Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Stroke ; 49(11): 2777-2779, 2018 11.
Artículo en Inglés | MEDLINE | ID: mdl-30355193

RESUMEN

Background and Purpose- Transthoracic echocardiography (TTE) is widely used in the ischemic stroke setting. In this study, we aim to investigate the yield of TTE in patients with ischemic stroke and known subtype and whether the admission troponin level improves the yield of TTE. Methods- Data were abstracted from a single-center prospective ischemic stroke database for 18 months and included all patients with ischemic stroke whose etiologic subtype could be obtained without the need of TTE. Unadjusted and adjusted regression models were built to determine whether positive cardiac troponin levels (≥0.1 ng/mL) improve the yield of TTE, adjusting for demographic and clinical characteristics. Results- We identified 578 patients who met the inclusion criteria. TTE changed clinical management in 64 patients (11.1%), but intracardiac thrombus was detected in only 4 patients (0.7%). In multivariable models, there was an association between TTE changing management and positive serum troponin level (adjusted odds ratio, 4.26; 95% CI, 2.17-8.34; P<0.001). Conclusions- In patients with ischemic stroke, TTE might lead to a change in clinical management in ≈1 of 10 patients with known stroke subtype before TTE but changed acute treatment decisions in <1 percent of patients. Serum troponin levels improved the yield of TTE in these patients.


Asunto(s)
Isquemia Encefálica/terapia , Cardiopatías/diagnóstico por imagen , Accidente Cerebrovascular/terapia , Troponina/sangre , Anciano , Anciano de 80 o más Años , Fibrilación Atrial/sangre , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Isquemia Encefálica/etiología , Enfermedades de los Pequeños Vasos Cerebrales/terapia , Bases de Datos Factuales , Manejo de la Enfermedad , Ecocardiografía , Femenino , Cardiopatías/sangre , Cardiopatías/complicaciones , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Accidente Cerebrovascular/etiología
2.
Stroke ; 49(1): 121-126, 2018 01.
Artículo en Inglés | MEDLINE | ID: mdl-29167390

RESUMEN

BACKGROUND AND PURPOSE: Elevated cardiac troponin is a marker of cardiac disease and has been recently shown to be associated with embolic stroke risk. We hypothesize that early elevated troponin levels in the acute stroke setting are more prevalent in patients with embolic stroke subtypes (cardioembolic and embolic stroke of unknown source) as opposed to noncardioembolic subtypes (large-vessel disease, small-vessel disease, and other). METHODS: We abstracted data from our prospective ischemic stroke database and included all patients with ischemic stroke during an 18-month period. Per our laboratory, we defined positive troponin as ≥0.1 ng/mL and intermediate as ≥0.06 ng/mL and <0.1 ng/mL. Unadjusted and adjusted regression models were built to determine the association between stroke subtype (embolic stroke of unknown source and cardioembolic subtypes) and positive and intermediate troponin levels, adjusting for key confounders, including demographics (age and sex), clinical characteristics (hypertension, hyperlipidemia, diabetes mellitus, renal function, coronary heart disease, congestive heart failure, current smoking, and National Institutes of Health Stroke Scale score), cardiac variables (left atrial diameter, wall-motion abnormalities, ejection fraction, and PR interval on ECG), and insular involvement of infarct. RESULTS: We identified 1234 patients, of whom 1129 had admission troponin levels available; 10.0% (113/1129) of these had a positive troponin. In fully adjusted models, there was an association between troponin positivity and embolic stroke of unknown source subtype (adjusted odds ratio, 4.46; 95% confidence interval, 1.03-7.97; P=0.003) and cardioembolic stroke subtype (odds ratio, 5.00; 95% confidence interval, 1.83-13.63; P=0.002). CONCLUSIONS: We found that early positive troponin after ischemic stroke may be independently associated with a cardiac embolic source. Future studies are needed to confirm our findings using high-sensitivity troponin assays and to test optimal secondary prevention strategies in patients with embolic stroke of unknown source and positive troponin.


Asunto(s)
Isquemia Encefálica , Embolia , Cardiopatías , Sistema de Registros , Accidente Cerebrovascular , Troponina/sangre , Anciano , Biomarcadores , Isquemia Encefálica/sangre , Isquemia Encefálica/complicaciones , Embolia/sangre , Embolia/etiología , Femenino , Cardiopatías/sangre , Cardiopatías/etiología , Humanos , Masculino , Estudios Prospectivos , Factores de Riesgo , Accidente Cerebrovascular/sangre , Accidente Cerebrovascular/complicaciones
3.
J Stroke Cerebrovasc Dis ; 27(6): 1692-1696, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29501269

RESUMEN

BACKGROUND: Occult paroxysmal atrial fibrillation (AF) is detected in 16%-30% of patients with embolic stroke of unknown source (ESUS). The identification of AF predictors on outpatient cardiac monitoring can help guide clinicians decide on a duration or method of cardiac monitoring after ESUS. METHODS: We included all patients with ESUS who underwent an inpatient diagnostic evaluation and outpatient cardiac monitoring between January 1, 2013, and December 31, 2016. Patients were divided into 2 groups based on detection of AF or atrial flutter during monitoring. We compared demographic data, clinical risk factors, and cardiac biomarkers between the 2 groups. Multivariable logistic regression was used to determine predictors of AF. RESULTS: We identified 296 consecutive patients during the study period; 38 (12.8%) patients had AF detected on outpatient cardiac monitoring. In a multivariable regression analysis, advanced age (ages 65-74: odds ratio [OR] 2.36, 95% confidence interval [CI] .85-6.52; ages 75 or older: OR 4.08, 95% CI 1.58-10.52) and moderate-to-severe left atrial enlargement (OR 4.66, 95% CI 1.79-12.12) were predictors of AF on outpatient monitoring. We developed the Brown ESUS-AF score: age (65-74 years: 1 point, 75 years or older: 2 points) and left atrial enlargement (moderate or severe: 2 points) with good prediction of AF (area under the curve .725) and was internally validated using bootstrapping. The percentage of patients with AF detected in each score category were as follows: 0: 4.2%; 1: 14.8%; 2: 20.8%; 3: 22.2%; 4: 55.6%. CONCLUSIONS: The Brown ESUS-AF score predicts AF on prolonged outpatient monitoring after ESUS. More studies are needed to externally validate our findings.


Asunto(s)
Atención Ambulatoria , Fibrilación Atrial/complicaciones , Aleteo Atrial/complicaciones , Técnicas de Apoyo para la Decisión , Embolia Intracraneal/etiología , Monitoreo Ambulatorio/métodos , Accidente Cerebrovascular/etiología , Factores de Edad , Anciano , Anciano de 80 o más Años , Área Bajo la Curva , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Aleteo Atrial/diagnóstico , Aleteo Atrial/fisiopatología , Cardiomegalia/complicaciones , Distribución de Chi-Cuadrado , Toma de Decisiones Clínicas , Ecocardiografía , Electrocardiografía , Femenino , Humanos , Embolia Intracraneal/diagnóstico , Embolia Intracraneal/fisiopatología , Modelos Logísticos , Masculino , Persona de Mediana Edad , Análisis Multivariante , Oportunidad Relativa , Valor Predictivo de las Pruebas , Curva ROC , Sistema de Registros , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Riesgo , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular/fisiopatología , Factores de Tiempo
4.
Catheter Cardiovasc Interv ; 90(7): 1115-1116, 2017 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-29226575

RESUMEN

Intravascular imaging plays a key role in the identification of mechanisms of acute coronary syndromes Post processing IVUS algorithms (IMAP-IVUS and VH-IVUS) for tissue characterization have not been widely adopted due to current limitations Future development will allow easier, faster, and more accurate identification of vulnerable plaques, ultimately allowing prognostication of various interventions.


Asunto(s)
Síndrome Coronario Agudo , Infarto del Miocardio , Humanos , Fenotipo , Ultrasonografía Intervencional
5.
Curr Atheroscler Rep ; 18(5): 26, 2016 May.
Artículo en Inglés | MEDLINE | ID: mdl-27005804

RESUMEN

Historically, the relationship between exercise and the cardiovascular system was viewed as unidirectional, with a disease resulting in exercise limitation and hazard. This article reviews and explores the bidirectional nature, delineating the effects, generally positive, on the cardiovascular system and atherosclerosis. Exercise augments eNOS, affects redox potential, and favorably affects mediators of atherosclerosis including lipids, glucose homeostasis, and inflammation. There are direct effects on the vasculature as well as indirect benefits related to exercise-induced changes in body composition and skeletal muscle. Application of aerobic exercise to specific populations is described, with the hope that this knowledge will move the science forward and improve individual patient outcome.


Asunto(s)
Aterosclerosis/fisiopatología , Sistema Cardiovascular , Aptitud Física , Aterosclerosis/complicaciones , Composición Corporal , Enfermedades Cardiovasculares/etiología , Ejercicio Físico/fisiología , Humanos
6.
J Interv Cardiol ; 28(5): 449-55, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26489972

RESUMEN

OBJECTIVES: To evaluate the impact of robotic-assisted percutaneous coronary intervention (RA-PCI) versus manual PCI (M-PCI) on the incidence of Longitudinal Geographic Miss (LGM). BACKGROUND: The safety and feasibility of RA-PCI has been established in preclinical animal trials and human clinical trials. Patients with LGM have been shown to have worse clinical outcomes including significantly increased incidences of MACE. METHODS: Patients with significant coronary artery disease underwent RA-PCI in the PRECISE study (n=164) and standard M-PCI in the STLLR trial (n = 1,509). Longitudinal geographic miss was defined as cases where the entire length of the injured or stenotic segment was not fully covered by the total length of the stent. The incidence of LGM was compared between RA-PCI and M-PCI cohorts. RESULTS: The RA-PCI cohort had a significantly greater prevalence of previous MI, previous coronary revascularization, and unstable angina. The robotic cohort exhibited a lower incidence of LGM when compared to the M-PCI patients, 12.2% to 43.1%, respectively (P < 0.0001). To account for the differences in baseline characteristics between the two studies, a propensity score analysis was conducted. The propensity modeling showed similar rates of LGM in both a larger group of patients that met key PRECISE study inclusion/exclusion criteria adjusted for propensity score (9.3% vs 55.0%; P < 0.0001) and in a smaller, matched on propensity score, subset of patients (10.3% vs 64.1%; P < 0.0001). CONCLUSION: Robotic-assisted PCI had significantly lower incidence of LGM compared to standard M-PCI. Reducing LGM potentially improves long-term clinical outcomes through reduction in MACE.


Asunto(s)
Enfermedad de la Arteria Coronaria , Intervención Coronaria Percutánea , Falla de Prótesis/etiología , Procedimientos Quirúrgicos Robotizados , Stents/efectos adversos , Anciano , Investigación sobre la Eficacia Comparativa , Angiografía Coronaria/métodos , Angiografía Coronaria/estadística & datos numéricos , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/cirugía , Femenino , Humanos , Incidencia , Israel , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/instrumentación , Intervención Coronaria Percutánea/métodos , Puntaje de Propensión , Procedimientos Quirúrgicos Robotizados/efectos adversos , Procedimientos Quirúrgicos Robotizados/métodos , Robótica , Resultado del Tratamiento , Estados Unidos
7.
Catheter Cardiovasc Interv ; 81(3): 568-72, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22511464

RESUMEN

Optical coherence tomography (OCT) offers an alternative to intravascular ultrasound (IVUS) for endovascular imaging. Clinical and research applications for OCT have emerged in percutaneous coronary intervention (PCI), however, OCT has not found similar utility in peripheral arterial interventions. Early generation time-domain OCT systems required arterial occlusion to create the blood free environment needed for image acquisition and could not reliably scan vessel diameters encountered in the peripheral circulation. However, the frequency-domain OCT (FD-OCT) system currently FDA approved for use in the United States does not require arterial occlusion to generate images and permits a greater scan diameter allowing for exploratory use in peripheral arteries. To our knowledge, this is the first report using non-occlusive OCT imaging to serve as an adjunct to endovascular intervention for femoropopliteal disease. We illustrate the feasibility of acquiring high resolution images of a spiral dissection of the superficial femoral artery following balloon angioplasty that was not adequately visualized by angiography.


Asunto(s)
Disección Aórtica/diagnóstico , Arteria Femoral/patología , Aumento de la Imagen , Enfermedad Arterial Periférica/diagnóstico , Tomografía de Coherencia Óptica/métodos , Disección Aórtica/cirugía , Prótesis Vascular , Diagnóstico Diferencial , Arteria Femoral/cirugía , Humanos , Masculino , Persona de Mediana Edad , Enfermedad Arterial Periférica/cirugía , Stents
8.
Catheter Cardiovasc Interv ; 82(3): E173-83, 2013 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-23359350

RESUMEN

OBJECTIVES: To investigate safety and feasibility of imaging unprotected left main (ULM) using frequency-domain optical coherence tomography (FD-OCT) compared with intravascular ultrasound (IVUS). BACKGROUND: IVUS has been used to assess and guide percutaneous coronary intervention (PCI) of ULM disease. FD-OCT offers 10-fold higher axial resolution than IVUS and its high-speed image acquisition obviates the need for proximal balloon occlusion. METHODS: We prospectively enrolled 35 consecutive patients with ULM disease. FD-OCT and IVUS assessments were attempted pre- and post-PCI and compared in regards to safety, ability to image the region of interest (ROI), number of pullbacks, volume of contrast and ability to detect malapposition, dissection, and thrombus. RESULTS: Patients were followed for 1 year when FD-OCT imaging was repeated. FD-OCT required more repeated pullbacks to image the ROI compared to IVUS. Mean lumen and stent areas were similar between FD-OCT and IVUS (11.24 ± 2.66 vs. 10.85 ± 2.47 mm(2) , P = 0.13 and 10.44 ± 2.33 vs. 10.49 ± 2.32 mm(2) , P = 0.82, respectively), whereas imaged stent length was shorter with FD-OCT. Malapposition areas and volumes were larger and more edge dissections were detected by FD-OCT. There were no clinical adverse events and no complications associated with FD-OCT at baseline and 1-year follow-up. All dissections were healed, whereas stent malapposition was still detected at follow-up. CONCLUSIONS: FD-OCT assessment of ULM is feasible and safe. Direct comparisons with IVUS reveal that FD-OCT achieved imaging completeness less often, whereas it was more sensitive in detecting malapposition and edge dissections, and similar to IVUS in the assessment of lumen and stent dimensions.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Tomografía de Coherencia Óptica , Ultrasonografía Intervencional , Anciano , Medios de Contraste , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/patología , Enfermedad de la Arteria Coronaria/terapia , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/instrumentación , Proyectos Piloto , Valor Predictivo de las Pruebas , Estudios Prospectivos , Factores de Riesgo , Índice de Severidad de la Enfermedad , Stents , Factores de Tiempo , Tomografía de Coherencia Óptica/efectos adversos , Resultado del Tratamiento , Ultrasonografía Intervencional/efectos adversos , Cicatrización de Heridas
9.
Circ J ; 77(9): 2334-40, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-23782524

RESUMEN

BACKGROUND: Coronary artery calcification (CAC) presents unique challenges for percutaneous coronary intervention. Calcium appears as a signal-poor region with well-defined borders by frequency-domain optical coherence tomography (FD-OCT). The objective of this study was to demonstrate the accuracy of intravascular FD-OCT to determine the distribution of CAC. METHODS AND RESULTS: Cadaveric coronary arteries were imaged using FD-OCT at 100-µm frame interval. Arteries were subsequently frozen, sectioned and imaged at 20-µm intervals using the Case Cryo-Imaging automated system(TM). Full volumetric co-registration between FD-OCT and cryo-imaging was performed. Calcium area, calcium-lumen distance (depth) and calcium angle were traced on every cross-section; volumetric quantification was performed offline. In total, 30 left anterior descending arteries were imaged: 13 vessels had a total of 55 plaques with calcification by cryo-imaging; FD-OCT identified 47 (85%) of these plaques. A total of 1,285 cryo-images were analyzed and compared with corresponding co-registered 257 FD-OCT images. Calcium distribution, represented by the mean depth and the mean calcium angle, was similar, with excellent correlation between FD-OCT and cryo-imaging respectively (mean depth: 0.25±0.09 vs. 0.26±0.12mm, P=0.742; R=0.90), (mean angle: 35.33±21.86° vs. 39.68±26.61°, P=0.207; R=0.90). Calcium volume was underestimated in large calcifications (3.11±2.14 vs. 4.58±3.39mm(3), P=0.001) in OCT vs. cryo respectively. CONCLUSIONS: Intravascular FD-OCT can accurately characterize CAC distribution. OCT can quantify absolute calcium volume, but may underestimate calcium burden in large plaques with poorly defined abluminal borders.


Asunto(s)
Calcio , Enfermedad de la Arteria Coronaria , Vasos Coronarios , Placa Aterosclerótica , Tomografía de Coherencia Óptica , Calcificación Vascular , Anciano , Enfermedad de la Arteria Coronaria/metabolismo , Enfermedad de la Arteria Coronaria/patología , Vasos Coronarios/metabolismo , Vasos Coronarios/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Placa Aterosclerótica/metabolismo , Placa Aterosclerótica/patología , Calcificación Vascular/metabolismo , Calcificación Vascular/patología
10.
Circ J ; 75(9): 2113-9, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21757826

RESUMEN

BACKGROUND: Geographical miss (GM), representing suboptimal drug-eluting stent deployment, is associated with an increased risk of target lesion revascularization (TLR) and myocardial infarction. The impact of suboptimal stenting techniques on clinical outcomes in diabetics remains unknown. METHODS AND RESULTS: Stent deployment Techniques on cLinicaL outcomes of patients treated with the cypheR(TM) stent (STLLR) is the first multicenter, large trial to prospectively evaluate outcomes associated with sirolimus-eluting stent (SES) deployment techniques. Axial GM and longitudinal GM (LGM), defined as a balloon injured segment or a diseased segment not covered by a SES, were assessed by an independent core laboratory. One-year outcomes between diabetics and non-diabetics and their relationship with GM were assessed. This substudy included 1,336 patients, 28.8% with diabetes. In non-LGM patients, TLR was similarly low in both diabetics and non-diabetics (2.0% vs. 2.0%, P=NS). However, TLR increased 4.1 times in diabetics (8.0%) and 1.9 times in non-diabetics (3.8%) in the presence of LGM (P=0.03). Axial GM had no impact on outcomes. By univariate analysis, stent length, acute gain, and LGM were the predictors of TLR in the total cohort. However, by multivariate analysis, acute gain was the only predictor of TLR (P=0.03), independently of LGM or diabetes. CONCLUSIONS: Acute gain is the exclusive predictor of TLR after SES implantation. Particularly in diabetics, the negative impact of LGM on TLR seems to be amplified. Diligent SES deployment for larger acute gain is critical to improve clinical outcomes.


Asunto(s)
Complicaciones de la Diabetes/terapia , Stents Liberadores de Fármacos/efectos adversos , Oclusión de Injerto Vascular/etiología , Inmunosupresores/efectos adversos , Infarto del Miocardio/terapia , Sirolimus/efectos adversos , Complicaciones de la Diabetes/epidemiología , Estudios de Seguimiento , Oclusión de Injerto Vascular/epidemiología , Humanos , Inmunosupresores/farmacología , Masculino , Persona de Mediana Edad , Infarto del Miocardio/epidemiología , Estudios Prospectivos , Sirolimus/farmacología
11.
Biomed Opt Express ; 12(12): 7500-7516, 2021 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-35003848

RESUMEN

Coronary stenting or percutaneous coronary intervention (PCI) is widely used to treat coronary artery disease. Improper deployment of stents may lead to post-PCI complication, in-stent restenosis, stent fracture and stent thrombosis. Intravascular optical coherence tomography (OCT) with micron-scale resolution provides accurate in vivo assessment of stent apposition/malapposition and neointima coverage. However, manual stent analysis is labor intensive and time consuming. Existing automated methods with intravascular OCT mainly focused on stent struts with thin tissue coverage. We developed a deep learning method to automatically analyze stents with both thin (≤0.3mm) and very thick tissue coverage (>0.3mm), and an algorithm to accurately analyze stent area for vessels with multiple stents. 25203 images from 56 OCT pullbacks and 41 patients were analyzed. Three-fold cross-validation demonstrated that the algorithm achieved a precision of 0.932±0.009 and a sensitivity of 0.939±0.007 for stents with ≤0.3mm tissue coverage, and a precision of 0.856±0.019 and a sensitivity of 0.874±0.011 for stents with >0.3mm tissue coverage. The correlation between the automatically computed and manually measured stent area is 0.954 (p<0.0001) for vessels with a single stent, and is 0.918 (p<0.0001) for vessels implanted with multiple stents. The proposed method can accurately detect stent struts with very thick tissue coverage and analyze stent area in vessels implanted with multiple stents, and can effectively facilitate the evaluation of stent implantation and post-stent tissue coverage.

12.
J Biomed Opt ; 24(10): 1-15, 2019 10.
Artículo en Inglés | MEDLINE | ID: mdl-31586357

RESUMEN

We developed machine learning methods to identify fibrolipidic and fibrocalcific A-lines in intravascular optical coherence tomography (IVOCT) images using a comprehensive set of handcrafted features. We incorporated features developed in previous studies (e.g., optical attenuation and A-line peaks). In addition, we included vascular lumen morphology and three-dimensional (3-D) digital edge and texture features. Classification methods were developed using expansive datasets (∼7000 images), consisting of both clinical in-vivo images and an ex-vivo dataset, which was validated using 3-D cryo-imaging/histology. Conditional random field was used to perform 3-D classification noise cleaning of classification results. We tested various multiclass approaches, classifiers, and feature selection schemes and found that a three-class support vector machine with minimal-redundancy-maximal-relevance feature selection gave the best performance. We found that inclusion of our morphological and 3-D features improved overall classification accuracy. On a held-out test set consisting of >1700 images, we obtained an overall accuracy of 81.58%, with the following (sensitivity/specificity) for each class: other (81.43/89.59), fibrolipidic (94.48/87.32), and fibrocalcific (74.82/95.28). The en-face views of classification results showed that automated classification easily captured the preponderance of a disease segment (e.g., a calcified segment had large regions of fibrocalcific classifications). Finally, we demonstrated proof-of-concept for streamlining A-line classification output with existing fibrolipidic and fibrocalcific boundary segmentation methods, to enable fully automated plaque quantification. The results suggest that our classification approach is a viable step toward fully automated IVOCT plaque classification and segmentation for live-time treatment planning and for offline assessment of drug and biologic therapeutics.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Interpretación de Imagen Asistida por Computador/métodos , Aprendizaje Automático , Placa Aterosclerótica/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos , Algoritmos , Vasos Coronarios/diagnóstico por imagen , Bases de Datos Factuales , Procedimientos Endovasculares , Humanos , Máquina de Vectores de Soporte
13.
BMC Res Notes ; 10(1): 681, 2017 Dec 04.
Artículo en Inglés | MEDLINE | ID: mdl-29202817

RESUMEN

BACKGROUND: Right atrial appendage aneurysms are rare entities that may have significant clinical consequences. When co-existing with atrial fibrillation, patients are at risk of developing pulmonary or paradoxical systemic emboli. CASE PRESENTATION: An elderly patient presented to medical attention with symptoms of acute diverticulitis. On abdominal computed tomography, a massively enlarged right atrial appendage aneurysm was discovered incidentally. The aneurysm caused marked compression of the right ventricle and contained an area of hypoenhancement concerning for an intraluminal thrombus. Gadolinium-enhanced cardiovascular magnetic resonance was performed and first-pass perfusion images demonstrated that the area of hypoenhancement was in fact poorly mixing blood. The patient was therefore managed medically. CONCLUSION: Right atrial appendage aneurysms are infrequently encountered cardiac abnormalities. In the literature, surgery has been offered to patients who are young, symptomatic, or have evidence of thrombotic disease, although whether this practice pattern is associated with superior clinical outcomes is unclear. In the present case, gadolinium-enhanced cardiovascular magnetic resonance imaging was used to exclude the presence of intraluminal thrombus in an elderly patient, which helped orient the patient's treating team towards medical-rather than surgical-therapy.


Asunto(s)
Dolor Abdominal/diagnóstico por imagen , Apéndice Atrial/diagnóstico por imagen , Diverticulitis/diagnóstico por imagen , Aneurisma Cardíaco/diagnóstico por imagen , Trombosis/diagnóstico por imagen , Dolor Abdominal/complicaciones , Dolor Abdominal/patología , Enfermedad Aguda , Anciano , Apéndice Atrial/patología , Diverticulitis/complicaciones , Diverticulitis/patología , Aneurisma Cardíaco/complicaciones , Aneurisma Cardíaco/patología , Humanos , Hallazgos Incidentales , Imagen por Resonancia Magnética , Trombosis/complicaciones , Trombosis/patología , Tomografía Computarizada por Rayos X
14.
Interv Cardiol Clin ; 5(3): 281-293, 2016 07.
Artículo en Inglés | MEDLINE | ID: mdl-28582027

RESUMEN

Restenosis is a pathologic response to vascular injury, characterized by neointimal hyperplasia and progressive narrowing of a stented vessel segment. Although advances in stent design have led to a dramatic reduction in the incidence of restenosis, it continues to represent the most common cause of target lesion failure following percutaneous coronary intervention. Efforts to maximize restenosis prevention, through careful consideration of modifiable risk factors and an individualized approach, are critical, as restenosis, once established, can be particularly difficult to treat. Novel approaches are on the horizon that have the potential to alter the natural history of this stubborn disease.


Asunto(s)
Reestenosis Coronaria/cirugía , Stents , Constricción Patológica/prevención & control , Constricción Patológica/cirugía , Angiografía Coronaria , Reestenosis Coronaria/prevención & control , Vasos Coronarios/patología , Humanos , Hiperplasia , Neointima
15.
Int J Cardiol ; 218: 43-46, 2016 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-27232910

RESUMEN

BACKGROUND: Persons living with HIV are at a higher risk of cardiovascular disease despite effective antiretroviral therapy and dramatic reductions in AIDS-related conditions. We sought to identify the epidemiology of heart failure (HF) among persons living with HIV in the United States in an era of contemporary antiretroviral therapy. METHODS: Explorys is an electronic healthcare database that aggregates medical records from 23 healthcare systems nationwide. Using systemized nomenclature of medicine-clinical terms (SNOMED-CT), we identified adult patients (age>18), who had active records over the past year (September 2014-September 2015). We described the prevalence of HF in HIV patients by demographics and treatment and compared them to HIV-uninfected controls. RESULTS: Overall, there were 36,400 patients with HIV and 12,208,430 controls. The overall prevalence of HF was 7.2% in HIV and 4.4% in controls (RR 1.66 [1.60-1.72], p<0.0001). The relative risk of HF associated with HIV infection was higher among women and younger age groups. Patients receiving antiretroviral therapy had only marginally lower risk (6.4% vs. 7.7%, p<0.0001) of HF compared to those who were untreated. Compared to uninfected patients with HF, HIV patients with HF were less likely to receive antiplatelet drugs, statins, diuretics, and ACE/ARBs (p<0.0001 for all comparisons). For patients with HIV and HF, receiving care from a cardiologist was associated with higher use of antiplatelets, statins, betablockers, ACE/ARBs, and diuretics. CONCLUSIONS: Persons with HIV are at higher risk for HF in this large contemporary sample that includes both men and women. Although the prevalence of heart failure is higher in older HIV patients, the relative risk associated with HIV is highest in young people and in women. HIV patients are less likely to have HF optimally treated, but cardiology referral was associated with higher treatment rates.


Asunto(s)
Manejo de la Enfermedad , Infecciones por VIH/tratamiento farmacológico , Infecciones por VIH/epidemiología , Disparidades en Atención de Salud , Insuficiencia Cardíaca/tratamiento farmacológico , Insuficiencia Cardíaca/epidemiología , Adulto , Anciano , Antirretrovirales/uso terapéutico , Fármacos Cardiovasculares/uso terapéutico , Estudios de Cohortes , Bases de Datos Factuales/tendencias , Registros Electrónicos de Salud/tendencias , Femenino , Infecciones por VIH/diagnóstico , Disparidades en Atención de Salud/tendencias , Insuficiencia Cardíaca/diagnóstico , Humanos , Masculino , Persona de Mediana Edad , Sistema de Registros , Estudios Retrospectivos , Estados Unidos/epidemiología , Adulto Joven
16.
Arq Bras Cardiol ; 106(5): 419-21, 2016 May.
Artículo en Inglés, Portugués | MEDLINE | ID: mdl-27305286

RESUMEN

Optical coherence tomography (OCT) has become the invasive imaging modality of choice for coronary stent assessment due to its unmatched spatial resolution. Neointimal calcification (NC) is a rare finding, observed in 5-10% of in-stent restenosis (ISR) neointima. The impact of NC on percutaneous coronary intervention of ISR is unknown. We therefore present the outcome of six unique cases of ISR and NC in which OCT was used to evaluate the impact of NC on the quality of stent-in-stent deployment for the treatment of ISR. This series demonstrates for the first time the impact of NC on stent expansion, a finding which might help guiding percutaneous coronary intervention for ISR with NC.


Asunto(s)
Reestenosis Coronaria/diagnóstico por imagen , Neointima/diagnóstico por imagen , Stents , Calcificación Vascular/diagnóstico por imagen , Reestenosis Coronaria/terapia , Humanos , Stents/efectos adversos , Tomografía de Coherencia Óptica
17.
J Med Imaging (Bellingham) ; 3(2): 026004, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-27429997

RESUMEN

Evidence suggests high-resolution, high-contrast, [Formula: see text] intravascular optical coherence tomography (IVOCT) can distinguish plaque types, but further validation is needed, especially for automated plaque characterization. We developed experimental and three-dimensional (3-D) registration methods to provide validation of IVOCT pullback volumes using microscopic, color, and fluorescent cryo-image volumes with optional registered cryo-histology. A specialized registration method matched IVOCT pullback images acquired in the catheter reference frame to a true 3-D cryo-image volume. Briefly, an 11-parameter registration model including a polynomial virtual catheter was initialized within the cryo-image volume, and perpendicular images were extracted, mimicking IVOCT image acquisition. Virtual catheter parameters were optimized to maximize cryo and IVOCT lumen overlap. Multiple assessments suggested that the registration error was better than the [Formula: see text] spacing between IVOCT image frames. Tests on a digital synthetic phantom gave a registration error of only [Formula: see text] (signed distance). Visual assessment of randomly presented nearby frames suggested registration accuracy within 1 IVOCT frame interval ([Formula: see text]). This would eliminate potential misinterpretations confronted by the typical histological approaches to validation, with estimated 1-mm errors. The method can be used to create annotated datasets and automated plaque classification methods and can be extended to other intravascular imaging modalities.

18.
Proc SPIE Int Soc Opt Eng ; 97882016 Feb 27.
Artículo en Inglés | MEDLINE | ID: mdl-27162417

RESUMEN

High resolution, 100 frames/sec intravascular optical coherence tomography (IVOCT) can distinguish plaque types, but further validation is needed, especially for automated plaque characterization. We developed experimental and 3D registration methods, to provide validation of IVOCT pullback volumes using microscopic, brightfield and fluorescent cryo-image volumes, with optional, exactly registered cryo-histology. The innovation was a method to match an IVOCT pull-back images, acquired in the catheter reference frame, to a true 3D cryo-image volume. Briefly, an 11-parameter, polynomial virtual catheter was initialized within the cryo-image volume, and perpendicular images were extracted, mimicking IVOCT image acquisition. Virtual catheter parameters were optimized to maximize cryo and IVOCT lumen overlap. Local minima were possible, but when we started within reasonable ranges, every one of 24 digital phantom cases converged to a good solution with a registration error of only +1.34±2.65µm (signed distance). Registration was applied to 10 ex-vivo cadaver coronary arteries (LADs), resulting in 10 registered cryo and IVOCT volumes yielding a total of 421 registered 2D-image pairs. Image overlays demonstrated high continuity between vascular and plaque features. Bland-Altman analysis comparing cryo and IVOCT lumen area, showed mean and standard deviation of differences as 0.01±0.43 mm2. DICE coefficients were 0.91±0.04. Finally, visual assessment on 20 representative cases with easily identifiable features suggested registration accuracy within one frame of IVOCT (±200µm), eliminating significant misinterpretations introduced by 1mm errors in the literature. The method will provide 3D data for training of IVOCT plaque algorithms and can be used for validation of other intravascular imaging modalities.

19.
Artículo en Inglés | MEDLINE | ID: mdl-27582113

RESUMEN

BACKGROUND: There are few clinical studies on the pathophysiological mechanisms of very late stent thrombosis (VLST). We report optical coherence tomography findings in patients with VLST and compare the findings between bare-metal stents (BMS) and drug-eluting stents (DES). METHODS AND RESULTS: We conducted a registry of stent thrombosis at 4 North American centers with optical coherence tomography imaging programs SAFE registry (The Study of Late Stent Failure Evaluated by OCT). Images were acquired in 61 patients (42 DES and 19 BMS) presenting with definite VLST. The median duration from implantation to VLST presentation was 51.4 months in the DES and 69.9 months in the BMS group (P=0.011). Uncovered and malapposed struts were observed in 70.5% (43/61) and 62.3% (38/61) of patients, respectively, whereas neoatherosclerosis was revealed in 49.2% (30/61). Stent underexpansion was observed in 42.4% of patients. Malapposed struts and stent underexpansion were more frequently demonstrated in DES than in BMS patients, whereas neoatherosclerosis was frequently observed in BMS (40.5% in DES and 68.4% in BMS; P=0.056). The percentage of frames with neoatherosclerosis was lower in DES than in BMS (15.56% [12.24-28.57] versus, 56.41% [40.74-70.00], respectively; P<0.001). Maximum consecutive lipid neointima length was shorter in DES than in BMS (2.4 [1.2-3.6] and 5.3 [3.0-7.0] mm; P=0.011). CONCLUSIONS: Optical coherence tomography imaging demonstrated that VLST in DES and BMS had a wide variety of abnormal findings, such as neoatherosclerosis, uncovered strut, and malapposed strut. Neoatherosclerosis and lipid neointima were more frequently observed and had more longitudinal extension in BMS compared with DES.


Asunto(s)
Trombosis Coronaria/diagnóstico por imagen , Vasos Coronarios/diagnóstico por imagen , Stents Liberadores de Fármacos , Metales , Intervención Coronaria Percutánea/instrumentación , Placa Aterosclerótica , Stents , Tomografía de Coherencia Óptica , Anciano , Trombosis Coronaria/etiología , Trombosis Coronaria/patología , Vasos Coronarios/patología , Femenino , Humanos , Masculino , Persona de Mediana Edad , América del Norte , Intervención Coronaria Percutánea/efectos adversos , Valor Predictivo de las Pruebas , Diseño de Prótesis , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Insuficiencia del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA