Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros

Banco de datos
Tipo del documento
País de afiliación
Intervalo de año de publicación
1.
Neuromodulation ; 24(1): 86-101, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32865344

RESUMEN

BACKGROUND: Recent studies have highlighted multicolumn spinal cord stimulation (SCS) efficacy, hypothesizing that optimized spatial neural targeting provided by new-generation SCS lead design or its multicolumn programming abilities could represent an opportunity to better address chronic back pain (BP). OBJECTIVE: To compare multicolumn vs. monocolumn programming on clinical outcomes of refractory postoperative chronic BP patients implanted with SCS using multicolumn surgical lead. MATERIALS AND METHODS: Twelve centers included 115 patients in a multicenter, randomized, double-blind, controlled trial. After randomization, leads were programmed using only one or several columns. The primary outcome was change in BP visual analogic scale (VAS) at six months. All patients were then programmed using the full potential of the lead up until 12-months follow-up. RESULTS: At six months, there was no significant difference in clinical outcomes whether the SCS was programmed using a mono or a multicolumn program. At 12 months, in all patients having been receiving multicolumn SCS for at least six months (n = 97), VAS decreases were significant for global pain (45.1%), leg pain (55.8%), and BP (41.5%) compared with baseline (p < 0.0001). CONCLUSION: The ESTIMET study confirms the significant benefit experienced on chronic BP by patients implanted with multicolumn SCS, independently from multicolumn lead programming. These good clinical outcomes might result from the specific architecture of the multicolumn lead, giving the opportunity to select initially the best column on a multicolumn grid and to optimize neural targeting with low-energy requirements. However, involving more columns than one does not appear necessary, once initial spatial targeting of the "sweet spot" has been achieved. Our findings suggest that this spatial concept could also be transposed to cylindrical leads, which have drastically improved their capability to shape the electrical field, and might be combined with temporal resolution using SCS new modalities.


Asunto(s)
Síndrome de Fracaso de la Cirugía Espinal Lumbar , Estimulación de la Médula Espinal , Dolor de Espalda/terapia , Humanos , Dimensión del Dolor , Estudios Prospectivos , Médula Espinal , Resultado del Tratamiento
2.
Clin J Pain ; 24(4): 325-34, 2008 May.
Artículo en Inglés | MEDLINE | ID: mdl-18427231

RESUMEN

BACKGROUND: Spinal cord stimulation is an effective therapy for chronic, neuropathic pain refractory to medication. Use of a rechargeable neurostimulation system (Restore, Medtronic Inc) could provide greater longevity in the treatment of complex pain. However, patients' ability to successfully recharge a neurostimulation system has not yet been demonstrated. PRIMARY OBJECTIVE: Ability of patients to recharge the neurostimulator. SECONDARY OBJECTIVES: Patient and physician satisfaction with the system, pain relief, quality of life, functional status, adverse events. METHODS: Prospective, open-label, multicenter, European study in patients with long-term refractory neuropathic pain. Recharging ability was assessed 1-month postimplant. Patient and physician satisfaction, pain relief, quality of life, and functional status were assessed at scheduled follow-up visits through 12 months. Adverse events were monitored throughout. RESULTS: Primary end point: 100% of patients (n=41) successfully recharged the neurostimulator. Secondary end points at 1 month: 78.6% of patients found recharging easy. At 12 months: physicians were satisfied with the system for 92.7% of patients; pain intensity decreased significantly (P<0.001); mean self-reported pain relief was 62%; 80.5% of patients had more than 50% pain relief; quality of life and functional status improved significantly (P<0.001); 98% of patients would recommend spinal cord stimulation to others. Overall, 41 device-related complications (23 patients) were observed. CONCLUSIONS: Twelve-month experience indicates that the rechargeable neurostimulation system (Restore) was easy to use, with 100% of patients able to recharge successfully. Patient and physician satisfaction was high, with significant improvements in pain, quality of life, and functional status. Complications were comparable to prior experience with this therapy.


Asunto(s)
Terapia por Estimulación Eléctrica/instrumentación , Terapia por Estimulación Eléctrica/métodos , Manejo del Dolor , Satisfacción del Paciente , Adulto , Anciano , Evaluación de la Discapacidad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Dolor/fisiopatología , Dolor/psicología , Dimensión del Dolor , Prótesis e Implantes , Calidad de Vida , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA