Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Retina ; 42(2): 357-368, 2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-34510129

RESUMEN

PURPOSE: To assess global, zonal, and local correlations between vessel density changes measured by optical coherence tomography angiography and retinal sensitivity measured by microperimetry across diabetic retinopathy severity. METHODS: Diabetic patients and nondiabetic controls underwent optical coherence tomography angiography imaging and microperimetry testing. Pearson's correlation was used to assess associations between average sensitivity and skeletonized vessel density (SVD) or foveal avascular zone area centrally. Linear mixed effects modeling was used to assess relationships between local SVD measurements and their spatially corresponding retinal sensitivity measurements. RESULTS: Thirty-nine eyes from 39 participants were imaged. In all slabs, there was a statistically significant positive correlation between retinal sensitivities and SVDs on both global and zonal scales. No statistically significant correlation was found between central retinal sensitivities and the foveal avascular zone areas. Assessment of 1,136 spatially paired retinal sensitivity and SVD measurements revealed a statistically significant local relationship; this seemed to be driven by eyes with proliferative diabetic retinopathy that had reduced retinal sensitivities. CONCLUSION: This study supports positive correlations between SVD and retinal sensitivity at global and zonal spatial scales in diabetic eyes. However, our analysis did not find evidence of statistically significant correlations between retinal sensitivity and SVD on a local scale until advanced diabetic retinopathy.


Asunto(s)
Retinopatía Diabética/fisiopatología , Retina/fisiología , Vasos Retinianos/fisiopatología , Campos Visuales/fisiología , Adulto , Anciano , Anciano de 80 o más Años , Angiografía por Tomografía Computarizada , Estudios Transversales , Retinopatía Diabética/diagnóstico por imagen , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Flujo Sanguíneo Regional/fisiología , Vasos Retinianos/diagnóstico por imagen , Tomografía de Coherencia Óptica , Agudeza Visual/fisiología , Pruebas del Campo Visual
2.
Retina ; 41(10): 2059-2065, 2021 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-33675334

RESUMEN

PURPOSE: To assess the full-thickness macular hole (FTMH) size using the choroidal hypertransmission signal on spectral-domain optical coherence tomography and to compare this method to the standard aperture measurement of the minimum aperture size at the level of the neurosensory retina. DESIGN: Cross-sectional study of retrospective data. METHODS: Eyes with FTMH imaged on spectral-domain optical coherence tomography were included. Two independent masked graders used the device's built-in caliper tool to measure the FTMH minimum aperture size at the level of the neurosensory retina and the size of the corresponding hypertransmission signal below the level of the retinal pigment epithelium/Bruch membrane complex. To assess the reproducibility of the hypertransmission measurement in tilted scans, two measurements were obtained and compared; the first was traced parallel to the retinal pigment epithelium (parallel hypertransmission), and the second was horizontal to the image frame (horizontal hypertransmission), both using Image J software. RESULTS: A total of 31 eyes were enrolled. The mean FTMH minimum aperture size was smaller compared with both the choroidal parallel hypertransmission and horizontal hypertransmission measurements (mean ± SD: 335.7 ± 139.5 µm, 376.7 ± 150.6 µm, 375.1 ± 150.0 µm, respectively. P < 0.001 for both comparisons). CONCLUSION: The proposed hypertransmission measurement is a feasible and reproducible alternative to assess FTMH size and could provide the basis for an automated FTMH measurement on cross-sectional spectral-domain optical coherence tomography scans, as presented in this study, or on the spectral-domain optical coherence tomography volumetric data set by using an en face projection.


Asunto(s)
Coroides/diagnóstico por imagen , Perforaciones de la Retina/diagnóstico por imagen , Tomografía de Coherencia Óptica , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Perforaciones de la Retina/patología , Epitelio Pigmentado de la Retina/diagnóstico por imagen , Estudios Retrospectivos , Agudeza Visual
3.
Clin Exp Ophthalmol ; 49(7): 714-723, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34189816

RESUMEN

BACKGROUND: To evaluate the changes in the mean macular intercapillary area (ICA) from sequential enface optical coherence tomography angiography (OCTA) images following intravitreal anti-vascular endothelial growth factor (VEGF) therapy in initially treatment-naïve eyes with diabetic macular oedema (DME). METHODS: In this multicentre retrospective study, 6 × 6 and 3 × 3 mm customised, total retinal projection enface OCTA images were collected and processed for quantitative assessment of ICA by a customised MATLAB software. Measurements were done in concentric regions centred on the fovea-with the exclusion of foveal avascular zone (FAZ)-in 0.5 mm diameter increments as well as within the intervening rings. RESULTS: In this study, 6 × 6 mm OCTA images from 46 eyes of 29 patients, and 3 × 3 mm OCTA images from 23 eyes of 15 patients were included. There was no significant change in mean ICA after treatment in either scan size or in any measurement regions (all p > 0.05). Multivariate analysis revealed that baseline BCVA was significantly correlated with the visual outcome (p = 0.039). Additionally, after correction for age, baseline central retinal thickness (CRT), baseline BCVA, and retinopathy severity, mean ICA in the 1.5 mm circle was found to be a significant predictor of post treatment CRT, (p = 0.006). CONCLUSIONS: Absence of significant change in mean ICA after a minimum of three intravitreal anti-VEGF injections, may indicate that, in the short term, anti-VEGF injections neither impair nor improve macular perfusion in DME. Baseline BCVA was found to be a robust predictor of functional outcome, while inner mean ICA was a significant predictor for macular thickness outcomes.


Asunto(s)
Diabetes Mellitus , Retinopatía Diabética , Edema Macular , Inhibidores de la Angiogénesis/uso terapéutico , Retinopatía Diabética/diagnóstico , Retinopatía Diabética/tratamiento farmacológico , Humanos , Inyecciones Intravítreas , Edema Macular/diagnóstico , Edema Macular/tratamiento farmacológico , Edema Macular/etiología , Ranibizumab/uso terapéutico , Estudios Retrospectivos , Tomografía de Coherencia Óptica , Factor A de Crecimiento Endotelial Vascular , Agudeza Visual
4.
Retina ; 40(3): 412-420, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-30576300

RESUMEN

PURPOSE: To combine advances in high-speed, wide-field optical coherence tomography angiography (OCTA) with image processing methods for semiautomatic quantitative analysis of capillary nonperfusion in patients with diabetic retinopathy (DR). METHODS: Sixty-eight diabetic patients (73 eyes), either without retinopathy or with different degrees of retinopathy, were prospectively recruited for volumetric swept-source OCTA imaging using 12 mm × 12 mm fields centered at the fovea. A custom, semiautomatic software algorithm was used to quantify areas of capillary nonperfusion. RESULTS: The mean percentage of nonperfused area was 0.1% (95% confidence interval: 0.0-0.4) in the eyes without DR; 2.1% (95% confidence interval: 1.2-3.7) in the nonproliferative DR eyes (mild, moderate, and severe), and 8.5% (95% confidence interval: 5.0-14.3) in the proliferative DR eyes. The percentage of nonperfused area increased in a statistically significant manner from eyes without DR, to eyes with nonproliferative DR, to eyes with proliferative DR. CONCLUSION: Capillary nonperfusion area in the posterior retina increases with increasing DR severity as measured by swept-source OCTA. Quantitative analysis of retinal nonperfusion on wide-field OCTA may be useful for early detection and monitoring of disease in patients with diabetes and DR.


Asunto(s)
Diabetes Mellitus Tipo 2/complicaciones , Retinopatía Diabética/diagnóstico , Angiografía con Fluoresceína/métodos , Flujo Sanguíneo Regional/fisiología , Vasos Retinianos/patología , Tomografía de Coherencia Óptica/métodos , Capilares/patología , Retinopatía Diabética/etiología , Retinopatía Diabética/fisiopatología , Femenino , Estudios de Seguimiento , Fondo de Ojo , Humanos , Masculino , Persona de Mediana Edad , Vasos Retinianos/fisiopatología , Estudios Retrospectivos
5.
Retina ; 40(3): 428-445, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31415449

RESUMEN

PURPOSE: To develop an optical coherence tomography angiography (OCTA)-based framework for quantitatively analyzing the spatial distribution of choriocapillaris (CC) impairment around choroidal neovascularization (CNV) secondary to age-related macular degeneration. METHODS: In a retrospective, cross-sectional study, 400-kHz swept-source OCTA images from 7 eyes of 6 patients with CNV secondary to age-related macular degeneration were quantitatively analyzed using custom software. A lesion-centered zonal OCTA analysis technique-which portioned the field-of-view into zones relative to CNV boundaries-was developed to quantify the spatial dependence of CC flow deficits. RESULTS: Quantitative, lesion-centered zonal analysis of CC OCTA images revealed highest flow-deficit percentages near CNV boundaries, decreasing in zones farther from the boundaries. Optical coherence tomography angiography using shorter (1.5 ms) interscan times revealed more severe flow deficits than OCTA using longer (3.0 ms) interscan times; however, spatial trends were similar for both interscan times. A detailed description of the OCTA processing steps and parameters was provided so as to elucidate their influence on quantitative measurements. CONCLUSION: Impairment of the CC, assessed by flow-deficit percentages, was most prominent closest to CNV boundaries. The lesion-centered zonal analysis technique enabled quantitative CC measurements relative to focal lesions. Understanding how processing steps, imaging/processing parameters, and artifacts can affect quantitative CC measurements is important for longitudinal, OCTA-based studies of disease progression, and treatment response.


Asunto(s)
Artefactos , Coroides/irrigación sanguínea , Neovascularización Coroidal/diagnóstico , Angiografía con Fluoresceína/métodos , Degeneración Macular/complicaciones , Vasos Retinianos/patología , Tomografía de Coherencia Óptica/métodos , Anciano , Anciano de 80 o más Años , Neovascularización Coroidal/etiología , Estudios Transversales , Femenino , Fondo de Ojo , Humanos , Degeneración Macular/diagnóstico , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
6.
Retina ; 37(1): 11-21, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-27557084

RESUMEN

PURPOSE: To investigate the utility of ultrahigh speed, swept source optical coherence tomography angiography in visualizing retinal microvascular and choriocapillaris (CC) changes in diabetic patients. METHODS: The study was prospective and cross-sectional. A 1,050 nm wavelength, 400 kHz A-scan rate swept source optical coherence tomography prototype was used to perform volumetric optical coherence tomography angiography of the retinal and CC vasculatures in diabetic patients and normal subjects. Sixty-three eyes from 32 normal subjects, 9 eyes from 7 patients with proliferative diabetic retinopathy, 29 eyes from 16 patients with nonproliferative diabetic retinopathy, and 51 eyes from 28 diabetic patients without retinopathy were imaged. RESULTS: Retinal and CC microvascular abnormalities were observed in all stages of diabetic retinopathy. In nonproliferative diabetic retinopathy and proliferative diabetic retinopathy, optical coherence tomography angiography visualized a variety of vascular abnormalities, including clustered capillaries, dilated capillary segments, tortuous capillaries, regions of capillary dropout, reduced capillary density, abnormal capillary loops, and foveal avascular zone enlargement. In proliferative diabetic retinopathy, retinal neovascularization above the inner limiting membrane was visualized. Regions of CC flow impairment in patients with proliferative diabetic retinopathy and nonproliferative diabetic retinopathy were also observed. In 18 of the 51 of eyes from diabetic patients without retinopathy, retinal mircrovascular abnormalities were observed and CC flow impairment was found in 24 of the 51 diabetic eyes without retinopathy. CONCLUSION: The ability of optical coherence tomography angiography to visualize retinal and CC microvascular abnormalities suggests it may be a useful tool for understanding pathogenesis, evaluating treatment response, and earlier detection of vascular abnormalities in patients with diabetes.


Asunto(s)
Capilares , Coroides/irrigación sanguínea , Retinopatía Diabética/fisiopatología , Tomografía de Coherencia Óptica/métodos , Adulto , Anciano , Capilares/diagnóstico por imagen , Capilares/patología , Estudios de Casos y Controles , Coroides/diagnóstico por imagen , Estudios Transversales , Retinopatía Diabética/diagnóstico por imagen , Femenino , Angiografía con Fluoresceína , Humanos , Masculino , Microvasos/patología , Persona de Mediana Edad , Estudios Prospectivos , Flujo Sanguíneo Regional , Retina/diagnóstico por imagen , Retina/fisiopatología , Neovascularización Retiniana/diagnóstico por imagen , Neovascularización Retiniana/patología , Vasos Retinianos/diagnóstico por imagen , Vasos Retinianos/patología , Adulto Joven
7.
Retina ; 36 Suppl 1: S2-S11, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28005659

RESUMEN

PURPOSE: To investigate choriocapillaris (CC) alteration in patients with nascent geographic atrophy (nGA) and/or drusen-associated geographic atrophy (DAGA) using swept-source optical coherence tomography angiography (OCTA). METHODS: A 1,050-nm wavelength, 400 kHz A-scan rate swept-source optical coherence tomography prototype was used to perform volumetric swept-source optical coherence tomography angiography over 6 mm × 6 mm fields of view in patients with nGA and/or DAGA. The resulting optical coherence tomography (OCT) and OCTA data were analyzed using a combination of en face and cross-sectional techniques. Variable interscan time analysis (VISTA) was used to differentiate CC flow impairment from complete CC atrophy. RESULTS: A total of 7 eyes from 6 patients (mean age: 73.8 ± 5.7 years) were scanned. Seven areas of nGA and three areas of DAGA were identified. Analysis of cross-sectional OCT and OCTA images identified focal alterations of the CC underlying all seven areas of nGA and all three areas of DAGA. En face OCTA analysis of the CC revealed diffuse CC alterations in all eyes. Variable interscan time analysis processing suggested that the observed CC flow alterations predominantly corresponded to flow impairment rather than complete CC atrophy. CONCLUSION: The OCTA imaging of the CC revealed focal CC flow impairment associated with areas of nGA and DAGA, as well as diffuse CC flow impairment throughout the imaged field. En face OCT analysis should prove useful for understanding the pathogenesis of nGA and DAGA and for identifying the formation of nGA and DAGA as endpoints in therapeutic trials.


Asunto(s)
Coroides/irrigación sanguínea , Atrofia Geográfica/diagnóstico por imagen , Drusas del Disco Óptico/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos , Anciano , Artefactos , Angiografía por Tomografía Computarizada/métodos , Femenino , Atrofia Geográfica/etiología , Humanos , Masculino , Drusas del Disco Óptico/complicaciones
8.
Retina ; 36 Suppl 1: S93-S101, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28005667

RESUMEN

PURPOSE: To develop a robust, sensitive, and fully automatic algorithm to quantify diabetes-related capillary dropout using optical coherence tomography (OCT) angiography (OCTA). METHODS: A 1,050-nm wavelength, 400 kHz A-scan rate swept-source optical coherence tomography prototype was used to perform volumetric optical coherence tomography angiography imaging over 3 mm × 3 mm fields in normal controls (n = 5), patients with diabetes without diabetic retinopathy (DR) (n = 7), patients with nonproliferative diabetic retinopathy (NPDR) (n = 9), and patients with proliferative diabetic retinopathy (PDR) (n = 5); for each patient, one eye was imaged. A fully automatic algorithm to quantify intercapillary areas was developed. RESULTS: Of the 26 evaluated eyes, the segmentation was successful in 22 eyes (85%). The mean values of the 10 and 20 largest intercapillary areas, either including or excluding the foveal avascular zone, showed a consistent trend of increasing size from normal control eyes, to eyes with diabetic retinopathy but without diabetic retinopathy, to nonproliferative diabetic retinopathy eyes, and finally to PDR eyes. CONCLUSION: Optical coherence tomography angiography-based screening and monitoring of patients with diabetic retinopathy is critically dependent on automated vessel analysis. The algorithm presented was able to automatically extract an intercapillary area-based metric in patients having various stages of diabetic retinopathy. Intercapillary area-based approaches are likely more sensitive to early stage capillary dropout than vascular density-based methods.


Asunto(s)
Capilares/diagnóstico por imagen , Diabetes Mellitus Tipo 1/diagnóstico por imagen , Diabetes Mellitus Tipo 2/diagnóstico por imagen , Retinopatía Diabética/diagnóstico por imagen , Vasos Retinianos/diagnóstico por imagen , Algoritmos , Estudios de Casos y Controles , Humanos , Estudios Retrospectivos , Tomografía de Coherencia Óptica/métodos
9.
Retina ; 36 Suppl 1: S118-S126, 2016 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28005670

RESUMEN

PURPOSE: Currently available optical coherence tomography angiography systems provide information about blood flux but only limited information about blood flow speed. The authors develop a method for mapping the previously proposed variable interscan time analysis (VISTA) algorithm into a color display that encodes relative blood flow speed. METHODS: Optical coherence tomography angiography was performed with a 1,050 nm, 400 kHz A-scan rate, swept source optical coherence tomography system using a 5 repeated B-scan protocol. Variable interscan time analysis was used to compute the optical coherence tomography angiography signal from B-scan pairs having 1.5 millisecond and 3.0 milliseconds interscan times. The resulting VISTA data were then mapped to a color space for display. RESULTS: The authors evaluated the VISTA visualization algorithm in normal eyes (n = 2), nonproliferative diabetic retinopathy eyes (n = 6), proliferative diabetic retinopathy eyes (n = 3), geographic atrophy eyes (n = 4), and exudative age-related macular degeneration eyes (n = 2). All eyes showed blood flow speed variations, and all eyes with pathology showed abnormal blood flow speeds compared with controls. CONCLUSION: The authors developed a novel method for mapping VISTA into a color display, allowing visualization of relative blood flow speeds. The method was found useful, in a small case series, for visualizing blood flow speeds in a variety of ocular diseases and serves as a step toward quantitative optical coherence tomography angiography.


Asunto(s)
Retinopatía Diabética/fisiopatología , Atrofia Geográfica/fisiopatología , Algoritmos , Velocidad del Flujo Sanguíneo/fisiología , Estudios de Casos y Controles , Coroides/irrigación sanguínea , Angiografía por Tomografía Computarizada/métodos , Retinopatía Diabética/diagnóstico por imagen , Atrofia Geográfica/diagnóstico por imagen , Humanos , Persona de Mediana Edad , Imagen Multimodal , Tomografía de Coherencia Óptica/métodos
10.
Ophthalmology ; 122(12): 2532-44, 2015 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-26481819

RESUMEN

PURPOSE: To investigate ultrahigh-speed, swept-source optical coherence tomography (SSOCT) angiography for visualizing vascular changes in eyes with nonexudative age-related macular degeneration (AMD) with geographic atrophy (GA). DESIGN: Observational, prospective, cross-sectional study. PARTICIPANTS: A total of 63 eyes from 32 normal subjects and 12 eyes from 7 patients with nonexudative AMD with GA. METHODS: A 1050-nm, 400-kHz A-scan rate SSOCT system was used to perform volumetric optical coherence tomography angiography (OCTA) of the retinal and choriocapillaris (CC) vasculatures in normal subjects and patients with nonexudative AMD with GA. Optical coherence tomography angiography using variable interscan time analysis (VISTA) was performed to assess CC alteration and differentiate varying degrees of CC flow impairment. MAIN OUTCOME MEASURES: Qualitative comparison of retinal and CC vasculatures in normal subjects versus those in patients with a clinical diagnosis of nonexudative AMD with GA. RESULTS: In all 12 eyes with GA, OCTA showed pronounced CC flow impairment within the region of GA. In 10 of the 12 eyes with GA, OCTA with VISTA showed milder CC flow impairment extending beyond the margin of GA. Of the 5 eyes exhibiting foveal-sparing GA, OCTA showed CC flow within the region of foveal sparing in 4 of the eyes. CONCLUSIONS: The ability of ultrahigh-speed, swept-source OCTA to noninvasively visualize alterations in the retinal and CC vasculatures makes it a promising tool for assessing nonexudative AMD with GA. Optical coherence tomography angiography using VISTA can distinguish varying degrees of CC alteration and flow impairment and may be useful for elucidating disease pathogenesis, progression, and response to therapy.


Asunto(s)
Coroides/irrigación sanguínea , Atrofia Geográfica/fisiopatología , Degeneración Macular/fisiopatología , Vasos Retinianos/patología , Adulto , Anciano , Anciano de 80 o más Años , Velocidad del Flujo Sanguíneo , Estudios Transversales , Femenino , Angiografía con Fluoresceína , Atrofia Geográfica/diagnóstico , Humanos , Degeneración Macular/diagnóstico , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Flujo Sanguíneo Regional , Tomografía de Coherencia Óptica
11.
Teach Learn Med ; 27(1): 51-6, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25584471

RESUMEN

UNLABELLED: CONSTRUCT: With the current shift toward competency-based education, rigorous assessment tools are needed for procedurally based tasks. BACKGROUND: Multiple tools exist to evaluate procedural skills, each with specific weaknesses. APPROACH: We sought to determine if quantitative needle tracking could be used as a measure of lumbar puncture (LP) performance and added discriminatory value to a dichotomous checklist. Thirty-two medical students were divided into 2 groups. One group was asked to practice an LP once (single practice [SP]) and the other 5 times (multiple practice [MP]). Experts (attending ER physicians, senior ER residents, and a junior anesthesia resident) were used as comparators. Medical students were assessed again at 1 month to assess skill retention. Groups were assessed performing an LP with an electromagnetic tracking device that allows the needle's 3-dimensional movements to be captured and analyzed, and a dichotomous checklist. RESULTS: Quantitative needle metrics as assessed by electromagnetic tracking showed a decreasing trend in needle movement distance with practice and with experience. The SP group made significantly more checklist mistakes initially as compared to the MP group (1.2 vs. 0.3, p <.05). At 1 month, there was a significant increase in both groups' mistakes (SP 3.4 vs. MP 1.3, p =.01). No correlation existed between individuals' needle motion and checklist mistakes. CONCLUSIONS: These findings suggest that quantitative needle tracking identifies students who struggle with needle insertion but are successful at completing the dichotomous checklist.


Asunto(s)
Competencia Clínica , Educación Basada en Competencias , Educación de Pregrado en Medicina , Evaluación Educacional , Punción Espinal/normas , Adulto , Lista de Verificación , Femenino , Humanos , Masculino , Proyectos Piloto
12.
bioRxiv ; 2024 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-38370720

RESUMEN

Uterine contraction patterns vary during the ovulatory cycle and throughout pregnancy but prior measurements have produced limited and conflicting information on these patterns. We combined a virally delivered genetically encoded calcium reporter (GCaMP8m) and ultra-widefield imaging in live nonpregnant mice to characterize uterine calcium dynamics at organ scale throughout the estrous cycle. Prior to ovulation (proestrus and estrus) uterine excitations primarily initiated in a region near the oviduct, but after ovulation (metestrus and diestrus), excitations initiated at loci homogeneously distributed throughout the organ. The frequency of excitation events was lowest in proestrus and estrus, higher in metestrus and highest in diestrus. These results establish a platform for mapping uterine activity, and show that the question of whether there is an anatomically localized trigger for uterine excitations depends on the estrous cycle phase.

13.
Invest Ophthalmol Vis Sci ; 65(1): 33, 2024 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-38236187

RESUMEN

Purpose: To assess the relationship between choriocapillaris (CC) loss and the development of nascent geographic atrophy (nGA) using optical coherence tomography angiography (OCTA) imaging. Methods: In total, 105 from 62 participants with bilateral large drusen, without late age-related macular degeneration (AMD) or nGA at baseline, were included in this prospective, longitudinal, observational study. Participants underwent swept-source OCTA imaging at 6-month intervals. CC flow deficit percentage (FD%) and drusen volume measurements were determined for the visit prior to nGA development or the second-to-last visit if nGA did not develop. Global and local analyses, the latter based on analyses within superpixels (120 × 120-µm regions), were performed to examine the association between CC FD% and future nGA development. Results: A total of 15 (14%) eyes from 12 (19%) participants developed nGA. There was no significant difference in global CC FD% at the visit prior to nGA development between eyes that developed nGA and those that did not (P = 0.399). In contrast, CC FD% was significantly higher in superpixels that subsequently developed nGA compared to those that did not (P < 0.001), and a model utilizing CC FD% was significantly better at predicting foci of future nGA development at the superpixel level than a model using drusen volume alone (P ≤ 0.040). Conclusions: This study showed that significant impairments in CC blood flow could be detected locally prior to the development of nGA. These findings add to our understanding of the pathophysiologic changes that occur with atrophy development in AMD.


Asunto(s)
Atrofia Geográfica , Degeneración Macular , Humanos , Tomografía de Coherencia Óptica , Atrofia Geográfica/diagnóstico , Estudios Prospectivos , Coroides , Degeneración Macular/diagnóstico , Angiografía
14.
Clin Orthop Relat Res ; 471(12): 4047-55, 2013 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-23955194

RESUMEN

BACKGROUND: Computerized navigation improves the accuracy of minimally invasive pedicle screw placement during spine surgery. Such navigation, however, exposes both the patient and the staff to radiation during surgery. To avoid intraoperative exposure to radiation, tracked ultrasound snapshots-ultrasound image frames coupled with corresponding spatial positions-could be used to map preoperatively defined screw plans into the intraoperative coordinate frame. The feasibility of such an approach, however, has not yet been investigated. QUESTIONS/PURPOSES: Are there vertebral landmarks that can be identified using tracked ultrasound snapshots? Can tracked ultrasound snapshots allow preoperative pedicle screw plans to be accurately mapped--compared with CT-derived pedicle screw plans--into the intraoperative coordinate frame in a simulated setting? METHODS: Ultrasound visibility of registration landmarks was checked on volunteers and phantoms. An ultrasound machine with integrated electromagnetic tracking was used for tracked ultrasound acquisition. Registration was performed using 3D Slicer open-source software (www.slicer.org). Two artificial lumbar spine phantoms were used to evaluate registration accuracy of pedicle screw plans using tracked ultrasound snapshots. Registration accuracy was determined by comparing the ultrasound-derived plans with the CT-derived plans. RESULTS: The four articular processes proved to be identifiable using tracked ultrasound snapshots. Pedicle screw plans were registered to the intraoperative coordinate system using landmarks. The registrations were sufficiently accurate in that none of the registered screw plans intersected the pedicle walls. Registered screw plan positions had an error less than 1.28 ± 1.37 mm (average ± SD) in each direction and an angle difference less than 1.92° ± 1.95° around each axis relative to the CT-derived positions. CONCLUSIONS: Registration landmarks could be located using tracked ultrasound snapshots and permitted accurate mapping of pedicle screw plans to the intraoperative coordinate frame in a simulated setting. CLINICAL RELEVANCE: Tracked ultrasound may allow accurate computer-navigated pedicle screw placement while avoiding ionizing radiation in the operating room; however, further studies that compare this approach with other navigation techniques are needed to confirm the practical use of this new approach.


Asunto(s)
Vértebras Lumbares/cirugía , Monitoreo Intraoperatorio/métodos , Procedimientos Ortopédicos/métodos , Cirugía Asistida por Computador/métodos , Vértebras Torácicas/cirugía , Tornillos Óseos , Estudios de Factibilidad , Femenino , Humanos , Vértebras Lumbares/diagnóstico por imagen , Masculino , Vértebras Torácicas/diagnóstico por imagen , Ultrasonografía
15.
bioRxiv ; 2023 Dec 07.
Artículo en Inglés | MEDLINE | ID: mdl-37292614

RESUMEN

A tool to map changes in synaptic strength during a defined time window could provide powerful insights into the mechanisms governing learning and memory. We developed a technique, Extracellular Protein Surface Labeling in Neurons (EPSILON), to map α-amino-3-hydroxy-5-methyl-4-isoxazolepropionic acid receptor (AMPAR) insertion in vivo by pulse-chase labeling of surface AMPARs with membrane-impermeable dyes. This approach allows for single-synapse resolution maps of plasticity in genetically targeted neurons during memory formation. We investigated the relationship between synapse-level and cell-level memory encodings by mapping synaptic plasticity and cFos expression in hippocampal CA1 pyramidal cells upon contextual fear conditioning (CFC). We observed a strong correlation between synaptic plasticity and cFos expression, suggesting a synaptic mechanism for the association of cFos expression with memory engrams. The EPSILON technique is a useful tool for mapping synaptic plasticity and may be extended to investigate trafficking of other transmembrane proteins.

16.
Ophthalmic Surg Lasers Imaging Retina ; 54(2): 114-122, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36780632

RESUMEN

BACKGROUND AND OBJECTIVE: The purpose of this article is to demonstrate the optical coherence tomography angiography (OCTA) Analysis Toolkit (OAT), a custom-designed software package, as a repeatable and reproducible tool for computing OCTA metrics across different devices. MATERIALS AND METHODS: Fourteen participants were imaged using three devices. Foveal avascular zone, vessel index, vessel length index, and vessel diameter index were calculated using the OAT. Repeatability and reproducibility were assessed using the coefficient of variation and interclass correlation coefficient (ICC). RESULTS: Analysis of identical images demonstrated perfect levels of repeatability for all metrics (coefficient of variation 0%), which was a consequence of the software being deterministic (ie, producing the same outputs for the same inputs). Foveal avascular zone ICC values were in the excellent-to-good range (ICC > 0.6) for all devices. All values for vessel index (VI), vessel length index, and vessel diameter index fell in the good-to-fair (ICC > 0.4) or excellent-to-good range, except for vessel index analysis in the Cirrus device (ICC = 0.34). CONCLUSIONS: The OAT appears to be a reliable tool that may enable comparison between OCTA data sets acquired on different imaging instruments, thereby facilitating a more consistent approach to OCTA analysis. [Ophthalmic Surg Lasers Imaging Retina 2023;54:114-122.].


Asunto(s)
Vasos Retinianos , Tomografía de Coherencia Óptica , Humanos , Vasos Retinianos/diagnóstico por imagen , Angiografía con Fluoresceína/métodos , Tomografía de Coherencia Óptica/métodos , Reproducibilidad de los Resultados , Programas Informáticos
17.
Nat Biotechnol ; 41(5): 631-639, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36593408

RESUMEN

Recording transcriptional histories of a cell would enable deeper understanding of cellular developmental trajectories and responses to external perturbations. Here we describe an engineered protein fiber that incorporates diverse fluorescent marks during its growth to store a ticker tape-like history. An embedded HaloTag reporter incorporates user-supplied dyes, leading to colored stripes that map the growth of each individual fiber to wall clock time. A co-expressed eGFP tag driven by a promoter of interest records a history of transcriptional activation. High-resolution multi-spectral imaging on fixed samples reads the cellular histories, and interpolation of eGFP marks relative to HaloTag timestamps provides accurate absolute timing. We demonstrate recordings of doxycycline-induced transcription in HEK cells and cFos promoter activation in cultured neurons, with a single-cell absolute accuracy of 30-40 minutes over a 12-hour recording. The protein-based ticker tape design we present here could be generalized to achieve massively parallel single-cell recordings of diverse physiological modalities.


Asunto(s)
Neuronas , Proteínas , Neuronas/fisiología , Regiones Promotoras Genéticas , Proteínas Fluorescentes Verdes/genética
18.
Biomed Opt Express ; 14(6): 2658-2677, 2023 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-37342704

RESUMEN

Optical coherence tomography angiography (OCTA) can visualize vasculature structures, but provides limited information about blood flow speed. Here, we present a second generation variable interscan time analysis (VISTA) OCTA, which evaluates a quantitative surrogate marker for blood flow speed in vasculature. At the capillary level, spatially compiled OCTA and a simple temporal autocorrelation model, ρ(τ) = exp(-ατ), were used to evaluate a temporal autocorrelation decay constant, α, as the blood flow speed marker. A 600 kHz A-scan rate swept-source OCT prototype instrument provides short interscan time OCTA and fine A-scan spacing acquisition, while maintaining multi mm2 field of views for human retinal imaging. We demonstrate the cardiac pulsatility and assess repeatability of α measured with VISTA. We show different α for different retinal capillary plexuses in healthy eyes and present representative VISTA OCTA in eyes with diabetic retinopathy.

19.
Am J Ophthalmol ; 254: 11-22, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-36958537

RESUMEN

PURPOSE: The appearance and growth of persistent choroidal hypertransmission defects (hyperTDs) detected on en face swept-source optical coherence tomography (SS-OCT) images from eyes with intermediate age-related macular degeneration (iAMD) were studied to determine if they could serve as novel clinical trial endpoints. DESIGN: Post hoc subgroup analysis of a prospective study. METHODS: Subjects with iAMD underwent 6 × 6 mm SS-OCT angiography imaging at their baseline and follow-up visits. The drusen volumes were obtained using a validated SS-OCT algorithm. Two graders independently evaluated all en face structural images for the presence of persistent hyperTDs. The number and area of all hyperTDs along with drusen volume were obtained from all SS-OCT angiography scans. Eyes were censored from further follow-up once exudative AMD developed. RESULTS: A total of 171 eyes from 121 patients with iAMD were included. Sixty-eight eyes developed at least 1 hyperTD. Within 1 year after developing a hyperTD, 25% of eyes developed new hyperTDs for an average of 0.44 additional hyperTDs. Over 2 years, as hyperTDs appeared, enlarged, and merged, the average area growth rate was 0.220 mm/yr using the square-root transformation strategy. A clinical trial design using the onset and enlargement of these hyperTDs for the study of disease progression in eyes with iAMD is proposed. CONCLUSIONS: The appearance and growth of persistent choroidal hyperTDs in eyes with iAMD can be easily detected and measured using en face OCT imaging and can serve as novel clinical trial endpoints for the study of therapies that may slow disease progression from iAMD to late AMD.


Asunto(s)
Degeneración Macular , Humanos , Progresión de la Enfermedad , Angiografía con Fluoresceína/métodos , Degeneración Macular/diagnóstico , Estudios Prospectivos , Retina , Ensayos Clínicos como Asunto
20.
Ophthalmol Sci ; 3(3): 100277, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36970115

RESUMEN

Purpose: Ultrahigh resolution spectral domain-OCT (UHR SD-OCT) enables in vivo visualization of micrometric structural markers which differentially associate with normal aging versus age-related macular degeneration (AMD). This study explores the hypothesis that UHR SD-OCT can detect and quantify sub-retinal pigment epithelium (RPE) deposits in early AMD, separating AMD pathology from normal aging. Design: Prospective cross-sectional study. Participants: A total of 53 nonexudative (dry) AMD eyes from 39 patients, and 63 normal eyes from 39 subjects. Methods: Clinical UHR SD-OCT scans were performed using a high-density protocol. Exemplary high-resolution histology and transmission electron microscopy images were obtained from archive donor eyes. Three trained readers evaluated and labeled outer retina morphological features, including the appearance of a hyporeflective split within the RPE-RPE basal lamina (RPE-BL)-Bruch's membrane (BrM) complex on UHR brightness (B)-scans. A semi-automatic segmentation algorithm measured the thickness of the RPE-BL-BrM split/hyporeflective band. Main Outcome Measures: Qualitative description of outer retinal morphological changes on UHR SD-OCT B-scans; the proportion of the RPE-BL-BrM complex with visible split (%) and the thickness of the resulting hyporeflective band (µm). Results: In young normal eyes, UHR SD-OCT consistently revealed an RPE-BL-BrM split/hyporeflective band. Its visibility and thickness were less in eyes of advanced age. However, the split/hyporeflective band was again visible in early AMD eyes. Both qualitative reading and quantitative thickness measurements showed significantly elevated visibility and thickness of the RPE-BL-BrM split/hyporeflective in early AMD eyes compared to age-matched controls. Conclusions: Our imaging results strongly support the hypothesis that appearance of the RPE-BL-BrM split/hyporeflective band in older subjects is dominated by the BL deposit, an indicator of early AMD well known from histology. Ultrahigh resolution SD-OCT can be used to investigate physiological aging as well as early AMD pathology in clinical imaging studies. Developing quantifiable markers associated with disease pathogenesis and progression can facilitate drug discovery, as well as reduce clinical trial times. Financial Disclosures: Proprietary or commercial disclosure may be found after the references.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA