Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
Más filtros

Banco de datos
Tipo del documento
Intervalo de año de publicación
1.
Chemistry ; 30(32): e202304275, 2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-38575394

RESUMEN

Optically active poly(naphthalene-1,4-diyl) was prepared through helix-sense-selective polymerization of the corresponding monomers and also through circularly polarized light (CPL) irradiation, resulting in distinctive circular dichroism (CD) spectral patterns. Chirality of the helix-sense-selective polymerization -based polymer is ascribed to preferred-handed helicity while that of the CPL-based polymer to a non-helical, chiral conformation ('biased-dihedral conformation') with preferred-handedness which was stable only in the solid state. The helix of the helix-sense-selective polymerization-based polymer gradually racemized in tetrahydrofuran while it was stabilized by aggregate formation in a hexane-dichloromethane solution. Both helix-sense-selective polymerization- and CPL-based polymers exhibited efficient circularly polarized luminescence.

2.
J Prosthet Dent ; 130(3): 381.e1-381.e7, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37482533

RESUMEN

STATEMENT OF PROBLEM: Altering the internal design of 3-dimensionally (3D) printed dental casts may help to reduce material and time consumption. However, it remains unclear whether such changes would compromise the accuracy of the casts. Further research is also needed to determine the optimal internal design that would maximize printing accuracy. PURPOSE: The purpose of this in vitro study was to evaluate the impact of internal design on the accuracy (trueness and precision) of 3D printed dental casts fabricated by stereolithography (SLA) and digital light processing (DLP) technology. MATERIAL AND METHODS: A reference digital cast was obtained by scanning a maxillary typodont with an intraoral scanner to create 4 types of internal designs, including hollow interior with perforated base (HWB), hollow interior without base (HB), all solid (S), and internal support structure with perforated base (SWB). Digital casts with different internal designs were printed by two 3D printers with different technologies (SLA and DLP). The printed casts were scanned by a desktop scanner to obtain standard tessellation language (STL) format research digital casts. All reference and research digital casts were imported into a software program for comparison and analysis of accuracy. Differences between the reference and research digital casts were quantitatively indicated by the root mean square (RMS) value. The Kruskal-Wallis 1-way ANOVA was used to test significant differences between the different internal design types and the Mann-Whitney U test was used to test significant differences between the two 3D printers (α=.05). RESULTS: The Kruskal-Wallis 1-way ANOVA revealed significant differences in the trueness and precision of different internal design types (all P<.001) for casts printed by both 3D printers. The trueness and precision were significantly worse for the HB design than for the other design types for casts printed by both 3D printers (all P<.05). Regardless of the design type, the trueness was significantly better for casts printed by the SLA-based printer than for casts printed by the DLP-based printer (all P<.05). The precision was significantly worse for casts printed by the SLA-based printer than for casts printed by the DLP-based printer (all P<.05). CONCLUSIONS: The internal design may affect the accuracy of 3D printing. The base is necessary to ensure the accuracy of 3D printed dental casts, whereas the internal support structure did not affect the accuracy of 3D printed dental casts. An all-solid design led to higher precision, but not higher trueness. Dental casts printed with SLA technology have higher trueness and lower precision than those printed with DLP technology.


Asunto(s)
Diseño Asistido por Computadora , Estereolitografía , Modelos Dentales , Impresión Tridimensional , Maxilar
3.
Angew Chem Int Ed Engl ; 62(29): e202305747, 2023 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-37204160

RESUMEN

Optically active, hyperbranched, poly(fluorene-2,4,7-triylethene-1,2-diyl) [poly(fluorenevinylene)] derivatives bearing a neomenthyl group and a pentyl group at the 9-position of the fluorene backbone at various ratios acted as a chirality donor (host polymers) efficiently included naphthalene, anthracene, pyrene, 9-phenylanthracene, and 9,10-diphenyanthracene as a chirality acceptor (guest molecules) in their interior space in film as well as in solution, with the guest molecules exhibiting intense circular dichroism through chirality transfer with chirality amplification. The efficiency of the chirality transfer was much higher with higher-molar-mass polymers than lower-molar-mass ones as well as with hyperbranched polymers compared to the analogous linear ones. The hyperbranched polymers include the small molecules in their complex structure without any specific interactions at various stoichiometries. The included molecules may have ordered intermolecular arrangement that may be somewhat similar to those of liquid crystals. Naphthalene, anthracene, and pyrene included in the polymer exhibited efficient circularly polarized luminescence, where the chirality was remarkably amplified in excited states, and anthracene exhibited especially high anisotropies in the emission on the order of 10-2 .

4.
Chirality ; 34(2): 317-324, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34939234

RESUMEN

Photo racemization of 2,2'-dihydroxy-1,1'-binaphthyl (BINOL) and its monomethyl ether, monobutyl ether, and dimethyl ether was studied by means of circularly dichroism spectra, chiral HPLC, and theoretical calculations of rotation energy barriers. Racemization was fastest for BINOL and about one seventh as fast for the monomethyl and monobutyl ethers while it was too slow to be detected for the dimethyl ether under the present conditions.


Asunto(s)
Naftalenos , Cromatografía Líquida de Alta Presión , Estereoisomerismo
5.
J Prosthet Dent ; 2022 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-36528391

RESUMEN

STATEMENT OF PROBLEM: Zirconia abutments have become popular as they provide favorable esthetic outcomes. However, studies investigating how abutment material affects abutment screw torque performance and implant conical surface morphological changes in internal conical connection systems are scarce. PURPOSE: The purpose of this in vitro study was to investigate the influence of abutment material on abutment removal torque and implant conical surface morphological changes in internal conical connection implant-abutment assemblies of 2 diameters after simulated long-term oral use. MATERIAL AND METHODS: Thirty abutments of 3 materials (1-piece titanium, 1-piece zirconia, zirconia with alloy base) and 2 diameters (regular, narrow) made by the original manufacturer were connected to internal conical connection implants and subjected to a standardized artificial aging process consisting of thermal cycling and mechanical cyclic loading with parameters corresponding to anterior and posterior mastication scenarios simulating long-term oral use. An abutment removal torque test was done before and after aging. Morphological changes in the implant conical contact surface were observed with a scanning electron microscope (SEM). Initial and after-aging torque loss values were calculated and analyzed separately with 1-way ANOVA and Tukey HSD post hoc tests (α=.05). RESULTS: All specimens survived artificial aging. For initial and after-aging torque loss, the 1-piece zirconia groups showed significantly greater values (P<.001) for both diameters. In the SEM observation, the 1-piece zirconia groups showed distinct widespread surface damage while the other groups exhibited only minor damages. CONCLUSIONS: Regardless of diameter, 1-piece zirconia abutments tend to induce more abutment removal torque loss and implant conical surface morphological changes than those with metal connections, both initially and after simulated long-term oral use. Zirconia abutments with an alloy base performed similarly to 1-piece titanium abutments.

6.
J Prosthodont ; 31(1): 59-64, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33829613

RESUMEN

PURPOSE: To assess the influence of liquid attached on the tooth surfaces on the accuracy (trueness and precision) of intraoral scanners and the effectiveness of the drying method (using compression air) to exclude the influence of liquid on the scanning results. MATERIALS AND METHODS: A mandibular jaw model was scanned using an industrial computed tomography scanner to obtain a reference model. A scanning platform was designed to simulate three specific tooth surface states (dry, wet, blow-dry). Two kinds of liquids (ultra-pure water and artificial saliva) were used for the test. Two intraoral scanners (Trios 3 and Primescan) were used to scan the mandibular jaw model 10 times under each condition. All scanning data were processed and analyzed using dedicated software (Geomagic Control 2015). Trueness and precision comparison were conducted within the 12 groups of 3D models divided based on different intraoral scanners and liquids used under each condition. The root mean square (RMS) value was used to indicate the difference between the aligned virtual models. The color maps were used to evaluate and observe the deviation distribution patterns. The 3-way ANOVA (condition, intraoral scanner, liquid) followed by the Tukey test were used to assess precision and trueness. The level of significance was set at 0.05. RESULTS: The mean RMS values obtained from wet condition were significantly higher than those of the dry and blow-dry condition (p < 0.001, F = 64.033 for trueness and F = 54.866 for precision), which indicates less accurate trueness and precision for wet condition. For two different types of liquids, the mean RMS value was not significantly different on trueness and precision. The deviations caused by liquid were positive and mainly distributed in the pits and fissures of the occlusal surface of posterior teeth, the interproximal area of the teeth, and the margin of the abutments. CONCLUSIONS: Liquid on the tooth surface could affect intraoral scanning accuracy. Blow-drying with a three-way syringe can reduce scanning errors.


Asunto(s)
Técnica de Impresión Dental , Diente , Diseño Asistido por Computadora , Imagenología Tridimensional , Modelos Dentales
7.
Angew Chem Int Ed Engl ; 61(43): e202210556, 2022 Oct 24.
Artículo en Inglés | MEDLINE | ID: mdl-35959846

RESUMEN

An unprecedented non-uniform self-folding of artificial polymer chains composed of turn moieties and stretched segments is presented through the design of a set of optically active poly(fluorene-2,7-diylethene-1,2-diyl) (poly(fluorenevinylene)) derivatives bearing a neomenthyl group and a pentyl group attached at the 9-position of fluorene backbone at various ratios. The folded structure is formed and stabilized through inter-chain interactions in the solid state, leading to remarkably enhanced chiroptical properties (chirality amplification) in terms of circular dichroism (CD) and circularly polarized light (CPL) emission. This phenomenon is rationalized by experimental and theoretical CD and CPL spectral analyses. The polymer arrangements in the solid state were further assessed through transmission electron microscopic observations combined with enhanced sampling molecular dynamics simulations in the solid state revealing the thin film organizations.

8.
Chirality ; 32(5): 661-666, 2020 05.
Artículo en Inglés | MEDLINE | ID: mdl-32160652

RESUMEN

The circular dichroism spectra of a single chain of polyfluorene was predicted for a p-twisted helix conformation and local planarized polymer sections in the presence and in the absence of thermal vibrations. Under thermal vibrations at 300 K, the planarized section of polyfluorene affords a red-shifted positive dichroic band between 446 and 456 nm, preserving a degree of chirality. The S1 ← S0 excitation energy decreases from 3.29 eV, for the p-twisted helix to 2.77 or 2.71 eV, for planarized sections with one or two coplanar twists, respectively. Thermal vibrations and intramolecular rotations eventually affect the circular dichroism spectrum patterns, where planarized bent conformers induce a positive band towards 450 nm.

9.
Molecules ; 21(11)2016 Nov 16.
Artículo en Inglés | MEDLINE | ID: mdl-27854333

RESUMEN

(R)-1,1'-Bi(2-naphthol) ((R)-BINOL) in an acetonitrile solution lost optical activity upon irradiation with an Hg-Xe lamp. HPLC resolution of the product indicated that (R)-BINOL was racemized upon irradiation, and SEC analysis suggested that a polymeric product was formed in the course of racemization. It is proposed that polymerization of BINOL can occur before it is racemized and that a unit in a polymer derived from BINOL may lose its optical activity afterwards due to in-chain racemization and/or reduction. The polymeric products seem to consist not only of BINOL residues but also of residues derived from acetonitrile as well as those derived through reduction of BINOL.


Asunto(s)
Luz , Naftoles/química , Polimerizacion , Cromatografía Líquida de Alta Presión , Dicroismo Circular , Procesos Fotoquímicos , Espectroscopía de Protones por Resonancia Magnética , Estereoisomerismo
10.
Angew Chem Int Ed Engl ; 54(9): 2688-92, 2015 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-25641571

RESUMEN

A chirality-switching free-energy landscape was reconstructed on a 43-mer of poly(9,9-dioctylfluoren-2,7-diyl) (PDOF). The simulations were conducted on amorphous silica surface as well as in the vacuum phase for a single chain or for a group of sixteen chains. The achiral-to-chiral transition occurs only on amorphous silica (activation free-energy 35 kcal mol(-1) ), where the enantiomeric (homochiral) basins are detected. This was supported by the experiments where effective chirality induction to PDOF using circularly polarized light (CPL) was attained only for a film deposited on a quartz glass and not for a solution or a suspension. These results indicate that interactions of PDOF with amorphous silica play a crucial role in chirality switching. Importance of chain assembling was also indicated. Theoretical ECD spectra of the enantiomeric basins containing a 51 helix reproduce the experimental spectra.

11.
Chem Rec ; 14(3): 369-85, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24771585

RESUMEN

The following polymer structural transitions were achieved using light: preferred-handed helix formation for poly(9,9-di-n-octylfluoren-2,7-diyl), helix racemization (helix-helix transition) for poly(2,7-bis(4-t-butylphenyl)fluoren-9-yl acrylate) and poly(2,5-bis[4-((S)-2-methylbutyloxy)phenyl]styrene), and helix decomposition for poly(2,7-bis(4-t-butylphenyl)-9-methylfluoren-9-yl acrylate) and poly(2,7-bis(4-t-butylphenyl)fluoren-9-ylmethyl methacrylate). Although these types of transitions and chemical transformations have been studied mainly using heat or chemicals as stimuli, light can also cause these structural alterations. In the helix construction and the helix-helix transition, a key transition is a twist-coplanar conformational change of a biphenyl or an aryl-aryl unit in the side chain or the main chain of the polymer. Furthermore, the helix-helix transition was caused only by light and not by heat. The examples discussed in this review are expected to trigger off a new direction in synthesis and reaction of chiral polymers.

12.
J Prosthodont ; 23(6): 501-3, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27588324

RESUMEN

From the mid 1980s (approximately 10 years after titanium was first used as a medical metal), reports of suspected Ti sensitization began to emerge. In the present report,a 33-year-old Japanese woman presented with pruritus of the fingers and a specific reaction to mercury, nickel, and silver on lymphocyte stimulation testing (LST).Her condition improved after 17 restorations containing Hg or Ag were removed.Titanium and composite resin, both of which had no reaction on LST, were used in replacements of the intraoral restoration after the pruritus improved; however, cervical eczema emerged after 9 months, and repeat LST showed a specific reaction to Ti. The eczema improved after removal of the titanium. It is therefore likely that Ti allergy provoked the eczema. This report suggests that clinicians should be aware of the possibility of a titanium allergy from a dental restoration.


Asunto(s)
Coronas/efectos adversos , Restauración Dental Permanente/efectos adversos , Eccema/inducido químicamente , Hipersensibilidad/etiología , Titanio/efectos adversos , Adulto , Femenino , Humanos
13.
Clin Implant Dent Relat Res ; 26(3): 592-603, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38500194

RESUMEN

BACKGROUND: In recent years, platform switching implant treatment has been increasing, which is believed to minimize bone loss around the implant after placement. However, there have been no reports on the relationship between keratinized mucosa width (KMW) and bone loss and soft tissue recession in platform switching implants. OBJECTIVE: We evaluated the effect of the KMW on the amount of bone loss and soft tissue recession around a platform switching implant retrospectively using multivariate analysis. MATERIALS AND METHODS: This one-year retrospective study included 91 implants in 48 patients. Age, sex, a history of periodontitis, implant location, oral hygiene status, and the KMW were included as explanatory variables to evaluate bone loss (BL) and buccal gingival height (GH). Generalized estimating equations (GEEs) were used to evaluate the effect of the KMW on platform switching peri-implant tissues. RESULTS: The mean bone loss on the mesial (ΔBLm), distal (ΔBLd), and buccal (ΔBLb) sides of the implant were 0.16 ± 0.27 mm, 0.19 ± 0.34 mm, and 0.24 ± 0.50 mm, respectively, at 1 year after superstructure placement. The mean amount of change of GH (ΔGH) on the buccal side was 0.30 ± 0.47 mm. After correcting for confounders using GEEs, the results suggested that KMW <1.5 mm was a significant factor (P < 0.001) for bone loss over time in ΔBLm, ΔBLd, and ΔBLb. In addition, for soft tissues on the buccal side, KMW <1.5 mm was a significant factor for ΔGH reduction over time (P < 0.001). CONCLUSIONS: Keratinized mucosa width ≥1.5 mm was associated with a higher probability less hard and soft tissue recession around the platform switching implant after 1 year from superstructure placement.


Asunto(s)
Pérdida de Hueso Alveolar , Humanos , Estudios Retrospectivos , Femenino , Masculino , Persona de Mediana Edad , Pérdida de Hueso Alveolar/etiología , Adulto , Análisis Multivariante , Anciano , Recesión Gingival/etiología , Implantes Dentales , Mucosa Bucal , Implantación Dental Endoósea/métodos , Encía/patología , Queratinas
14.
J Hazard Mater ; 466: 133437, 2024 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-38246063

RESUMEN

A one-pot synthesis afforded a magnetic, crosslinked polymer adsorbent (m-P6) with a variety of functional groups to realize simultaneous adsorption of Cd2+, Pb2+, Hg2+, and As3+. The material was characterized by TEM-EDS, XRD, FT-IR, VSM, and XPS. Kinetic and isothermal analyses suggested mainly chemisorption processes of heavy metal ions that form multiple layers on heterogeneous surfaces. Theoretical adsorption capacities calculated by a pseudo-2nd-order kinetic model and the Sips isothermal model were 282.88 mg/g for Cd2+, 326.18 mg/g for Pb2+, 117.85 mg/g for Hg2+, and 320.29 mg/g for As3+. m-P6 not only can efficiently adsorb divalent heavy metals (Cd2+, Pb2+, Hg2+), but also demonstrate a process of adsorption-driven catalytic oxidation by single-electron transfer (SET) from As3+ to As5+. In application, in addition to adsorption in water, m-P6 is capable of minimizing matrix interference, and extracting trace heavy metals in a complex environment (cereal) through easy operations for improving the detection accuracy, as well as it is potential for application in detection of trace heavy metals in foodstuffs. m-P6 can be readily regenerated and efficiently recycled for 5 cycles using eluent E12 and dilute acid.

15.
J Am Chem Soc ; 135(15): 5509-12, 2013 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-23551335

RESUMEN

Helical polymers with switchable screw sense are versatile frameworks for chiral functional materials. In this work, we reconstructed the free energy landscape of helical poly(2,7-bis(4-tert-butylphenyl)fluoren-9-yl acrylate) [poly(BBPFA)], as its racemization is selectively driven by light without any rearrangement of chemical bonds. The chirality inversion was enforced by atomistic free energy simulations using chirality indices as reaction coordinates. The free energy landscape reproduced the experimental electronic circular dichroism spectra. We propose that the chirality inversion of poly(BBPFA) proceeds from a left-handed 31 helix via multistate free energy pathways to reach the right-handed 31 helix. The inversion is triggered by the rotation of biphenyl units with an activation barrier of 38 kcal/mol. To the best of our knowledge, this is the first report on the chiral inversion mechanism of a helical polymer determined in a quantitative way in the framework of atomistic free energy simulations.

16.
J Bone Miner Metab ; 31(1): 53-63, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23014973

RESUMEN

Evidence indicates that the balance between osteoblastogenesis and adipogenesis of mesenchymal stem cells (MSCs) is regulated by several hormones, growth factors, and their downstream signaling cascades. Previous studies suggest that retinoic acid (RA) plays a role in osteoblastogenesis and adipogenesis. However, it is unknown whether RA regulates commitment of MSCs into osteoblasts and adipocytes. In this study, we investigated the role of RA in differentiation of MSCs using the C3H10T1/2 cell line. RA stimulated activity and expression of alkaline phosphatase (ALP) and upregulated activity of the ALP gene promoter. The effects of RA were further enhanced by bone morphogenetic protein 2 (BMP2) and resultant Smad signaling. Furthermore, overexpression of Runx2 and Msx2, critical transcription factors for bone formation and BMP2-dependent osteoblastogenesis, enhanced RA-dependent ALP activity. In view of these findings, RA likely stimulates osteoblast differentiation through the BMP2-Smad-Runx2/Msx2 pathway. In contrast, RA markedly inhibited BMP2-induced adipocyte differentiation, suppressing expression of peroxisome proliferator-activated receptor-γ (PPARγ), CCAAT/enhancer-binding protein (C/EBP)α and C/EBPδ, and inhibiting adipogenic function of C/EBPß, C/EBPδ, and PPARγ. In conclusion, our data suggest that RA regulates commitment of MSCs into osteoblasts and adipocytes by controlling transcriptional regulators.


Asunto(s)
Adipocitos/metabolismo , Antineoplásicos/farmacología , Diferenciación Celular/efectos de los fármacos , Células Madre Mesenquimatosas/metabolismo , Osteoblastos/metabolismo , Tretinoina/farmacología , Adipocitos/citología , Fosfatasa Alcalina/biosíntesis , Animales , Proteína Morfogenética Ósea 2/biosíntesis , Proteína delta de Unión al Potenciador CCAAT/metabolismo , Proteínas Potenciadoras de Unión a CCAAT/metabolismo , Subunidad alfa 1 del Factor de Unión al Sitio Principal/biosíntesis , Regulación de la Expresión Génica/efectos de los fármacos , Células HEK293 , Proteínas de Homeodominio/biosíntesis , Humanos , Células Madre Mesenquimatosas/citología , Ratones , Osteoblastos/citología , PPAR gamma/metabolismo , Proteínas Smad/metabolismo , Transcripción Genética/efectos de los fármacos
17.
Clin Oral Implants Res ; 24(10): 1117-22, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22712431

RESUMEN

OBJECTIVES: The aim of this study was to devise an optical impression method that could make impressions of dental implants accurately and rapidly. MATERIALS AND METHODS: Four paper markers (4 × 3 mm, 8 × 6 mm, 16 × 12 mm, and 24 × 18 mm) and one titanium marker (8 × 6 mm) were prepared to determine the measuring accuracy of the three-dimensional optical tracker. For a proposed and conventional impression taking method, we compared the reproduction accuracies of the positions and orientations of dental implants and the times to obtain impressions. Finally, we fabricated computer-aided designing (CAD)/computer-aided manufacturing (CAM) superstructure frameworks to determine the adaptation accuracy. RESULTS: The 8 × 6-mm titanium marker was optimal among the prepared markers. Dental implants made by the proposed and conventional impression taking methods had measurement errors of 71 ± 31 µm and 32 ± 18 µm, respectively. The proposed method took a significantly shorter time to obtain an impression than did the conventional method. The connection between the CAD/CAM superstructure frameworks and four implant analogs had uplifts of 55 ± 10 µm, 94 ± 35 µm, 2 ± 1 µm, and 66 ± 3 µm. CONCLUSION: Our proposed method and fabricated titanium markers enabled us to measure the positions and orientations of dental implants both accurately and rapidly. We then used the reproducible measurement results for the positions and orientations of the dental implants to fabricate CAD/CAM superstructure frameworks within an acceptable accuracy range.


Asunto(s)
Implantes Dentales , Diseño de Prótesis Dental/instrumentación , Imagen Óptica , Algoritmos , Diseño Asistido por Computadora , Técnica de Impresión Dental , Humanos , Imagenología Tridimensional , Reproducibilidad de los Resultados , Factores de Tiempo , Titanio
18.
J Clin Med ; 12(20)2023 Oct 19.
Artículo en Inglés | MEDLINE | ID: mdl-37892753

RESUMEN

The clinical requirement for a good esthetic result for immediate implant placement is the absence of dehiscence in the anterior facial alveolar bone. In the presence of dehiscence, it is recommended to use a connective tissue graft in addition to immediate implant placement or to change to early implant placement. However, the literature focusing on dehiscence is scarce, and the influence of different placement times and combined use of connective tissue graft on postoperative esthetics in cases with dehiscence is unclear. Therefore, we quantitatively evaluated the pre-extraction dehiscence morphology and postoperative changes in the facial tissue of implants in three groups: immediate implant placement (Group I), immediate implant placement with connective tissue graft (Group IC), and early implant placement (Group E). To this end, 52 implants were obtained (20 in Group I, 16 in Group IC, and 16 in Group E). A wider dehiscence increases the risk of soft tissue regression, which was one reason for choosing early implant placement. A combination of immediate implant placement and connective tissue graft, or early implant placement, tended to result in less soft tissue regression due to the thicker postoperative facial soft tissue volume.

19.
Int J Implant Dent ; 9(1): 16, 2023 Jun 23.
Artículo en Inglés | MEDLINE | ID: mdl-37351804

RESUMEN

OBJECTIVES: To evaluate how peri-implant hard and soft tissue height (BH, MH) alter after final prostheses placement related to labial hard and soft tissue thickness (BW, MW). MATERIALS AND METHODS: Forty-five platform-switched implants were classified into four groups according to BW and MW: type 1 (thick BW and thick MW), type 2 (thick BW and thin MW), type 3 (thin BW and thick MW), type 4 (thin BW and thin MW). Tissue resorption was evaluated on cone-beam CT images taken at final prostheses placement, at 1-year follow-up, and at 2-year follow-up. Kruskal-Wallis test and post hoc Mann-Whitney test were applied; significance was set to 0.05. RESULTS: BH resorption was 0.13 ± 0.12 mm in type 1, 0.26 ± 0.17 mm in type 2, 0.09 ± 0.09 mm in type 3, 0.94 ± 0.19 mm in type 4. Differences between type 1 and 4, type 2 and 4, and type 3 and 4 were statistically significant (p < 0.001, p = 0.005, p < 0.001, respectively). MH resorption was 0.10 ± 0.09 mm in type 1, 0.36 ± 0.16 mm in type 2, 0.12 ± 0.12 mm in Type 3, 0.79 ± 0.23 mm in type 4. Differences between type 1 and 2, type 1 and 4, type 2 and 3, type 2 and 4 and type 3 and 4 were statistically significant (p < 0.001). CONCLUSIONS: Significantly less BH/MH resorption occurs around implants with thick BW/MW than those with thin BW/MW in 2 years. Implants with thick peri-implant soft tissue resulted in significantly less tissue resorption in second year after final prostheses placement.


Asunto(s)
Implantación Dental Endoósea , Arcada Parcialmente Edéntula , Oseointegración , Estudios Prospectivos , Humanos , Tomografía Computarizada de Haz Cónico , Frenillo Labial/diagnóstico por imagen , Arcada Parcialmente Edéntula/cirugía , Masculino , Femenino , Adulto , Persona de Mediana Edad , Anciano , Implantación Dental Endoósea/efectos adversos
20.
Clin Implant Dent Relat Res ; 25(1): 107-117, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36415012

RESUMEN

BACKGROUND AND PURPOSE: Zirconia abutments have been widely adopted in clinical implant practice. The unique mechanical properties of zirconia may significantly affect the long-term prognosis of implant treatments. The purpose of this study was to investigate the influence of abutment material on implant deformation and fracture resistance of internal conical connection implant-abutment complexes of two diameters after standardized artificial aging. MATERIALS AND METHODS: Thirty original abutments (one-piece titanium, one-piece zirconia, zirconia with alloy base) with two diameters (regular, narrow) were connected to internal conical connection implants and subjected to a standardized artificial aging process consisting of thermal cycling and mechanical cyclic loading. Microcomputed tomography (µCT) scans of implant bodies were performed before and after aging. 3-dimensional images of implant bodies were generated from the µCT scans and aligned for before and after aging to calculate the volumetric deformation amount. Finally, fracture resistance was measured using a mechanical static loading test for the surviving aged and 30 brand-new specimens. RESULTS: All specimens survived artificial aging. No significant difference in implant deformation was found in the regular groups (p = 0.095). In narrow groups, the one-piece zirconia group showed significantly less deformation (p < 0.0001). For fracture resistance, no significant decrease was observed after aging in any group (p > 0.05). One-piece zirconia abutments showed significantly lower strength than the other two materials for both diameters (p < 0.0001). CONCLUSIONS: In the regular diameter system, abutment material had no significant influence on the tested mechanical property degradation after simulated long-term oral use. The mechanical performance of narrow diameter one-piece zirconia abutments differed from the other two materials. For optimal performance, one-piece zirconia abutments should be adopted only in anterior regions.


Asunto(s)
Diseño de Implante Dental-Pilar , Implantes Dentales , Microtomografía por Rayos X , Ensayo de Materiales , Análisis del Estrés Dental , Pilares Dentales , Fracaso de la Restauración Dental , Circonio , Titanio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA