Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Más filtros

Banco de datos
País/Región como asunto
Tipo del documento
Intervalo de año de publicación
1.
Echocardiography ; 37(12): 2144-2147, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33084030

RESUMEN

Diagnosis of anomalous origin of the right subclavian artery (AORSA) from the right pulmonary artery (RPA) is usually made using CT, MRI, or invasive angiography. We report a patient diagnosed using transthoracic echocardiography (TTE). A newborn girl prenatally known to have d-TGA presented with cyanosis sparing the right hemithorax and arm. Oxygen saturations on the right hand were persistently higher than on the right ear and other extremities. Repeat TTE using a modified echocardiographic imaging plane allowed for full visualization of the entire subclavian artery course, revealing AORSA from RPA. We discuss further the approach to echocardiographic diagnosis and surgical implications.


Asunto(s)
Arteria Pulmonar , Transposición de los Grandes Vasos , Ecocardiografía , Femenino , Humanos , Recién Nacido , Arteria Pulmonar/diagnóstico por imagen , Arteria Subclavia/diagnóstico por imagen , Transposición de los Grandes Vasos/diagnóstico por imagen , Transposición de los Grandes Vasos/cirugía
2.
Pediatr Cardiol ; 41(8): 1617-1622, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-32715337

RESUMEN

An established echocardiographic (echo) standard for assessing the newborn right ventricle (RV) for hypertrophy has not been thoroughly developed. This is partially due to the RV's complex architecture, which makes quantification of RV mass by echo difficult. Here, we retrospectively evaluate the thickness of the inferior RV wall (iRVWT) by echo in neonates and infants with normal cardiopulmonary physiology. Inferior RVWT was defined at the medial portion of the inferior wall of the RV at the mid-ventricular level, collected from a subxiphoid, short axis view. iRVWT was indexed to body surface area (BSA) to the 0.5 power and normalized to iLVWT to explore the best normalization method. Ninety-eight neonates and 32 infants were included in the final analysis. Mean age for neonates and infants was 2 days and 59 days, respectively. Mean ± SD for neonate and infant end-diastole iRVWT was 2.17 ± 0.35 mm and 1.79 ± 0.28 mm, respectively. There was no residual relationship between the index iRVWT and BSA (r = 0.03, p = NS). In the infant cohort, the iRVWT was significantly lower and iLVWT was significantly higher compared to neonate, consistent with known physiologic changes of RV and LV mass. Thus, iRVWT may serve as a reliable and accurate proxy for RV mass and the parameter warrants further evaluation.


Asunto(s)
Ecocardiografía/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Hipertrofia Ventricular Derecha/diagnóstico por imagen , Femenino , Ventrículos Cardíacos/patología , Humanos , Lactante , Recién Nacido , Masculino , Proyectos Piloto , Estudios Retrospectivos
3.
Pediatr Cardiol ; 40(2): 412-420, 2019 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-30310940

RESUMEN

Quantification of left ventricular (LV) mass by echocardiography has not been validated against the gold standard of cardiac magnetic resonance imaging (CMR) in the pediatric population. The purpose of this study was to compare LV mass by two-dimensional and conventional M-mode echocardiography versus CMR in children. Consecutive CMR studies were paired with echocardiograms and retrospectively analyzed in children age ≤ 16 years (3 days old to 16 years old). Studies performed > 3 months between modalities and single ventricle anatomy were excluded. Unindexed LV mass was calculated using M-mode, area-length (AL), and truncated ellipsoid (TE) methods via echocardiography, and compared to cine stack CMR images. There were 46 patients included in the study (both MRI and echocardiography). Good correlations were observed for LV mass measured by CMR and all echocardiographic methods: M-mode (R = 0.965), AL (R = 0.975), and TE (R = 0.975). There was a significant overestimation using TE echocardiography, by a mean of 10.5 g (95% confidence interval 5.7-15.2 g, p < 0.05). There was no significant over- or underestimation of LV mass observed by M-mode or AL echocardiographic measurements, with tight limits of agreement when compared to CMR (95% confidence interval - 5.2 to 4.4 g and - 1.5 to 6.7 g, respectively). Interobserver agreement was good for each of the echocardiographic measurements, but inferior with M-mode (ICC, 0.89) compared to two-dimensional methods (ICC, 0.97). Echocardiographic estimates of LV mass have good correlation with CMR in children. Performance comparison showed AL echocardiographic method provides the most accurate measurement of LV mass with the best reproducibility compared to other methods.


Asunto(s)
Ecocardiografía/métodos , Ventrículos Cardíacos/diagnóstico por imagen , Imagen por Resonancia Cinemagnética/métodos , Adolescente , Niño , Preescolar , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Estudios Retrospectivos
4.
Pediatr Cardiol ; 37(6): 1028-36, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27041098

RESUMEN

The method of cardiac magnetic resonance (CMR) three-dimensional (3D) image acquisition and post-processing which should be used to create optimal virtual models for 3D printing has not been studied systematically. Patients (n = 19) who had undergone CMR including both 3D balanced steady-state free precession (bSSFP) imaging and contrast-enhanced magnetic resonance angiography (MRA) were retrospectively identified. Post-processing for the creation of virtual 3D models involved using both myocardial (MS) and blood pool (BP) segmentation, resulting in four groups: Group 1-bSSFP/MS, Group 2-bSSFP/BP, Group 3-MRA/MS and Group 4-MRA/BP. The models created were assessed by two raters for overall quality (1-poor; 2-good; 3-excellent) and ability to identify predefined vessels (1-5: superior vena cava, inferior vena cava, main pulmonary artery, ascending aorta and at least one pulmonary vein). A total of 76 virtual models were created from 19 patient CMR datasets. The mean overall quality scores for Raters 1/2 were 1.63 ± 0.50/1.26 ± 0.45 for Group 1, 2.12 ± 0.50/2.26 ± 0.73 for Group 2, 1.74 ± 0.56/1.53 ± 0.61 for Group 3 and 2.26 ± 0.65/2.68 ± 0.48 for Group 4. The numbers of identified vessels for Raters 1/2 were 4.11 ± 1.32/4.05 ± 1.31 for Group 1, 4.90 ± 0.46/4.95 ± 0.23 for Group 2, 4.32 ± 1.00/4.47 ± 0.84 for Group 3 and 4.74 ± 0.56/4.63 ± 0.49 for Group 4. Models created using BP segmentation (Groups 2 and 4) received significantly higher ratings than those created using MS for both overall quality and number of vessels visualized (p < 0.05), regardless of the acquisition technique. There were no significant differences between Groups 1 and 3. The ratings for Raters 1 and 2 had good correlation for overall quality (ICC = 0.63) and excellent correlation for the total number of vessels visualized (ICC = 0.77). The intra-rater reliability was good for Rater A (ICC = 0.65). Three models were successfully printed on desktop 3D printers with good quality and accurate representation of the virtual 3D models. We recommend using BP segmentation with either MRA or bSSFP source datasets to create virtual 3D models for 3D printing. Desktop 3D printers can offer good quality printed models with accurate representation of anatomic detail.


Asunto(s)
Corazón , Humanos , Imagenología Tridimensional , Angiografía por Resonancia Magnética , Impresión Tridimensional , Reproducibilidad de los Resultados
5.
Pediatr Cardiol ; 37(4): 696-703, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26717912

RESUMEN

Cardiac magnetic resonance (CMR) assesses myocardial involvement in myocarditis (MYO). Current techniques are qualitative, subjective, and prone to interpretation error. Feature tracking (FT) analyzes myocardial strain using CMR and has not been examined in MYO. We hypothesize that regional left ventricular (LV) strain is abnormal in MYO. Regional strain by FT was compared to late gadolinium enhancement (LGE) and troponin leak as measures of myocardial involvement. This single-center, retrospective CMR study reviewed patients with clinical MYO and structurally normal hearts who underwent CMR at our institution. Young adults with normal cardiac anatomy, function, and absent LGE served as controls. MYO patients with documented troponin leak and normal global ejection fraction (EF > 50 %) were included in comparison. FT determined regional myocardial peak systolic strain (pkS) in longitudinal and circumferential distributions. T tests compared strain values between cases and controls. Receiver operating characteristic curves determined pkS values with highest sensitivity and specificity for concurrent troponin leak and LGE. FT was performed on 57 patients: 37 MYO and 20 controls. Twenty-eight cases with normal EF, and 20 control patients were included in final analysis. Nearly all cases with normal function demonstrated abnormal regional pkS (27/28, 96 %). Cases had significantly diminished pkS when compared to controls in all regions except the longitudinal 2C distribution. FT-derived longitudinal and circumferential pkS is sensitive and specific in identifying myocardial involvement, namely the presence of troponin leak and LGE. FT may be a useful adjunctive, objective measure of myocardial involvement in patients with MYO and normal LV function.


Asunto(s)
Ventrículos Cardíacos/fisiopatología , Miocarditis/diagnóstico por imagen , Miocardio/patología , Troponina/sangre , Función Ventricular Izquierda , Adolescente , Estudios de Casos y Controles , Medios de Contraste/química , Ecocardiografía , Femenino , Gadolinio DTPA/química , Humanos , Modelos Logísticos , Imagen por Resonancia Cinemagnética , Masculino , Estudios Retrospectivos , Sensibilidad y Especificidad , Sístole , Adulto Joven
6.
Pediatr Cardiol ; 37(1): 90-8, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26254102

RESUMEN

Our goal was to construct three-dimensional (3D) virtual models to allow simultaneous visualization of the ventricles, ventricular septal defect (VSD) and great arteries in patients with complex intracardiac anatomy to aid in surgical planning. We also sought to correlate measurements from the source cardiac magnetic resonance (CMR) image dataset and the 3D model. Complicated ventriculo-arterial relationships in patients with complex conotruncal malformations make preoperative assessment of possible repair pathways difficult. Patients were chosen with double outlet right ventricle for the complexity of intracardiac anatomy and potential for better delineation of anatomic spatial relationships. Virtual 3D models were generated from CMR 3D datasets. Measurements were made on the source CMR as well as the 3D model for the following structures: aortic diameter in orthogonal planes, VSD diameter in orthogonal planes and long axis of right ventricle. A total of six patients were identified for inclusion. The path from the ventricles to each respective outflow tract and the location of the VSD with respect to each great vessel was visualized clearly in all patients. Measurements on the virtual model showed excellent correlation with the source CMR when all measurements were included by Pearson coefficient, r = 0.99 as well as for each individual structure. Construction of virtual 3D models in patients with complex conotruncal defects from 3D CMR datasets allows for simultaneous visualization of anatomic relationships relevant for surgical repair. The availability of these models may allow for a more informed preoperative evaluation in these patients.


Asunto(s)
Ventrículo Derecho con Doble Salida/diagnóstico , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Niño , Preescolar , Simulación por Computador , Ventrículo Derecho con Doble Salida/complicaciones , Corazón , Humanos , Estudios Retrospectivos
7.
J Cardiovasc Magn Reson ; 17: 39, 2015 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-26004027

RESUMEN

BACKGROUND: Open cardiovascular magnetic resonance (CMR) scanners offer the potential for imaging patients with claustrophobia or large body size, but at a lower 1.0 Tesla magnetic field. This study aimed to evaluate the efficacy of open CMR for evaluation of pediatric and congenital heart disease. METHODS: This retrospective, cross-sectional study included all patients ≤18 years old or with congenital heart disease who underwent CMR on an open 1.0 Tesla scanner at two centers from 2012-2014. Indications for CMR and clinical questions were extracted from the medical record. Studies were qualitatively graded for image quality and diagnostic utility. In a subset of 25 patients, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were compared to size- and diagnosis-matched patients with CMR on a 1.5 Tesla scanner. RESULTS: A total of 65 patients (median 17.3 years old, 60% male) were included. Congenital heart disease was present in 32 (50%), with tetralogy of Fallot and bicuspid aortic valve the most common diagnoses. Open CMR was used due to scheduling/equipment issues in 51 (80%), claustrophobia in 7 (11%), and patient size in 3 (5%); 4 patients with claustrophobia had failed CMR on a different scanner, but completed the study on open CMR without sedation. All patients had good or excellent image quality on black blood, phase contrast, magnetic resonance angiography, and late gadolinium enhancement imaging. There was below average image quality in 3/63 (5%) patients with cine images, and 4/15 (27%) patients with coronary artery imaging. SNR and CNR were decreased in cine and magnetic resonance angiography images compared to 1.5 Tesla. The clinical question was answered adequately in all but 2 patients; 1 patient with a Fontan had artifact from an embolization coil limiting RV volume analysis, and in 1 patient the right coronary artery origin was not well seen. CONCLUSIONS: Open 1.0 Tesla scanners can effectively evaluate pediatric and congenital heart disease, including patients with claustrophobia and larger body size. Despite minor artifacts and differences in SNR and CNR, the majority of clinical questions can be answered adequately, with some limitations with coronary artery imaging. Further evaluation is necessary to optimize protocols and image quality.


Asunto(s)
Vasos Coronarios/patología , Cardiopatías Congénitas/patología , Angiografía por Resonancia Magnética/instrumentación , Imagen por Resonancia Cinemagnética/instrumentación , Miocardio/patología , Adolescente , Adulto , Factores de Edad , Artefactos , Tamaño Corporal , Niño , Preescolar , Estudios Transversales , Diseño de Equipo , Femenino , Humanos , Interpretación de Imagen Asistida por Computador , Angiografía por Resonancia Magnética/efectos adversos , Imagen por Resonancia Cinemagnética/efectos adversos , Masculino , Michigan , Persona de Mediana Edad , New York , Variaciones Dependientes del Observador , Trastornos Fóbicos/etiología , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Relación Señal-Ruido , Adulto Joven
8.
Pediatr Cardiol ; 36(5): 950-9, 2015 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25617227

RESUMEN

The presence of myocardial late gadolinium enhancement (LGE) by cardiac magnetic resonance (CMR) imaging in concert with electrocardiography and elevated biomarkers helps support the diagnosis of acute myocarditis. Two-dimensional echocardiography is limited to global and qualitative regional function assessment and may not contribute to the diagnosis, especially in the presence of normal LV systolic function. Two-dimensional speckle-tracking (2D-STE)-derived segmental peak systolic (pkS) longitudinal strain (LS) may identify segmental myocardial involvement in myocarditis. We sought to identify an association between segmental pkS, LGE, and troponin levels in patients with myocarditis. Retrospective analysis of myocardial segmental function by 2D-STE segmental strain was compared to the presence of LGE and admission peak troponin levels in patients with acute myocarditis and preserved global LV systolic function. American Heart Association 17-segment model was used for comparison between imaging modalities. Global function was assessed by m-mode-derived shortening fraction (SF). Descriptive statistics and regression analysis were utilized. Forty-four CMRs performed to evaluate for myocarditis were identified. Of the 44, 10 patients, median age 17.5 years (14-18.5 years) and median SF 35 % (28-44 %), had paired CMR and 2D-STE data for analysis, and 161/170 segments could be analyzed by both methods for comparison. PkS LS was decreased in 51 % of segments that were positive for LGE with average pkS of -14.7 %. Segmental pkS LS abnormalities were present in all but one patient who had abnormal pkS circumferential strain. Global pkS LS was decreased in patients with myocarditis. There is a moderate correlation between decreased pkS LS and the presence of LGE by CMR, 2D-STE for myocardial involvement in acute myocarditis can serve as an useful noninvasive adjunct to the existing tests used for the diagnosis of acute myocarditis and might have a role in prognostication.


Asunto(s)
Ecocardiografía/métodos , Imagen por Resonancia Cinemagnética/métodos , Miocarditis/diagnóstico , Miocardio/patología , Función Ventricular Izquierda , Adolescente , Medios de Contraste , Femenino , Gadolinio DTPA , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Miocarditis/diagnóstico por imagen , Miocarditis/patología , Estudios Retrospectivos , Adulto Joven
9.
Echocardiography ; 30(6): 713-8, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23311530

RESUMEN

Thoracic aortic disease is a known cause of aortic dilatation and poses significant risk of aortic dissection and rupture. Serial assessment of aortic root dimensions is traditionally performed using echocardiography, which is limited with older age and following surgery, due to poor acoustic windows. Although diastolic measurements are utilized as standard practice in decision making of adult aortopathy, systolic diameters are utilized in pediatric practice. Three-dimensional steady-state free precision (3D-SSFP) has shown promise as an alternate method for providing accurate and reproducible aortic measurements. The agreement between proximal aorta measurements by diastolic 3D-SSFP and echocardiography (both systole and diastole) was examined in 40 subjects. The maximum inner diameters at aortic annulus, root and sinotubular junction demonstrated excellent agreement between 3D-SSFP and echocardiography for all the 3 levels. The best agreement was observed for diastolic root dimensions with a mean difference of +0.01 cm, limits of agreement being -0.26 to +0.28 cm. Three D-SSFP can be used interchangeably with echocardiography in the serial assessment of the aortic root size. Careful attention to obtain an imaging plane utilizing 3D multiplanar reformatting is critical to maximize the agreement between the two imaging modalities.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Aorta Torácica/patología , Enfermedades de la Aorta/diagnóstico , Imagenología Tridimensional/métodos , Imagen por Resonancia Cinemagnética/métodos , Adolescente , Adulto , Niño , Preescolar , Ecocardiografía Tridimensional , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Adulto Joven
10.
Echocardiography ; 30(2): 196-202, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23311460

RESUMEN

BACKGROUND: Decreased right ventricular (RV) ejection fraction (EF) increases morbidity in repaired tetralogy of Fallot (rToF). Cardiac magnetic resonance (CMR) is the accepted reference standard for RV EF measurement. There are no established color Doppler tissue imaging (cDTI) values that identify decreased RV EF in rToF. We sought to assess accuracy of cDTI myocardial deformation and velocity indices in predicting CMR-derived RV EF. METHODS: Retrospective evaluation of CMR and echocardiography studies performed on the same day. cDTI-derived peak systolic velocity (pkS), isovolumic acceleration (IVA) of the tricuspid valve annulus, strain (ε) and strain rate (SR) of the RV free wall, adjusted for age, volume and pressure overload were used to compute RV EF. The probability of correctly classifying CMR measured RV EF <45% was estimated by logistic regression analysis. The accuracy of the model was tested on 10 prospective patients. RESULTS: Sixty matched echocardiographic and CMR studies were analyzed. None of the individual cDTI parameters could reliably identify patients with CMR-derived decreased RV EF. However, when adjusted for age in a logistic model: Y = -0.5 - 0.07 × age + 0.016 × Îµ + 0.46 × pkS, where Y is the logit (log odds), patients with RV EF <45% were identified with 86% sensitivity, 93.5% specificity. Prospective application of this model correctly identified all subjects with RV EF <45%. CONCLUSION: The age-adjusted logistic model and not individual parameters, derived from cDTI-derived pkS, and ε can reliably identify patients with decreased RV EF <45%.


Asunto(s)
Ecocardiografía Doppler/métodos , Imagen por Resonancia Cinemagnética/métodos , Miocardio/patología , Tetralogía de Fallot/diagnóstico por imagen , Función Ventricular Derecha , Estudios Transversales , Estudios de Seguimiento , Humanos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Volumen Sistólico , Tetralogía de Fallot/fisiopatología , Tetralogía de Fallot/cirugía
11.
Pediatr Cardiol ; 34(3): 492-7, 2013 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-22923009

RESUMEN

Accurate assessment of the proximal thoracic vasculature in infants and children with congenital heart disease (CHD) is vital for deciding the appropriate surgical or interventional procedure and predicting outcomes. This information usually is obtained by transthoracic echocardiography (TTE). Contrast-enhanced magnetic resonance angiography (CE-MRA) frequently is used to obtain diagnostic data when the image quality by TTE is limited. Calculation of z-scores for measurements obtained by CE-MRA in this population currently is not possible due to the lack of normative data. A reasonable agreement between vessel dimensions by CE-MRA and TTE will allow the use of TTE-based z-scores on measurements from CE-MRA. This study examines the accuracy and agreement of proximal thoracic vascular measurements obtained by CE-MRA versus TTE. Infants and children younger than 3 years with CHD who had a CE-MRA between August 2006 and May 2011 were retrospectively identified. Main and branch pulmonary arteries, ascending aorta, distal transverse arch, and aortic isthmus were measured from CE-MRA and TTE in analogous imaging planes and locations by two investigators blinded to each other. The study enrolled 35 subjects with CHD. The median age was 129 days (range, 0-1077 days), and the median weight was 5.8 kg (range, 2.16-17 kg). The median interval between the two imaging methods was 9 days (range, 0-60 days). Data analysis was performed with 129 of the 210 possible paired measurements. The remaining 81 paired measurements could not be performed due to inaccurate visualization of vessel borders or an unavailable imaging plane from TTE, CE-MRA, or both. The range of vessel sizes measured from 2.8 to 23.4 mm. There was excellent correlation between CE-MRA and TTE (r = 0.94, p < 0.001). The mean difference between the measurements was -0.1 ± 1.2 mm, and the limits of agreement were -2.5 to 2.3 mm. Proximal thoracic vascular measurements obtained by CE-MRA and TTE in infants and children with CHD have a strong correlation. The agreement between these two imaging methods is adequate. Until normative data for vessel size measurements obtained from CE-MRA are available for this population, TTE-based z-scores can be applied to the measurements obtained by CE-MRA.


Asunto(s)
Ecocardiografía/métodos , Cardiopatías Congénitas/diagnóstico , Imagenología Tridimensional , Angiografía por Resonancia Magnética/métodos , Intensificación de Imagen Radiográfica , Factores de Edad , Aorta Torácica/patología , Preescolar , Estudios de Cohortes , Medios de Contraste , Femenino , Humanos , Lactante , Masculino , Arteria Pulmonar/patología , Reproducibilidad de los Resultados , Estudios Retrospectivos , Factores de Riesgo
12.
Pediatr Cardiol ; 34(6): 1314-20, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23389098

RESUMEN

This study aimed to determine whether quantification of subpulmonary stenosis (SPS) in tetralogy of Fallot (TOF) in the second-trimester fetus can predict postnatal clinical outcome measured by pulmonary valve size and/or timing or type of intervention. The study retrospectively identified fetuses with TOF from 1998 to 2010 diagnosed at 26 weeks gestation or earlier. The data evaluated included pre- and postnatal pulmonary valve z-scores (PVZ). To quantify fetal SPS, the authors created a novel index, the SPS/DAO ratio, a ratio of the minimum infundibular diameter to the descending aorta diameter (DAO). Multiple linear regression was used to predict postnatal PVZ from prenatally determined parameters, including SPS/DAO. Fetal parameters were analyzed by logistic regression for association with postnatal outcomes, namely, timing of surgery (<1 month), used as a surrogate for severity, and type of surgery [transannular patch (TAP) vs valve sparing surgery]. A total of 23 fetuses met the inclusion criteria. The mean gestational age was 21.8 ± 1.9 weeks (range, 16.6-25.4 weeks). There was excellent correlation between predicted and measured PVZ (r = 0.82; p < 0.0001) using the following derived equation: -3.68 + (0.91 × prenatal PVZ) - (4.44 × SPS/DAO) - 3.19 (prenatal PVZ × SPS/DAO). An SPS/DAO value lower than 0.5 had 100 % sensitivity and 56 % specificity for repair before the age of 1 month, and a value lower than 0.47 had 100 % sensitivity and 75 % specificity for TAP repair. Prenatal PVZ and the SPS/DAO ratio at 26 weeks gestation or earlier can reliably predict postnatal PVZ in fetuses with TOF. Quantification of SPS with the SPS/DAO ratio identifies patients who may require early intervention secondary to disease severity and may predict the type of repair, thereby influencing prenatal counseling.


Asunto(s)
Enfermedades Fetales/diagnóstico por imagen , Estenosis Subvalvular Pulmonar/diagnóstico por imagen , Tetralogía de Fallot/diagnóstico por imagen , Ultrasonografía Prenatal/métodos , Diagnóstico Diferencial , Femenino , Estudios de Seguimiento , Edad Gestacional , Humanos , Valor Predictivo de las Pruebas , Embarazo , Segundo Trimestre del Embarazo , Pronóstico , Estudios Retrospectivos
13.
Cardiol Young ; 23(3): 409-15, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-22914442

RESUMEN

INTRODUCTION: The prevalence of right ventricular dysfunction in idiopathic dilated cardiomyopathy is incompletely studied in children. Furthermore, right ventricular function may signal worse outcomes. We evaluated recently published right ventricular function echocardiographic indices in identifying dysfunction in children with idiopathic dilated cardiomyopathy and the impact of right ventricular dysfunction on long-term prognosis. METHODS: A retrospective database review of right ventricular function indices in 30 patients with idiopathic dilated cardiomyopathy was compared with 60 age- and sex-matched controls from January, 2001 until December, 2010. Right ventricular function was assessed by Doppler tissue peak systolic S', early and late diastolic E' and A' waves and isovolumic acceleration at the tricuspid valve annulus; pulsed wave Doppler tricuspid valve inflow E and A waves; right ventricular myocardial performance index; tricuspid annular plane systolic excursion; right ventricular fractional area change. RESULTS: Right ventricular systolic and diastolic function in idiopathic dilated cardiomyopathy was significantly impaired. All measured indices except for isovolumic acceleration and fractional area change were significantly reduced, with a p-value less than 0.05. There was no right ventricular index predictive of death or transplantation. Patients with poor outcome were significantly more likely to need inotropic support (p-value equal to 0.018), be placed on a ventricular assist device (p equal to 0.005), and have a worse left ventricular ejection fraction z-score (p-value equal to 0.002). CONCLUSION: Right ventricular dysfunction is under-recognised in children presenting with idiopathic dilated cardiomyopathy. The need for clinical circulatory support and left ventricular ejection fraction z-score less than minus 8 were primary determinants of outcome, independent of the degree of derangement in right ventricular function.


Asunto(s)
Cardiomiopatía Dilatada/fisiopatología , Disfunción Ventricular Derecha/fisiopatología , Adolescente , Cardiomiopatía Dilatada/diagnóstico por imagen , Estudios de Casos y Controles , Niño , Preescolar , Ecocardiografía Doppler , Femenino , Humanos , Lactante , Masculino , Pronóstico , Estudios Retrospectivos , Disfunción Ventricular Derecha/diagnóstico por imagen
14.
Pediatr Radiol ; 41(8): 1000-7, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21437608

RESUMEN

BACKGROUND: The measurement error for right ventricular (RV) size and function assessed by cardiac MRI (CMRI) in congenital heart disease has not been fully characterized. As CMRI parameters are being increasingly utilized to make clinical decisions, defining error in the clinical setting is critical. OBJECTIVE: This investigation examines the repeatability of CMRI for RV size and function. MATERIALS AND METHODS: Forty consecutive people with congenital heart disease involving the RV were retrospectively identified. Contouring of RV volumes was performed by two expert CMRI clinicians. The coefficient of variability and repeatability coefficients were calculated. Repeatability coefficients were multiplied by the mean value for each group studied to define a threshold beyond which measurement error was unlikely to be responsible. RESULTS: The variability for indexed RV end-diastolic volume = 3.2% and 3.3% for intra- and interobserver comparisons, respectively. The repeatability coefficients were 13.2% and 14.9% for intra- and interobserver comparisons, which yielded threshold values of 15.1 ml/m^2 and 20.2 ml/m^2, respectively. For RV ejection fraction (EF), the repeatability coefficients for intra- and interobserver comparisons were 5.0% and 6.0%, which resulted in threshold values of 2.6 EF% and 3.0 EF%. CONCLUSION: The threshold values generated can be used during serial assessment of RV size and function.


Asunto(s)
Cardiopatías Congénitas/patología , Ventrículos Cardíacos/patología , Imagen por Resonancia Magnética/métodos , Disfunción Ventricular Derecha/patología , Adolescente , Adulto , Niño , Femenino , Corazón , Cardiopatías Congénitas/complicaciones , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Tamaño de los Órganos , Reproducibilidad de los Resultados , Estudios Retrospectivos , Volumen Sistólico , Disfunción Ventricular Derecha/complicaciones , Adulto Joven
15.
Pediatr Radiol ; 41(12): 1526-35, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-22127684

RESUMEN

Imaging of the coronary arteries is an important part of the evaluation of children with congenital heart disease and isolated congenital coronary artery anomalies. Echocardiography remains the main imaging modality and is complemented by MRI and CT angiography in the older or difficult-to-image child. We review echocardiography, MRI, and CT angiography for coronary artery imaging, with emphasis on techniques. The clinical implications of isolated congenital coronary artery anomalies are also addressed, along with a discussion about the current consensus on optimal management of these anomalies.


Asunto(s)
Angiografía Coronaria/métodos , Anomalías de los Vasos Coronarios/diagnóstico , Vasos Coronarios/patología , Angiografía por Resonancia Magnética/métodos , Tomografía Computarizada por Rayos X/métodos , Humanos
16.
Pediatr Cardiol ; 32(8): 1128-31, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21512787

RESUMEN

The hemodynamics of isolated large ventricular septal defect with an intact atrial septum results in greater mitral valve (MV) annular dilation and an increased incidence of mitral regurgitation (MR). MR will resolve in most patients after surgical VSD closure alone without MV repair.


Asunto(s)
Tabiques Cardíacos/patología , Insuficiencia de la Válvula Mitral/epidemiología , Válvula Mitral/patología , Dilatación Patológica , Femenino , Atrios Cardíacos , Defectos del Tabique Interventricular/epidemiología , Hemodinámica , Humanos , Lactante , Recién Nacido , Masculino
17.
JTCVS Tech ; 8: 116-123, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34401829

RESUMEN

OBJECTIVE: Although the right ventricle (RV) to pulmonary artery conduit in stage 1 Norwood operation results in improved interstage survival, the long-term effects of the ventriculotomy used in the traditional technique remain a concern. The periscopic technique (PT) of RV to pulmonary artery conduit placement has been described as an alternative technique to minimize RV injury. A retrospective study was performed to compare the effects of traditional technique and PT on ventricular function following Norwood operation. METHODS: A retrospective study of all patients who underwent Norwood operation from 2012 to 2019 was performed. Patients with baseline RV dysfunction and significant tricuspid valve regurgitation were excluded. Prestage 2 echocardiograms were reviewed by a blinded experienced imager for quantification of RV function (sinus and infundibular RV fractional area change) as well as for regional conduit site wall dysfunction (normal or abnormal, including hypokinesia, akinesia, or dyskinesia). Wilcoxon rank-sum tests were used to assess differences in RV infundibular and RV sinus ejection fraction and the Fisher exact test was used to assess differences in regional wall dysfunction. RESULTS: Twenty-two patients met inclusion criteria. Eight underwent traditional technique and 14 underwent PT. Median infundibular RV fractional area change was 49% and 37% (P = .02) and sinus RV fractional area change was 50% and 41% for PT and traditional technique (P = .007) respectively. Similarly qualitative regional RV wall function was better preserved in PT (P = .002). CONCLUSIONS: The PT for RV to pulmonary artery conduit in Norwood operation results in better preservation of early RV global and regional systolic function. Whether or not this benefit translates to improved clinical outcome still needs to be studied.

18.
Echocardiography ; 27(6): 691-5, 2010 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-20412269

RESUMEN

INTRODUCTION: Left ventricular end-diastolic volume (LVEDV) calculation is important in decision making in children with congenital heart disease (CHD). This study examined the accuracy of LVEDV calculation by the formula: 5/6 x area x length ("bullet" method), by comparing echocardiographic (ECHO) LVEDV against cardiac magnetic resonance (CMR). METHODS: ECHO and CMR data from 72 consecutive subjects with CHD < or =10 years of age were retrospectively reviewed. Exclusion criteria included: >3 months between examinations; unavailable or poor-quality images. Subxiphoid short- and long-axis echocardiographic images were analyzed. Bullet LVEDV was compared to CMR volumes. RESULTS: Seventeen subjects (median age 5.5 years, range 1-10 years) comprised the study group. ECHO and CMR LVEDV showed an excellent correlation (r = 0.97) and a good agreement with a mean difference (limits of agreement) of -1.0 mL (-13.9 to 11.9 mL). CONCLUSIONS: Subxiphoid echocardiographic bullet method of measuring LVEDV shows a good agreement with CMR obtained LV size in young children.


Asunto(s)
Algoritmos , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/patología , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Niño , Preescolar , Femenino , Humanos , Aumento de la Imagen/métodos , Lactante , Masculino , Tamaño de los Órganos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Ultrasonografía
19.
Am J Cardiol ; 100(4): 715-21, 2007 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-17697835

RESUMEN

This study evaluated the quality of the visualization of extracardiac thoracic vessels by magnetic resonance angiography (MRA) in young infants with congenital heart disease. Echocardiography is often sufficient in evaluating CHD in young infants. Cardiac catheterization is needed in some instances to evaluate extracardiac thoracic vessels. Extracardiac thoracic vessels can be accurately evaluated using MRA in adults and older children, but image quality in small infants may be limited. Twenty-nine magnetic resonance angiographic scans were performed at a single institution on 28 infants aged <3 months (median 6 days, range 1 to 90 days) with complex CHD in whom imaging was inconclusive by echocardiography. A blinded observer at a different institution graded (from 0 to 3) the quality of the visualization of the main, branch, lobar, and second-generation pulmonary arteries; lobar pulmonary veins; aortopulmonary collaterals; vena cavae; thoracic aorta and its branches; patent ductus arteriosus; and visceral sidedness. The results of MRA were compared with those of x-ray angiography and surgical inspection, when available. The mean image quality grade was >2 for all structures except the second-generation pulmonary arterial branches, for which it was 2. The median total scan duration was 9 minutes (range 3 to 46). Findings were concordant with surgical inspection (n = 25) and cardiac catheterization (n = 8) in all subjects. There were no complications. In conclusion, MRA is excellent for the visualization of extracardiac thoracic vessels in young infants with CHD and can be used as an alternative to cardiac catheterization when echocardiography is inconclusive.


Asunto(s)
Aorta Torácica/patología , Cardiopatías Congénitas/diagnóstico , Angiografía por Resonancia Magnética , Arteria Pulmonar/patología , Venas Pulmonares/patología , Diagnóstico Diferencial , Estudios de Seguimiento , Humanos , Lactante , Recién Nacido , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Estudios Retrospectivos , Índice de Severidad de la Enfermedad
20.
Circulation ; 111(5): 622-8, 2005 Feb 08.
Artículo en Inglés | MEDLINE | ID: mdl-15699283

RESUMEN

BACKGROUND: MRI is increasingly used for anatomic assessment of aortic coarctation (CoA), but its ability to predict the transcatheter pressure gradient, considered the reference standard for hemodynamic severity, has not been studied in detail. This study evaluated the ability of MRI to distinguish between mild versus moderate and severe CoA as determined by cardiac catheterization. METHODS AND RESULTS: The clinical, MRI, and catheterization data of 31 subjects referred for assessment of native or recurrent CoA were reviewed retrospectively. Patients were divided into 2 groups on the basis of peak coarctation gradient by catheterization: <20 mm Hg (n=12) and > or =20 mm Hg (n=19). Patients with cardiac index <2.2 L x min(-1) x m(-2) by catheterization were excluded. By logistic regression analysis, the following variables simultaneously predicted coarctation gradient > or =20 mm Hg: (1) smallest aortic cross-sectional area (adjusted for body surface area) measured by planimetry from gadolinium-enhanced 3D magnetic resonance angiography (OR 1.71 for 10 mm2/m2 decrease, P=0.005) and (2) heart rate-corrected mean flow deceleration in the descending aorta measured by phase-velocity cine MRI (OR 1.68 for 100 mL/s(1.5) increase, P=0.018). For the combination of these variables, a predicted probability >0.38 had 95% sensitivity, 82% specificity, 90% positive and negative predictive values, and an area under the receiver-operator characteristics curve of 0.938. In a subsequent validation study, the prediction model correctly classified 9 of 10 patients, with no false-negatives. CONCLUSIONS: The combination of anatomic and flow data obtained by MRI provides a sensitive and specific test for predicting catheterization gradient > or =20 mm Hg.


Asunto(s)
Coartación Aórtica/diagnóstico , Angiografía por Resonancia Magnética , Adolescente , Aorta/patología , Cateterismo Cardíaco , Niño , Preescolar , Humanos , Lactante , Imagen por Resonancia Cinemagnética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA