RESUMEN
BACKGROUND: Pathologic fractures of the pelvis/sacrum due to metastatic bone disease (MBD) cause pain and dysfunction due to mechanical instability of the pelvic ring. This study presents our multi-institutional experience with percutaneous stabilization of pathologic fractures and osteolytic lesions from MBD throughout the pelvic ring. METHODS: The records of patients undergoing this procedure from 2018 to 2022 were reviewed retrospectively from two institutions. Surgical data and functional outcomes were recorded. RESULTS: Fifty-six patients underwent percutaneous stabilization, with a median operative duration of 119 min (interquartile range [IQR]: 92.8, 167) and median estimated blood loss of 50 mL (IQR: 20, 100). The median length of stay was 3 days (IQR: 1, 6), and 69.6% (n = 39) of patients were discharged home. Early complications included one partial lumbosacral plexus injury, three acute kidney injuries, and one case of intra-articular cement extravasation. Late complications included two infections and one revision stabilization procedure for hardware failure. Mean Eastern Cooperative Oncology Group (ECOG) scores improved from 3.02 (SD 0.8) preoperatively to 1.86 (SD 1.1) postoperatively (p < 0.001). Ambulatory status also improved (p < 0.001). CONCLUSIONS: Percutaneous stabilization of pathologic fractures and osteolytic defects of the pelvis and sacrum is a procedure that improves patient function, ambulatory status and is associated with a limited complication profile.
Asunto(s)
Fracturas Óseas , Fracturas Espontáneas , Neoplasias , Huesos Pélvicos , Humanos , Fijación Interna de Fracturas/métodos , Fracturas Óseas/cirugía , Fracturas Espontáneas/etiología , Fracturas Espontáneas/cirugía , Huesos Pélvicos/cirugía , Pelvis , Estudios Retrospectivos , Sacro/cirugíaRESUMEN
STUDY DESIGN: Retrospective database review. OBJECTIVE: To analyze and report the trends and cost of posterior cervical fusions (PCFs) with and without off-label recombinant human bone morphogenetic protein-2 (rhBMP-2) in the Medicare population. METHODS: Patient records from the PearlDiver database were retrospectively reviewed from January 1, 2005, to December 31, 2012, to distinguish individuals who underwent a PCF with or without rhBMP-2. Total numbers, incidence, age, gender, geographic region, reimbursement, and length of stay were analyzed and summarized. RESULTS: The combined total of non-rhBMP-2 (n = 39 479; 85.51%) and rhBMP-2 PCF (n = 6692; 14.49%) procedures performed between 2005 and 2012 was 46 171. In general, the number of PCFs without rhBMP-2 consistently increased over time, while the number of PCFs with rhBMP-2 had only a slight increase from 2005 to 2012. On average, PCFs without rhBMP-2 were associated with $1197 higher cost than those with rhBMP-2, but the average length of stay was similar (6 days). From 2005 to 2012, the average cost for procedures with and without rhBMP-2 increased by $12 605 and $7291, respectively. The percentage of rhBMP-2 use peaked in 2007 and dwindled until 2010, and declined an additional 2.84% from 2011 to 2012. Multiple age, region, and gender tendencies were observed. CONCLUSIONS: To our knowledge, this was the first study to use the PearlDiver database to report incidence and cost trends of PCF procedures. This article provides meaningful trend data on PCFs to surgeons and clinicians, researchers, and patients, as well as functions as a beacon for future research questions.
RESUMEN
STUDY DESIGN: A literature review. OBJECTIVE: The purpose of this study was to review lumbar segmental and regional alignment changes following treatment with a variety of minimally invasive surgery (MIS) interbody fusion procedures for short-segment, degenerative conditions. SUMMARY OF BACKGROUND DATA: An increasing number of lumbar fusions are being performed with minimally invasive exposures, despite a perception that minimally invasive lumbar interbody fusion procedures are unable to affect segmental and regional lordosis. METHODS: Through a MEDLINE and Google Scholar search, a total of 23 articles were identified that reported alignment following minimally invasive lumbar fusion for degenerative (nondeformity) lumbar spinal conditions to examine aggregate changes in postoperative alignment. RESULTS: Of the 23 studies identified, 28 study cohorts were included in the analysis. Procedural cohorts included MIS ALIF (two), extreme lateral interbody fusion (XLIF) (16), and MIS posterior/transforaminal lumbar interbody fusion (P/TLIF) (11). Across 19 study cohorts and 720 patients, weighted average of lumbar lordosis preoperatively for all procedures was 43.5° (range 28.4°-52.5°) and increased 3.4° (9%) (range -2° to 7.4°) postoperatively (Pâ<â0.001). Segmental lordosis increased, on average, by 4° from a weighted average of 8.3° preoperatively (range -0.8° to 15.8°) to 11.2° at postoperative time points (range -0.2° to 22.8°) (Pâ<â0.001) in 1182 patient from 24 study cohorts. Simple linear regression revealed a significant relationship between preoperative lumbar lordosis and change in lumbar lordosis (râ=â0.413; Pâ=â0.003), wherein lower preoperative lumbar lordosis predicted a greater increase in postoperative lumbar lordosis. CONCLUSION: Significant gains in both weighted average lumbar lordosis and segmental lordosis were seen following MIS interbody fusion. None of the segmental lordosis cohorts and only two of the 19 lumbar lordosis cohorts showed decreases in lordosis postoperatively. These results suggest that MIS approaches are able to impact regional and local segmental alignment and that preoperative patient factors can impact the extent of correction gained (preserving vs. restoring alignment). LEVEL OF EVIDENCE: 4.
Asunto(s)
Lordosis , Vértebras Lumbares , Procedimientos Quirúrgicos Mínimamente Invasivos , Fusión Vertebral , Humanos , Lordosis/fisiopatología , Lordosis/cirugía , Vértebras Lumbares/fisiopatología , Vértebras Lumbares/cirugía , Procedimientos Quirúrgicos Mínimamente Invasivos/efectos adversos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/estadística & datos numéricos , Análisis de Regresión , Fusión Vertebral/efectos adversos , Fusión Vertebral/métodos , Fusión Vertebral/estadística & datos numéricos , Resultado del TratamientoRESUMEN
The purpose of this review was to compare the efficacy and safety of synthetic bone graft substitutes versus autograft or allograft for the treatment of lumbar and cervical spinal degenerative diseases. Multiple major medical reference databases were searched for studies that evaluated spinal fusion using synthetic bone graft substitutes (either alone or with an autograft or allograft) compared with autograft and allograft. Randomized controlled trials (RCT) and cohort studies with more than 10 patients were included. Radiographic fusion, patient-reported outcomes, and functional outcomes were the primary outcomes of interest. The search yielded 214 citations with 27 studies that met the inclusion criteria. For the patients with lumbar spinal degenerative disease, data from 19 comparative studies were included: 3 RCTs, 12 prospective, and 4 retrospective studies. Hydroxyapatite (HA), HA+collagen, ß-tricalcium phosphate (ß-TCP), calcium sulfate, or polymethylmethacrylate (PMMA) were used. Overall, there were no differences between the treatment groups in terms of fusion, functional outcomes, or complications, except in 1 study that found higher rates of HA graft absorption. For the patients with cervical degenerative conditions, data from 8 comparative studies were included: 4 RCTs and 4 cohort studies (1 prospective and 3 retrospective studies). Synthetic grafts included HA, ß-TCP/HA, PMMA, and biocompatible osteoconductive polymer (BOP). The PMMA and BOP grafts led to lower fusion rates, and PMMA, HA, and BOP had greater risks of graft fragmentation, settling, and instrumentation problems compared with iliac crest bone graft. The overall quality of evidence evaluating the potential use and superiority of the synthetic biological materials for lumbar and cervical fusion in this systematic review was low or insufficient, largely due to the high potential for bias and small sample sizes. Thus, definitive conclusions or recommendations regarding the use of these synthetic materials should be made cautiously and within the context of the limitations of the evidence.