1.
Sensors (Basel) ; 19(8)2019 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-31010121

RESUMEN

This paper presents a 10 to 20 GHz bandwidth microwave polarimeter demonstrator, based on the implementation of a near-infra-red frequency up-conversion stage that allows both the optical correlation, when operating as a synthesized-image interferometer, and signal detection, when operating as a direct-image instrument. The proposed idea is oriented towards the implementation of ultra-sensitive instruments presenting several dozens or even thousands of microwave receivers operating in the lowest bands of the cosmic microwave background. In this work, an electro-optical back-end module replaces the usual microwave detection stage with Mach-Zehnder modulators for the frequency up-conversion, and an optical stage for the signals correlation and detection at near-infra-red wavelengths (1550 nm). As interferometer, the instrument is able to correlate the signals of large-format instruments, while operating as a direct imaging instrument also presents advantages in terms of the possibility of implementing the optical back end by means of photonic integrated circuits to achieve reductions in cost, weight, size, and power consumption. A linearly polarized input wave, with a variable polar angle, is used as a signal source for laboratory tests. The receiver demonstrator has proved its capabilities of being used as a new microwave-photonic polarimeter for the study of the lowest bands of cosmic microwave background.

2.
Opt Express ; 24(26): 29994-30001, 2016 Dec 26.
Artículo en Inglés | MEDLINE | ID: mdl-28059384

RESUMEN

We demonstrate a Brillouin optical frequency-domain reflectometry (BOFDR) technique, which can measure the strain and/or temperature along an optical fiber with one-end access, by detecting the spontaneous Brillouin scattering from a sinusoidally modulated pump light. Compared to the Brillouin optical frequency-domain analysis (BOFDA), we show that BOFDR measurements are free from the distorting components related to acoustic wave modulation, thus simplifying data processing.

3.
Talanta ; 251: 123757, 2023 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-35981437

RESUMEN

The elemental composition of marine mollusk shells can offer valuable information about environmental conditions experienced by a mollusk during its lifespan. Previous studies have shown significant correlations between Mg/Ca concentration ratios measured on biogenic carbonate of mollusk shells and sea surface temperature (SST). Here we propose the use of Laser-Induced Breakdown Spectroscopy (LIBS) and the validation of the Calibration-Free LIBS (CF-LIBS) approach for the rapid measurement and estimation of Mg/Ca molar concentration profiles within Patella depressa Pennant, 1777 limpet shells. To achieve these objectives, results derived from CF-LIBS methodology are compared with those obtained from an established analytical technique for this purpose, such as Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS). Concentration series obtained with both methodologies show defined temporal patterns and reflect the season-of-capture in each specimen. The results evidence a significant correlation (R2 = 0.63-0.81) between CF-LIBS and LA-ICP-MS Mg/Ca molar concentration profiles within four live-collected P. depressa shells. Averaged error for the molar concentration estimated with CF-LIBS was lower than 10% in every specimen. The comparison between the results obtained from two techniques used in this study has allowed us to demonstrate for the first time that Mg/Ca molar concentration measured in biogenic carbonates were accurately inferred using CF-LIBS technique. The CF-LIBS approach validation represents great potential for the rapid and large-scale paleoenvironmental and archaeological analysis of this mollusk species, which is frequently found in archaeological sites.


Asunto(s)
Terapia por Láser , Rótula , Calibración , Rayos Láser , Análisis Espectral/métodos
4.
Appl Opt ; 48(24): 4735-42, 2009 Aug 20.
Artículo en Inglés | MEDLINE | ID: mdl-19696862

RESUMEN

An online welding quality system based on the use of imaging spectroscopy is proposed and discussed. Plasma optical spectroscopy has already been successfully applied in this context by establishing a direct correlation between some spectroscopic parameters, e.g., the plasma electronic temperature and the resulting seam quality. Given that the use of the so-called hyperspectral devices provides both spatial and spectral information, we propose their use for the particular case of arc welding quality monitoring in an attempt to determine whether this technique would be suitable for this industrial situation. Experimental welding tests are presented, and the ability of the proposed solution to identify simulated defects is proved. Detailed spatial analyses suggest that this additional dimension can be used to improve the performance of the entire system.

5.
Sensors (Basel) ; 9(7): 5263-5276, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-22346696

RESUMEN

A new spectroscopic parameter is used in this paper for on-line arc-welding quality monitoring. Plasma spectroscopy applied to welding diagnostics has typically relied on the estimation of the plasma electronic temperature, as there is a known correlation between this parameter and the quality of the seams. However, the practical use of this parameter gives rise to some uncertainties that could provoke ambiguous results. For an efficient on-line welding monitoring system, it is essential to prevent the appearance of false alarms, as well as to detect all the possible defects. In this regard, we propose the use of the root mean square signal of the welding plasma spectra, as this parameter will be proven to exhibit a good correlation with the quality of the resulting seams. Results corresponding to several arc-welding field tests performed on Inconel and titanium specimens will be discussed and compared to non-destructive evaluation techniques.

6.
Sensors (Basel) ; 9(10): 7753-70, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-22408478

RESUMEN

Plasma optical spectroscopy is widely employed in on-line welding diagnostics. The determination of the plasma electron temperature, which is typically selected as the output monitoring parameter, implies the identification of the atomic emission lines. As a consequence, additional processing stages are required with a direct impact on the real time performance of the technique. The line-to-continuum method is a feasible alternative spectroscopic approach and it is particularly interesting in terms of its computational efficiency. However, the monitoring signal highly depends on the chosen emission line. In this paper, a feature selection methodology is proposed to solve the uncertainty regarding the selection of the optimum spectral band, which allows the employment of the line-to-continuum method for on-line welding diagnostics. Field test results have been conducted to demonstrate the feasibility of the solution.

7.
Sensors (Basel) ; 8(10): 6496-6506, 2008 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-27873883

RESUMEN

A new spectral processing technique designed for application in the on-line detection and classification of arc-welding defects is presented in this paper. A noninvasive fiber sensor embedded within a TIG torch collects the plasma radiation originated during the welding process. The spectral information is then processed in two consecutive stages. A compression algorithm is first applied to the data, allowing real-time analysis. The selected spectral bands are then used to feed a classification algorithm, which will be demonstrated to provide an efficient weld defect detection and classification. The results obtained with the proposed technique are compared to a similar processing scheme presented in previous works, giving rise to an improvement in the performance of the monitoring system.

8.
Appl Opt ; 46(16): 3215-20, 2007 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-17514278

RESUMEN

A new fiber sensor system designed for spectroscopic analysis and on-line quality assurance of arc-welding processes is presented here. Although several different approaches have been considered for the optical capture of plasma emission in arc-welding processes, they tend to be invasive and make use of optical devices such as collimators or photodiodes. The solution proposed here is based on the arrangement of an optical fiber, which is used at the same time as the optical capturing device and also to deliver the optical information to a spectrometer, embedded within an arc-welding torch. It will be demonstrated that, by using the shielding gas as a protection for the fiber end, the plasma light emission is efficiently collected, forming a sensor system completely transparent and noninvasive for the welding operator. The feasibility of the proposed sensor designed to be used as the input optics of a welding quality-assurance system based on plasma spectroscopy will be demonstrated by means of several welding tests.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA