Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
Más filtros

Tipo del documento
Intervalo de año de publicación
1.
Anesthesiology ; 140(4): 752-764, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38207290

RESUMEN

BACKGROUND: Lower fractional inspired oxygen tension (Fio2) during general anesthesia can reduce lung atelectasis. The objectives are to evaluate the effect of two Fio2 (0.4 and 1) during low positive end-expiratory pressure (PEEP) ventilation over lung perfusion distribution, volume, and regional ventilation. These variables were evaluated at two PEEP levels and unilateral lung atelectasis. METHODS: In this exploratory study, 10 healthy female piglets (32.3 ± 3.4 kg) underwent mechanical ventilation in two atelectasis models: (1) bilateral gravitational atelectasis (n = 6), induced by changes in PEEP and Fio2 in three combinations: high PEEP with low Fio2 (Fio2 = 0.4), zero PEEP (PEEP0) with low Fio2 (Fio2 = 0.4), and PEEP0 with high Fio2 (Fio2 = 1); and (2) unilateral atelectasis (n = 6), induced by left bronchial occlusion, with the left lung aerated (Fio2 = 0.21) and low aerated (Fio2 = 1; n = 5 for this step). Measurements were conducted after 10 min in each step, encompassing assessment of respiratory mechanics, oxygenation, and hemodynamics; lung ventilation and perfusion by electrical impedance tomography; and lung aeration and perfusion by computed tomography. RESULTS: During bilateral gravitational atelectasis, PEEP reduction increased atelectasis in dorsal regions, decreased respiratory compliance, and distributed lung ventilation to ventral regions with a parallel shift of perfusion to the same areas. With PEEP0, there were no differences between low and high Fio2 in respiratory compliance (23.9 ± 6.5 ml/cm H2O vs. 21.9 ± 5.0; P = 0.441), regional ventilation, and regional perfusion, despite higher lung collapse (18.6 ± 7.6% vs. 32.7 ± 14.5%; P = 0.045) with high Fio2. During unilateral lung atelectasis, the deaerated lung had a lower shunt (19.3 ± 3.6% vs. 25.3 ± 5.5%; P = 0.045) and lower computed tomography perfusion to the left lung (8.8 ± 1.8% vs. 23.8 ± 7.1%; P = 0.007). CONCLUSIONS: PEEP0 with low Fio2, compared with high Fio2, did not produce significant changes in respiratory system compliance, regional lung ventilation, and perfusion despite significantly lower lung collapse. After left bronchial occlusion, the shrinkage of the parenchyma with Fio2 = 1 enhanced hypoxic pulmonary vasoconstriction, reducing intrapulmonary shunt and perfusion of the nonventilated areas.


Asunto(s)
Atelectasia Pulmonar , Respiración Artificial , Animales , Femenino , Porcinos , Respiración Artificial/métodos , Pulmón/diagnóstico por imagen , Mediciones del Volumen Pulmonar , Atelectasia Pulmonar/diagnóstico por imagen , Atelectasia Pulmonar/terapia , Perfusión , Oxígeno
2.
Nitric Oxide ; 136-137: 1-7, 2023 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-37172929

RESUMEN

BACKGROUND: Impairment of ventilation and perfusion (V/Q) matching is a common mechanism leading to hypoxemia in patients with acute respiratory failure requiring intensive care unit (ICU) admission. While ventilation has been thoroughly investigated, little progress has been made to monitor pulmonary perfusion at the bedside and treat impaired blood distribution. The study aimed to assess real-time changes in regional pulmonary perfusion in response to a therapeutic intervention. METHODS: Single-center prospective study that enrolled adult patients with ARDS caused by SARS-Cov-2 who were sedated, paralyzed, and mechanically ventilated. The distribution of pulmonary perfusion was assessed through electrical impedance tomography (EIT) after the injection of a 10-ml bolus of hypertonic saline. The therapeutic intervention consisted in the administration of inhaled nitric oxide (iNO), as rescue therapy for refractory hypoxemia. Each patient underwent two 15-min steps at 0 and 20 ppm iNO, respectively. At each step, respiratory, gas exchange, and hemodynamic parameters were recorded, and V/Q distribution was measured, with unchanged ventilatory settings. RESULTS: Ten 65 [56-75] years old patients with moderate (40%) and severe (60%) ARDS were studied 10 [4-20] days after intubation. Gas exchange improved at 20 ppm iNO (PaO2/FiO2 from 86 ± 16 to 110 ± 30 mmHg, p = 0.001; venous admixture from 51 ± 8 to 45 ± 7%, p = 0.0045; dead space from 29 ± 8 to 25 ± 6%, p = 0.008). The respiratory system's elastic properties and ventilation distribution were unaltered by iNO. Hemodynamics did not change after gas initiation (cardiac output 7.6 ± 1.9 vs. 7.7 ± 1.9 L/min, p = 0.66). The EIT pixel perfusion maps showed a variety of patterns of changes in pulmonary blood flow, whose increase positively correlated with PaO2/FiO2 increase (R2 = 0.50, p = 0.049). CONCLUSIONS: The assessment of lung perfusion is feasible at the bedside and blood distribution can be modulated with effects that are visualized in vivo. These findings might lay the foundations for testing new therapies aimed at optimizing the regional perfusion in the lungs.


Asunto(s)
COVID-19 , Síndrome de Dificultad Respiratoria , Insuficiencia Respiratoria , Adulto , Humanos , Persona de Mediana Edad , Anciano , Circulación Pulmonar , Estudios Prospectivos , Intercambio Gaseoso Pulmonar , COVID-19/complicaciones , SARS-CoV-2 , Síndrome de Dificultad Respiratoria/tratamiento farmacológico , Síndrome de Dificultad Respiratoria/etiología , Óxido Nítrico , Hipoxia , Insuficiencia Respiratoria/tratamiento farmacológico , Administración por Inhalación
3.
Anesthesiology ; 139(6): 815-826, 2023 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-37566686

RESUMEN

BACKGROUND: Bedside electrical impedance tomography could be useful to visualize evolving pulmonary perfusion distributions when acute respiratory distress syndrome worsens or in response to ventilatory and positional therapies. In experimental acute respiratory distress syndrome, this study evaluated the agreement of electrical impedance tomography and dynamic contrast-enhanced computed tomography perfusion distributions at two injury time points and in response to increased positive end-expiratory pressure (PEEP) and prone position. METHODS: Eleven mechanically ventilated (VT 8 ml · kg-1) Yorkshire pigs (five male, six female) received bronchial hydrochloric acid (3.5 ml · kg-1) to invoke lung injury. Electrical impedance tomography and computed tomography perfusion images were obtained at 2 h (early injury) and 24 h (late injury) after injury in supine position with PEEP 5 and 10 cm H2O. In eight animals, electrical impedance tomography and computed tomography perfusion imaging were also conducted in the prone position. Electrical impedance tomography perfusion (QEIT) and computed tomography perfusion (QCT) values (as percentages of image total) were compared in eight vertical regions across injury stages, levels of PEEP, and body positions using mixed-effects linear regression. The primary outcome was agreement between QEIT and QCT, defined using limits of agreement and Pearson correlation coefficient. RESULTS: Pao2/Fio2 decreased over the course of the experiment (healthy to early injury, -253 [95% CI, -317 to -189]; early to late injury, -88 [95% CI, -151 to -24]). The limits of agreement between QEIT and QCT were -4.66% and 4.73% for the middle 50% quantile of average regional perfusion, and the correlation coefficient was 0.88 (95% CI, 0.86 to 0.90]; P < 0.001). Electrical impedance tomography and computed tomography showed similar perfusion redistributions over injury stages and in response to increased PEEP. QEIT redistributions after positional therapy underestimated QCT in ventral regions and overestimated QCT in dorsal regions. CONCLUSIONS: Electrical impedance tomography closely approximated computed tomography perfusion measures in experimental acute respiratory distress syndrome, in the supine position, over injury progression and with increased PEEP. Further validation is needed to determine the accuracy of electrical impedance tomography in measuring perfusion redistributions after positional changes.


Asunto(s)
Síndrome de Dificultad Respiratoria , Tomografía Computarizada por Rayos X , Masculino , Femenino , Porcinos , Animales , Impedancia Eléctrica , Síndrome de Dificultad Respiratoria/terapia , Pulmón , Perfusión , Tomografía/métodos
4.
Crit Care ; 27(1): 457, 2023 11 24.
Artículo en Inglés | MEDLINE | ID: mdl-38001485

RESUMEN

BACKGROUND: In the acute distress respiratory syndrome (ARDS), specific lung regions can be exposed to excessive strain due to heterogeneous disease, gravity-dependent lung collapse and injurious mechanical ventilation. Computed tomography (CT) is the gold standard for regional strain assessment. An alternative tool could be the electrical impedance tomography (EIT). We aimed to determine whether EIT-based methods can predict the dynamic relative regional strain (DRRS) between two levels of end-expiratory pressure (PEEP) in gravity-non-dependent and dependent lung regions. METHODS: Fourteen ARDS patients underwent CT and EIT acquisitions (at end-inspiratory and end-expiratory) at two levels of PEEP: a low-PEEP based on ARDS-net strategy and a high-PEEP titrated according to EIT. Three EIT-based methods for DRRS were compared to relative CT-based strain: (1) the change of the ratio between EIT ventilation and end-expiratory lung impedance in arbitrary units ([ΔZAU low-PEEP/EELIAU low-PEEP]/[ΔZAU high-PEEP/EELIAU high-PEEP]), (2) the change of ΔZ/EELI ratio calibrated to mL ([ΔZml low-PEEP/EELIml low-PEEP]/[ΔZml high-PEEP/EELIml high-PEEP]) using CT data, and (3) the relative change of ∆ZAU (∆ZAU low-PEEP/∆ZAU high-PEEP). We performed linear regressions analysis and calculated bias and limits of agreement to assess the performance of DRRS by EIT in comparison with CT. RESULTS: The DRRS assessed by (ΔZml low-PEEP/EELIml low-PEEP)/(ΔZml high-PEEP/EELIml high-PEEP) and ∆ZAU low-PEEP/∆ZAU high-PEEP showed good relationship and agreement with the CT method (R2 of 0.9050 and 0.8679, respectively, in non-dependent region; R2 of 0.8373 and 0.6588, respectively, in dependent region; biases ranging from - 0.11 to 0.51 and limits of agreement ranging from - 0.73 to 1.16 for both methods and lung regions). Conversely, DRRS based on EELIAU ([ΔZAU low-PEEP/EELIAU low-PEEP]/[ΔZAU high-PEEP/EELIAU high-PEEP]) exhibited a weak negative relationship and poor agreement with the CT method for both non-dependent and dependent regions (R2 ~ 0.3; bias of 3.11 and 2.08, and limits of agreement of - 2.13 to 8.34 and from - 1.49 to 5.64, respectively). CONCLUSION: Changes in DRRS during a PEEP trial in ARDS patients could be monitored using EIT, based on changes in ΔZmL/EELIml and ∆ZAU. The relative change ∆ZAU offers the advantage of not requiring CT data for calibration.


Asunto(s)
Respiración con Presión Positiva , Síndrome de Dificultad Respiratoria , Humanos , Impedancia Eléctrica , Respiración con Presión Positiva/métodos , Pulmón/diagnóstico por imagen , Tomografía Computarizada por Rayos X/métodos , Síndrome de Dificultad Respiratoria/diagnóstico por imagen , Tomografía/métodos
5.
Crit Care ; 27(1): 128, 2023 03 30.
Artículo en Inglés | MEDLINE | ID: mdl-36998022

RESUMEN

BACKGROUND: Patient-ventilator asynchronies are usually detected by visual inspection of ventilator waveforms but with low sensitivity, even when performed by experts in the field. Recently, estimation of the inspiratory muscle pressure (Pmus) waveforms through artificial intelligence algorithm has been proposed (Magnamed®, São Paulo, Brazil). We hypothesized that the display of these waveforms could help healthcare providers identify patient-ventilator asynchronies. METHODS: A prospective single-center randomized study with parallel assignment was conducted to assess whether the display of the estimated Pmus waveform would improve the correct identification of asynchronies in simulated clinical scenarios. The primary outcome was the mean asynchrony detection rate (sensitivity). Physicians and respiratory therapists who work in intensive care units were randomized to control or intervention group. In both groups, participants analyzed pressure and flow waveforms of 49 different scenarios elaborated using the ASL-5000 lung simulator. In the intervention group the estimated Pmus waveform was displayed in addition to pressure and flow waveforms. RESULTS: A total of 98 participants were included, 49 per group. The sensitivity per participant in identifying asynchronies was significantly higher in the Pmus group (65.8 ± 16.2 vs. 52.94 ± 8.42, p < 0.001). This effect remained when stratifying asynchronies by type. CONCLUSIONS: We showed that the display of the Pmus waveform improved the ability of healthcare professionals to recognize patient-ventilator asynchronies by visual inspection of ventilator tracings. These findings require clinical validation. TRIAL REGISTRATION: ClinicalTrials.gov: NTC05144607. Retrospectively registered 3 December 2021.


Asunto(s)
Inteligencia Artificial , Respiración Artificial , Humanos , Brasil , Atención a la Salud , Personal de Salud , Músculos , Estudios Prospectivos , Ventiladores Mecánicos
6.
Anesthesiology ; 136(5): 763-778, 2022 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-35348581

RESUMEN

BACKGROUND: Strong spontaneous inspiratory efforts can be difficult to control and prohibit protective mechanical ventilation. Instead of using deep sedation and neuromuscular blockade, the authors hypothesized that perineural administration of lidocaine around the phrenic nerve would reduce tidal volume (VT) and peak transpulmonary pressure in spontaneously breathing patients with acute respiratory distress syndrome. METHODS: An established animal model of acute respiratory distress syndrome with six female pigs was used in a proof-of-concept study. The authors then evaluated this technique in nine mechanically ventilated patients under pressure support exhibiting driving pressure greater than 15 cm H2O or VT greater than 10 ml/kg of predicted body weight. Esophageal and transpulmonary pressures, electrical activity of the diaphragm, and electrical impedance tomography were measured in pigs and patients. Ultrasound imaging and a nerve stimulator were used to identify the phrenic nerve, and perineural lidocaine was administered sequentially around the left and right phrenic nerves. RESULTS: Results are presented as median [interquartile range, 25th to 75th percentiles]. In pigs, VT decreased from 7.4 ml/kg [7.2 to 8.4] to 5.9 ml/kg [5.5 to 6.6] (P < 0.001), as did peak transpulmonary pressure (25.8 cm H2O [20.2 to 27.2] to 17.7 cm H2O [13.8 to 18.8]; P < 0.001) and driving pressure (28.7 cm H2O [20.4 to 30.8] to 19.4 cm H2O [15.2 to 22.9]; P < 0.001). Ventilation in the most dependent part decreased from 29.3% [26.4 to 29.5] to 20.1% [15.3 to 20.8] (P < 0.001). In patients, VT decreased (8.2 ml/ kg [7.9 to 11.1] to 6.0 ml/ kg [5.7 to 6.7]; P < 0.001), as did driving pressure (24.7 cm H2O [20.4 to 34.5] to 18.4 cm H2O [16.8 to 20.7]; P < 0.001). Esophageal pressure, peak transpulmonary pressure, and electrical activity of the diaphragm also decreased. Dependent ventilation only slightly decreased from 11.5% [8.5 to 12.6] to 7.9% [5.3 to 8.6] (P = 0.005). Respiratory rate did not vary. Variables recovered 1 to 12.7 h [6.7 to 13.7] after phrenic nerve block. CONCLUSIONS: Phrenic nerve block is feasible, lasts around 12 h, and reduces VT and driving pressure without changing respiratory rate in patients under assisted ventilation.


Asunto(s)
Lesión Pulmonar Aguda , Síndrome de Dificultad Respiratoria , Animales , Enfermedad Crítica , Modelos Animales de Enfermedad , Femenino , Humanos , Lidocaína , Nervio Frénico , Respiración Artificial/métodos , Síndrome de Dificultad Respiratoria/terapia , Mecánica Respiratoria/fisiología , Porcinos , Volumen de Ventilación Pulmonar/fisiología
7.
Am J Respir Crit Care Med ; 203(5): 575-584, 2021 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-32876469

RESUMEN

Rationale: Obesity is characterized by elevated pleural pressure (Ppl) and worsening atelectasis during mechanical ventilation in patients with acute respiratory distress syndrome (ARDS).Objectives: To determine the effects of a lung recruitment maneuver (LRM) in the presence of elevated Ppl on hemodynamics, left and right ventricular pressure, and pulmonary vascular resistance. We hypothesized that elevated Ppl protects the cardiovascular system against high airway pressure and prevents lung overdistension.Methods: First, an interventional crossover trial in adult subjects with ARDS and a body mass index ≥ 35 kg/m2 (n = 21) was performed to explore the hemodynamic consequences of the LRM. Second, cardiovascular function was studied during low and high positive end-expiratory pressure (PEEP) in a model of swine with ARDS and high Ppl (n = 9) versus healthy swine with normal Ppl (n = 6).Measurements and Main Results: Subjects with ARDS and obesity (body mass index = 57 ± 12 kg/m2) after LRM required an increase in PEEP of 8 (95% confidence interval [95% CI], 7-10) cm H2O above traditional ARDS Network settings to improve lung function, oxygenation and [Formula: see text]/[Formula: see text] matching, without impairment of hemodynamics or right heart function. ARDS swine with high Ppl demonstrated unchanged transmural left ventricular pressure and systemic blood pressure after the LRM protocol. Pulmonary arterial hypertension decreased (8 [95% CI, 13-4] mm Hg), as did vascular resistance (1.5 [95% CI, 2.2-0.9] Wood units) and transmural right ventricular pressure (10 [95% CI, 15-6] mm Hg) during exhalation. LRM and PEEP decreased pulmonary vascular resistance and normalized the [Formula: see text]/[Formula: see text] ratio.Conclusions: High airway pressure is required to recruit lung atelectasis in patients with ARDS and class III obesity but causes minimal overdistension. In addition, patients with ARDS and class III obesity hemodynamically tolerate LRM with high airway pressure.Clinical trial registered with www.clinicaltrials.gov (NCT02503241).


Asunto(s)
Atelectasia Pulmonar , Síndrome de Dificultad Respiratoria , Choque , Animales , Hemodinámica/fisiología , Humanos , Obesidad/complicaciones , Respiración con Presión Positiva/métodos , Síndrome de Dificultad Respiratoria/terapia , Porcinos
8.
Am J Respir Crit Care Med ; 204(3): 303-311, 2021 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-33784486

RESUMEN

Rationale: Mortality in acute respiratory distress syndrome (ARDS) has decreased after the adoption of lung-protective strategies. Lower Vt, lower driving pressure (ΔP), lower respiratory rates (RR), and higher end-expiratory pressure have all been suggested as key components of lung protection strategies. A unifying theoretical explanation has been proposed that attributes lung injury to the energy transfer rate (mechanical power) from the ventilator to the patient, calculated from a combination of several ventilator variables.Objectives: To assess the impact of mechanical power on mortality in patients with ARDS as compared with that of primary ventilator variables such as the ΔP, Vt, and RR.Methods: We obtained data on ventilatory variables and mechanical power from a pooled database of patients with ARDS who had participated in six randomized clinical trials of protective mechanical ventilation and one large observational cohort of patients with ARDS. The primary outcome was mortality at 28 days or 60 days.Measurements and Main Results: We included 4,549 patients (38% women; mean age, 55 ± 23 yr). The average mechanical power was 0.32 ± 0.14 J · min-1 · kg-1 of predicted body weight, the ΔP was 15.0 ± 5.8 cm H2O, and the RR was 25.7 ± 7.4 breaths/min. The driving pressure, RR, and mechanical power were significant predictors of mortality in adjusted analyses. The impact of the ΔP on mortality was four times as large as that of the RR.Conclusions: Mechanical power was associated with mortality during controlled mechanical ventilation in ARDS, but a simpler model using only the ΔP and RR was equivalent.


Asunto(s)
Mortalidad , Respiración Artificial/métodos , Síndrome de Dificultad Respiratoria/terapia , Adulto , Anciano , Transferencia de Energía , Femenino , Humanos , Masculino , Persona de Mediana Edad , Presión , Frecuencia Respiratoria , Lesión Pulmonar Inducida por Ventilación Mecánica
9.
Crit Care Med ; 49(10): e1015-e1024, 2021 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-33938714

RESUMEN

OBJECTIVES: It is not known how lung injury progression during mechanical ventilation modifies pulmonary responses to prone positioning. We compared the effects of prone positioning on regional lung aeration in late versus early stages of lung injury. DESIGN: Prospective, longitudinal imaging study. SETTING: Research imaging facility at The University of Pennsylvania (Philadelphia, PA) and Medical and Surgical ICUs at Massachusetts General Hospital (Boston, MA). SUBJECTS: Anesthetized swine and patients with acute respiratory distress syndrome (acute respiratory distress syndrome). INTERVENTIONS: Lung injury was induced by bronchial hydrochloric acid (3.5 mL/kg) in 10 ventilated Yorkshire pigs and worsened by supine nonprotective ventilation for 24 hours. Whole-lung CT was performed 2 hours after hydrochloric acid (Day 1) in both prone and supine positions and repeated at 24 hours (Day 2). Prone and supine images were registered (superimposed) in pairs to measure the effects of positioning on the aeration of each tissue unit. Two patients with early acute respiratory distress syndrome were compared with two patients with late acute respiratory distress syndrome, using electrical impedance tomography to measure the effects of body position on regional lung mechanics. MEASUREMENTS AND MAIN RESULTS: Gas exchange and respiratory mechanics worsened over 24 hours, indicating lung injury progression. On Day 1, prone positioning reinflated 18.9% ± 5.2% of lung mass in the posterior lung regions. On Day 2, position-associated dorsal reinflation was reduced to 7.3% ± 1.5% (p < 0.05 vs Day 1). Prone positioning decreased aeration in the anterior lungs on both days. Although prone positioning improved posterior lung compliance in the early acute respiratory distress syndrome patients, it had no effect in late acute respiratory distress syndrome subjects. CONCLUSIONS: The effects of prone positioning on lung aeration may depend on the stage of lung injury and duration of prior ventilation; this may limit the clinical efficacy of this treatment if applied late.


Asunto(s)
Lesión Pulmonar/complicaciones , Posición Prona/fisiología , Adulto , Anciano , Boston , Femenino , Humanos , Estudios Longitudinales , Lesión Pulmonar/diagnóstico por imagen , Lesión Pulmonar/fisiopatología , Masculino , Persona de Mediana Edad , Pennsylvania , Respiración con Presión Positiva/métodos , Estudios Prospectivos , Resultado del Tratamiento
10.
Nitric Oxide ; 116: 7-13, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-34400339

RESUMEN

BACKGROUND: Inhaled nitric oxide (NO) is a selective pulmonary vasodilator. In-vitro studies report that NO donors can inhibit replication of SARS-CoV-2. This multicenter study evaluated the feasibility and effects of high-dose inhaled NO in non-intubated spontaneously breathing patients with Coronavirus disease-2019 (COVID-19). METHODS: This is an interventional study to determine whether NO at 160 parts-per-million (ppm) inhaled for 30 min twice daily might be beneficial and safe in non-intubated COVID-19 patients. RESULTS: Twenty-nine COVID-19 patients received a total of 217 intermittent inhaled NO treatments for 30 min at 160 ppm between March and June 2020. Breathing NO acutely decreased the respiratory rate of tachypneic patients and improved oxygenation in hypoxemic patients. The maximum level of nitrogen dioxide delivered was 1.5 ppm. The maximum level of methemoglobin (MetHb) during the treatments was 4.7%. MetHb decreased in all patients 5 min after discontinuing NO administration. No adverse events during treatment, such as hypoxemia, hypotension, or acute kidney injury during hospitalization occurred. In our NO treated patients, one patient of 29 underwent intubation and mechanical ventilation, and none died. The median hospital length of stay was 6 days [interquartile range 4-8]. No discharged patients required hospital readmission nor developed COVID-19 related long-term sequelae within 28 days of follow-up. CONCLUSIONS: In spontaneous breathing patients with COVID-19, the administration of inhaled NO at 160 ppm for 30 min twice daily promptly improved the respiratory rate of tachypneic patients and systemic oxygenation of hypoxemic patients. No adverse events were observed. None of the subjects was readmitted or had long-term COVID-19 sequelae.


Asunto(s)
Tratamiento Farmacológico de COVID-19 , Hospitalización , Óxido Nítrico/administración & dosificación , Neumonía Viral/tratamiento farmacológico , Respiración/efectos de los fármacos , Administración por Inhalación , COVID-19/complicaciones , COVID-19/virología , Relación Dosis-Respuesta a Droga , Humanos , Óxido Nítrico/farmacología , Óxido Nítrico/uso terapéutico , Neumonía Viral/complicaciones
11.
Acta Anaesthesiol Scand ; 65(2): 228-235, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33037607

RESUMEN

RATIONALE: Cyclic strain may be a determinant of ventilator-induced lung injury. The standard for strain assessment is the computed tomography (CT), which does not allow continuous monitoring and exposes to radiation. Electrical impedance tomography (EIT) is able to monitor changes in regional lung ventilation. In addition, there is a correlation between mechanical deformation of materials and detectable changes in its electrical impedance, making EIT a potential surrogate for cyclic lung strain measured by CT (StrainCT ). OBJECTIVES: To compare the global StrainCT with the change in electrical impedance (ΔZ). METHODS: Acute respiratory distress syndrome patients under mechanical ventilation (VT 6 mL/kg ideal body weight with positive end-expiratory pressure 5 [PEEP 5] and best PEEP according to EIT) underwent whole-lung CT at end-inspiration and end-expiration. Biomechanical analysis was used to construct 3D maps and determine StrainCT at different levels of PEEP. CT and EIT acquisitions were performed simultaneously. Multilevel analysis was employed to determine the causal association between StrainCT and ΔZ. Linear regression models were used to predict the change in lung StrainCT between different PEEP levels based on the change in ΔZ. MAIN RESULTS: StrainCT was positively and independently associated with ΔZ at global level (P < .01). Furthermore, the change in StrainCT (between PEEP 5 and Best PEEP) was accurately predicted by the change in ΔZ (R2 0.855, P < .001 at global level) with a high agreement between predicted and measured StrainCT . CONCLUSIONS: The change in electrical impedance may provide a noninvasive assessment of global cyclic strain, without radiation at bedside.


Asunto(s)
Pulmón , Tomografía , Impedancia Eléctrica , Humanos , Pulmón/diagnóstico por imagen , Respiración con Presión Positiva , Tomografía Computarizada por Rayos X
12.
Nitric Oxide ; 104-105: 29-35, 2020 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-32835810

RESUMEN

BACKGROUND: There is an increasing interest in safely delivering high dose of inhaled nitric oxide (NO) as an antimicrobial and antiviral therapeutics for spontaneously breathing patients. A novel NO delivery system is described. METHODS: We developed a gas delivery system that utilizes standard respiratory circuit connectors, a reservoir bag, and a scavenging chamber containing calcium hydroxide. The performance of the system was tested using a mechanical lung, assessing the NO concentration delivered at varying inspiratory flows. Safety was assessed in vitro and in vivo by measuring nitrogen dioxide (NO2) levels in the delivered NO gas. Lastly, we measured the inspired and expired NO and NO2 of this system in 5 healthy subjects during a 15-min administration of high dose NO (160 parts-per-million, ppm) using our delivery system. RESULTS: The system demonstrated stable delivery of prescribed NO levels at various inspiratory flow rates (0-50 L/min). The reservoir bag and a high flow of entering air minimized the oscillation of NO concentrations during inspiration on average 4.6 ppm for each 10 L/min increment in lung inspiratory flow. The calcium hydroxide scavenger reduced the inhaled NO2 concentration on average 0.9 ppm (95% CI -1.58, -0.22; p = .01). We performed 49 NO administrations of 160 ppm in 5 subjects. The average concentration of inspired NO was 164.8±10.74 ppm, with inspired NO2 levels of 0.7±0.13 ppm. The subjects did not experience any adverse events; transcutaneous methemoglobin concentrations increased from 1.05±0.58 to 2.26±0.47%. CONCLUSIONS: The system we developed to administer high-dose NO for inhalation is easy to build, reliable, was well tolerated in healthy subjects.


Asunto(s)
Sistemas de Liberación de Medicamentos/instrumentación , Sistemas de Liberación de Medicamentos/métodos , Óxido Nítrico/administración & dosificación , Administración por Inhalación , Adulto , Femenino , Humanos , Masculino , Respiración
14.
Anesthesiology ; 130(5): 791-803, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30844949

RESUMEN

BACKGROUND: Obese patients are characterized by normal chest-wall elastance and high pleural pressure and have been excluded from trials assessing best strategies to set positive end-expiratory pressure (PEEP) in acute respiratory distress syndrome (ARDS). The authors hypothesized that severely obese patients with ARDS present with a high degree of lung collapse, reversible by titrated PEEP preceded by a lung recruitment maneuver. METHODS: Severely obese ARDS patients were enrolled in a physiologic crossover study evaluating the effects of three PEEP titration strategies applied in the following order: (1) PEEPARDSNET: the low PEEP/FIO2 ARDSnet table; (2) PEEPINCREMENTAL: PEEP levels set to determine a positive end-expiratory transpulmonary pressure; and (3) PEEPDECREMENTAL: PEEP levels set to determine the lowest respiratory system elastance during a decremental PEEP trial following a recruitment maneuver on respiratory mechanics, regional lung collapse, and overdistension according to electrical impedance tomography and gas exchange. RESULTS: Fourteen patients underwent the study procedures. At PEEPARDSNET (13 ± 1 cm H2O) end-expiratory transpulmonary pressure was negative (-5 ± 5 cm H2O), lung elastance was 27 ± 12 cm H2O/L, and PaO2/FIO2 was 194 ± 111 mmHg. Compared to PEEPARDSNET, at PEEPINCREMENTAL level (22 ± 3 cm H2O) lung volume increased (977 ± 708 ml), lung elastance decreased (23 ± 7 cm H2O/l), lung collapse decreased (18 ± 10%), and ventilation homogeneity increased thus rising oxygenation (251 ± 105 mmHg), despite higher overdistension levels (16 ± 12%), all values P < 0.05 versus PEEPARDSnet. Setting PEEP according to a PEEPDECREMENTAL trial after a recruitment maneuver (21 ± 4 cm H2O, P = 0.99 vs. PEEPINCREMENTAL) further lowered lung elastance (19 ± 6 cm H2O/l) and increased oxygenation (329 ± 82 mmHg) while reducing lung collapse (9 ± 2%) and overdistension (11 ± 2%), all values P < 0.05 versus PEEPARDSnet and PEEPINCREMENTAL. All patients were maintained on titrated PEEP levels up to 24 h without hemodynamic or ventilation related complications. CONCLUSIONS: Among the PEEP titration strategies tested, setting PEEP according to a PEEPDECREMENTAL trial preceded by a recruitment maneuver obtained the best lung function by decreasing lung overdistension and collapse, restoring lung elastance, and oxygenation suggesting lung tissue recruitment.


Asunto(s)
Obesidad/fisiopatología , Respiración con Presión Positiva/métodos , Síndrome de Dificultad Respiratoria/terapia , Adulto , Anciano , Estudios Cruzados , Femenino , Humanos , Masculino , Persona de Mediana Edad , Mecánica Respiratoria/fisiología
15.
Am J Respir Crit Care Med ; 197(8): 1018-1026, 2018 04 15.
Artículo en Inglés | MEDLINE | ID: mdl-29323931

RESUMEN

RATIONALE: Esophageal manometry is the clinically available method to estimate pleural pressure, thus enabling calculation of transpulmonary pressure (Pl). However, many concerns make it uncertain in which lung region esophageal manometry reflects local Pl. OBJECTIVES: To determine the accuracy of esophageal pressure (Pes) and in which regions esophageal manometry reflects pleural pressure (Ppl) and Pl; to assess whether lung stress in nondependent regions can be estimated at end-inspiration from Pl. METHODS: In lung-injured pigs (n = 6) and human cadavers (n = 3), Pes was measured across a range of positive end-expiratory pressure, together with directly measured Ppl in nondependent and dependent pleural regions. All measurements were obtained with minimal nonstressed volumes in the pleural sensors and esophageal balloons. Expiratory and inspiratory Pl was calculated by subtracting local Ppl or Pes from airway pressure; inspiratory Pl was also estimated by subtracting Ppl (calculated from chest wall and respiratory system elastance) from the airway plateau pressure. MEASUREMENTS AND MAIN RESULTS: In pigs and human cadavers, expiratory and inspiratory Pl using Pes closely reflected values in dependent to middle lung (adjacent to the esophagus). Inspiratory Pl estimated from elastance ratio reflected the directly measured nondependent values. CONCLUSIONS: These data support the use of esophageal manometry in acute respiratory distress syndrome. Assuming correct calibration, expiratory Pl derived from Pes reflects Pl in dependent to middle lung, where atelectasis usually predominates; inspiratory Pl estimated from elastance ratio may indicate the highest level of lung stress in nondependent "baby" lung, where it is vulnerable to ventilator-induced lung injury.


Asunto(s)
Esófago/fisiopatología , Manometría/métodos , Respiración con Presión Positiva/métodos , Respiración Artificial/métodos , Mecánica Respiratoria/fisiología , Lesión Pulmonar Inducida por Ventilación Mecánica/diagnóstico , Lesión Pulmonar Inducida por Ventilación Mecánica/fisiopatología , Animales , Cadáver , Humanos , Modelos Animales , Pruebas de Función Respiratoria , Porcinos
16.
Am J Respir Crit Care Med ; 197(10): 1285-1296, 2018 05 15.
Artículo en Inglés | MEDLINE | ID: mdl-29323536

RESUMEN

RATIONALE: In acute respiratory distress syndrome (ARDS), atelectatic solid-like lung tissue impairs transmission of negative swings in pleural pressure (Ppl) that result from diaphragmatic contraction. The localization of more negative Ppl proportionally increases dependent lung stretch by drawing gas either from other lung regions (e.g., nondependent lung [pendelluft]) or from the ventilator. Lowering the level of spontaneous effort and/or converting solid-like to fluid-like lung might render spontaneous effort noninjurious. OBJECTIVES: To determine whether spontaneous effort increases dependent lung injury, and whether such injury would be reduced by recruiting atelectatic solid-like lung with positive end-expiratory pressure (PEEP). METHODS: Established models of severe ARDS (rabbit, pig) were used. Regional histology (rabbit), inflammation (positron emission tomography; pig), regional inspiratory Ppl (intrabronchial balloon manometry), and stretch (electrical impedance tomography; pig) were measured. Respiratory drive was evaluated in 11 patients with ARDS. MEASUREMENTS AND MAIN RESULTS: Although injury during muscle paralysis was predominantly in nondependent and middle lung regions at low (vs. high) PEEP, strong inspiratory effort increased injury (indicated by positron emission tomography and histology) in dependent lung. Stronger effort (vs. muscle paralysis) caused local overstretch and greater tidal recruitment in dependent lung, where more negative Ppl was localized and greater stretch was generated. In contrast, high PEEP minimized lung injury by more uniformly distributing negative Ppl, and lowering the magnitude of spontaneous effort (i.e., deflection in esophageal pressure observed in rabbits, pigs, and patients). CONCLUSIONS: Strong effort increased dependent lung injury, where higher local lung stress and stretch was generated; effort-dependent lung injury was minimized by high PEEP in severe ARDS, which may offset need for paralysis.


Asunto(s)
Pulmón/fisiopatología , Respiración con Presión Positiva/métodos , Respiración Artificial/efectos adversos , Respiración Artificial/métodos , Síndrome de Dificultad Respiratoria/complicaciones , Síndrome de Dificultad Respiratoria/terapia , Animales , Modelos Animales de Enfermedad , Conejos , Porcinos
17.
Anesthesiology ; 129(6): 1070-1081, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30260897

RESUMEN

WHAT WE ALREADY KNOW ABOUT THIS TOPIC: WHAT THIS ARTICLE TELLS US THAT IS NEW: BACKGROUND:: Intraoperative lung-protective ventilation has been recommended to reduce postoperative pulmonary complications after abdominal surgery. Although the protective role of a more physiologic tidal volume has been established, the added protection afforded by positive end-expiratory pressure (PEEP) remains uncertain. The authors hypothesized that a low fixed PEEP might not fit all patients and that an individually titrated PEEP during anesthesia might improve lung function during and after surgery. METHODS: Forty patients were studied in the operating room (20 laparoscopic and 20 open-abdominal). They underwent elective abdominal surgery and were randomized to institutional PEEP (4 cm H2O) or electrical impedance tomography-guided PEEP (applied after recruitment maneuvers and targeted at minimizing lung collapse and hyperdistension, simultaneously). Patients were extubated without changing selected PEEP or fractional inspired oxygen tension while under anesthesia and submitted to chest computed tomography after extubation. Our primary goal was to individually identify the electrical impedance tomography-guided PEEP value producing the best compromise of lung collapse and hyperdistention. RESULTS: Electrical impedance tomography-guided PEEP varied markedly across individuals (median, 12 cm H2O; range, 6 to 16 cm H2O; 95% CI, 10-14). Compared with PEEP of 4 cm H2O, patients randomized to the electrical impedance tomography-guided strategy had less postoperative atelectasis (6.2 ± 4.1 vs. 10.8 ± 7.1% of lung tissue mass; P = 0.017) and lower intraoperative driving pressures (mean values during surgery of 8.0 ± 1.7 vs. 11.6 ± 3.8 cm H2O; P < 0.001). The electrical impedance tomography-guided PEEP arm had higher intraoperative oxygenation (435 ± 62 vs. 266 ± 76 mmHg for laparoscopic group; P < 0.001), while presenting equivalent hemodynamics (mean arterial pressure during surgery of 80 ± 14 vs. 78 ± 15 mmHg; P = 0.821). CONCLUSIONS: PEEP requirements vary widely among patients receiving protective tidal volumes during anesthesia for abdominal surgery. Individualized PEEP settings could reduce postoperative atelectasis (measured by computed tomography) while improving intraoperative oxygenation and driving pressures, causing minimum side effects.


Asunto(s)
Cuidados Intraoperatorios/métodos , Respiración con Presión Positiva/métodos , Complicaciones Posoperatorias/prevención & control , Medicina de Precisión/métodos , Atelectasia Pulmonar/prevención & control , Respiración Artificial/métodos , Abdomen/cirugía , Adulto , Anciano , Anestesia Intravenosa , Procedimientos Quirúrgicos Electivos , Femenino , Humanos , Laparoscopía , Tiempo de Internación , Masculino , Persona de Mediana Edad , Consumo de Oxígeno , Respiración con Presión Positiva/efectos adversos , Atelectasia Pulmonar/epidemiología , Atelectasia Pulmonar/etiología , Respiración Artificial/efectos adversos , Volumen de Ventilación Pulmonar , Tomografía
18.
Crit Care ; 22(1): 263, 2018 10 25.
Artículo en Inglés | MEDLINE | ID: mdl-30360753

RESUMEN

Acute respiratory distress syndrome (ARDS) is a clinical entity that acutely affects the lung parenchyma, and is characterized by diffuse alveolar damage and increased pulmonary vascular permeability. Currently, computed tomography (CT) is commonly used for classifying and prognosticating ARDS. However, performing this examination in critically ill patients is complex, due to the need to transfer these patients to the CT room. Fortunately, new technologies have been developed that allow the monitoring of patients at the bedside. Electrical impedance tomography (EIT) is a monitoring tool that allows one to evaluate at the bedside the distribution of pulmonary ventilation continuously, in real time, and which has proven to be useful in optimizing mechanical ventilation parameters in critically ill patients. Several clinical applications of EIT have been developed during the last years and the technique has been generating increasing interest among researchers. However, among clinicians, there is still a lack of knowledge regarding the technical principles of EIT and potential applications in ARDS patients. The aim of this review is to present the characteristics, technical concepts, and clinical applications of EIT, which may allow better monitoring of lung function during ARDS.


Asunto(s)
Impedancia Eléctrica/uso terapéutico , Síndrome de Dificultad Respiratoria/diagnóstico , Tomografía Computarizada por Rayos X/métodos , Humanos , Pulmón/anomalías , Pulmón/diagnóstico por imagen , Pulmón/fisiopatología , Respiración Artificial/métodos , Fenómenos Fisiológicos Respiratorios , Tomografía Computarizada por Rayos X/instrumentación
19.
Crit Care Med ; 45(8): 1374-1381, 2017 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-28708679

RESUMEN

OBJECTIVES: Atelectasis develops in critically ill obese patients when undergoing mechanical ventilation due to increased pleural pressure. The current study aimed to determine the relationship between transpulmonary pressure, lung mechanics, and lung morphology and to quantify the benefits of a decremental positive end-expiratory pressure trial preceded by a recruitment maneuver. DESIGN: Prospective, crossover, nonrandomized interventional study. SETTING: Medical and Surgical Intensive Care Units at Massachusetts General Hospital (Boston, MA) and University Animal Research Laboratory (São Paulo, Brazil). PATIENTS/SUBJECTS: Critically ill obese patients with acute respiratory failure and anesthetized swine. INTERVENTIONS: Clinical data from 16 mechanically ventilated critically ill obese patients were analyzed. An animal model of obesity with reversible atelectasis was developed by placing fluid filled bags on the abdomen to describe changes of lung mechanics, lung morphology, and pulmonary hemodynamics in 10 swine. MEASUREMENTS AND MAIN RESULTS: In obese patients (body mass index, 48 ± 11 kg/m), 21.7 ± 3.7 cm H2O of positive end-expiratory pressure resulted in the lowest elastance of the respiratory system (18.6 ± 6.1 cm H2O/L) after a recruitment maneuver and decremental positive end-expiratory pressure and corresponded to a positive (2.1 ± 2.2 cm H2O) end-expiratory transpulmonary pressure. Ventilation at lowest elastance positive end-expiratory pressure preceded by a recruitment maneuver restored end-expiratory lung volume (30.4 ± 9.1 mL/kg ideal body weight) and oxygenation (273.4 ± 72.1 mm Hg). In the swine model, lung collapse and intratidal recruitment/derecruitment occurred when the positive end-expiratory transpulmonary pressure decreased below 2-4 cm H2O. After the development of atelectasis, a decremental positive end-expiratory pressure trial preceded by lung recruitment identified the positive end-expiratory pressure level (17.4 ± 2.1 cm H2O) needed to restore poorly and nonaerated lung tissue, reestablishing lung elastance and oxygenation while avoiding increased pulmonary vascular resistance. CONCLUSIONS: In obesity, low-to-negative values of transpulmonary pressure predict lung collapse and intratidal recruitment/derecruitment. A decremental positive end-expiratory pressure trial preceded by a recruitment maneuver reverses atelectasis, improves lung mechanics, distribution of ventilation and oxygenation, and does not increase pulmonary vascular resistance.


Asunto(s)
Enfermedad Crítica , Pulmón/patología , Obesidad/fisiopatología , Atelectasia Pulmonar/fisiopatología , Respiración Artificial/efectos adversos , Animales , Modelos Animales de Enfermedad , Impedancia Eléctrica , Humanos , Unidades de Cuidados Intensivos , Pulmón/diagnóstico por imagen , Obesidad/terapia , Respiración de Presión Positiva Intrínseca , Estudios Prospectivos , Mecánica Respiratoria , Porcinos , Tomografía Computarizada por Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA