (Basel) ; 11(6)2021 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-34208499

RESUMEN

This study aimed to evaluate the radiation exposure to the radiologist and the procedure time of prospectively matched CT interventions implementing three different workflows-the radiologist-(I) leaving the CT room during scanning; (II) wearing a lead apron and staying in the CT room; (III) staying in the CT room in a prototype radiation protection cabin without lead apron while utilizing a wireless remote control and a tablet. We prospectively evaluated the radiologist's radiation exposure utilizing an electronic personal dosimeter, the intervention time, and success in CT interventions matched to the three different workflows. We compared the interventional success, the patient's dose of the interventional scans in each workflow (total mAs and total DLP), the radiologist's personal dose (in µSV), and interventional time. To perform workflow III, a prototype of a radiation protection cabin, with 3 mm lead equivalent walls and a foot switch to operate the doors, was built in the CT examination room. Radiation exposure during the maximum tube output at 120 kV was measured by the local admission officials inside the cabin at the same level as in the technician's control room (below 0.5 µSv/h and 1 mSv/y). Further, to utilize the full potential of this novel workflow, a sterile packed remote control (to move the CT table and to trigger the radiation) and a sterile packed tablet anchored on the CT table (to plan and navigate during the CT intervention) were operated by the radiologist. There were 18 interventions performed in workflow I, 16 in workflow II, and 27 in workflow III. There were no significant differences in the intervention time (workflow I: 23 min ± 12, workflow II: 20 min ± 8, and workflow III: 21 min ± 10, p = 0.71) and the patient's dose (total DLP, p = 0.14). However, the personal dosimeter registered 0.17 ± 0.22 µSv for workflow II, while I and III both documented 0 µSv, displaying significant difference (p < 0.001). All workflows were performed completely and successfully in all cases. The new workflow has the potential to reduce interventional CT radiologists' radiation dose to zero while relieving them from working in a lead apron all day.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA